HomeMy WebLinkAboutPolyglass TU P6/18/2020 Florida Building Code Online
BCIS Home Lag In User Regislratwn Hot TOPLts Submit Surcharge Slats 6 Facts Pubbcanons Contact Us BCIS Site Map Lmks Search
`; Product Approval
dbpr USER: Public User
proval Mnnu s Pmducr a, .t,phciu, n 5,ai,ch > anpLuv,pn On > Appllotibb Detail
FL # FL5259-R29
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer POLYGLASS USA
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233.1330 Ext 242
malpert@polyglass.com
Authorized Signature Maury Alpert
malpert@polyglass.com
Technical Representative TECH REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(866) 802-8017
uspolyglasstechniwl@polyglass.com
Quality Assurance Representative QA REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(888) 410-1375
uspolyglasstechniol@polyglass.com
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
10/21/2022
Validated By
John W. Knezevich, PE
Validation Checklist • Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL5259 R29 COI 2019 01 C01 NIEMINEN.=
kZT.r
ASTM D1970 2015
ASTM D226 2009
ASTM D4798 2011
ASTM D6163 2008
ASTM D6164 2011
ASTM D6222 2011
ASTM 06509 2009
https:/Aw.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQvitDgvbSgAaZp3Crk2vS%2fegOlipmaCfgJXCANGg3CNQhK3OSg%3dp/3d 112
6/18/2020 Florida Building Code Online
FM 4474 2011
FRSA/TRI April 2012 2012
UL 1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/15/2019
Date Validated 10/16/2019
Date Pending FBC Approval 10/20/2019
Date Approved 12/10/2019
Summary of Products
FL # Model, Number or Name Description
5259.1 Polyglass Roof Roofing underlayments
Underlayments
Limits of Use
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-622.5
Other: 1.) The design pressure in this
application relates to one particular
underlayment system (over concrete deck) for
use under foam -on tile systems (where the
underlayment forms part of the load -path).
Refer to ER Section 5.6.1 for other systems,
other deck types and associated maximum
design pressures. 2.) Refer to ER Section 5 for
other limits of use.
Installation Instructions
FL5259 R29 11 2019 10 FINAL ER POLYGLASS UNDERLAYMENTS F 5 59-
R29.p4
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL5259 R29 AE 2019 10 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
R29u12
Created by Independent Third Party: Yes
Contact tact Us :: 2601 Blair Stone Reei, Tallahassee FL 32399 Phone, 850-487-1824
The State of Florida is an AA/EEO employer 4pp-,d1ht 2007-2 13 51tl :: Pdyapv Slabmant :: Attest bI1M Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your a -mad address released in response to a public-reCords mi,mst, do not send elecumnlc
mail to tms entity. Instead, contact the oMo. by phone a- by traditional mail. If you have any questions, please contact 850.487.1395. -pursuant td session 455.275(1),
Fk nda statute,, effective October 1, 2012, Ikensees licensed under Chapter 455, F.S. must provide the Department with an email address If may have one. The meals
provided may be used for official communication with the licensee. However email addresses arc public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under chapter 455, F.S., please click b=.
product Approval ACCepts:
Im El W�i_zl eeroa
Credit Card
Safe
https:ll v .floridabuilding.org/pr/pr. app_tlo.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS°/21egOlipmaCfgJXCANGg3CNQhK3OSg%3da/o3d 2l2
NEMO I etc.
certificate of Authorizotion p324SS
353 Christian Street, Unit N13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
-'1?ILtI_1/1� iCola-!--
Polyglass USA, Inc. Evaluation Report P12060.02.09-R25
1111 West Newport Center Drive
Deerfield Beach, FL 33442
(954)233-1230
FL5259-R29
Date of Issuance:02/24/2009
Revision 25: 20/14/2019
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 6" Edition (2017) Florida Building Code sections noted herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMOIetc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO(etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 16
Prepared by:
': • ,,
Robert J.M. Nieminen, P.E.
%'FF•5:;;:a '.`
. srdxa� �,,,.
Florida Registration NO. $9166, Florida OCA ANE3983
'""'"•u"" The facsimile seal authorized Robert Nieminen. P.E.on
does not an
10/34/2019. This does not serve as an electronically signed document. .
