Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3
® QQF These truss designs rely on lumber values established by others.
TRUSSES
A FLORIDA CORPORATION
RE: Job 81919
Site Information:
A-1 Roof Trusses
4451 St Lucie Blvd
Fort Pierce, FL 34946
Customer Info: RENAR DEVELOPMENT CO. Project Name: MORNINGSIDE
Lot/Block: 100 Model: CAYMAN 1560
Address: 9792 PALM BREEZES DRIVE Subdivision:
City: County: St Lucie State: FL
Name Address and License # of Structural Engineer of Record, If there is one, for the building.
Name: License #:
Address:
City:
General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading
Conditions):
Design Code: FBC 2017 RES / TPI 2014 Design Program: Alpine Engineered Products
Wind Code: ASCE 7-10 Wind Speed: 160
Roof Load: 37.0 psf Floor Load: 0.0 psf
This package includes 45 individual, dated Truss Design Drawings and 16 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
i
'No.
Seq #
Truss Name
Date
No.
Seq #
Truss Name
Date
No.
Seq #
Truss Name
1
2505
A01
7/13/20
13
3361
A13
7/13/20
25
2590
HJ7
_Date
7/13/20
2
3376
A02
7/13/20
14
3466
B01
7/13/20
26
2569
HJ7A
7/13/20
3
3391
A03
7/13/20
15
3470
B02
7/13/20
27
3463
HJ713
7/13/20
4
3334
A04
7/13/20
16
2530
B03
7/13/20
28
2499
HJ7P
7/13/20
1 5
3431
A05
7/13/20
17
2572
C01
7/13/20
29
2593
J1
7/13/20
6
3421
A06
7/13/20
18
3407
CO2
7/13/20
30
2487
J1P
7/13/20
7
3414
A07 _
7/13/20
19
3401
CO3
7/13/20
31
2596
J3
7/13/20
8
3365
A08
7/13/201
20
12514
E01
7/13/201
32
13434
J3A
7/13/20
9
3398
A09
7/13/20
21
2587
E02
7/13/20
33
2490
J3P
7/13/20
10
3326
A10
7/13/20
22
2511
E03
7/13/20
34
2599
J5
7/13/20
11
3315
A11
7/13/20
23
3456
E04
7/13/20
35
2536
J5A
7/13/20
12
3322
Al2
7/13/20
24
2533
GE01
7/13/20
36
3437
1 J513
7/13/20
The truss drawing(s) referenced have been prepared bywpine Engineered Products, Inc. under my direct supervision based on the parameters provided byA-1 Roof Trusses, Ltd.
Truss Design Engineer's Name: Rama Pranav Kristam
My license renewal date for the state of Florida is February 28,2021.
NOTE: The seal on these drawings indicate acceptance of professional engineering
responsibility solely forthe truss components shown.
The suitability and use of components forany particular building is the responsibility of the building
designer, perANSUTPI-1 Sec. 2.
The Truss Design Drawing(s)(TDD[s)) referenced have been prepared based on the construction
documents (also referred to at times as'Structural Engineering Documents') provided by the Building
Designer indicating the nature and characterof the work.
The design criteria therein have been transferred to Rama Pranav Kristam PE by [Al Roof Trusses or
specific location). These TDDs (also referred to at times as'Structural Delegated'
Engineering Documents') are specialty structural component designs and may be part of the project's
deferred or phased submittals. As a Truss Design Engineer(i e., Specialty
Engineer), the seal here and on the TDD represents an acceptance of professional engineering
responsibility forthe design of the single Truss depicted on the TDD only. The Building Designer is
responsible for and shall coordinate and review the TDDs for
compatibility with their written engineering requirements. Please review all TDDs and all related notes.
Page 1 of 2
Rama Pranav Kristam, P.E.
4451 St Lucie Blvd. Suite 201
Fort Pierce, FL 34946
Rama Pranav Kristam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3
A-1 ROOF These truss designs rely on lumber values established by others.
Adlo TRUSSES
A FLORIDA CORPORATION
RE: Job ARMSCM1560B1 L
No.
Seq #
Truss Name
Date
37
2493
J5P
7/13/20
38
2539
J6
7/13/20
39
2602
J7
7/13/20
40
3368
J7C
7/13/20
41
2496
J7P
7/13120
42
2584
VM01
7/13/20
43
2581
VM02
7/13/20
44
2578
VM03
7/13/20
45
2575
VM04
7/13/20
46
STDL01
STD. DETAIL
7/13/20
47
STDL02
STD. DETAIL
7/13/20
48
STDL03
STD. DETAIL
7/13/20
49
STDL04
STD. DETAIL
7/13/20
50
STDL05
STD. DETAIL
7113/20
51
STDL06
STD. DETAIL
7/13/20
52
STDL07
STD. DETAIL
7/13/20
53
STDL08
STD. DETAIL
7/13/20
54
STDL09
STD. DETAIL
7/13/20
55
STDL10
STD. DETAIL
7/13/20
56
STDL11
STD. DETAIL
7/13120
57
STDL12
STD. DETAIL
7/13/20
58
STDL13
STD. DETAIL
7/13/20
59
STDL14
STD. DETAIL
7/13/20
60
1 STDL15STD.
DETAIL
7/13120
61
STD L16F
STD. DETAIL
7/13/20
Rama Pranav Kristam, P.E.
4 88906
Page 2 of 2 4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
JOD
ARMSCM1560Bl L
Iruss Iruss type
A01 I HIPS
c.tty Fly U1/13/1U2U
1 1 1
38'
+ 104 + 104 + 104 + 1111 + 114 + 114 +
442# 107# 107# 1074 111# 111# 442#
Loading Criteria (psf)
184#
254# 184#
184#
184#
184# 186# 1864
184# 186# 18
2544
186#
f 7,0„6 y 20"6 i 2, i
i 'f 'i'-
2, i 2,2,
-'t
11'11"4 1'11"4� 2, i 2,
i'- "f'- '1"
i 2, i
�t ' �1�
+
2, i 20°6'I' 7,0"6
`t'
F 7
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 25.00 ft
NCBCLL: 10.00
7'
Load Duration: 1.25
BCDL: 4.2 psf
24'
MWFRS Parallel Dist: 0 to h/2
=6X8=3X4
C D
=3X1
E T2
=3X6 =4X6
F G H
=4X6
I T2
-I
12
b6
Wind Duration: 1.60
Ill I
__-
T
C6(A1) B
Kffi 3X6(A1)
A
=10X10
82 g
4
L
V TU
=3X4
IIIO1. 3=P
ONa4
M
=5X6Ill 1.5X3
-5X8
=-3X6(")
1112X4
SEAT PLATE REQ.
SEAT PLATE REQ.
SEAT PLATE REQ.
21'8°
164'
�-5-g�}--- 84"6
i11
187'9 i 111
38'
+ 104 + 104 + 104 + 1111 + 114 + 114 +
442# 107# 107# 1074 111# 111# 442#
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 25.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.80 ft
Loc. from endwall: NA
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2 :172 2x4 SP M-30
Bot chord 2x4 SP #2 :132 2x4 SP M-30:
Webs 2x4 SP #3
Code / Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Varies by Ld
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Bracing
(a) Continuous lateral restraint equally spaced on member
Special Loads
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 62 plf at -1.46 to 62 pif at 7.00
TC: From 31 plf at 7.00 to 31 pif at 31.00
TC: From 62 plf at 31.00 to 62 pif at 39.46
BC: From 14 plf at 0.00 to 14 pif at 7.03
BC: From 7 plf at 7.03 to 7 plf at 30.97
BC: From 14 pif at 30.97 to 14 pif at 38.00
TC: 254 Ib Conic. Load at 7.03,30.97
TC: 184 Ib Conic. Load at 9.06,11.06,13.06,15.06
17.06,19.00
TC: 186 Ib Conc. Load at 20.94,22.94,24.94,26.94
28.94
BC: 442 Ib Conic. Load at 7.03,30.97
BC: 107 Ib Conc. Load at 9.06,11.06,13.06,15.06
17.06,19.00
BC: 111 Ib Conic. Load at 20.94,22.94,24.94,26.94
28.94
Defl/CSI Criteria
PP Deflection in loc L/defl LN
VERT(LL): 0.121 D 999 3E
%eERT(CL): 0.228 D 999 2
HORZ(LL): 0.055 M -
HORZ(TL): 0.103 M -
Creep Factor: 2.0
Max TC CSI: 0.740
Max BC CSI: 0.999
Max Web CSI: 0.997
Wgt: 204.4 lbs
VIEW Ver: 19.01.00A.0618.16
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 7.00 31.00
BC 69 0.15 8.22
BC 76 8.26 19.51
BC 75 19.51 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Plating Notes
(") 1 plate(s) require special positioning. Refer to scaled plate plot details for
special positioning requirements.
Wind
Wind loads and reactions based on MWFRS.
Right bottom chord exposed to wind.
2505
♦ Maximum Reactions (lbs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw /U / RL
40 B 1441 /- /- /- /631 /-
- P 4556 /- /- /- /2574 /-
- K 844 /- /- /- /520 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.7
P Brg Width = 8.0 Min Req = 5.4
K Brg Width = 8.0 Min Req = 1.5
Bearings B, P, & K are a rigid surface.
Bearings B, P, & K require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - B 39 -23 G - H 1294 -774
B - C 1092 -2457 H - 1 2352 -1268
C - D 1269-2841 I - J 292 -12
D - E 749 -1890 J - K 862 -1189
E - F 1292 -776 K - L 39 -23
F - G 1292 -776
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B - V 2112 -924 P-0 0 -374
V - U 85 -53 O - N 0 -374
T - S 2873 -1285 N - M 1010 -737
S - Q 1817 -731 M - K 986 -723
R -P 19 -52
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
C - V 656 -1125 Q - R 45 -29
C - T 1923 -932 Q - H 1704 -772
V - T 2616 -1105 Q - P 1297 -2386
T -U 0 -144 H -P 899 -1715
T- D 133 0 P- 1 1767 -2714
D - S 607 -1125 1- N 1092 -632
S - E 790 -192 N - J 724 -1341
E - Q 1682 -3416 M - J 598 -350
G - Q 365 -499
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St, Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SECA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
C:nnvnnht n 2016 A-1 Roof Tmee-- Renrndndion of this don rnent in env formis nmhihited withont the written nPoni-inn of A-1 Rnnf Thies-
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B - V 2112 -924 P-0 0 -374
V - U 85 -53 O - N 0 -374
T - S 2873 -1285 N - M 1010 -737
S - Q 1817 -731 M - K 986 -723
R -P 19 -52
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
C - V 656 -1125 Q - R 45 -29
C - T 1923 -932 Q - H 1704 -772
V - T 2616 -1105 Q - P 1297 -2386
T -U 0 -144 H -P 899 -1715
T- D 133 0 P- 1 1767 -2714
D - S 607 -1125 1- N 1092 -632
S - E 790 -192 N - J 724 -1341
E - Q 1682 -3416 M - J 598 -350
G - Q 365 -499
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St, Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SECA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
C:nnvnnht n 2016 A-1 Roof Tmee-- Renrndndion of this don rnent in env formis nmhihited withont the written nPoni-inn of A-1 Rnnf Thies-
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
C - V 656 -1125 Q - R 45 -29
C - T 1923 -932 Q - H 1704 -772
V - T 2616 -1105 Q - P 1297 -2386
T -U 0 -144 H -P 899 -1715
T- D 133 0 P- 1 1767 -2714
D - S 607 -1125 1- N 1092 -632
S - E 790 -192 N - J 724 -1341
E - Q 1682 -3416 M - J 598 -350
G - Q 365 -499
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St, Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SECA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
C:nnvnnht n 2016 A-1 Roof Tmee-- Renrndndion of this don rnent in env formis nmhihited withont the written nPoni-inn of A-1 Rnnf Thies-
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St, Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SECA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
C:nnvnnht n 2016 A-1 Roof Tmee-- Renrndndion of this don rnent in env formis nmhihited withont the written nPoni-inn of A-1 Rnnf Thies-
Job 1 1 russ I I russ I ype ury I My un 13/LULU
ARMSCM1560BIL A02 HIPS I 1 1 3376
�- --- 9' 20' 9' j
5X6 =3X6
D E III 1.5X3 FG H I _XJ
T 12 1111.5X4 C
6
M (a)
o
T3 -
= 6X6 t"
=_3XA(A1) B 4X6(R) S Q K_3XL(A1)
TU 1111.5�C3 P=3X8 O _3X6 1111.5X3
SEAT PLATE REQ. SEAT PLATE REQ. SEAT PLATE REQ.
21'8" 16'4"
8'4"6 *{a 11' m{- 187'9 1 5 9{
38'
Loading Criteria (psf) Wind Criteria Code / Mise Criteria Defl/CSI Criteria A Maximum Reactions (Ibs), or'=PLF
TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBG 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.087 C 999 360 Loc R+ ! R- ! Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.161 C 999 240 B 682 6 /- /417 /273 /171
BCDL: 7.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.057 Q - - P 2031 /- /- /1059 /742 /-
EXP: B Kzt: NA Plate Type(s): HORZ(TL): 0.108 Q K* 45 /-11 /- /26 /11 /-
Des Ld: 37.00 Mean Height: 25.00 ft WAVE Creep Factor: 2.0 O /-112
NCBCLL: 10.00 TCDL: 5.0 psf N /-262
Load Duration: 1.25 BCDL: 4.2 psf Max TC CSI: 0.655 Wind reactions based on MWFRS
Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 Max BC CSI: 0.710
C&C Dist a: 3.80 ft Max Web CSI: 0.995 B Brg Width = 8.0 Min Req = 1.5
P Brg Width = 8.0 Min Req = 2.4
Loc. from endwall: not in 9.00 Wgt: 207.2 lbs K Brg Width = 192 Min Req = -
GCpi: 0.18 Bearings B, P, & P are a rigid surface.
Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.16 Bearings B, P, & P require a seat plate.
Lumber Maximum Top Chord Forces Per Ply (Ibs)
Top chord 2x4 SP #2 :T3 2x4 SP 2400f-2.OE: Chords Tens.Comp. Chords Tens. Comp.
Bot chord 2x4 SP #2 A - B 39 0 G - H 829 -153
Webs 2x4 SP #3 :W1 2x4 SP M-30:
B - C 414 -782 H - 1 1154 -274
Bracing C -D 681 -926 I -J 557 -86
(a) Continuous lateral restraint equally spaced on member. D - E 272 -214 J - K 244 -354
E- F 830 -154 K- L 39 0
Plating Notes F - G 830 -154
All plates are 3X4 except as noted.
Maximum Bot Chord Forces Per Ply (lbs)
Purlins Chords Tens.Comp. Chords Tens. Comp.
In lieu of structural panels or rigid ceiling use purlins B - U 612 -193 P-0 295 -598
to laterally brace chords as follows: T - S 572 -119 O - N 206 -157
Chord Spacing(in oc) Start(ft) End(ft) S - Q 188 -43 N - M 206 -157
TC 24 9.00 29.00
BC 97 0.15 8.21 R - P 4 18 M - K 201 -167
BC 120 8.21 19.51
BC 75 19.51 37.85 Maximum Web Forces Per Ply (Ibs)
Apply purlins to any chords above or below fillers Webs Tens.Comp. Webs Tens. Comp.
at 24" OC unless shown otherwise above.
C - T 525 -580 Q - H 651 -238
Wind T -U 130 0 Q -P 602 -1194
Wind loads based on MWFRS with additional C&C member design. T - D 713 -503 H - P 294 -695
D - S 202 -460 P-1 473 -1061
Additional Notes S - E 398 -67 1-0 644 -199
Negative reaction(s) of -1824 MAX. from a non -wind load case requires uplift E - Q 506 -1228 O - J 395 -789
connection. See Maximum Reactions. G - Q 157 -251 M - J 286 -153
Q -R 12 -5
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional nlZ
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
C-Mlit 0 2016 A-1 Roof Ti, s - Ranrodusfion of This dnmm"ntin anv farm. is nrohibitnd Othnnt tha wHften ne 1.,sinn of A-1 Roof Tmsses.
,footruss 1 russ 1 ype wly t-ly uff-13rzuzu
ARMSCM1560Bl L A03 HIPS 1 1 3391
16'
%6X8(R) =5X12 01111.5X3 =8X10
D E T2 F G
T12 4 I
T 6 - =H101
-1 1.5X3 C M H =1.5X3
(a) �H0308
LO
W =3X4L K
li_
3 A(A1)B 1-13X8(F1)
3 p J
O P O N 12
=3X4=4X6 =6X10 1111.5X4
SEAT PLATE REQ. SEAT PLATE REQ.
38'
P"9i
21'5"3
Loading Criteria (pet)
Wind Criteria
Code / Misc Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
O - E
EXP: B Kzt: NA
Plate Type(s):
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE, HS
NCBCLL: 10.00
TCDL 5.0 psf
291
Load Duration: 1.25
BCDL: 4.2 psf
7027 -2537
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP 2400f-2.OE :T2 2x6 SP
2400f -2.0E:
Bot chord 2x4 SP 2400f -2.0E
Webs 2x4 SP #304 2x4 SP 2400f-2.OE:
:W5, W6 2x4 SP #2:
:W7 2x4 SP M-30:
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 11.00 27.00
BC 109 0.15 21.29
BC 83 21.29 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Defl/CSI Criteria
PP Deflection in loc L/deft L/#
VERT(LL): 0.798 M 566 36
VERT(CL): 1.508 M 300 24
HORZ(LL): 0.428 K - -
HORZ(TL): 0.808 K
Creep Factor: 2.0
Max TC CSI: 0.846
Max BC CSI: 0.995
Max Web CSI: 0.851
Wgt: 210.0 lbs
VIEW Ver: 19.01.00A.0618.16
16'6"13 VSA
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw /U / RL
B 1540 /- !- /865 /563 /199
1 1544 /- /- /860 /566 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
1 Brg Width = 8.0 Min Req = 1.5
Bearings B & I are a rigid surface.
Bearings B & I require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A- B 39 0 F- G 3711 -9403
B - C 1203 -2699 G - H 1780 -4397
C - D 1076 -2359 H - 1 2006 -4705
D- E 1205 -2459 I- J 39 0
E -F 3673 -9304
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B - Q 2348 -928 M - L 4055 -1422
Q - P 2051 -691 L - K 4036 -1423
P-0 2051 -691 K - I 4228 -1712
O -N 41 -15
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C - Q
270 -338
F - M
137
-33
D -Q
387 -45
M -N
78
0
D-0
593 -300
M - G
5652
-2104
O - E
970 -2377
K - G
248
-1
0-M
3190 -1145
K -H
291
-210
E - M
7027 -2537
..WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineer'
n
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kiistam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer Is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
C.-Hnht 0 2nia A-1 Ronf Tnicsr_c - Rnnrodnrtinn nt this dnraimnnf in anv fnnn. in nmhihit,.d,"hnnt thn wriftnn nrnnissinn of A.I Rnnf Tn-es
Job Truss Truss Type Qty I Ply 0111312020
ARMSCM1560B1L A04 HIPS I 1 1 3334
go T
M
3X
r 12,8„
12'8" ^i 12'8" _ I
=5X6 =5X8 1111.5X3 =5X10
D E F G
1111.5X3 =3X6=3X4 =7X8 1111.5X3
SEAT PLATE REQ. SEAT PLATE REQ.
