HomeMy WebLinkAboutConstruction PlansSTRUCTURE CRITERIA DESIGN: *THIS OVERALL DESIGN COMPLIES WITH THE GUIDELINES DEFINED IN CHAPTERS 16 AND 20 OF THE 2017 FLORIDA BUILDING CODE 6TH EDITION, BUILDING AND ALL OTHER APPLICABLE STANDARDS WIND CRITERIA: *VELOCITY: 150 MPH (3 SECOND GUST), EXPOSURE 'C', RISK CATEGORY I. FOR VELOCITY >100 MILES PER HOUR, IMPORTANCE FACTOR SHALL = 0.77. SCREEN DESIGN: *18 X 14 SCREEN WALLS: WW PRESSURE @ 19.6 PSF, LW PRESSURE @ 15.6 PSF, ROOF @ 5.4 PSF DESIGN PRESSURE ON BUILDING ENVELOPE ELEMENTS: *PER THE ALLOWABLE STRESS DESIGN FOUND ON TABLE 2002.4 AND 2002.4A OF THE FLORIDA BUILDING CODE. *THE AVERAGE SPACING BETWEEN BEAMS IS SHOWN IN THE DRAWING. THE ACTUAL SPACING BETWEEN ANY TWO BEAMS MUST BE THE AVERAGE SPACING, +/_ 2", AND THE CENTER TO CENTER MUST NEVER BE GREATER THAN 8'-0". *EXTERIOR GLAZED OPENINGS SHALL BE PROTECTED BY PRODUCTS WHICH MEET THE REQUIREMENTS OF SSTD 12. SCREEN ENCLOSURE ROOF TYPE *GABLE ROOF ENCLOSURE WITH 3'0" RISE MAX, STRUCTURE IS CONNECTED TO EXISTING SINGLE STORY C.B.S. HOME WITH -WOOD FASCIA. (SEE CONNECTION DETAIL 4 ON PAGE 3). VVII VIU, IL7 *THIS ENCLOSURE WILL BE CONSTRUCTED ON A NEW PAVER PATIO, WITH AN 8"" X 8"" CONCRETE FOOTER WITH 1 #5 BAR CONTINUOUS. THIS FOUNDATION IS ACCEPTABLE FOR THIS ENCLOSURE. *ALL HOLD DOWN FASTENERS MUST BE NO MORE THAN 12" ON CENTER W/2-1/4"' MIN. EMBEDMENT INTO CONCRETE. ALUMINUM NOTES: MATERIALS SHALL CONFORM TO THE F.B.C., CHANGES SHALL BE DESIGNATED BY THE ENGINEER OF RECORD: 1: ALL EXTRUSIONS: ALUMINUM ALLOY #6005-T5 OR 6061-T6, (NOTE: SPLICE PLATE MATERIAL MAY BE EXTRUDED FROM ALUMINUM ALLOY 6061-T6, IF THIS ALLOY IS MORE READILY AVAILABLE). 2: FASTENERS: ALUMINUM ALLOY # 2024-T4 & #7075-T6 DOUBLE CAD -PLATED STEEL, HOT DIPPED GALVANIZED STEEL OR 300-SERIES STAINLESS STEEL 3: MATERIAL UPGRADES (STRONGER OR HIGHER GRADE MATERIALS) CAN BE SUBSTITUTED AT ANY TIME. 4: NO EXPANSION BOLT MAY BE INSTALLED WITHIN 2" OF EDGE OF CONCRETE SLAB. 5: NON STRUCTURAL ALUMINUM SHALL HAVE A MINIMUM THICKNESS NO LESS THAN 0.032" (KICKPLATES ETC.) 6: ALUMINUM IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PROTECTED WITH ALKALI RESISTANT COATING. 