CERTIFICATION OF INDEPENDENCE:
1. NEMOletc. does not have, nor does It intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMOI etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither NEMOIetc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019 NEMO ETC, LLC
*NEMO I etc.
1. SCOPE:
Product Category:
Roofing
Sub -Category:
Underlayment
Compliance Statement:
Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated
compliance with the
following sections of the
Wit Edition (2017) Florida Building Code through testing in accordance with the
following Standards.
Compliance is subject to
the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Uplift
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897
2012
1507.2.3 / 1507.1.1
Physical Properties
ASTM D226
2009
1507.2.4 11507.1.1, 1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012
2012
1507.11.2
Physical Properties
ASTM 06163
2008
1507.11.2
Physical Properties
ASTM D6164
2011
1507.11.2
Physical Properties
ASTM D6222
2011
1507.11.2
Physical Properties
ASTM D6509
2009
TA5 110
Accelerated Weathering
ASTM D4798
2011
3. REFERENCES:
Entity
Examination
Reference
Date
Entity
Examination
Reference
Date
ERD (TST 6049)
Wind Uplift
11757.08.01-1
08/13/2001
ERD (TST 6049)
Tensile adhesion
P40390.04.15
D4/03/2015
ERD (TST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD (TST 6049)
TA5103
P44360.10.14-R7
05/18/2015
ERD (TST 60491
Wind Uplift
P1740.01.07
01/04/2007
ERD ITST 6049)
Wind Uplift
PLYG-SC8905.05.16-1
05/17/2016
ERD (TST 6049)
ASTM 01970
P5110.04.07-1
04/11/2007
ERD ITST 6049)
ASTM D1970
PLYG.SC10130.06.16.1
06/27/2016
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/22/2008
ERD (TST 6049)
Tensile adhesion
PLYG.SC10130.06.16.2
06/27/2016
ERD (TST 6049)
Wind Uplift
P30540.11.09-R1
11/30/2009
ERD (TST 6049)
TAS103
PLYG-SC30130.06.16.3
06/27/2016
ERD (TST 6049)
Tensile Adhesion
P11030.11.09.1
11/30/2009
ERD (TST 6049)
ASTM D1970/D4798
PLY13-SC8080.07.16
07/16/2016
ERD (TST 6049)
Wind Uplift
P11030.11.09.2
11/30/2009
ERD ITST 60491
Wind Uplift
PLYG.SC71025.10.16
10/12/2016
ERD (TST 6049)
ASTM D4977
P11030.11.093
11/30/2009
ERD ITST 6049)
TAS103
PLYG-SC13040.12.16
12/27/2016
ERO ITST 6049)
ASTM D1970
P33360.06.10
06/25/2010
ERD ITST 6049)
30/90 physicals
PLYG-SC11900.03.17
03/10/2017
ERD (TST 6049)
TA5103
P33370.03.11
03/02/2011
ERD (TST 6049)
TA5103
PLYG-SC12115.08.17
08/08/2017
ERD (TST 60491
Tensile Adhesion
P33370D4.11
04/26/2011
ERD(T5T 6049)
TAS103
PLYG.SC13035.08.17
10/31/2017
ERD (TST 6049)
ASTM D1970
P37300.10.11
10/19/2011
FM (TST 1867)
Wind Uplift
3004091
01/12/2000
ERD (TST 6049)
TAS103
P40390.08.12.1
08/06/2012
ICC-ES(EVL 23961
IBC Compliance
ESR-1697
04/O112019
ERD(TST 60491
Tensile Adhesion
P40390.08.12.2
08/07/2012
M-D ICER 1592)
HVHZ Compliance
NOA 17-0614.22
07/06/2017
E RD(TST 60491
Tensile Adhesion
C41420.09.12.3
09/11/2012
MTI(TSr 2508)
ASTM 04798
)X2OH7A
04/01/2008
ERD (TST 60491
Wind Uplih
P39680.03.13
03/04/2013
NEMO(TST6049)
ASTM 01970
4-PLYG.18.004.03.18
03/29/2018
ERD (TST 6049)
ASTM D2970
P45370.G4.13
04/26/2013
NEMO (TST 6049)
Wind Uplift
4L-PLYG-18-003.01.19
01/11/2019
ERD (TST 6049)
Wind Uplift
P3738.02.07-R2
D4/29/2013
NEMO (TST 6049)
ASTM D6163
45-PLYG48.002.01.19-A
01/24/2019
ERO(TST 6049)
Wind Uplift
11757.04.01.1-R1
04/30/2013
NEMO (TST 60491