38'
5„9 21'5"3
-}� 16'6"13 _li 5�
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: 11
Rep Factors Used: Yes
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 25.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: h/2 to h
B Brg Width = 8.0 Min Req = 1.8
C&C Dist a: 3.80 ft
Max TC CSI: 0.641
Loc. from endwall: not in 9.00
-438
GCpi: 0.18
Bearings B & I are a rigid surface.
Wind Duration: 1.60
Lumber
Top chord 2x4 SP M-30 :T1 2x4 SP #2:
Bot chord 2x4 SP #2:B3 2x4 SP M-30:
:64 2x4 SP 240017-2.011:
Webs 2x4 SP #3:W5, W6, W7 2x4 SP #2
Code / Misc Criteria
Defl/CSI Criteria
A Maximum Reactions (Ibs)
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TPI Std: 2014
VERT(LL): 0.572 F 791 360
Loc R+ / R- / Rh / Rw /U / RL
B 1540 !- /- /872 /416 /223
Rep Factors Used: Yes
VERT(CL): 1.080 F 419 240
FT/RT:10(0)/10(10)
HORZ(LL): 0.333 K - -
1 1544 I- 1- /867 /419 /-
Plate Type(s):
HORZ(TL): 0.629 K
Wind reactions based on MWFRS
WAVE, HS
Creep Factor: 2.0
B Brg Width = 8.0 Min Req = 1.8
893 -2340
Max TC CSI: 0.641
1 Brg Width = 8.0 Min Req = 1.5
-438
Max BC CSI: 0.995
Bearings B & I are a rigid surface.
H - K
119
Bearings B & I require a seat plate.
E - N
Max Web CSI: 0.988
Maximum Top Chord Forces Per Ply (Ibs)
Wgt:215.6lbs
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver: 19.01.00A.0618.16
A - B 39 0 F - G 2401 -6060
B - C 1134 -2704 G - H 1676 -4145
C - D 1033 -2219 H - 1 1871 -4674
D- E 1067 -2109 I- J 39 0
E -F 2389 -6027
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 12.67 25.33
BC 94 0.15 21.29
BC 91 21.29 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B - S
2341 -861
N - M
3795 -1278
S - R
2339 -863
M - L
4223 -1596
R - Q
2339 -863
L - K
4209 -1600
Q - P
1906 -614
K - I
4188 -1583
P -O
23 -8
217
-41
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
S -C
209 0
F -N
146
-154
C- Q
285 -497
N-0
59
0
D - Q
363 -101
N - G
2747
-967
D -P
359 -179
M -G
217
-41
P - E
893 -2340
M - H
320
-438
P - N
3001 -1006
H - K
119
-52
E - N
4375 -1479
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedri
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI -1.
f:nnvdnht 0 201(1 A -i Rnnf Tri ...s - Ronrodnntion of this doo-ont. in anv food is nmhihilod tviihnnt tha. wntton normissinn of A-1 Rnnf T.i se.¢
uOD I russ I russ I ype Uty I illy Un1 s/Zuzu
ARMSCM1560BlL A05 HIPS 1 1
14,8„ 8'8" i 14,8"
3431
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
=5X6 1111.5X4
SEAT PLATE REQ.
1r5"9
F- -+ 11'10"12
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2 :T3 2x4 SP 2400f-2.011:
:T4, T5 2x4 SP M-30:
Bot chord 2x4 SP #2:133 2x4 SP M-30:
:B4 2x4 SP 2400f-2.OE:
Webs 2x4 SP #3:W3 2x4 SP #2:
Code / Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
Plating Notes
(1) - plates so marked were sized using 0% Fabrication Tolerance, 10 degrees
Rotational Tolerance, and/or zero Positioning Tolerance.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 14.67 23.33
BC 95 0.15 11.72
BC 89 11.72 19.00
BC 93 19.00 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
SEAT PLATE REQ.
38'
7'1"4�}- 19' 11591
Defl/CSI Criteria
♦ Maximum Reactions (lbs)
PP Deflection in loc L/deft L/# Gravity Non -Gravity
VERT(LL): 0.513 O
881 360 Loc R+ / R- / Rh / Rw /U / RL
VERT(CL): 0.971 O
466 240 B 1542 /- / /879 /412 /252
HORZ(LL): 0.346 L
- - J 1545 /- /- /873 /415 1-
HORZ(TL): 0.654 L
Wind reactions based on MWFRS
Creep Factor: 2.0
B Brg Width = 8.0 Min Req = 1.8
Max TC CSI: 0.976
J Brg Width = 8.0 Min Req = 1.5
Max BC CSI: 1.000
Bearings B & J are a rigid surface.
Max Web CSI: 0.713
Bearings B & J require a seat plate.
-702
Maximum Top Chord Forces Per Ply (Ibs)
Wgt: 193.2 lbs
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver: 19.01.00A.0618.16
A - B 39 0 F - G 1793 -4765
P - F
B - C 1100-2725 G - H 1539 -3866
C - D 1751 -4560 H -1 1513 -3913
D - E 1763 -4475 I - J 1809 -4690
E- F 1868 -4517 J- K 39 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B - R 2363 - 833 N - M 4228 -1519
R - Q 26 -11 M - L 4225 -1532
P-0 3582 -1073 L - J 4204 -1518
O - N 3536 -1105
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
C-R
521 -1241
F-0
1516
-412
C - P
1664 -468
O - G
1592
-420
R - P
2656 -933
N - G
366
-97
E - P
195 -193
N - 1
407
-702
P -Q
78 0
1-L
185
0
P - F
952 -452
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
r:nnvdnht (�) 2016 A-1 in anv form. is nrnhihitod without tho written nr+rmie<inn of A-1 Rnnf Tncv
Job I russ I russ I ype
ARMSCM1560BIL A06 HIPS
16'8"
QLY I rly u//Io/Lulu
1 1
- 4'8" 168" -
-5X6 1111.5X3 =5X6
F G H
3421
SEAT PLATE REQ.
P"1 1110"12
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
HORZ(TL): 0.584 M
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 25.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: h/2 to h
Max Web CSI: 0.772
C&C Dist a: 3.80 ft
M- J
Loc. from endwall: not in 9.00
Wgt:200.2lbs
GCpi: 0.18
VIEW Ver: 19.01.00A.0618.16 A- B 39 0 G - H 1381 -3592
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2 :T4 2x4 SP 240017-2.0E:
:T5 2x4 SP M-30:
Bot chord 2x4 SP M-30 :B1 2x4 SP #2:
:B4 2x4 SP 2400f-2.OE:
Webs 2x4 SP #3:W3 2x4 SP #2:
Code / Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 16.67 21.33
BC 95 0.15 11.72
BC 90 11.72 19.00
BC 104 19.00 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
38'
7-1 "4 . i- 19'
;F1)
SEAT PLATE REQ.
'5"9I
Defl/CSI Criteria
A Maximum Reactions (Ibs)
PP Deflection in loc L/defl
L/# Gravity Non -Gravity
VERT(LL): 0.459 O
986 360 Loc R+ / R- / Rh / Rw /U / RL
VERT(CL): 0.867 O
521 240 B 1542 1- 1- /880 /409 1280
HORZ(LL): 0.309 M
- - K 1545 P /- /874 /413 /-
HORZ(TL): 0.584 M
Wind reactions based on MWFRS
Creep Factor: 2.0
B Brg Width = 8.0 Min Req = 1.8
Max TC CSI: 0.843
K Brg Width = 8.0 Min Req = 1.5
Max BC CSI: 0.996
Bearings B & K are a rigid surface.
1269
Bearings B & K require a seat plate.
Max Web CSI: 0.772
78 0
M- J
Maximum Top Chord Forces Per Pty (Ibs)
Wgt:200.2lbs
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver: 19.01.00A.0618.16 A- B 39 0 G - H 1381 -3592
B - C 1065 -2721 H -1 1925 -4620
C - D 1685 -4510 I - J 1889 -4643
D - E 1696 -4425 J - K 1753 -4714
E- F 1847 -4523 K- L 39 0
F - G 1381 -3591
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - R 2359 -801 O - N 3225 -905
R - Q 29 -10 N - M 3206 -915
P-0 3219 -844 M - K 4228 -1461
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
C-R
495 -1217
F-0
901
-215
C - P
1630 -447
G-0
95
-54
R - P
2639 -894
0-H
960
-181
E - P
277 -328
H - M
1269
-639
P- Q
78 0
M- J
379
-456
P - F
1262 -645
*`WARNING** Please thoroughly review the "A -I ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seat on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Krislam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
C:nnvdnhf n 2016 A-1 Rnnf T -s-- Reoroduclinn of this d-ument In anv form. is nrnhIMPA wiihnut the wriHnn -mi«inn of A-1 Roof T--
-
Job Truss Truss Type Qty Ply 07/13/2020 3414
ARMSCM1560BlL A07 HIPS 1 1
18'81.i
8„
18'8"
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
SEAT PLATE REQ.
1'5"9
�}� 11'10"12
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2:T3, T4 2x4 SP M-30:
Bot chord 2x4 SP M-30:131 2x4 SP #2:
:B4 2x4 SP 2400f -2.0E:
Webs 2x4 SP #3:W3 2x4 SP #2:
38'
7'1"4
Code / Misc Criteria
Defl/CSI Criteria
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
TPI Std: 2014
VERT(LL): 0.467 N 969 36
Rep Factors Used: Yes
VERT(CL): 0.883 N 512 24
FT/RT:10(0)/10(10)
HORZ(LL): 0.325 L - -
Piate Type(s):
HORZ(TL): 0.615 L
WAVE, HS
Creep Factor: 2.0
Tens. Comp.
Max TC CSI: 0.923
1057 -3228
Max BC CSI: 0.985
1466 -4269
Max Web CSI: 0.909
1449 -4346
Wgt: 191.8 Ibs
1650 -4760
VIEW Ver: 19.01.00A.0618.16
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
(**) 1 plate(s) require special positioning. Refer to scaled plate plot details for
special positioning requirements.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 96 0.15 11.75
BC 89 11.79 19.00
BC 101 19.00 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
SEAT PLATE REQ.
19' i
1 5i�
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- ! Rh / Rw /U / RL
B 1542 /- /- /869
/400 /310
J 1545 /- /- /864
/403 /-
Wind reactions based on MWFRS
1649 -380
B Brg Width = 8.0 Min Req = 1.8
J Brg Width = 8.0 Min Req = 1.5
Bearings B & J are a rigid surface.
Q-0
Bearings B & J require a seat plate.
F - N
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords
Tens. Comp.
A- B 39 0 F- G
1057 -3228
B - C 980 -2716 G - H
1466 -4269
C - D 1516 -4517 H - 1
1449 -4346
D - E 1529 -4432 I - J
1650 -4760
E- F 1072 -3241 J- K
39 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B - Q 2353 -717 N - M 3723 -1036
Q- P 29 -9 M- L 3704 -1044
O - N 4105 -1120 L - J 4280 -1383
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
C - Q
448 -1201
E - N
624 -1203
C-0
1649 -380
N - G
496
-814
Q-0
2626 -798
F - N
2385
-671
O -P
80 0
G -L
517
-95
O - E
432 -90
L - I
316
-341
-WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
Convnnht 0 2016 AA Rnnf Tms, t - Runrodnntinn of this doo-nt. in anv fnon is nmhihitod with -t tho vmnPn nP.r Ni ion of A-1 Rnnf Tnresec.
Job Truss Truss Type QtyPly 07/13/2020
ARMSCM1560BlL A08 COMN 2 I 1 3365
6.=5X6
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
(1) - plates so marked were sized using 0% Fabrication Tolerance, 10 degrees
Rotational Tolerance, and/or zero Positioning Tolerance.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 95 0.15 11.75
BC 89 11.79 19.00
BC 100 19.00 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp, Chords Tens. Comp.
B - Q 2353 -734 N - M 3724 -1069
Q- P 29 -9 M- L 3695 -1071
O - N 4105-1155 L - J 4283 -1411
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp. Webs Tens. Comp
C -Q
SEAT PLATE REQ.
1'5"9
�- --�^-- 11'10"12
7'1"4
38'
SEAT PLATE REQ.
11'5"9
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
A Maximum Reactions (Ibs)
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl
L/# Gravity Non -Gravity
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.469 N
963 360 Loc R+ / R- / Rh / Rw /U / RL
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.888 N
509 240 B 1542 /- !- /876 1407 /314
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.328 L
- - J 1545 /- /- 1870 /410 /-
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.620 L
Wind reactions based on MWFRS
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE, HS
Creep Factor: 2.0
B Brg Width = 8.0 Min Req = 1.8
NCBCLL: 10.00
TCDL: 5.0 sf
p
Max TC CSI: 0.923
J Brg Width = 8.0 Min Req = 1.5
Load Duration: 1.25
"
BCDL: 4.2 psf
Max BC CSI: 0.993
Bearings B & J are a rigid surface.
Spacing: 24.0
MWFRS Parallel Dist: h/2 to h
Bearings B & J require a seat plate.
C&C Dist a: 3.80 ft
Max Web CSI: 0.909
Maximum Top Chord Forces Per Ply (lbs)
Loc. from endwall: not in 9.00
Wgt: 193.2 lbs
Chords Tens.Comp, Chords Tens. Comp.
GCpi: 0.18
Wind Duration: 1.60
VIEW Ver: 19.01,00A.0618.16 A -B 39 0 F -G 1093 -3227
Lumber
B - C 998 -2717 G - H 1497 -4276
C - D 1554 -4518 H-1 1479 -4349
Top chord 2x4 SP #2 :T3,
T4 2x4 SP M-30:
D - E 1567 -4436 l - J 1680 -4764
Bot chord 2x4 SP M-30
:B1 2x4 SP #2:
E - F 1110 -3240 J - K 39 0
:B4 2x4 SP 2400f -2.0E:
Webs 2x4 SP #3:W3 2x4
SP #2:
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
(1) - plates so marked were sized using 0% Fabrication Tolerance, 10 degrees
Rotational Tolerance, and/or zero Positioning Tolerance.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 95 0.15 11.75
BC 89 11.79 19.00
BC 100 19.00 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp, Chords Tens. Comp.
B - Q 2353 -734 N - M 3724 -1069
Q- P 29 -9 M- L 3695 -1071
O - N 4105-1155 L - J 4283 -1411
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp. Webs Tens. Comp
C -Q
458 -1201
E -N
619 -1205
0-0
1649 -393
F - N
2386
-684
Q-0
2627 -817
N - G
489
-817
O -P
80 0
G -L
519
-94
O - E
432 -90
L-1
314
-341
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise slated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -f. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI -1.
Cn o.ht 02016 A-1 Rnnf TnI.,Aa-s– Ro—rindion of this Anrmmont. in anv formin nnof ihind. iftnt thn. wHfle normiRslon of A-1 Roof To—,
Job Iruss Iruss type
t
ARMSCM1560B1L A09 COMN
M
O
�T
l_73 s3:
19'
c.tty my U111312U2U
4 (1
19'
F=5X6
3398
SEAT PLATE REQ. SEAT PLATE REQ.
I Ai
38'
P"
9
19'
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/deft L/#
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.512 N 883 36
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.970 N 466 24,
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.365 L - -
C - D 1471 -4346 H - 1
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.692 L
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE, HS
NCBCLL: 10.00
TCDL: 5.0 psf
Creep Factor: 2.0
Load Duration: 1.25
BCDL: 4.2 psf
Max TC CSI: 0.673
Spacing: 24.0 "
MWFRS Parallel Dist: h to 2h
Max BC CSI: 0.743
C&C Dist a: 3.80 ft
Max Web CSI: 0.928
Loc. from endwall: not in 9.00
Wgt: 175.0 Ibs
GCpi: 0.18
VIEW Ver: 19.01.00A.0618.16
Wind Duration: 1.60
Lumber
Top chord 2x4 SP M-30
Bot chord 2x4 SP 2400f-2.OE :B2 2x4 SP M-30:
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.15 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw /U / RL
B 1546 /- /- /870
/199 /314
J 1546 /- /- /870
/199 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
J Brg Width = 8.0 Min Req = 1.5
Bearings B & J are a rigid surface.
Bearings B & J require a seat plate.
Maximum Top Chord Forces Per
Ply (Ibs)
Chords Tens.Comp. Chords
Tens. Comp.
A- B 39 0 F- G
1089 -3229
B - C 1677 -4758 G - H
1494 -4269
C - D 1471 -4346 H - 1
1476 -4346
D - E 1488 -4269 I - J
1675 -4758
E- F 1114 -3229 J- K
39 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B - P 4277 -1372 N - M 3732 -1064
P-0 3713 -1026 M - L 3713 -1072
O - N 3732 -1018 L - J 4277 -1406
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
C - P 309 -337 N - G 497 -828
P - E 509 -85 G - L 509 -88
E - N 498 -828 L - I 311 -337
F - N 2437 -710
—WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the Too, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field ti 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
(;nnvdnht 0 201E A-1 Rnnf Tm.¢.atw – Renrndnntinn of this dnoumantin anv fnnnis nrnhihitad Whnnt tha wditan -miacinn of A-1 Rnnf T,
Job Truss Truss Type Qty I Ply 07/13/2020
ARMSCM1560B1L A10 COMN 1 3 1
19' 19'
F=fixR
3326
SEAT PLATE REQ. SEAT PLATE REQ.
38'
P"21, 19'
+ 8'1"6
10'10"10 - — 5�
Loading Criteria (psf) Wind Criteria Code / Misc Criteria
Defi/CSI Criteria
A Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES
PP Deflection in loc L/deft L/#
Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph TPI Std: 2014
VERT(LL): 0.467 O 969 360
Loc R+ / R- / Rh / Rw /U / RL
BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes
VERT(CL): 0.883 O 512 240
B 1546 /- /- /870 /199 /314
BCDL: 7.00Risk Category: II FT/RT:10(0)/10(10)
HORZ(LL): 0.325 L - -
J 1542 /- /- /875 /195 /-
EXP: B Kzt: NA Plate Type(s):
HORZ(TL): 0.614 L
Wind reactions based on MWFRS
Des Ld: 37.00 Mean Height: 25.00 it WAVE, HS
Creep Factor: 2.0
B Brg Width = 8.0 Min Req = 1.5
NCBCLL: 10.00 TCDL: 5.0 psf
Max TC GSI: 0.686
J Brg Width = 8.0 Min Req = 1.8
Load Duration: 1.25 BCDL: 4.2 psf
Max BC CSI: 0.749
Bearings B & J are a rigid surface.
