HomeMy WebLinkAboutProduct approvals, roof tiles gfj.�•' ; r:f:i;i".-4�•:..ate.. _ ::%'•!'.._.r::._. '. i: _ -i• ^��.:' -'�'{�-"�_:�`w::`-:arc;-..-_ti�a'n:� {s�? �;'i �.
a.•�:-�.• :.�:�M�-S'-'J�S},?�...a.=�C 1Y:'ir+?.�''y-'i:;s?Y:�.�.r�����`;_��:.�.:.::ii�•;:��1 '..��;i•^-'�.-.- `:c.^•�Y,.;
.y tr
.-'•�Y7'r...1 fir-7.1 ;�a -yr -r �a't•.•S r-•'a.:' -,'�•�N = _ _
n C•%' $�� .-.s':..f�•-1^•?�`�'.•;f..-i ,•rra �•.— k"'vi_ e' -iti
' F3'.y: •aV�„4'?:x:' �Ki:i'�-�:}`�Y i:X•�.���. .-ay�f.� •�.•S•sr a.�i�'S: .t.c_:J_�S .7��.,r - .0
%.om.�-r ��, s=+C.;:Kati.jt8.::.Et:w?'*'^ t.- _:=_+^:w :y.:.�� _ L� •=::f.....+„yt i - _
BCIS Home ? Log'In User RegLgmdon ` Hat Topics ': Submit Surdiarga Stats&Faas `: Pubriptions = FBC Start ! MS Sfte Map ' Unk seams `
rII1dda ..;.-
- Product Approval
<_ = USER:PuN IC user; r
yProduct Aooroval Mend>Prede or AOallratran S >earch Avollca an list>Applieatlan Oetall _
c
FL# FL7804-R10
Application Type Revision
Code Version 2017 WOOApplication Status Approved I ��
COpE C® �® U®R
Comments h
Archived S1'e LU PLIANCE
CIE.COuN7
Product Manufacturer Entegra Rolf Tile,LLC ®�
Address/Phone/Email 1289 NE 9th Avenue lc
Okeechobee,FL 34972
(602)51S-6933
thomasjemmett@boral.com
Authorized Signature Thomas Jemmett
thomasjemmett@boral.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Roofing Tiles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nleminen
the Evaluation Report
Florida License PE-59166
i Quality Assurance Entity PRI Construction Materials Technologies,LLC
° a Quality Assurance Contract Expiration Date 11/01/2018
Validated By John W.Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL7804 R10 COI 2016 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM C1492 2003
FRSA/TRI April 2012 2012
SSTD 11 1997
TAS 100 1995
TAS 101 1995
TAS 102 199b
TAS 102(A) 1995
TAS 112 - 1995
Equivalence of Product Standards
Certified By
I
http:[Avww,Roridabufding.org(pr/pi app dt1.aspx?param=wGEVXQwtDquovOjOFII%2bAMgsl79%2bkbgMWULRpAyR%2fQOg3lx7gHM6LOA°k3da/o3d 112
I
!
EXTERIOR RESEARCH&DESIGN,U.C.
Certlflcate of Authorization#9503
TRINITY ERD 353 CHRISTIA
OXFORD,�cr 6478
(203)262-9245
EVALUATION REPORT.
Entegra Roof Tile,LLC Evaluation Report E39310.=11-1-R4
C.NTEGFQA 1289 NE 9u'Avenue FL7804-R10
r--: Q'Co F T I L E Okeechobee,FL 34972 Date of Issuance:21/02/2611
(602)51S-6933 Revision 4:10/17/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6ei Edition (2017) Florida Building Code
(HVHZ)sections noted herein.