ASTM D6222
4S-PLYG.18-002oS.19-c
05/20/2019
E RD(TST 6049)
ASTM 06164
P37590.03.13.3A
05/06/2013
NEMO (TST 60491
TA5103
4S-PLYG-18-004.10.19-G
10/08/2019
ERD (TST 6G49)
ASTM D6S09
P37590.03.13.1-R1
06/26/2013
NEMO (TST 6049)
TA5103
45-PLYG-18.004.10.19.1
10/08/2019
ERD (TST 6049)
Wind Uplift
P41630.08.13
08/06/2013
NEM017ST 60491
TAS103
45-PLYG-18.004.10.19-L
10/09/2019
ERD (TST 6049)
ASTM D4601
P45940.09.13
09/04/2013
NEMO (TST 60491
TAS 103
4i-PLYG.19-SSUDL-01.A
10110/2019
ERO(TST 60491
Wind Uplift
P31751.05.03-R1
11/26/2013
PRI (TST 5878)
Tensile Adhesion
PRIG1111
04fO8/2002
ERD ITST 6G49)
Wind Uplift
P11781.11.03-R1
11/26/2013
PRI (TST 5878)
TAS 103
PUSA-018.02-01
07/14/2003
ERD (TST 6049)
30/90 physicals
P45270.05.14
05/12/2014
PRI (TST 5878)
TAS 103
PUSA-035-02.01
09/'29/2006
ERD (TST 6049)
Tensile adhesion
6020.09.14-5
09/08/2014
Pro (TST 5878)
TAS 103
PUSA-055-02.02
12/10/2007
ERD ITST 6049)
Tensile adhesion
6020.09.14-6
09/09/2014
PRI (TST 5878)
ASTM D6222
PUSA-061-02-02
01/28/2008
ERD (TST 60491
Tensile adhesion
P46S20.10.14
10/03/2014
PRI (TST 5878)
ASTM 06164
PUSA-088.02-01
07/29/2009
ERO(TST 60491
ASTM 01970/D4798
P43290.10.14
10/17/2014
Polyglass USA
P/L Affidavit
Mule -Hide Cmss Ltg
03/01/20DB
NEMO ETC, U.C.
Evaluation Report P12060.02.09-R25
Cenifteate a/Authariration 432455
G" EDITION(2017) FBC
NON-HVHZ EVALUATION
FL52S9.RZ9
Polyglass Roof Underlayments;
(954) 233-1230
Revision
25: 10/14/2019
Page 2 of 16
Entity Examination
ERD(TST60491 TA5103
C
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.15
4.16
4.17
Reference Date I 121LIJ
PLYG-SC7SS0.03.15 03/24/2015 Polyglass USA
UL(QUA9625)
ONEMOletc.
Examination Reference Date
Materials Affidavit Polystick Compound 08/18/2011
Quality Control Service Confirmation 09/13/2018
PRODUCT DESCRIPTION:
Product
Specification
Plant(s)
Description
Elastobase
ASTM D6163
FL
Fiberglass -reinforced, SBS modified bitumen base sheet
Elastobase P
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen base sheet
Elastoflex G TU
M-D 13-004
PA
Polyester -reinforced, modified bitumen tile underlayment
FRSA/TRI April 2012
composed of a sand -surfaced SBS modified bitumen back-
side and granule -surfaced APP modified bitumen top -side
Elastoflex S6 G
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRI April 2012
Elastoflex 56 G FR
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRI April 2012
Mule -Hide SA-APP Cap Sheet
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRI April 2012
HydraGuard Dual Pro
ASTM D1970
FL
Nominal 60-mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface
HydraGuard Tile Pro
ASTM D1970
FL
Nominal 60-mil thick dual -layer rubberized asphalt
TAS 103
waterproofing membrane, fiberglass reinforced, with a
FRSA/TRI April 2012
polyester fabric surface
Mule -Hide SA-APP Cap Sheet
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
(FR)
FRSA/TRI April 2012
Polyflex G
ASTM 06222
FL
Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRI April 2012
use as an alternate to Heat Applied "Cap Sheet" in the
"Two Ply System" from FRSA/TRI April 2012 (04-12)
beneath mechanically fastened or adhered tile roof
systems
Polyflex G FR
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRI April 2012
use as an alternate to Heat Applied "Cap Sheet" in the
"Two Ply System" from FRSA/TRI April 2012 (04-12)