Spacing: 24.0 " MWFRS Parallel Dist: h to 2h
Bearings B & J require a seat plate.
C&C Dist a: 3.80 ft
Max Web CSI: 0.898
Maximum Top Chord Forces Per Ply (lbs)
Loc. from endwall: not in 9.00
Wgt: 193.2 lbs
Chords Tens.Comp. Chords Tens. Comp.
GCpi: 0.18
Wind Duration: 1.60
VIEWVer:19.01.00A.0618.16
A -B 39 0 F -G 1082 -3269
Lumber
B - C 1684 -4765 G - H 1659 -4613
C - D 1473 -4347 H - 1 1651 -4708
Top chord 2x4 SP M-30 :T3 2x4 SP #2:
D - E 1491 -4274 I - J 996 -2723
Bot chord 2x4 SP M-30 :B1 2x4 SP 2400f -2.0E:
E - F 1125 -3238 J - K 39 0
:B4 2x4 SP #2:
Webs 2x4 SP #3:W7 2x4 SP #2:
Maximum Bot Chord Forces Per Ply (Ibs)
Bracing
Chords Tens.Comp. Chords Tens. Comp.
(a) Continuous lateral restraint equally spaced on member.
B - Q 4285 -1379 0-M 4303 -1306
Plating Notes
Q - P 3693 -1020 N - L 33 -12
P-0 3722 -1018 L - J 2361 -758
(1) - plates so marked were sized using 0% Fabrication Tolerance, 10 degrees
Rotational Tolerance, and/or zero Positioning Tolerance.
Maximum Web Forces Per Ply (lbs)
Purlins
Webs Tens.Comp. Webs Tens. Comp.
In lieu of structural panels or rigid ceiling use purlins
C - Q 315 -345 G - M 421 -65
to laterally brace chords as follows:
Q - E 513 -95 M - N 74 0
Chord Spacing(in oc) Start(ft) End(ft)
E-0 480 -800 M - L 2640 844
BC 120 0.15 19.00
BC 101 19.00 27.22
F-0 2357 -651 M -1 1829 -516
BC 120 27.26 37.85
O - G 703 -1368 L - I 468 -1239
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI -1.
C'o Haht 02n1fi A-1 Rnof Tnissr_¢ – Renrndnrtinn of this dno .nt. in anv fnrm. is nmhihit,,d Qhnnt IM u,ft- n—iasinn of A-1 Roof Tnicsos
Job I russ I russ I ype Laty rty U//1j/2U2u
I ARMSCM1560B1L ( A11 HIPS ( 1 1 3315
j- 17,8"1 i
2714
5X6
c r_
17'8"1
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
=3X10 1111.5X4 1111.5X4 =5X6 =3X6=3X4
SEAT PLATE REQ. SEAT PLATE REQ.
38'
F-5""91 11'11"2 0 2 772 i 18'10"10
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2 :B2 2x4 SP M-30:
Webs 2x4 SP #3:W3 2x4 SP #2:
Code / Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
(1) - plates so marked were sized using 0% Fabrication Tolerance, 10 degrees
Rotational Tolerance, and/or zero Positioning Tolerance.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 17.67 20.33
BC 120 0.15 11.78
BC 104 11.82 20.18
BC 75 20.18 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Deft/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.381 P 999 361
VERT(CL): 0.719 P 629 24(
HORZ(LL): 0.251 M - -
HORZ(TL): 0.474 M -
Creep Factor: 2.0
Max TC CSI: 0.618
Max BC CSI: 0.768
Max Web CSI: 0.978
Wgt: 238.0 lbs
VIEW Ver: 19.01.00A.0618.16
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 1540 /- !- 1877
/199 /295
K 1540 /- /- /876
/199 /-
Wind reactions based on MWFRS
W -V
B Brg Width = 8.0 Min Req = 1.8
K Brg Width = 8.0 Min Req = 1.8
Bearings B & K are a rigid surface.
-3
Bearings B & K require a seat plate.
4070 -1229
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords
Tens. Comp.
A- B 39 0 G- H
1408 -3982
B - C 1039 -2715 H - I
1027 -2394
C - D 1629 -4497 1 - J
1007 -2442
D - E 1646 -4438 J - K
1064 -2692
E- F 1250 -3364 K- L
39 0
F - G 1341 -3514
550 -1082
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B - W
2352 -776
R - P
3076
-737
W -V
29 -9
Q -O
7
-3
U - T
4070 -1229
O - N
1976
-624
T - R
3057 -728
N - M
1976
-624
S- Q
1 -2
M- K
2336
-825
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
C - W
480 -1203
S - R
65
-36
C - U
1627 -427
P - Q
109
-31
W - U
2628 -866
P - G
1511
-465
U- V
80 0
P-0
2568
-808
U - E
452-111
P - H
1581
-258
E - T
550 -1082
0-H
550
-1624
F - T
358 -169
H - M
352
-105
F - P
1035 -309
M - J
234
-323
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Thus Design Engineering (i.e. Specialty Engineer), the seat on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -i.
C:n-nnht 0�) 2016 A-1 Roof Tn..ccnc - Ronmdnolion of this dom-nni in anv fnrm in nrnhihitnd wilhnuf the wniton nnnnin.m of AA Roof T..-..
Job Truss Truss Type Qty Ply 07/13/2020
ARMSCM1560BlL (Al2 HIPS I I 1
j 15'8"1
6'7"14
1111.5X3 =6X10
3322
=5X6 1111.5X4 1111.5X3 1117X8(R) =3X6
SEAT PLATE REQ.
V'q1- 11'11"2 .i - 77°4
Loading Criteria (psf)
Wind Criteria
TCLL 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
Bearings B & K require a seat plate.
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 25.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: IT to 2h
900 -1998
C&C Dist a: 3.80 ft
1074 -2657
Loc. from endwall: not in 9.00
39 0
GCpi: 0.18
J- M
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2:B2 2x4 SP M-30:
Webs 2x4 SP #3:W3, W8, W9 2x4 SP #2:
Code / Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 15.67 22.33
BC 120 0.15 11.75
BC 93 11,75 19.26
BC 120 19.26 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
P1.1
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.448 G 999 36
VERT(CL): 0.845 G 535 24
HORZ(LL): 0.298 M -
HORZ(TL): 0.562 M -
Creep Factor: 2.0
Max TC CSI: 0.896
Max BC CSI: 0.988
Max Web CSI: 0.897
Wgt: 222.6 Ibs
VIEW Ver: 19.01.00A.0618.16
SEAT PLATE REQ.
18'101,10 -11 5�
A Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 1540 /- /- /878
1216 /266
K 1539 /- /- /877
/216 /-
Wind reactions based on MWFRS
1674 -470
B Brg Width = 8.0 Min Req = 1.8
K Brg Width = 8.0 Min Req = 1.8
Bearings B & K are a rigid surface.
2649 -915
Bearings B & K require a seat plate.
3180 -933
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords
Tens. Comp.
A- B 39 0 G- H
1721 -4493
B - C 1084 -2718 H -1
930 -1962
C - D 1724 -4559 I - J
900 -1998
D - E 1745 -4525 J - K
1074 -2657
E- F 1882 -4559 K- L
39 0
F- G 1725 -4516
J- M
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B - T 2356 -818 O - N 2284 -819
T -S 26 -11 N -M 2284 -819
R - P 3497 -994 M - K 2286 -818
Q -O 12 -5
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C -T
511 -1237
G -P
83 -104
C-R
1674 -470
P- Q
6 0
T - R
2649 -915
P-0
3180 -933
E - R
258 -291
P - H
3974 -1131
R- S
78 0
0-H
679 -2313
R - F
1025 -530
O - J
368 -690
F- P
1474 -443
J- M
278 0
"WARNING`" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Prenav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
Convnnhfn 2f)1a A.1 Rod Tn,s -- Renroduolinn of this d--ent io anw fmm, ie nmhibitn f without the written neon. -ion of A-1 Roof Tniceee.
Job Truss
ARMSCM1560BlL A13
r r
T russ Type
SPEC
GMy
1
Ply 0//13/2020
1
3361
15'6"
TCDL: 10.00
1,10. 1 611"15
TPI Std: 2014
13'8"l
Enclosure: Closed
Rep Factors Used: Yes
BCDL: 7.00
F=7X
FT/RT:10(0)/10(10)
/874
EXP: B Kzt: NA
Plate Type(s):
Des Lid: 37.00
G 8X H(S ) T4
8X14
I
NCBCLL: 10.00
TCDL: 5.0 psf
1111.5X3 E
W
Creep Factor: 2.0
Spacing: 24.0 "
MWFRS Parallel Dist: h to 2h
12
6
= 1.8
C&C Dist a: 3.80 ft
3X6
Loc. from endwall: not in 9.00
D
!T
Max BC CSI: 0.937
=H1014
Bearings B & L are a rigid
J
K�3X4
ch
4X4C
-
---
S Q
B2 %8X10(R)
(a)
Top chord 2x4 SP #2 :T4
iv m
i� oo
W T 7X8
W9
Webs 2x4 SP #3:W3,
W6, W9 2x4 SP #2:
Chords Tens.Comp.
d r
-
Tens. Comp.
a 3
Bracing
G - H
tt
ZN =3XA6(Al)8
l
restraint equally spaced on member.
12
H - 1
2554 -6623
3X6(Al)
L
to laterally brace chords as follows:
1008 -2112
Chord Spacing(in
oc) Start(ft) End(ft)
J - K
TC 24
17.33 24.33
E - F 1956 -4593
BC 120
0.15 11.75
3X10
1111.5X4
1111 5X3
_=5X10
=33X6 1111.5X3
SEAT PLATE REQ.
Chords
Tens. Comp.
B - V 2357 -837
SEAT PLATE REQ.
27 -9
38'
P-0
2320 -876
11'11"2
O - N
7'2"4 i
18'10"10
VFA
i
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
BCDL: 7.00
Risk Category: 11
FT/RT:10(0)/10(10)
/874
EXP: B Kzt: NA
Plate Type(s):
Des Lid: 37.00
Mean Height: 25.00 ft
WAVE, HS
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 4.2 psf
Creep Factor: 2.0
Spacing: 24.0 "
MWFRS Parallel Dist: h to 2h
Min Req
= 1.8
C&C Dist a: 3.80 ft
L Brg Width = 8.0
Loc. from endwall: not in 9.00
= 1.8
Max BC CSI: 0.937
GCpi: 0.18
Bearings B & L are a rigid
surface.
Wind Duration: 1.60
Max Web CSI: 0.943
Lumber
Bearings B & L require a
seat plate.
Top chord 2x4 SP #2 :T4
2x4 SP M-30:
Bot chord 2x4 SP #2 :132 2x6 SP 2400f-2.OE:
Per Ply (Ibs)
Webs 2x4 SP #3:W3,
W6, W9 2x4 SP #2:
Chords Tens.Comp.
:W11 2x4 SP M-30:
Tens. Comp.
VIEW Ver: 19.01.00A.0618.16
Bracing
G - H
2028 -5174
(a) Continuous lateral
restraint equally spaced on member.
Purlins
H - 1
2554 -6623
In lieu of structural panels or rigid ceiling use purlins
C - D 1804 -4614
to laterally brace chords as follows:
1008 -2112
Chord Spacing(in
oc) Start(ft) End(ft)
J - K
TC 24
17.33 24.33
E - F 1956 -4593
BC 120
0.15 11.75
BC 91
11.75 19.16
39 0
BC 120
19.26 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
PP Deflection in loc L/deft L/#
Gravity
Non -Gravity
VERT(LL): 0.621 Q
729 360
Loc R+ / R- / Rh
/ Rw
/U / RL
VERT(CL): 1.170 Q
386 240
B 1540 /- /-
/874
/211 /264
HORZ(LL): 0.366 N
- -
L 1539 /- /-
/872
/222 /-
HORZ(TL): 0.690 N
Wind reactions based on MWFRS
Creep Factor: 2.0
B Brg Width = 8.0
Min Req
= 1.8
Max TC CSI: 0.737
L Brg Width = 8.0
Min Req
= 1.8
Max BC CSI: 0.937
Bearings B & L are a rigid
surface.
Max Web CSI: 0.943
Bearings B & L require a
seat plate.
Maximum Top Chord Forces
Per Ply (Ibs)
Wgt:229.6lbs
Chords Tens.Comp.
Chords
Tens. Comp.
VIEW Ver: 19.01.00A.0618.16
A - B 39 0
G - H
2028 -5174
B - C 1123 -2718
H - 1
2554 -6623
C - D 1804 -4614
I - J
1008 -2112
D - E 1825 -4581
J - K
982 -2145
E - F 1956 -4593
K - L
1124 -2688
F- G 2369 -5977
L- M
39 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords
Tens. Comp.
B - V 2357 -837
R - P
27 -9
V - U 34 -12
P-0
2320 -876
T - S 3427 -992
O - N
2320 -876
S - Q 6972 -2298
N - L
2322 -874
Maximum Web Forces
Per Ply (Ibs)
Webs Tens.Comp.
Webs
Tens. Comp.
C - V 528 -1251
S - H
992 -2725
C - T 1721 -508
H - Q
2122 -690
V- T 2649 -939
Q- R
63 0
E - T 247 -266
Q - P
2476 -814
T- U 78 0
Q - 1
5170 -1695
T - F 1160 -593
P-1
468 -1360
F - S 4035 -1535
P - K
311 -564
G- S 1077 -2636
K- N
231 0
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verily design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kiistam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
Cnnvdnht n 2016 A-1 Rnnr Tma,et - Renrnd-Ainn of thi, do,.-nnl in nnv form ie n Inhited wfhnut the wrihnn nermittinn of A-1 Rnnf innate,
ARMSCM1560Bl L
B01 COMN'YP"
1•Y 1 y I u„ v,cvcv
2544 8¢ 1864
7'0'•6 - 2'0"6 70, 8'i"2„a x 2�6,�6 7�0��6
I� 7- 5'4' •�- 7'i --i
SEAT PLATE REQ.
1' -
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
BC: From 14 pif at 0.00 to
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 25.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
TC: 186 Ib Cone. Load at 9.06,10.27
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2:T2 2x4 SP M-30
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Special Loads
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 62 plf at -1.46 to
62 plf at
7.00
TC: From 31 plf at 7.00 to
31 plf at
12.33
TC: From 62 plf at 12.33 to
62 pif at
19.33
BC: From 14 pif at 0.00 to
14 plf at
7.03
BC: From 7 pif at 7.03 to
7 pif at
12.30
BC: From 14 plf at 12.30 to
14 plf at
19.33
TC: 254 Ib Cone. Load at 7.03
TC: 186 Ib Cone. Load at 9.06,10.27
TC: 255 Ib Cone. Load at 12.30
BC: 442 Ib Cone. Load at 7.03
BC: 111 Ib Cone. Load at 9.06,10.27
BC: 448 Ib Cone. Load at 12.30
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 7.00 12.33
BC 59 0.15 19.19
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
4424 111# 1114 448#
Code / Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Varies by Ld
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.102 H 999 36
'i RT(CL): 0.190 H 999 24
HORZ(LL): 0.044 F - -
HORZ(TL): 0.082 F
Creep Factor: 2.0
Max TC CSI: 0.665
Max BC CSI: 0.992
Max Web CSI: 0.233
Wgt: 81.2 Ibs
VIEW Ver: 19.01.00A.0618.16
SEAT PLATE REQ.
i
1
3466
A Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw /U / RL
B 1723 ! /- 1- /834 /-
E 1630 /- /- /- /772 /-
Wind reactions based on MWFRS
B Erg Width = 8.0 Min Req = 2.0
E Brg Width = 8.0 Min Req = 1.9
Bearings B & E are a rigid surface.
Bearings B & E require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - B 39 -26 C - D 1303 -2743
B - C 1496 -3090 D - E 1507 -3099
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - H 2681 -1284 G - F 2705 -1287
H - G 2705 -1287 F - E 2693 -1296
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C - H 594 -74 F - D 612 -80
C -F 46 -19
*"WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the [Be, local building code and TPI -1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
C nvdnht 02016 AA Rnnf Tn .s ., - Rrnmdunlion of thio dor--tin anv fnrrn. is nrnhihit"d without tho.nan- nnrmh-mr, nt A-1 Rnnf Tm ert
Job Truss Truss Type QtyPly 07/13/2020
(ARMSCM1560BlL I B02 I HIPS 1 11 I 3470
Y
1'4"
%5X6(R) T2 X66(R)
87'12 -I
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
SEAT PLATE REQ.
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP M-30 :T2 2x4 SP #2:
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 9.00 10.33
BC 83 0.15 18.89
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Code / Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Wind
Wind loads based on MWFRS with additional C&C member design.
=DAU III I.DAJ
=3X4(81)
I t
SEAT PLATE REO.
18'11"12
Defl/CSI Criteria
PP Deflection in loc L/deft L/#
VERT(LL): 0.028 G 999 36
VERT(CL): 0.072 G 999 24,
HORZ(LL): 0.016 G - -
HORZ(TL): 0.040 G
Creep Factor: 2.0
Max TC CSI: 0.723
Max BC CSI: 0.968
Max Web CSI: 0.090
Wgt: 75.6 Ibs
VIEW Ver: 19.01.00A.0618.16
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- ! Rh / Rw /U / RL
B 818 /- /- /470 /358 /142
E 719 /- /- /379 /303 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
E Brg Width = 3.8 Min Req = 1.5
Bearings B & E are a rigid surface.
Bearings B & E require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A- B 39 0 C- D 494 -824
B - C 436 -1030 D - E 455 -1033
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - G 821 -270 F - E 821 -269
G - F 824 -269
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C - G 237 -90 F - D 237 -82
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' forrn.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
(:onvdaht a) M1 A-1 Ronf TmeFe_C – Renrndnrlinn of this rinmeeAnt in env I— is nrnhihited withnnt the whiten nanniseinn of A -i Rnnf T—e<.
Jot)uss truss lypn Wry My V//I014UGV
ARMSCM1560BIL B03 trI SPEC 2 1 ( 2530
g,8„
12
6
N 1111.5X3 C
fn
3X4(A1) B
y°a A
I H
=3X4 =3X4
SEAT PLATE REQ.
Lumber
Top chord 2x4 SP 42
Bot chord 2x4 SP 42
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 110 0.15 18.89
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
4199H
D=4X4
E 1111.5X3
G
=3X4
18'11"12
I3X4(B1)
SEAT PLATE REQ.
Defi/CSI Criteria
A Maximum Reactions (Ibs)
PP Deflection in loc L/deft L/#
Gravity Non -Gravity
VERT(LL): 0.047 G 999 360
Loc R+ / R- / Rh / Rw /U / RL
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
EXP: B Kzt: NA
Plate Type(s):
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE
NCBCLL: 10.00
TCDL 5.0 psf
B -C 515 -1301 E -F 499 -1251
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
Chords Tens.Comp. Chords Tens. Comp.
