Loading...
HomeMy WebLinkAboutProduct information Po d--y EXTERIOR RESEARCH&DESIGN,LLC.I REVIEWED OR Z�353 CHRISTiAN STREET,flcute DNIT#13 ? �V a'' Co®E Cp�P p� OXFORD,Cr os478 STo L 9 aCIE ���g V C� PHONE:(203)262-9245 V CouN7y FAX:(203)262-9243 EVALUATION REPORT Bonn � 7 East Coast Metals,inc. Evaluation Report E10240A8.08-R4 2-301 West 8 Lane FL5374414 Hialeah,FL 33010 Date of Issuance:09/03/2008 Revision 4:03/17/2= SCOPE: This Evaluation Report is issued -under Rule 61GZO-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition(2014)Florida Building Code sections noted herein. DESCRIPTION: East Coast Metals Channel Metals LABEupNG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CormNuEo CoMPuANce: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in advertising literature. if any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION:upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection atthe job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: �'' '�"�-�•��� Thoualm3aseataRpflensiWAomedbyRobertNteminrn. -J�,'.. T..�? Robert].M.Hieminen P.E. ,s�,-.:_.:sic•r_�•' pE an�/i?/2D�S Thltdecscm2xtveosanelerco�lea9�tis- Flodda Registration No.59166,Rorida DCA ANE1983 :''a f�of f rt�,;� d+mtmL r%r4d.&ezkdhudmFk&hmbetntramwittediothe amdVC1AR rs M Admbdnraterxtd to the mmed cunt CERTIFICATION OF INDEPerIDENcE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire,a financial"interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD,is not owned,operated or controlled by any company manufacturing or distributing products It evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E.are,in anyway,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. i y[:RevieW:edFo de Coce n&Sh, ,k& 01/22/ i _. Tjs $ E is ' �� ROOFING COMPONENT EVALUATION: L SCOPE: Product Category: Roofing Sub-Category: Roofing Accessories that are an Integral Part of the Roofing System Compliance Statement: East Coast Metals Channel Metals,as produced by East Coast Metals,have demonstrated compliance with the following sections of the Florida Building Code through testing In accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. . 2. STANDARDS: Section Property Standard Year 1507.3.7 InstaUation,non-HVHZ FRSA/TRI April 2012(0412) 2012 1518.8.1 Installation,HVHZ RAS 118,119&120 1995 1523.652-2 Static Uplift Resistance TAS 201 1995 1711Z1 Static Uplift Resistance SBCCI SSM 11 1997 3. REFERENCES: Entltv Examination Reference Date ERD(TST6049) Static Uplift Resistance E42730.08?3 08/23/2013 ERD(TST6049) Static UPUftResistance ECM-SC679S12.14-1 02/37/2015 ERD P-ST6049) Static Uplift Resistance ECtvi-SC6795.12.1412 02/27/2015 Florida TEC USM93) TAS 101 SIO.62SR 10/27/2020 FRI(TSTS878) TAS 201 ECM-001-02-01 09/21/2001 PRI(TST5878) TAS 201 ECM-003-02-01 06/13/2005 PRI(=878) TAS 101 ECivi-004-02-01 06/13/2008 PRI(T5T5878) TAS 101 ECM-005-02-01 06/13/2008 PRI(7195878) TAS 101 ECM-006.02-01 06/13/2008 PRI(TS15878) TAS 101 ECM-007-02-01 06/23/2008 PRI(TSF5878) TAS 101 ECM-008.02-01 06/13/200B Florida Building Cade AttachmentRequirements FRSA/TRIA I-2013-(04-13 04 2 Florida Building Code-HVHZ Attachment Requirements RAS118 and 120 -._ 1995 East Coast Metals Metal Quality MIWerdfications Various Architectural Testing(QUA1844) Quality Control artiopation Letter Exp.12/31/20ia 4. PRODUCT DESCRIPTION: 4.1 Hip & Ridge