beneath mechanically fastened tile roof systems
Polyflex SA P
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRI April 2012
Polyflex SA P FR
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRI April 2012
Polyglass Base
ASTM D6509
FL
Fiberglass -reinforced, APP modified bitumen base sheet
Polyglass G2 Base Sheet
ASTM D4601
AL
Fiberglass -reinforced, asphaltic base sheet
Polystick IR-Xe
ASTM D1970
FL, PA
Nominal 60-mil thick rubberized asphalt waterproofing
membrane, glass fiber reinforced, with an aggregate
surface
Polystick MTS Plus
TA5 103
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI April 2012
membrane, glass fiber reinforced, surfaced with
polyclefinic film surface
NEMO ETC, U.C. Evaluation Report P12060.02.09-R25
Certificate ofAuthadwrion 932455 6'"EDITION 12017) FBC NON HVH2 EVALUATION FL5259-R29
Polyglass Roof Underlayments; (954) 233.1230 Revision 25: 10/14/2019
Page 3 of 16
ONEMOJeft.
4. PRODUCT DESCRIPTION:
Product
Specification
Plant(s)
Description
4.18
Polystick MU-X
ASTM D1970
FL, NV, PA
Nominal S4-mil thick dual -layer rubberized asphalt
(See Section 5.8)
waterproofing membrane, fiberglass reinforced, with a
polypropylene film surface
4.19
Polystick TU Max
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
TAS 103
membrane with a 190 g/m2 polyester fabric surface
FRSA/TRI April 2012
1
4.20
Polystick TU P
TAS 103
TX
Nominal 130-mil thick rubberized asphalt waterproofing
FRSA/TRI April 2012
membrane, glass-fiber/polyester reinforced, with a
granularsurface
4.21
Polystick TU Plus
ASTM D1970
FL, PA
Nominal 80-mil thick rubberized asphalt waterproofing
TAS 103
membrane, glass fiber reinforced, with a polyester fabric
FRSA/TRI April 2012
surface
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO]etc. nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless
retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Wood Shakes
Underlayment
Asphalt Shingles
Nail -On Tile
Foam -On Tile
Metal
&Shingles
Slate
Elastobase
Yes
Yes
Yes
Yes
Yes
Yes
(Base Sheet in 2-Ply system)
(Base Sheet in 2-ply system)
Elastobase P
Yes
Yes
Yes
Yes
Yes
Yes
IBase Sheet in 2-pjymtem)
(Base Sheet in 2-ply system)
Polyglass Base
No
Yes
Yes
No
No
No
IB se Sheet In 2-ply system)
(Base Sheetin 2g1ysynem)
Polyglass G2 Base
No
Yes
Yes
No
No
No
lease Sheet in 2-ply system)
(Base Sheet in 2-ply system)
Elastoflex G TU
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Elastoflex 56 G
Yes
Yes
Yes (See 5.5.11
No
Yes
Yes
Elastonex 56 G FR
Yes
Yes
No
No
Yes
Yes
HydraGuard Dual Pro
Yes
No
No
Yes
Yes
Yes
HydraGuard Tile Pro
Yes
Yes
Yes (See 5.5.11
Yes
Yes
Yes
Mule -Hide SA-APP Cap
yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Sheet
Mule -Hide SA-APP Cap
Sheet(FR)
Sheet (FR)
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
PolynexG
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyflex G FR
Yes
Yes
No
No
Yes
Yes
I alyflex SAP
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
I olyflex SA P FR
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polystick IR.Xe
Yes
No
No
No
Yes
Yes
NEMO ETC, I.I.C. Evaluation Report P32060.02.09-1125
Certl(xoteoJAuthorianfion a32455 6n' EDITION 12017) FBC NON-HVHZ EVALUATION FL52S9-R29
Polyglass Roof Underlayments; (9S4) 233-1230 Revision 25: 10/14/2019
Page 4 of 16
ONEMOletc.
