HomeMy WebLinkAboutBuilding PlansGulf Coast Supplg and MFG 5v Crimp Metal roofing FL a11651.12
2L ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12' o.c. max spacing over ASTM D
ftgpir 2) 30 lb felt underlagment installed with min. 4 side laps and L' and
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
paled L` oc_at-all lje._and two�staggered Lrows 12" c.c. in field. Attach
5/5" thick cut coral coral finisnea stucco Dane
finished stucco bands Rl 11('" HT ELEVATION
12
SLOPE,
SCALE: 1/4 - I'—O"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411451.12
26 ga. 5v crimp metal roofing attached to plywood deck using u9 x 1.5'
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4 side laps and V and
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced L o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trussea using attachment detail on this sheet
Im-
!17-71LEVATION MOTES:
Gulf Coast Supplg and MFG 5v Crimp Metal roofing FL #11651.12
2L ga. 5v crimp metal roofing attached to plywood deck using #41 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4 side laps and L" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced V o.c, at all lapis and two staggered rows 12" o.c. in field. Attach
eck to trussea using a tachment detail on this sheet
/8" thick x 8"w cut
)ral finished stucco bands
. f W � Wu wi w stucco on i.9Picai concrai.a
finished stucco bands block construction
REAR ELEVATION
- Overhangs at 1'-0" unless otherwise noted on Roof Plan
Roof pitch at -4.12 unless otherwise noted
Any changes to this plan shall be submitted to the architect
for approval in writing prior to starting construction.
- Return ALL Stucco Bands into Window or Door.
L—J . 5/8" thick x 8"w cut
3 coral finished stucco bands 3
5/8" thick light textured
stucco on typical concrete
block construction
LEFT ELEVATION
SCALE: 1/4' - 1'-0'
12
4 1 SLOPE
SCALE: 1/4' = II
Gulf Coast Supplg and MFG 5v Crimp Metal roofing FL #11L51,12
2L ga. 5v crimp metal roofing attached to plywood neck using #9 x 1.5"
wood screws with self sealing washer at 12' o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4 side laps and V and
laps fastened with corrosion resistant tin caps and with 1..25" ring shank nails
spaced L" o.c. at all laps and two staggered rows 12" o.c, in field. Attach
deck to trusses using attachment detail on this sheet
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one layer of 15 lb felt using 8d nails. Substrate
to be 19/32" CDX Plgwood marled at V o.c.
in field and edges with 10d ring shank galvanized
nails into truss webbing.
5/8" thick x 8"w cut
coral finished stucco bands
® ®.• nn 5/8" thick x 8"w cut coral finished stucco bands
A.F.F. 5/8" thick light textured Finish Columns with
stucco on typical concrete 5/8" thick cut coral r d 6
block construction finished stucco bands
\ , * I
FRONT � L � Y � I �l folug COPY REVIEWED FOR
CODE COMPLINC,
SCALE; I/4' = IIST. LUCIE COUNT 4�)a
2" x 4" top plate I ' 1/2" drgwall ceding on truss bottom cord
1/2" drywall on
2" x 4" studs at 19" o.c.
base —board 11 11 / 2" x 4" P.T. bottom plate
\ 4" concrete slab with fibermesh OR
Vxt' #10/10 WWM on L mil Visqueen over
clean compacted termite treated fill
Interior Non -Bearing Partition
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING,
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING, CORP.
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING INFORMATION (FORM 100)
Florida Balding Code Residential: Lth Edition and ASCE 1-10 for Wind Loading
Buildin Design is: Enclosed Risk Category 11 Wind Velocity: ILS mph ultimate
Mien Roof Height. 11'_O' Rod Pitch: 4:I2
Internal Pressure Coefficient: *a_Ie
Sub,lectability to damage from: Weathering: Negligible Termites: Very Heavu
Width of Rod End Zone: 3•_ l' Wind Speed: mph ultimate
Wind Exposure Classification: C 1.21 x O.L 0.�2L
Adjustment factor for Exposure Haight: ASD design
Load Combination: ASCE 1-10 Section 2.4 DL+LL; DL+O.LWL; OADL+O.&WL
Components t Cladding Wind Pressure (NET) Roof Zone: I. +20.L/-332A pal
Rod Zone: 2. +20.L/-57.0 pat
Rod Zone: S. +20.4/-84.0 pal
Components t Cladding Wall End Zone Width:'- '
Components t Cladding Wind Pressure (NET) Wall 4. +35.8/-38.'I psf
Wall Zone: S. +35.8/-41.8 pot
Components t Cladding Wind Pressure (NET) on Garage Door; +32.0/-40.3Pat
Shear Wells Considered for Structure? yes
Continuous Load Path Provided? YY��
Are Components an Cladding Da1:T Provided? Yes
Minmwm Soil Bearing Pressure-2.500 psi. Presumptive: X Bu Test: psi
ROOF LIVE LOAD. 3t1_ paf ROOF DEAD LOAD: 10 paf
JOB ADDRESS:
Roof Zone I
Wells Zone 4
Roof Zone 2
Wa
Ills Zane 5
END ZONE
RCorner Zones
oof Zone 3
FLOOR PLAN
CRASH POST DETAIL
TYPICAL NOTES: SCALE 1/4" = 1'-0"
F R102 5
N.T.S.
1. Contractor to verify ALL notes and dimensions prior to
high by 4" diameter
steel crash post. Floor
steel
proceeding With work.
Flange with 4 - 3/8"
2. Contractor to STRICTLY enforce ALL OSHA Requirements.
expansion bolts into
51a (3/8"t 50 ksi steel plate)
3. ALL Lumber to be used as Beam, Rafters, etc... to have
a minimum 1,400 P.S.I. fiber stress.
4. No dissimilar metals to touch.
2h° 2°'A"
5. ALL Concrete used for slabs shall be min. 2,500 PSI concrete.
ALL Concrete used for vertical filled cells, cont. tie beams etc.. to
m
shall be 3,000 P.S.I. concrete and/or -4,000 P.S.I. grout mix
6. Drywall be leveled to bottom
4'
at ceilings shall and attached chord
of trusses with screws per BC .3. .
