A -LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that should be read
given special attention by all persons installing trusses.
5PAGING NOTE
ALL TRUSSES ARE TO BE 5ET
AT 2.-Oz ON CENTER'
EXGEPT A5 NOTED
l�
MULTIPLE PLY TRUSSES MUST BE
ASTENED TOGETHER PER ENGINEERIN
BEFORE SETTING. REFER TO
ENGINEERING DRAWING TO DETERMINE
A IF MULTIPLE PLY.
i
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
30' Span or less ® 30' to 60' Span
60 degrees Spree er Bar
or less
1 2 09 F—APProz 2/3 to
/ Line 1/2-of Span
Tog Line span approx.
BCSI REFER TO BCSI
REFER TO
TTruss must be set this way if crane used.
Truss must be set this way if crane used.
This is an example, truss may not match.
Trussis on example, your truss may not match.
Insist crane operator sets truss this way.
Insist crane operator sets truss this way.
j
i
a
lit
s
AIR HANC7LIE=F? NOT Ill
UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES
ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR
ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT
WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS.
CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR.
f
U REPRESENTS A HANGER
Carrying Girder
For Truss to Truss
Connections see
hanger/connector Nails must be as
shown. Guide tabs o
schedule In engineering Dome angle fills.
package.
Carried Truss
SEAT
PLATES BY CHAMBERS
INDICATES LOAD BEARING WALL
REQUIRED BY TRUSSES
SUPPLIED BY BUILDER
AT A HEIGHT OF 8'-1"
ABOVE FINISHED FLOOR
12
4.00
08-1
upset=1J4'• heel=315/16"
PLUMB CUT END
1,
2 x 4 Top Chord
WALL HEIGHT ll
TYPICAL END DETAIL
12
4.00 I
.00000
12 2.00 8-1
upset=l/4" heel=315/16"
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT III
END DETAIL: A
® ARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF 171- 231 IN Lwess
.NGTH - -
® Do not stand on trusses until they are braced per BCSI & properly nailed to straps & hangers
Ea aBR��aT,oNgGREEMENT
sw
20,
14'
6-4- TI 9'-6-
— - — — — 34
GARAGE, LEFT
NOT ft STARTED UNTIL a tr AGREEMENT IS SIGNED & RETURNED
r The, lapel description Of the property where the trusses will be Installed is:
The underalgned ecknowletlgea end agrees:
1: Trusses will be made In smct accordance w —`—
whlch b fh0 sole atrlh10ry for detarmininpsucceasrul ab canon of a trmussne �aprem layout,
2. All dimensions h this layout have bean venfied by the undersigned.
34' 3. Unless written hall Is provided by csHfied mall to Chambe a 7 ties Within ten (10)
days of delivery the undersigned agrees that no backchargas will be ellowe Wih the event
such wnuen not la furnished Cha mere Trues shall have three 3 busJnass day$ In which
20' 14' to beglo repairs rgequlred, or to subsu a other Wssea, aChamben)opu$n.'
4. The e I sl ned acknowledpas receipt of "BCSI 1-03"summary sheet by'rPl & yv7gq,
'S, Delivery la to Job site. It la the buyars'reaponalbiury to make the Job slle suitable for
delivery,of Chambers Thum has the sots authority to determine the suitability or th Job site o} a
Portion buyer
Is Job site for delivery, Chambers Truss will be responsible /or dump delivery only.
The buyer la responsible for additional delivery expenses If Chambers Truss has to redeliver
because Job site is dot prepared for delivery or buyer Ia not prepared for delivery of trusses,
Buyer Is responsible to Chambers Trues for towing wale duo to sue conditions.
S. Price as shown Iq paregraph 7 below Is subJeclto change If any ehangea are. made In
this. leyOUL A $50 per hour fee for revisions may be change
e If an T
7; Thin Is a PURC
��Will
l®'®Ir
I®I®I®
Lq
ro
Is
VA
1
100
II
001101
�J
11010
IPA
110
�11010_
NilElEpp
.100
011
11011
1110m
lop,
CIA
PO
PFO
r
0
_114
• %
rr
i%////fit//%r
/
fr
�/�
�/////I//ii�/�riZZA01
''
��
//.li//
i�,/,li////li///�i�//!✓
• . RASE ORDER to Chambers, Truss of the sum agreed to, or If nq
agreement a reasonable price. Invoice will be made on delivery and paid within terms of net
on delivery. Invoice may be made at scheduled date of delivery If buyer cannot accept
delivery of fabricated bu$sea, Tha undersigned agrees to pay unambers,7ryss reasonable
charge
fee for wlleClbns In evert of payment not timely made. 1.12 %per month servJce
charge will be added for all sums not pal, within terms.
S. Signature or Initials anywhere on this sheet wnslltutas agreement to all terms herein,
9, In consideration of Chambers Truss eMending credit for this material the undersigned
' unwndl0onally guarantees payment when due of any and all Indebtedness owed to
Chembere Truss by any entity receiving material and the undersigned agrees to pay such
Indebtedness Including adomeye fees, If default in payment for material be made by tire
recipient.-
. 10. In the event of any litigation concerning this agreement, the Items fumished hereunder
be payments referred to herein, the, parlorida t agree that the sole venue for any such action will
be Saint Payments
r County, herein
11. Design responsibllitles are per "National Standard And Recommended Guidelines On
Responsibilities For Construction Using Metal Plate Connected Wood Trusses
ANSI/rIal/WTCA 4.2002
DATED .
