HomeMy WebLinkAboutDesign pressure calcs i
ST
- HT
A
500 SW 12th Ave
Deerfield Beach.FL 33442 IG
Ph.561-922-6747
W1 N ows
Fax.561-292-3562
Property Information Building Information
Owner: AUDRY ROLLINS Wind Zone: 160 MPH.
Address: 13207 INDIAN RIVER DR Exposure Category: D
JENSEN BEACH,FL 34957 Minimum Building Dimension: 43 ft.
Mean Roof Height: 15 ft. j
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) LPressure(psf)
1 Int 36 80 7 38.8 -42.2!
2 Int 36 37 7 40.6 -44.1
..........._-
3 End 36 37 7 40.6 -54.4
4 Int 30 80 7 39.3 -42.7
5 End 71 80 7 37.0 -47.21
i
i
i
I
1
i
i
i
I
I
I
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 1 of 1
WINDOW & DOOR OPENING INFORMATION
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 40/6 of least horizontal dimension or 3 ft.
OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING SHUTTERS
SIZE REQ YIN/NA NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS MULLION REQ Y/N
1 Int Door 1"Lami FL15210.1 75 75 38.8 -42.2 37 x 81 36x80 No No
2 _Int Window 7/8"Lami 20-0526.04 55 55 40.6 -44.1 52 x 75 36x37 No --- No -
3 End Window 7/8"Lami 20-0526.04 55 55 40.6 -54.4 52 x 75 36x37 No No
4 Int Door 1"Lami FL12100.1 75 75 39.3 -42.7 35 x 96 30x80 No No
5 End Door 1"Lami FL12100.1 75 75 37.0 -47.2 74 x 96 71x80 No No