1. ALL wood in contact with concrete shall be pressure treated.
8. ALL wall dimensions are nominal and not finished wall or stud dimensions.
9. ALL plumbing fixtures to be low flow.
10. Contractor to Provide Drain at water heater in accordance
with the current edition of the Florida Plumbing Code.
11. Contractor to Provide a 2'-8" wide door at one bathroom for 2°
handicap accessibility requirements.•
12. Lowest finished floor to be set by Governing Building Department `
surveyor to set in field.
13. Separation between residence and garage shall be per FBC R302.6
14. Door between garage and residence shall be 1-3/4"t 20 min. rated door
W.H. = Water Heater
15. Wall and Ceiling shall have a flame -spread classification of not greater than 200 per FBC R302.9.1
16. Wall and ceiling finishes shall have a smoke -developed index of not greater than 450 per FBC R302.9.2
11. All exposed attic insulation materials installed on attic floors shall have a critical radiant I" x V P.T. Buck
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation block with case han
materials exposed on the underside of the roof deck or on the attic walls shall comply prior to door attacl
with F.B.C. R316 - see permit info box of code edition
18. Gy�(ppsum board material shall conform to ASTM C34, C19, C415, C514, C630, C931
C960, C1002, CIO'4-I,C1111, C1118, C12-18, C1395, or C1396 and shall be installed
according to the following: (FBC R102.3.5)
Dr wall
Th'Wall s
Location
Orientation
Framing
Member
Max. spacing
of Paatienera
Nail sizing options for
drygwall into
Spacing
installation of
Nails
Screws
MaxImum
wood framing mom era
2" x min. thickness
Ceiling
Perpendicular
24"
1"
12"
13ga 1 3/8' long with 19/64" head
0.098" diameter x 1 1/4' Ionggail
y2
annular -ringed or 5d cooler n
0.080" dia. xx 1 5/8" long with
Walls
Either
IL"
gx
10
Direction
15/64" head
OR
Gypsum board nail 0.084" dia.
x 1 5/8, with 9/ 2" head.
Ceiling
Perpendicular
24"
l"
12"
13ga 1 5/8" long with 19/64" head
0.098' diameter x 1 3/8" Ion g
annular -ringed or bd coder nail
OR
0.092" dia. xx 1 1/8" long with
Walls
Either
IL°
8n
16"
Direction
1/4 head
OR
Gypsum board nail 0.0915' dra.
x 11/8" with 19/64" head.
Install SGD thru buck into
block with 3/I6" tap -con with
11/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at head per product approval
Use 3/I4" tap -con with
1 1/2" penetration at L" o.c. max.
from each corner and 20" o.c. max
thereafter at sill per product apprc
19. ALL ceramic the surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, A136.1 and A13-1.1
20. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, OR C1118 and installed I.A.W. manufacturers recommendations shall
be used as backer for the wall the in tub areas and wall panels in shower areas.
21. Insulation including facings such as retarders or vapor permeable members installed
within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accompanying smoke
developed index not to exceed -450 when tested in accordance with ASTM E 84.
Insulation shall comply with F.B.C. R316.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #IIL51.12
2L ga. 5v crimp metal rooting attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4 side laps and V and
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced L" o.c. at all laps and two staggered rows 12' o.c. in field. Attach
lack to trusses using attachment detail on this sheet
Simpson HETA 20 or equal
hurnc ne nchor et each truss 12
with PO) 4od x 11/2' nails PRE-ENGINEERED TRUSSES
( 244 o.c.) supporting Max. 4 at 24"o.c. TYPICAL
18101b&. uplift ( h d b f t )
Aluminum Dnp ia
Edgy t Fasc
2" x 6" Sub -Fascia
Kaycan full a vent vmpl soffit I
using 1/8' dia shank x 1.5' long
roving pals with 3/e' dia. head
product approval -see chart sl
5/8" thick light textured
stucco on typical concrete
block construction
u5 bar vert. w/
30" overlap
at each filled cell
Grade
a op rawinga g manu ac urer
R-30 blown fiberglass
in bottom chord or trusses
I/2' drywall with smooth finish
Two rows or beam block filled with concrete
and (1) #5 bar cont. in each row. substitute
ad precast lintel filled with concrete and (U x5
bar cont. for bottom row over opening&
al 1/2" dr well over I" x Purrin
strips a IV o.c. with R4.1 A -roll
insulation on typical 8" Block walls
All drywall to be installed per FBC R902.3.1
T and shall meet all pertaining ASTM codes.
ro Mortar to be Type "M" only proportioned per FBC RLO-1.I
and Mortar Jonts shall comply with FBC RG01.2.1.
Provide Dur-O-Rock at all wet areas (ex, showers, tubs etc...)
FIII cell with concrete and
(U #5 bar vert. (typical).
Max. appacing shall not exceed
Wood 48" unla 6 otherwise noted
see foundation plan notes for
ass spacing at openings
4" concrete slab with fibermesh OR
6"xL" u10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
or
-
I'11-IIII,
I
18 Concrete footing
a5 bars cunt. and �5
14° transverse bar& at 48" O.C.
TYPICAL SECTION
Scale : 1/2" = 1'-0'
led to Masonry Beam
lad rmis
in
AREA CALCULATIONS
Living A/C = 1446 sq. ft.
Front Porch = 1,41 sq. ft.
Rear Porch = 200 sq' ft.
Garage = 321 sq. ft.
Total Under Roof= 2108 sq. ft.
Total Cubic Ft = 11,568
z' VTR
® 2
x
i 2-
I 9ATF
L V-1
I LAY -I 21,
i WH-1 2" x
we -I 2"
2" LAUNDRY 2" 3" 2" a• AAv r VTR
3" BT-I 3x 8-1
KTICHE12u i
2 LAv-i
3" 2" ryx
PLUMBING RISER
we-i BATH a2
To septic
I" x V P.T. Buck nailed to f O
block with case hardened nails
Head prior to door attachment
fixed door
sliding door
al
n
Masonry Well
fir:':
Bottom Trac
Typical Flooring
Bill
Install SGD thru buck into
block with 3/16" tap -con with
S
l i d i n g
D O or
D e t a 1 l
I penetration at G" max.
from ."
from each corner and 20." o.c.
max
thereafter at Jambs per product
approval Jamb
At Masonry Wall
NTS
Window Schedule
Mark
Size
Rou h O en.