SIGNED -
FOR TITLE
-- --- —�-
Aspreaderbarmay be re9tLued POr "BCSI 1-03" 4� pmygnt Ir#ury& darnMge
= Multiple ply trusses must be fastened together per engineering
before they are set, failure to do so can resulit in roof collapgo,
Temporary and permanent bracing are required and can save life
and property and is the resPonslblllty of the truss erector.
Study the contents of the information packet Included on delivery
before setting trusses.
Thames must be astaW braced Perdssign 6 Pint �w Y& damage,
Trusses must be set plumb and square
Do not sat bunks or stack of plywood, roofing material or any
other concentrated loads on trusses, this Can cause collapse.
D0 NOT SE'T TRUSSES USING TMIS LA p(7
USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES
CF1�MBERS TRUSS INC
I_.
3105 Oleander Avenue
Fort Pierce; Flollda 34982-6423
800-551.5932
Fort Pierce 772-465.2012 Fax 772-465-8711
Vero Beach 772-569-2012 Stuart 772-2863302 '
The Architect's or Architect's representative's shop drawing approval is NOT a
"double check" of the. Contractor.
The contractor shall remaro responsible
for checking field measurements and
other construction criteria. Architect's
approval covers genera! roof shape,:,
review of truss strapping, and loading on
structure ifram gravity a`ntl Uplift Ida and
their resp !ye lacdtio s.
Approved Ely:
Date __
92.0/93.2 MITEK 4.2 Braden den A,1.A P.A.
DESIGN CRITERIA
County SAINT LUCIE
Building Department SAINT LUCIE COUNTY
Wind Design Criteria ASCE 7-2010
3 0 (k) Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-10
b (Roofing Material Shingle or Shake
e�IN Loading in PSF Roof R.D.L.
H o Top Chord Live 20
w,I Top Chord Dead 7 4.2
/l Bottom Chord Live 10 Non -Concurrent
° Bottom Chord Dead 10 3
m c� � I TOTAL Load 37 7.2
R o M Duration Factor 1.25
R Wind Speed 165mph
y w Top Chord C.B. Sheeting by builder.
Bottom Chord C.B. Sheeting by builder.
Highest Mean Height 14'-0"
Building Type ENCLOSED
Building Category II:Non Restrictive
Exposure Category C
Barrier Island No
Conforms to FBC 2017
R.D.L =Restrainin Dead Load C.B.=Continuous Bracing
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
Buildin Desi ner and/or Engineer of Record.
Chambers Truss Inc. Drawing Name. M11 3
land Scale: 1 /4 = 1'
F11 72 total trusses, 13 different trusses.
alls MI 4: SAE ACAD: SAE Reviewed By:
if / Date: 04/24/12 Revised: 02/21/18
FOR Revised: 3/05/?0
OR
Q NE BUILDII i3 PLIANCE
_ ` DESCRIPTION:---ST. LUCIE COUNTY
GARAGE RIGHT CARLTON BOCC
PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE
13 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT M11323
1'W7
MiTek
RE: M11323
MiTek USA, Inc.
M11323
6904 Parke East Blvd.
Tampa, FL 33610-4115
Site Information:
Customer: WYNNNE DEVELOPEMENT CORP Project Name: M11323
Lot/Block:
Model: CARLTON
Address: N/A
Subdivision:
City: PORT ST LUCIE
State: FL
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017/TP12014
Design Program: MiTek 20/20 8.1
Wind Code: ASCE 7-10
Wind Speed: 165 mph
Roof Load: 37.0 psf
Floor Load: N/A psf
This package includes 13 individual, dated Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No.
Seal#
Truss Name
Date
1
T1988459
A
6/25/2020
2
T19884597
A5
6/25/2020
FILE
3
T19884598
A6
6/25/2020
4
T19884599
A7
6/25/2020
5
T19884600
A8
6/25/2020
6
T19884601
A9
6/25/2020
REVIEWED FAIR
8
9
T19884603
T19884604
GRB
J2
6/25/2020
6/25/2020
����®IlIIPLIAtfVCE
10
11
T19884605
T19884606
J4
J6
6/25/2020
6/25/2020
w� 7T Y
�. UCIE COUNT
ST.
12
T19884607
J8
6/25/2020
p�
13
T19884608
KJ8
6/25/2020
ROM
This item has been electronically signed and sealed by Velez, Joaquin using a Digital Signature.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies
The truss drawing(s) referenced above have been prepared by
MiTek USA, Inc under my direct supervision ,`,t,ttt1111rrI,�,,
based on the parameters provided by Chambers Truss. `,��OPQU1 N
Truss Design Engineer's Name: Velez, Joaquin � �.,��G�E NS�,.�
My license renewal date for the state of Florida is February 28, 2021.
Florida COA: 6634 No 68182
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the engineer named is licensed in the jurisdictions) identified and that the
designs comply with ANSI/TPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to MiTek. Any project specific information included is for MiTek
customers file reference purpose only, and was not taken into account in the preparation of
these designs. MiTek has not independently verified the applicability of the design
parameters or the designs for any particular building. Before use, the building designer
should verify applicability of design parameters and properly incorporate these designs
into the overall building design per ANSI/TPI 1, Chapter 2.
