HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY' EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: WYNNE THE ROYALE IMPACT,
BuilderName: WYNNE
Street: WYNNE DEV.
Permit Office: ST. LUCIE COUNTY
City, State, Zip: PIER E , FL
PermitNumber.
Owner: 4 1
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2) .
1. New construction or existing New (From Plans)
9. Wall. Types (1688.7 sgft.)
Insulation Area
2. Single familyor multiple family Single-family
a. Concrete Block- InYlnsul, Exterior
R=4.1 1448.70 ft2 .
b. Frame - Wood, Adjacent
R=11.0 .240.00 ft2
3. Numberof units, if multiple family 1
c. N/A
R= ft2
4. Numberof Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? Yes
10, Ceiling Types (1750.0 'sgft.)
Insulation Area
a. UnderAttic(Vented)
R=30.0. 1720.00 ft2
6. Conditioned floor area above grade (ft2) 1720
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floorareabelowgrade(ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(155.4 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 155
a. U-Factor: SgI, U=1.04 115.42 ft2
SHGC: SHGC=0.29
b. U=Factor: SgI, U=1.11 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC; SHGC=0.27
a. Central Unit
34.8 SEERA &00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a..Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.3.16 ft.
Area Weighted Average SHGC: 0.285
14. Hot water systems
8. Floor Types (1720.0 sgft.) Insulation Area
a. Electric
Cap:50 gallonsEF:0.970
a. Slab -On -Grade Edge Insulation R=0.0 1720.00ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.090 Total Proposed Modified Loads: 56.10
PASS
Total Baseline Loads: 56.25
I hereby certify that the plans and specifications covered by
Review of the plans and
3,
this calculation are in compliance with the Florida Energy
specifications covered. by this
Code.
calculation indicates compliance
the Florida Energy Code.
with
PREPARED BY:
Before construction is completed
DATE: 4-20-202
this building Will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
OWNER/�f�l
BUILDING OFFICIAL:
DATE:
DATE:
��
- Compliance requires certification by the.air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier'and Insulation Inspection Checklist in accordance with R402.4.1A and this project requires
an envelope leakage test report with envelope leakage no greater than 7.0.0 ACH50 (R402.4.1.2).
REVIEWED FOR
C- C®PLId41VCEFILE PYcODE IVI
CIE COUNTY
4/20/2020 M5 PM EnergyGauge® USA 6.0.02 (Rev: 1) - FlaRes2017 FBA E°di�n ((22017) dCaliCt Software Page 1 of 5
•FORM 9405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE ROYALE IMPA Bedrooms: 3
Address Type:
StreetAddress
Building Type: User
Conditionedkea: 1720
Lot#
Owner Name:
Total Stories: 1
Block/Subdivision:
#of Units: 1
Worst Case: Yes
PlatBook:
BuilderName: WYNNE
RotateAngle:. 90
Street:
WYNNE DEV.
Permit Office: ST. LUCIE COUNTY
CrossVentilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
FamilyType: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design DailyTemp
V Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 EntireHouse
1720 13760
SPACES'
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID' Finished Cooled
Heated
1 BEDROOM
343 2744 No 0
1
1 Yes
Yes
Yes
2 WIC
63 504 No 0
1 No
Yes
Yes
3 M.BATH
56 448 No 0
1 Yes
Yes
Yes
4 KITCHEN
172 1376 Yes 0
1 No
Yes
Yes
5 BATH -45
360 No 0
1 Yes
Yes
Yes
6 BEDROOM 2
204 1632 No 0
1
1 Yes
Yes
Yes
7 ENTRY
98 784 No 0
1 Yes
Yes
Yes
8 LAUNDRY
42 336. No 0
1 Yes
Yes
Yes
9 GREAT/DINING
528 4224 No 0
1 Yes
Yes
Yes
10 BEDROOM 3
169 1352 No 1
1
1 Yes
Yes
Yes
FLOORS
# FloorType
Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation
BEDROOM 52 ft 0.