Window Description
PRESSURE ZONE
I.
4'-5ie"x 5'-3ia°
54ia'x L3i4'
Single Hung
ZONE 4
2,
V-tie"x V-3 ie"
15' x L3 i;'
Single Hung
ZONE 4
3.
'-2' x 3'-2 I/2"
21i2"x 38%a"
Single Hung
ZONE 4
4.
4'-5ka'x 4'-2%"
54Ys"x 54Ya"
Single Hung
ZONE 4
ALL Windows to be aluminum windows w/ tint
and mullions per elevations.
ALL windows to withstand pressures in permit info box on sheet I
ALL windows in bathrooms to be tempered
All rough opening dimensions to be verified bg contractor
with manufacturers specs prior to construction
Door Schedule
Mark
Size
Rough Opening
Door Description
PRESSURE ZONE
A
9'-0" X 7'-O'
108" x 84'
Overhead Garage Door
ZONE 4
B
3'-0' X L'-8"
41'/4'x 83%"
Fiber lass Panel - Inswing
ZONE 4
C
L'-O" X L'-8'
tm
'14" x 81 '/," aidrr cemi,
Sliding Glass Door
ZONE 4
D
2'-O" X L'-8'
Solid Core - Wood - L-Papal -Bi-Fold Finished
24" x 81 %2"
E
2'-66 X V-8'
Solid Core - Wood - L-Panel
F
5'-0" X V-8"
Solid Core - Wood - L-Panel - Br-Pold
G
2'-8" x P-8" x I /4'
Solid Core Wood, Steel, or Masonite Door
H
2'-e" X V-e"
Solid Core - Wood - L-Panel
U
2'-L" X L'-8"
Solid Core - Wood - L-Panel - Bi-Fold
K
2'-8" X L'-8"
Solid Core - Wood - L-Panel - Bi-Fold
ALL Exterior doors to withstand pressures stated in permit info
box on sheet 1$1
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET #1
All rough opening dimensions to be verified bg contractor
with manufacturers specs prior to construction
14'-0" 9'-6" 2"
OPTIOA
(2-)PATIONSLAAB
EGRESS
1T-8"
N
°
MASTER
U=
BEDROOM
Jill V-O" A.F.F.
inn
ru)
P
Flat Ceding
Rod E'Shelf
I
✓anity to 1115e v I Is
14 V' hig
�CLO E I
I�
LINEN
ABINE
I8
Rod
t Shelf
0
Lu
00
DW `
I
Id
--ter -4
a
W
ATH
~
°
I
°
T
;.,
KITCHE
Yen
Dryer
thr
h wall
O
L -
i
-
O1..1
Flat Ceiling
°
I
L'-0
Upper cabinets to
-
ext nd over Ref.
n
2' filler-,r+
i
"� Ilyd-V�t
-1
A C
R-li Betts lasdeti W.H.
i
I
4 4 Steel Ballard
Sas detail oA J,bl AERL I „
I 22" x 64'
Provide auto Attic Awmas
IL
closer 1 weh h8ht_ I
L____ J
°
150
Amp
Meter
Panel
o
GARAGE
A.F.F.
G
Flat Ceding
C
or-----------------i
' I Block wall in
<r I garage to be
struck block
Q I I
T I I
I
o I ® I
0 0
L3'-5" 1 9'-0.
1 15'-10"
12" x 12" Concrete column /
block filled with concrete and
(2) #7 bars vert. tied Into
lintels above
Covered Porch
8'-O" to 9'-8" A.F.F.
Vault Ceding
GR AT
ROOM
I
I
I
I N
2" x 6" knee -wall 8' O" to T-8" A.F.F.
below counter top I Vaulted Ceiling
DINING
ROOM
d� I
I
Vanity to be
34 Yz"high
" High 418Well 9%,,, ll'-O
i
y�2n (V
- Uverhang - -
4'-1. LEW
11.
_
I E BATH $
Rod t Shelf C
-I
o!I
�01
8'-0" A.F.F.
I
:22 _ y
Flat Ceiling
in
SECOND m
Y
EnCaCRIE
BEDROOM I
-
ELI MT
r
i
°
00,
EGRESS
N
11
I
in
in
N
T
O
O
C
V E R
D
12" x
12" concrete
olumn block filled
PORCH
with con
rate and (2)
1 bar& vert. tie
p
L'
2"
/
into lintels
II'-L"
bove
\ L."
;n
a
3'-5" 2'-8" 2
10 4'-2" 5'-4"
aD
V_
REVIEWED FC
CODE C (APLIANOL
ST. LUCwZ: 1.-_'t')UNTV
j
Attach buck to block wall with
1/4" dia. Eleo cone screw& with min.
1 1/4" penetration at 12' o.c. max
and 4' max from each corner thru
Exterior face 2' x L" PT Buck
of wan
apes
I"x4' P.T. Buck nailed to INSTALL VULKEM BLOCK SEALANT tie Wood screws thru iamb into buck
lock with case hardened nails ON ALL JAMB, HEADER, AND at each hinge and 15' o.c. is and
Detail at Windows prior to window attachment SILL BLOCK PRIOR TO BUCK Detail at Door prior to door attachment
INSTALLATION
NTS NTS
Braden It Braden AIAe PA Wynne Buildmg Corp. Date Drawn : Revisions : Sheet Comm
Architects - Planners 3-25-20 //
-411 S.E. Coconut Avenue T h Grand Carlton GARAGELEFT Drawn bg: 12 - 2 f
Tel : (112) 281-8258 C.C.U. 2 -
Fax : (112) 2 81-8283 5 apish Lakes Checked by:
E-mail:13
bradenala comcast.n t Stan
Lucie Count Florida D.R.B. OF 5
C.«kmww« CI LLdgGiL ttee�nnnna°s y
Install windows thru buck into
block with 3/16" tap -con with
I 1/2" penetration at V o.c. max
Prom each corner and 20." o.c. max
thereafter at iambs and 20' o.c. max.
