Loading...
HomeMy WebLinkAboutExtremem Metal 5V 9/2/20 revision8/28/2020 Florida Building Code Online Professional Regulation 99 ill 1 BCIs Home 4 Log In it User Registration f Hot Topics Submit Surcharge Stats & Facts i Publicationsr Contact Us j BCIS Site Maps ; Links k Search jr .t °� Product Approval . USER: Public User d b Of r Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL17022-R7 Application Type Revision Code Version 2017 Application Status Approved Comments 08/18/2017v, date reapply 08/21/17 Archived Product Manufacturer Extreme Metal Fabricators, LLC Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 flvalidation@yahoo.com Authorized Signature Richard McKuhen flvalidation@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 richard@emfab.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the LOCKE BOWDEN Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R. Priest, P.E. Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Standard TAS 125 U L 1897 UL 580 Year 2003 2012 2006 Sections from the Code https://www.floddabuilding.org/pr/pr app_Otl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 1/3 8/28/2020 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 08/18/2017 Date Validated 08/25/2017 Date Pending FBC Approval 08/28/2017 Date Approved 10/10/2017 Summary of Products s _ FL # Model, Number or Name Description 17022.1 1 - "5V Crimp" (R6) 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.1 5 V CRIMP ssrpdf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions. Install the assembly in compliance with the installation method listed in FL17022 R7 AE FL 17022.1 5 V CRIMP ssrpdf Created by Independent Third Party: Yes { this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.2 2 - "5V Crimp" (116) 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssrpdf Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions.Install the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssrpdf Created by Independent Third Party: Yes I assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.3 3 - "1.5" Mechanical Seam" (115) 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.3 1.5 MECHANICAL Approved for use outside HVHZ: Yes seam 24ga ssrpdf Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes Other! Refer to evaluation report for conditions and limitations Evaluation Reports of use. Install the assembly in compliance with the installation FL17022 R7 AE FL 17022.3 1.5 MECHANICAL method listed in this report and applicable code sections of seam 24ga ssrpdf FBC. Refer to manufacturer's installation instructions. Created by Independent Third Party: Yes 17022.4 4 - "1.5" Mechanical Seam" (115) 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof 1 panel mechanically attached to 15/32" plywood or Wood Deck with clips and fasteners. Limits of Use Approved for use in HVHZ: No Installation Instructions FL17022 R7 II FL 17022.4 MECHANCIAL SEAM ( Approved for use outside HVHZ: Yes ALUMINUM ssr.pd i Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports of use. Install the assembly in compliance with the installation FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM method listed in this report and applicable code sections of ALUMINUM ssrpdf FBC. Refer to manufacturer's installation instructions. - Created by Independent Third Party: Yes �— - 17022.5 5 -� 1 in. Nail Strip" (R5) 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Limits of Use { { Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Installation Instructions FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssrpdf Verified By: Locke Bowden, R E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssrpdf Created by Independent Third Party: Yes j https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3a 2/3 8/28/2020 Florida Building Code Online method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. j 17022.6 16 - "1 in. Nail Strip" (115) 1" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to attached to 15/32' plywood or Wood Deck with fasteners, Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. Installation Instructions FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.pdf Created by Independent Third Party: Yes 17022.7 7 - "1.5 in. Nail Strip" (R5) 1.5" rib height, 19" wide, 26 gauge steel, standing seam roof I panel mechanically attached to 15/32" plywood or wood deck i with fasteners. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.8 18 - "EMAX Rib" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.9 19 - " PBR MAX" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. Installation Instructions FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.pdf Created by Independent Third Party: Yes 29 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Installation Instructions FL17022 R7 II FL 177022.8 EMAX Rib ssr.pd Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 177022.8 EMAX Rib ssr.pd Created by Independent Third Party: Yes 26 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Installation Instructions FL17022 R7 II FL 17022.9 PBR RIB ssr.pdf Verified By: Locke Bowden, RE, 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.9 PBR RIB ssr.pdf Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road,. Tallahassee FL 32399 Phone: 850-487-1824 The Skate of Florida is an AA/EEO employer, CopyLght 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: cLfecY Credit Card Safe https://www.floddabuilding.org/pr/pr app_otl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 3/3 Palm City, Fl. 34990 Compliant with Florida Building Code 2017 (6th ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec.1507.4.2 Yield strength: 50 ksi min., Attached to min.15/32" plywood or Wood Deck w/ min. 0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. Chance 2500 .9. Slope: Shall be in compliance with FBC Sec. 1507. See Fastener attachment specifications above Install Details: Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4 DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF -ROW SPACING 16" o.c. 16" o.c. 8" o.c. 6" o.c. FASTENER SPACING (ALONG Panel width) 12" o.c. 12" o.c. 12" ax. 12" o.c. FASTENER SIZE #9 #10 #10 #10 Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527 UL 580-06 & 1897-041 Test Report 035893.01-450-18 05/02/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897--04 is equivalent to test standard UL 1897-1 *Design pressure margin of safety 2r1 Locke Bowden, P.E. does not have, not will acquire a financial in4t �a +cg rj�►��cturing or distributing products under this evaluation. Locke Bowden, P.E. is not owned, operated, or controlled by alfy coniparN;)n-A8ifa$turer, or distributing products under this fXT'r- _;7/7 *"'�h� •.fit ��?I��� °°'�,}, FL17O22.1 5V Crimp (26GA Steel), 24"' Wide Roof Panel - Details Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. Deck: 15/32" or greater Plywood, or Wood plank 24- • 12'° QP rl3id4�STRIATIONS Panel Profile Nominal 12" Nominal 12" O.C. O.C. Fasten #9 x 1-1/2" Min. or #10 x 1-1/2" Min. per Table "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Width Panel Refer to Table "A" for Spacing Along Panel Overlap Length Deck-15/32" or greater Plywood, or - Wood plank 8/28/2020 Florida Building Code Online sustnelss• Professional rA BCIS Home I Log In User Registration Hot Topics Submit Surcharge Stats & Facts 'i Publications ( Contact Us i BCIS Site Map d Links Search F1 rid t' Product Approval � or USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL11602-R10 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Owens Corning Roofing and Asphalt, LLC Address/Phone/Email One Owens Corning Parkway Toledo, OH 43645 (740)321-6345 Greg.Keeler@owenscorning.com Authorized Signature Keeler Greg Greg.Keeler@owenscorning.com Technical Representative Greg Keeler Address/Phone/Email 2790 Columbus Road Granville, OH 43023 (740) 321-6345 greg.keeler@owenscorning.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 12/31/2020 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL11602 Rt0 COI 2019 01 COI NT MINEN,p-df Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM D226 (physicals) 2009 ASTM D4798 2011 FRSA/TRI April 2012 2012 TAS 117(B) 1995 UL1897 2012 Equivalence of Product Standards Certified By https://www.floNdabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2f'rrZeHYB7UCe5KMr%2f$MfWgra38u9whFr5gP6KA%3d%3d 1/2 8/28/2020 Florida Building Code Online Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/17/2019 Date Validated 10/17/2019 Date Pending FBC Approval 10/20/2019 Date Approved 12/10/2019 Summary of Products I i FL # Model, Number or Name Description 11602.1 Titanium Roof Underlayments Limits of Use Synthetic sheet -type roof underlayments Installation Instructions Approved for use in HVHZ: No FL11602 R10 II 2019 10 FINAL ER FL11602-R10.pdf Approved for use outside HVHZ: Yes Verified By: Robert Nieminen PE-59166 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-45 Evaluation Reports Other: 1.) The design pressure noted herein pertains to use of FL11602 R10 AE 2019 10 FINAL ER FL11602-R10.pLlf a specific underlayment system beneath foam -on tile sytsems. Created by Independent Third Party: Yes Refer to ER Section 5.6.3 for details. 2.) Refer to ER Sections 5 and 6 for other Limits of Use. Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. ,CSRyri ht 2007-2013 State of Florida.:: Pri y Statement :: Accessibility. Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 45S, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: rM FWW 7 ® ¢Cteck E Credit Card Safe https://www.loddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2frrZeHYB7UCe5KMr%2fsMfWgra38u9whFr5gP6KA%3d%3d 2/2