HomeMy WebLinkAboutExtremem Metal 5V 9/2/20 revision8/28/2020 Florida Building Code Online
Professional Regulation
99 ill 1
BCIs Home 4 Log In it User Registration f Hot Topics Submit Surcharge Stats & Facts i Publicationsr Contact Us j BCIS Site Maps ; Links k Search
jr .t °� Product Approval
. USER: Public User
d b Of r
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL17022-R7
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments 08/18/2017v, date reapply 08/21/17
Archived
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
flvalidation@yahoo.com
Authorized Signature Richard McKuhen
flvalidation@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
richard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the LOCKE BOWDEN
Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Standard
TAS 125
U L 1897
UL 580
Year
2003
2012
2006
Sections from the Code
https://www.floddabuilding.org/pr/pr app_Otl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 1/3
8/28/2020 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted
08/18/2017
Date Validated
08/25/2017
Date Pending FBC Approval
08/28/2017
Date Approved
10/10/2017
Summary of Products
s _
FL #
Model, Number or Name
Description
17022.1
1 - "5V Crimp" (R6)
26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel
mechanically attached to 15/32" plywood or Wood Deck with
fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.1 5 V CRIMP ssrpdf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions. Install the
assembly in compliance with the installation method listed in
FL17022 R7 AE FL 17022.1 5 V CRIMP ssrpdf
Created by Independent Third Party: Yes
{ this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.2
2 - "5V Crimp" (116)
0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel,
mechanically attached to 15/32" plywood or Wood Deck with
exposed fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssrpdf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions.Install the
FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssrpdf
Created by Independent Third Party: Yes I
assembly in compliance with the installation method listed in
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.3
3 - "1.5" Mechanical Seam" (115)
1.5" rib height, 16" wide, 24 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.3 1.5 MECHANICAL
Approved for use outside HVHZ: Yes
seam 24ga ssrpdf
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other! Refer to evaluation report for conditions and limitations
Evaluation Reports
of use. Install the assembly in compliance with the installation
FL17022 R7 AE FL 17022.3 1.5 MECHANICAL
method listed in this report and applicable code sections of
seam 24ga ssrpdf
FBC. Refer to manufacturer's installation instructions.
Created by Independent Third Party: Yes
17022.4
4 - "1.5" Mechanical Seam" (115)
1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof
1
panel mechanically attached to 15/32" plywood or Wood Deck
with clips and fasteners.
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL17022 R7 II FL 17022.4 MECHANCIAL SEAM
( Approved for use outside HVHZ: Yes
ALUMINUM ssr.pd
i Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and limitations
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
of use. Install the assembly in compliance with the installation
FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
method listed in this report and applicable code sections of
ALUMINUM ssrpdf
FBC. Refer to manufacturer's installation instructions.
-
Created by Independent Third Party: Yes
�—
-
17022.5
5 -� 1 in. Nail Strip" (R5)
1" rib height, 16" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use {
{ Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Installation Instructions
FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssrpdf
Verified By: Locke Bowden, R E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and limitations
of use. Install the assembly in compliance with the installation
FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssrpdf
Created by Independent Third Party: Yes j
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3a 2/3
8/28/2020
Florida Building Code Online
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
j 17022.6 16 - "1 in. Nail Strip" (115) 1" rib height, 16" wide, 0.032" aluminum, standing seam roof
panel mechanically attached to attached to 15/32' plywood or
Wood Deck with fasteners,
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and limitations
of use. Install the assembly in compliance with the installation
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
Installation Instructions
FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032
ALUM ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032
ALUM ssr.pdf
Created by Independent Third Party: Yes
17022.7 7 - "1.5 in. Nail Strip" (R5) 1.5" rib height, 19" wide, 26 gauge steel, standing seam roof
I panel mechanically attached to 15/32" plywood or wood deck
i with fasteners.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and limitations
of use. Install the assembly in compliance with the installation
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
17022.8 18 - "EMAX Rib" (115)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and limitations
of use. Install the assembly in compliance with the installation
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
17022.9 19 - " PBR MAX" (R5)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and limitations
of use. Install the assembly in compliance with the installation
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
Installation Instructions
FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.pdf
Created by Independent Third Party: Yes
29 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Installation Instructions
FL17022 R7 II FL 177022.8 EMAX Rib ssr.pd
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 177022.8 EMAX Rib ssr.pd
Created by Independent Third Party: Yes
26 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Installation Instructions
FL17022 R7 II FL 17022.9 PBR RIB ssr.pdf
Verified By: Locke Bowden, RE, 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.9 PBR RIB ssr.pdf
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road,. Tallahassee FL 32399 Phone: 850-487-1824
The Skate of Florida is an AA/EEO employer, CopyLght 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
cLfecY
Credit Card
Safe
https://www.floddabuilding.org/pr/pr app_otl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 3/3
Palm City, Fl. 34990
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec.1507.4.2
Yield strength: 50 ksi min., Attached to min.15/32" plywood or Wood
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chance 2500 .9.