7: ALUMINUM IN CONTACT WITH WOOD SHALL BE PAINTED WITH TWO COATS OF HEAVY BODIED BITUMINOUS PAINT. 8: SELF MATING BEAMS (SMB) UP TO 8" TO BE FASTENED WITH BEAM STITCH SCREWS @ 16" 0/C BOTH SIDES. (#12 SMS), FOR 9" & 10" SELF MATING BEAMS (SMB) TO BE FASTENED WITH BEAM STITCH SCREWS @ 12" 0/C. FILE COPY VE V I ZE WOOE8D FOO BODE COMPLIANCE ST. L C9E COUNTY W socc �?JAQO Z� �:D w O way UQ zwz � WUco Zco H H w ��� coo a; �00 �M o w C"+ aH.S rn L` U>WW WN UUF.�aUZ V' Q WW accnW 04 °'aaw ad. m ti co i ti ti i N N w w r- i 00 C=) NR"C�1 ti ti 0 a a Ong wl SHEET NWER 1 OF 6 PLAN VIEW CONCRETE SPECIFICATION NOTES AND DESIGN . PA%ETERS 1)— 6" X 6" 10/10 WWM OR FIBERMESH ADDED CONCRETE. 2)— TERMITE TREATED SOIL WHEN NEXT TO LIVING SPACE. 3)— FOOTER SHALL BE 8" X 8" CONTINUOUS WITH ONE (1) #5 REBAR.. m� z FOQTER DETAIL 8" CONCROTr iTER AROUND IMETER Witt 1145 CONTINUO 'ER THE Pad' ERS 3000 1, CONOTE FI LLE 1- #5 BAI CONTI N 0,US REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY s+OCC 0 H W a Qwcli Lo C� W WxZM F-+ w W wAw pvLo+rr� U 00 a.; co co N U > W N iZiU�rWti�.. UUE- 0 - -.1u HWU wcccna�a a d cx. 00 dLs�6�Od..a N N = m C: M � w O � � W � CnaLo v 00 t—cli N l- O a SHEET NUMBER 2OF6 a:ILAN VIEW W �D tW �D U` + m O ill a x Hall DJ P3 N c) c/) I o W H d) C° P4 N 6'-0" 12'-0" 2 ELE'VATION A CO C3)_ELE=iN B B=BEAM P=POST/PURLIN CR=(.'fHAIR RAIL DJ=,)QOR JAMB K/B=KAY-BRACE W/B=WIND BRACE MEMBER SCHEDULE MARK SIZE MAT. THICKNESS DESIGN W. F. Bl 2"X 7" ALUM. 0.055 0.120 PER ENG. P1 2"X 7" ALUM. 0.055 0.120 PER ENG. P2 2"X 3" ALUM. 0.050 0.050 iPER ENG. P3 2"X 6" ALIN 0.050 0.116 [PER. ENG. P4 1"X 2" ALUM. 0.046 I'PER ENG. CR 2"X 3" ALUM, 0.050 PER ENG. DJ 2"X 2" ALIX 0.046 E04 ;PER. ENG. 3"X 2" ALIJM, 0,070 PER, ENG, LK/B W/B 2"X 2" ALIA1. 0.090 0.090 PER. ENG. so 4 EL.EVATION C REVIEWED FUk CODE COMPLIANCEE. ST. LUCIE COUNTY STCE �rn cm,M o Z cv W to _ C` Z�WWWN �F �xz Q 3WCL1cF/��� 4 G 00 .a� �UOO.'d ter+ M ti co I I N N Q � N col Cx. c Lo aI 00 Nl3.N ti z x a SHEET NUMBER 3 OF 6 SLPICL PLATE ALLOY: MITER SPLICES SHOWN FOR MANSARD SPLICES, IDENTICAL f061T6 OR 5052H32 FRECIFICATIONS FOR GABLE AND/OR STRAPAIT BEAST SPLICES ... - 8. .o. 0 0 d,, 0 O 0 o O 0 0 -4-1,INTERNAL SPLICE PLATE 0 O QQ..o._ O..fl; 4•,I P SCREW POSITIONS