HomeMy WebLinkAboutTruss;j I I I� I A -LIFE SAFETY WARNING This symbol identifies Life Safety Warnings that should be read given special attention by all persons installing trusses. 5PAGING NOTE ALL TRUSSES ARE TO BE 5ET AT 2.-Oz ON CENTER' EXGEPT A5 NOTED l� MULTIPLE PLY TRUSSES MUST BE ASTENED TOGETHER PER ENGINEERIN BEFORE SETTING. REFER TO ENGINEERING DRAWING TO DETERMINE A IF MULTIPLE PLY. i DON'T LIFT TRUSSES WITH SPANS LONGER THAN 30' BY THE PEAK. CONSULT BCSI 30' Span or less ® 30' to 60' Span 60 degrees Spree er Bar or less 1 2 09 F—APProz 2/3 to / Line 1/2-of Span Tog Line span approx. BCSI REFER TO BCSI REFER TO TTruss must be set this way if crane used. Truss must be set this way if crane used. This is an example, truss may not match. Trussis on example, your truss may not match. Insist crane operator sets truss this way. Insist crane operator sets truss this way. j i a lit s AIR HANC7LIE=F? NOT Ill UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS. CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR. f U REPRESENTS A HANGER Carrying Girder For Truss to Truss Connections see hanger/connector Nails must be as shown. Guide tabs o schedule In engineering Dome angle fills. package. Carried Truss SEAT PLATES BY CHAMBERS INDICATES LOAD BEARING WALL REQUIRED BY TRUSSES SUPPLIED BY BUILDER AT A HEIGHT OF 8'-1" ABOVE FINISHED FLOOR 12 4.00 08-1 upset=1J4'• heel=315/16" PLUMB CUT END 1, 2 x 4 Top Chord WALL HEIGHT ll TYPICAL END DETAIL 12 4.00 I .00000 12 2.00 8-1 upset=l/4" heel=315/16" PLUMB CUT END 2 x 4 Top Chord WALL HEIGHT III END DETAIL: A ® ARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF 171- 231 IN Lwess .NGTH - - ® Do not stand on trusses until they are braced per BCSI & properly nailed to straps & hangers Ea aBR��aT,oNgGREEMENT sw 20, 14' 6-4- TI 9'-6- — - — — — 34 GARAGE, LEFT NOT ft STARTED UNTIL a tr AGREEMENT IS SIGNED & RETURNED r The, lapel description Of the property where the trusses will be Installed is: The underalgned ecknowletlgea end agrees: 1: Trusses will be made In smct accordance w —`— whlch b fh0 sole atrlh10ry for detarmininpsucceasrul ab canon of a trmussne �aprem layout, 2. All dimensions h this layout have bean venfied by the undersigned. 34' 3. Unless written hall Is provided by csHfied mall to Chambe a 7 ties Within ten (10) days of delivery the undersigned agrees that no backchargas will be ellowe Wih the event such wnuen not la furnished Cha mere Trues shall have three 3 busJnass day$ In which 20' 14' to beglo repairs rgequlred, or to subsu a other Wssea, aChamben)opu$n.' 4. The e I sl ned acknowledpas receipt of "BCSI 1-03"summary sheet by'rPl & yv7gq, 'S, Delivery la to Job site. It la the buyars'reaponalbiury to make the Job slle suitable for delivery,of Chambers Thum has the sots authority to determine the suitability or th Job site o} a Portion buyer Is Job site for delivery, Chambers Truss will be responsible /or dump delivery only. The buyer la responsible for additional delivery expenses If Chambers Truss has to redeliver because Job site is dot prepared for delivery or buyer Ia not prepared for delivery of trusses, Buyer Is responsible to Chambers Trues for towing wale duo to sue conditions. S. Price as shown Iq paregraph 7 below Is subJeclto change If any ehangea are. made In this. leyOUL A $50 per hour fee for revisions may be change e If an T 7; Thin Is a PURC ��Will l®'®Ir I®I®I® Lq ro Is VA 1 100 II 001101 �J 11010 IPA 110 �11010_ NilElEpp .100 011 11011 1110m lop, CIA PO PFO r 0 _114 • % rr i%////fit//%r / fr �/� �/////I//ii�/�riZZA01 '' �� //.li// i�,/,li////li///�i�//!✓ • . RASE ORDER to Chambers, Truss of the sum agreed to, or If nq agreement a reasonable price. Invoice will be made on delivery and paid within terms of net on delivery. Invoice may be made at scheduled date of delivery If buyer cannot accept delivery of fabricated bu$sea, Tha undersigned agrees to pay unambers,7ryss reasonable charge fee for wlleClbns In evert of payment not timely made. 1.12 %per month servJce charge will be added for all sums not pal, within terms. S. Signature or Initials anywhere on this sheet wnslltutas agreement to all terms herein, 9, In consideration of Chambers Truss eMending credit for this material the undersigned ' unwndl0onally guarantees payment when due of any and all Indebtedness owed to Chembere Truss by any entity receiving material and the undersigned agrees to pay such Indebtedness Including adomeye fees, If default in payment for material be made by tire recipient.- . 