C&C Dist a: 3.00 ft
I - H 693 -209 G - F 1062 -392
Loc. from endwall: not in 9.00
Maximum Web Forces Per Ply (Ibs)
GCpi: 0.18
C-1 245 -253 D - G 483 -217
Wind Duration: 1.60
I- D 547 -238 G - E 240 -235
Lumber
Top chord 2x4 SP 42
Bot chord 2x4 SP 42
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 110 0.15 18.89
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
4199H
D=4X4
E 1111.5X3
G
=3X4
18'11"12
I3X4(B1)
SEAT PLATE REQ.
Defi/CSI Criteria
A Maximum Reactions (Ibs)
PP Deflection in loc L/deft L/#
Gravity Non -Gravity
VERT(LL): 0.047 G 999 360
Loc R+ / R- / Rh / Rw /U / RL
VERT(CL): 0.088 G 999 240
B 818 /_ /_ /468 /357 1151
HORZ(LL): 0.019 G -
F 719 /- /- /377 /302 /-
HORZ(TL): 0.036 G
Wind reactions based on MWFRS
Creep Factor: 2.0
B Brg Width = 8.0 Min Req = 1.5
Max TC CSI: 0.362
F Brg Width = 3.8 Min Req = 1.5
Max BC CSI: 0.975
Bearings B & F are a rigid surface.
Bearings B & F require a seat plate.
Max Web CSI: 0.231
Maximum Top Chord Forces Per Ply (Ibs)
Wgt:85.4lbs
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver: 19.01.00A.0618.16
A - B 39 0 D - E 612 -1230
B -C 515 -1301 E -F 499 -1251
C - D 630 -1287
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - I 1114 -407 H - G 693 -209
I - H 693 -209 G - F 1062 -392
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C-1 245 -253 D - G 483 -217
I- D 547 -238 G - E 240 -235
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
C—driht n 201A A-1 Rnnf Tn1.SSaC– Renrntinrtinn of this in anv fnnn. is nrohihMA wAlhnuf the written narmicainn of A-1 Rnnf T.i .,.
Job Truss Truss Type Qty I Ply 07/13/2020
ARMSCM1560BlL C01 HIPM 1 1 2572
409#186# 186#
F-- 7'0"6 +. 2,0"6 T 2, t
11"
I-- 7'
4'11'12 +I
SEAT PLATE REQ. SEAT PLATE REQ.
i. 11'11"12 i
h- 1'5"9 -"I
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field It 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
C.-noht 0 2016 A-1 Ronf Tnic - Ronmdnnfinn of this dncement in env fernis ornhihited withnuf the wnttnn nonnission of A-1 Roof Tmeses.
b 111# 4
582# 111#
Loading Criteria (psf) Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TOLL: 20.00 Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.029 F 999 360
Loc R+ 1 R- / Rh / Rw /U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Varies by Ld C I6tRT(CL): 0.053 F 999 240
B 1027 /- !- /- /509 /-
BCDL: 7.00 Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.009 E - -
E 1370 /- /- /- /675 /-
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.017 E
Wind reactions based on MWFRS
Des Ld: 37.00 Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
g q B Br Width = 8.0 Min Re 1.5
NCBCLL: 10.00 TCDL: 5.0 psf
Max TC CSI: 0.769
E BrWidth = 3.8 Min Re1.6
9 q =
Load Duration: 1.25 BCDL: 4.2 sf
p
Bearings B & E are a rigid surface.
Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2
Max BC CSI: 0.977
Bearings B & E require a seat plate.
C&C Dist a: 3.00 ft
Max Web CSI: 0.385
Maximum Top Chord Forces Per Ply (Ibs)
Loc. from endwall: not in 4.50
Wgt: 65.8 Ibs
Chords Tens.Comp. Chords Tens. Comp.
GCpi: 0.18
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.16
A - B 39 -26 C - D 12 -18
Lumber
B - C 774 -1573
Top chord 2x4 SP #2 :T2 2x4 SP M-30:
Bot chord 2x6 SP #2
Maximum Bot Chord Forces Per Ply (Ibs)
Webs 2x4 SP #3
Chords Tens.Comp. Chords Tens. Comp.
Bracing
B - F 1317 -631 F - E 1351 -637
(a) Continuous lateral restraint equally spaced on member.
Maximum Web Forces Per Ply (lbs)
Special Loads
Webs Tens.Comp. Webs Tens. Comp.
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
C - F 806 -145 D - E 252 -318
TC: From 62 plf at -1.46 to 62 pit at 7.00
C - E 762 -1625
TC: From 31 plf at 7.00 to 31 pif at 11.98
BC: From 14 pif at 0.00 to 14 pif at 7.03
BC: From 7 plf at 7.03 to 7 plf at 11.98
TC: 409 Ib Conc. Load at 7.03
TC: 186 Ib Conc. Load at 9.06,11.06
BC: 582 Ib Conc. Load at 7.03
BC: 111 Ib Conc. Load at 9.06,11.06
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 7.00 11.98
BC 101 0.15 11.98
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Right end vertical not exposed to wind pressure.
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field It 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
C.-noht 0 2016 A-1 Ronf Tnic - Ronmdnnfinn of this dncement in env fernis ornhihited withnuf the wnttnn nonnission of A-1 Roof Tmeses.
ARMSCM1560BlL ( CO2
,T3
HIPM
9'
— 2'11"12 —�{
SEAT PLATE REQ. SEAT PLATE REQ.
i 1'11"12
t!)
3407
1- 1'5"9 --{
Loading Criteria (psf) Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
A Maximum Reactions (lbs)
TCLL: 20.00 Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.036 F 999 360
Loc R+ / R- / Rh / Rw /U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.067 F 999 240
B 556 /- /- /366 /203 /265
BCDL: 7.00 Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.023 F - -
E 446 /- /- /256 /236 !-
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.042 F - -
Wind reactions based on MWFRS
Des Ld: 37.00 Mean Height: 25.00 ft
WAVE
Creep Factor: 2A
B Br Width = 8.0 Min Re 1.5
9 q
NCBCLL: 10.00 TCDL: 5.0 sf
p
Max TC CSI: 0.594
E Brg Width = 3.8 Min Req = 1.5
Load Duration: 1.25 BCDL: 4.2 psf
Max BC CSI: 0.982
Bearings B & E are a rigid surface.
Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2
Bearings B & E require a seat plate.
C&C Dist a: 3.00 ft
Max Web CSI: 0.252
Maximum Tap Chord Forces Per Ply (Ibs)
Loc. from endwall: not in 9.00
Wgt:58.8lbs
Chords Tens.Comp. Chords Tens. Comp.
GCpi: 0.18
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.16
A - B 39 0 C - D 0 0
Lumber
B - C 73 -413
Top chord 2x4 SP 2400f-2.OE :T2 2x4 SP #2:
Bot chord 2x4 SP #2
Maximum Bot Chord Forces Per Ply (Ibs)
Webs 2x4 SP #3
Chords Tens.Comp. Chords Tens. Comp.
Purlins
B - F 254 -167 F - E 260 -167
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Maximum Web Forces Per Ply (lbs)
Chord Spacing(in oc) Start(ft) End(ft)
Webs Tens.Comp. Webs Tens. Comp.
TC 24 9.00 11.98
C - F 309 0 D - E 89 -92
BC 111 0.15 11.98
Apply purlins to any chords above or below fillers
C - E 304 -474
at 24" OC unless shown otherwise above,
Wind
Wind loads based on MWFRS with additional C&C member design
Right end vertical not exposed to wind pressure.
-WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedri
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1, The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
0,n,n,ht a 2016 A-1 Roof Tm<ta_s – Renfodnfdfon of this docnment. in env formi,¢ orohihitad v,ithont the WHften nonni.-ion of A-1 Rnnf Trux on
Job Truss Truss Type QtyPly 07/13/2020
ARMSCM1560Bl L CO3 MONO 12 I 1 I 3401
4'3
rel
SEAT PLATE REQ. SEAT PLATE REQ.
11'11"12
1,5,9
Loading Criteria (pst) Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.011 F 999 360
Loc R+ / R- / Rh / Rw /U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.020 F 999 240
B 556 /- /- /363 /168 /343
BCDL: 7.00 Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.005 E - -
E 446 /- /- /299 /267 /-
EXP: B Kzt: NA
Des 37.00
Plate Type(s):
HORZ(TL): 0.009 E
Wind reactions based on MWFRS
Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
B Brg Width = 8.0 Min Req = 1.5
NCBCLL: 10.00 TCDL: 5.0 psf
Max TC CSI: 0.568
E Br Width = 3.8 Min Re 1.5
9 q =
Load Duration: 1.25 BCDL: 4.2 psf
Bearings B & E are a rigid surface.
Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2
Max BC CSI: 0.974
Bearings B & E require a seat plate.
C&C Dist a: 3.00 ft
Max Web CSI: 0.443
Loc. from endwall: not in 9.00
Maximum Top Chord Forces Per Ply (Ibs)
GCpi: 0.18
Wgt: 61.6 lbs
Chords Tens.Comp. Chords Tens. Comp.
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.16
A - B 39 0 C - D 60 -102
Lumber
B - C 90 -625
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Maximum Bot Chord Forces Per Ply (Ibs)
Webs 2x4 SP #3
Chords Tens.Comp. Chords Tens. Comp.
Purlins
B - F 495 -299 F - E 493 -300
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Maximum Web Forces Per Ply (Ibs)
Chord Spacing(in oc) Start(ft) End(ft)
Webs Tens.Comp. Webs Tens. Comp.
BC 119 0.15 11.98
Apply purlins to any chords above or below fillers
F - C 238 0 D - E 166 -135
at 24" OC unless shown otherwise above.
C - E 346 -567
Wind
Wind loads based on MWFRS with additional C&C member design
Right end vertical not exposed to wind pressure.
*'WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seat on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
CnnvHnht 0 2W A-1 Roof Tnicse-s – Ronrodnofinn of thia dnrm—nf, in anv forn. m nmhihilod WthmR the wditsn nanniaaion of A-1 Roof Tru—
Job Truss
ARMSCM1560BlL I E01
Truss Type
GABL
j- 4'6"
Qty Ply 07/13/2020
1 1
{- 4'6" —i
F///4X8(R1)
r1,Q„8 6'11” 7=—
2514
1,5, 9
g'
t 1'5"9
Loading Criteria (psi) Wind Criteria Code / Misc Criteria
Defl/CSI Criteria
A Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
Gravity
Non -Gravity
TCDL: 10.00 Speed: 160 mph TPI Std: 2014
VERT(LL): -0.062 B 255 360
Loc R+ / R- / Rh
/ Rw
/U / RL
BCLL: 0.00 Enclosure: Closed Rep Factors Used: Varies by Ld
C %eERT(CL): 0.058 J 275 240
R 938 /- /-
/556
/600 /274
BCDL: 7.00 Risk Category: 11 FT/RT:10(0)/10(10)
HORZ(LL):-0.034 B - -
N 938 /- /-
/463
/610 /-
EXP: B Kzt: NA Plate Type(s):
HORZ(TL): 0.036 B
Wind reactions based on
MWFRS
Des Ld: 37.00 Mean Height: 25.00 ft WAVE
Creep Factor: 2
R Br Width = 3.5
9
Min Req
= 1.5
NCBCLL: 10.00 TCDL: 5.0 sf
p
0.
Max TC CSI: 0.631
N Brg Width = 3.5
Min Req
= 1.5
Load Duration: 1.25 BCDL: 4.2 psf
Max BC CSI: 0.551
Bearings R & N are a rigid
surface.
Spacing: 24.0 " MWFRS Parallel Dist: > 2h
Max Web CSI: 0.353
Maximum Top Chord Forces Per
Ply (Ibs)
C&C Dist a: 3.00 ft
Tens.Comp.
Chords
Tens. Comp.
Loc. from endwall: not in 9.00Chords
Wgt: 91.0 Ibs
GCpi: 0.18
A- B 82 0
F- G
346 -73
Wind Duration: 1.60
VIEW Ver: 19.01.00X0618.16
B - C 121 -53
G - H
296 -83
C - D 137 -33
H -1
115 0
Lumber
D - E 265 -126
I - J
102 -18
Top chord 2x4 SP #2
E - F 368 -109
J - K
82 0
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Maximum Bot Chord Forces Per Ply (lbs)
Plating Notes
Chords Tens.Comp.
Chords
Tens. Comp.
All plates are 1.5X3 except as noted.
T - S 78 -67
P-0
165 -119
S -R 78-66
O -N
165 -119
Purlins
R -Q 165 -119
N -M
56 -30
In lieu of structural panels or rigid ceiling use purlins
Q - P 165 -119
M - L
58 -31
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.00 9.00
Maximum Web Forces
Per Ply (Ibs)
Apply purlins to any chords above or below fillers
Webs Tens.Comp.
Webs
Tens. Comp.
at 24" OC unless shown otherwise above.
B - T 267 -158
F - W
127 -245
Loading
D - R 527 -406
X - N
160 -260
Truss designed to support 2-0-0 top chord outlookers and cladding load not to
R - U 113 -244
V - F 104 -252
N - H
J - L
530 -406
276 -156
exceed 8.00 PSF one face and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Maximum Gable Forces Per Ply (Ibs)
Wind
Gables Tens.Comp.
Gables
Tens. Comp.
Wind loads based on MWFRS with additional C&C member design.
C -S 57 -63
W -G
167 -160
Left end vertical exposed to wind pressure. Deflection meets L/360.
U - Q 175 -165
O - X
147 -165
Right end vertical not exposed to wind pressure.
E - V 188 -160
M -1
59 -71
Left and right cantilevers are exposed to wind
P - F 112 -123
Left bottom chord exposed to wind.
Additional Notes
See STD DETAILS for gable wind bracing requirements
"WARNING`* Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 Sl, Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
C:nnvrinht n 2016 AA Ronf TnICSP_S - Renrotlnrtinn of thix dmument, in anv formis nrohihite.d withmit the Written narmisxinn of AA Roof T.—a,
Job Truss
IARMSCM1560BlL E02
1
Truss Type
COMM
Qty I Ply 07/13/2020
4 1
i- 4,6„1 4,6„ —�
D= -4X4
N
1 0 8 6'11" i
1'0116
�-- 1'5"9 1 9'1 1'5"9 ---
2587
Loading Criteria (psf) Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl L/# Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): -0.027 F
592 360 Loc R+ / R- / Rh / Rw /U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.038 F
419 240 J 454 !- /- /362 /199 /172
BCDL: 7.00 Risk Category: 11
FT/RT:10(0)/10(10)
HORZ(LL): 0.014 F
- - 1 454 /- /- /262 /96 /-
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.019 F
Wind reactions based on MWFRS
Des Ld: 37.00 Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
J Brg Width = 3.5 Min Req = 1.5
NCBCLL: 10.00 TCDL: 5.0 sf
p
Max TC CSI: 0.434
1 Brg Width = 3.5 Min Req = 1.5
Load Duration: 1.25 BCDL: 4.2 psf
Bearings J & I are a rigid surface.
Spacing: 24.0 " MWFRS Parallel Dist: > 2h
Max BC CSI: 0.464
Max Web CSI: 0.195
Maximum Top Chord Forces Per Ply (Ibs)
C&C Dist a: 3.00 ft
Chords Tens.Comp. Chords Tens. Comp.
Loc. from endwall: not in 9.00Wgt:
65.8 Ibs
GCpi: 0.18
A -B 39 0 D - E 161 -44
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.16
B - C 60 -54 E - F 60 -23
Lumber
C- D 193 -89 F- G 39 0
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Maximum Bot Chord Forces Per Ply (Ibs)
Webs 2x4 SP #3
Chords Tens.Comp. Chords Tens. Comp.
Purlins
K -J 75 -48 1-H 38 -17
J - 1 78 -61
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
Maximum Web Forces Per Ply (lbs)
BC 75 0.00 9.00
Webs Tens.Comp. Webs Tens. Comp.
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
B - K 167 -113 D - 1 75 -125
C - J 314 -234 1- E 342 -234
Wind
J -D 82 -125 F -H 87 -66
Wind loads based on MWFRS with additional C&C member
design.
Left end vertical exposed to wind pressure. Deflection
meets L/360.
Right end vertical not exposed to wind pressure.
Left and right cantilevers are exposed to wind
Left bottom chord exposed to wind.
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineer"
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms areas defined in TPI -1.
(;—n.ht n 2016 A-1 Rnnf Tnicsr_s - Renrodudinn of this doonnent in anv fnnn. is nmhihitnd mthnut thn written of AA Rnnf Tni—
Jou,11 VJJ I ruJ. I YP-
ARMSCM1560B1L E03 I COMN
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
i 4'0"8
1 o C= -4X4
4'0"8 —{
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL• 4.2 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 97 0.00 8.08
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
F15 6'11" I 1 y
8'0"15
V l 11J 111
X3
1111.5X3
K3
2511
Code ! Misc Criteria
Defl/CSI Criteria
A Maximum Reactions (lbs)
Code:FBC 2017 RES
PP Deflection in loc L/deft L/#
Gravity Non -Gravity
TPI Std: 2014
VERT(LL): -0.011 F 933 360
Loc R+ / R- / Rh / Rw /U / RL
H 304 !- /0 /225 /130 /133
Rep Factors Used: Yes
VERT(CL): -0.015 F 999 240
FT/RT:10(0)/10(10)
HORZ(LL): -0.007 A - -
G 317 /- /- /222 /86 /-
Plate Type(s):
HORZ(TL): 0.011 A
Wind reactions based on MWFRS
WAVE
Creep Factor: 2.0
H Erg Width = 3.5 Min Req = 1.5
Max TC CSI: 0.260
G Erg Width = 3.5 Min Req = 1.5
Max BC CSI: 0.379
Bearings H & G are a rigid surface.
Max Web CSI: 0.199
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
Wgt: 60.2 Ibs
A - B 49 -91 C - D 109 -47
VIEW Ver: 19.01.00A.0618.16
B - C 162 -83 D - E 75 -67
Wind
Wind loads based on MWFRS with additional C&C member design.
Left end vertical exposed to wind pressure. Deflection meets L/360.
Right end vertical not exposed to wind pressure.
Left and right cantilevers are exposed to wind
Left bottom chord exposed to wind.
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
I - H 166 -157 G -F 9 -17
H - G 80 -43
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp.
Webs Tens. Comp.
A-1
129 -136
C -G 99 -132
B - H
246 -109
G - D 275 -132
H -C
128 -126
E - F 127 -133
-WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
(', n nnht n 2016 A-1 in anv formRnnf Tn1.c¢ns
Job
ARMSCM1560Bl L
Truss Truss Type QtyPly
E04 GAEL 11 11
f'_ 3,9„4 3,9„4
12
6 F:71- C/A4X10(R1)
J
=3X3 I H G =3X3
SEAT PLATE REQ.