-33: STATE OF
4 O R 10 P `_`��
���s`S�O N AL E����•
,���11111111tt��
Joaquin Velez PE No.68182
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610 June 25, 2020
1 of 1 Velez, Joaquin
Job
Truss
Truss Type
Ply
M11323
r
�Qty
T19884596
M11323
A
COMMON
9
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:64:27 2020
ID:a3B4PavKnnZweXyJckSFBgyuFUN-bAjL909k 1Hpv5SDpc_pEKrtnVLQuvtwTlLrJN
11-0-0. 6-7-13 12-4-13 17-0-0 21-7-3 27.4-3 34-0-0
�1
6
3x6 =
4.00 12 4x5 =
27
17 15 14 "' 12
2x3 II 4x6 = 3x8 = 3x8 = 4x6 2x3 II
Scale = 1:57.8
3x6 =
6-7-13 12.4-13 21-7-3 271-3 34-0-0
6-7-13 5-9-0 9-2-7 5-9-0 6-7-13
Plate Offsets (X,Y)—
[2:0-0-2,Edge), [10:0-0-2,Edge)
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.39
Vert(LL) 0.32 14-15 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.58
Verl(CT) -0.61 14-15 >670 240
BCLL 0.0
Rep Stress Incr YES
WB 0.65
Horz(CT) 0.12 10 n/a n/a
BCDL 10.0
Code FBC2017frP12014
Matrix -MS
Weight: 163 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x4 SP M 30 BOT CHORD
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 10=0-8-0
Max Horz 2=-179(LC 8)
Max Uplift 2=-832(LC 10). 10=-832(LC 10)
Max Grav 2=1362(LC 1), 10=1362(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=3419/2395, 3-5=-2771/2031, 5.6=-2770/2152, 6-7=-2770/2152, 7-9=2771/2031,
9-10=3419/2395
BOT CHORD 2-17=-2132/3213,15-17=-2132/3213,14-15=-1269/2000,12-14=-2132/3213,
10-12=-2132/3213
WEBS 6-14=635/983, 7-14=-313/362, 9-14=-689/499, 6-15=-635/983, 5-15=-313/362,
3-15=-689/499
Structural wood sheathing directly applied or 3-7-12 oc purlins.
Rigid ceiling directly applied or 4-11-7 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 13-7-3, Extedor(2) 13-7-3
to 20-1-13, Intenor(1) 20-4-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
This item has been
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL=10.Opsf.
electronically signed and
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except (jt=1b)
sealed by Velez, Joaquin, PE
2=832, 10=832.
using a Digital Signature.
6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 50 lb down and 47 lb up at
Printed copies of this
15-0-0, and 50 lb down and 47 lb up at 19-0-0 on top chord. The design/selection of such connection device(s) is the responsibility
of others.
document are not considered
7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
Signed and Sealed and the
signature must be verified
LOAD CASE(S) Standard
on any electronic copies.
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Joaquin Velez PE No.68182
Uniform Loads (pif)
Vert: 6-11=-54, 18-21=-20
MiTek USA, Inc. FL Cart 6634
Loads (l
Concentrated Loads (Ib)
6904 Parke East Blvd. Tampa FL 33610
Vert: 26=-50(F) 27=-50(F)
Date:
April 3,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,111-7473 rev. f0/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall
building design. Bracing indicatedis to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. Forgenerai guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job Truss
Truss Type
Ply
T19884597
M11323 A5
SPECIAL
�Qty
9
1
�M11323
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:28 2020 Page 1
ID:2GIScwwyY5hnGhXVARzUkuyuFUM-3MHjMkAMIKQgXE1 PNJV2mXOxRucedNo4iX50ryzUUjv
1-0-0 7-8-5 1% 4 17-0-0 20-4-8 264-0 34-0-0 5-0-
0-0 7-8-5 2-9-15 6-5-12 34 8 5 11 8 7-8-0 -0-0
5x8 MT18HS 11
4.00 12
Scale = 1:59.8
13 12
5x12 = 2x3 II 3x6 =
3x12 = 2.00 12
10.6.4 204-8
i264-0
34-0-0
' 10-6-4 9-10-4
5-11-a
7-8-0
Plate Offsets_(X,Y)—
[2:0-1 -15, Edge], [4:0-3-0,Edge], [10:0-0-6,Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/deft Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.85
Vert(LL)
0.76 14 >539 360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.90
Vert(CT) -1.18 13-14 >344 240
MT18HS
244/190
BCLL 0.0
Rep Stress Incr YES
WB 0.60
Horz(CT)
0.38 10 n/a n/a
BCDL 10.0
Code FBC2017/rP12014
Matrix -MS
Weight: 155 lb
FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 1-7-8 cc puriins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 3-9-12 cc bracing.
WEBS 2x4 SP No.3 *Except*
WEBS
1 Row at midpt 6-14
6-14: 2x4 SP M 30
OTHERS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 10=0-8-0
Max Horz 2=-179(LC 8)
Max Uplift 2=-803(LC 10), 10=-803(LC 10)
Max Grav 2=1312(LC 1), 10=1312(LC 1)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=5529/3776, 3-5=-5164/3538, 5-6=-5209/3667, 6-7=-2424/1902, 7-9=-2462/1813,
9-10=-3195/2210
BOT CHORD 2-14=-3466/5266, 13-14=-1305/2115, 12-13=-1948/2995, 10-12=-1948/2995
WEBS 3-14=-355/314, 5-14=-293/354, 6-14=-2175/3326, 6-13=-279/534, 7-13=-237/277,
9-13=786/560, 9-12=0/269
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; save=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 24-13, Interior(1) 24-13 to 13-7-3, Exterior(2) 13-7-3
to 20-64, Interior(1) 20-6-4 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise indicated.
This Item has been
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
electronically signed and
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
sealed by Velez, Joaquin, PE
will fit between the bottom chord and any other members.
using a Digital Signature.
6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
Printed Copies of this
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
document are not considered
2=803,10=803.