10. In the event of any litigation concerning this agreement, the Items fumished hereunder be payments referred to herein, the, parlorida t agree that the sole venue for any such action will be Saint Payments r County, herein 11. Design responsibllitles are per "National Standard And Recommended Guidelines On Responsibilities For Construction Using Metal Plate Connected Wood Trusses ANSI/rIal/WTCA 4.2002 DATED . SIGNED - FOR TITLE -- --- —�- Aspreaderbarmay be re9tLued POr "BCSI 1-03" 4� pmygnt Ir#ury& darnMge = Multiple ply trusses must be fastened together per engineering before they are set, failure to do so can resulit in roof collapgo, Temporary and permanent bracing are required and can save life and property and is the resPonslblllty of the truss erector. Study the contents of the information packet Included on delivery before setting trusses. Thames must be astaW braced Perdssign 6 Pint �w Y& damage, Trusses must be set plumb and square Do not sat bunks or stack of plywood, roofing material or any other concentrated loads on trusses, this Can cause collapse. D0 NOT SE'T TRUSSES USING TMIS LA p(7 USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES CF1�MBERS TRUSS INC I_. 3105 Oleander Avenue Fort Pierce; Flollda 34982-6423 800-551.5932 Fort Pierce 772-465.2012 Fax 772-465-8711 Vero Beach 772-569-2012 Stuart 772-2863302 ' The Architect's or Architect's representative's shop drawing approval is NOT a "double check" of the. Contractor. The contractor shall remaro responsible for checking field measurements and other construction criteria. Architect's approval covers genera! roof shape,:, review of truss strapping, and loading on structure ifram gravity a`ntl Uplift Ida and their resp !ye lacdtio s. Approved Ely: Date __ 92.0/93.2 MITEK 4.2 Braden den A,1.A P.A. DESIGN CRITERIA County SAINT LUCIE Building Department SAINT LUCIE COUNTY Wind Design Criteria ASCE 7-2010 3 0 (k) Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-10 b (Roofing Material Shingle or Shake e�IN Loading in PSF Roof R.D.L. H o Top Chord Live 20 w,I Top Chord Dead 7 4.2 /l Bottom Chord Live 10 Non -Concurrent ° Bottom Chord Dead 10 3 m c� � I TOTAL Load 37 7.2 R o M Duration Factor 1.25 R Wind Speed 165mph y w Top Chord C.B. Sheeting by builder. Bottom Chord C.B. Sheeting by builder. Highest Mean Height 14'-0" Building Type ENCLOSED Building Category II:Non Restrictive Exposure Category C Barrier Island No Conforms to FBC 2017 R.D.L =Restrainin Dead Load C.B.=Continuous Bracing Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of the Buildin Desi ner and/or Engineer of Record. Chambers Truss Inc. Drawing Name. M11 3 land Scale: 1 /4 = 1' F11 72 total trusses, 13 different trusses. alls MI 4: SAE ACAD: SAE Reviewed By: if / Date: 04/24/12 Revised: 02/21/18 FOR Revised: 3/05/?0 OR Q NE BUILDII i3 PLIANCE _ ` DESCRIPTION:---ST. LUCIE COUNTY GARAGE RIGHT CARLTON BOCC PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE 13 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT M11323 1'W7 MiTek RE: M11323 MiTek USA, Inc. M11323 6904 Parke East Blvd. Tampa, FL 33610-4115 Site Information: Customer: WYNNNE DEVELOPEMENT CORP Project Name: M11323 Lot/Block: Model: CARLTON Address: N/A Subdivision: City: PORT ST LUCIE State: FL General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 165 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 13 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date 1 T1988459 A 6/25/2020 2 T19884597 A5 6/25/2020 FILE 3 T19884598 A6 6/25/2020 4 T19884599 A7 6/25/2020 5 T19884600 A8 6/25/2020 6 T19884601 A9 6/25/2020 REVIEWED FAIR 8 9 T19884603 T19884604 GRB J2 6/25/2020 6/25/2020 ����®IlIIPLIAtfVCE 10 11 T19884605 T19884606 J4 J6 6/25/2020 6/25/2020 w� 7T Y �. UCIE COUNT ST. 12 T19884607 J8 6/25/2020 p� 13 T19884608 KJ8 6/25/2020 ROM This item has been electronically signed and sealed by Velez, Joaquin using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies The truss drawing(s) referenced above have been prepared by MiTek USA, Inc under my direct supervision ,`,t,ttt1111rrI,�,, based on the parameters provided by Chambers Truss. `,��OPQU1 N Truss Design Engineer's Name: Velez, Joaquin � �.,��G�E NS�,.� My license renewal date for the state of Florida is February 28, 2021. Florida COA: 6634 No 68182 IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdictions) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. -33: STATE OF 4 O R 10 P `_`�� ���s`S�O N AL E����• ,���11111111tt�� Joaquin Velez PE No.68182 MITek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 June 25, 2020 1 of 1 Velez, Joaquin Job Truss Truss Type Ply M11323 r �Qty T19884596 M11323 A COMMON 9 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:64:27 2020 ID:a3B4PavKnnZweXyJckSFBgyuFUN-bAjL909k 1Hpv5SDpc_pEKrtnVLQuvtwTlLrJN 11-0-0. 