Slope: Shall be in compliance with FBC Sec. 1507.
See Fastener attachment specifications above
Install Details: Table A Allowable Loads
METHOD 1
METHOD 2
METHOD 3
METHOD 4
DESIGN PRESSURE*
-86 PSF
-93.5 PSF
-101 PSF
-228 PSF
-ROW SPACING
16" o.c.
16" o.c.
8" o.c.
6" o.c.
FASTENER SPACING (ALONG Panel width)
12" o.c.
12" o.c.
12" ax.
12" o.c.
FASTENER SIZE
#9
#10
#10
#10
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527
UL 580-06 & 1897-041 Test Report 035893.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY-UL 1897--04 is equivalent to test standard UL 1897-1 *Design pressure margin of safety 2r1
Locke Bowden, P.E. does not have, not will acquire a financial in4t �a +cg rj�►��cturing or distributing products
under this evaluation.
Locke Bowden, P.E. is not owned, operated, or controlled by alfy coniparN;)n-A8ifa$turer, or distributing products under this
fXT'r-
_;7/7
*"'�h� •.fit ��?I��� °°'�,},
FL17O22.1 5V Crimp (26GA Steel), 24"' Wide Roof Panel - Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed.
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
Deck:
15/32" or greater Plywood, or
Wood plank
24-
• 12'°
QP rl3id4�STRIATIONS
Panel Profile
Nominal 12" Nominal 12"
O.C. O.C.
Fasten
#9 x 1-1/2" Min. or #10 x 1-1/2" Min. per
Table "A" Hex Washer Head Screw
Spaced 12" o.c. across the Panel Width
Panel Refer to Table "A" for Spacing Along Panel
Overlap Length
Deck-15/32" or greater
Plywood, or
- Wood plank
8/28/2020
Florida Building Code Online
sustnelss• Professional
rA
BCIS Home I Log In User Registration Hot Topics Submit Surcharge Stats & Facts 'i Publications ( Contact Us i BCIS Site Map d Links Search
F1 rid
t' Product Approval � or
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL11602-R10
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer Owens Corning Roofing and Asphalt, LLC
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43645
(740)321-6345
Greg.Keeler@owenscorning.com
Authorized Signature Keeler Greg
Greg.Keeler@owenscorning.com
Technical Representative Greg Keeler
Address/Phone/Email 2790 Columbus Road
Granville, OH 43023
(740) 321-6345
greg.keeler@owenscorning.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2020
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL11602 Rt0 COI 2019 01 COI NT MINEN,p-df
Referenced Standard and Year (of Standard)
Standard
Year
ASTM D1970
2015
ASTM D226 (physicals)
2009
ASTM D4798
2011
FRSA/TRI April 2012
2012
TAS 117(B)
1995
UL1897
2012
Equivalence of Product Standards
Certified By
https://www.floNdabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2f'rrZeHYB7UCe5KMr%2f$MfWgra38u9whFr5gP6KA%3d%3d 1/2
8/28/2020
Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
10/17/2019
Date Validated
10/17/2019
Date Pending FBC Approval
10/20/2019
Date Approved
12/10/2019
Summary of Products
I i
FL # Model, Number or Name
Description
11602.1 Titanium Roof Underlayments
Limits of Use
Synthetic sheet -type roof underlayments
Installation Instructions
Approved for use in HVHZ: No
FL11602 R10 II 2019 10 FINAL ER FL11602-R10.pdf
Approved for use outside HVHZ: Yes
Verified By: Robert Nieminen PE-59166
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-45
Evaluation Reports
Other: 1.) The design pressure noted herein pertains to use of
FL11602 R10 AE 2019 10 FINAL ER FL11602-R10.pLlf
a specific underlayment system beneath foam -on tile sytsems.
Created by Independent Third Party: Yes
Refer to ER Section 5.6.3 for details. 2.) Refer to ER Sections 5
and 6 for other Limits of Use.
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. ,CSRyri ht 2007-2013 State of Florida.:: Pri y Statement :: Accessibility. Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 45S, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
rM FWW 7 ® ¢Cteck E
Credit Card
Safe
https://www.loddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2frrZeHYB7UCe5KMr%2fsMfWgra38u9whFr5gP6KA%3d%3d 2/2