Channel Metal: Pre-farmed metal cha el designed for use as a hip and ridge base to which roo iles are bonded in FBC Approved roof file adhesive. Hip&Ridge Channel Metal is available in 119-3/ -inch L 3/8-inch)length by 25,3,3.5,4,S.6 or 7-inch + /8-1nch) heights with 1.5-inch L 1/16-inch)deck-flanges. r rr I I Exterior Research and Design,t1G Evaluation Report E10240.08.OS-R4 CerN/lmta efAutharkad=09503 PM374-PA Revision 4:03/17/202S Page 2 of 7 I I i I I TMNI ERD 4.2 Trim Lock Channel Metal: Pre-formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof the adhesive. Trim Lock Channel Metal is characterized by its profiled and perforated upper horizontal flange designed to receive and allow for interlock with the overlying the adhesive. Trim Lock Channel Metal is available in IV-3/8-Inch L 3/8")length by 3,3.5,4,5 or 64nch(+3/8-inch)heights with 1.5-inch(±1/16-inch)deck-flanges. 4.2 Trim Lock Plus Channel Metal:Pre-formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof file adhesive. Trim Lock ;::,j'! Plus Channel Metal is characterized by its profiled and perforated upper horizontal flange designed to receive and allow for interlock with the overlying the adhesive and its perforated deck flanges, designed for Installation atop the roof underlayment via placement in FBC ��_ Approved roof tie adhesive, which flows-through and interlocks with the underlying adhesive. Trim Lock Plus Channel Metal is available in M 3J8-inch (t 3/8")length by 3,3.5,4,5 or 64nch(±3/8-inch)heights with 1.5-inch(±1/16-inch)deck-flanges. r 4.4 East Coast Metals Channel Metals are fabricated of the following metals: i • Galvanized Steel: Min.0.019+0.002-inch,ASTM A653(G-90),min.33 KSI. • Galvaiume Steel: Min.0.019+0.002-inch,ASTM A792,AZ55,min.35 KSi. • Aluminum: Min.0.032±0.002-inch,ASTM 9209,3003-H74,min.21 KSL D Stainless Steel: Min.0.019+0.002-inch,ASTM A240/A480,T304,min.35 K51. 5. WrmnoNs: 5.1 This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. I Exterior Research and Design,LLG Evaluation Report E10240.08.08-R4 Catllir W UfAurharrrarran 09503 F1S374-R4 Revision 4:03/1712015 r Page3 of 7 I i i I - . I I' Tryrypppry���pryp6 pp� ppqqp TY ERL.-r{��{,,''qq�� 5.2 FOR HVHZ4URiSDiQ1ONS: 5.2.1 For Hip &Ridge Channel Metal or Trim lock Channel Metal, refer to FBC RAS 118,Drawing 13, Detail 3;RAS M, Drawing 12, Detail 3; or RAS 120,Drawing 15, Detail 3. For Trim Lock Plus Channel Metal,refer to the installation Instructions herein. 5.12 For HVHZ jurisdictions,installations of Hip&Ridge Channel Metal and Trim Lock are prescriptive by RAS 118,119 and 120,and the data in Tables 1A and IB is supplemental to these prescriptive allowances. installations of Trim Lock Plus are limited to projects having a required moment resistance(Mr)or uplift resistance(F,), as determined in accordance with RAS 127,net greater than the following values. Referto the the adhesive manufacturer's published installation instructions for adhesive paddy placement details. Y `INDEPENDENT"paddy placement means each individual ble is bonded to the Channel Metal in its own,single foam paddy; tile head laps are not bonded. This method is limited to 2-part tile adhesives. Allowable performance data below for"INDEPENDENT"paddy placement already has a 2 to 1 margin of safety applied to ultimate performance. D "INTERDEPENDENT"paddy placement