Exterior face at head and ell per product approval
of wall ---\ / \ Buck to be I' x 4' IFT
r—- ------i
,7 I lI_U1.1 1 UN/"IIII INk./ I T__
I. ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
2. ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI
BE 3000 PSI OR 4,000 PSI GROUT MIX AT 28 DAYS
3. POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
4 GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 6X6 10/10
WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
5• LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL IS BROUGHT IN. FILL MATERIAL SHALL CONSIST OF
CLEAN GRANULAR SAND CONTAINING LESS THAN 10% MATERIAL
PASSING THE US STANDARD NO. 200 MESH SIEVE. PLACE
STRUCTURAL FiLL IN LOOSE LAYERS OF 12" IN THICKNESS AND
COMPACT EACH LiFT TO AT LEAST.95% OF ITS MODIFIED DRY
PROCTOR VALUE.
6• GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
ATTENTION OF THE ARCHITECT.
GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
FOUNDATION CLAN
8. SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
9. DESIGN LOADS ARE AS FOLLOWS:
ROOF (DL+LL) = 41 PSF
WIND VELOCITY = PER PERMIT INFO BOX ON SHEET #1
EXPOSURE = I
10. ALL REINFORCING STEEL SHALL BE GRADE 40, MEETING ASTM A-16, t
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 30-1 STEEL.
II. ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
BOLTS AND FRAMES SHALL BE iN PLACE PRIOR TO POURING CONCRETE.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
12. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTING: 3"
BEAMS: 1-1/2"
13. LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
14. USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1400 PSI
IS. ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000
PSI OF NO.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE.
16. ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
I. Any changes to plans must be submitted to the architect
for approval before proceeding with construction.
2. Contractor shall be responsible for verification of all
notation and dimensions before starting construction.
3. Soil conditions assumed to be 2500 psf. Should any other conditions be
encountered, the architect shall be notified in writing for revision
4. Verify all recess thickness at showers, tile, etc....
S. Contractor to provide filled cell with concrete and 1 45 bar Vert. at 48"
o.c. max. Provide (1) filled cell on each side of openings up to 5'-11" wide.
and Provide (3) filled cells on each side of openings from 10'-0" and up
Contractor to see plans for any other condition used. Foundation walls
shall have filled cells at 24 o.c. unless otherwise noted (see section)
6. Contractor to provide for Form Board Survey — Form Board Survey
to be provided to Truss Company prior to truss construction
1. Contractor to provide for soli test prior to construction and provide
a copy of soil test to architect for review prior to construction
8. ALL Reinforcing steel shall be grade b0, meeting ASTM A —IL and
A-35 specifications. ALL Anchors to be A-301 steel.
9. Provide a minimum of 3" concrete protection at footings and
1-1/2" concrete protection at beams for ALL reinforcing bars.
#5 bar Vert. w/ Fill cell with concrete and
30" overlap (1) #5 bar vert. (t ical). Thicken edge to 8"x8"
d yP 9
SCALE: 1/4" = 1'-0"
Termite Protection for New
Construction.
Soil treatment used for subterranean termite prevention
inside the foundation perimeter shall be done after all
excavation, backfilling and compaction is complete.
If soil area is disturbed after initial chemical soil treatment
area shall be re -treated with a chemical soil treatment
including spaces boxed or framed.
Treatment must be in accordance with the rules and laws
established bg the Florida Department of Agriculture and
consumer services.
Protective sleeves around metallic piping penetrating
concrete slab on grade floors shall not be of cellulose
containing materials and shall receive application of
termicide in annular space between sleeve and pipe.
at each P lle
i c Max spacing shall not exceed with concrete and 4" concrete slab with Pibermesh OR
Wood 48" unless otherwise noted one #5 bar continuous VxV #10/10 WWM on 10 mil Visqueen over
Base see foundation plan notes for clean compacted termite treated Pill
spacing at openings
4" concrete slab with fibermesh OR GRADE
VxV #10/10 WWM on 6 mil Visqueen over
/ clean compacted termite treated fill °D _
Grade
IIII
- 14 w x 18 d Concrete tooting
with (2) #5 bars cont. and #
h 5
i �,' IIII II transverse bars at 46 o.c.
Vtf=l/
TYPICAL FOOTING: DETAIL
SCALE 1/2" = P-O
4" concrete slab with fibermesh OR
(VxV #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
#5 bar cost.
Step per
foundation plan
\j--1 DETAIL AT
12" x 12" concrete column
block filled with concrete
and (2) #1 bars vert. tied
into lintels above
Top of Tooter
16" below finished floor
#5 bars cunt. bottom steel
RAGE STEPDOWN
SCALE 1/2" = 1'-0"
30" q
LUMN FOOTING DETAIL
30"x3 14" concrete
column footing with (4)
45 bars each way
i amm*h
n
C
E
Contractor to provide
proper foundation chairs
for proper steel installation
PORCH
SLAB EDGE DETAIL
30" min.
SCALE 1/2" = 1'-0"
#5 bar vert. w/
30" overlap
Corner Steel Lap
at each filled cell
nts
#5 bar cont. in curb
Fill cell with concrete and
(1) #5 bar vert. (typical).
Filled Cell Masonry Column With One
Curb height
Max spacing shall not exceed
48. unless otherwise noted
#5 From Footle To Tie Beam
9
Verify based on
Bead
see foundation plan notes for
Conc. Fill To Be 3000 PSI
foundation plan
spacing at openings
See Floor Plan For Location
4" concrete slab with Pibermesh OR
VxV #10/10 WWM on 6 mil Visqueen over
w
clean compacted termite treated fill
Grade
❑
),
-
_
Single
Filled Cell Column
- l
III
NTS
- ;
14"w x 18"d Concrete footing
with (2) #5 bars cont. and $5
IL
transverse bars at 48" o.c.
