HomeMy WebLinkAboutProject InformationProject Summary o: Enfrigire House By. QUICK CALCS, INC. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946Phone:772-466-6799 Fax:772-466-6796 Email: QUICKCALCS@,AOL.COM Project For: THE GRAND CARLTON.IMPACT WYNNE DEVELOPMENT F.T. PIERCE, FL Notes: U� �� Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF :Inside.db 75 OF DesignTD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17848 Btuh Structure 17520 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent (O cfm) 0 Btuh Central:vent.(0 cfm) 0 Btuh none (none). Humidification 0 Btuh Blower 0 Btuh Piping' 0 Btuh Equipment load 23503 Btuh Use manufacturer's data n Rate/swing multiplies Equipment"sensible. 0.95 Infiltration load .24753 Btuh. Method Simplified Latent Cooling Equipment Load Sizing. Construction quality Average Fireplaces 0 Structure 3203 Btuh Ducts . 2318 Btuh Central vent.(O cfm) 0 Btuh Heatingg 9 Cooliegg (none). Area (f12) 14 1446 - Equipment latent load 5521 Btuh Volume (fP) 12511 125.11 Air changes/hour 0.45 .0.23 Equipment Total Load (Sen+Lat) 30274 Btuh Equiv AVF (cfm) 94 48 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling. Equipment Summary Make . Carrier Trade CARRIERAIR CONDITIONING Model 25HBC536A O30. AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 32 OF 8.5 HSPF 34600 Btuh @47°F 27 1160 o 0.049 cfm/Btuh 0.50 in H2O Backup: Input=.7 kW, Output=23009 Btuh,100AFUE Make Carrier Trade CARRIERAIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(BF)037 AHRI ref 79145.85 . Efficiency 12.0 EER,15 SEER Sensible cooling 24360 Btuh Latentcooling 10440 Btuh Total cooling . 34800 'Btuh Actual airflow 1160 cfm Airflowfactor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio . 0.83 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. ' ' 2020-Jao-081620:47 Ak^• n r „ RightSUL,@ Universal 201919.0.07 RSU08101 Page 1 ightsoftHVAm-rkE6RANDCARLTON-1446-IMPACT.np CaIc=MJ8 FrontDoortoes: N -� wrigh Right,J® Worksheet bate: Entire Dat House QUICK CALLS, INC. By. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466.6796 Email: QUICKCALCS@SOL.COM 1 Room name Entire House BEDROOM 2 . EVosed wall 1562 ft 49.0 ft 3 Room height 8.7 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 297.0 ft 5 Room area 1445.5 12 .297.0 iF Ty Construction U-value Or HTM Area (W) Load Area (W) Load number (BtuWF) (Btuh/IF) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13AAocs 0143 n 4.00, 2,55. 503 465 9862 - 1184 . 72 72 288 183. 4A5.2om 0:7Z0 i n 211%. 19:31 .. '38 ' .-CO 815 - ' "730 ' 0 _ , 0 to " :0 V�/ 13A�4ocs 0.143 a 4.00 2.55 128 83 M 212 0 0 0 0 1A-clom 1270 a 35.56 8729 24 2 848 2082 0 0 0 0 11 II_-G D 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W. ,13A 4oics . 0.143 . -se. 4.00. 2.55 r : .34 - 34 . 136 . `86 ' . 0 .0 .0. ;0 V�l 13A4ois 0.143 s 4.00 2.55 360 353 1414 899 216 216 865 550 L--G 1A-c1om 1270 s 35.56 34.77 7 7 247 241 0 0 0 0 13A as 0143 , w 4.00 2.55 310 237 ... 949 603 : ' :104 72 288 '183 G 1A c1om.:. 1270 : w'. -35" 5521 ; 32 2 1140 . 1770 : 32 '2 1140 17Z0 `.4A5-2om . . 0.710 w 2156 1931 41 41 880 788 0 0 0 0 ; P 12C-0sw 0.091 - 2.55 128 192 192 489 •246 0 0 0 0 C 16A-3t)md 0.032 - 0.90 2.32 1446 1446 1295. 3354 297 :297 266. 