6-7-13 12-4-13 17-0-0 21-7-3 27.4-3 34-0-0 �1 6 3x6 = 4.00 12 4x5 = 27 17 15 14 "' 12 2x3 II 4x6 = 3x8 = 3x8 = 4x6 2x3 II Scale = 1:57.8 3x6 = 6-7-13 12.4-13 21-7-3 271-3 34-0-0 6-7-13 5-9-0 9-2-7 5-9-0 6-7-13 Plate Offsets (X,Y)— [2:0-0-2,Edge), [10:0-0-2,Edge) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.39 Vert(LL) 0.32 14-15 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.58 Verl(CT) -0.61 14-15 >670 240 BCLL 0.0 Rep Stress Incr YES WB 0.65 Horz(CT) 0.12 10 n/a n/a BCDL 10.0 Code FBC2017frP12014 Matrix -MS Weight: 163 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD BOT CHORD 2x4 SP M 30 BOT CHORD WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-179(LC 8) Max Uplift 2=-832(LC 10). 10=-832(LC 10) Max Grav 2=1362(LC 1), 10=1362(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=3419/2395, 3-5=-2771/2031, 5.6=-2770/2152, 6-7=-2770/2152, 7-9=2771/2031, 9-10=3419/2395 BOT CHORD 2-17=-2132/3213,15-17=-2132/3213,14-15=-1269/2000,12-14=-2132/3213, 10-12=-2132/3213 WEBS 6-14=635/983, 7-14=-313/362, 9-14=-689/499, 6-15=-635/983, 5-15=-313/362, 3-15=-689/499 Structural wood sheathing directly applied or 3-7-12 oc purlins. Rigid ceiling directly applied or 4-11-7 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 13-7-3, Extedor(2) 13-7-3 to 20-1-13, Intenor(1) 20-4-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. This item has been 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL=10.Opsf. electronically signed and 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except (jt=1b) sealed by Velez, Joaquin, PE 2=832, 10=832. using a Digital Signature. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 50 lb down and 47 lb up at Printed copies of this 15-0-0, and 50 lb down and 47 lb up at 19-0-0 on top chord. The design/selection of such connection device(s) is the responsibility of others. document are not considered 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). Signed and Sealed and the signature must be verified LOAD CASE(S) Standard on any electronic copies. 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Joaquin Velez PE No.68182 Uniform Loads (pif) Vert: 6-11=-54, 18-21=-20 MiTek USA, Inc. FL Cart 6634 Loads (l Concentrated Loads (Ib) 6904 Parke East Blvd. Tampa FL 33610 Vert: 26=-50(F) 27=-50(F) Date: April 3,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,111-7473 rev. f0/03/2015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall building design. Bracing indicatedis to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. Forgenerai guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Ply T19884597 M11323 A5 SPECIAL �Qty 9 1 �M11323 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:28 2020 Page 1 ID:2GIScwwyY5hnGhXVARzUkuyuFUM-3MHjMkAMIKQgXE1 PNJV2mXOxRucedNo4iX50ryzUUjv 1-0-0 7-8-5 1% 4 17-0-0 20-4-8 264-0 34-0-0 5-0- 0-0 7-8-5 2-9-15 6-5-12 34 8 5 11 8 7-8-0 -0-0 5x8 MT18HS 11 4.00 12 Scale = 1:59.8 13 12 5x12 = 2x3 II 3x6 = 3x12 = 2.00 12 10.6.4 204-8 i264-0 34-0-0 ' 10-6-4 9-10-4 5-11-a 7-8-0 Plate Offsets_(X,Y)— [2:0-1 -15, Edge], [4:0-3-0,Edge], [10:0-0-6,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.85 Vert(LL) 0.76 14 >539 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.90 Vert(CT) -1.18 13-14 >344 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.60 Horz(CT) 0.38 10 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MS Weight: 155 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 1-7-8 cc puriins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 3-9-12 cc bracing. WEBS 2x4 SP No.3 *Except* WEBS 1 Row at midpt 6-14 6-14: 2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-179(LC 8) Max Uplift 2=-803(LC 10), 10=-803(LC 10) Max Grav 2=1312(LC 1), 10=1312(LC 1) FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=5529/3776, 3-5=-5164/3538, 5-6=-5209/3667, 6-7=-2424/1902, 7-9=-2462/1813, 9-10=-3195/2210 BOT CHORD 2-14=-3466/5266, 13-14=-1305/2115, 12-13=-1948/2995, 10-12=-1948/2995 WEBS 3-14=-355/314, 5-14=-293/354, 6-14=-2175/3326, 6-13=-279/534, 7-13=-237/277, 9-13=786/560, 9-12=0/269 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; save=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 24-13, Interior(1) 24-13 to 13-7-3, Exterior(2) 13-7-3 to 20-64, Interior(1) 20-6-4 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. This Item has been 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. electronically signed and 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide sealed by Velez, Joaquin, PE will fit between the bottom chord and any other members. using a Digital Signature. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify Printed Copies of this capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) document are not considered 2=803,10=803. signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. f010312015 BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIyTPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Ply M11323 T19884598 M11323 A6 SPECIAL �Qty 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:29 2020 Page 1 ID:2GIScwwyY5hnGhXVARzU kuyu FUM-YYr6a4B_WeYX90cbw00HJlx7ilyP Mm6 DxB gy00zU Uju �1-0-0 8-11-11 16-0-0 18-0-0 20-4 8 25-11-15 , 34-0-0 35-0-q -0-0 8-11-11 7-0-5 2-0-0 2-4-8 5 7-7 8-0-1 0-0 4.00 12 3x12 = 2.00 12 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017/TPI2014 LUMBER - TOP CHORD 2x4 SP M 30'ExcepV 3-5,6-7: 2x4 SP M 31 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* 5-14: 2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-169(LC 8) Max Uplift 2=-803(LC 10), 9=-803(LC 10) Max Grav 2=1312(LC 1), 9=1312(LC 1) 6x10 MT18HS = 5x6 = 5x6 = 2x3 11 3x6 = Scale=1:61.9 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TC 0.81 Vert(LL) 0.69 14 >590 360 MT20 244/190 BC 0.93 Vert(CT) -0.9214-17 >443 240 MT18HS 244/190 WB 0.86 Horz(CT) 0.34 9 file n/a Matrix -MS Weight: 157 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-5491/3336, 4-5=-5095/3071, 5-6= 2314/1551, 6-8=2398/1533, 8-9=-3199/1981 BOT CHORD 2-14=-3040/5224,13-14=-1195/2361,12-13=-1123/2199,11-12=-1731/3001, 9-11=1731/3001 WEBS 4-14=-492/513, 5-14=-1707/2959, 5-13=405/196, 6-13=-179/522, 8-12=-893/660, 8-11=0/303 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2.4-13, Interior(1) 24-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing atjoint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=803, 9=803. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev, 1010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is toprevent buckling of individual truss web and/or chord members only. Addiflonal temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Tmss Type Ply M11323 • T19884599 M11323 A7 SPECIAL �Qty 1 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:30 2020 Page 1 ID: W SJgpGwa I Pp eur6hk9 UjGSyu FUL-OIP U nQCcHygOmYBnUkXW ryT1 Fi145CtN9gaVwrzU Ujt 11-0-0, 8-10-10 14-0-0 20-0-0 , 25-11-15 34-0-0 $5.0-q 1-0-0' 8-10-10 5-1-6 6.0-0 5-11-15 8-0-1 -0-0 Ann 3x12 = 2.00 12 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017/TP12014 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* 4-11: 2x4 SP M 30 REACTIONS. (size) 2=0-8-0, 7=0-8-0 Max Horz 2=-149(LC 8) Max Uplift 2=-803(LC 10), 7=-803(LC 10) Max Grav 2=1312(LC 1), 7=1312(LC 1) 5x8 = 5x6 = lu 5x12 = 20-4-8 20 11 34-0-0 3x6 = Scale = 1:60.8 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TC 0.83 Vert(LL) 0.66 11 >616 360 MT20 244/190 BC 0.90 Vert(CT)-1.1010-11 >369 240 MT18HS 244/190 WB 0.95 Horz(CT) 0.34 7 n/a n/a Matrix -MS Weight: 147 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-0-2 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=5484/3370, 3-4=5116/3126, 4-5=2229/1544, 5-6=2448/1599, 6-7=-3169/1993 BOT CHORD 2-11=-3071/5219, 10-11=-1590/2874, 9-1 0=-1 738/2968, 7-9=-1738/2968 WEBS 3-11=419/443,4-11=-1466/2647,4-10=-812/448,5-10=-205/487, 6-10=-785/575, 6-9=0/272 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf,, h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing atjoint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Gt=lb) 2=803,7=803. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall HT building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiT®k• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPlf Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safely Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type City Ply M11323 • T19884600 M11323 A8 SPECIAL 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 1 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:31 2020 Page 1 ID: WSJgpGwa I Ppeu r6hk9 UjG5yuFUL-Uxzs_mCE2FoFOiI_2R210AOTj6eKgi EW OUJ2SHzUUj s n1-0-0 8-8-4 12-M 15-8-4 20-4-8 22-0-0 2441 2 34-0-0 a5-0; h-0-0' 8-8-4 3 3-12 3-8-4 4-8-4 1-7-8 2-8-12 9-3-4 0-0 4.00 12 5x6 = 3x4 = 4 21 5 2x3 11 5x8 = 6 22 7 12 11 3x12 2.00 12 5x12 = 3x4 = 4x5 = = LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.78 TCDL 7.0 Lumber DOL 1.25 BC 0.90 BCLL 0.0 Rep Stress Incr YES WB 0.69 BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-129(LC 8) Max Uplift 2=-803(LC 10), 9=-803(LC 10) Max Grav 2=1312(LC 1), 9=1312(LC 1) Scale=1:60.6 DEFL. in (loc) I/deft L/d PLATES GRIP Vert(LL) 0.6512-13 >624 360 MT20 244/190 Vert(CT) -1.08 12-13 >379 240 MT18HS 244/190 Horz(CT) 0.33 9 n/a n/a Weight: 154 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc pudins BOT CHORD Rigid ceiling directly applied or 3-11-11 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=5488/3444, 3-4=5117/3183, 4-5=-3911/2497, 5-6=-2576/1770, 6-7=-2586/1779, 7-8=-2663/1762,8-9=3021/1971 BOT CHORD 2-13=-3143/5224, 12-13=-1956/3292, 11-12=-1369/2481, 9-11=-1705/2827 WEBS 3-13=396/420, 4-13=1028/1721, 5-13=300/797, 5-12=-894/601, 6-12=-265/263, 7-12=-294/391, 7-11=-374/691, 8-11=-535/502 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2 considers parallel to grain value using ANSIfrPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=803, 9=803. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Data: April 3,2020 ® WARNING . Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111II-7473 rev, f010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek fs always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/f Qualify Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314, Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 • T19884601 M11323 A9 HIP 1 1 Job Reference (optional) GnamDers I russ, Inc., Port Pierce, t-L ts.z4u s mar u zuzu MI i ex inausines, Inc. r-n Apr 3 ut:o4:31 LULU rage -I ID:_etcl cxC3ixW?huls?ypJyuFUK-y7XEC6DspZw6OsKAc9Z_xNZIBW4CZ7Mfd83c?jzUUjr �1-0-0 6-7-15 10-0-0 15-2-14 20�-0 24-0-0 27-4-1 I _ _34-0-0 35-0-Q -0-0 6-7-15 3-0-1 5 2-14 5-1-2 3-8-0 3�-1 6-7-15 0-0 4.00 12 4x4 — 3x4 = 2x3 II 4x8 = 4 24 525 26 6 27 7 Scale = 1:58.6 4 14 3x5 = 3x8 = 3x6 = 6x8 = 3x6 = 3x4 = 3x5 34-0-0 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017/TPI2014 CSI. TC 0.35 BC 0.54 WB 0.89 Matrix -MS DEFL. Vert(LL) Vert(CT) Horz(CT) in (loc) I/defl Ltd -0.18 11-21 >917 360 -0.38 11-21 >432 240 0.02 13 n/a n/a PLATES GRIP MT20 244/190 Weight: 156 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-11-9 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0, 13=0-8-0 Max Horz 2=109(LC 9) Max Uplift 2=-430(LC 10), 9=-249(LC 10), 13=928(LC 10) Max Grav 2=685(LC 19), 9=386(LC 20), 13=1616(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1275/1025, 3-4=913/708, 4-5=-829/705, 5-6=-565/807, 6-7=-565/807, 7-8=1041278, 8-9=-341/235 BOT CHORD 2-15=-836/1187, 13-15=-34/309, 11-13=-256/348, 9-11=-124/304 WEBS 3-15=-425/501,5-15=444/665,5-13=-1215/1079,6-13=-264/300,7-11=-255/396, 8-11=461/521, 7-13=-837/703 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 5-2-5, Exterior(2) 5-2-5 to 14-9-11, Interior(1) 14-9-11 to 19-2-5, Exterior(2) 19-2-5 to 28-9.11, Interior(1) 28-9-11 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ' This item has been 5) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. electronically signed and 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Qt=lb) sealed by Velez, Joaquin, PE 2=430, 9=249,13=928. using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall � building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing " is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the /giTek• fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314. Tampa, FL 36610 Job Truss Truss Type City Ply M71323 T19884602 M11323 GRA HIP 1 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2U2U MiTeK Industries, Inc. rn Apr 3 Uf:b4:33 [U[U rage 1 ID:_etC1 cxC3ixW?huls?ypJyuFUK-QK4cPSEUat2zdOvM9s4DTb5n5vPvlY6proo9XAzUUjq �1-0-0 8-0-0 11-1-1 17-M 18-6-0 22-2-2 26 0-0 34-0-0 35 0 q 0-0 B-0-0 3 1-1 5-10-15 1-6-0 3 8-2 3-9-14 8-0-0 1-01' THIS TRUSS IS NOT SYMMETRIC. PROPER ORIENTATION IS ESSENTIAL. 4x4 = Scale = 1:60.6 N 3IA 6 3x5 —_ 3x6 II 3x6 = 6x8 = 3x6 = 6x8 = 4x4 = 6x8 = TRUSS DESIGNED FOR WIND LOADS IN THE PLANE OF THE TRUSS ONLY. FOR STUDS EXPOSED TO WIND (NORMAL TO THE FACE), SEE STANDARD INDUSTRY GABLE END DETAILS AS APPLICABLE, OR CONSULT QUALIFIED BUILDING DESIGNER AS PER ANSUTPI 1. 