NEAR MITER 03 1 TPd DER �N °F e��ti SCREW POSITIONS NEAR MITER JOINT MAY BE ADJUSTED VGyG TO ACCOMODATE PURLIN, SPACE BETWEEN FASTENERS ALONG MITER JOINT MAY 1 I/2' TO 2', MANTAIN MAXIMUM AND MINIMUM DISTANCES BETWEEN SCEWS: EDGE DISTANCE FOR SCREWS: 3/4' MINIMUM SCREW SPACING: 5/8" SPLICE SPECIFICATIONS PER TABLE 109 BELOW TYPICAL ELEVATION FOR BEAM MITER SPLICE 1 (DETAIL MAY BE ROTATED FOR GABLE RIDGE SPLICE,, AND MAY ALSO SERVE AS SPECIFICATIONS FOR A STRAIGHT SPLICE, MANTAIN PLATE AND CONNECTOR SPECIFICATIONS IN TABLE 109 FOR ALL) BEAM SLPICE DETAILS TABLE 109 BEAM SPLICE PLATE DIMENTIONS #14 SMS PER SIDE PER END TOTAL #14 SMS PER SPLICE FASTENER SPACES ICEINESS LENGTH HEIGHT NUMBER OF SPACES HORIZONTAL VERTICAL 2X6XO.0:50X0. 120 SMB 3/16" 16" 5 1/4" 14 56 3 3 2X7X0.055X0. 120 SMB 3/16" 16" 6 1/4" 14 56 3 3 2X8X0.072X0.224 SMB 3/16 18" 7 1/4" 16 6¢• 4 3 2X9X0.082X0.306 SMB 3/16 18" 8 1/4 18 72-- 4 4 2X10X0.092X0.374 SMB 1/4" 22 88 4 6 IF DESIRED THE 3/8" BOLT SHOWN IN THE WIND BRACING CONNECTION THAT SECURES THE 2 X 2 X 0,90 MEMBER TO THE U-BRACKET AND THE U- BRACKET TO THE ROOF BEAM CAN BE REPLACED WITH FOUR (4) $14 SMS. THE #14 SMS, MUST BE 1/2"FROM THE END OF THE U-BRACKET AND AT LEAST 34P (STAGGERED) FROM EACH OTHER. cotINXTION Mon E sawo SECTION (U•BRACe TCHANNEL 1/4" THROUGH BOLT INSIDE VIEwwITlf as to sMs INTO BEAM OR PERLIN) U-BRACKET H \ (CHANNEL) H (1) FAOI CIC # 14 SMS TWO ON 'a EACH SIDE OF BEAM OR PERLIN euTE BRACE (U-BRA KHANNEL) `— ROOF BEAM 1/8" OD FENDER WASHE # 14 SMS TWO ON \ EACH SIDE OF BRACE � 1/4" THROUGH BOLT PURLIN OR LAVE RAIL SCREEN ROOF DIAGONAL WIND BRAC 2 #14 LAG SCREW FOR WOOD OR 3/8" CONCRETE SCREW FOR CONCRETE, EACH SIDE OF BEAM TRHU 2"X 2" X1/8" ANGLE , LENGTH SUFFICIENT TO ASSURE 2" EMBEDMENT INTO HOST WOOD W/ STTUCO " X 3" X 1/8" ANGGE EACH SIDE OF MIN1Ih1UM 2" LONG) WITH 4 EACH # 4 S. M. S. NTO BEAM WEB BEAM TO HOST HOUSE DETAIL REVIEWED Csocc OUNTY O cn FOR CODE COMPLIANCE ST. %,.�,.