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
April 3,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. f010312015 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIyTPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Ply
M11323
T19884598
M11323
A6
SPECIAL
�Qty
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:29 2020 Page 1
ID:2GIScwwyY5hnGhXVARzU kuyu FUM-YYr6a4B_WeYX90cbw00HJlx7ilyP Mm6 DxB gy00zU Uju
�1-0-0 8-11-11 16-0-0 18-0-0 20-4 8 25-11-15 , 34-0-0 35-0-q
-0-0 8-11-11 7-0-5 2-0-0 2-4-8 5 7-7 8-0-1 0-0
4.00 12
3x12 = 2.00 12
LOADING (psf)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
7.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
YES
BCDL
10.0
Code FBC2017/TPI2014
LUMBER -
TOP CHORD
2x4 SP M 30'ExcepV
3-5,6-7: 2x4 SP M 31
BOT CHORD
2x4 SP M 30
WEBS
2x4 SP No.3 *Except*
5-14: 2x4 SP M 30
OTHERS
2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 9=0-8-0
Max Horz 2=-169(LC 8)
Max Uplift 2=-803(LC 10), 9=-803(LC 10)
Max Grav 2=1312(LC 1), 9=1312(LC 1)
6x10 MT18HS =
5x6 =
5x6 =
2x3 11
3x6 =
Scale=1:61.9
CSI.
DEFL.
in (loc) I/deft Ud
PLATES
GRIP
TC 0.81
Vert(LL)
0.69 14 >590 360
MT20
244/190
BC 0.93
Vert(CT)
-0.9214-17 >443 240
MT18HS
244/190
WB 0.86
Horz(CT)
0.34 9 file n/a
Matrix -MS
Weight: 157 lb
FT = 0%
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-5491/3336, 4-5=-5095/3071, 5-6= 2314/1551, 6-8=2398/1533, 8-9=-3199/1981
BOT CHORD 2-14=-3040/5224,13-14=-1195/2361,12-13=-1123/2199,11-12=-1731/3001,
9-11=1731/3001
WEBS 4-14=-492/513, 5-14=-1707/2959, 5-13=405/196, 6-13=-179/522, 8-12=-893/660,
8-11=0/303
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2.4-13, Interior(1) 24-13 to 31-7-3, Exterior(2) 31-7-3
to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing atjoint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
2=803, 9=803.
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
April 3,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev, 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is toprevent buckling of individual truss web and/or chord members only. Addiflonal temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Tmss Type
Ply
M11323
•
T19884599
M11323
A7
SPECIAL
�Qty
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:30 2020 Page 1
ID: W SJgpGwa I Pp eur6hk9 UjGSyu FUL-OIP U nQCcHygOmYBnUkXW ryT1 Fi145CtN9gaVwrzU Ujt
11-0-0, 8-10-10 14-0-0 20-0-0 , 25-11-15 34-0-0 $5.0-q
1-0-0' 8-10-10 5-1-6 6.0-0 5-11-15 8-0-1 -0-0
Ann
3x12 = 2.00 12
LOADING (psf)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
7.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
YES
BCDL
10.0
Code FBC2017/TP12014
LUMBER -
TOP CHORD
2x4 SP M 30
BOT CHORD
2x4 SP M 30
WEBS
2x4 SP No.3 *Except*
4-11: 2x4 SP M 30
REACTIONS. (size) 2=0-8-0, 7=0-8-0
Max Horz 2=-149(LC 8)
Max Uplift 2=-803(LC 10), 7=-803(LC 10)
Max Grav 2=1312(LC 1), 7=1312(LC 1)
5x8 =
5x6 =
lu
5x12 =
20-4-8
20 11
34-0-0
3x6 =
Scale = 1:60.8
CSI.
DEFL.
in (loc) I/deft Ud
PLATES
GRIP
TC 0.83
Vert(LL)
0.66 11 >616 360
MT20
244/190
BC 0.90
Vert(CT)-1.1010-11 >369 240
MT18HS
244/190
WB 0.95
Horz(CT)
0.34 7 n/a n/a
Matrix -MS
Weight: 147 lb
FT = 0%
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc purlins.
BOT CHORD
Rigid ceiling directly applied or 4-0-2 oc bracing.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=5484/3370, 3-4=5116/3126, 4-5=2229/1544, 5-6=2448/1599, 6-7=-3169/1993
BOT CHORD 2-11=-3071/5219, 10-11=-1590/2874, 9-1 0=-1 738/2968, 7-9=-1738/2968
WEBS 3-11=419/443,4-11=-1466/2647,4-10=-812/448,5-10=-205/487, 6-10=-785/575,
6-9=0/272
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf,, h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 31-7-3, Exterior(2) 31-7-3
to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing atjoint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Gt=lb)
2=803,7=803.
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cart6634
6904 Parke East Blvd. Tampa FL 33610
Date:
April 3,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall HT
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiT®k•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPlf Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safely Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
M11323
•
T19884600
M11323
A8
SPECIAL
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 1 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:31 2020 Page 1
ID: WSJgpGwa I Ppeu r6hk9 UjG5yuFUL-Uxzs_mCE2FoFOiI_2R210AOTj6eKgi EW OUJ2SHzUUj s
n1-0-0 8-8-4 12-M 15-8-4 20-4-8 22-0-0 2441 2 34-0-0 a5-0;
h-0-0' 8-8-4 3 3-12 3-8-4 4-8-4 1-7-8 2-8-12 9-3-4 0-0
4.00 12
5x6 =
3x4 =
4 21 5
2x3 11 5x8 =
6 22 7
12 11
3x12 2.00 12
5x12 = 3x4 = 4x5 =
=
LOADING (psf)
SPACING- 2-0-0
CSI.