18-6-0 26-0-0 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Cade FBC2017/TP12014 CSI. TC 0.91 BC 0.57 WB 0.98 Matrix -MS DEFL. in (loc) I/deft Ud Vert(LL) 0.20 24-35 >914 360 Vert(CT) -0.24 29-32 >552 240 Horz(CT) 0.02 22 n/a n/a PLATES GRIP MT20 244/190 Weight: 194 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 4-2-5 oc pudins. BOT CHORD 2x4 SP M 30 Except: WEBS 2x4 SP No.3 1 Row at midpt 8-21 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 7, 8, 19, 17, 14 REACTIONS. All bearings 0-8-0. (lb) - Max Harz 2=-179(LC 6) Max Uplift All uplift 100 lb or less at joint(s) except 2=-351(LC 8), 27=-1168(LC 8), 26=1495(1_C 8). 22=-625(LC 8) Max Grav All reactions 250 lb or less at joint(s) except 2=487(LC 17), 27=2232(LC 13), 26=2929(LC 14). 22=984(LC 14) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-621/387, 3-5=-304/838, 5-7=-588/1209, 7-8=-588/1209, 8-12=-588/1209, 12-13=-588/1209, 13-15=-588/1209, 15-16=-588/1209, 16-18=-588/1209, 18-20=-2230/1280, 20-21=-2230/1280, 21-22=-2271/1263, 6-9=-126/305, 9-11=-1061363, 11-14=-1931412, 14-17=-94/271, 19-21 =-1 43/272 BOT CHORD 2-29=247/677, 27-29=-189/540, 26-27=779/446. 24-26=-411/653, 22-24=-108312108 WEBS 3-29=500/1176, 3-27=-1766/911, 5-27=748/622, 5-26=-546/351, 13-26=-946/617, 18-26=-2412/1474, 18-24=-846/1780, 21-24=-35/351, 4-5=608/514, 19-20=335/305, 14-15=-556/407, 11-12=-254/54 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. This item has been II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 electronically signed and 3) Provide adequate drainage to prevent water ponding. Sealed by Velez, Joaquin, PE 4) All plates are 2x3 MT20 unless otherwise indicated. using a Digital Signature. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ` Printed copies of this 6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. document are not Considered 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 351 lb uplift at joint 2, 1168 lb uplift at signed and sealed and the joint 27, 1495 lb uplift at joint 26 and 625 Ib uplift at joint 22. Signature must be verified 8) Girder carries hip end with 8-0-0 end setback. On any electronic onic C OPI@S. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Joaquin Velez PE 82 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at MiTek USA, Inc. FL Cert 634 26-0-0, and 967 lb down and 461 lb up at 8-0-0 on bottom chord. The design/selection of such connection device(s) is the 6904 Parke East Blvd. Tampa FL 33610 responsibility of others. Date: 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). April 3,2020 Ifigifi=sManclard ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS9TPI1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type City Ply • T19884602 M11323 GRA HIP 1 1 �!V!1111323 Job Reference (options[) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:33 2020 Page 2 ID:_etC1 cxC3ixW?huts?ypJyuFUK-QK4cPSEUat2zdOvM9s4DTb5n5vPvlY6proo9XAzUUjq LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 21-23=54, 29-30=-20, 24-29=47(F=-27), 24-33=-20, 3-11=-126(F=-72), 11-21=-126(F=-72) Concentrated Loads (lb) Vert: 29=-641(F) 24=-641(F) ®WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall � building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and properly damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP/i Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 T19884603 M11323 GRB HIP 1 1 Job Reference o tionai Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:34 2020 Page 1 ID:SrRaEyyrgO4M78G4raW BLWyuFUJ-uWe7doF7LAApF9UZjacSOoe_iJjP10by4SYi3czUUjp �1-0-0 8-0-0 13 8-0 17-0-0 1-4-0 26-0-0 34-0-0 $5 0 0 0-0 8-0-0 5-8-0 3 4-0 3-4-0 5-8-0 8-M 0-0 5x121vT18HS = 4x10 = 4.00 12 2x3 II 46 = 2x3 II 3 23 4 5 6 7 24 5x12 MT18HS = Scale = 1:58.6 4x6 = 3x6 II 5x6 = 6x12 = 6x12 = 5x6 = 3x6 II 4x6 = LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr NO BCDL 10.0 Code FBC2017/TP12014 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* 4-14,7-13: 2x6 SP No.2 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TC 0.80 Vert(LL) 0.2216-19 >999 360 MT20 244/190 BC 0.68 Vert(CT)-0.3016-19 >820 240 MT18HS 244/190 WB 0.90 Horz(CT) 0.06 9 n/a n/a Matrix -MS Weight: 153 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-1-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 5-3-14 oc bracing. WEBS 1 Row at midpt 3-14, 8-13, 6-13 REACTIONS. (size) 2=0-8-0, 13=0-8-0, 9=0-8-0 Max Horz 2=90(LC 7) Max Uplift 2=-853(LC 8), 13=-2590(LC 8), 9=-345(LC 8) Max Grav 2=1451(LC 13), 13=4743(LC 15), 9=528(LC 14) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3625/1950, 34=2080/1236, 4-6=-2080/1236, 6-7=-1296/2589, 7-8=-129612589, 8-9=-751 /370 BOT CHORD 2-16=-1729/3460,14-16=-1753/3525,11-13=-262/733,9-11=-241/668 WEBS 3-16=435/1209,3-14=-1552/774,4-14=837/691, 7-13=-878/713,8-13=-3635/1919, 8-11=-432/1204,6-14=145312814,6-13=-3198/1807 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 853 lb uplift at joint 2, 2590 lb uplift at joint 13 and 345 lb uplift at joint 9. 