HomeMy WebLinkAboutFL10497_R6_II_2017_09_FINAL_A1_ER_MULE-HIDE_FL10497-R6 copy 2
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017
Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 1 of 22
APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
Table Deck Application Type Description Page
1A Wood New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 4
1B-1 Wood New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 4
1B-2 Wood New, Reroof (Tear-Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5
1C Wood New, Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 6
1D Wood New, Reroof (Tear-Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 7
1E-1 Wood New or Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 8
1E-2 Wood New, Reroof (Tear-Off) or Recover E Non-Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 9
1F Wood New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 9
2A Steel or Conc. New, Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 10
2B Steel or Conc. New, Reroof (Tear-Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 11
3A Concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 12-14
3B Concrete New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 14
4A LWIC New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 15-16
4B LWIC New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 16
4C LWIC New or Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 17-18
5A CWF New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 19
5B CWF New, Reroof (Tear-Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 19
5C CWF New or Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 19
6A Gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 20
6B Gypsum Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 21
7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 21-22
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
Wood: Minimum 0.75-inch penetration.
Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer’s published installation instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum-based roof board or mineral-wool roof board that meets the QA
requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically atta ched base sheet, bonded roof cover), whereby the base
sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and
structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC
Approval documentation.
5. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016).
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017
Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 2 of 22
6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s published instructions.
Hot asphalt: Full coverage at 25-30 lbs/square.
Dow Insta-Stik Roofing Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c.
Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced.
OlyBond Classic (OB Classic): Full coverage at 1 gal/square.
ICP Adhesives CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c.
Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, board joints shall be staggered.
Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
7. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then
the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table:
Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick)
OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch thick Multi-Max FA-3)
OMG OlyBond 500 (OB500): MDP -187.5 psf (Min. 0.5-inch thick ISO 95+ GL)
OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3)
OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam II, Poly ISO 2)
ICP Adhesives CR-20: MDP -117.5 psf (Min. 1.0-inch thick)
8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.
9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss
Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for
Zone 2/3 enhancements.
10. For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no
rational analysis is permitted.
11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12. For existing substrates in a bonded recover or re-roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application.
14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC
Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-coat thickness is 2-inches.
For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1.
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017
Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 3 of 22
15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications.
TABLE 1: MULE-HIDE ROOF COVERS
Reference Layer Material Application
SBS-SA
(SBS, Self-Adhering)
Base Ply One or more plies SA Base Sheet, SA Base Sheet (FR)
Self-Adhering Cap SA-SBS Cap Sheet, SA-SBS Cap Sheet (FR)
Note: Self-adhering membranes shall not be installed over APP-TA membranes.
APP-TA
(APP, Torch-Applied)
Base Ply or Ply One or more plies APP Torch Base, APP Torch S Torch-Applied Cap APP Torch S, APP Torch G, APP Torch G FR, APP Torch KoolCap G, APP Torch KoolCap G FR
APP-SA
(APP, Self-Adhering)
Cap SA-APP Cap Sheet, SA-APP Cap Sheet (FR), SA-APP KoolCap G, SA-APP KoolCap G (FR) Self-Adhering Note: Self-adhering membranes shall not be installed over APP-TA membranes.
16. Any FBC Approved coating listed for use with SBS or APP modified bitumen roofing may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing
Materials Directory for fire ratings associated with coating usage.
17. Dens Deck shall be field-primed with PG100 prior to self-adhering membrane application. Refer to tables herein for other priming requirements.
18. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in Table 3A
applies:
VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; ADHERED INSULATION PER TABLE 3A
Option # Primer Vapor Barrier Insulation Adhesive MDP (psf) Type Attach
VB-1. Mule-Hide 121 SA Base Sheet Self-Adhering Inta-Stik or CR-20, 12-inch o.c. -60.0
VB-2. Mule-Hide 121 APP Torch Base Torch-applied Inta-Stik or CR-20, 12-inch o.c. -75.0
VB-3. Mule-Hide 121 SA-SBS Cap Sheet Self-Adhering Insta-Stik, 12-inch o.c. -75.0
VB-4. Mule-Hide 121 SA-SBS Cap Sheet Self-Adhering Millennium One Step Foamable Adhesive, 12-inch o.c. -157.5
VB-5. Mule-Hide 121 SA-SBS Cap Sheet Self-Adhering CR-20, 12-inch o.c. -270.0
VB-6. Mule-Hide 121 SA Base Sheet, SA Base Sheet (FR) Self-Adhering Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade
Adhesive, OlyBond 500 or CR-20, 12-inch o.c. -290.0
19. ”MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017
Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 4 of 22
TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap
W-1 Min. 15/32-
inch plywood
Min. 1.5-inch ACFoam II, ACFoam III, ENRGY-3, H-
Shield, H-Shield CG, Multi-Max FA3
D-IS, M-OSFA,
OB500 or CR-20
(Optional) additional
layers(s) of base insulation
D-IS, M-OSFA,
OB500 or CR-20 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -52.5
TABLE 1B-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Type Attach Type Attach Base
Ply Ply Cap
TORCH-APPLIED BASE PLY:
W-2
Min. 19/32-
inch
plywood
Polyglass G2 Base,
CertainTeed Glasbase,
Firestone MB Base, JM
Perma-Ply 28, Tamko
Glass Base, GAFGLAS #75
32 ga., 1-5/8-
inch diameter tin
caps with 11 ga.
annular ring
shank nails
8-inch o.c. in 4-inch
lap and 8-inch o.c.
in three (3), equally
spaced, staggered
center rows
(Optional) Min. 1.5-
inch ACFoam II,
Poly ISO 2, ENRGY-
3, H-Shield, Poly
ISO 2, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens
Deck, Dens Deck Prime,
SECUROCK Gypsum-
Fiber Roof Board
Hot
asphalt APP-TA (Optional)
APP-TA APP-TA -60.0
W-3
Min. 15/32-
inch
plywood
Polyglass G2 Base Simplex MAXX
Cap
9-inch o.c. in 4-inch
lap and 9-inch o.c.
in four (4), equally
spaced, staggered
center rows
(Optional) Min. 1.5-
inch ACFoam II,
Poly ISO 2, ENRGY-
3, H-Shield, Poly
ISO 2, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens
Deck Prime, SECUROCK
Gypsum-Fiber Roof
Board
Hot
asphalt APP-TA (Optional)
APP-TA APP-TA -82.5
W-4
Min. 15/32-
inch
plywood
Polyglass G2 Base
32 ga., 1-5/8-
inch diameter tin
caps with 12 ga.
annular ring
shank nails
6-inch o.c. in 4-inch
lap and 6-inch o.c.
in five (5) equally
spaced, staggered
center rows
(Optional) Min. 1.5-
inch ACFoam II,
Poly ISO 2, ENRGY-
3, H-Shield, Poly
ISO 2, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens
Deck Prime, SECUROCK
Gypsum-Fiber Roof
Board
Hot
asphalt APP-TA (Optional)
APP-TA APP-TA -90.0
SELF-ADHERING BASE PLY:
W-5
Min. 19/32-
inch
plywood
Polyglass G2 Base,
CertainTeed Glasbase,
Firestone MB Base, JM
Perma-Ply 28, Tamko
Glass Base, GAFGLAS #75
32 ga., 1-5/8-
inch diameter tin
caps with 11 ga.
annular ring
shank nails
8-inch o.c. in 4-inch
lap and 8-inch o.c.
in three (3), equally
spaced, staggered
center rows
(Optional) Min. 1.5-
inch ACFoam II,
Poly ISO 2, ENRGY-
3, H-Shield, Poly
ISO 2, H-Shield CG,
Multi-Max FA3
Hot asphalt
Min. 0.25-inch Dens
Deck, Dens Deck Prime,
SECUROCK Gypsum-
Fiber Roof Board
Hot
asphalt SBS-SA
(Optional)
SBS-SA, APP-
TA
SBS-SA,
APP-SA,
APP-TA
-60.0
W-6
Min. 19/32-
inch
plywood
Nail Base
32 ga., 1-5/8-
inch diameter tin
caps with 12 ga.
annular ring
shank nails
6-inch o.c. in 4-inch
lap and 6-inch o.c.
in four (4), equally
spaced, staggered
center rows
Min. 2-inch
ACFoam II, Poly ISO
2, ACFoam III, H-
Shield, Poly ISO 1,
H-Shield CG, Multi-
Max FA3, ENRGY-3
D-IS, OB500,
CR-20, M-
OSFA, atop
fastener
rows, 7-inch
o.c.