689 F 22A tpl ' 0.986 - 27.69 0.00 1446 156 4325 0 297 49 1357 0 6 c) AED excursion 918 627 Envelope losslgain 14961 13349 4204 4003 12 a) Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 13 Internal gairw. Occupants@ 230 6 1380 3 690 Appliances/other 2000 0 Subtotal(lines6to13) 17848 17520 5053 4925 Lessextemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 5053 4925 15 Ductloads 32% Q%l 5654 8536 32% 49% 1601 .2400 Total room load 23503 26056 6653 7325 Air required (dm) 1160 1160 ' 328 326 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. via- ? �! 2020-Jan-0816:20.47 t1GCA Pig"dte@)Uriversal 20l9 l. 9.0.07 RSU08101 Page 1 IgNsoftHVAC1THEGRAND CARLTON-1446-IMPACT.np Calc = MJ8. Front Door faces: N -� wrights Right-M Worksheet Job: Entire House D ate` By QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC KrrCHEN: 2 EVosedvall O ft O ft 3 Room height 8.0 ft heatl000l . 8.0 ft heaftol 4 Room dimensions 6.0 x 9.0 ft 1.0 x 172.0 ft 5 Room area 54.0 W 172.0 ftZ Ty Construction. U-value Or HTM Area Load s (ftZ) Load number (BWhtF--°� (Btuh/ft2) or perimeter (ft) (Btuh) Zr perimeter (ft) (131uh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 IQ 13A13ocs 0143 " n: 4.00 255 . 0 0 0 0 .: -0 0- 0 . : p 4A5-2om"-" 0 770 . n' ' 21.56 19.31 0 0 -0 .0 0 . '. . .0 0 0 1�1 13A-4as 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 �-G IA-c1om 1270 a 35.56 8729 0 0_ 0 0 0 0 0 0 11 D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W 13A-4ocs: 0143: "se. .4.00 . 2.55 .:0, 0 0 " 0 0.- 0 p 6 Y--G 13A4= 0143 s. 4.00 2.55 0 0 0 0" 0 0 0, 6 IA-dom 1270 s .35.56 34.77 0 0 0 0 0 0 0 0 13A oc 0143 w 4.00 2.55 0 0 0 0 0 0 : 0 0 G 1A c1om; '. 1270 w 35:56 55;21 0 :. 0: 0 0. :0' 0 0 0 4A5 2om'. . 0.776 w 21.66 " , 19.31 0 0 6 .6 ` 0 01 0 0 P 12,C-0sN 0.091 2.55 128 0 0 0 0 64 64 163 82 C . -16A-30rnd 0.032 - 0.90 2.32 54 54 . 48. 126 172 " 172 " " 164 399 .F 22A tpl 0.989 - 27.69 0.00 54 0 0 0 172 0 0 0 6 c) AED excursion -9 -170 znvelope loss/gain 48 117 317 311 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliance-Vother 01 2000 Subtotal (lines 6 to 13) 48 117 317 2311 Less exlemal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal" 48 117 317 2311 151 Duct loads 1 32% 49% 15. 57 32% 4.9%1 100 1126 Total room load 64 174 416 3437 Air required (dm) 3 8 21 153 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. 2020-Jarr081620.47 Right-Sdte® Uriversal 201919.0.07 RSU08101 A a h ...igt wt WACWHE GRAND CARLTON-1446-IMPACT.rtp Calc= W8 Front Doorfaces: N Page 2 IFF wdghtSOW Right-M Worksheet Dab. Entire House °ate' QUICK CALCS, INC. ay 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name BATH BEDROOM2 2 Exposed wall 5.0 ft 342 it 3 Room height 8.0 It heaNcool 8.0 ft headcool 4 Room dimensions 9D x . 5D . It 1.0. x 203B ft 5 Room area 45.0 tt2 203.5 ft2 Ty Construction U-value Or HTM Area . OF) Load Area . Load number (Btuhdk'F) (BtuhhV) or perimeter (ft) (Btuh) or perimeter (ft) (Bfuh) Heat Cool Gross N/P/S Heat Cool Gross NIPS Heat Cool 6 Val L--G 13A-Aas<.. 0143 n. 4.00 2.55 40 40 160 102 . 128 128 '513 --3,26, `,4A5 tom' 0.770 n - 21i56 19:31 p p 0 p • 0 ` ' 0 ... : 0 .. 0 13AAocs 0.143 a 4.00 2.55 .0 0 0 0 80 56 225 143 IA-c1om 1270 a 35.56 8729 0 0 0 0 24 2 848 2082 11 D 11DO 0.390 . e 10.92 11.31 0 0 0 0 0 0 0 0 W. , 13A..41ocs. 01.43 - 'se- 4.00 `2.55 .. % : - 0 - 0 . 0 34 34 136 86 �13A-4ocs 0143 s 4.00 2.55 0 - 0 0 0 32 32 128 81 G IA-c1om 1270 s 35.56 34.77 0 0 0 0 0 0 0 0. 