Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Truss
- e: A=LIFE SAFETY WARNING This symbol identifies Life Safety Warnings that should be read given special attention by all persons installing trusses. ry� it SPAGING NOTE jALL TRUSSES ARE TO BE SET AT 2'-0ON CENTER EXCEPT AS NOTED MULTIPLE PLY TRUSSES MUST BE ASTENED TOGETHER PER ENGINEERING BEFORE SETTING. REFER TO ENGINE ERING DRAWING TO DETERMINE A IF MULTIPLE PLY. A DON'T LIFT TRUSSES WITH SPANS LONGER THAN 30' BY THE PEAK. CONSULT BCSI 30' Span or less 30' to 60' Span so' degrees Spree er Bar Cr less -- /2�._APprox 2/3 to.-� a9 Line Sp4n opprox. Line 7/2 of Span REFER TO BCSI REFER TO BCSI Truss must be set this way if crone used Truss must be set this way if crone used. Truss is an example, your truss may not match This is an example, truss may not match. Insist crone operator setstruss this way. Insist crone operator sets truss this way. Al F 1AN [�LER NO T� UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT s WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS, CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR. U REPRESENTS A MANGER Ca SEAT PLATES BY CHAMBERS ill INDICATES LOAD BEARING WALL REQUIRED BY TRUSSES SUPPLIED BY BUILDER AT A HEIGHT OF 8'-1" ABOVE FINISHED FLOOR 12 4.00 r— upset=1/4" heel=315/16" PLUMB CUT END 1' 2 x 4 Top Chord WALL HEIGHT 8'-1" TYPICAL END DETAIL 12 4.00 F— 12 2.00 8$ —1 — (P1 upset=1/4" heel=315/16" PLUMB CUT END 1' " 2 x 4 Top Chord WALL HEIGHT 8'-1", END DETAIL: A ARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR'OF 17' Do not stamo.1 on trusses until they are braced r)er BCSI & properly nailed to straps & hangers 34 14' 20' GARAGE LEFT The Arahltect'p or Architect's reproeentative's shop drawing approval Is NOT.a "double check" of the contractor. The contractor shall remain responsible for checking field measurements and other construction criteria. Architect's N ■ approvalposers , l roof shape, review of truss 'trapping, and loading on ENGTH structure from gravity and uplift loads and their res "01 Q PAO 20110 %® -----------------------------------__-___-_______-_________-_____ 101 1010 ��� FA I 1poozolww_plm�p ` %® IIIIIIIIIIIIIEM Fdolo IIIN Is 00110, One 11101 10e��N ®_' Most, �, P00, ®\'_ % �. IPA •— 18411 0010, 100010 Is - %1 �' 7mzrzzopio4o0 ®1 j /ImIIlimimimmimE1 l-1■Ili I� 1� i QII' ////////////////// ���FAR 9,-6" T-4" true iocat, In , -- _ Approved Sy:__. Date r3raden8 Sraden AJ. .A. FABRICATION AGREEMENT TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED The legal description of the property where the trusses will be Installed is: The undersigned acknowledges and egreea; i Is the$ will ut made in sarm accordance with this truss placement diagram layout, whrchls the sole authority for determiningsuccesstul tabdcation of the trusses, 2-All dimensions In this layout have been verified by the undersigned, .3. Unless written notice Is provided by certified mall to Chambers Truss within tan (10) days of delivery the undersigned agree, that no backcharges will be allowed. In the event such written notice Is furnished Chambers Truss shell have three (3) bu noes days In which to begin repalm required, or to subsllhrle, other trusses, at Chambers option.' 4. The undersigned acknowledges receipt of "SCSI 1-03" summary sheet by'TPI & WTCA, 8. Delivery la to Job alto. It Is the buyers'responsiblihy to make the Job site suitable for delvery. Chambers Truss has the sole authority to determine the suitability of the job site or a portion ofthe Job she for dativeCh ry, smbem Truss will be responsible for dump delivery only, The buyer Is responsible for additional delivery expenses if Chambers Truss has to redeliver bemuse -job she la not prepared for delivery or buyer Is not prepared for delivery of trusses. Buyer Is responsible to Chambers Tress for towing cost$ due to site conditions, 8. Price as shown Iq paragraph 7 below Is subject to change If any changes are, made In this. layout A $50 per hour fee for revisions may be charged by Chambers Truss, 7: This is a PURCHASE ORDER to Chambers, Truss of the sum agreed to, or It ntj; agreement a reasonable price. Invoice will be made on delivery and paid whhin terms of net on delivery. Involve may. be made at scheduled date of delivery IT buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambere.Truss reasonable attorneys fee for collections In event of payment not timely made. 1.12 % per month so rv)ce ' charge will be added for all sums not Paid within terms. . 