Filled Cell Masonr Column With One
y
I"
46 From Footing To Beam Each.
GARAGE CURB
DETAIL
Conc. Fill Be 3000 PSI
See Floor Plan For Location
Plan
SCALE 1/2" = III -Off
2" x 6" PT wood secured with
1/2"dia. x 6" expansion anchors
with 2" sq. washer at 18" o.c. overhead door track secured to wood
jamb per manufacturer's product approval
Garage Door Jamb Detail
GARAGE DOOR TO WITHSTAND PRESSURES STATED NITS
IN PERMIT INFO BOX ON SHEET #I. SEE PRODUCT
Double Filled Cell Column
NTS
Braden it Braden AIAe PA
Architects - Planners
411 S.E. Coconut Avenue
Tel : (112) 281-8258
Fax : (112) 281-8283
ff B E-mail: bradenaiascomcast.net
14'-011 _1-' :�G I eg�hi 1 20'-0"
I
PATiO/SLAB-
---- —I ° -------I °° T
I
8 0
Q
Filled under
I
QI
FI
girder above
above
I
24"
O
1
I
Rear Patio/Slab
O
r J
to
be poured separate
from the house slab.
IU
®I
� I
o
I
I
Thicken footing to
24% x 14"d x 24"L
I
I
FI under filled cell I a
under girder bearing. L — — — — — — — —
� °
° I —Fi
m I Rear Patio/Slab to
u U E be flush with bottom of
as S� u I sliding door recess
h I Slope 1/2"
Clip I
°I I
I I
I I
I
°I Q�
° 32'-8"
i
H.B. I I
I 4" concrete slab with fiber ash OR I
6`1 1110/10 WWM on 6 mill V squeen over
I clean compacted termite tr ated fill
I
I
I
°I
_; ❑ ' ` FI
I I
_ FI ° I � � ❑ °
4, O„
i ❑
j I
�——
I
#I I 4'm Sisal Ballard
FI
r filled w/ Concrete 0
F5 moo='1113 I I'GI I
I IFQI ay
I E�� I 1 I
I Et! I I
I
I 3vE I L.— a FI I
°
A �
aLI
E O \
I ry v 0 U
OQ
U I ua
`r � o
"
{L
in
L----------� °
F
o ° o ° v
1.5" Recess for o °
---
----
p
— — —
o
A-
Garage Door
JQ
3'-5" 9'-O" 3'
BIJ
12" x 12" concrete
column block Pille
with concrete
gqnil (2)
#Z baJoe rs Vert, ti
mto lintels
abova
Wynne Building Corp.
The Grand Carlton
Spanish Lakes
St. Lucie County Florida
9
Em
°U
MJc
tL
CS COM LIA ACE
BOCK
FOOTING
SCHEDULE
Mark
SON
tam
9FI
14"W
x 18"D
MONOLITHIC FOOTING
WITH
2 #5 BARS CONTINUOUS
F
12"W
X 120D
MONOLITHIC FOOTING
WITH
(2) 45 BARS CONTINUOUS
R30"
x 30" x 16"D
COLUMN FOOTING WITH (4)
#5 BARS EACH WAY
r_
e"W
x 8"D
THICKEN SLAB EDGE
WITH
1 #5 BAR CONTINUOUS
F5
IYW
With
x 18"D
Curb at Garage
MONOLITHIC FOOTING
WITH
2 #5 BARS CONTINUOUS - CURB a O'-On
Date Drawn Revisions : Sheet Comm #
GARAGE a-25-20 12 — 2 �
LEFT Drawn by:
C.C.U.
Checked bg:
D.R.B. OF 5
ROOF SHEETING
ATTACHMENT DETAIL
I. Minimum Nail Size = 8d ring shank (min. 2.5" long)
2. Minimum Screw Size = 48 x 2"
3. Minimum Sheathing Thickness 19/32" CDX Plyywood
4. Use nails or screws bas d on ress re for root stated
in permit info box on these pans for zone 3
Ke
Area
Edge
Field
Fastener
Max.
Zone I
6
6
8d ring shank
45 psf
Zone 2
14
6"
8d ring shank
16 paf
Zane 3
8d ring shank
84 psf
** Zone 3a
`"
6"
#8 wood screw
112.5 psf
** Use nails or 9(;rews based on res$ure for r of stated
in permit info box on these plgns for zone 3
Concrete
/ Lintel
Column
to
Verifg with Plan
12"x 12"
Iumn Block
Provide #5 bars with on. 48 bar
diameters overlap into beam. Tie
filled call steel into continuous
beam block steel. t\
Provide Cast -Crete = -r
BUS-OB/OT precast
lintel set in mortar
Min. 8' Bearing
Provide #5 bar set in pre -cast
lintel into beam where length of
the opening calls for it.
2 -r_7127 7,-
ovide PT Buck
:ached per jamb
ails into filled a
4" Pre -cast
Sill
Filled Cell
Provide #5 bars with min. 48 bar
�iameterm overlap in Pilled cell. Tie
filled cell steal into continuous
factor steel.
JiI r�
• r - Concrete Footing
foss looter schedule
roe exact sized
DETAIL AT WINDOW OPENING IN
CBS WALL Scale. 1/2" = I'-0"
�l
N
SINGLE PLY REAR GIRDER TRUSS
Nail 2' x 4' blxkin.0 to vent. leg of
truss with 10d x 1.5 nails at 4' o"c.
install Simpson MGT into wall win
5/8" dia. threaded rod set mat. 11.
into net beam and (22) IOd nails into truss
Trusses at 24' o.c.
see shop drawings{
bg others �4
R-II batts
Rebar
Rebar 48 Bar Dia.
Min.Ovcrlap TRUSS BLOCKING DETAIL
Lintel Attachment AT GIRDER STRAPPING
AT CENTER BEARING POINT
NTS
1/8" thick light textured stucco Installed per
ASTM C 92L over ASTM D tgpe 2 paper backed
wire lath nailed to substrate through one layer of
ASTM D Type 2 felt paper using 8d nails. Substrate
to be 19/37 CDX Pggwood nailed at L o.c, in field
and edges with IOd ring shank nails into studs.
BEAN SCHEDULE
Mark
SIZE and Description
Gulf Coast Supplg and MFG 5v Crimp Metal roofing FL #11651.12
2L ga. 5v crimp metal roofing attached to plgwood dock using #9 x 1.5"
a 2) 30wlb feeltPunderle mentenstalled with min. All' ode over
(t oranASTM
V and
laps fastened with corrosion 9 resistant tin caps and with 1.25" ring shank nails
spaced V o.c. at all Ieepps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachmant detail on this sheet
BI
Two rows of beam block filled With concrete and 1 #5 bar
continuous In each row. Hook vert. bar over top bar Wlth
#5 90e bend bar With a 10" min. lap at top bar.