8) Girder carries hip end with 8-0-0 end setback. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at 26-0-0, and 967 lb down and 461 lb up at 8-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-8=-131(F=-77), 8-10=-54, 16-17=-20, 11-16=49(F=-29), 11-20=-20 This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 4111-7473 rev, 1010312015 BEFORE USE. ` Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of Individual truss web andfor chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the AiTe k♦ fabrication, storage, delivery, erection and bracing, of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Ply M11323 • T19884603 M11323 GRB HIP �Qty 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:35 2020 Page 2 ID:SrRaEyyrg04M78G4raWBLWyu FUJ-MiCNg7Gl6U IgtJ31 H H 7hYOB9Sj3emS r6J6H Gb2zUUjo LOAD CASE(S) Standard Concentrated Loads (Ib) Vert: 16=-641 (F) 11=-641(F) ®WARNING • Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mli-7473 rev. f0/0312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall p �� building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing IV1 iTek• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP/f Qualfty Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 • T19884604 M11323 J2 MONO TRUSS 8 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 TCDL 7.0 Lumber DOL 1.25 BC 0.07 BCLL 0.0 Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=67(LC 10) Max Uplift 3=-28(LC 10), 2=136(LC 10), 4=-3(LC 7) Max Grav 3=39(LC 15), 2=141(LC 1), 4=31(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:35 2020 Page 1 ID:xl?zSlzTbJCDIIrGPH 1 QukyuFUI-MiCNg7G16UIgtJ31HH7hYOBJ7jCDmgz6J6HGb2zUUjo 2-0-0 Scale = 1:7.8 DEFL. in (loc) I/deft Ud PLATES GRIP Vert(LL) -0.00 7 >999 360 MT20 244/190 Vert(CT) -0.00 7 >999 240 Horz(CT) -0.00 3 n/a n/a Weight: 8 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc puriins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 28 lb uplift at joint 3, 136 lb uplift at joint 2 and 3 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall r buildbuilding design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* ing required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPH Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke Fast Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty, Ply M71323 T19884605 M11323 J4 MONO TRUSS 8 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:36 2020 Page 1 ID:PDYLfd_5MdK4MSQTz?ZfRxyuFUH-qvml2TGNtoQXUTexrtew5DjOW7UmV7DFYm1 p8UzUUjn -1-0-0 4-0-0 1-0-0 4-0-0 3x4 = 4-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.39 Vert(LL) 0.02 4-7 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.37 Vert(CT) -0.02 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017rrPI2014 Matdx-MP LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=104(LC 10) Max Uplift 3=-80(LC 10), 2=-161(LC 10), 4=7(LC 10) Max Grav 3=90(LC 1), 2=207(LC 1), 4=69(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale=1:11.1 PLATES GRIP MT20 244/190 Weight: 14 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 80 lb uplift at joint 3, 161 lb uplift at joint 2 and 7 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual buss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabdcation, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Ply M11323 T19884606' M11323 J6 MONO TRUSS �Qty 8 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:36 2020 Page 1 • ID:tP6jt7J7xSx_c_fXi4uz9yuFUG-gvml2TGNtoQXUTexf?ew5DjR?7MUV7DFYmip8UzUUjn 1-0-0 6-M 1-0-0 6-0-0 Scale = 1:14.6 3x4 = 6-0-0 6-M LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deb L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.36 Vert(LL) 0.11 4-7 >629 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.83 Vert(CT) -0.12 4-7 >617 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 20 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purling. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=142(LC 10) Max Uplift 3=-131(LC 10). 