means each individual the is bonded to the Channel Metal in a foam paddy, and a second foam paddy bonds the tile head lap,or two tiles are bonded to the Channel Metal using a single foam paddy. Allowable performance data below for`INTERDEPENDENT'paddy placement already has a 4 to 1 margin of safety applied to ultimate performance. TABLE 1A:PERFoRMANcE UMrrAtloNs-HVHZ,INDEPENDENT PADDY PLACEMENT (2701 MMGINOFSAWYALRFWYAP➢UM) HipiAldge Metal Adhesive Allowable Performance. Design Metal Type Tile Type Placement Moment Based UpliftBased� Mi(ft Ibf) F(Ihf) Hip&Ridge day or 3M"2 Component Foam Inde Channel Metal ga OQed concrete Roofriile Adhesive AH160 Pendent 127 169 Trim Lock galvanized,Garvalumea, day or 3M—2-Component Foam Independent 172 159 aluminum or stainless steel concrete I RoofTile Adhesive AH-190 Trim Lock Plus galvanized,Gatvalumeo, day or 3M"'2-Component Foam Independent 177 16s aluminum orstafnlesssteel concrete I RoofTlte Adhesive AH-160 TABLEIB:PERFORMANtELIMrrAitoNs-HVHZINiemEPENDENTPADDYPLACEMENi (4To1MARGINOFSA MALRERDYAFFUW) Hip(Rldge Metal Adhesive Allowable Performance Tile Moment Based Uplift Based Design Metal Type Type Placement Mr(ft lbl) F'(Ibf) Trim Lock or Trim galvanized,Galvalumeo, day or 3W 2-Component Foam interdependent 95 88 Lock Plus aluminum or stainless steel concrete Roof Tile Adhesive AH-160 Trim Lock galvanized,Galratumea, dayor 3M"'Roof Tile Adhesive interdependent 99 94 stainless steel concrete RTA 1 Trim Lock aluminum dayor 3M"'Foam Roof71le Interdependent 90 84 concrete Adhesive RTA-1 Trim Lode Plus galvanized,Gaivalumea, day or 3M"'Foam Roof Tile Interdependent 90 84 aluminum or stainless steel concrete AdhesiveRTA-1 galvanized,Galvatumea or clay or TiLE BONDA1 Roof Tile Trim Lock stainless steel concrete Adhesive Interdependent 123 117 d Trim Lock aluminum ay or TILE BOND-Roof We concrete Adhesive interdependent 79 73 Trim Lock Plus galvanized,Galvalumea, dayor 71LE BOND"'Roof Tile aluminum or stainless steel concrete Adhesive interdependent 79 73 galvanized,Galvalume"or day or Touch'n Seat StormBond Trim Lock stainless steel concrete Roof Tile Adhesive Interdependent id6 139 dayor Touch'n Seal 5tormBond Trim Lack Aluminum concrete Roof Tile Adhesive Interdependent 58 54 galvanized,Galvalumea, day or Touch'n Seal StormBond Trim Lock Plus aluminum orstainlesssteel concrete Roof Tile Adhesive interdependent 58 54 Exterlar Research and Design,LLC. Evaluation Report E20240.08.08-R4 Certificate otAuthorlmtran 119503 • F1S374-R4 Revision 4:03117/201S Page 4 of 7 i i ,l i RINIW ERD 5.3 FOR NON-HVHZJURiSDiCTIONS: S3.1 For Hip&Ridge Channel Metal or Trim Lock Channel Metal,refer to FRSA/TRI April 2012(04-12). For Trim Lock Plus Channel Metal,referto the installation instructions herein 5-3-2 For non-HVHZ,installations are limited to projects having hip and ridge design pressure requirements,determined In accordance with Table 3A'of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the file adhesive manufacturets published installation instructions for adhesive paddy placement details. > "INDEPENDENT'paddy placement means each individual file is bonded to the Channel Metal In its own,single foam paddy,tile head laps are not bonded. This method is limited to 2-part tile adhesives. This method is limited to 2-part tile adhesives. Allowable performance