DESCRIPTION: Entegra Concrete Roof Tiles(HVHZ jurisdictions)
LABEUNG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPUANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Evaluation Report number preceded by the words`TrinityI ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
RobertJ.Nl.Nieminen P.E. %?oti�Q_^ ..ter mer2wmue:e�2PPea W3S4UthotZedbrnobenulcmmeI
• iii s�,���..-*,j ' P.Em10/17/IDD.Ws doesmt Serve as me[ectudea0y sl8reed
Florida Registration No.59166,f1aridaDCAANE1983 i.4,��V7.t��r� doament.signed.saledhudoPros ham
ecmuarumtttmtoihe
,�,lfi„s.attrt++s Product ApprovalAdroWstratarardtothetumedderd
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. j
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing productsjfor
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen,P.E.are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
i
i
i
i
I
I
i
i
TRINITY-ERD
ROOFING SYSTEM EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Roofing Tiles
Compliance Statement: Entegra Concrete Roof Tiles,as produced by Entegra Roof Tile, LLC, have demonstrated
compliance with the following sections of the Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section Property Standard Year
1523.65.2 Physical Properties TAS 112 1995
1523.65.2 Wind Driven Rain TAS 100 1995
1523.6.5.2.2 Static Uplift Resistance TAS 101 1995
1523.6S.2.3 Static Uplift Resistance TAS 102 1995
1523.65.2.3 Static Uplift Resistance TAS 102(A) 1995
3. REFERENCES:
Enter Examination Reference Date
ERD(TST6049) TAS 101 P39740.02.12 02/21/2012
ATL(TST3782) Physical Properties RT0624.05-14 07/03/2014
ATL(TST3782) Physical Properties RT0624.04-14 07/07/2014
ATL(TM782) Physical Properties RT1210.02-15 12/17/2015
ATL(TST3782) Physical Properties RT1210.03-15 12/17/2015
ATL(TST 3782) Physical Properties RT1103.01-15 11/07/2015
ATL(TST 3782) Physical Properties RT1103.02-15 11/07/2015
ATL(TST 3782) Physical Properties RT1103.03-15 11/07/2015
ATL(TST 3782) Physical Properties RT1103.04-15 11/07/2015
An(TST 3782) Physical Properties RT1103.05-15 11/07/2015
Miami-Dade(CER1592) HVHZ Compliance 24-0416.12 11/27/2024
Mlami-Dade(CER1592) HVHZ Compliance 15-0721.04 11/05/2015
Miami-Dade(CER1592) HVHZ Compliance 16-0112.06 02/25/2016
Miami-Dade(CER1592) HVHZ Compliance 16-0112.07 02/25/2016
Miami-Dade(CER1592) HVHZ Compliance 16-0112.08 02/25/2016
Tile Roof Institute TAS 100,TAS 101,102,102(A) Membership Confirmation Current
PRI(QUA9110) Quality Assurance Service Confirmation Exp.11/02/2018
Exterior Research and Design,LLC Evaluation Report E39330.11.11-1-R4
ccw1kate of Autherbadon"503 eEomoN(2(17)FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revislon 4:10/17/2017
Page 2 of 8
i
I
TRINITY Epp
5. LIMITATIoNs:
5.1 This is a building code evaluation. Neither Tr)nitVJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting FBC HVHZ requirements.
53 Fire classification is not part of this evaluation;refer to FBC M6 or listing by an approved testing agency for
fire rating of this product.
5.4 Reference is made to FBC 1512.4.2.4 regarding field testing of completed tile roof installations.
55 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests`in
accordance with TAS 112,Appendix W.
5.6 Minimum underlayment shall comply with the RAS 218,RAS 119 or RAS 170,as applicable. Underlayment
products shall hold current Florida Statewide Product Approval or Local Approval for use in file roof
assemblies in FBC HVHZ jurisdictions.
5.7 Minimum roof deck.requirements shall be in accordance with applicable FBC HVHZ requirements.
5.8 All products-in the roof assembly shall have quality assurance audit in accordance with the E.A.C. Rule
61620-3.
6. INSTALLATION:
6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar-set or adhesive-set. Installation shall
comply with manufacturer's current published instructions,but not less than the requirements of RAS A!8,
RAS 179 or RAS 120,as applicable.
6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment-Based System' In
accordance with Roofing Application Standard RAS 127-11 using the data outlined herein.
TABLE 1:AERODYNAmic MuLnPUERS-fir(F?)
Tile Batten Application Direct-Deck Application
Bermuda Fiat 0.189 0.205
Plantation Flat 0.267 0.289
Horizon Flat 0.305 0.330
Bella High 17 0.349 0378
Estate"S" 0.267 0.289
Hacienda 0.267 0-289
Galena Spanish"5" N/A
0.235
Regal 0.287 0.311
TABLE 2: RESTORING MOMENT DUE TO GRAVFTY Ma(FT-LBF)
Roof Slope(ej
Tile 2:12<0<3:12 3:12<0<4:12 4:12<0<5,12 5:12<0<6:12 6:12<8<7:12 0>7:12 1
Battens Direct Battens Direct Battens Direct Battens Otrect Battens Direct Battens Direct
Bermuda Flat 5.22 6.43 5.17 6.37 5.09 6.27 4.98 6.15 4.86 6.00 4.72 5.83
Plantation Flat 7.22 7.91 6.85 7.79 6.75 7.67 6.61 752 6.44 732 6.26 7.04
Horizon 7.60 8.32 752 8.24 7.41 8.12 7.26 795 7.09 7.76 6.89 755
Bella High"5" 6.19 6.89 6.11 6.80 599 6.67 5.85 6S1 5.68 6.33 550 6.13
Estate"s" 6.14 6.84 5.91 6.74 5.82 6.64 5.70 6.50 SSG 6.33 SAO 6.14
Hacienda 5.92 6.80 592 6.80 5.82 6.69 5.70 6S5 556 6.39 5.41 6.22
Galena Spanish"S" N/A 6.20 N/A 6.13 N/A 6.03 N/A 5.89 NIA 5.74 NjA 5.57
Regal 7.77 8.34 7.77 9.34 7.65 8.20 7.49 8.03 T30 7.83 7.10 7.61
Exterior Research and Design,CLG Evaluation Report E39310.11A11-R4
Cerd/lcatc of Aodwrlradon#9503 6"EDmON(2017)FBC HVHZ EVALUATION FL7804-RIO'
Entegre Roof Vies Revision 4:10117/2017!