8, Signature or Initials anywhere on this sheet constitutes agreement to all terms herein. 9, In consideration of Chambers Truss extending credit for this material the undersigned ' unconditionally guarantees payment when due of any and all Indebtedness owed to Chambers Truss III entity mwmng material and the undersigned agrees to pay such Indebtedness Including attpmeys fees, If default In payment for material be made by the recipient.- `• 10. In the event of any litigation concerning this agreement, the items furnished hereunder or payments referred to herein, the. parties agree that the sple venue for any such action will be Saint Lucls County, Florida, 11. Design responsibilities are per "National Standard And Recommended Guidelines On Responsibilities For Construction Using Metal Plate Connected Wood Trusses ANSVMI/WTCA 4 - 2002 DATED -.. SIGNED , FOR TITLE" Aspreader ba►maybe reggbed por"BCSI 1-03" to prompt hiL ry & damge. Multiple ply trusses must be fastened togethar per engineering before they are set, failure to do so can result In roof collapse. Temporary and permanent bracing are required and can save life and property and is the responsibility of the truss erector. Study the contents of the Information packet Included on delivery before setting trusses. Trusses must ba setand braced pegdesign topleventilury G damage. Trusses must be set plumb and square Do notset bunks or stack of plywood, roofing material or any 1 other concentrated loads on trusses, this can cause collapse. DO'NOT SET TRUSSES USING THIS LAYOUT ! USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES j CHAMBERS TRUSS INC /�,/ A �\ 3106 Oleander Avenue Fort Pierce; Florida 34982-8423 800-551-5932 . fort Pierce 772.465.2012 Fax 779-465-8711 Vero Beach 772-569.2012 Stuart 772-2863302 ' 92.0/93.2 MITEK 4.2 DESIGN CRITERIA County SAINT LUCIE Building Department SAINT LUCIE COUNTY 1Z Wind Design Criteria ASCE 7-2010 C)l Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-10 p Roofing Material Shingle or Shake ,. r6 � o% °� N Loading in PSF Roof R.D.L. H a Top Chord Live 20 �ITop Chord Dead 7 4.2 Bottom Chord Live 10 Non -Concurrent �JI 3 I Bottom Chord Dead 10 3 v H TOTAL Load 37 7.2 o 1"1 Duration Factor 1.25 la Wind Speed 165mph H LA Top Chord C.B. Sheeting by builder. Bottom Chord C.B. Sheeting by builder. Highest Mean Height 14'1 Building Type ENCLOSED Building Category Il:Non Restrictive Exposure Category C Barrier Island No Conforms to FBC 2017 R.D.L.=Restrainin Dead Load C.B.=Continuous Bracing Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of the Buildin Desi per and/or Engineer of Record. Chambers Truss Inc. Drawing Name: M11323 I� Scale: 1 /4 = 1' 72 total trusses, 13 different trusses. MI 4: SAE A/�ty: � ) Date: 04/ bE COM 21/18 �,/ J FOR ST. LUCIE T� 3/05/2020 Q WYNNE BUIEWS CORP. 75 G DESCRIPTION:_ GARAG E R I G T CARLTON PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE 13 TRLISS DRAWINGS ARE ATTACHED TO LAYOUT M 11323 -7(�8-w 513 Comrntt� I@ �� ® t P MiTek RE: M11323 MITek USA, Inc. M11323 6904 Parke East Blvd. Tampa, FL 33610-4115 Site Information: Customer: WYNNNE DEVELOPEMENT CORP Project Name: M11323 Lot/Block: Model: CARLTON Address: N/A Subdivision: City: PORT ST LUCIE State: FL General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 165 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 13 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date 1 T1988459A 7/7/2020 AOVW41 NM%Y 2 T19884597 A5 7/7/2020 3 T19884598 A6 7/7/2020 FI LE Cu 4 T19884599 A7 7/7/2020 5 T19884600 A8 7/7/2020 6 T19884601 A9 7/7/2020 7 T19884602 GRA 7/7/2020 8 T19884603 GRB 7/7/2020 9 T19884604 J2 7/7/2020 10 T19884605 J4 7/7/2020 11 T19884606 J6 7/7/2020 REVIEWED FOR 12 T19884607 J8 7/7/2020 13 T19884608 KJ8 7/7/2020 CODE COMPLIANCE ST. LUCIE COUNTY socc , This item has been electronically signed and sealed by Velez, Joaquin using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies The truss drawing(s) referenced above have been prepared by MiTek rect supervision based on � theparame parameters provided Inc under my by Chambers Truss. �%OP'O'U I N / VET Truss Design Engineer's Name: Velez, Joaquin � ••��c E N SF•.