LINTEL SCHEDULE
Mark
or W
i
Ca
Caroi
Rows or
yH
e
steel
a�
Steel
Lamdd
(PLF)
t
(PLF)
lob
(PLF)
L22
2'-4'
3'-4'
BPa-08/IT
1
85
3001
1561
1024
L31--Lp'�
4'-0"
�9-08/IT
I
#6
26LI
13L3
103'-M
L45
4'-6'
W-10'
aFa-Ob/11'
1
#5
BOB
404
331
1.60
6'-0"
L'-L"
Ada-O8/1T
1
#6
12H
S35
121
LLO
or -Se
11-C
ePa-OBIT
I
s6
Ion
121
934
Lao
a' -Of
1'-4'
BIR0-SS/2T
1
*5
2
95
152
511
512
L40
T-O"
W-6'
8f'a-0/2T
1
85
2
06
643
530
401
1108
1'-O'
10'-6'
SFIL-I5/2T
ONE
1
#5
2
85
533
us
401
LIDO
10'-O"
W-4'
$IR8-0/2T
1
#5
2
$5
582
414
452
LiOOS
10'-0"
n'- le
BPU-18/2T
ONE
1
85
2
66
r366
1028
452
LI20
IT-O"
W-4'
Ida-18/2T
1
#5
2
#5
411
426
324
1.1208
12'-�0/m"
IS'-4'
AIL-18/2T
ONE
1
#6
2
#6
1016
110
324
L140
W-06
W/..{-4•
SPI6-Ib/2T
ONE
1
#6
2
86
1250
i01
2541
LW
W-OR
IT-4'
SIRS-0/2T
1
$5
2
85
300
M2
114
Lht08
w-O'
11'-4'
SPIL-18/2T
ONE
I
#5 1
2 1
86 1
150 1
$00
144
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION. HANDLING INFORMATION, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-O" LONG ARE TO BE PRESTRESSED.
Simpson HETA 20 or equal
hurricane c a at
with (10) �a x Ia l/2e'ch mileruss -
( 24" o.c.) supporting Max
18101ba. uplift
Aluminum Drip -
Edge t Fascia
12"
2" x V Sub-Fascl
Kagcan full o vent vinyl spirit installed
Wing 1/0' dia shank x IS' long goly.
roiling nails with 3/8' di& head per
product approval -see chart sheet #1
12' x 12' concrete column
block filled with concrete
and (2) #1 bars wart. t"
into lintels above
thicken edge to 8"x8'
with concrete and
one #5 bar continuous
BEYOND
Top of footer
IL' below finished floor
a
�`.Ii1l1
12
4
Aluminum Drip
Edge t Fascia
Flash and Counter v
Plash
Nail ledger to
Gable and truss
with (2) IOd ils
at each web
3/4' penetration
members
5/8" thick light textured
stucco on typical concrete
block construction
Varies - see plan
#5 bar vert. all
30' overlap
at each filled cell
Rear Patio/Slab to
be Plush with bottom of
sliding door recess.
Step per foundation plan
Slope per foundation plan °D
Batts
batts
'Frame ceiling transition
as needed using metal studs
field verifg exact configuration
and sizes
Drywall ceiling
see typical section
transition Insulation Detail
rite
0
Poured Cai
concrete h
Poured Concret
concrete block,
Concrete ,
Manufacture
chars Per
Specs
lax
Flush Mounted Shutter Detail
Aluminum Panel
Sims per manufacturer
— See Tumical Stud Detail
1/8" • 3/32' Wing Nut m/
appropriate washer and spacing
i per manufacturar's Details
o Oi3"
aA91'
A
I
Stud Detail
Stud w/ Die Cast Zinc NTa
Nickel Plated Wing Nut
nts
Brace Gable and
with 2" x 4" SYP #2
Slit back nailed to bottom
of top chords using (2) IOd
nails at each truss
RE -ENGINEERED WOOD TRUSSES
e 24"o.c. TYPICAL
! shop drawings by manufacturer )
a
� X
s_ �
a-s
�
N
Q 4L 7
a
0 ui
u ..
ti
O
°� 1Q dOD
EZ=
N
U V-
Q
sy
W
E#lc
Brace Gable and
with 2" x 4" SYP 42 min.
aft back nailed to bottom —
of top chords using (2) 10d
nails at each truss
2
c QUJ
\R-30 blown fiberglassin bottom chord oP trusses-1/2" drgmall with smooth finish o
Two rows of beam block filled with concrete
_and (1) #5 bar cont. in each row. Substitute
precast lintel Pilled with concrete and (U #5
bar cant. for bottom row over openings03
to
1/2" drywall over 1" x furring
strips at 16' o.c. with R4.1 ri-foil
-insulation on tgprcal 8" Block walls
Strap truss to wall
using Simpson
MGT with
Simpson
HETA 20
5/e dia.
threaded
rod with
min 12" embedment
hurricane anchor
at each truss
into beam
IOd
either wet set or in epoxg with
nails into truss. Add blocking to
( 2�" o.c.)
supporting Max.
pp 9
truss leg
per detail
on this sheet
META 20 1810
lbs. upllft
Milo
M
10
11150
AA
PAAN
WAN
M.
or
PA"I
ME
Ar
OWN M VAN "M A
aw.
OVA FFA
swum
Mir
"A
W
FM
Z.
10,
BENI
n
W
(Y
W
a
ti' X
� ss
+� Y-
U
'a c
(V
H�aa
n
_ �'w ui
U,:2
O R "
all p
R V_
v_ N
s
N
W
REVIEWED FOR
All drywall to be installed per FBC R102.3.1 ETA 20 CODE COMPLIA�_
i and shall meet all pertaining ASTM codes. W ST. LUCIE COUNT'
Mortar to be Type "M" only proportioned Der FBC RbOi.l
and Mortar joints shall comply with FBC R401.2.1.