TCLL 20.0
Plate Grip DOL 1.25
TC 0.78
TCDL 7.0
Lumber DOL 1.25
BC 0.90
BCLL 0.0
Rep Stress Incr YES
WB 0.69
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 9=0-8-0
Max Horz 2=-129(LC 8)
Max Uplift 2=-803(LC 10), 9=-803(LC 10)
Max Grav 2=1312(LC 1), 9=1312(LC 1)
Scale=1:60.6
DEFL.
in (loc)
I/deft
L/d
PLATES
GRIP
Vert(LL)
0.6512-13
>624
360
MT20
244/190
Vert(CT)
-1.08 12-13
>379
240
MT18HS
244/190
Horz(CT)
0.33 9
n/a
n/a
Weight: 154 lb
FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc pudins
BOT CHORD Rigid ceiling directly applied or 3-11-11 oc bracing.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=5488/3444, 3-4=5117/3183, 4-5=-3911/2497, 5-6=-2576/1770, 6-7=-2586/1779,
7-8=-2663/1762,8-9=3021/1971
BOT CHORD 2-13=-3143/5224, 12-13=-1956/3292, 11-12=-1369/2481, 9-11=-1705/2827
WEBS 3-13=396/420, 4-13=1028/1721, 5-13=300/797, 5-12=-894/601, 6-12=-265/263,
7-12=-294/391, 7-11=-374/691, 8-11=-535/502
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 31-7-3, Exterior(2) 31-7-3
to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 2 considers parallel to grain value using ANSIfrPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=803, 9=803.
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Data:
April 3,2020
® WARNING . Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111II-7473 rev, f010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek
fs always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/f Qualify Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314, Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
M11323
•
T19884601
M11323
A9
HIP
1
1
Job Reference (optional)
GnamDers I russ, Inc., Port Pierce, t-L ts.z4u s mar u zuzu MI i ex inausines, Inc. r-n Apr 3 ut:o4:31 LULU rage -I
ID:_etcl cxC3ixW?huls?ypJyuFUK-y7XEC6DspZw6OsKAc9Z_xNZIBW4CZ7Mfd83c?jzUUjr
�1-0-0 6-7-15 10-0-0 15-2-14 20�-0 24-0-0 27-4-1 I _ _34-0-0 35-0-Q
-0-0 6-7-15 3-0-1 5 2-14 5-1-2 3-8-0 3�-1 6-7-15 0-0
4.00 12
4x4 — 3x4 = 2x3 II 4x8 =
4 24 525 26 6 27 7
Scale = 1:58.6
4 14
3x5 = 3x8 = 3x6 = 6x8 = 3x6 = 3x4 = 3x5
34-0-0
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TPI2014
CSI.
TC 0.35
BC 0.54
WB 0.89
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in (loc) I/defl Ltd
-0.18 11-21 >917 360
-0.38 11-21 >432 240
0.02 13 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 156 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 5-11-9 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 9=0-8-0, 13=0-8-0
Max Horz 2=109(LC 9)
Max Uplift 2=-430(LC 10), 9=-249(LC 10), 13=928(LC 10)
Max Grav 2=685(LC 19), 9=386(LC 20), 13=1616(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1275/1025, 3-4=913/708, 4-5=-829/705, 5-6=-565/807, 6-7=-565/807,
7-8=1041278, 8-9=-341/235
BOT CHORD 2-15=-836/1187, 13-15=-34/309, 11-13=-256/348, 9-11=-124/304
WEBS 3-15=-425/501,5-15=444/665,5-13=-1215/1079,6-13=-264/300,7-11=-255/396,
8-11=461/521, 7-13=-837/703
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 5-2-5, Exterior(2) 5-2-5 to
14-9-11, Interior(1) 14-9-11 to 19-2-5, Exterior(2) 19-2-5 to 28-9.11, Interior(1) 28-9-11 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0
zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
'
This item has been
5) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
electronically signed and
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Qt=lb)
sealed by Velez, Joaquin, PE
2=430, 9=249,13=928.
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
April 3,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall �
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing "
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the /giTek•
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
M71323
T19884602
M11323
GRA
HIP
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2U2U MiTeK Industries, Inc. rn Apr 3 Uf:b4:33 [U[U rage 1
ID:_etC1 cxC3ixW?huls?ypJyuFUK-QK4cPSEUat2zdOvM9s4DTb5n5vPvlY6proo9XAzUUjq
�1-0-0 8-0-0 11-1-1 17-M 18-6-0 22-2-2 26 0-0 34-0-0 35 0 q
0-0 B-0-0 3 1-1 5-10-15 1-6-0 3 8-2 3-9-14 8-0-0 1-01'
THIS TRUSS IS NOT SYMMETRIC.
PROPER ORIENTATION IS ESSENTIAL.
4x4 =
Scale = 1:60.6
N
3IA
6
3x5 —_ 3x6 II 3x6 = 6x8 = 3x6 = 6x8 = 4x4 =
6x8 =
TRUSS DESIGNED FOR WIND LOADS IN THE PLANE
OF THE TRUSS ONLY. FOR STUDS EXPOSED TO WIND
(NORMAL TO THE FACE), SEE STANDARD INDUSTRY
GABLE END DETAILS AS APPLICABLE, OR CONSULT
QUALIFIED BUILDING DESIGNER AS PER ANSUTPI 1.
18-6-0 26-0-0
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr NO
Cade FBC2017/TP12014
CSI.
TC 0.91
BC 0.57
WB 0.98
Matrix -MS
DEFL. in (loc) I/deft Ud
Vert(LL) 0.20 24-35 >914 360
Vert(CT) -0.24 29-32 >552 240
Horz(CT) 0.02 22 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 194 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 4-2-5 oc pudins.