0143 - vv 4.00 2.55 0 0 p p 0 .0 0 - O G 1A-clom 1270 •w 36.56 5521, 0':. 0 D- 0 0 0 0. 0 `4A5 tom .' 0.770 w 21.56 10.31 0 0'. 0 0 -6 0 0 0 P 12C-Osw 0.091 - 2.55 128 0 0 0 0 0 0 0 0 C , 16A-30md 0.032 - 0.90 2.32 45 45 40 104 . 204 204 . 182 472 F 22Frtpl 0.989 - 27.69 0.00 45 5 138 0 204 34 946 0 6 c) AED excursion -16 -85 Envelope losslgain 339 190 2978 3106 12 a) Infiltration 87 24 593 162 b) Room ventilation 0 0 0 0 13 Internal gains: Oocapanls@ 230 0 0 1 236 Applianosslother 0 0 Subtotal (lines 6 to 13) 425 214 3571.. 3498 Less exlemalload 0 0 0 0 Lesstrans(er 0 0 0 0 Redisiributlon 0 0 0 0 14 Subtotal 425 214 3571 3498 151 Dud loads 32% 49% 135 104 32% 49%1 1131 1704 Total room load '560 318 4702 5203, Air*uired(dm) 28 14 232 232 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. c wr8g1la softy A Right+Sute®Uriversal 201919.0.07 RSU08101 2020-Ja"8.1620.47 Page 3 ighlsoftHVAC1THEGRAND CARLTON-1446=IMPACT.rLp Calc=MJ8 Front Door faces: N -da- wrighbwW Right-M Worksheet Job; Entire House' pate: QUICK.CALCS, INC. By 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM 1 Room name LAUNDRY GREATIDINING 2 Bposed wall . 6.0 ' ft 47.0 ft 3 Room height 8D ft heaV000l 9.8 ft heaV000l 4 . Room dimensions 7.0 x .61) ft 1.0 x 526.0 ft 5 Room area 42D fF 526D P Ty Construction U-value Or HTM Area Load Area number (Bhih/ F) (BtuhfiF) or perimeter (ft) (fth) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat I Cool 6 13A4orsc 0143 • n 4.00 2.55 - 0 0, 0 0 255 277 860 552 4A5 2om.' . 0.770 h' 21t56: '19:31 . ; . 0 0 0 .0' ..38 .• . 0 .. 815 730 V)/ 13A4o s 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om 1270 a 35.56 8729 0 0 0 0 0 0 0 0 11 II-_G D. 11DO 0.390 a 10.92 11.31 0 0 -0 0 0 0 0 0 W.. - -13A-4ois. 0.143 se • 4.Q0 2.55 - 0 0 0 , 0 . 0 p . 0 0 t-G 13AAocs 0.143 s 4.00 2.55 48 48 192 122 0 0 0 0 1A-c1om 1270 s 35.56 34.77 0 0 0 0 D 0 0 0. i 2�6 1 420 1Ac1om 1270 w 35.56 5521 0 0 0 0 .0 0 0 0 0. 4A5 tom . 0. 0 w 21.56 19.31 0 0 .. 0 0 0 788 P 12C-Osw 0.091. - 2.55 128 56 56 143 72 0 0 0 0 C-; 16A 30md 0.032 - 0.90' 2.32 -42 42 38 . 97 526 ' 526 471 1220' F 22A ml 0.989 - 27.69 0.00 42 6 166 0. 526 47 1302 0 6 c)AEDexarsion -22 668 Envelope loss(gain 539 270 4997 4379 12 a) Infiltration 104 28 997 273 b) Room venfilatfon 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 2 460 Appliancedother 0 0 Subtotal(lines 6to13) 643 208 5994 5112 Lessexllemalload 0 b 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 6431 298 6994 5112 15 Duct loads 32% 49% 204 . 145 32% 49% 1899 2460 Total room load 846 443 7892 7602 Air required (cfm) 42 20 3901. 338 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. -�}.- wragrsor �.C.F► Rlght-Sute�el Universal 201919.0.07 RSU08101 2020-Jarr081620:47 Page 4 ...IgHsoftHVAC1THEGRAND CARLTON-1446-IMPACT.np Calc=W8 FrontDoorfaces: N - F Jove wrights� R'Iight-J® Worksheet Entire House Date: sr QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax 772A66-6796 Email: QUICKCALCS@,AOL.COM 1 Room name FOYER M BATH 2 7.0 ft 8.0 ft 3 .E)posedvval[ Room height 8.0 ft heaftol 8.0 ft heaftol " 4 5 Room dimensions . Room area, 1.0 x 50.0 ft 50.0 fF 7.0 x 8.0 ft 56.0 W Ty Construction number U-value (Btuhllf-°F) Or HTM (BIuW) Area - OF) or perimeter (ft) Load (Btuh) Area (tP) or perimeter (ft) Load (Bh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 .G 1D1A-clom 13A '4A5-tom ': 13A-4ors 0.143 0.770 0.143 o- . h a 400 21:56 4.00 2.55 ,' 19.31 2.55 8. p 48 8 0 27 " 32 0 108 20. ` 0 69 0 0 0 0 :.0 0 0 0 0 0. . 