TABLE 1: ROOF COVER OPTIONS
Underlayment
Asphalt Shingles
Nail -On Tile
Foam -On Tile
Metal
Wood Shakes
&Shingles
Slate
Polystick MTS Plus
Yes
Yes
No
Yes
Yes
Yes
Polystick MU.X
Yes
No
No
Yes
Yes
Yes
Polystick TU Max
I No
Yes
Yes (See 5.5.1)
Yes
No
No
Polystick TU P
No
Ves
Yes (See 5.5.1)
No
No
No
Polystick TU Plus
7 Yes
Yes
Yes (See 5.5. 11
Yes
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
TABLE IA: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS'
Florida Product
Adhesive
Approval
Underlayments
DAP Foam Touch'n Seal StormSond
FL14506
Polystick TU Max or Polystick TU Plus
Roof Tile Adhesive
HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or
Dow TileBond'"
FL22525
Polystick TU Plus
Elastoflex G TU, Elastoflex S6 G, HydraGuard Tile Pro, Mule -Hide SA-APP
ICP Adhesives Polyset' AH-160
FL6332
Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex G, Polyflex SA P,
Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus
Elastoflex S6 G, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule-
ICP Adhesives Polyset° RTA-1
FL6276
Hide SA-APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P FR,
Polystick TU Max, Polystick TU P or Polystick TU Plus
5.6 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Substrates (designed to meet wind loads for project)
Underlayment
Application
Type Primer Material(s)
Deck /
(Optional) ASTM D41
plywood, OSB, Southern Yellow Pine or Huber
HydraGuard Dual Pro,
Engineered Woods "ZIP System' Panels
HydraGuard Tile Pro,
sheathing
ASTM D41
structural concrete
Polystick (all variations),
self-
ASTM C1289 Type II Class 1 polyisocyanurate, ASTM
Mule -Hide SA-APP Cap
adhering
Insulation
(Optional) ASTM D41
C1289 Type V polyisocyanurate-composite, DensDeck
Sheet, Mule -Hide SA-APP
or WB-3000
Cap Sheet (FR), Polyflex
Prime or SECUROCK Gypsum -Fiber Roof Board
Base
N/A
ASTM D226 felt, Elastobase, Elastobase P or Mule -Hide
SA P or Polyflex SA P FR
Sheet
Nail Base
Deck
ASTM D41
structural concrete
Insulation
(Optional) ASTM D41
DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board
Elastoflex G TU, Elastoflex
S6 G or Elastoflex S6 G FR
hot asphalt
Base
ASTM D226 felt, Elastobase, Elastobase P, Mule -Hide Nail
Sheet
N/A
Base or Polyglass G2 Base
Deck
ASTM D41
structural concrete
Insulation
(Optional) ASTM D41
DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board
torch-
Polyflex G or Polyflex G FR
applied
Base
Elastobase, Elastobase P, Mule -Hide Nail Base, Polyglass
N/A
Sheet
G2 Base or Polyglass Base
' Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R25
Certificate OfAwhximwn Y32455 6"'EDITION (2017)FBC NON-HVHZ EVALUATION FL5259-RZ9
Polyglass Roof Underlayments; (954) 233.1230 Revision 25: 10/14/2019
Page 5 of 16
NNEMO I etc.
5.6.1 Wind Resistance for Underlayment Systems in Foam -On Tile Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptively addressed in FRSA/TRI April
2012 (04-12) and are used in foam -on or mortar -set tile applications. Maximum Design Pressure is the result of testing for
wind load resistance based on allowable wind loads and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin
of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609
for determination of design wind loads.
#1 Maximum Design Pressure =-52,5 osf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, 058 sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Joints: Min. 4-Inch wide strips of Elastoflex SA-V over all OSB joints
Base Ply: Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#2 Maximum Design Pressure=-90 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P Fit, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#3 Maximum Design Pressure =-97.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 134" ring shank nails
through 32 ga., 1-5/8" diameter tin caps spaced 12-inch D.C.
#4 Maximum Design Pressure = -105 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1Y" ring shank nails
through 32 ga., 1-5/8" diameter tin caps spaced 12-Inch D.C.
#5 Maximum Design Pressure = -135 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 or ASTM D42
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#6 Maximum Design Pressure = -315 Dsf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR,
Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered.