BOT CHORD 2x4 SP M 30
Except:
WEBS 2x4 SP No.3
1 Row at midpt 8-21
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
JOINTS 1 Brace at Jt(s): 7, 8, 19, 17, 14
REACTIONS. All bearings 0-8-0.
(lb) - Max Harz 2=-179(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) except 2=-351(LC 8), 27=-1168(LC 8), 26=1495(1_C 8).
22=-625(LC 8)
Max Grav All reactions 250 lb or less at joint(s) except 2=487(LC 17), 27=2232(LC 13), 26=2929(LC 14).
22=984(LC 14)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-621/387, 3-5=-304/838, 5-7=-588/1209, 7-8=-588/1209, 8-12=-588/1209,
12-13=-588/1209, 13-15=-588/1209, 15-16=-588/1209, 16-18=-588/1209,
18-20=-2230/1280, 20-21=-2230/1280, 21-22=-2271/1263, 6-9=-126/305, 9-11=-1061363,
11-14=-1931412, 14-17=-94/271, 19-21 =-1 43/272
BOT CHORD 2-29=247/677, 27-29=-189/540, 26-27=779/446. 24-26=-411/653, 22-24=-108312108
WEBS 3-29=500/1176, 3-27=-1766/911, 5-27=748/622, 5-26=-546/351, 13-26=-946/617,
18-26=-2412/1474, 18-24=-846/1780, 21-24=-35/351, 4-5=608/514, 19-20=335/305,
14-15=-556/407, 11-12=-254/54
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
This item has been
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
electronically signed and
3) Provide adequate drainage to prevent water ponding.
Sealed by Velez, Joaquin, PE
4) All plates are 2x3 MT20 unless otherwise indicated.
using a Digital Signature.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
`
Printed copies of this
6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
document are not Considered
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 351 lb uplift at joint 2, 1168 lb uplift at
signed and sealed and the
joint 27, 1495 lb uplift at joint 26 and 625 Ib uplift at joint 22.
Signature must be verified
8) Girder carries hip end with 8-0-0 end setback.
On any electronic onic C OPI@S.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
Joaquin Velez PE 82
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at
MiTek USA, Inc. FL Cert 634
26-0-0, and 967 lb down and 461 lb up at 8-0-0 on bottom chord. The design/selection of such connection device(s) is the
6904 Parke East Blvd. Tampa FL 33610
responsibility of others.
Date:
11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
April 3,2020
Ifigifi=sManclard
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS9TPI1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
•
T19884602
M11323
GRA
HIP
1
1
�!V!1111323
Job Reference (options[)
Chambers Truss, Inc., Fort Pierce, FL
8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:33 2020 Page 2
ID:_etC1 cxC3ixW?huts?ypJyuFUK-QK4cPSEUat2zdOvM9s4DTb5n5vPvlY6proo9XAzUUjq
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 21-23=54, 29-30=-20, 24-29=47(F=-27), 24-33=-20, 3-11=-126(F=-72), 11-21=-126(F=-72)
Concentrated Loads (lb)
Vert: 29=-641(F) 24=-641(F)
®WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall �
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and properly damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP/i Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
M11323
T19884603
M11323
GRB
HIP
1
1
Job Reference o tionai
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:34 2020 Page 1
ID:SrRaEyyrgO4M78G4raW BLWyuFUJ-uWe7doF7LAApF9UZjacSOoe_iJjP10by4SYi3czUUjp
�1-0-0 8-0-0 13 8-0 17-0-0 1-4-0 26-0-0 34-0-0 $5 0 0
0-0 8-0-0 5-8-0 3 4-0 3-4-0 5-8-0 8-M 0-0
5x121vT18HS = 4x10 =
4.00 12 2x3 II 46 = 2x3 II
3 23 4 5 6 7 24
5x12 MT18HS =
Scale = 1:58.6
4x6 = 3x6 II 5x6 = 6x12 = 6x12 = 5x6 = 3x6 II 4x6 =
LOADING (psf)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
7.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
NO
BCDL
10.0
Code FBC2017/TP12014
LUMBER -
TOP CHORD
2x4 SP M 30
BOT CHORD
2x4 SP M 30
WEBS
2x4 SP No.3 *Except*
4-14,7-13: 2x6 SP No.2
CSI.
DEFL.
in (loc) I/deft Ud
PLATES
GRIP
TC 0.80
Vert(LL)
0.2216-19 >999 360
MT20
244/190
BC 0.68
Vert(CT)-0.3016-19 >820 240
MT18HS
244/190
WB 0.90
Horz(CT)
0.06 9 n/a n/a
Matrix -MS
Weight: 153 lb
FT = 0%
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 3-1-14 oc purlins.
BOT CHORD
Rigid ceiling directly applied or 5-3-14 oc bracing.
WEBS
1 Row at midpt 3-14, 8-13, 6-13
REACTIONS. (size) 2=0-8-0, 13=0-8-0, 9=0-8-0
Max Horz 2=90(LC 7)
Max Uplift 2=-853(LC 8), 13=-2590(LC 8), 9=-345(LC 8)
Max Grav 2=1451(LC 13), 13=4743(LC 15), 9=528(LC 14)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3625/1950, 34=2080/1236, 4-6=-2080/1236, 6-7=-1296/2589, 7-8=-129612589,
8-9=-751 /370
BOT CHORD 2-16=-1729/3460,14-16=-1753/3525,11-13=-262/733,9-11=-241/668
WEBS 3-16=435/1209,3-14=-1552/774,4-14=837/691, 7-13=-878/713,8-13=-3635/1919,
8-11=-432/1204,6-14=145312814,6-13=-3198/1807
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 853 lb uplift at joint 2, 2590 lb uplift at
joint 13 and 345 lb uplift at joint 9.