7'6"8
07/13/2020
3456
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (lbs), or "=PLF
TCLL: 20.00
Wind Std: ASCE 7-10
Code:FBC 2017 RES
PP Deflection in loc L/deft
L/# Gravity Non -Gravity
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.001 B 999
360 Loc R+ / R- / Rh / Rw /U / RL
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.002 B 999
240 J* 72 /_ /_ /39 /12 /7
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.001 D -
- O 78 /- /- /73 /35 /-
Des Ld: 37.00
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.002 D
Wind reactions based on MWFRS
Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
J Br Width = 83.3 Min Re -
9 q -
NCBCLL: 10.00
TCDL: 5.0 psf
Max TC CSI: 0.068
O Erg Width = 7.2 Min Req = 1.5
Load Duration: 1.25
BCDL: 4.2 psf
Bearings J & O are a rigid surface.
Spacing: 24.0 "
MWFRS Parallel Dist: h to 2h
Max BC CSI: 0.027
Bearing O requires a seat plate.
C&C Dist a: 3.00 ft
Max Web CSI: 0.059
Loc. from endwall: not in 9.00
Maximum Top Chord Forces Per Ply (Ibs)
Wgt: 100.8 lbs
Chords Tens.Comp. Chords Tens. Comp.
GCpi: 0.18
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.16
A- B 33 -18 C - D 126 -30
Lumber
B - C 126 -30 D - E 33 -18
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Maximum Bot Chord Forces Per Ply (Ibs)
Webs 2x4 SP #3
Chords Tens.Comp. Chords Tens. Comp.
Bracing
J - 1 29 -22 H - G 29 -22
(a) Continuous lateral restraint equally spaced on member.
I - H 29 -22 G - F 29 -99
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 90 0.00 7.54
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
End verticals not exposed to wind pressure.
Additional Notes
See STD DETAILS for gable wind bracing requirements.
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp.
Webs
Tens. Comp.
A - J
54 -40
C - M
50 -66
J - K
54 -69
N - F
50 -66
L - C
53 -70
E - F
54 -40
Maximum Gable Forces Per Ply (Ibs)
Gables Tens.Comp. Gables Tens. Comp
K -I 201 -145 M -D 195 -140
B -L 195 -140 G -N 201 -145
H -C 0 -45
'*WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristem, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field d 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
Cnnvdaht n 2016 A-1 Rnnf Tnicve.G – Renmdnntion of thi[ i--nt in anv formi. nrohihited tvlthout the written narmi-ion of A.1 Rmf Tn ns
Job Truss
ARMSCM1560BlL I GE01
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: 11
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 25.00 ft
NCBCLL: 10.00
TCDL 5.0 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Plating Notes
All plates are 2X4(D8R) except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in
oc) Start(ft) End(ft)
BC 32
0.00 2.67
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Truss Type Qty Ply 07/13/2020
EJAC 1 1
1 7"2 } 2-0-14
—�
12
6 1111.5X38
M
d'
A
CE
1111.5X4
D
SEAT Pl1c9T&TRHaTE5RBQPLATE REQ.
—^J-- 1'8" ----i
i
2-4"8
—__— 2,8° -
Code / Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Wind
Wind loads based on MWFRS with additional C&C member design.
Defl/C51 Criteria
PP Deflection in loc L/deft L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.000 C
HORZ(TL): 0.000 C
Creep Factor: 2.0
Max TC CSI: 0.105
Max BC CSI: 0.029
Max Web CSI: 0.051
Wgt: 9.8 lbs
VIEW Ver: 19.01.00A.0618.16
2533
A Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- ! Rh / Rw / U / RL
A 106 /- /- /37 /10 136
D 47 /- 1- /18 /- /-
E 84 /- /- /54 132 /-
Wind reactions based on MWFRS
A Brg Width = 8.0 Min Req = 1.5
D Brg Width = 8.0 Min Req = 1.5
E Brg Width = 16.0 Min Req = 1.5
Bearings A, D, & D are a rigid surface.
Bearings A, D, & D require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-13 25 -58
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A -C 9 -13
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
B -C 110 -74
-WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms areas defined in TPI -1.
('n vrinht n 201 E A -i In anv form. is nmhihited wilhntit thn wdHnn nnrtnis[inn of A•1 Rnnf T,,cc
Job Truss
ARMSCM1560BlL HR
Truss Type City Ply
HIP_ 12 1
-25# 255#
129#
�-- 1,5.8 4__ 2'9"15 --t-- 2'9"15 - - 2'8"11 ------
D
D
07/13/2020
SEAT PLATE REQ.
9110"1 -I
2590
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI. 1.
(;nnvrioht n 2016 A-1 Ronf Tn, ce - Renrodnntinn of thio dnrnment in nnv form is nrnhihlled withnnl the wditen nnrmis<inn of A-1 Ronf Tmecea
+
10#
86# d 4
155#
Loading Criteria (pst) Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.021 F 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Varies by Ld C ktRT(CL): 0.053 F 999 240
B 321 /- /- /- /258 /-
BCDL: 7.00 Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.009 F - -
E 331 /- /- /- /133 /-
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.022 F
D 68 /- /- /- /55 /-
Des Ld: 37.00 Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
NCBCLL: 10.00 TCDL: 5.0 psf
Max TC CSI: 0.520
B Brg Width = 1 Min Req = 1.5
Load Duration: 1.25 BCDL: 4.2 psf
"
Max BC CSI: 0.619
E Brg Width = 1.5 5 Min Req = -
.
Spacing: 24.0 MWFRS Parallel Dist: 0 to h/2
D Brg Width = 1.5 Min Req = -
C&C Dist a: 3.00 ft
Max Web CSI: 0.264
Bearing B is a rigid surface.
Loc. from endwall: not in 4.50
Wgt: 39.2 lbs
Bearing B requires a seat plate.
GCpi: 0.18
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.16
Chords Tens.Comp. Chords Tens. Comp.
Lumber
A-13 19 -13 C - D 50 -66
Top chord 2x4 SP #2
B - C 400 -494
Bot chord 2x4 SP M-30
Webs 2x4 SP #3
Maximum Bot Chord Forces Per Ply (Ibs)
Special Loads
Chords Tens.Comp. Chords Tens. Comp.
-----(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
B - F 487 -352 F - E 0 0
TC: From 0 plf at -1.98 to 61 plf at -0.10
TC: From 2 plf at -0.10 to 2 pif at 9.84
BC: From 2 plf at 0.00 to 2 plf at 9.84
Maximum Web Forces Per Ply (Ibs)
TC: -25 Ib Cone. Load at 1.46
Webs Tens.Comp.
TC: 129 Ib Cone. Load at 4.29
TC: 255 Ib Cone. Load at 7.12
C - F 382 -529
BC: 10 Ib Cone. Load at 1.46
BC: 86 Ib Cone. Load at 4.29
BC: 155 Ib Cone. Load at 7.12
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 116 0.15 9.84
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI. 1.
(;nnvrioht n 2016 A-1 Ronf Tn, ce - Renrodnntinn of thio dnrnment in nnv form is nrnhihlled withnnl the wditen nnrmis<inn of A-1 Ronf Tmecea
JouUJJ
ARMSCM1560BlL H" J'7'
,.Aty I rry
1 1
U 11 1 a/GULU
-25# 101# 146#
1299
7#
1,5„8 -�_ 2,9„15 - - 1,7„ 1'2' 16 10"8 '4-1'10"2
I
SEAT PLATE REQ.
1^-1'11"13 -^1 9110"1
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
129 Ib Cone. Load at 4.29
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 25.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
WAVE
C&C Dist a: 3.00 ft
10 Ib Cone. Load at 1.46
Loc. from endwall: not in 4.50
BC:
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP M-30
Bot chord 2x6 SP #2
Webs 2x4 SP #3
Special Loads
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 61 plf at -1.98 to
61 plf at 1.46
TC: From 31 plf at 1.46 to
31 plf at 9.84
BC: From 7 plf at 0.00 to
7 pif at 9.84
TC:
-25 Ib Cone. Load at 1.46
TPI Std: 2014
TC:
129 Ib Cone. Load at 4.29
G 640 /- /- A /465 /-
TC:
101 Ib Cone. Load at 5.87
FT/RT:10(0)/10(10)
TC:
127 Ib Cone. Load at 7.12
Plate Type(s):
TC:
146 Ib Cone. Load at 7.99
WAVE
BC:
10 Ib Cone. Load at 1.46
BC:
86 Ib Cone. Load at 4.29
BC:
62 Ib Cone. Load at 5.87
BC:
77 ib Cone. Load at 7.12
BC:
88 ib Cone. Load at 7.99
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 99 0.15 9.84
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
2569
8 b
86# 77#
10# 624 884
Code / Misc Criteria
Defl/CSI Criteria
A Maximum Reactions (Ibs)
Code: FBC 2017 RES
PP Deflection in loc L/deft L/#
Gravity Non -Gravity
TPI Std: 2014
VERT(LL): 0.032 C 999 360
Loc R+ / R- / Rh / Rw / U / RL
G 640 /- /- A /465 /-
Rep Factors Used: Varies by Ld C
kq--RT(CL): 0.057 C 999 240
FT/RT:10(0)/10(10)
HORZ(LL): 0.008 C - -
E 471 /- /0 /- /173 /-
Plate Type(s):
HORZ(TL): 0.014 C
D 223 /- /- A /181 !-
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TC CSI: 0.554
G Brg Width = 10.6 Min Req = 1.5
Max BC CSI: 0.993
E Brg Width = 1.5 Min Req = -
Max Web CSI: 0.680
D Erg Width = 1.5 Min Req = -
Bearing G is a rigid surface.
Wgt: 49.0 Ibs
Bearing G requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
VIEW Ver: 19.01.00A.0618.16
Chords Tens.Comp. Chords Tens. Comp.
A -B 39 -27 C -D 121 -150
B - C 822 -1065
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B- F 1044 -756 F- E 0 0
Maximum Web Forces Per Pty (Ibs)
Webs Tens.Comp.
C - F 784 -1082
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
Convrinht 0 2016 A-1 Rnnf Tru.-- Renrnrinotion of thin rinnnmenl in nnv form. is nrohihi A without thn w6"t no h-lon of A•1 Rnnf Tnjce
Job Truss
ARMSCM156OBlL HJ7B
T
Truss Type Qty Ply
HIP_ 1 1
07/13/2020
-25# 260#
} 140#
I-- 1,5"8.4__ 2'9"15 - t 2'9"15 - -- 2'8"11 --�
17
�- 1'11"13
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
TC: 260 Ib Conc. Load at 7.12
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 25.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
WAVE
C&C Dist a: 3.00 ft
Wind reactions based on MWFRS
Loc. from endwall: not in 9.00
Max TC CSI: 0.533
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP M-30
Webs 2x4 SP #3
Special Loads
-----(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 0 plf at -1.98 to
61 plf at -0.10
TC: From 2 pif at -0.10 to
2 pif at 9.84
BC: From 2 pif at 0.00 to
2 pif at 9.84
TC: -25 Ib Conic. Load at 1.46
Gravity Non -Gravity
TC: 140 Ib Conc. Load at 4.29
VERT(LL): 0.021 F 999 360
TC: 260 Ib Conc. Load at 7.12
B 321 /- /- /- /264 /-
BC: 10 Ib Conc. Load at 1.46
kPERT(CL): 0.053 F 999 240
BC: 86 Ib Conc. Load at 4.29
HORZ(LL): 0.009 F - -
BC: 153 Ib Conc. Load at 7.12
Plate Type(s):
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 116 0.15 9.84
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
SEAT PLATE REQ.
9'10"1
3463
i 86# 4
10# 153#
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TPI Std: 2014
VERT(LL): 0.021 F 999 360
Loc R+ / R- / Rh / Rw / U / RL
B 321 /- /- /- /264 /-
Rep Factors Used: Varies by Ld C
kPERT(CL): 0.053 F 999 240
FT/RT:10(0)/10(10)
HORZ(LL): 0.009 F - -
E 337 /- /- /- /139 !-
Plate Type(s):
HORZ(TL): 0.022 F
D 69 /- /- /- /57 /-
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TC CSI: 0.533
B Brg Width = 10.6 Min Req = 1.5
Max BC CSI: 0.618
E Brg Width = 1.5 Min Req = -
Max Web CSI: 0.274
D Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Wgt: 39.2 lbs
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
VIEW Ver: 19.01.00A.0618.16
Chords Tens.Comp. Chords Tens. Comp.
A -B 19-13 C -D 52 -67
B - C 419 - 513
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B- F 505 ,-369 F- E 0 0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
C - F 401 -548
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, RE,
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
(:nnvnoht n 2016 A-1 Roof TnissP_s - Renrndnolm of lhi.,Anrnmf!nt. in anv to- i< prohibited without the wnften nenniceinn of A-1 Roof Tne,& . .
Jon rU55
ARMSCM1560BlL HJ76P
T
4'3
trues type
HIP_
Wfy I My
1 1
-25# 255#
129#
�-- 1'5"8 -�-- 2'9"15 -- - 2'91,15 -- ^- 2'8"11 ------
710
7
f--- 1'11"13
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
TC: 255 Ib Cone. Load at 7.12
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 25.00 ft
NCBCLL• 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
WAVE
C&C Dist a: 3.00 ft
Wind reactions based on MWFRS
Loc. from endwall: not in 4.50
Max TC CSI: 0.520
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP M-30
Webs 2x4 SP #3
Special Loads
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 0 plf at -1.98 to
61 plf at -0.10
TC: From 2 plf at -0.10 to
2 plf at 9.84
BC: From 2 plf at 0.00 to
2 plf at 9.84
TC: -25 Ib Cone. Load at 1.46
Gravity Non -Gravity
TC: 129 Ib Cone. Load at 4.29
VERT(LL): -0.035 F 999 360
TC: 255 Ib Cone. Load at 7.12
B 321 I- 1- /- /320 /-
BC: 10 Ib Cone. Load at 1.46
%q-=RT(CL): 0.053 F 999 240
BC: 86 Ib Cone. Load at 4.29
HORZ(LL): -0.014 F - -
BC: 155 Ib Cone. Load at 7.12
Plate Type(s):
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 116 0.15 9.84
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Left bottom chord exposed to wind.
SEAT PLATE REQ.
9'10"1
2499
8 b 4
10# 86# 155#
Code / Misc Criteria
Defl/CSI Criteria
A Maximum Reactions (lbs)
Code: FBC 2017 RES
PP Deflection in loc L/deft L/#
Gravity Non -Gravity
TPI Std: 2014
VERT(LL): -0.035 F 999 360
Loc R+ / R- / Rh / Rw ! U / RL
B 321 I- 1- /- /320 /-
Rep Factors Used: Varies by Ld C
%q-=RT(CL): 0.053 F 999 240
FT/RT:10(0)/10(10)
HORZ(LL): -0.014 F - -
E 331 !- / /- /257 /-
Plate Type(s):
HORZ(TL): 0.022 F
D 68 /- /- /- /45 /-
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TC CSI: 0.520
B Brg Width = 10.6 Min Req = 1.5
Max BC CSI: 0.967
E Brg Width = 1.5 Min Req = -
Max Web CSI: 0.264
D Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Wgt: 39.2 lbs
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
VIEW Ver: 19.01.00A.0618.16
Chords Tens.Comp. Chords Tens. Comp.
A -B 19-13 C -D 52 -66
B - C 452 -494
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - F 487 -412 F -E 0 0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
C - F 447 -529
"WARNING`" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
C-H.ht 0 2016 A -t Ronf Tnisse.¢- Renrndnrdinn of thi[ dnnn-tin anv fnrm. is nrnhihited Wlhnut tha wnHen nenni-inn of A-1 Rnnf Tni.¢ees
Job
ARMSCM1560Bl L
1
Truss Truss Type
J 1 I JACK
12 C
6 I
4"3
1
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: it
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 25.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) Eri
BC 10 0.15 1.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Qty I Ply 07/13/2020
8 1
SEAT PLATE REQ.
1,5°9_ 1,
Code / Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Wind
Wind loads based on MWFRS with additional C&C member design.
Defl/CSI Criteria
PP Deflection in loc L/deft L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): -0.000 D
HORZ(TL): 0.000 D
Creep Factor: 2.0
Max TC CSI: 0.346
Max BC CSI: 0.046
Max Web CSI: 0.000
Wgt: 5.6 lbs
VIEW Ver: 19.01.00A.0618.16
2593
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 218 /- /- /196 /115 /57
D 5 /-14 /- /19 /17 /-
C - /40 /- /44 /50 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp. Chords Tens. Comp.
A- B 39 0 B- C 68 -33
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B -D 0 0
'"WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
Convrinht n 2nM A-1 m —form Rnof Tmeses
popurs
ARMSCM1560BlL J1P
4"3
Loading Criteria (psf)
Wind Criteria
TOLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 25.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc, from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in
oc) Startift) End(ft)
BC 10
0.15 1.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
I Cuss I ype Qty _1yU// I3/4
ULU
JACK 1 2 1 1
12 C
6 � -F
2X4(A1) B co
CD
r
A D
SEAT PLATE REQ.
1'5"9
Code / Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Wind
Wind loads based on MWFRS with additional C&C member design.
Left bottom chord exposed to wind.
2487
Defi/CSI Criteria A Maximum Reactions (Ibs)
PP Deflection in loc L/deft L/# Gravity Non -Gravity
VERT(LL)- NA Loc R+ / R- / Rh / Rw /U / RL
VERT(CL): NA
HORZ(LL): -0.000 D
HORZ(TL): 0.000 D
Creep Factor: 2.0
Max TC CSI: 0.346
Max BC CSI: 0.043
Max Web CSI: 0.000
Wgt: 5.6 lbs
VIEW Ver: 19.01.00A.0618.16
B 218 /- /- /206 /116 /57
D 5 /-14 /- /16 /9 /-
C - /40 /- /41 /54 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens, Comp.
A -B 39 0 B -C 67 -33
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B -D 0 0
-WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT"form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
Convdnht 0 2W A-1 Roof T --o., — Ronraduotion of IhN daa,mnt. In nnv farm. is nrohibited without the wninon nenniWon of A-1 Roof TmSGP
Job Truss Truss Type Qty Ply 07/13/2020
ARMSCM1560B1L J3 I JACK 17 1 2596
T
C
T
SEAT PLATE REQ.
3'
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in Ioc L/defl L/#
Gravity Non -Gravity
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
VERT(LL): NA
Loc R+ / R- / Rh 1 Rw / U / RL
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): NA
B 233 /- /- /179 /93 /109
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.001 D
D 43 !- /- /20 /-
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.001 D
C 64 /- /- /34 /56 /-
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
NCBCLL: 10.00
TCDL: 5.0 sf
p
Max TC CSI: 0.389
B Brg Width = 8.0 Min Req = 1.5
Load Duration: 1.25
BCDL: 4.2 psf
D Brg Width = 1.5 Min Req = -
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
Max BC CSI: 0.064
C Brg Width = 1.5 Min Req = -
C&C Dist a: 3.00 ft
Max Web CSI: 0.000
Bearing B is a rigid surface.