� ����� My license renewal date for the state of Florida is February 28, 2021. Florida COA: 6634 No 68182 IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. STATE OF ,O N A t�- %% 11111 Joaquin Velez PE No.68182 MITek USA, Inc. Fl. Cert 6634 6904 Parke East Blvd. Tampa FL 33610 July 07, 2020 1 of 1 Velez, Joaquin --] Job Truss Truss Type Qty PlyTJob r T79884596 M11323 A COMMON 9 rence o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:27 2020 Page 1 I D:a3B4PavKnnZweXyJckSFBgyuFUN-bAjL909k_l Hpv5SDpc_pEKrtnVLQuvtwTtLrJ WzUUjw 1-0-0 6-7-13 12-4-13 17-0-0 21-7' 274-3 340-0 5 0- -0.0 6-7-13 5.9-0 4-7-3 4-7-3 5-9-0 6-7-13 -0-0 �1 0 3x6 = 4.00 12 4x5 = 27 17 '" 15 -" -' 14 '" 12 2x3 II 4x6 = 3x8 = 3x8 = 4x6 = 2x3 II 6-7-13 12 4-13 21-7-3 27-4-3 34-0-0 6-7-13 5 9-0 9-2-7 5-9-0 6-7-13 Plate Offsets (X,Y)— [2:0-0-2,Edge), [10:0-0-2,Edge) LOADING (psf) SPACING- 2-M CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.39 TCDL 7.0 Lumber DOL 1.25 BC 0.58 BCLL 0.0 Rep Stress Incr YES WB 0.65 BCDL 10.0 Code FBC20171TP12014 Matrix -MS Scale = 1:57.8 3x6 = DEFL. in (loc) Well Ud PLATES GRIP Vert(LL) 0.3214-15 >999 360 MT20 244/190 Vert(CT) -0.61 14-15 >670 240 Horz(CT) 0.12 10 n/a rile Weight: 163 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD BOT CHORD 2x4 SP M 30 BOT CHORD WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-179(LC 8) Max Uplift 2=-832(LC 10), 10=-832(LC 10) Max Grav 2=1362(LC 1), 10=1362(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=3419/2395, 3-5=-2771/2031, 5-6=-2770/2152, 6-7=-2770/2152, 7-9=-2771/2031, 9-10=3419/2395 BOT CHORD 2-17=-2132/3213,15-17=-2132/3213,14-15=-126912000,12-14=-2132/3213, 10-12=-2132/3213 WEBS 6-14=635/983, 7-14=313/362, 9-14=-689/499, 6-15=-635/983, 5-15=-313/362, 3-15=-689/499 Structural wood sheathing directly applied or 3-7-12 oc purlins. Rigid ceiling directly applied or 4-11-7 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 13-7-3, Exterior(2) 13-7-3 to 20-4-13, Interior(1) 204-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. This item has been 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. electronically Signed and 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) sealed by Velez, Joaquin, PE 2=832, 10=832. using a Digital Signature. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 50 lb down and 47 lb up at Printed copies of this 15-0-0, and 50 lb down and 47 lb up at 19-0-0 on top chord. The design/selection of such connection device(s) is the responsibility of others. document are not considered 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). signed and Sealed and the signature must be verified LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 on any electronic copies. Uniform Loads (plf) Joaquin Velez PE No.68182 Vert: 1-6=-54, 6-11=-54, 18-21=-20 MiTek USA, Inc. FL Cert 6634 Concentrated Loads (lb) 6904 Parke East Blvd. Tampa FL 33610 Vert: 26=-50(F) 27=-50(F) Date: April 3,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 I Job ss Truss Type City Ply [A5 T19884597 M11323 SPECIAL 9 1 �M`11123 Job Reference (optional) c:nambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:28 2020 Page 1 ID:2GIScwwyY5hnGhXVARzUkuyuFUM-3MHjMkAMIKQgXE1 PNJV2mXOxRucedNo4iX5OryzUUjv 1-0-0 7-8-5 10-6.4 17-0-0 20-4-8 26-0-0 34-0-0 S-O- 0-0 7-8-5 2-9-15 6-5-12 3-4-8 5-11 8 7-8-0 -0-0 �1 0 5x8 MT18HS 11 4.00 12 Scale = 1:59.8 13 12 5x12 = 2x3 II 3x6 = 3x12 = 2.00 12 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC20171rP12014 CSI. TC 0.85 BC 0.90 WB 0.60 Matrix -MS LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* 6-14: 2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-179(LC 8) Max Uplift 2=-803(LC 10). 10=-803(LC 10) Max Grav 2=1312(LC 1), 10=1312(LC 1) I IA DEFL. in (loc) I/deft Lid PLATES GRIP Vert(LL) 0.76 14 >539 360 MT20 244/190 Vert(CT) -1.18 13-14 >344 240 MT18HS 2441190 Horz(CT) 0.36 10 n/a n/a Weight: 155 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 1-7-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 3-9-12 oc bracing. WEBS 1 Row at midpt 6-14 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5529/3776, 3-5=-5164/3538, 5-6=-5209/3667, 6-7=-2424/1902, 7-9=-2462/1813, 9-1 0=-3195/221 0 BOT CHORD 2-14=3466/5266, 13-14=-1305/2115, 12-13=-1948/2995, 10-12=-194812995 WEBS 3-14=355/314, 5-14=-293/354, 6-14=-2175/3326, 6-13=-279/534, 7-13=-237/277, 9-13= 786/560, 9-12=0/269 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Ex , C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 24-13 to 13-7-3, Exterior(2) 13-7-3 to 20-6-4, Interior(1) 20-6-4 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing atjoint(s) 2 considers parallel to grain value using ANSIfTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except (jt=lb) 2=803, 10=803. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 T19884598 M11323 A6 SPECIAL 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:29 2020 Page 1 I D:2GIScwwyY5hn GhXVARzUkuyuFU M-YYr6a4 B_WeYX90cbw00HJlx7ilyP Mm6DxBgy00zU Uju �1-0-0, 8-11-11 16-0-0 18-0.0 20�-8 25.11-15 34-0-0 g5-0-q 1-0-0' B-11-11 7-0-5 2-0-0 2-0-8 5-7-7 8-0-1 00 4.00 12 3x12 = 2.00 12 6x10 MT18HS = 5x6 = 10-6-4 11-0 16-0 q 204-8 25-11-15 34-0-0 10-6-4' 45-12 -0-0 4,-8 5.7-7 8-0-1 Plate Offsets (X,Y)— [2:0-1-15,Edge], [3:0-3-0,Edge], [5:0-5-0,0-1-13], [7:0-2-7,Edge], [9:0-0-6,Edge] LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.81 TCDL 7.0 Lumber DOL 1.25 BC 0.93 BCLL 0.0 Rep Stress Incr YES WB 0.86 BCDL 10.0 Code FBC2017/rP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP M 30 *Except* 3-5,6-7: 2x4 SP M 31 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* 5-14: 2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-169(LC 8) Max Uplift 2=-803(LC 10), 9=-803(LC 10) Max Grav 2=1312(LC 1),9=1312(LC 1) Scale=1:61.9 3x6 = DEFL. in (loc) I/deft Ud PLATES GRIP Vert(LL) 0.69 14 >590 360 MT20 244/190 Vert(CT) -0.92 14-17 >443 240 MT18HS 2441190 Horz(CT) 0.34 9 n/a n/a Weight: 157 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 24=5491/3336, 4-5=-5095/3071, 5-6=2314/1551, 6-8=2398/1533, 8-9=-3199/1981 BOT CHORD 2-14=3040/5224, 13-14=-1195/2361, 12-13=-1123/2199, 11-12=-1731/3001, 9-11=1731/3001 WEBS 4-14=-492/513, 5-14=1707/2959, 5-13=-405/196, 6-13=-179/522, 8-12=-893/660, 8-11=0/303 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=1b) 2=803, 9=803. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 511912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall Iva building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTPlf Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke Fast Blvd. Safety information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type __J Qty Ply M11323 ' T19884599 M11323 A7 SPECIAL 1 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:30 2020 Page 1 ID: WSJgpGwal Ppeur6h k9 UjG5yuFU L-OIPUnQCcHygOmYBnUkXW ryTl F1145C1N9gaVwrzU Ujt 1-0-0 8-10-10 14-01 20-0-0 25-11-15 34-0-0 5-0 0-0 8-10-10 5 1 6 6 0-0 5-11-15 8-0-1 -0-0 aI1 Ann 3x12 =:: 2.00 12 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017frP12014 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* 4-11: 2x4 SP M 30 REACTIONS. (size) 2=0-8-0, 7=0-8-0 Max Horz 2=-149(LC 8) Max Uplift 2=-803(LC 10), 7=-803(LC 10) Max Grav 2=1312(LC 1), 7=1312(LC 1) 5x8 = 5x6 = 2x3 11 3x6 = Scale=1:60.8 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TC 0.83 Vert(LL) 0.66 11 >616 360 MT20 244/190 BC 0.90 Vert(CT)-1.1010-11 >369 240 MT18HS 2441190 WB 0.95 Horz(CT) 0.34 7 n/a n/a Matrix -MS Weight: 147 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 cc purlins. BOT CHORD Rigid ceiling directly applied or 4-0-2 cc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5484/3370, 3.4=-5116/3126, 4-5=2229/1544, 5-6=2448/1599, 6-7=-3169/1993 BOT CHORD 2-11=-3071/5219,10-11=-1590/2874,9-10=-1738/2968,7-9=-1738/2968 WEBS 3-11=-419/443, 4-11 =-1 466/2647, 4-10=812/448, 5-10=-205/487, 6-10=-785/575, 6-9=0/272 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent waterponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing atjoint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ito uplift atjoint(s) except Gt=lb) 2=803, 7=803. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not my a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPH Quality Cdfeda, DSO.89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply M11323 d T19884600 M11323 AB SPECIAL 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 M7ek Industries, Inc. Fri Apr 3 07:54:31 2020 Page 1 ID: W SJq pGwa IPpeur6hk9Uj G5yu FUL-Uxzs_mCE2FoFOiI_2 R210AOTj6eKgj EW OUJ2S HzUUjs 1-0-0 8-8-0 12-0-0 15.8.4 208 22-0 0 24-8-12 34-0-0 5-0 -0-0 8-8-4 3 3-12 3-8-4 4284 1-7 8 2-8-12 9-3 4 0-0 Scale = 1:60.6 4.00 12 5x6 = 3x4 = 4 21 5 2x3 11 5x8 = 6 22 7 9r1 / 12 11 5x12 = 3x4 = 4x5 = 3x12 _ 2.00 12 10-6-4 20-4-8 22-01 34-" 10-6-4 9-10-4 1-7-8 12-0-0 Plate Offsets (X,Y)— [2:0-1-15,Edge], [7:0-5-8,0-2-8] LOADING (psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/deb Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.78 Vert(LL) 0.65 12-13 >624 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.90 