343 ftz
____
0 1
0
2Slab-On-Grade Edge Insulation
WIC 1 ft 0
63ft2
____
0 1
0
3Slab-On-Grade Edge Insulation
M. BATH 8ft 0
56ft2
___-
0 1
0
4Slab-On-Grade Edge Insulation
KITCHEN 1 ft 0
172ft2
____
0 1
0
5Slab-On-Grade Edge Insulation
BATH 5k 0
45ft2
____
0 1
0
6 Slab -On -Grade Edge Insulation
BEDROOM 2 42.6 ft 0
204 ft2
----
0 1
0
7Slab-On-Grade Edge insulation
ENTRY 6.3ft 0
98ft2
__--
0 1
0
4/20/2020 2:55 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
FloorType Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile
Wood
Carpet
8 Slab -On -Grade Edge Insulation LAUNDRY 6 ft 0
42 ft2
__--
0
1
0
9Slab-On-Grade Edge Insulation GREAT/DINING 48ft 0
528ft2
____
0
1
0
10SIab-On-Grade Edge Insulation BEDROOM 3 13 ft 0
169 ftz
_-__
0
1
0
ROOF
/
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck Pitch
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul. (deg)
1
Gable orShed Metal 1813 ft2
286 ftz
Light
N
0.6
No 0.7
No 0
18.4
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1720 ft2
N
N
CEILING
#
CeilingType Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1.
UnderAttic(Vented) BEDROOM
30
Blown
343ft2
0.1
Wood
2
*Under Attic (Vented) WIC
30
Blown
63ft2
0.1
Wood
3
Under Attic (Vented) M. BATH
30
Blown
56ft2
0.1
Wood
4
UnderAttic(Vented) KITCHEN
30
Blown
172ft2
0.1
Wood
5
UnderAttic(Vented) BATH
30
Blown
45ft2
0.1
Wood
6
UnderAttic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7
Under Attic (Vented) ENTRY
30
Blown
98ft2
0.1
Wood
8
UnderAttic(Vented) LAUNDRY
30
Blown
42ft2
0.1
Wood
9
Under Attic (Vented) GREAT/DINING
30
Blown
528ft2
0.1
Wood
10
Under Attic (Vented) BEDROOM
30
Blown
169f1:2
0.1
Wood
11
Knee Wall (Vented) GREAT/DINING
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent Cavity Width
Height
Sheathing .Framing
Below
Space
n Ft
In
Area
RAW -le Fraction
.Solar
Ahqnr
o
1
N=>E
Exterior Concrete Block - Int Insul BEDROOM
4.1 9
0 8
0
72.0 ft2
0
0
0.4
0
2
S=>W
Exterior Concrete Block - Int Insul BEDROOM
4.1 29
0 8
0
232.0 ft2
0
0
0.4
0
3
W=>N
Exterior Concrete Block- Int Insul BEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
4
S=>W
Exterior Concrete Block - Int Insul M. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
5
N=>E.
Exterior Concrete Block - Int Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.4
0
_ 6
N=>E
Exterior Concrete Block - Int InsuBEDROOM 2
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
7
NE=>SE
Exterior Concrete Block - Int InsuBEDROOM 2
4.1 2
10 8
0
22.7 ft2
0
0
0.4
0
_ 8
E=>S
Exterior Concrete Block - Int InsuBEDROOM 2
4.1 9
0 8
0
72.0 ft2
0
0
0.4
0
_ 9
SE=>SW Exterior Concrete Block- Int InsuSEDR00M 2
4.1 2
10 8
0
22.7 ft2
0
0
0.4
0
10
S=>W
Exterior Concrete Block - Int InsuBEDROOM 2
4.1 14
0 8
0
112.0 ft2
0
0.
0.4
0
11
NE=>SE
Exterior Concrete Block- Int Insul ENTRY
4.1 1
5 8
0
11.3 ft2
0
0
0.4
0
4/20/2020 2:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
'FORM R405-2017 INPUT SUMMARY CHECKLIST REPnRT
WALLS.