Page 5of8
i
I
i
t
TRINITY ERD
4.2 TAS 112,Type 1a(interlocking,high-profile) BELLA Hint`IS"
0
1 n 13141"
Bella High 5
4.3 TAS 112,Type 1b(interlocking,low-profile). ESTATE"S"and HAaeNDA
Nail Holes
•
•
t3
Estate"S" Hacienda
4.3 TAS 112,Type 2a(non-interiocking,high-profile) GALENA SPANISH"S"and REGAL
1711
Galena Spanish"S" Regal
Exterior Research and Design,LLG Evaluation Report F39310.21.11-1-R4
Certf)7CW o ofauCAorfradan OSs03 EDITION 12017)FBC HVHZ EVAWATION FL7804-R10
Entegra Roof Tifes Revision 4:10/17/2017
Page 4 of 8
I
± I I
I
I •
TRINITY ERD
4. PRODUCT DESCRIPTION:
4.1 TAS i1Z,Type 3a(flat-profile) BMMUDA FLAT,PLANTAVON FLAT and HoRmoN FLAT '
10'
Y
L 16'
T-
2'
10•
I
Bermuda Flat Plantation Flat
Horizon Flat
f
Exterior Research and Design,LLC Evaluation Report E39310.11.11-1-R4
C-d/&aeeofAudjvAza on#9503 6'"EDAION(2017)RCHVH2EVALUATI04V FL7804-1110
Entegra Roof7iles Revision 4:20/17/2011
Page 3 of 8
I,
� 1
1 I
ER�TRINQTY:
and/or
Hanson
1
i
Labeling:Horizon Flat,Hacienda,Regal
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Plant Profiles
Okeechobee,FL Bermuda Flat,Plantation Flat,Estate"S",Bella High"S",Galena Spanish"S"
Ft.Myers,FL Horizon Hat,Hacienda
Deerfield Beach,FL I Horizon Flat,Hacienda,Regal
10. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies,LLC.—QUA9110;(813)621-5777
-END OF EVALUATION REPORT—
i
I
Exterior Research and Design,I.I.C. Evaluation Report E39310AL11--1-R4
&rtF/cww afAuthorhattaa H95= O'EDMON(2017)FBC HVHZ EVAIMATION FL7804-R10
Entegra Roof Tiles Revision 4:2 011 712 0 17
Page 8 of 8
{
i
l-RINJ ERD
TABLE 4:ATTAciiMENT REsisTAN[E EXPRESSED AS A MOMENT--MF(FT-LBF)
MORTAR AND ADHESNE-SET Symms _
Note from Entegra Roof Tile, LLC: The performance data listed in Table 4 are based on the respective adhesive manufacturers'test
reports and Miami-bode NOAs. Entegra Roof Tile,LLC relies upon the adhesive manufacturers to provide these values for our inclusion
In this FEC HVHZ Evaluation Report. Please consult the individual adhesive manufacturer for information on product approvals,
limitations,revisions or other information for determining wind load and overturning moment performance.
Tile Adhesive
Tile Product Product Approval Placement Mf(ft-lbf)
'TILE BOND`by Dow Chemical NOA 16-0222.01 Interdependent(2-paddy) 41
Bermuda 'Touch N'Seal Storm Bond"by DAP Foam NOA 16-0421.03 interdependent(2-paddy) 73
Flat, "Polyset°RTA-1"by ICP Adhesives&Sealants NOA 16-0315.03 interdependent(2-paddy) S2
Plantation 43
Flat or "Polyset0 AH-160"by ICP Adhesives& Interdependent{2-paddy)
Horizon Sealants NOA 17-0322.03 independent(medium paddy,—30 g) 51
independent(large paddy,—45 g) 92
'TILE BOND'""by Dow Chemical NOA 16-0222-01 Interdependent(2-paddy) 44 1
'Touch N'Seal Storm Bond"by DAP Foam NOA 16-0421.03 Interdependent(2-paddy) 42
Estate"S"or "Polyset°RTA-1"by ICP Adhesives&Sealants NOA 16-0315.03 interdependent(2-paddy) 44
Hacienda " Interdependent(2-paddy) 50 j
Polyseto AH-160�.by ICP Adhesives&
Sealants NOA 17-0322.03 Independent(medium paddy,—30 g) 37
Independent(large paddy,—54 g) 61
Mortar Various Per RAS 120 21
"TILE BOND"'by Dow Chemical NOA 16-0222.01 Interdependent(2-paddy) 48
'Touch N'Seal Storm Bond"by DAP Foam NOA 16-0421.03 Interdependent(2-paddy) 52
Bella High "Polyset°RTA-1"by ICP Adhesives&Sealants NOA 16-0315.03 interdependent{2-paddy) 36
"S",Galena
Spanish"S" "polyset°AH-160"by ICP Adhesives& interdependent{2-paddy) 30
or Regal Sealants NOA 17-0322-03 Independent(medium paddy,—30 g) 49
Independent(large paddy,-'63 g) 94 '
Mortar Various Per ITAS 120 25
7. LABELING:
7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo;as detailed
below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance
Agency noted herein.