data below for"INDEPENDENT"paddy placement already has a;2 to 1 margin of safety applied to ultimate performance. > "INTERDEPENDENT"paddy placement means each individual file is bonded to the Channel Metal in a foam paddy, and a second foam paddy bonds the file head lap,or two tiles are bonded to the Channel Metal using a single foam paddy- Allowable performance data below for"INTERDEPENDENT'paddy placement already has a 4 to 1 margin of safety applied to ultimate performance. TABLE2A:PamRMANcEUMirAnoNs-1110N-HVHZ,INDEPENDBrrPADDYPLACEmmT (Z To 1 WaGlN oFs4FETrA[RFADYAPPLlE7)) Hip/Ridge Metal Adhesive Allowable Uplift Design Metal Type Tate Type Placement Ipst] Hip&Ridge day or 3M1 2-Component Foam Roof Channel Metal galvanized concrete Tile Adhesive AH-1 So Independent 169 Trim Lodc galvanized,Galvalume°,aluminum or day or 3M"'2-Component Foam Roof Independent 173 stainless steel concrete Tile AdhesiveAH260 Trim Lack Plus galvanized,Gaivalume',aluminum or day or 3M"2-Component Foam Roof Independent 178 stainless steel concrete Tile Adhesive AH 260 TABtE28:PERFORMANCE LIMrrATioNs—No"VHZ,INrewsENDSNTPADDYPLAamiNT (4701 MARGW OFSAFETYALRLADYAPPLIED) Hip/Ridge Metal Adhesive Allowable Uplift Design Metallype Tile Type Placement (Psfl Trim Lock or Trim galvanized,Galvalume,aluminum or day or 3M"'2-Component Foam Roof Lock Plus stainless steel concrete Tile Adhesive AH-160 Interdependent 98 Trim Lock galvanized,Galvalume=or stainless day or 3M"'Foam RoofTle Adhesive Interdependent 110 steel concrete RTA 1 Trim Lock aluminum day or 3M"'Foam RoofTHeAdhesive Interdependent 93 concrete RTA 1 Trim Lock Plus galvanized,GalvalumeF aluminum or day or 3M"'Foam RoofTRe Adhesive Interdependent 93 stainless steel concrete RTA-1 Trim Lock galvanized,Galvalumea orstainless day or TILE BOND-RaofTdeAdhesive Interdependent 252 steel concrete Trim Lock aluminum day or TILE BOND"'Roof Tile Adhesive Interdependent 82 concrete Trim Lock Plus galvanized,Gaivalume9,aluminum or day or TILE BOND"'Roof rite Adhesive Interdependent 82 stainless steel concrete galvanized,Galvalumes or stainless clay or Touch'n Seal StormBond Roof Trim Lock steel concrete lileAdhesive interdependent 248 day or Touch'n Seal StormBond Roof Trim Lock Aluminum interdependent 61 concrete Tile Adhesive galvanized,Galvalume°,aluminum or day or Tcuch'n Seal StormBond Roof Trim Lock Plus interdependent 61 stairess steel concrete Tile Adhesive i Exterlar Research and Design,LLC. Evaluation Report E10240.08.08-114 CerW W o Authodwdon A9503 F1.5374-R4 f , Revislon 4:03/17/2015 -•-• --•-- - Page 5 of.7- i i crPIJI�JT-Y ER'D S. INSTALLATION: C 6.2 The roof deck shall be minimum 15/32-inch plywood(non-HVHZ)or minimum 19/32-inch plywood(HVHZ)attached in accordance with FBC Chapter 23 to the satisfaction of the AHJ. 6.2 Hip&Ridge Channel Metal and Trim Lock Channel Metal shall be Installed using min.12 ga.x 1Y4mch long x 3/8-1nch head diameter galvanized annular ring shank nails spaced 6-inch o.c along both deck-flanges. Fasteners shall, be positioned Y-lnch from the outside edge of each deck-flange,set in a bed plastic roof cement. For FBC HVHZ,refer to FBC RAS 118,Drawing 13,Detail 3;RAS 119,Drawing 12,Detail 3;or RAS 120,Drawing 15,Detail 3. 