Adjacent Space. Cavity Width
_
Height
Sheathing Framing Solar Below
0
12
E=>S Exterior Concrete Block- Int Insul ENTRY 4.1 5 0 8
0 40.0 ft2
0
0 0.4
0
13
S=>W Exterior Concrete Block-.Int Insul LAUNDRY 4.1 6 0 8
0 48.0 ft2
0
0 0.4
0
14
N=>E Exterior Concrete Block- Int InsuIGREAT/DINT 4.1 28 0 8
0 224.0 ft2
0
0 0.4
0
15
W=>N Exterior Concrete Block- Int InsuIGREAT/DINI 4.1 20 0 8
0 160.0 ft2
0
0 0.4
0
_ 16
N=>E Exterior Concrete Block - Int InsuBEDR00M 3 4.1 13 0 . 8
0 104.0 ft2
0
0 0.4
0
17
N=>E Garage Frame - Wood BEDROOM 3 11 30 8
240.0 ft2
0.23 0.4
0
DOORS
# Ornt DoorType Space Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 E=>S Insulated ENTRY None
.32 3
6 8
20 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
Overhang
V
# Ornt ID Frame Panes NFRC U-Factor SHGC Imp
Area Depth
Separation IntShade
Screening
1 W=>N 3 Metal Low-ESingle Yes 1.04 0.29 N
32.4 ft2 1 ft 0 in
1 ft 5 in
Drapes/blinds
Exterior5
2 S=>W 4 Metal Low-ESingle Yes 1.04 0.29 N
6.9 ft2 1 ft 0 in
1 ft 5 in
None
None
3 E=>S 8 Metal Low:ESingle Yes 1.04 0.29 N
23.2 ft2 1 ft 0 in
1 ft 5 in
None
None
4 N=>E 14 Metal Low-ESingle Yes 1.04 0.29 N
36.8 ft2 1 ft 0 in
1 ft5 in
None
None
5 W=>N 15 Metal Low-ESingle Yes 1.11 0.27 N
40.0 ft2 10 ft 0 in
1 ft 5 in
None
None
6 N=>E 16 Metal Low-ESingle Yes 1.04 0.29 N
16.2 ft2 1 ft 0 in
1 ft 5 in
None
None
GARAGE
# FloorArea CeilingArea Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 300 f12 300 ft2 30 ft
8 ft
11
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse ProposedACH(50) .000356 1605.3 88.13 165.74 .1233
7
HEATING SYSTEM
# SystemType Subtype Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split Single HSPF:8.5
34.8kBtu/hr
1
sys#1
COOLING, SYSTEM
# System Type Subtype Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1 Central Unit/ Split Single SEER: 15 34.8 kBtu/hr cfm
0.85 1
sys#1
4/20/2020 2:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software . Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.97
50 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # CompanyName
System Model# CollectorModel#
Area Volume
FEF
None None
ft2
DUCTS
/ ---Supply--
-- Return —
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area
LeakageType
Handler
TOT
OUT QN
RLF
Heat Cool
1 Attic
6 155 ft2
Attic
55 ft2
DefaultLeakage
Attic
(Default) c(Default) c
1 1
TEMPERATURES
ProgramableThermostat: Y
Ceiling Fans:
CoolingJan Feb
HeatinJan H Feb
Mar .
HX Mar
Apr
f Apr f
May.
i May
Jun Jul
ri Jun Jul
Auge
Au4
Sep
Oct
f Oct hNov
Nov.
Dec
Dec
H
Ventin Jan [[ ]] Feb
Mar
[X] Apr [
May
Jun Jul
Aug
[ Se
[X] Oct
Nov
Dec
ThermostatSchedule: HERS 2006 Reference
Hours
ScheduleType
1
2 3
4
5 6
7
8
9 10
11
12
Cooling(WD) AM
78
78 78
78
78 78
78
78
80 80
80
80
PM
80
80 78
78
78 78
78
78
78 78
78
78
Cooling(WEH) AM
78
78 78
78
78 78
78
78
78 78
78
78
PM
78
78 78
78
78 78
78
78
78 78
78
78
Heating(WD) AM
66
66 66
66
66 68
68
68
68 68
68
68
PM
68
68 68
68
68 68
68
68
68 68
66
66
Heating(WEH) AM
66
66 66
66
66 68
68
68
68 68
68
68
PM
68
68 68
68
68 68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8lbs/sq.ft.
0 ft2
Oft
0.3
BEDROOM
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
Default(8lbs/sq.ft. '
ft2
ft
0.3
M. BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
KITCHEN .
Default(8lbs/sq.ft.
ft2
ft
0.3
BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
BE 2
Default(S lbs/sq.ft.
ft2
ft
0.3
ENTRY
Default(81bs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(81bs/sq.ft.
ft2
ft
0.3
GREAT/DINING
Default 8lbs/s .ft.
ft2
ft
0.3
BEDROOM-3 .
4/20/2020 2:55 PM EnergyGaugeO USA 6.0.02 (Rev. 1.) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE ROYALE IMPACT Builder Name: WYNNE
Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
!L
Design Location: FL, Fort Pierce
0
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the bullding:envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
-not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in dropped ceiling/soffit
any PP 9 /soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope:insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows; skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Pytgnrl behind 126pong anti wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire 0 nk! cover nlates and walls or ceilinag
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
4/20/2020 2:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* =100
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b). Return .ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEERICOP
6. Conditioned floor area (sq. ft.)
6.
1720
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-facton(weighted average)
7a.
1.058
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.285
14. Heating system: Capacity
34.8
c) Area
7c.
155.4
a) Split system heat pump . HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1061.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
19.0
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating.credit
0 Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will'be installed (or exceeded) in- this home before final inspection. Otherwise,.a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date: l�
Address of New Home: WYNNE DEV. k City/FL Zip: FT. PIERCE. FL
4/20/2020 2:55:34 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1