#7 Maximum Design Pressure = -622.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
NEMO ETC, U.C. Evaluation Report P12060.02.09-R25
Certifmte ofAothonratlon a32455 6" EDITION (2017)FBC NON-HVHZ EVALUATION FL5259-R29
Polyglass Roof Underlayments; (954) 233-1230 Revision 25: 10/14/2019
Page 6 of 16
ONEMO etc.
#8 Maximum Design Pressure =-30.0 psf*:
Deck: Min. 15/32-inch 058 to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nall Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch D.C. at the 3-inch wide side laps and 6-inch D.C. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
09 Maximum Design Pressure = -37.5 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-Inch D.C. at the 3-inch wide side laps and 6-inch D.C. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self-adhered-
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#10 Maximum Design Pressure = -37.5 DO*:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) or two (2) layers ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
#11 Maximum Design Pressure=-45 psf*:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) layer ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 2-inch wide side laps and 4-Inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered or Elastoflex G TU, applied in full mopping of hot asphalt.
#12 Maximum Design Pressure = -45 psf*:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two (2) layers ASTM 0226, Type II felt
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underfayment only) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered or Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
#13 Maximum Design Pressure =-45 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#14 Maximum Design Pressure = -45.0 psf:
Deck: APA rated, 7116 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing; 6-inch c.c. at the 3-inch wide side laps and 6-inch D.C. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
NEMO ETC, U.C. Evaluation Report P12060.02.09-R25
Cenifcare cfAuthorkobae 132455 6O1 EDITION(20171 FBC NON-HVHZ EVALUATION FL5259.R29
Polyglass Roof Underlayments; (9541 233-1230 Revision 25: 10/14/2019
Page 7 of 16
NNEMOletc.
915 Maximum Design Pressure =-45.0 osf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing: 6-Inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt.
#16 Maximum Design Pressure = -45.0 osf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#17 Maximum Design Pressure = -52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAX%Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#18 Maximum Design Pressure =-52.5 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#19 Maximum Design Pressure =-52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-Inch o.c. at the 3-Inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#20 Maximum Design Pressure =-60 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch D.C. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied.
#21 Maximum Design Pressure =-60 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-Inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
NEMO ETC, U.C. Evaluation Report P32060.02.09-R25
CerNfirate of Authorization 432455 6" EDITION (20171 FSC NON-HVHZ EVALUATION FL5259-R29
Polyglass Roof Underlayments; (954) Z33-1230 Revision 25: 10/14/2019
Page 8 of 16
ONEMO I etc.
#22 Maximum Design Pressure = -60.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch D.C. at the 3-Inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#23 Maximum Design Pressure = -60.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, 058 sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch D.C. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt.
#24 Maximum Design Pressure = -60.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, 058 sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-Inch D.C. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#25 Maximum Design Pressure=-67.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underlayment)
Fasteners: 12 ga. x 1.25-Inch long x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-Inch o.c. at the 4-Inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#26 Maximum Design Pressure =-67.5 psf
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-inch D.C. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Primer: (Optional) PG 100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#27 Maximum Design Pressure = -67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch D.C. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
NEMO ETC, U.C. Evaluation Report P32060.02.09-R25
O,M(rote ofavthorunn.#32455 6"EDITION 12017)FBC NON-HVHZ EVALUATION FL5259-R29
Po:yglass Roof Underiayments; (954) 233-1230 Revision 25: 10/14/2019
Page 9 of 16
ONEMID etc.
#28 Maximum Design Pressure =-67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#29 Maximum Design Pressure =-75 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underloyment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG U14 HO with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat
Bottom Plates (AccuTrac), Trufast HD with Trufast 3-Inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 10-Inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#30 Maximum Design Pressure =-90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch D.C. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#31 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG 014 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-Inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#32 Maximum Design Pressure=-90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
H33 Maximum Design Pressure=-90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underloyment)
Fasteners: Dekfast 014 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip H14 with OMG Flat
Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c, at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#34 Maximum Design Pressure = -90.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180" into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch D.C. at two (2) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
NEMO ETC, U.C. Evaluation Report P12060.02.09-R25
Ceal/lmte olAutno.irotion#32455 6"'EDITION (2017) FBC NON-HVH2 EVALUATION FL5259-R29
Polyglass Roof Underlayments; (954) 233.1230 Revision 25: 10/14/2019
Page 10 of 16
NNEMOletc.