and/or
E , ,\] n7l
Labeling:Bermuda Flat,Plantation Flat,Estate"S",Bella High"S",Galena Spanish"S"
i
Exterior Research and Design,I.I.C. Evaluation Report E39310.11.11-1-R4.
tgBfkvte ofAutharhadon#9503 6TM EDMON(2017)FBC HVHZ EVALUATION F1.7804-R10'
Entegra Roof Tiles Revision 4:10117/2017
Page 7 of 8
I .
TRINITY=ER®
TABLE 3A:ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT-MF(FT-l8F)
MECHANICALLY ATTACHED SYSTEMS
Fastener Direct-Deck Direct-Deck
(min.i5/3r (adn.19/ar
Tile Type # Size Shank Clip .plywood) plywood) Battens
Nail One(1) lad Smooth or Screw N/A 7.3 9.8 49
Nail Two(2) lad Smooth or Screw N/A 14.0 28.8 7A
Nail One(1) lad Smooth or Screw Eave 19.0 19.0 22.1
Nail One(1) lad Smooth or Screw Field 24.3 24.3 24.2
Bermuda Flat, Nail Two(2) lad Smooth or Screw Eave 319 319 32.2
Plantation Flat or Nail Two(2) lad Smooth orScrew Field 355 355 34.8
Horizon Nail Two(2) lad Ring N/A 30.9 38.1 17.2
Nail' Two lad' Ring' N/A 50.3' 6551 48.3'
Screw One(1) #8 N/A N/A 30.8 30.8 18.2
Screw Two(2) #8 N/A N/A 51.7 51.7 24.4
'installation with a 4-inch tile headiap and fasteners located min.2%-inch from head of tile.
Nail One(2)' lad Smooth or Screw N/A 8.8' 11.8' 4.1'
Nail Two(2) lad Smooth or Screw N/A 16.4 21.9 7.1
Nail One(1)2 lad Smooth or Screw Eave 19.02 19.0' 22.12'
Nail One(1)' lad Smooth or Screw Field 24.3' 243' 24.2'
Nail Two(2) lad Smooth or Screw Eave 31.9 31.9 32.2
Estate°5"or Hacienda Nail Two(2) lad Smooth or Screw Field 35.5 35.5 34.8
Nail Two(2) lad Ring N/A 27.8 37.4 28.8
Nail' Two(2)' 1& Ring' N/A 43.0' 67S' 5091
Screw One(W #8 N/A N/A 25.87 25.8' 22.9'
Screw Two(2) #8 N/A N/A 47.1 47.1 49.2
'Installation with a 4-inch file headiap and fasteners looted min.2%4nch from head of tile.
'For one(1)fastener installations,utilize hole that is approximately 4V.4nch from the interlocking edge.
Nail One(1) lad Smooth or5crew N/A 5.1 6.8 2.8
Nail Two(2) lad Smooth or Screw N/A 6.9 9.2 7.3
Nail One(1) lad Smooth or Screw Field 23.1 23.1 19.0
Nail One(1) lad Smooth or Screw Eave 29.3 29.3 24.0
Nail Two 12) lad Smooth or Screw Feld 27.6 27.6 38.6
Spanish'S'Bella Highr Regal Galena Nail Two(2) lad Smooth or Screw Eave 3&1 38.1 41.8
o or
Nail Two(2) Sad Ring N/A 28.6 41.2 19.4
Nail' Two(2)' lad' Ring' N/A 331' 48.1' 50.91
Screw One(1) 118 N/A N/A 20.7 20.7 18.1
Screw Two(2) #8 N/A N/A 43.2 431 29.8
'Installation with a 4-inch file headlap and fasteners looted min.2Y Inch from head of tile.
I
i
Exterlor Research and Design,LLC. Evaluation Report E39310.11.11-1-R4
CertlflcaW of Audyarkatka!l95= dm EDITION(2017)FBC HVHZ EVALUATION FL7804-1110
Entegra Roof Tiles Revision 4:10/17/2017
Page 6 of 8
f .