Vert(CT) -1.08 12-13 >379 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.69 Horz(CT) 0.33 9 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 154 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 3-11-11 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-129(LC 8) Max Uplift 2=-803(LC 10), 9=-803(LC 10) Max Grav 2=1312(LC 1), 9=1312(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=5488/3444, 34=5117/3183, 4-5=-3911/2497, 5-6=-2576/1770, 6-7=-2586/1779, 7-8=2663/1762, 8-9=3021/1971 BOT CHORD 2-13=3143/5224, 12-13=-1956/3292, 11-12=-1369/2481, 9-11 =-1 705/2827 WEBS 3-13=396/420, 4-13=1028/1721, 5-13=300/797, 5-12=-894/601, 6-12=-265/263, 7-12=294/391, 7-11=374/691, 8-11=-535/502 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2.4-13, Interior(1) 24-13 to 31-7-3, Extedor(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ' This item has been 6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. electronically Signed and 7) Bearing atjoint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify sealed by Velez, Joaquin, PE capacity of bearing surface. using a Digital Signature. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ito uplift at joint(s) except ([t=1b) Printed copies of this p 2=803, 9=803. document are not considered signed and sealed and the signature must be Verified on any electronic copies. Joaquin Velez PE No.68182 Miiek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Ouallty, Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Ply • �Qty �M11323 T19884601 M11323 A9 HIP 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:32 2020 Page 1 ID:_etcl cxC3ixVV?huts?ypJyuFUK-y7XEC6DspZw6OsKAc9Z_xNZIBW4CZ7Mfd83c?jzUUjr 1-0-0 6-7-15 10-0-0 15-2-14 20-4-0 24-0-0 27-t 34-0-0 5-0- -0-0 6-7-15 3-4-1 5 2-14 5-1-2 3.8-0 3 4-1 6-7-15 -0-0 4.00 12 3x5 = 4x4 = 3x4 = 2x3 II 48 = 4 24 525 26 6 27 7 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017/TPI2014 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2k4 SP M 30 WEBS 2x4 SP No.3 3x8 = 3x6 = 6x8 = 3x6 = 3x4 = Scale = 1:58.6 3x5 11 CSI. DEFL. in (loc) I/defi L/d PLATES GRIP TC 0.35 Vert(LL) -0.18 11-21 >917 360 MT20 244/190 BC 0.54 Vert(CT) -0.3811-21 >432 240 WB 0.89 Horz(CT) 0.02 13 n/a n/a Matrix -MS Weight: 156 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 5-11-9 oc puffins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size) 2=0-8-0, 9=0-8-0, 13=0-8-0 Max Horz 2=109(LC 9) Max Uplift 2=-430(LC 10), 9=-249(LC 10), 13=928(LC 10) Max Grav 2=685(LC 19), 9=386(LC 20), 13=1616(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=1275/1025, 3-4=913/708, 4-5=-829r705, 5-6=-565/807, 6-7=-565/807, 7-8=-104/278, 8-9=-341/235 BOT CHORD 2-15=836/1187, 13-15=-34/309, 11-13=-256/348, 9-11 =-1 24/304 WEBS 3-15=425/501, 5-15=-444/665, 5-13=-1215/1079, 6-13=-264/300, 7-11=-255/396, 8-11=-461/521, 7-13=8371703 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 24-13, Interior(1) 24-13 to 5-2-5, Exterior(2) 5-2-5 to 14-9-11, Interior(1) 14-9-11 to 19-2-5, Exterior(2) 19-2-5 to 28-9-11, Interior(1) 28-9-11 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=1b) 2=430, 9=249, 13=928. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 A WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 511912020 BEFORE USE. Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall MiTek* design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing 1 VliTe k• Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTPII Qualify Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 T19884602 M11323 GRA HIP 1 1 Job Reference o tional unamoers I russ, Inc., con coerce, t-L 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:33 2020 Page 1 I D:_etC1 cxC3ixVV?huls?ypJyuFUK-QK4cPSEUat2zdOvM9s4DTb5n5vPvlY6proo9XAzUUjq 1-0-0 8-0-0 11-1-1 17-" 18.6.0 22-2-2 26A0 34-0-0 5-0 0-0 8-0-0 3 1-1 5-10-15 1-6-0 3 8-2 3-9-14 8-0-0 -0-0 �1 6 THIS TRUSS IS NOT SYMMETRIC. PROPER ORIENTATION IS ESSENTIAL. 4x4 = Scale=1:60.6 3x5 —_ 3x6 II 3x6 = 6x8 = 3x6 = 6x8 = 4x4 = 6x8 = TRUSS DESIGNED FOR WIND LOADS IN THE PLANE OF THE TRUSS ONLY. FOR STUDS EXPOSED TO WIND (NORMAL TO THE FACE), SEE STANDARD INDUSTRY GABLE END DETAILS AS APPLICABLE, OR CONSULT QUALIFIED BUILDING DESIGNER AS PER ANSI/TPI 1. 