Loc. from endwall: Any
Wgt: 11.2 lbs
Bearing B requires a seat plate.
GCpi: 0.18
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.16
Chords Tens.Comp. Chords Tens. Comp.
Lumber
A - B 39 0 B - C 29 s 87
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Maximum Bot Chord Forces Per Ply (Ibs)
Purlins
Chords Tens.Comp.
In lieu of structural panels or rigid ceiling use purlins
B - D 0 0
to laterally brace chords as follows:
Chord Spacing(in
oc) Start(ft) End(ft)
BC 34
0.15 3.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design
**WARNING`* Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI.1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
C.nnvrinht nc MIR A-1 in anv fnnn. i[ nrohihirnd t0thnnl fhe wdflt..n nnnnisxian of A-1 Rnnf Tnicses.
Job
ARMSCM1560B1 L
Truss Truss Type
J3A JACK
T
6"5
I
3X4(B1)
Qty IPly
107/13/2020
Q
12 B
c r�
i
SEAT PLATE REQ.
3434
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design
**WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
1--11 n lol.e 1 -f Tnic - of fh Anr„ t in—form i, nrnhihilod wilhnnt tha.wniton nonniasion of AA Roof Token,
-2'7"12- °1
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
A Maximum Reactions (Ibs)
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBG 2017 RES
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
VERT(LL): NA
Loc R+ / R- / Rh / Rw / U / RL
A 105 /- /- 161 120 /67
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): NA
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): -0.001 B -
C 43 /- /- /20 /-
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.001 C
B 76 /- /- /46 /67 /-
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
NCBCLL: 10.00
TCDL: 5.0 psf
Max TC CSI: 0.196
A Erg Width = 3.8 Min Req = 1.5
Load Duration: 1.25
BCDL: 4.2 psf
Max BC CSI: 0.064
C Brg Width = 1.5 Min Req = -
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
B Brg Width = 1.5 Min Req = -
C&C Dist a: 3.00 ft
Max Web CSI: 0 000 .
Bearing A is a rigid surface.
Loc. from endwall: Any
Wgt: 9.8 Ibs
Bearing A requires a seat plate.
GCpi: 0.18
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.16
Chords Tens.Comp.
Lumber
A - B 34 -96
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Maximum Bot Chord Forces Per Ply (lbs)
Purlins
Chords Tens.Comp.
In lieu of structural panels
or rigid ceiling use purlins
A - C 0 0
to laterally brace chords as follows:
Chord Spacing(in
oc) Start(ft) End(ft)
BC 30
0.09 2.65
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design
**WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
1--11 n lol.e 1 -f Tnic - of fh Anr„ t in—form i, nrnhihilod wilhnnt tha.wniton nonniasion of AA Roof Token,
Job Truss Truss Type Qty Ply 0711312020
2490
ARMSCM1560B1L J31P ( JACK 2 I 1 I
C
T
SEAT PLATE REQ.
�-- 1'5119 ole 3' --1
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
EXP: B Kzt: NA
Plate Type(s):
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 34 0.15 3.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Left bottom chord exposed to wind.
Defl/CSI Criteria ♦ Maximum Reactions (Ibs)
PP Deflection in loc L/deft L/# Gravity Non -Gravity
VERT(LL): NA I Loc R+ / R- / Rh / Rw /U / RL
VERT(CL): NA
HORZ(LL): 0.000 D
HORZ(TL): 0.001 D
Creep Factor: 2.0
Max TC CSI: 0.346
Max BC CSI: 0.065
Max Web CSI: 0.000
Wgt: 11.2 Ibs
VIEW Ver: 19.01.00A.0618.16
B 233 /- !- /215 /98 /109
D 43 /- !- /58 !30 /-
C 64 /- /- /37 /55 !-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A -B 39 0 B -C 29 -93
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B -D 0 0
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
Cnnvdnht 02n1e A-1 Roof Tniasx_v — Rpnrntinrtion of this dornmont in nnv torr,is nrohihilod withmit thr. Wdttnn omnia[ion of A-1 Roof Trncc
Job Truss Truss Type Qty I Ply 07/13/2020
ARMSCM1560BIL I J5 JACK 6 1 2599
T
SEAT PLATE REQ.
VY9 5'
C
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
A Maximum Reactions (Ibs)
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
VERT(LL): NA
Loc R+ / R- ! Rh / Rw / U / RL
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): NA
B 299 /- /- /213 /106 /161
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.004 D
D 77 /- /- /36 /-
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.008 D
C 127 /- /- /75 /107 /-
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
NCBCLL: 10.00
TCDL: 5.0 sf
p
Max TG CSI: 0.339
B Brg Width = 8.0 Min Req = 1.5
Load Duration: 1.25
BCDL: 4.2 psf
D Brg Width = 1.5 Min Req = -
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
Max BC CSI: 0.218
C Brg Width = 1.5 Min Req = -
C&C Dist a: 3.00 ft
Max Web CSI: 0.000
Bearing B is a rigid surface.
Loc. from endwall: not in 4.50
Wgt: 18.2 lbs
Bearing B requires a seat plate.
GCpi: 0.18
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.16
Chords Tens.Comp. Chords Tens. Comp.
Lumber
A - B 39 0 B - C 57 -107
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Maximum Bat Chord Forces Per Ply (Ibs)
Purlins
Chords Tens.Comp.
In lieu of structural panels
or rigid ceiling use purlins
B - D 0 0
to laterally brace chords as follows:
Chord Spacing(in
oc) Start(ft) End(ft)
BC 58
0.15 5.00
Apply purlihs to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design
*"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the content of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
Cnovdnht n 217116 AA Rnnf Tntxs — Renmdnnlinn of thm do .t m ,nf in anv form. ix nmhihited withnnt fhP wdttan n"rmictinn of A-1 Ronf Tntt¢ec
JUL, _1
ri
ARMSCM1560BlL J5A (JACKyMc 1y 11y
I
C
�— 1'5"9
SEAT PLATE REQ.
4'1 "7
2536
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00
Wind Std: ASCE 7-10
Code:FBC 2017 RES
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
VERT(LL): NA
Loc R+ / R- / Rh ! Rw / U / RL
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): NA
B 269 /- /- /197 /99 /138
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.002 D
D 62 /- /- /29 /-
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.004 D
C 101 /- /- /58 /85 /-
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
NCBCLL: 10.00
TCDL: 5.0 psf
Max TC CSI: 0.228
B Brg Width = 8.0 Min Req = 1.5
Load Duration: 1.25
BCDL: 4.2sf
P
Max BC CSI: 0.142
D Brg Width = 1.5 Min Req = -
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C Brg Width = 1.5 Min Req = -
C&C Dist a: 3.00 ft
Max Web CSI: 0.000
Bearing B is a rigid surface.
Loc. from endwall: not in 4.50
Wgt: 16.8 lbs
Bearing B requires a seat plate.
GCpi: 0.18
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.16
Chords Tens.Comp. Chords Tens. Comp.
Lumber
A - B 39 0 B - C 45 89
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Maximum Bot Chord Forces Per Ply (Ibs)
Purlins
Chords Tens.Comp.
In lieu of structural panels or rigid ceiling use purlins
B - D 0 0
to laterally brace chords as follows:
Chord Spacing(in
oc) Start(ft) End(ft)
BC 48
0.15 4.12
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any Feld # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -I.
Convnnht n 201E A.1 Roof Tni-es – Ranrodnrtino of This docmm,nt in onv fnnn. 1 nrohihit.d Wth-1 tha wnttnn nnnni-i- of A-1 Roof To—,
Job Truss Truss Type QtyPly 07/13/2020
ARMSCM1560BIL J5B JACK 1 11 3437
T
6"5
1
3X4(B1)
n.
SEAT PLATE REQ.
F 4r7"12 _ 1
0
r
N
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
A Maximum Reactions (Ibs)
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
VERT(LL): NA
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): NA
A 181 /- /- /106 /40 /119
BCDL: 7.00
Risk Category: 11
FT/RT:10(0)/10(10)
HORZ(LL): -0.005 B
C 76 /- /- /37 /-
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.007 C
B 133 /- /- /81 /114 /-
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
NCBCLL: 10.00
TCDL: 5.0 sf
p
Max TC CSI: 0.372
A Brg Width = 3.8 Min Req = 1.5
Load Duration: 1.25
BCDL: 4.2 psf
C Brg Width = 1.5 Min Req = -
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
Max BC CSI: 0.210
B Brg Width = 1.5 Min Req = -
C&C Dist a: 3.00 it
Max Web CSI: 0.000
Bearing A is a rigid surface.
Loc. from endwall: not in 4.50
Wgt: 15.4 lbs
Bearing A requires a seat plate.
GCpi: 0.18
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.16
Chords Tens.Comp.
Lumber
A - B 59 -111
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Maximum Bot Chord Forces Per Ply (Ibs)
Purlins
Chords Tens.Comp.
In lieu of structural panels
or rigid ceiling use puriins
A - C 0 0
to laterally brace chords as follows:
Chord Spacing(in
oc) Start(ft) End(ft)
BC 54
0.09 4.65
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pfanav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
(:nnvdnht [) 2016 A-1 Ronf Tni- e – Re—nduntinn of (hit domino—t. in anv form it nrnhihilnd vAihrnd 1ha vfit(nn nermissinn of A-1 Rnof Tmcsat
ARMSCM1560Bl L J5P
T
SEAT PLATE REQ.
�- - VY9 { 5'
JACK
2493
Loading Criteria (psi) Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/deft L/#
Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): NA
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): NA
B 299 /_ /_ /276 /114 /161
BCDL: 7.00 Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.004 D
D 77 !- /- /110 /58 A
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.008 D
C 127 /- A /81 /105 A
Des Ld: 37.00 Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
NCBCLL: 10.00 TCDL: 5.0 psi
Max TC CSI: 0.331
B Br Width = 8.0 Min Re 1.5
Load Duration: 1.25 BCDL: 4.2 psf
"
Max BC CSI: 0.279
9 q _ -
D Brg Width = 1.5 Min Req
Spacing: 24.0 MWFRS Parallel Dist: 0 to h/2
g
C Brg Width = 1.5 Min Req = -
C&C Dist a: 3.00 ft
Max Web CSI: 0.000
Bearing B is a rigid surface.
Loc. from endwall: not in 4.50
Wgt: 18.2 lbs
Bearing B requires a seat plate.
GCpi: 0.18
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.16 I
Chords Tens.Comp. Chords Tens. Comp.
Lumber
A - B 39 0 B - C 57 -118
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Maximum Bot Chord Forces Per Ply (lbs)
Purlins
Chords Tens.Comp.
In lieu of structural panels or rigid ceiling use purlins
B - D 0 0
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 58 0.15 5.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member
design.
Left bottom chord exposed to wind.
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized Ierms are as defined in TPI -i.
r; n.ht n 2016 A-1 Rnnf T.,..,-- Rnnrnnnnlinn of thiq nn—entin anv fnnn. is nn fiffi nn jithn t tht. wnHen nnnnicsinn of A-1 Rnnf Tnictac
Job Truss Truss Type Qty I Ply 07/13/2020
ARMSCM1560B1L J6 JACK 1 1 2539
9 �
ri
C
i- 1-5"9
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 25.00 It
NCBCLL: 10.00
TCDL 5.0 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 it
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 66 0.15 5.62
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
SEAT PLATE REQ.
Code / Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Wind
Wind loads based on MWFRS with additional C&C member design.
57"7 _ I
Defl/CSI Criteria
PP Deflection in loc L/deft L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.007 D
HORZ(TL): 0.012 D
Creep Factor: 2.0
Max TC CSI: 0.417
Max BC CSI: 0.281
Max Web CSI: 0.000
Wgt: 19.6 Ibs
VIEW Ver: 19.01.00A.0618.16
011
r Q
M
A Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw /U / RL
B 321 /- /- /226 /111 /177
D 88 /- / Al I-
C 146 /- /- /87 /122 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A -B 39 0 B -C 65 -118
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B -D 0 0
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineenn
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI.1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -I.
Cnnvdnht 02otfi A-1 Roof T.i .PG– Re r dimtion of this dmurnnnt in anv form, is ornhinirnd vAthnut ihe. viritinn nvnniss on of A-1 Roof T—nn
Job Truss
IARMSCM1560BlL J7
f
Truss Type
EJAC
Qty Ply 07/13/2020
9 1
C
SEAT PLATE REQ.
1'5"9 1 7t
2602
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
A Maximum Reactions (Ibs)
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/deft L/#
Gravity Non -Gravity
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
VERT(LL): NA
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): NA
B 371 /- /- /254 /122 /213
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.014 D
D 111 /- /- /54 /- /-
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.027 D
C 186 /- /- /112 /155 /-
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
NCBCLL: 10.00
TCDL: 5.0 sf
p
Max TC CSI: 0704
B Brg Width = 8.0 Min Req = 1.5
Load Duration: 1.25
BCDL: 4.2 psf
.
Max BC CSI: 0.449
D Brg Width = 1.5 Min Req = -
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C Brg Width = 1.5 Min Req = -
C&C Dist a: 3.00 ft
Max Web CSI: 0.000
Bearing B is a rigid surface.
Loc. from endwall: not in 4.50
Wgt: 23.8 lbs
Bearing B requires a seat plate.
GCpi: 0.18
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.16
Chords Tens.Comp. Chords Tens. Comp.
Lumber
A - B 39 0 B - C 83 -138
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Maximum Bot Chord Forces Per Ply (Ibs)
Purlins
Chords Tens.Comp.
In lieu of structural panels or rigid ceiling use purlins
B - D 0 0
to laterally brace chords as follows:
Chord Spacing(in
oc) Start(ft) End(ft)
BC 75
0.15 7.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
Cnn mht n 2n1 A-1 Rnnf Tnitcec - Rnnrndndinn of thia H.-mnnf in nnv fnnn. ix nrnhihit,d wifhnnf thn wdffnn -mi-inn of A-1 Rnnf Tru—
JobI russ
ARMSCM1560BlL J7C
4 L
Iruss lype
EJAC
Qry I rly
6 1
.7
SEAT PLATE REQ.
�--- 1'5"9 --- — 27"10 i 4'4"6 —=j
7'
U I/ 113/ZULU
3368
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
A Maximum Reactions (Ibs)
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.120 F 684 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.222 F 370 240
B 371 /- /- /254 1122 /213
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.050 G - -
E 107 /- /- /54 /1 /-
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.092 G
D 184 /- /- /112 /150 /-
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
NCBCLL: 10.00
TCDL: 5.0 psf
Max TC CSI: 0.669
B Brg Width = 8.0 Min Req = 1.5
Load Duration: 1.25
BCDL: 4.2 psf
E Erg Width = 1.5 Min Req = -
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
Max BC CSI: 0.418
D Erg Width = 1.5 Min Req = -
C&C Dist a: 3.00 ft
Max Web CSI: 0.206
Bearing B is a rigid surface.
Loc. from endwall: not in 9.00 f
Wgt: 28.0 lbs
Bearing B requires a seat plate.
GCpi: 0.18
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.16
Chords Tens.Comp. Chords Tens. Comp.
Lumber
A -B 39 0 C -D 82 -130
Top chord 2x4 SP #2
B - C 0 -213
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Maximum Bot Chord Forces Per Ply (Ibs)
Plating Notes
Chords Tens.Comp. Chords Tens, Comp.
All plates are 1.5X3 except as noted.
B - F 98 -107 G - E 0 0
C - G 106 -89
Purlins
In lieu of structural panels
or rigid ceiling use purlins
Maximum Web Farces Per Ply {Ibs)
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
Webs Tens.Comp.
BC 30
0.15 2.49
G - F 51 21
BC 66
2.49 7.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design
-WARNING"' Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 Sl. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless etherise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
C nvnnht 0 2016 A.1 Rnnf Tni- -e - Rnnmrinntien nr thix rfnnimnntin anv form. is omhihited without the wnttnn n..—i.-ien of A-1 Rnnf T.,-....,
Job Truss
ARMSCM1560B1L RP
Truss Type
EJAC
Qty Ply 07/13/2020
5 1
C
SEAT PLATE REQ.
E-- 1'5"9 1 7'
2496
Loading Criteria (psf) Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/deft L/#
Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): NA
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): NA
B 371 /- /- /343 /135 /213
BCDL: 7.00 Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.014 D
D 111 /- /- /161 /86 /-
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.027 D
C 186 /- /- /121 1152 /-
Des Ld: 37.00 Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
NCBCLL: 10.00 TCDL: 5.0 sf
p
Max TC CSI: 0704
B Brg Width = 8.0 Min Req = 1.5
Load Duration: 1.25 BCDL: 4.2 psf
.
Max BC CSI: 0.594
D Brg Width = 1.5 Min Req = -
Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2
C Brg Width = 1.5 Min Req = -
C&C Dist a: 3.00 ft
Max Web CSI: 0.000
Bearing B is a rigid surface.
Loc. from endwall: not in 4.50
Wgt: 23.8 lbs
Bearing B requires a seat plate.
GCpi: 0.18
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.16
Chords Tens.Comp. Chords Tens. Comp.
Lumber
A - B 39 0 B - C 83 154
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Maximum Bot Chord Forces Per Ply (Ibs)
Purlins
Chords Tens.Comp.
In lieu of structural panels or rigid ceiling use purlins
B - D 0 0
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.15 7.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member
design.
Left bottom chord exposed to wind.
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' fonn.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -I,
C—rinht n 2016 A-1 Rnnf Tnta – R.nrnd—Aran of thic dnr rn-1. in anv fnrm. i[ nrnhihifed withnid the wdden nermi-inn of A-1 Rnnf Tn,c
Job I russ I I rubs I We
ARMSCM1560BlL VM01 VAL
,,Qky I rly
1 1
1 5°i 313"9 + 2'0"1 _�
610"9
57"l X111
)E
u// I.]/Lulu
2584
Loading Criteria (psr)
Wind Criteria
Code / Mise Criteria
Defl/CSI Criteria
A Maximum Reactions (lbs), or *=PLF
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/deft L/#
Gravity Non -Gravity
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.070 B 987 360
Loc R+ / R- ! Rh / Rw /U / RL
E* 76 /- !- /40 /16 /10
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.133 B 519 240
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.027 B - -
Wind reactions based on MWFRS
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.052 B
E Big Width = 70.6 Min Req = -
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
Bearing A is id surface.
9 a rigid
NCBCLL: 10.00
TCDL: 5.0 psf
Max TC CSI: 0.379
Maximum Top Chord Forces Per Ply (lbs)
Load Duration: 1.25
BCDL: 4.2 psf
Max BC CSI: 0.357
Chords Tens.Comp. Chords Tens. Comp.