8) Girder carries hip end with 8-0-0 end setback.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at
26-0-0, and 967 lb down and 461 lb up at 8-0-0 on bottom chord. The design/selection of such connection device(s) is the
responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-8=-131(F=-77), 8-10=-54, 16-17=-20, 11-16=49(F=-29), 11-20=-20
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
April 3,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 4111-7473 rev, 1010312015 BEFORE USE. `
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of Individual truss web andfor chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the AiTe k♦
fabrication, storage, delivery, erection and bracing, of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Ply
M11323
•
T19884603
M11323
GRB
HIP
�Qty
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:35 2020 Page 2
ID:SrRaEyyrg04M78G4raWBLWyu FUJ-MiCNg7Gl6U IgtJ31 H H 7hYOB9Sj3emS r6J6H Gb2zUUjo
LOAD CASE(S) Standard
Concentrated Loads (Ib)
Vert: 16=-641 (F) 11=-641(F)
®WARNING • Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mli-7473 rev. f0/0312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall p ��
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing IV1 iTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP/f Qualfty Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
M11323
•
T19884604
M11323
J2
MONO TRUSS
8
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
3x4 =
LOADING (psf)
SPACING-
2-0-0
CSI.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.18
TCDL
7.0
Lumber DOL
1.25
BC 0.07
BCLL
0.0
Rep Stress Incr
YES
WB 0.00
BCDL
10.0
Code FBC2017/TPI2014
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=67(LC 10)
Max Uplift 3=-28(LC 10), 2=136(LC 10), 4=-3(LC 7)
Max Grav 3=39(LC 15), 2=141(LC 1), 4=31(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:35 2020 Page 1
ID:xl?zSlzTbJCDIIrGPH 1 QukyuFUI-MiCNg7G16UIgtJ31HH7hYOBJ7jCDmgz6J6HGb2zUUjo
2-0-0
Scale = 1:7.8
DEFL. in (loc) I/deft Ud PLATES GRIP
Vert(LL) -0.00 7 >999 360 MT20 244/190
Vert(CT) -0.00 7 >999 240
Horz(CT) -0.00 3 n/a n/a
Weight: 8 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc puriins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 28 lb uplift at joint 3, 136 lb uplift at joint
2 and 3 lb uplift at joint 4.
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cart6634
6904 Parke East Blvd. Tampa FL 33610
Date:
April 3,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall r
buildbuilding design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
ing
required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPH Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke Fast Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty,
Ply
M71323
T19884605
M11323
J4
MONO TRUSS
8
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:36 2020 Page 1
ID:PDYLfd_5MdK4MSQTz?ZfRxyuFUH-qvml2TGNtoQXUTexrtew5DjOW7UmV7DFYm1 p8UzUUjn
-1-0-0 4-0-0
1-0-0 4-0-0
3x4 =
4-0-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.39
Vert(LL)
0.02
4-7
>999
360
TCDL 7.0
Lumber DOL
1.25
BC 0.37
Vert(CT)
-0.02
4-7
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017rrPI2014
Matdx-MP
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=104(LC 10)
Max Uplift 3=-80(LC 10), 2=-161(LC 10), 4=7(LC 10)
Max Grav 3=90(LC 1), 2=207(LC 1), 4=69(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Scale=1:11.1
PLATES GRIP
MT20 244/190
Weight: 14 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc pudins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 80 lb uplift at joint 3, 161 lb uplift at joint
2 and 7 lb uplift at joint 4.
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
April 3,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual buss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabdcation, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Ply
M11323
T19884606'
M11323
J6
MONO TRUSS
�Qty
8
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:36 2020 Page 1
• ID:tP6jt7J7xSx_c_fXi4uz9yuFUG-gvml2TGNtoQXUTexf?ew5DjR?7MUV7DFYmip8UzUUjn
1-0-0 6-M
1-0-0 6-0-0
Scale = 1:14.6
3x4 =
6-0-0
6-M
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deb L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.36
Vert(LL) 0.11
4-7 >629 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.83
Vert(CT) -0.12
4-7 >617 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 20 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purling.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=142(LC 10)
Max Uplift 3=-131(LC 10). 2=-194(LC 10), 4=8(1_C 10)
Max Grav 3=145(LC 1), 2=279(LC 1), 4=102(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131 lb uplift at joint 3, 194 lb uplift at
joint 2 and 8 lb uplift at joint 4.
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
April 3,2020
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED U17EK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracingof trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
M11323
T19884607
M11323
JB
MONO TRUSS
20
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
1-0-0
3x5 =
8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:37 2020 Page 1
I D:1P6jtzJ7xSx_c_fXi4uz9yuFUGJ5K7FpH7d5YO6dD8Oi99eRGYgXquEaTPmQmNgxzUUjm
8-0-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.62
Vert(LL)
0.26
4-7
>367
360
TCDL 7.0
Lumber DOL
1.25
BC 0.38
Vert(CT)
-0.30
4-7
>319
240
BCLL 0.0
Rep Stress Incr
YES
We 0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017frP12014
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 31
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=180(LC 10)
Max Uplift 3=-175(LC 10), 2=-228(LC 10), 4=15(1_C 10)
Max Grav 3=188(LC 1), 2=352(LC 1), 4=145(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Scale=1:17.4
PLATES GRIP
MT20 244/190
Weight: 26 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 3-1-13, Exterjor(2) 3-1-13
to 7-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 175 lb uplift at joint 3, 228 lb uplift at
joint 2 and 15 lb uplift at joint 4.