2=-194(LC 10), 4=8(1_C 10) Max Grav 3=145(LC 1), 2=279(LC 1), 4=102(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131 lb uplift at joint 3, 194 lb uplift at joint 2 and 8 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED U17EK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MTek• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracingof trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 T19884607 M11323 JB MONO TRUSS 20 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 1-0-0 3x5 = 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:37 2020 Page 1 I D:1P6jtzJ7xSx_c_fXi4uz9yuFUGJ5K7FpH7d5YO6dD8Oi99eRGYgXquEaTPmQmNgxzUUjm 8-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.62 Vert(LL) 0.26 4-7 >367 360 TCDL 7.0 Lumber DOL 1.25 BC 0.38 Vert(CT) -0.30 4-7 >319 240 BCLL 0.0 Rep Stress Incr YES We 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017frP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 31 REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=180(LC 10) Max Uplift 3=-175(LC 10), 2=-228(LC 10), 4=15(1_C 10) Max Grav 3=188(LC 1), 2=352(LC 1), 4=145(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale=1:17.4 PLATES GRIP MT20 244/190 Weight: 26 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 3-1-13, Exterjor(2) 3-1-13 to 7-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 175 lb uplift at joint 3, 228 lb uplift at joint 2 and 15 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 WARNING • Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall �• building design. Bracing Indicated is to prevent buckling of individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabdcalion, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type City Ply 4 - �MI`1323 T19884608 M11323 KJ8 MONO TRUSS 4 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:38 2020 Page 1 ID:Log54J?LuEancmZr4Qb7 W MyuFUF-nHuVT9ldOPg FknoKyPgOAeooawBGzwZY?4 WwCNzU Ujl -1`1 7-3-4 11-3-0 1-5 0 7-3-4 3-11-12 Scale=1:20.3 3x4 = 5 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.29 Vert(LL) 0.07 7-10 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.30 Vert(CT) -0.12 7-10 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.46 Horz(CT) 0.02 6 n/a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix -MS Weight: 44 lb FT = 0% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (size) 4=Mechanical, 2=0-11-5, 6=Mechanical Max Horz 2=244(LC 8) Max Uplift 4=-205(LC 8), 2=-305(LC 8), 6=-286(LC 8) Max Grav 4=245(LC 13), 2=466(LC 1), 6=590(LC 13) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=1151/523 BOT CHORD 2-7=-687/1126, 6-7=-68711126 WEBS 3-7=0/330, 3-6=-1236/755 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOT CHORD Rigid ceiling directly applied or 8-9-6 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 205 lb uplift at joint 4, 305 lb uplift at joint 2 and 286 lb uplift at joint 6. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard This item has been 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1-25 electronically signed and Uniform Loads (plf) sealed by Velez, Joaquin, PE Vert: 1-2=-54 Trapezoidal Loads (plf) using a Digital Signature. Vert: 2=0(F=27, B=27)-to-4=-152(F=-49, B=-49), 8=0(F=10, B=10)-to-5=-56(F=-18, B=-18) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall Ar building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing IV1iTek• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPH Quality Criferla, DSE-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Symbols PLATE LOCATION AND ORIENTATION 14-1 3/4' Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. OA,e. - -I- For 4 x 2 orientation, locate plates 0- yis" from outside edge of truss. This symbol indicates the required direction of slots in connector plates. Plate location details available in MiTek 20120 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. r LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSIITP11: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) A General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1 2 3 1. Additional stability bracing for truss system, e.g. TOP CHORDS diagonal or X-bracing, is always required. See SCSI. c1-2 c2-3 2. Truss bracing must be designed by an engineer. For 4 wide truss spacing, individual lateral braces themselves - O WEBS S may require bracing, or alternative Tor I �'•� p bracing should be considered. O 2 U 3 ��a 3 cY O 3. Never exceed the design loading shown and never 4 � U stack materials on inadequately braced trusses. d Oc7-e O 4. Provide copies of this truss design to the building cs r c5-6 1 I— designer, erection supervisor, property owner and BOTTOM CHORDS all other interested parties. 8 7 6 5 5. Cut members to bear tightly against each other. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. © 2012 MiTek® All Rights Reserved !All MiTek® MiTek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or pur ins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.