0. 0 1270 a 35.56 8729 0 0 0 0 0 0 0 0 11 11130 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W.- Vdl. 13A-4ocs,.. 13A-4ocs 0.143 0.143 se, s 4.00 4.00. :2.55 2.55 0 0 0 0 ..0 0 . 0 0 _ 0 64 0 57 0'. 228 0 146 IA-clom 1270 s 35.56 34.77 0 0 0 0 7 7 247 241 -a 13A flocs. 0143 ,w 4.00 0 0 0 . 0' 0 70 :0 0 1Aclorn.: 1270 w 35.56 55.21 0�. 0. 0 0 0 0-.0 �,o '4A5-26m 0.770 w 21.56 19.31 0. 0 0 .0 0 '0 0 0 p 12C-0sw 0.091 - 2.55 128 72 72 183 92 0 0 0 0 ,C . ;16A-30md 0.032 • - 0.90 2.32 50 50 45 116.. 56 56 50 130 F 22A-fit 0.989 27.69 0.00 50 7 194 0 56 8 222 0 6 c)AEDexarsion -39 -38 Envelope losdgain 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Applianoedother 0 0 Subtotal (lines 6 to 13) 913 529 885 516 Less exbemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 O 0 0 14 Subtotal 913 529 885 516 15 Dud loads 1 32% 49% 289 258 32% 49% 280 251 Total room load T1202 787 1166 768 Airrequired (dm) 59 35 58 34 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2020-Jan-081620:47 Riga-Srite®Urrversal 201919.0.07 RSU08101 Page 5 igMsottWACWHEGRAND CARLTON-1A46-1MPACT.n{� CaIc=MJB FrdrttDoor iaws: N -- wrightsoft® . Duct System Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phore:772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM eroject intormation For. THE GRAND CARLTON IMPACT WYNNE DEVELOPMENT, FT. PIERCE, FL Extemal static pressure Pressurelosses Available static pressure Supply/ return available pressure Lowestfriction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/10011 1160 ch 1.76 ft I Supply Branch Detail Table Job: Date: By- Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O -0.285 in/100ft 1160 cfm Name Design (Btuh) Htg (drn) Clg (drn) Design FR Diam (in) H x W (in) Duct Mail Actual Ln (ft) Ftg:Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 Ox 0 VIFx 22.4 115.0 st1 BEDROOM2 h 4702 232 232 0.360 7.0 Ox0 VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 0.300 6.0 Ox0 VIFx 31.8 135.0 st2 BEDROOWB h 3327 164 163 0.285 6.0 Ox 0 VIFx 40.6 135.0 st2 FOYER h 1202 59. 35 0.505 4.0 Ox 0 VIFx 4.0 95.0 GREATMINING h 3946 195 169 0.300 7.0 Ox 0 VIFx 31.8 135.0 st2 GREATIDINING-A h 3946 195 169 0.300 7.0 Ox 0 VIFx 31.8 135.0 st2 KrrCHEN C 3437 21 153 0.379 6.0 Ox 0 VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 Ox 0 VIFx 23.3 115.0 st1 M. BATH -A h 768 58 34 0 0 Ox 0 VIFx 0 0 WIC C 174 3 8 0.309 4.0 Ox0 VIFx 27.0 135.0 st2 Supply Trunk Detail Table 3 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (Cfm) FR. (fpm) (in) . (in) Material Trunk st2 PeakAVF 721 672 0.285 918 12.0 0 x 0 VinIFIX st1 st1 PeakAVF 1043 1091 0.285 1020 14.0 0 x 0 VinIFIX wrightsoft, 2020-Jan-081620:48 '�• nwuk•�wk.we�.rm.vmn.RigFdSLite®Uriversa1201919.0.07RSU08101 Page 1 IgHsoftFNAMTHEGRAND CARLTON-1446-IMPACT.np Calc=MJ8 FrordDooriaces: N Return Branch Detail Table Name Grille Size (in) Htg (cf n) Cig (cfm) TEL 00 Design FR . Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat Trunk rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 MR wrighltsofi- 2020-Jao-081620*48 14L. nw avennw.wm®.rro.v.� Rigtd-Sate® Uriversal 201919.0.07 RSU08101 Page 2 IgNsoft WAOTHE GRAND CARLTON-1446-IMPACT.rLp Calc=MJ8 FrotdDoorfaces: N