Provide Dur-O-Rock at all wet areas (ax. showers, tubs etc...)1. B®CC
Fill cell with concrete and ROOF FLAN
(U #5 ppbar vert. (typicaD.
not
48x unlessnotherlwise noted exceed
Wage see Foundation plan notes for — OVERHANGS AT 1'-0" UNLESS OTHERWISE NOTED ON THIS SHEET
spacing at openings - #10/10 WWM on L and laROOF PITCH AT �f:12 UNLESS OTHERWISE NOTED ON THIS SHEET FILE Co
4" concrete slab with fp►y
L"xall Vissfiqueen over —
TRUSS SHOP DRAWINGS TO BE PROVIDED BY MANUFACTURER
L"
clean compacted termite treated Pill — ANY CHANGES TO THIS PLAN SHALL BE SUBMITTED TO THE
ARCHITECT FOR APPROVAL IN WRITING PRIOR TO STARTING CONSTRUCTION.
I— — ALL TRUSS TO TRUSS CONNECTIONS BY
'. L- III l TRUSS MANUFACTURER III
FI — ARCHITECT TO REVIEW TRUSS SHOP DRAWINGS PRIOR
I�III - TO CONSTRUCTION FOR LAYOUT AND UPLIFT VERIFICATION
ical Section at Front Porch — CONTRACTOR TO PROVIDE FOR FORM BOARD SURVEY AND TO PROVIDE
srale • I/')" = r—e)" FORM BOARD SURVEY TO TRUSS COMPANY PRIOR TO TRUSS CONSTRUCTION
1-2-19
I
PANEL
"All
Palo
BR
Load
Wme
Demiption
coca
cn $
Demgten
Wee
Lead
BR
Polee
1
20
1.2 km
#12
Rerrigereta
I
sL
12.0 km
50
2
1
20
1.2 ke
#12
Clothes Washer
3
1
20
13 km
#12
Kitchen S.A.C.
6
L
Drw
810
5.0 km
30
2
1
20
1.5 ke
#12
Kitchen S.A.G.
1
8
1
20
012
Bathroom Recepte
9
10
Air Cmdamor
910
5.0 ko
30
2
-
1
20
1.2 ke
#12
Dehme1w
II
12
1
20
1.2 km
#12
Mieraseve
13
14
Air H
$10
5.0 km
30
2
1
16
#14
Gonerd Lighting
16
IL
I
i6
#14
Generd Lighting
11
18
WH
#10
5.0 km
25
2
1
is
#H
General LighGns
141
20
1
r6
Of
Gonerd Lighting
21
22
GDO
012
0.81 Kill
20
1
1
16
#14
General Lighting
23
24
Spare
Spey
26
26
Span
Spare
21
28
Spero
swe
21
30
Sparo
PANEL "A" LOAD CALCULATION SHEET
Load Description
Ot .
Watts
Total(Watts)
General Llghtmg.(3,watts,ag it;) .........................
.90oll, Appliance_ Circuit(*) . .............. . .. . ..... . . ..... . . . .
,Range .................... ..
Rerrlgerator.....
Microwave .. .................... ...............
Dish Washer
.................................................................
,Clothes .Washer ...............................................
Clothe. ,Dryer ................................................
.Water. Heater .................................................
Garage.Door.Opensr........................................
1135
3
5.205
2
1,500
3,000
1
12000
12000
1
1,200
1,200
1
1$00
1,500
1
1200
1,200
1
1 00
I 00
1
5 000
5.000
I
4.500
4 500
1
810
810
Total Watts
35.LI5
First 10000 Watts e100%
I
110.000
IO 000
Remainder 25A15 940%
1
O
10.246
Electric Heat or A/C 10.000 065%
1
10.000
10.000
Calculated Load
Watts
30.246
Voltage
240
Calculated Wattage Divided by Voltage - Total Amps 12L.02
Panel Size Required = 150 Aia s
Electrical 5 mbol Legend
S
Sr ge Pole Switch
®
Recessed Can Light
Double Poke Switch
®
Egeball Recessed
a
Push Button Switch
0'
Exhaust Fan
ex Outlet
¢
Ce&q Moulted Light
Special Receptacle
♦
Wall Mounted Light
ground t mast
Light with Pull Chan (attic)
®
Floor Duplex Outlet
©
Cosiputer Connection Jack
®
Carbon Monoxide Detector
Flood Light
T
Thermostat
m
Electncol Panel
®
Central Vac
8
Electrical Meter
®
smoke Detector
Ceiling fan
®
Television Jack
❑Z
Telephone Jack
A Di a
A/C Disconnect
®
I x 4 Florescont Light
®
2 x 4 Florescent Light
®I
Speaker Hods -Up
= JUNCTION BOX TO SUPPORT A PAN
THERMOSTAT LOCATION
B/A = BALANCED AIR
Lent-thoL---
Soffit
1-2-19
FIELD VERIFY SERVICE LOCATION RESPECIVE
TO PANEL LOCATION AND USE
APPROPRIATE RISER BELOW
A/C disc.
A/C disc.