�V1E w � zaN � W Lfl zM Wcn� C1] �NC/) aooa: W*kM � CV ~vovp" o L7 UUE-ICU awaacn�ax ax�rHa �U0004 �:Dd ¢�amo¢a d'( M ti co I ti N SHEET NUMBER 40F6 SECTION/S]:DE ELEVATION FOR 2"X4" SMB THRU 2"X1O" SMB 4 SMB POST / COLUMN 2' X 3' X 3/16' ANGLE 2" LONG R/3 EACH # 14 SMS INTO POST WEB 2' X 3' X 3/16' ANGLES 3' LONG (MINIMUM) i 2r-tj- 4'X 8' X 23/8" BRICK PAVER PATIO CONCRETE FOOTER �- 1/4 ' TOP CON W/2 1/2' EMBEDMENT INTO CONCRETE 4- # 10 S. M. S. FROM INSIDE FACE OF POST INTO SCREW SPLINES OF HOLLOW GIRT ( 1" EMBEDMENT MINIMUM.) - MAXIMUN POST HEIGTH (SPAN) 18' -0" FOR NOMINAL 4' PATIO SLAB, DO NOT EXCEED 2 3/4' DEPTH FOR CONCRETE ANCHORS, WHERE CONCRETE DEPTH EXCEEDS 3 1/2' DEPTH, ANCHORS MAY BE EMBEDDED UP TO CONCRETE DEPTH DIVIDED BY 1.25 DETAIL -- ELEVATIONS SHOW THE FOUNDATION CONNECTIONS FOR VARIOUS DEPTH COLUMNS (POST/UPRIGHTS). COLUMNS (POST/UPRIGHTS) MUST NOT EXCEED ALLOWABLE SPANS 2" X 2"/ 2" X 3" OR 3" X 2" HOLLOW HORIZONTAL (GIRT). SELF MATING POST OR HOLLOW POST. PARTIAL ELEVATIONS/GIRT TO POST W/ CONCEALED FASTENERS 2" x 3" PURLIN MAY BE SLOPING OR HORIZONTAL END WALL COLUMN SELECT PER TABLE W. 2 EACH #10 SMS X 4" LONG THRU EAVE RAIL 2X2 INTO SLOPING PURLIN SCREW SPLINES 5 - - - - 1"X 2" OB @ PERIMETER FASTEN PER NOTE # I. cn r- 2" X 2" HOLLOW HORIZONTAL � (GIRT) General Notes 1. Note 1: USE 1/4" X 3" LONG LAGS INTO WOOD HOST AND 1/4" X 2 1/4" LONG CONCRETE SCREWS INTO CONCRETE OR MASONRY CONSTRUCTION 0"EMBEDMENT TYPICAL) /SPACING 24" O.C. AND WITHIN 6" OF EACH PERPENDICULAR MEMBER x � - 4- #10 S. M. S FROM INSIDE FACE OF 1" X 2" OB INTO SCREW SPLINES OF HOLLOW GIRT (1" EMBEDMENT MINIMUM.) rC2 " X 2", 2"X 3" OR 3"X 2" 5 SIZE BEAM PER TABLE 1" X :3" ANGLE COVER PLATE O 1" X 2" OPEN BACK FASTENED TO 2" X 2" P. WITH #14 S.M.S. LAP BEAM WEBS OVER ® 24" O.C. (TYPICAL ) COLUMN AND FASTEN WITH 5- #14 S.M.S. AS SHOWN - COLUNN! (PER TABLE) EAVE CONNECTION DETAIL_ C4 (TYPICAL EAVE CONNECTION)5 3" X 2" PURLIN (MAXIMUM PURLIN SPACING 8'-0" ) SCREEN ROOF BEAMS - SIZE PER ENG. / MAXIMUM SPACING 8' - 0" O.C. BEAM STITCH SCREW ® 24" O.C. TOP AND BOTTOM (#12 SMS TYPICAL) 4 EACH #10 X 2" LONG S.M.S. (TYPICAL) INTO SCREW BOSSES. O Q M � � Z W H E-+ wC/) UZ 't' CJ] .a000C: * 1co It � ♦��R \.J T �r r C7 1n iiw ILLly m m W " Z�Q.N \ ��M LLFX o \\l cq J�(� Jz N W v) W �W •I�0 L1 W F- W WJz-ICLC7 Q a a m Q = = A nQ.(=jvfnd� ram' 20)m E-- �O 1L H W REVIEWED FOK z CODE COMPLIANCIL o ST. LUCIE COUNTN" � 0 U SHEET NUMBER 5OF6 W z 0 x a