Spacing: 24.0 "
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Max Web CSI: 0.278
A - B 35 -109 B - C 54 -47
Loc. from endwall: not in 9.00
Wgt: 21.0 lbs
GCpi: 0.18
1 Maximum Bot Chord Forces Per Ply (Ibs)
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.16
Chords Tens.Comp.
Lumber
A - D 83 -2
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Maximum Web Forces Per Ply (Ibs)
Webs 2x4 SP #3
Webs Tens.Comp.
Purlins
C -D 195 -149
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 3.88 5.88
BC 71 0.00 5.88
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Additional Notes
See STD DETAILS for valley details.
—WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierre, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
Convrinht t7 201R A.1 Roof To--- Renrndiiolion of Ihm doon—t in anv In— is nrohibitod,01,nut 1he written nanni-lon of A-1 Roof Tnlsses
Job
ARMSCM1560BlL
Truss Truss Type
VM02 VAL
F 15 7'3"10
Qty Ply 07/13/2020
1 1
C
i 7'10"9 1
E- —510"4 Fi1V'13—�
117A
1
1
2581
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
DefI/CSI Criteria
♦ Maximum Reactions (lbs), or *=PLF
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/deft L/#
Gravity Non -Gravity
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
VERT(LL): -0.032 C
999 360
Loc R+ / R- / Rh / Rw /U / RL
F* 76 /- /- /46 /15 /17
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): -0.062 C
999 240
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): -0.023 C
- -
Wind reactions based on MWFRS
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.043 C
F Brg Width = 94.6 Min Req = -
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
Bearin A is a rigid surface.
9 9
NCBCLL: 10.00
TCDL: 5.0 psf
Max TC CSI: 0.365
Maximum Top Chord Forces Per Ply (Ibs)
Load Duration: 1.25
BCDL: 4.2 psf
Max BC GSI: 0.304
Chords Tens.Comp. Chords Tens. Comp.
Spacing: 24.0 "
MWFRS Parallel Dist: h/2 to h
A - B 71 -187 B - C 0 -48
C&C Dist a: 3.00 ft
Max Web CSI: 0.140
Loc. from endwall: not in 9.00
Wgt: 28.0 Ibs
GCpi: 0.18
Maximum Bot Chord Forces Per Ply (Ibs)
VIEW Ver: 19.01.00A.0618.16
Wind Duration: 1.60
Chords Tens.Comp. Chords Tens. Comp.
Lumber
A - E 224 -40 E - D 226 -44
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
Purlins
B - E 348 -285
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.00 7.88
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Right end vertical not exposed to wind pressure.
Additional Notes
See STD DETAILS for valley details.
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
C—nnht 0 2016 A-1 Rnnf Tni..,-- Rnnrndnntinn of thi., dnraimnnt in nnv fnnn. m nrnhihitnd withnni thn wntlnn nnnnisninn of A-1 Rnnf T nn
Job
ARMSCM1560B1 L
Truss Truss Type QtyPly 07/13/2020
VM03 VAL 1 11
9'3"10 - =j
r•
—era
9,10„9 1
�-
&10"4 `t- 4'0"5 --�
Loading Criteria (pst)
Wind Criteria
Code / Misc Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
BCDL: 7.00
Risk Category: it
FT/RT:10(0)/10(10)
EXP: B Kzt: NA
Plate Type(s):
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.00 9.88
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member
design.
Right end vertical not exposed to wind pressure.
Additional Notes
See STD DETAILS for valley details.
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.025 E 999 36(
VERT(CL): 0.048 E 999 24(
HORZ(LL): 0.007 E - -
HORZ(TL): 0.013 E
Creep Factor: 2.0
Max TC CSI: 0.409
Max BC CSI: 0.281
Max Web CSI: 0.092
2578
A Maximum Reactions (lbs), or'=PLF
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw /U / RL
F` 76 P /- /46 /16 /17
Wind reactions based on MWFRS
F Brg Width = 118 Min Req = -
Bearing A is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - B 76 -233 B - C 36 -77
Wgt: 40.6 Ibs
Maximum Bot Chord Forces Per Ply (Ibs)
VIEW Ver: 19.01.00A.0618.16 Chords Tens.Comp. Chords Tens. Comp.
A - E 258 -52 E - D 265 -56
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
B - E 310 -353 C - D 128 -80
**WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1.
(:nnvnnhf n 2f116 A-1 Rnnf Tnissr_s — RPnrndunlinn of this dnemm�nf in anv form. is nrnhihiled without fha wrihnn nnrtnixsinn nt A-1 Rnnf T........
Job Truss Truss Type
ARMSCM1560B1L VM04 VAL
-ea
Qty I Ply 07/13/2020
11'3"10
r
i 5'10"4 6'0"5 �{
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
EXP: B Kzt: NA
Plate Type(s):
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.00 11.88
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Right end vertical not exposed to wind pressure.
Additional Notes
See STD DETAILS for valley details.
Defl/CSI Criteria
PP Deflection in loc L/deft L/#
VERT(LL): 0.020 E 999 36(
VERT(CL): 0.039 E 999 24(
HORZ(LL): 0.005 E - -
HORZ(TL): 0.010 E
Creep Factor: 2.0
Max TC CSI: 0.614
Max BC CSI: 0.349
Max Web CSI: 0.105
1
2575
♦ Maximum Reactions (lbs), or *=PLF
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
F* 76 /- /- /47 /16 /17
Wind reactions based on MWFRS
F Brg Width = 142 Min Req = -
Bearing A is a rigid surface.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp. Chords Tens. Comp.
A - B 89 -284 B - C 64 -110
Wgt: 47.6 lbs
Maximum Bot Chord Forces Per Ply (Ibs)
VIEW Ver: 19.01.00A.0618.16 Chords Tens.Comp. Chords Tens. Comp.
A - E 296 -63 E - D 305 -68
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
B - E 353 -430 C - D 180 -144
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI -1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI -1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St, Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI -1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI -1.
(:onvnnht n 2016 AA Rnnf Tnt ev – Renrndnntinn of this room nt in aov fortem omhihnod without the written nenni-m of A-1 Roof Tojc .,
-4
Amm
Jwwmml� :
ANWOMMM
Omanw
A-1 ROOF TRUSSES
4.451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
TYPICAL HIP / KING JACK CONNECTION I STDTL01
MAX LOAD: 55 psf Roof Load, 175 mph, ASCE
7-10, Exp. B, C up to 60' Mean Roof Height
and Exposure D up to 30' Mean Roof Height.
Attach King Jack w/ (3) 16d Toe
,Nails @ TC & BC
Attach Corner Jack's
Attach End Jack's I
X w/ (2) 16d Toe Nails @ TC &
w/ (4) 16d Toe Nails @ TC < BC (Typ)
& (3) 16d Toe Nails @ BC
CD
-1
r1- cm
ttach Corner Jack's
(/ (2) 16d Toe Nails
@ TC & BC (Typ)
Rama Pranav Krislam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, Fl- 34946
I
FEBRUARY 17, 2017 ALTERNATE GABLE END BRACING DETAIL STDTL03
In
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD,
FORT PIERCE, FL 34946
7721409.10110
ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD
1'-3'MAX.
DIAG. BRACE
AT 1/3 POINTS
IF NEEDED
IT IS THE RESPONSIBILITY OF THE BLDG.
DESIGNER OR THE PROJECT ENGINEER/ARCHITECT
TO DESIGN THE CEILING DIAPHRAGM AND ITS
ATTACHMENT TO THE TRUSSES TO RESIST ALL
OUT OF PLANE LOADS THAT MAY RESULT FROM
THE BRACING OF THE GABLE ENDS.
HORIZONTAL BRACE
(SEE SECTION A -A)
TRUSSSES 0
24' O.C.
2X6 DIAGONAL BRACE SPACED 4B'
O.C. ATTACHED TO VERTICAL WITH
(4) - 16d NAILS, AND ATTACHED TO
BLOCKING WITH (5) - 10d COMMONS.
NAIL DIAGONAL BRACE TO
PURLIN WITH TWO 16d NAILS.
2X4 PURLIN FASTENED TO FOUR
TRUSSES WITH (2) - 16d NAILS
EACH. FASTEN PURLIN TO BLOCKING
W/ (2) - 16d NAILS (MIN.).
' PROVIDE 2X4 BLOCKING BETWEEN
THE TRUSSES SUPPORTING THE
\BRACE AND THE TWO TRUSSES ON
\EITHER SIDE AS NOTED. TOENAIL
\ BLOCKING TO TRUSSES WITH (2) -
10d NAILS AT EACH END. ATTACH
DIAGONAL BRACE TO BLOCKING WITH
(5) - 10d COMMON WIRE NAILS.
END WALL
CEILING SHEATHING
BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES
STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED:
METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE
OF THE STRUCTURAL GABLE AND FASTEN PER THE
FOLLOWING NAIL SCHEDULE.
METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL
MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING
NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG
SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. VERTICAL
NAILING SCHEDULE:
- FOR WIND SPEEDS 120 MPH (ASCE 7-9B, 02, 05), 150 MPH (ASCE
7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (.131'
X 3') NAILS SPACED 6' O.C.
- FOR WIND SPEEDS GREATER 120 MPH (ASCE 7-98, 02, 05), 150
MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d
(.131'X3') NAILS SPACED 6' O.C. (2X4 STUDS MINIMUM).
STRUCTURAL
GABLE TRUSS
MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALI
BRACING METHODS SHOWN ON PAGE 1 ARE VALID
AND ARE TO BE FASTENED TO THE SCABS OR
VERTICAL STUDS OF THE STANDARD GABLE TRUSS
ON THE INTERIOR SIDE OF THE STRUCTURE.
NOTE: THIS DETAIL IS TO BE USED ONLY FOR
STRUCTURAL GABLES WITH INLAYED /
STUDS. TRUSSES WITHOUT INLAYED
\S ARE NOT ADDRESSED HERE. /
STANDARD GABLE /
TRUSS
URAL
TRUSS
:Tttn
AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING
MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF
THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS,
THE BRACING SHOWN IN THIS DETAIL IS FOR
VERTICAL/STUDS ONLY.
Rama Pranav Kdstam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
i
12/23/19 PIGGY- BACK TRUSS STDTL04.1
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD,
FORT PIERCE, FL 34946
772-409-9010
PIGGY -BACK DETAIL (TYPICAL)
180 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG.
LOCATED ANYWHERE AT ROOF, EXPOSURE C, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00.
OR...
160 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG.
LOCATED ANYWHERE AT ROOF, EXPOSURE D, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00.
IMPORTANT NOTE:
TOP CHORDS OF TRUSSES SUPPORTING PIGGY -BACK CAP TRUSSES MUST BE ADEQUATELY
BRACED BY SHEATHING AND/ OR PURLINS. THE BUILDING ENGINEER OF RECORD SHALL
PROVIDE DIAGONAL BRACING OR OTHER SUITABLE ANCHORAGE TO PERMANENTLY
RESTRAIN PURLINS AND LATERAL BRACING FOR OUT OF PLANE LOADS OVER GABLE ENDS.
MAXIMUM TRUSS SPACING IS NOT TO EXCEED 24" O.C.
DETAIL IS NOT APPLICABLE IF CAP SUPPORTS ADDITIONAL LOADS SUCH AS CUPOLA,
STEEPLE, CHIMNEY OR DRAG STRUT LOADS.
**REFER TO ENGINEER'S SEALED TRUSS DESIGN DRAWINGS FOR PIGGY -BACK AND BASE
TRUSS SPECIFICATIONS.**
PIGGY -BACK TRUSS. (REFER
TO ACTUAL TRUSS DESIGN
DRAWINGS FOR ADDITIONAL
INFORMATION.)
2'-0"
MAX
OPTION NO. 1 - TEE-LOK
3" x 8" TEE-LOK MULTI -USE CONNECTION PLATES SPACED
AT 4'-0" O.C. MAX. PLATES SHALL BE PRESSED INTO
PIGGY -BACK TRUSS AT 4'-0" O.C. STAGGERED FROM
EACH FACE AND NAILED TO BASE TRUSS WITH 4 EACH
6d (1.5" X 0.099") NAILS IN EACH PLATE TO ACHEIVE
MAXIMUM UPLIFT CAPACITY OF 377 LBS AT EACH 3" X 8"
TEE-LOK MULTI -USE CONNECTION PLATE (MINIMUM OF 2
PLATES).
OPTION NO.2 - APA RATED GUSSET:
8" x 8" x 0-7/16" (MIN.) APA RATED SHEATHING GUSSETS
EACH FACE. ATTACH AT 8'-0" O.C. w/ 8 (EACH) 6d
COMMON (0.1 13" x 2") NAILS PER GUSSET: 4 (EACH) AT
CAP BOTTOM CHORD & 4 (EACH) AT BASE TRUSS TOP
CHORD. GUSSETS MAY BE STAGGERED AT 4'-0" O.C.
FRONT TO BACK FACES. MINIMUM TWO (2 EA.)
CONNECTIONS AT EACH TRUSS.
OPTION NO. 3 - 2X4 VERTICAL MOOD SCAB:
2X4 SPF #2, FULL CHORD DEPTH SCABS AT EACH FACE.
ATTACH AT 8'-0" O.C. w/6 (EACH) l Old BOX NAILS (0.128"
x 3") PER SCAB: 3 (EACH) AT CAP BOTTOM CHORD AND
3 (EACH) AT BASE TRUSS TOP CHORD. SCABS MAY BE
STAGGERED 4'-0" O.C. FRONT TO BACK FACES.
MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS.
OPTION #1: TEE-LOK MULTI -USE
CONNECTION PLATE.
OPTION #2: APA RATED GUSSET.
OPTION #3: 2X4 VERT. SCAB,
ATTACH EACH PURLIN TO TOP
CHORD OF BASE TRUSS. PURLIN
& CONNECTIONS BY OTHERS.
BASE TRUSS. (REFER TO TRUSS
DESIGN DRAWINGS FOR
ADDITIONAL INFORMATION.)
PURLINS SPACED ACCORDING
TO MAX. SPACING OF TOP
CHORD OF BASE TRUSS.
SPACING IS NOT TO EXCEED 24"
O.C. & PURLINS TO BE LOCATED
AT JOINT OF EACH BASE TRUSS.
** IMPORTANT NOTE **
THIS DETAIL IS VALID ONLY FOR SINGLE PLY BASE TRUSSES
SPACED AT 24" O.C. OR LESS.
Rama Pranav Krislam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
JUILY 17, 2017 1 TRUSSED VALLEY SET DETAIL - SHEATHED I STDTL05
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772409-1010
VALLEY TRUSS
(TYPICAL)
SECURE VALLEY TRUSS
W/ ONE ROW OF 10d
NAILS 6" O.C.
GENERAL SPECIFICATIONS:
1. NAIL SIZE = 3" X 0.131" = 10d
2. WOOD SCREW = 4.5' SDS25412 SIMPSON OR
EQUIVALENT.
3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES.
4. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND
SECURE TO BASE TRUSSES AS PER DETAIL "A".
5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE
INDIVIDUAL DESIGN DRAWINGS.
6. NAILING DONE PER NDS - 01.
GABLE END, COMMON 7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C.
TRUSS, OR GIRDER
TRUSS
BASE TRUSSES
-C CIVu, UUIvw UIV
3S, OR GIRDER TRUSS
TRUSS CRITERIA:
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05:146 MPH
WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12
CATERGORY II BUILDING
EXPOSURE C
WIND DURATION OF LOAD INCREASE: 1.60
MAX TOP CHORD TOTAL LOAD = 50 PSF
ATTACH 2X4 CONTINUOUS #2 MAX SPACING = 24" O.C. (BASE AND VALLEY)
SYP TO THE ROOF W/ TWO MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
SIMPSON SDS25412 (1/4" X 4.5')
OR EQUIVALENT WOOD SCREWS
INTO EACH BASE TRUSS.
Rama Pranav Kristam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
vwffllwllrl-1 : i•
SECURE
W/(
VALLEY TRUSS
(TYPICAL) —v I) 11'71,
11 1� II II II BASE Tii SSES
II 11
1
V L 1 1"11 L M
(NO SHEATHING) N.T.S.
GABLE END, COMMON
TRUSS, OR GIRDER
VALLEY TRUSS TRUSS
P 12 (TYPICAL)
SEE DETAIL "A"
BELOW (TYP.)
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05:146 MPH
GENERAL SPECIFICATIONS:
WIND DESIGN PER ASCE 7-10: 170 MPH
1. NAIL SIZE= 3" X 0.131" = 10d
Mosm
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12
2. WOOD SCREW = 3" SDS25300 SIMPSON OR EQUIVALENT.
amom
3. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE PER DETAIL
WIND DURATION OF LOAD INCREASE: 1.60
„A„
MAX TOP CHORD TOTAL LOAD = 50 PSF
SYP TO THE ROOF W/ TWO
4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN
SIMPSON SDS25300 (1/4" X 3")
MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
DRAWINGS.
A96#m""
SCREWS INTO EACH BASE
5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT
TRUSS.
TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING.
A-1 ROOF TRUSSES
6. NAILING DONE PER NDS - 01.
4451 ST. LUCIE BLVD.
GABLE END, COMMON
7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C.
FORT PIERCE, FL 34946
TRUSS, OR GIRDER
772-409-1010
TRUSS
SECURE
W/(
VALLEY TRUSS
(TYPICAL) —v I) 11'71,
11 1� II II II BASE Tii SSES
II 11
1
V L 1 1"11 L M
(NO SHEATHING) N.T.S.
GABLE END, COMMON
TRUSS, OR GIRDER
VALLEY TRUSS TRUSS
P 12 (TYPICAL)
SEE DETAIL "A"
BELOW (TYP.)
Rama Pranav Kristen P.E.
# 88906
4451 St. Lucie Blvd. Suite 201
Fort Pierce, FL 34946
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05:146 MPH
WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12
CATERGORY II BUILDING
EXPOSURE C
WIND DURATION OF LOAD INCREASE: 1.60
ATTACH 2X4 CONTINUOUS #2
MAX TOP CHORD TOTAL LOAD = 50 PSF
SYP TO THE ROOF W/ TWO
MAX SPACING = 24" O.C. (BASE AND VALLEY)
SIMPSON SDS25300 (1/4" X 3")
MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
OR EQUIVALENT WOOD
SCREWS INTO EACH BASE
TRUSS.
Rama Pranav Kristen P.E.
# 88906
4451 St. Lucie Blvd. Suite 201
Fort Pierce, FL 34946
JULY 17, 2017
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD,
FORT PIERCE, FL 34946
772-409-1010
ATTA(
WIND DESIGN PER ASCE 7-98, ASCE 7-1
WIND DESIGN PER ASCE 7-10: 170 MPI
MAX MEAN ROOF HEIGHT = 30 FEET
CATERGORY II BUILDING
EXPOSURE B OR C
WIND DURATION OF LOAD INCREASE:
MAX TOP CHORD TOTAL LOAD = 50 PSI
MAX SPACING = 24" O.C. (BASE AND VA
SUPPORTING TRUSSES DIRECTLY UNG— —1— � . —.... I—. I —
DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2'- 10" ON AFFECTED
TOP CHORDS.