#35 Maximum Design Pressure =-90.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
P36 Maximum Design Pressure = -90.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate Installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polyflex G. torch -applied.
#37 Maximum Design Pressure = -97.5 its
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#38 Maximum Design Pressure = -97.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (Fill, Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#39 Maximum Design Pressure = -97.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt.
#40 Maximum Design Pressure = -97.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSS sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
941 Maximum Design Pressure = -105 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastonex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
NEMO ETC, I.I.C. Evaluation Report P32060.02.09.R25
Certhrote o7Authonmrion#32a55 6"EOITION(2D171 FBC NON.HVH2 EVALUATION FL5259.R29
Polyglass Roof Underlayments; (9541 233-1230 Revision 25: 10/14/2019
Page 11 of 16
NNEMOletc.
#42 Maximum Design Pressure = -10S.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSS sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#43 Maximum Design Pressure = -105.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, 058 sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoftex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
#44 Maximum Design Pressure = -105.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c, at three (3) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#45 Maximum Design Pressure=-112.5 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer at all tin -caps
Base Ply: Polystick MTS Plus, self -adhered
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#46 Maximum Design Pressure = -120 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#47 Maximum Desien Pressure = -120 psf
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast 1114 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-Inch o.c. at the 4-Inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt.
NEMO ETC, I.I.C. Evaluation Report P32060.02.09-1125
Cerrl/lcme 4JAurhorimrion 932455 6'" EDITION (2017) FEIC NON.HVHZ EVALUATION FL5259-R29
Polyglass Roof Underlayments; (954) 233-1230 Revision 25: 10/14/2019
Page 12 of 16
NNEMO I etc.
#48 Maximum Design Pressure=-127.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, 058 sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-Inch o.c. at the 4-Inch wide side laps and 9-inch D.C. at four (4) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
d49 Maximum Design Pressure =-127.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, 058 sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch o.c. at the 4-Inch wide side laps and 9-inch D.C. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elasto8ex 56 G, applied in full mopping of hot asphalt.
1150 Maximum Design Pressure = -127.5 psf:
Deck: APA rated, 19/32 CAT, D.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
5.6.1.1 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum Design
Pressure of -45 psf.
5.6.1.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that
required under FRSA/TRI April 2012 (04-12), Appendix A, Table IA.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure
determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a
qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI VVDl, FM Loss
Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk' carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment
Maximum Exposure (days)
Elasto8ex G TU, HydraGuard Dual Pro, HydraGuard Tile Pro, Polystick MTS Plus, Polystick TU
Max, Polystick TU P or Polystick TU Plus
180
Polystick IR-Xe or Polystick MU-X
90
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass Base
30
180
Elastoflex S6 G, Elastoflex 56 G FR, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet
(for adhesive -set tile)
UNLIMITED
(FR), Polyflex G, Polyflex G FR, Polyflex SA P or Polyflex SA P FR
(for mechanically fastened roof
prepared roof covers)
5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing
felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth in
Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance.
NEMO ETC, LLC. Evaluation Report P12060.02.09-1125
CertlJkote OfAuthorizatlon M32455 6"EDITION (2017)FeC NON-HVH2 EVALUATION FL5259-1129
Polyglass Roof Underlayments; (954) 233.1230 Revision 25: 10/14/2019
Page 13 of 16
NNEMO I etc.
5.9 Tile Slippage Limitations (FRSA/TRI April 2012 (04-12)):
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These
slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Slope
Elastoflex G TU
Flat
30-tile stack
7:12
Lugged
8-tile stack (6 over 2)
6:12
Elastoflex S6 G or S6 G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
HydraGuard Tile Pro
Flat or Lugged
6-tile stack 14 over 2)
7:12
Polyflex G or G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polyflex SA P or SA P FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polystick MTS Plus
Flat
6-tile stack (4 over 2)
5:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick TU Max
Polystick TU P
Flat
6-tile stack (4 over 2) or 10-Life stack
7:12
Lugged
6-tile stack (4 over 2)
7:12
Lugged
10-tile stack
6:12
Fiat
6-tile stack (4 over 2)
6:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick TU Plus
Flat or Lugged
6-tile stack (4 over 2)
7:12
Flat or Lugged
10-tile stack
6:12
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the
Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application, and prime the substrate (if applicable).