18-6-0 26-M LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Code FBC20171rP12014 CSI. TC 0.91 BC 0.57 WB 0.98 Matrix -MS DEFL. in (loc) I/defl Ltd Vert(LL) 0.20 24-35 >914 360 Vert(CT) -0.24 29-32 >552 240 Horz(CT) 0.02 22 n/a n/a PLATES GRIP MT20 244/190 Weight: 194 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 4-2-5 oc puriins. BOT CHORD 2x4 SP M 30 Except: WEBS 2x4 SP No.3 1 Row at midpt 8-21 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 7, 8, 19, 17, 14 REACTIONS. All bearings 0-8-0. (lb) - Max Horz 2=-179(LC 6) Max Uplift All uplift 100 lb or less at joint(s) except 2=-351(LC 8), 27=-1168(LC 8), 26=-1495(LC 8). 22=-625(LC 8) Max Grav All reactions 250 lb or less at joints) except 2=487(LC 17). 27=2232(LC 13), 26=2929(LC 14), 22=984(LC 14) FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-621/387, 3-5=-304/838, 5-7=-588/1209, 7-8=-588/1209, 8-12=-588/1209, 12-13=-588/1209,13-15=-588/1209,15-16=-588/1209,16-18=-588/1209, 18-20=-2230/1280, 20-21=-2230/1280, 21-22=-2271/1263, 6-9=-126/305, 9-11=-106/363, 11-14=-193/412, 14-17=-94/271, 19-21 =1 43/272 BOT CHORD 2-29=247/677, 27-29=-189/540, 26-27=779/446, 24-26=-411/653, 22-24=-1083/2108 WEBS 3-29=-500/1176, 3-27=-1766/911, 5-27=748/622, 5-26=-546/351, 13-26=-946/617, 18-26=-2412/1474,18-24=-846/1780, 21-24=-35/351,4-5=-608/514,19-20=335/305, 14-15=-556/407, 11-12=-254/54 NOTES- 1) Unbalanced roof live loads have been considered for this design. This item has been 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 electronically signed and 3) Provide adequate drainage to prevent water ponding. Sealed by Velez, Joaquin, PE 4) All plates are 2x3 MT20 unless otherwise indicated. using a Digital Signature. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. • Printed copies of this 6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. document are not considered 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 351 lb uplift at joint 2, 116B lb uplift at signed and sealed and the joint 27, 1495 lb uplift at joint 26 and 625 lb uplift at joint 22. Signature must be Verified 8) Girder carries hip end with 8-0-0 end setback. On any electronic Copies. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Joaquin Velez PE No.66182 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at MiTek USA, Inc. FL Cent 6634 26-0-0, and 967 lb down and 461 lb up at 8-0-0 on bottom chord. The design/selection of such connection device(s) is the 6904 Parke East Blvd. Tampa FL 33610 responsibility of others. Date: 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). April 3,2020 andard ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/192020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DS11-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Type City Ply ]Truss T19884602 M11323 GRA HIP 1 1 �]V!11323 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MTek Industries, Inc. Fri Apr 3 07:54:33 2020 Page 2 I D:_etC1 cxC3ixW?huls?ypJyuFUK-QK4cPSEUat2zdOvM9s4DTb5n5vPvlY6proo9XAzUUjq LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 21-23=54, 29-30=-20, 24-29=-47(F=-27),24-33=-20, 3-11=-126(F=-72), 11-21=-126(F=-72) Concentrated Loads (lb) Vert: 29=-641 (F) 24=-641(F) ®WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not bat a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M(Te k• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS17TP11 Quality Criteria, DSLI-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type oty PiyTJob • T19884603 M11323 GRB HIP 1 rence o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:34 2020 Page 1 ---0 -ID2:SrRaEyyrgO4M78G4raWBLWyuFUJ-uWe7doF7LAApF9UZjacSOo e_iJjP10by4SYi3czUUjp 8-0-0 380 17-0-0 0' 26-0-0 34-0-0 58 34 0 5-8-0 8-M 5:090- -0-0 8-0-0 3 4- 46 = 5x12 MT18HS = 4x10 = 4.00 12 2x3 II 4x6 = I, 2x3 II 3 23 4 5 6 7 24 3x6 11 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr NO BCDL 10.0 Code FBC2017/rPI2014 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3'ExcepV 4-14,7-13: 2x6 SP No.2 5x6 = 6x12 = 6x12 = 5x6 = 5x12 MT18HS = 3x6 11 Scale=1:58.6 4x6 = 6-8-0 5-8-0 8-0-0 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TC 0.80 Vert(LL) 0.2216-19 >999 360 MT20 244/190 BC 0.68 Vert(CT) -0.30 16-19 >820 240 MT18HS 244/190 WB 0.90 Horz(CT) 0.06 9 n/a n/a Matrix -MS Weight: 153 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-1-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 5-3-14 oc bracing. WEBS 1 Row at midpt 3-14, 8-13, 6-13 REACTIONS. (size) 2=0-8-0, 13=0-8-0, 9=0-8-0 Max Harz 2=90(LC 7) Max Uplift 2=-853(LC 8), 13=-2590(LC 8), 9=-345(LC 8) Max Grav 2=1451(LC 13), 13=4743(LC 15), 9=528(LC 14) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3625/1950, 34=2080/1236, 4-6=-2080/1236, 6-7=-1296/2589, 7-8=-1296/2589, 8-9=-751/370 BOT CHORD 2-16=-1729/3460, 14-16=-1753/3525, 11-13=-262/733, 9-11=-241/668 WEBS 3-16=-435/1209,3-14=-15521774,4-14=-837/691, 7-13=-8781713,8-13=-3635/1919, 8-11=-432/1204,6-14=-1453/2814,6-13=-3198/1807 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10: Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise Indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 853 lb uplift at joint 2, 2590 lb uplift at joint 13 and 345 lb uplift at joint 9. 