#2/0 AL SER Cable
(3) #1 THHN Copper
With #1 Grnd --------
2" PVC Schedule
40 conduit
2„ PVC Schedule
AC
40 conduit sleeve
50S
AMP
into attic
MCB
PANEL
AHU
PANEL
AHU
200a rated
200a rated
meter can
EE
meter can
ME ER
MQEE
R
Intersystem banding
Intersystem bonding
2" PVC ( FPL
Termination pant
2" PVC ( FPL
Termination pant
schedule 80
schedule 80
2' rimd service FPL
2" nind service FPL
rods
OPTIONAL
PATIO/SLAB
10 CFM
IOodOxL
MASTER
BEDROOM
its CFM
IOodoxt
4 %.21
B/A
CLOSE
- i ``•
ATH '�'
e e
10,
Meter 150 Amp
Panel
PATIO/SLAB
i
GR AT
RO M
I
I
OxdOx M I ,oneniteir cco ing ran steraIL41 C 1M
Al
1211
L- - - - - f -
MMME
r 22• x 54•
I AtWth Access f
L-----r
GARAGE
r----------------- i
I I
I I
I I
I I
I I
I I
I I
I I
I
I I
I I
DINING
ROOM
i � j I AIL•
232 CFM
12xix1
SECOND
BEDROOM
1 % j 12xl2x9
"1 B/A
COVERED
PORCH
ELECTRICAL RiSER ALTERNATE SERVICE ELECT. RISER
MECHANICAL L14YOUT
- Contractor shall use AL-CU Landing lugs. hiTS - Contractor shall use AL-CU Landing lugs. NT8
- Contractor shall torque lugs I.A.W. - Contractor shall torque lugs I.A.W. manufacturers recommendations which manufacturers recommendations which SCALE: 1/4" = 11 - O"
r 22• x 54•
I AtWth Access f
L-----r
GARAGE
r----------------- i
I I
I I
I I
I I
I I
I I
I I
I I
I
I I
I I
DINING
ROOM
i � j I AIL•
232 CFM
12xix1
SECOND
BEDROOM
1 % j 12xl2x9
"1 B/A
COVERED
PORCH
ELECTRICAL RiSER ALTERNATE SERVICE ELECT. RISER
MECHANICAL L14YOUT
- Contractor shall use AL-CU Landing lugs. hiTS - Contractor shall use AL-CU Landing lugs. NT8
- Contractor shall torque lugs I.A.W. - Contractor shall torque lugs I.A.W. manufacturers recommendations which manufacturers recommendations which SCALE: 1/4" = 11 - O"
shall be verified prior to construction
shall be verified prior to construction
- Verif AIC/KIC Rating prior to ordering equipment
- Verify AIC/KIC Rating prior to ordering equipment
ELECTRIC NOTES:
I.
Use copper wire only- Prom panel to devices
15. Contractor shall guarantee all materials and workmanship
free defects for a less than two from
20. All equipment and panel sizes shall be verified before
2.
Provide
and were all requirad smoke E Carbon
of period of not years
ordering. The contractor shall provide circuit routings to
Monoxide detectors.
the date or acceptance or certificate of occupancy. or one
suit the job conditions.
3.
Contractor to verify location of electrical
year from closing sale of house.
service and provider.
Correction of defects shall be completed without additional
21. Furnish and install all fixtures as called for on the plans
4.
ALL bath and kitchen receptacles to be GFCI
protected.
eherge and shall include replacements or repair of any
or as selected by others.
S.
ALL exterior outlets to be WP/GFCI protected
other phase of installation that may have been damaged.
L.
Recessed cans to be installed per NFPA requirements.
IL. It is not the intent of these plans to show every minor detail
22• All raceways and papas placed in or through any concrete
1.
Tamper resistant AFCI receptacles are required in
oP construction. The contractor shall furnish and install
slab shall be spaced a minimum of three diameters of the
ALL room&
all items for a complete electrical system and provide all
largest conduit or pipe from any other service.
S.
A/C Return Air Balance Must comply w/ FSC RMIL02
the requirements necessary for the equipment to be placed in
23. All below 9'-1' be
9.
%C Refrig��rLt Imes that are run thru slabs must be
a caved in G
proper working order.
exposed wire shall installed in metal EMT
conduit
10. ALL A/C Equipment shall comply with energy calculation 11. All work shall be done in accordance with the N.E.C. and
ll. All work shall be performed b a licensed electrical shall comply with all local codes and ordinances, and shall 24. Drger Vents to be installed per
R y most all standard requirements of the local electric utility FBIC RM1502
contractor, the completed system shall be Pulls operative. and telephone company.
12. Contractor shall pay for all Teaa, permits, testing, and
inspections including blower testing where required. 18. The electrical system shall be completely and effective)l
13. All work shall be coordinated with other trades to avoid grounded as required by the latest edition of the N.E.C.
interference with the progress of construction.
14. All required insurance shall be provided for protection 19. All material shall be new and shall bear underwriters'
against the public liability and property damage for the labels where applicable. 01 B
- rlurntinn nP r_6e! ninrlr
Exhaust Duct
Thru Soffit
4" Exhaust
Duct Thru
Wall
wP F
Install oulet
under diec.
not shown or U'
VH B clarity C
Vent- thru Q
Meter
OPTIONAL
PATIO/SLAB
i
overed Porc�i�\
MASTER
® BEDROOM WP GFCI
1
\ I
11 Irvi
J I
- - - e Smoke /Carbon G R A T
Monoxide Detector
Combo R 0 M
e r
®� I
S I
C
I
;FCI
' - - I
CL0SIE I ® II
I I iI E
I II
_ I I
m J I I
g 5---� GFCI i I DINING
,
I_ FC i I ROOM
GFCI GFCI
oF�FM e I
!I KITCHEN E)=
iL - - - - - - -- -
/2 F O
C.yM. Detector
R3141 FBC
GFc� 5a CN
•r
I / C
GF GFCI
42' GFCI
' r At Access I,. I F O Cente
Nth light
---� Lt �`�SEC01�I�5
150 Amy Optional f ► B,� 1)R O O M
Panel \ panecatoI l lo® S
Pull chain / \
fight in attic \�
M
42" GFCI
GARAGE / PS
Garage
Door /
Opener
I
WP GFCI
C O V ER Iio
I -I P'ORIC H f
ELECTRICAL PLAN
SCALE: 1/4" = 11-011
Post Light wth "l-.117n o
2309.1
Total Attic Space = 2124 sq. f t.
Venting Ratio 1/150 = 14.16 sq, ft. required
Provide A Continuous Vented Soffit
Photo cell
tiu
O
1
n
H.B.
Exhaust Duct
�Thru Soffit
Wire For
Front Post
Light
R
)DE t;( WillFLIIA13
T.
FILE Copy
raden t Braden AIA, PA
Wrine Building Corp.
Date Drawn
Revisions :
Sheet
Architects - Planners
-411 S.E. Coconut Avenue
The Grand Carlton
GARAGE
LEFT
3-25-20
Drawn by:
Tel : (112) 281-8258
C.C.U.
F. -
Fax : (112) 281-8283
E-mail: bradenaiaocomcast.net
Spanish Lakes
Checked by:
St_uwrt PL 'A4oIcI4 jtAAt 'nnnn,%o
St. Lucie County Florida
D.R.B.
OF 5
Comm #
12-2b
B