6.3 Elastobase, Elastobase P or Mule -Hide Nail Base:
6.3.1 Non -Tile Aoolications:
Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed and Polyglass published requirements.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FR, Mule -
Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot
asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer
underlayment, as set forth in Table 1.
6.3.2 Tile Applications,
Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two Ply
System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.1 herein, coupled with FRSA/TRI April
2012 (04-12) Installation Manual.
NEMO ETC, U.C. Evaluation Report P12060.02.09-1125
Ceniftove OfAuthorim0on e32455 6"EDITION J20171 FBC NON-HVHZ EVALUATION FLS259-R29
Polyglass Roof Underlayments; (954) 233-1230 Revision 25: 10/14/2019
Page 14 of 16
NNEMO[etc.
6.4 HydraGuard Dual Pro, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P,
Polyflex SA P FR, Polystick IR-Xe, Polystick MTS Plus, Polystick MU-X, Polystick TU Max, Polystick TU P or Polystick TU Plus:
6A.1 General:
All seal -lap seams (selvage laps) must be firmly rolled with a in
accordance with Polyglass requirements to ensure full contact
and adhesion. For HydraGuard Dual Pro and HydraGuard Tile
Pro, align the edge of the top sheet to the end of the glue
pattern (the sheet will overlap the fabric).
View of Ovelap5eam of HydraGuard Dual Pro and HydraGuard Tile Pro
6.4.2 Non -Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D1970 (except Polystick TU P) underlayment in FBC
Table 1507.1.1 for the type of prepared roof covering to be installed and Polyglass published requirements.
6.4.3 Tile Applications (excludes HydraGuard Dual Pro. Polystick lR-Xe and Polystick MU-X):
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI April 2012 (04-12) and
Polyglass published requirements.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet
fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.1 herein.
6.4.4 Multi -Ply Underlavment Systems:
Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick MTS Plus, Polystick MU-X, Polystick TU Max,
Polystick TU P or Polystick TU Plus is allowable for use under mechanically attached prepared roof systems. Limits of use are
those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is
desired.
Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is
allowable for use under adhesive -set tile systems. Limits of use are those associated with the top -layer material. This is not a
requirement, but is allowable if a 2-ply underlayment system is desired.
6.5 1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR:
6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published installation
requirements. For use in the applications:
✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System"
from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems Or the Hot Asphalt applied "Cap Sheet'
in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems.
✓ Elastoflex 56 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System"
from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet'
in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered the roof systems.
✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing' (ASTM D6380, Class M) in the "Single Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap
Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems.
NEMO ETC, LLC. Evaluation Report P12060.02.09-R25
Cenift-re orAwh.d.ation N32455 6"'EDITION (2017) FBC NON.HVHZ EVALUATION F1.5259-1129
Polyglass Roof Underlayments; (954) 233-1230 Revision 25: 10/14/2019
Page 15 of 16
*NEMO I etc.
6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex S6 G Or Elastoflex S6 G FR shall be fully asphalt -applied to the substrates
noted in Table 2. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course
to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately
3/8-inch beyond the lap edge.
6.6 Polyflex G or Polyflex G FR:
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use
in tile applications:
✓ Polyflex G is for use as an alternate to the Heat Applied 'Yap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-
12) beneath mechanically fastened or adhered tile roof systems (Refer to Table 2 for base sheet options).
✓ Polyflex G FR is for use as an alternate to the Heat Applied 'Yap Sheet' in the 'Two Ply System" from FRSA/TRI April 2012
(04-12) beneath mechanically fastened tile roof systems (Refer to Table 2 for base sheet options).
6.6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Table 2. Side laps shall be minimum 3-inch and
end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and
inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge.
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2
herein, and Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used on all roof
slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail -boards, to prevent tile
sliding and/or damage to the underlayment during the loading process.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the noted CIA agency for information on product locations covered for F.A.C. 61G20-3 CIA requirements. Refer to
Section 4 herein for product & production locations having met codified physical properties specifications.
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-112S
Clatficatea14etho1irat)on A32455 6^i EDITION 120171 F8C NON-HVHZ EVALUATION F1.5259-1129
Polyglass Roof Underlayments; (9541233.1230 Revision 25: 10/14/2019
Page 16 of 16