HomeMy WebLinkAboutAbliss - 1324 Nettles - rev 9-8-20 architect drawingSTAIR FLAN (�) risers 5) � 1/1�" high (4) Treads 5) 11" deep SCALE 1/2" = I'—O" TYPICAL NOTES: I. Contractor to verif ALL notes and dimensions prior to proceeding with work 2. Contractor to STWICTLY enforce ALL OSHA Requirements. 3. ALL Lumber to be used as Beam, Rafters, etc... to have a min. 1,500 psi fiber bending stress. 4. No dissimilar metals to touch. S. ALL wood in contact with concrete shall be pressure treated. 6. ALL wall dimensions are nominal and not finished wall or stud dimensions. -4" x -4" x I'-10"d SYP 42 PT Post 2" x 6" PT Joists Provide Simpson LUS26 Hang 0 w/ (4) IOd nails into Joist and (4) 10d nails into Beam Supporting 1165 lbs. max. uplift cal 5/8" A325 Ttoubolt 9 each Beam to Post Connection 3,_0„ STAIR DETAIL r— N 2" x 12" PT Stringer FRAMING PLAN Bolt 2" x 6" handrail to post through 2" x 2" blocking using (1) 3/8" x T carriage bolt with 31411 washer at each post Round top edges to comply with FBC R311,11.3 2" x 2" PT wood pickets at .4" O.C. attached with screws to railing support member 4" x 4" x 6'd PT SYP 42 Post 2" x 4" PT Railing support 2 x � PT tread I" nosing I" x � I/W'd Riser 1/2" dia thrubolt Scal&: 3/4' = i'—O" 42 2 PT ung Stainless Steel Wood screws 9 ea. Joist SCALE 1/2" = 1'-0" STAIRS FRONT ELEVATiON SCALE: 3/8" = I'—O" STAIRS SIDE ELEVATION SCALE: 3/8" = 1'-0" FOUNDATION FLAN SCALE 1/2" = 1'-0" FOUNDATION NOTES: I. Any changes to plans must be submitted to the architect for approval prior to proceeding with construction. 2. Contractor shall be responsible for verification of all notation and dimensions prior to start of construction. 3. ALL Concrete used for slabs shall be 2,500 PSI concrete min. 4. Soil bearing capacity assumed to be 2500 psf and stable. This shall be confirmed in writing by soil testing report done by others prior to the start of any construction PERMiTTING iNFORMATiON (FORM 100) Florida Building Code Residential: 6TH Edition and ASCE -1-10 for Wind Loading Building Design is: Enclosed Risk Category: II Wind Speed: 165 mph ultimate Mean Deck Height:4'-6" to mid rail. Sub jectabilitg to damage from: Weathering: Negligible Termites: Vero Heay4 Wind Velocity Pressure = + 4-1.0 PSF Wind Exposure Classification: C Shear Walls Considered for Structure? NO Continuous Load Path Provided? Yes Are Components an Cladding Details Provided? Yes Minimum Soil Bearing Pressure: 2,500 psi, Presumptive: X Bg Test: psi STRAPPING SCHEDULE MTS 12 MTS 12 I Simpson MTS 12 hurricane anchor at each truss (24" o.c.) supporting Max. 1,000 lbs. uplift w/ (14) IOd x 1.5" nails Bolt 2" x 6" PT handrail to post through 2" x 2" blocking using (1) 3/8" x 9" carriage bolt with/ 3/4" washer at each post Round top edges to comply with FBC R3111.1.3 2" x 2" PT wood pickets at 4" o.c. attached with screws to railing support member 2" x 4" PT Railing support Tread 4" x 4" PT wood post Nail Stringer to post using (4) IOd nails Handrail Detail Scale: 3/4" = 1'-0" Termite Protection for New Construction as per F.B.C. 181L1 CONTRACTOR TO REFERENCE F.B.C. BUILDING 1816.1 FOR FURTHUR REQUIREMENTS Soil treatment used for subterranean termite prevention inside the foundation perimeter shall be done after all excavation, backf filling and compaction is complete. If soil area is disturbed after initial chemical soil treatment, area shall be re —treated with a chemical soil treatment including spaces boxed or framed. Treatment must be in accordance with the rules and laws established by the Florida Department of Agriculture and consumer services. Protective sleeves around piping penetrating concrete slab on grade floors shall not be of cellulose —containing materials and shall have a min. wall thickness of 0.010" and shall be sealed within the slab using a noncorrosive clamping device to eliminate the annular space between pipe and sleeve. NO TERMICIDES shall be applied inside the sleeve per FBC Plumbing 305.1.2 Digitally signed by Daniel Braden Date: 2020.09.08 10:49:08-04'00' CIO O v �7A U a�Qz C] O LL N r- 6— cil 1L T U W w w z III cli W o O LU =3 O ..z W W�" O � �' cy cy q; — < U (X) M v L z i � UU 3 m (� ~ LLI q3 x LL r l < `r a SHEET u0: I. OF I. JOB NUMBER: 20-1-41 '0%,& R. RR ao�� o ®® o AR 977770 o� O o���o o�oo��000C co . ��0 to d)