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
April 3,2020
WARNING • Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall �•
building design. Bracing Indicated is to prevent buckling of individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabdcalion, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
4 -
�MI`1323
T19884608
M11323
KJ8
MONO TRUSS
4
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:38 2020 Page 1
ID:Log54J?LuEancmZr4Qb7 W MyuFUF-nHuVT9ldOPg FknoKyPgOAeooawBGzwZY?4 WwCNzU Ujl
-1`1 7-3-4 11-3-0
1-5 0 7-3-4 3-11-12
Scale=1:20.3
3x4 = 5
3x4 =
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.29
Vert(LL)
0.07
7-10
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.30
Vert(CT)
-0.12
7-10
>999
240
BCLL 0.0
Rep Stress Incr NO
WB 0.46
Horz(CT)
0.02
6
n/a
n/a
BCDL 10.0
Code FBC2017fTP12014
Matrix -MS
Weight: 44 lb FT = 0%
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (size) 4=Mechanical, 2=0-11-5, 6=Mechanical
Max Horz 2=244(LC 8)
Max Uplift 4=-205(LC 8), 2=-305(LC 8), 6=-286(LC 8)
Max Grav 4=245(LC 13), 2=466(LC 1), 6=590(LC 13)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=1151/523
BOT CHORD 2-7=-687/1126, 6-7=-68711126
WEBS 3-7=0/330, 3-6=-1236/755
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins.
BOT CHORD Rigid ceiling directly applied or 8-9-6 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 205 lb uplift at joint 4, 305 lb uplift at
joint 2 and 286 lb uplift at joint 6.
6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
This item has been
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1-25
electronically signed and
Uniform Loads (plf)
sealed by Velez, Joaquin, PE
Vert: 1-2=-54
Trapezoidal Loads (plf)
using a Digital Signature.
Vert: 2=0(F=27, B=27)-to-4=-152(F=-49, B=-49), 8=0(F=10, B=10)-to-5=-56(F=-18, B=-18)
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
April 3,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall Ar
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing IV1iTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPH Quality Criferla, DSE-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Symbols
PLATE LOCATION AND ORIENTATION
14-1 3/4' Center plate on joint unless x, y
offsets are indicated.
Dimensions are in ft-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
OA,e.
-
-I-
For 4 x 2 orientation, locate
plates 0- yis" from outside
edge of truss.
This symbol indicates the
required direction of slots in
connector plates.
Plate location details available in MiTek 20120
software or upon request.
PLATE SIZE
The first dimension is the plate
4 x 4 width measured perpendicular
to slots. Second dimension is
the length parallel to slots.
r
LATERAL BRACING LOCATION
Indicated by symbol shown and/or
by text in the bracing section of the
output. Use T or I bracing
if indicated.
BEARING
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
Min size shown is for crushing only.
Industry Standards:
ANSIITP11: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
BCSI: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
Numbering System
6-4-8 dimensions shown in ft-in-sixteenths
(Drawings not to scale)
A General Safety Notes
Failure to Follow Could Cause Property
Damage or Personal Injury
1
2 3
1. Additional stability bracing for truss system, e.g.
TOP CHORDS
diagonal or X-bracing, is always required. See SCSI.
c1-2 c2-3
2. Truss bracing must be designed by an engineer. For
4
wide truss spacing, individual lateral braces themselves -
O
WEBS
S
may require bracing, or alternative Tor I
�'•�
p
bracing should be considered.
O
2
U
3 ��a
3
cY
O
3. Never exceed the design loading shown and never
4
�
U
stack materials on inadequately braced trusses.
d
Oc7-e
O
4. Provide copies of this truss design to the building
cs r c5-6 1
I—
designer, erection supervisor, property owner and
BOTTOM CHORDS
all other interested parties.
8
7 6 5
5. Cut members to bear tightly against each other.
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
PRODUCT CODE APPROVALS
ICC-ES Reports:
ESR-1311, ESR-1352, ESR1988
ER-3907, ESR-2362, ESR-1397, ESR-3282
Trusses are designed for wind loads in the plane of the
truss unless otherwise shown.
Lumber design values are in accordance with ANSI/TPI 1
section 6.3 These truss designs rely on lumber values
established by others.
© 2012 MiTek® All Rights Reserved
!All
MiTek®
MiTek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015
6. Place plates on each face of truss at each
joint and embed fully. Knots and wane at joint
locations are regulated by ANSI/TPI 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSI/TPI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19% at time of fabrication.
9. Unless expressly noted, this design is not applicable for
use with fire retardant, preservative treated, or green lumber.
10. Camber is a non-structural consideration and is the
responsibility of truss fabricator. General practice is to
camber for dead load deflection.
11. Plate type, size, orientation and location dimensions
indicated are minimum plating requirements.
12. Lumber used shall be of the species and size, and
in all respects, equal to or better than that
specified.
13. Top chords must be sheathed or pur ins provided at
spacing indicated on design.
14. Bottom chords require lateral bracing at 10 ft. spacing,
or less, if no ceiling is installed, unless otherwise noted.
15. Connections not shown are the responsibility of others.
16. Do not cut or alter truss member or plate without prior
approval of an engineer.
17. Install and load vertically unless indicated otherwise.
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front, back, words
and pictures) before use. Reviewing pictures alone
is not sufficient.
20. Design assumes manufacture in accordance with
ANSI/TPI 1 Quality Criteria.