6.3 Trim Lock Plus Channel Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons of file adhesive centered beneath each 1S-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet adhesive and allow it to set-up prior to installation of roof tiles. tWUY View of Polyset AH160 PlacementforTrfm Lack Plus Channel Metal Installation 6.3.1 It is critical that the bond between the Trim Lock Plus Channel Metal,the the adhesive and the underlayment is not disturbed prior to or during placement of the ridge tiles. 6.3.2 Approved underlayments are the codified'30/90'system or other FBC Approved roof underlayments listing approved use of the subject the adhesive. extarlor Research and Design,LLG Evaluation Report E10240.08.08 R4 [erdlicare olAudwrltadan asso3 EL5374-R4 Revision 4:03/17/2M ?age 6 of 7 i i TRINITY ERD 6.4 Tile shall be installed atop the Channel Metal in accordance with the tie adhesive manufacturer's Approved,published installation instructions,subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed arid pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRi April 2012(04-12)or RAS 118,RAS 119,RAS 120 requirements. ,. Hip/Ridge Tile r --.. � '�� Tile Adhesive •'._, Trim Lock Plus 'a Mortar or Weather Block Adhesive I Tile Adhesive ��:::��� /ram \ •`s.•' View of Trim Loc(c Plus Channel Metal installation after Weather Blocked 6.4.1 Channel Metal shall be free of dust,debris,oils or other bond-breaking substance prior to placement of adhesive. 7. BUILDING PERMrr REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.' 8. MANUFACrURiNG PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C-Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE Emm: Architectural Testing,Inc —QUA1844,(717)764-7700 -END OF EVALUATION REPORT- Exterior Research and Design,u.0 Evaluation Report E1o240.08.08-114 CerdPxte of Antharkadva a9503 FL5374-R4 Revision 4:03/17/2015 Page 7 of 7 I I I y i i I i µ RN %0" , ERD EXTERIOR RESEARCH&.DESIGN,LLC. FL CERTIFICATE OF AUTHORIZATION V9503 September 6, 2017 RE: East Coast Metals, inc. East Coat Metals Channel Metalc 6`' Edition (201 7) F BC HVFIZ Affirmation of FL5374-R4 To Whom It May Concern: This letter serves to document that we have reviewed Florida Product Approval File No. FL5374-R4, and the Evaluation Report which forms the basis thereof,with respect to the 6`h Edition (2017)Florida Building Code, High Velocity Hurricane Zone sections set forth in Section 2 of our Evaluation Report. There are no changes to the Code that affect the Evaluation Report, and we have authorized the applicant, East Coast Metals, Inc.,to document compliance with the 6`h Edition (2017) Florida Building Code, HVHZ through the Affirmation Process. Please contact our Connecticut office with any questions. Respectfully submitted, Robert Nieminen, P.E. Vice President Florida Reg. No.59166 robertnieminen@trinityerd.com CERTIFICATION OF INDEPENDENCE: 1. Trinity ERD does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building:code evaluation. Neither Trinity ERD nor Robert Nieminen,P.E.are,in anyway,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. BUILDING SCiE'NCE RESEARCH y DESiC31N CONSULTATION MAIN OFFICE: 80'YESLER WAY.SUITE 200 1 SEATTLE, WA 98104 1 TEL: 206 467 0054 1 FAX:206 267 0267 CONNECTICUT: 353 CHRISTIIAN STREET, UNIT 13 1 OXFORD, CT 06478 1 TEL: 203 262 9645 1 FAX: 203 262 9243 LABORATORY: 10 MALONEY COURT I COLUMBIA, SC 29201 1 TEL: 803 988 8133 1 FAX:803 988 81 1 1 i