(HIGH WIND VELOCITY) - I STDTL07
NOTES:
1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES.
2. THIS DETAIL IS NOT APPLICABLE FOR SPF -S SPECIES LUMBER.
FOR BEVELED BOTTOM
CHORD, CLIP MAY BE APPLIED
TO EITHER FACE.
NON -BEVELED
BOTTOM CHORD
CLIP MAY BE APPLIED
TO THIS FACE UP TO A
MAXIMUM 6/12 PITCH
CLIP MUST BE APPLIE
THIS FACE WHEN I
EXCEEDS 6/12 (MAX
12/12 P
Rama Pranav Kristam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
FEBRUARY 17, 2017 ( STANDARD GABLE END DETAIL 1 STDTL08
A-1 ROOF TRUSSES
4451 ST, LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
TYPICAL 2X4 L -BRACE
NAILED TO 2X4 VERTICALS
W/lOd NAILS, 6' O.C.
VERI
STUD
SECTION B -B
TRUSS GEOMETRY AND CONDITIONS
SHOWN ARE FOR ILLUSTRATION ONLY.
DIAGONAL
BRACE 4' - 0' D.C. MAX.
SEE INDIVIDUAL ENGINEERING DRAWINGS
FOR TRUSS DESIGN CRITERIA.
12
Q VARIES TO COMMON TRUSS
3X4 =
v
DIAGONAL BRACING L - BRACING REFER
REFER TO SECTION A -A TO SECTION B -B 24' MAX.
NOTE:
1. MINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM CHORDS.
2. CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS AND WALL TO
BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT.
3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT SLOG.
ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF
SYSTEM.
4. 'L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR
BETTER WITH ONE ROW OF 10d NAILS SPACED 6' O.C.
5. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM
AT 4'-0'D.C.
S. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN
WITH 16d NAILS SPACED 6' O.C. HORIZONTAL BRACE TO BE LOCATED AT
THE MIDSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE
STUDS WITH (3) 10d NAILS THROUGH 2X4 (REFER TO SECTION A -A)
GA LE STUD DEFLECTION MEETS OR EXCEEEDS L/240
VERTICAL
2X6 SP OR SPF
STUD
#2 DIAGONAL
(2) DIAGONAL
BRACES AT
1/3 POINTS
BRACE
(4) - 16d
3-8-10
NAILS
16d NAILS
11-1-13
SPACED G' O.C.
(2) lOd NAILS
3.3.10
INTO 2X6
2X6 SP OR
9-10.15
SPF #2
2X4 SP OR
2.8-6
SPF #2
TYPICAL HORIZONTAL
8-1-2
BRACE NAILED TO
12" O.C.
2X4 VERTICALS
SECTION A -A
W/(4) - 10d NAILS
PROVIDE 2X4 BLOCKING BETWEEN
THE FIRST TWO TRUSSES AS NOTED.
TOENAIL BLOCKING TO TRUSSES
WITH (2) - 10d NAILS AT EACH END.
ATTACH DIAGONAL BRACE TO
BLOCKING WITH (5) - 10d NAILS
(4) Bd NAILS MINIMUM,
PLYWOOD SHEATHING TO
2X4 STD SPF BLOCK
12' MAX.
T"
1. B DIAG. BRACE
B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. AT 1/3 POINTS
9. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE IF NEEDED
TRUSSES.
10. 10d AND 16d NAILS ARE 0.131'X3.0' AND 0.131'X3.5' COMMON WIRE NAILS
RESPECTIVELY.
11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12
BY SPIB/ALSC.
MINIMUM STUD
SIZE SPECIES
AND GRADE
STUD
SPACING
WITHOUT
BRACE
2X4 DIAGONAL
L - BRACE BRACE
MAXIMUM STUD LENGTH
(2) DIAGONAL
BRACES AT
1/3 POINTS
2X4SP#31STUD
12" O.C*
3-8-10
5-6-11
6.6-11
11-1-13
2X4 SP #3 /STUD
1 16" O.C.
3.3.10
4-9-12
6-6.11
9-10.15
2X4 SP 43 / STUD
24" O.C.
2.8-6
3.11-3
5.4-12
8-1-2
2X4 SP #2
12" O.C.
3.10-15
5.6-11
6.6-11
11.8-14
2X4 SP #2
16" O.C.
3.6.11
4.9-12
6-6-11
10-8-0
2X4 SP#2
24" O.C.
3.1-4
3.11-3
6-2-9
9.3-13
DIAGONAL BRACES OVER 6' - 3' REQUIRE A 2X4 T -BRACE ATTACHED TO ONE
EDGE. DIAGONAL BRACES OVER 12' - 6' REQUIRE 2X4 I -BRACES ATTACHED TO
BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE
WITH 10d NAILS 6. O.C., WITH 3' MINIMUM END DISTANCE. BRACE MUST COVER
90% OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2.
MAX MEAN ROOF HEIGHT = 30 FEET
EXPOSURE B OR C
ASCE 7-10 190 MPH STUD DESIGN IS BASED ON COMPONENTS AND CLADDING.
DURATION OF LOAD INCREASE :1.60 CONNECTION OF BRACING IS BASED ON MWFRS.
ROOF
SHEATHING
(2) - 10d
NAILS
TRUSSES @ 24' O.C.
2X6 DIAGONAL BRACE
SPACED 48' D.C. ATTACHED
TO VERTICAL WITH (4) -
16d NAILS, AND ATTACHED
TO BLOCKING WITH (5) -
10d NAILS.
HORIZONTAL BRACE
(SEE SECTION A -A)
END WALL
Rama Pranav Krislam, P.E.
# 88906
4451 St. Lucia Blvd, Suite 201
Fort Pierce, FL 34946
1
FEBRUARY 17, 2017
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
a
WITH 2X BRACE ONLY
NOTES:
T -BRACING / I -BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING
IS IMPRACTICAL. T -BRACE / I -BRACE MUST COVER 90% OF WEB LENGTH.
THIS DETAIL NOT TO BE USED TO CONVERT T -BRACE / I -BRACE WEBS TO
CONTINUOUS LATERAL BRACED WEBS.
NAILING PATTERN
T -BRACE SIZE
NAIL SIZE
NAIL SPACING
2X4 OR 2X6 OR 2XB
1Od
6" O.C.
NOTE: NAIL ALONG ENTIRE LENGTH OF T -BRACE / I -BRACE (ON
TWO-PLY TRUSSES NAIL TO BOTH PLIES)
NAILS
BRACE
SIZE FOR ONE -PLY
TRUSS
SPECIFIED CONTINUOUS ROWS OF
LATERAL BRACING
WEB SIZE
1
2
2X3 OR 2X4
2X4 T -BRACE
2X4 I -BRACE
2X6
2X6 T -BRACE
2X6 I -BRACE
2XB
2X8 T -BRACE
2X8 I -BRACE
BRACE
SIZE FOR TWO-PLY
TRUSS
SPECIFIED CONTINUOUS ROWS OF
LATERAL BRACING
WEB SIZE
1
2
2X3 OR 2X4
2X4 T -BRACE
2X4 I -BRACE
2X6
2X6 T -BRACE
2X6 I -BRACE
2X8
2X8 T -BRACE
2X8 I -BRACE
T -BRACE / I -BRACE MUST BE SAME SPECIES
AND GRADE (OR BETTER) AS WEB MEMBER.
NAILS
WEB
NAILS
i .011 -Alm
1( NAILS
WEB
SECTION D E T A I L S_ma Pranav Kdstam, P.E.
#t 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS,
2XG "STRONGBACK' IS RECOMMENDED, LOCATED EVERY B TO 10 FEET
ALONG A FLOOR TRUSS.
NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE
_....... __...., TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY
A-1 ROOF TRUSSES OF THE METHODS ILLUSTRATED BELOW.
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34948 NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE
772-409-1010 BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS
FROM END TO END, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY
CONNECTED, BY OTHERS, AT THE ENDS.
INSERT WOOD SCREW THROUGH
OUTSIDE FACE OF CHORD INTO
EDGE OF STRONGBACK (DO NOT
USE METAL FRAMING ATTACH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS)
ANCHOR TO ATTACH WEB WITH (3) - 10d SCAB WITH (3) - 10d
TO TOP CHORD NAILS (0.131' X 3') NAILS (0.131' X 3'). ATTACH TO VERTICAL
WITH (N IBLS (0.1313)X 3')
BLOCKING BEHIND THE VERTICAL
WEB IS RECOMMENDED WHILE
NAILING THE STRONGBACK
USE METAL FRAMING -J L ATTACH TO VERTICAL
ANCHOR TO ATTACH WEB WITH (3) - 10d
TO BOTTOM CHORD NAILS (0.131' X 3')
ATTACH 2X4 VERTICAL
TO FACE OF TRUSS.
FASTEN TO TDP AND
BOTTOM CHORD WITH
(2) - lOd NAILS (0.131'
X 3') IN EACH CHORD
ATTACH TO VERTICAL
SCAB WITH (3) - 10d
NAILS (0.131' X 3')
TRUSS 2X6 r 4' -(TYPICAL SPLICE) WALL
STRONGBACK (BY OTHERS)
ATTACH TO CHORD
WITH (2) #12 X 3'
WOOD SCREWS
(0.216' DIA.)
INSERT SCREW THROUGH
OUTSIDE FACE OF CHORD INTO
EDGE OF STRONGBACK (DO NOT
USE DRYWALL TYPE SCREWS)
THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT,
DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - 0' LONG SCAB
CENTERED ON THE SPLICE AND JOINED WITH (12) - 10d NAILS (0.131' X 3')
EQUALLY SPACED.
ALTERNATE METHOD OF SPLICING:
OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) -
10d NAILS (0.131' X 3') STAGGERED AND EQUALLY SPACED (TO BE USED ONLY
WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL).
BLOCKING
(BY OTHERS)
Rama Pranav Kristam, P.E.
488906
4451 St. Lucie Blvd, Suite 201
I
FEBRUARY 17, 2017 LATERAL TOE -NAIL DETAIL
NOTES:
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45° WITH THE MEMBER
AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN
THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS
SHOWN).
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL
...................... BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
A-1 ROOF TRUSSES 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO
4451 ST. LUCIE BLVD. SPECIES FOR MEMBERS OF DIFFERENT SPECIES.
FORT PIERCE, FL 34946
772A09-1010
TOE -NAIL SINGLE SHEAR VALUES
PER NOS 2001 (LB/NAIL)
DIA
SP
OF
HF
SPF
SPF -S
.131
88.0
80.6
69.9
68.4
59.7
o
.135
93.5
85.6
74.2
72.6
63.4
J
in
.162
108.8
99.6
86.4
84.5
73.8
.128
74.2
67.9
58.9
57.6
50.3
.131
75.9
69.5
60.3
59.0
51.1
p
J
N
.148
81.4
74.5
64.6
63.2
52.5
ri
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
EXAMPLE:
(3) - 16d NAILS (0.162' DIA. X 3.5') WITH SPF SPECIES BOTTOM CHORD
FOR LOAD DURATION INCREASE OF 1.15:
3 (NAILS) X 84.5 (LB/NAIL) X 1.15 (DOL) = 291.5 LB MAXIMUM CAPACITY
ANGLE MAY
VARY FROM
30' TO 60°
45.00°
ANGLE MAY
VARY FROM
30° TO 60°
STDTL11
THIS DETAIL IS ONLY APPLICABLE TO
THE THREE END DETAILS SHOWN BELOW.
VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY.
SIDE VIEW
(2X3) 2 NAILS
-i NEAR SIDE
NEAR SIDE
SIDE VIEW
(2X4) 3 NAILS
NEAR SIDE
--I NEAR SIDE
NEAR SIDE
45.00°
SIDE VIEW
(2X3) 2 NAILS
NEAR SIDE
NEAR SIDE
NEAR SIDE
NEAR SIDE
ANGLE MAY
VARY FROM
3D° TO 60°
45.00°
P.E.
# 88906
4451 St, Lucie Blvd, Suite 201
Fort Pierce, FL 34946
FEBRUARY 17, 2017 1 UPLIFT TOE -NAIL DETAIL 1 STDTL12
A-1 ROOF TRUSSES
4451 ST, LUCIE BLVD.
FORT PIERCE, FL 34946
772409-1010
THIS DETAIL SHALL BE USED FOR A CONNECTION
RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER
IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS.
TOE -NAIL WITHDRAWAL VALUES
PER NOS 2005 (LB/NAIL)
DIA.
SP
OF
HF
SPF
SPF -S
LD
.131
59
46
32
30
20
z
O
J
.135
60
48
33
30
20
a
162
72
58
39
37
25
J
7::
CD
.128
54
42
28
27
19
F—
z
LD
z
O
J
.131
55
43
29
28
19
W
.148
62
48
34
31
21
—I
"L0
J
N
Q
�
Z
.120
51
39
27
26
17
O
z
.128
49
38
26
25
17
O
.131
51
39
27
26
17
J
O
.148
57
44
31
28
20
N}
NOTES:
1. TOE—NAILS SHALL BE DRIVEN AT AN ANGLE OF 30° WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE
MEMBER END AS SHOWN.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION.
VALUES SHOWN ARE CAPACITY PER TOE—NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
EXAMPLE:
(3) — 16d NAILS (0.162° DIA. X 3.5`) WITH SPF SPECIES TOP PLATE
FOR WIND DOL OF 1.33:
3 (NAILS) X 37 (LB/NAIL) X 1.33 (DOL FOR WIND) = 14B LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND
FOR WIND DOL OF 1.60:
3 (NAILS) X 37 (LB/NAIL) X 1.60 (DOL FOR WIND) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND
IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LBS (177 LBS) BUILDING
DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION.
#00 USE (3) TOE—NAILS ON 2X4 BEARING WALL
*00 USE (4) TOE—NAILS ON 2X6 BEARING WALL
NEAR SIDE
FAR 5'.
ID
TOP PLATE
OF WALL
VIEWS SHOWN ARE FOR
ILLUSTRATION PURPOSES ONLY
IL
NAIL
NAIL
Rama Pranav Kristam, P.E.
SIDE VIEW END VIEW #x8966
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
rE6ROARY 5, 2016
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
TYP W NAILER ATTACHMENT I STDTL13
2x2 NAILER ATTACHMENT
GENERAL SPECIFICATIONS
MAX LOAD: 55 psf Roof Load, 170 mph, ASCE
7-10, 29'-0" Mean Height, Exp. B, C or D.
lffik �
Rama Pranav Kristam, P.E.
488906
4451 St. Lucie Blvd, Suite 201
April 11, 2016TYPICAL ALTERNATE BRACING DETAIL STDTL14
I FO EXTERIOR FLAT GIRDER TRUSS I
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVO
FORT PIERCE, FL 34946
772-409-1010
aml
12
VARIES
MAX 3011(21-611)
2x6 #2 SP (Both Faces)
24" O.C.
SIMPSON H5
Rama Pranav Kristam, P.E.
# 88906
4451 St. Lucie Blvd. Suite 201
Fort Pierce, FL 34946
�FEBRUARY 17, 2017 I STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND I STDTL15
DAMAGED OR MISSING CHORD SPLICE PLATES
A1 ROOF TRUSSES
4451 ST, LUCIE BLVD,
FORT PIERCE, FL 34946
772-409.1010
TOTAL NUMBER
OF NAILS EACH
SIDE OF BREAK *
X
(INCHES)
MAXIMUM FORCE (LBS) 157 LOAD DURATION
SP
OF
SPF
HF
2X4
2X6
2X4
2X6
2X4
2X6
2X4
2X6
2X4
2X6
20
30
24"
1706
2559
1561
2342
1320
1980
1352
2028
26
39
30"
2194
3291
2007
3011
1697
2546
1738
2608
32
48
36"
2681
4022
2454
3681
2074
3111
2125
31B7
38
57
42"
3169
4754
2900
4350
2451
3677
2511
3767
44
fib
4B"
3657
5485
3346
5019
2829
4243
2898
4347
DIVIDE EQUALLY FRONT AND BACK
ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF
THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X41 THREE
ROWS FOR 2X6) SPACED 4' D.C. AS SHOWN (.131' DIA. X 3').
STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' O.C. SPACING IN
THE MAIN MEMBER. USE A MIN. 3' MEMBER END DISTANCE.
THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS)
THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X + C
""" , I - � - I-' �;." �--' � �.
• 10d NAILS NEARSIDE
+ 10d NAILS FAR SIDE
V\1\4
TRUSS CONFIGURATION
AND BREAK LOCATIONS
FOR ILLUSTRATIONS ONLY
THE LOCATION OF THE BREAK MUST BE GREATER THAN OR EQUAL TO
THE REQUIRED X DIMENSION FROM ANY PERIMETER BREAK OR HEEL JOINT
AND A MINIMUM OF 6' FROM ANY INTERIOR JOINT (SEE SKETCH ABOVE).
DO NOT USE REPAIR FOR JOINT SPLICES
NOTES:
1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR
DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE
TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN
THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF
SUPPORTING THE LOADS INDICATED.
2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR
AND HELD IN PLACE DURING APPLICATION OF REPAIR.
3. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID
UNUSUAL SPLITTING OF THE WOOD.
4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID
LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. Rama Pranav Kdstam, P.E.
S. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2Xo ORIENTATION ONLY. #88906
6. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS. 4451 St. Lucie Blvd, Suite 201
FEBRUARY 17, 2017 1 SCAB APPLIED OVERHANGS I STDTL16
A-1 ROOF TRUSSES
4451 ST, LUCIE BLVD.
FORT PIERCE, FL 94948
772-A09-1090
TRUSS CRITERIA:
LOADING: 40-10-0-10
DURATION FACTOR: 1.15
SPACING: 24' O.C.
TOP CHORD: 2X4 OR 2X6
PITCH: 4/12 - 12/12
HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL
END BEARING CONDITION
NOTES:
1. ATTACH 2X -SCAB (MINIMUM #2 GRADE SPF, HF, SP, DF) TO ONE FACE OF TRUSS
WITH TWO ROWS OF 10d COMMON WIRE NAILS (.148' DIA. X 3') SPACED 6' O.C.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH
AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO
AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES.
2X SC
NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED
WHEN OVERHANG HAS BEEN BROKEN OFF.
THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 40') SPACED 24'
D.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TDP CHORD
LOADS NOT EXCEEDING 50 PSF.
TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY.
REFER TO INDIVIDUAL TRUSS DESIGN
FOR PLATE SIZES AND LUMBER GRADES
Rama Pranav Krislam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 201