Loading...
HomeMy WebLinkAboutProduct Approval10/30/2019 Florida Building Code Online FL Y. FL27499-R1 Application Type Revision Code Version 2017 Application Status Approved Comments Archived ,.... Product Manufacturer Dynamic Metals Address/Phone/Email 3201 SE Dominica Terace Stuart, FL 34997 (772) 872-8030 juan@dynamicmetal.net Authorized Signature Lara Jesus juan@dynamicmetal.net Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Scott Wolters Evaluation Report Florida License PE-62354 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/31/2026 Validated By Lucas A. Turner, P.E., MBA efi Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL27499 RI COI Dyn COI pdf Standard Year TAS 100 1995 TAS 110 2003 TAS 125 2003 https://www.floridabuilding.org/pr/pr app_dtl. aspx? param=wGEVXQwtDq u H O E2Ywe%2 bOsCepABg3%2bkM6B4 KrS3X7m7 RLN DTr%2fv7QaQ %3d %... 1 /4 10/3012019 Florida Building Code Online Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. 27499.16 1 DM Class 2000 2" Mechanical Seam Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eva) report for Limits of Use. 27499.17 1 DM Class 500 5V Crimp Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use ,k 127499.18 DM Class 500 5V Crimp Installation Instructions FL27499 R1 II 2MRA18HZ.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499 Rl AE DM Eva115.(Ldf Created by Independent Third Party: Yes 24 Ga. galvalume coated steel roof panel, 18" wide, with 2" standing seams, Installation Instructions FL27499 Rl II 2MSS18HZ.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499 RI AE DM Evall6.pdf Created by Independent Third Party: Yes 26 Ga. galvalume coated steel roof panel, 24" wide, with SV crimp. Installation Instructions FL27499 Rl II 5VS.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499 R1 AE DM Eva117.pdf Created by Independent Third Party: Yes .p32" Aluminum roof panel, 24" wide, with 5V Crimp Limits of Use I Installation Instructions Approved for use in HVHZ: Yes FL27499 R1 II 5VAL.pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use FL27499 Rl AE DM Evall8.pdf Created by Independent Third Party: Yes 00 Contact Us :: 2601 ala, Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Floritla is an AA/EEO employer. Sopyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your a -mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an small address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made avallable to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . product Approval Accepts: https://www.fioridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM6B4KrS3X7m7RLN DTr%2fv7QaQ%3d%... 4/4 ENGINEERING, DRAFTING, CONSULTING 15211 9711 Road N West Palm Beach, Ft. 33412 Ph]Fx: (561) 225-1982 . • -1MJi��L1 • PRODUCT: DM CLASS 500 26 GA. GALVALUME 5V CRIMP 24" WIDE ROOF PANEL (FLPA# 27499.17) MANUFACTURER: DYNAMIC METALS, LLC 340 PIKE ROAD WEST PALM BEACH, FL 33411 To all concerned, The DM Class 500 Series 26 Ga, Galvalume 5V Crimp 24" Wide Roof Panel, manufactured by Dynamic Metals LLC, is a non-structural galvalume coated Fluropon painted steel roof panel (50 ksi min) that meets the requirements of Sections 1507A and 1518.9 of the 61h Edition (2017) Florida Building Code. The panel has been tested per TAS 100 and TAS 125 by Intertek with results shown in test reports G3443.38-450-44 and H2686.02- 450-44, and per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004- 02-01 and VLS-005-02-01. Technical Documentation: 1. Drawing "5VS-HZ" dated 8/15/19, signed and sealed by Scott Wolters, PE, 2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE, and by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE. 3. Supplemental Calculations to support "5VS-HZ" drawing, signed and sealed by Scott Wolters, PE. I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). Based on the limitations listed below and those provided in the documents above, this product meets all the requirements of the 61h Edition (2017) Florida Building Code generally, and chapter 15 specifically, including the HVHZ provisions. Limitations: This panel is approved for use inside and outside of the HVHZ. Overall Limitations: Maximum Panel Width: 24" (nominal) Fastener Spacing across panel: 12" (at Overlaps & Center Rib) Min, Slope: HVHZ: 2'712" Non-HVHZ: W712" (with Lap Sealant) 3"/12" (no Lap Sealant) SFFCIAI RING IN IMPACTFF515TANr CUl fAIMNAA,S, 5r0rEFFON1"5& UJINn00/5 Field Installation Perimeter & Corner Installation Max. Design Pressure: -117,75 psf -206 psf Fastener Spacing: 4" From Ends, 16" Max. O.C. 4" From Ends, 8" Max. O.C. Min Panel Fasteners: #10xl %2' HiLo HWH Screw with Weather -seal Washer #10xl ''/2" HiLo HWH Screw with Weather -seal Washer Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. (See note #2 below) Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent galvanic reactions. Underlavment: Minimum ASTM D 226 Type II with 4" overlaps and 6" end -laps, anchored with 12 Ga, x 1 V44" galvanized roof nails with 32 Ga. Tin caps spaced 6" O.C. in rows at the perimeter, at overlaps, and two intermediate rows staggered and spaced 12" O.C. (or) Any underlayment with a valid FLPA or Miami -Dade NOA Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent galvanic reactions. Minimum Substrate: /2 (15/32" min) 4-ply COX Plywood, nailed to 2x rafters spaced 24" max. O.C. with 8d ring -shank nails spaced 4" O.C. Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or 1515.2. 2. Fire classification is not a part of this evaluation. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3. Design of substrate is by others and is not a part of this evaluation. 4. Rational analysis, provided by a Florida licensed ArchitecUEngineer per FAS 61 G20.3.005(e), may be used for project specific approval by the local authorities having jurisdiction, 5, All panels shall be permanently labeled with the manfacturer's name and/or logo, and the following statement, "Dynamic Metals FL# 27499.17, DM Class 500". Sp CIA,IZING IN IMPACT PE5151AN( CLIprAINW&I 5, 5TOVPOW5, & WINPOW5 Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per approval of 3rd party QA provider, to the dimensions shown on Drawing 5VS-HZ: SSQ-6800617 SSQ-5150216 8SQ-6810617 SSQ-6690517 SSQ-4560615 SSQ-8681118 5VC-0490718 5VC-0360516 6VC-0521218 Re -Roofing: The DM Class 500 Series 26 Ga. Galvalume 5V Crimp 24" Wide Roof Panel may be installed over a single layer of existing asphalt shingles, provide the existing roof meets the requirements of Section 1521 (HVHZ) or Section 1511 (outside of HVHZ) of the Florida Building Code. If you have any questions or need more information concerning this approval please contact me. Thank you, C'0 o *Cott ND 62354 W/0*ters FL PE# 62354 b-0 Z A! J(, STyJ ATE OF IN 'V1,rV A 7F ACiNI-AINWA I ->, 5101'+-'1'T0N15, & 0JNV0VV5 nsl�� 4�� 14"aits ur nttrervflttie7okrr'7dvr4a ne, I -ctg (tq5} �lqj Iwzg 131 � $ml� uIft I SIVAN DINVNAG st cv Ey LU m CL M 0 uj J > .J 5