8) Girder carries hip end with 8-0-0 end setback. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at 26-0-0, and 967 lb down and 461 lb up at 8-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-8=-131(F=-77), 8-10=-54, 16-17=-20, 11-16=-49(F=-29), 11-20=-20 This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA,.Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 tin Ann 2 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overalls building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safelylnformatlon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply M11323 • T19884603 M11323 GRB HIP 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 5.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:35 2U2U Page 2 ID:SrRaEyyrg04M78G4raW BLWyuFUJ-MiCNg7G16UIgtJ31HH7hYOB9Sj3emSr6J6HGb2zUUjo LOAD CASE(S) Standard Concentrated Loads (Ib) Vert: 16=-641(F) 11=-641(F) ®WARNING • Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Ply M11323 �Qty T19884604 M11323 J2 MONO TRUSS 8 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:35 2020 Page 1 ID:x17zSIzTbJCDIIrGPH1 QukyuFUI-MiCNg7G16UlgtJ3IHH7hYOBJ7jCDmgz6J6HGb2zUUjo 1-0-0 2-M 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 TCDL 7.0 Lumber DOL 1.25 BC 0.07 BCLL 0.0 Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC2017rrP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=67(LC 10) Max Uplift 3=-28(LC 10). 2=136(LC 10), 4=-3(LC 7) Max Grav 3=39(LC 15), 2=141(LC 1), 4=31(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale = 1:7.8 2-0-0 DEFL. in (loc) I/deft L/d PLATES GRIP Vert(LL) -0.00 7 >999 360 MT20 244/190 Vert(CT) -0.00 7 >999 240 Horz(CT) -0.00 3 n/a n/a Weight: 8 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 28lb uplift at joint 3, 136lb uplift at joint 2 and 3 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL $3610 Date: April 3,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not m� a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type city Ply M11323 T19884605 M11323 J4 MONO TRUSS 8 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:36 2020 Page 1 ID:PDYLfd_5MdK4MSQTz?ZfRxyuFUH-gvml2TGNtoQXUTexr?ew5DjOW7UmV7DFYm 1 pBUzUUjn -1-0-0 4-0-0 1-0-0 4-0-0 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.39 Vert(LL) 0.02 4-7 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.37 Vert(CT) -0.02 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017rrP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=104(LC 10) Max Uplift 3=-80(LC 10), 2= 16'1(LC 10), 4=-7(LC 10) Max Grav 3=90(LC 1), 2=207(LC 1), 4=69(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale=1:11.1 PLATES GRIP MT20 244/190 Weight: 14 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 80 lb uplift at joint 3, 161 lb uplift at joint 2 and 7 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing 1 V q IiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPlf quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Type Qty Ply M11323T19884606 Putss M11323 MONO TRUSS 8 1 Job Reference (optional) fuss, Inc., Fort Pierce, FL 3x4 = 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:36 2020 Page 1 ID:tP6jtz_j7xSx_c fXi4uz9yuFUG-gvml2TGNtoQXUTexRewSDjR?7MUV7DFYmlp8UzUUjn 6-0-0 Scale = 1:14.6 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.36 Vert(LL) 0.11 4-7 >629 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.83 Vert(CT) -0.12 4-7 >617 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017rrPI2014 Matrix -MP Weight: 20 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=142(LC 10) Max Uplift 3=-131(LC 10), 2=-194(LC 10), 4=-8(LC 10) Max Grav 3=145(LC 1), 2=279(LC 1). 