Loading...
HomeMy WebLinkAboutExtreme 5V Crimp copy 21/4/2016 Florida Building Code Online BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff SCIS Site Map Links Se a __ _ Product Approval bpr USER: Public User Product Approval Menu > Product or Application Search > ADDiication Lis[ > Application Detail FL # FL17022-R7 Application Type Revision Code Version 2017 Application Status Approved Comments 08/18/2017v. date reapply 08/21/17 Archived Product Manufacturer Extreme Metal Fabricators, LLC Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 fivalidation@yahoo.com Authorized Signature Richard McKuhen flvalidation@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 richard@emfab.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Flc Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed LOCKE BOWDEN the Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R. Priest, P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP SSE Odf Referenced Standard and Year (of Standard) Standa_rg Year TAS 125 2003 UL1897 2012 UL 580 2006 Equivalence of Product Standards Certified By https:tlwww,floHdabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aBOp HpQQe6rMZMkU EoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 114 1 /412018 Florida Building Code Online Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/18/2017 Date Validated 08/25/2017 Date Pending FBC Approval 08/28/2017 Date Approved 10/10/2017 of Products IFL # I Model, Number or Name I Description 17022.1 1 p' ( ) 1 - "5V Grim R6 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions. Install the assembly in compliance with the installation method listed In this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.2 2 - "5V Crimp" (R6) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant. No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FaC. Refer to manufacturer's installation instructions. 17022.3 3 - "1.5" Mechanical Seam" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck wil fasteners Installation Instructions FL17022 R7 II FL 17022.1 5 V CRIMP ssr, f Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.1 5 V CRIMP ssr. f Created by Independent Third Party: Yes 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof pa mechanically attached to 15/32" plywood or Wood Deck wil exposed fasteners Installation Instructions FLI 7022 R7 II FL 17Q22.2 5 V CRIMP 0.032 ALUM ssr.p Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.2 5 V CRIMP .032 ALUM ssr. Created by Independent Third Party: Yes 1.5" rib height, 16" wide, 24 gauge steel, standing seam rc panel mechanically attached to 15/32" plywood or wood de with clips and fasteners. Installation Instructions FL17022 R7 II FL 17022.3 1.5 MECHANIC am 24 a ssr. df Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 FL 74 Z 1.5 MECHANICAL cp 4 ssr.ndf Created by Independent Third Party: Yes 17022.4 4 - "1.5" Mechanical Seam" (R5) 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32' plywood or Wo( Deck with clips and fasteners. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliante with applicable code installation method listed in this report and sections of FBC. Refer to manufacturer's installation instructions. Installation Instructions FL17022 R7 II FL 17022.4 MECHANCIAL SEAM ALUMINUM ssrpd Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 1702 4 --NCIAL SEAM A MiNUM S$r.09f Created by Independent Third Party: Yes 17022.5 15 - "1 in. Nail Strip" (R5) 1" rib height, 16" wide, z6 gauge steel, standing seam roof _ _._.....- -- n, n.. i ram.. G CnkP Wi r-n%1r)nv(;An%3d%3d 2J4 1 /4/2018 Florida Building Code Online panel mechanically attached to I5/3r, plywoop or wpoa ae j with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.5 1.0 NAILS R P ssr.pdf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.12df limitations of use. Install the assembly in compliance with the Created by Independent Third Party: Yes installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.6 6 - "1 in. Nail Strip" (115) 1" rib height, 16" wide, 0.032" aluminum, standing seam rl panel mechanically attached to attached to 15/32" plywooc Wood Deck with fasteners, Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.61.0 NAIL STRIP 0.032 ALUM ssrndf Approved for use outside HVHZ: Yes Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and Evaluation Reports limitations of use. Install the assembly in compliance with the FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032 Installation method listed in this report and applicable code ALUM ssr.pdf sections of FBC. Refer to manufacturer's installation Created by Independent Third Party: Yes instructions. 17022.7 7 - "1.5 in. Nail Strip" (R5) 1.5" rib height, 19" wide, 26 gauge steel, standing seam rc panel mechanically attached to 15/32" plywood or wood de with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17 22.7 1.5 Nail Strip 26GA sr f Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and Evaluation Reports FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GGA ssr•pdf limitations of use. Install the assembly in compliance with the j Created by Independent Third Party: Yes installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.8 8 - "EMAX Rib" (R5) 29 gauge steel, lapped roof panel mechanically attached to I 15/32" plywood or wood deck with exposed fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 177022.8 EMAX Rib ssrndf Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No i Created by Independent Third Party: Yes Evaluation Reports Design Pressure: +N/A/ Table A Other: Refer to evaluation report for conditions and 1 FL17022 R7 AE FL 177022.8 EMAX Rib ssr.pdf ! Created by Independent Third Party: Yes limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code j j sections of FBC. Refer to manufacturer's installation instructions. 17022.9 9 - " PBR MAX" (115) 26 gauge steel, lapped roof panel mechanically attached to I 15/32" plywood or wood deck with exposed fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FI 17022 R7 II FL 17922.9 PBR RIB ssrndf i Verified B Locke Bowden, P.E. 49704 Approved far use outside HVHZ: Yes I Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports f Other: Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.9 RI ssr. by Independent Third Party: Yes limitations of use. Install the assembly in compliance with the i Created installation method listed in this report and applicable code ! sections of FBC. Refer to manufacturer's installation instructions. _. Contact VS :: 2601 Blair Stone Load, Tallahassee FL 3 399 Phone: 850-487-1824 The State of 90rida is an AA/EFO employer. COM nht 2007-2013 State of Floridel, :: r v to ent :: Accessibility Statemrrit Refund Statement L,44-�-th.n.n,141.,r;r4�hu;lrlinn nrntnr/nr Ann dtl.asox?Daram=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 3/4 Palm City, FL 34990 Compliant with Florida Building Code 2017 (6" ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ min. 0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec.1507. See Fastener attachment specifications above Install Details: Table A Allowable Loads_ METHOD 1 METHOD 2 METHOD 3 METHOD 4 DESIGN PRESSURE* �r -96 PSF -93.5 PSF -101 PSF -228 PSF ROW SPACING O.C. 16" o.c. 8" O.C. 6" o.c. FASTENER SPACING (ALONG Panel width) 12" o.c. 12" O.C. 12" o.c. 12" o.c. FASTENER SIZE 1 #9 #10 #10 #10 Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527 UL 580-06 & 2897-041 Test Report CM893.01-450-18 05/02/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897- j t l r *Design pressure margin of safety 2:1 .01 Locke Bowden, P.E. does not have, not will acquire a financial int i1 Q sj cQ q�m?�facturing or distributing products r • a ! •i u nd er this evaluation. �� ;'y L ' Locke Bowden, P.E. is not owned, operated, or controlled by a01 coi;pa►N;)n fiifaLtur;s, or distributing products under this report. * � •'kJ ~..fir ++� SLR,` • . • . � W? ,. FL17022.1 5V Crimp (26GA Steel), 24" Wide Roof Panel -Details Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 61h ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6m ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities wljurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance wIFBC 2017 Vh ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. 1332' or greater RYWOrod. or Wood plank A, 30 i v GFT€ MLVRAAMONS Panel Profile Nominal 12" Nominal 12" Fasten .9 X 1-112" Min. or #10 X 1-112" Min. per Table "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Width Panel Refer to Table "A" for Spacing Along Panel Overlap Length Deck-15132" or greater Plywood, or -Wood plank