4=102(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131 lb uplift at joint 3, 194 lb uplift at joint 2 and 8 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall Not building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek` Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 • T19884607 M11323 J8 MONO TRUSS 20 1 Job Reference (optional) Chambers Truss, Inc., , Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:37 2020 Page 1 ID:tP6jtzJ7xSx_c fXi4uz9yuFUG-J5K7FpH7d5YO6dD80199eRGYgXquEaTPmOmNgxzUUjm 1-0-0 8-0-0 1-0-0 8-0.0 3x5 = 8-0-0 LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.62 Vert(LL) 0.26 4-7 >367 360 TCDL 7.0 Lumber DOL 1.25 BC 0.38 Vert(CT) -0.30 4-7 >319 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SIP M 30 BOT CHORD 2x4 SP M 31 REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=180(LC 10) Max Uplift 3=-175(LC 10), 2=-228(LC 10), 4=15(LC 10) Max Grav 3=188(LC 1), 2=352(LC 1), 4=145(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale=1:17.4 PLATES GRIP MT20 244/190 Weight: 26 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 3-1-13, Extedor(2) 3-1-13 to 7-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 175 lb uplift at joint 3, 228 lb uplift at joint 2 and 15 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using, a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING -verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5f1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and propedy Incorporate this design into the overall r building design. Bracing Indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safelylnformatfon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type city Ply M11323 • T19884608 M11323 KJ8 MONO TRUSS 4 1 Job Reference (optional) t:namoers I russ, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:38 2020 Page 1 I D: Lcg54J7Lu EancmZr4Qb7 W MyuFUF-n HuVT9ldOPg FknoKyPg OAeooawBGzwZY74WwCNzUUjI 1-5-0 7-3.4 11-3-0 1-5-0 7-3-4 3-11-12 Scale = 1:20.3 3x4 = ono 5 3x4 = 7-34 11-3-0 7-3-4 3-11-12 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.29 Vert(LL) 0.07 7-10 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.30 Vert(CT) -0.12 7-10 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.46 Horz(CT) 0.02 6 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 44 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 8-9-6 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 4=Mechanical, 2=0-11-5, 6=Mechanical Max Horz 2=244(LC 8) Max Uplift 4=-205(LC 8), 2=-305(LC 8), 6=-286(LC 8) Max Grav 4=245(LC 13), 2=466(LC 1), 6=590(LC 13) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-1151/523 BOT CHORD 2-7=-687/1126, 6-7=-687/1126 WEBS 3-7=0/330, 3-6=-1236f755 NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 205 lb uplift at joint 4, 305 lb uplift at joint 2 and 286 lb uplift at joint 6. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard This item has been 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 electronically signed and Uniform Loads (plf) sealed by Velez, Joaquin, PE 54 Vert: 1 s (pl Trapezoidal Loads (plf) using a Digital Signature. Vert: 2=0(F=27, 8=27)-to-4=-152(F=-49, 6=-49), 8=0(F=10, B=10)-to-5=-56(F=-18, 8=-18) Prp copies of this tc0 ine document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ® WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not H a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall r building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information avallable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Symbols Numbering System ® General Safety (Votes PLATE LOCATION AND ORIENTATION Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss �rr.. and fully embed teeth. 016 r For 4 x 2 orientation, locate plates 0- yid' from outside edge of truss. This symbol indicates the required direction of slots in connector plates. ' Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the �r output. Use T or I bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TP11: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) 1 2 3 TOP CHORDS Ct-2 C2.3 WEBS cza 4 O U d c7.8 csa c5-6 BOTTOM CHORDS JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. © 2012 MiTek@ All Rights Reserved Nil MiTek° MiTek Engineering Reference Sheet: Mll-7473 rev. 5/19/2020 Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, Individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/rPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and In all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, If no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria. 21.The design does not take into account any dynamic or other loads other than those expressly stated.