(Optional) Additional
layers of base insulation
D-IS,
OB500,
CR-20,
M-OSFA
SBS-SA
(Optional)
SBS-SA, APP-
TA
SBS-SA,
APP-SA,
APP-TA
-60.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017
Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 5 of 22
TABLE 1B-2: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP
(psf) Type Fasten Attach Type Attach Type Attach Base
Ply Ply Cap
TORCH-APPLIED BASE PLY:
W-7 Min. 19/32-
inch plywood Nail Base OMG Flat Bottom Plates
(square) with Roofgrip #12
12-inch o.c. in 4-inch
lap and 12-inch o.c.
in two (2), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
ACFoam II, Poly ISO 2,
ENRGY-3, H-Shield, Poly
ISO 2, H-Shield CG, Multi-
Max FA3
Hot
asphalt
Min. 0.25-inch Dens
Deck, Dens Deck Prime,
SECUROCK Gypsum-
Fiber Roof Board
Hot
asphalt APP-TA (Optional)
APP-TA APP-TA -60.0
W-8 Min. 15/32-
inch plywood
Polyglass
G2 Base
Dekfast Hex Plates with
Dekfast #14, OMG 3”
Round Metal Plate with
OMG HD, OMG Flat
Bottom Plate (Accutrac)
with Roofgrip #14 or
Trufast 3” Metal Insulation
Plate with Trufast HD.
9-inch o.c. in 4-inch
lap and 9-inch o.c. in
four (4), equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
ACFoam II, Poly ISO 2,
ENRGY-3, H-Shield, Poly
ISO 1, H-Shield CG, Multi-
Max FA3
Hot
asphalt
Min. 0.25-inch Dens
Deck, Dens Deck Prime,
SECUROCK Gypsum-
Fiber Roof Board
Hot
asphalt APP-TA (Optional)
APP-TA APP-TA -82.5
SELF-ADHERING BASE PLY:
W-9 Min. 19/32-
inch plywood Nail Base OMG Flat Bottom Plates
(square) with Roofgrip #12
12-inch o.c. in 4-inch
lap and 12-inch o.c.
in two, equally
spaced, staggered
center rows
(Optional) Min. 1.5-inch
ACFoam II, Poly ISO 2,
ENRGY-3, H-Shield, Poly
ISO 2, H-Shield CG, Multi-
Max FA3
Hot
asphalt
Min. 0.25-inch Dens
Deck, Dens Deck Prime,
SECUROCK Gypsum-
Fiber Roof Board
Hot
asphalt SBS-SA
(Optional)
SBS-SA, APP-
TA
SBS-SA,
APP-SA,
APP-TA
-60.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017
Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 6 of 22
TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten Attach Base Ply Ply Cap
TORCH-APPLIED BASE PLY:
W-10 Min. 15/32-
inch plywood
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch Dens Deck
Prime or SECUROCK
Gypsum-Fiber Roof Board
Dekfast Hex Plates with Dekfast #14,
OMG 3” Round Metal Plate with OMG
HD, OMG Flat Bottom Plate (Accutrac)
with Roofgrip #14 or Trufast 3” Metal
Insulation Plate with Trufast HD.
1 per 2
ft2 APP-TA (Optional) APP-TA APP-TA -30.0
SELF-ADHERING BASE PLY:
W-11 Min. 15/32-
inch plywood
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch Dens Deck
Prime or SECUROCK
Gypsum-Fiber Roof Board
Dekfast Hex Plates with Dekfast #14,
OMG 3” Round Metal Plate with OMG
HD, OMG Flat Bottom Plate (Accutrac)
with Roofgrip #14 or Trufast 3” Metal
Insulation Plate with Trufast HD.
1 per 2
ft2 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -30.0
W-12 Min. 19/32-
inch plywood
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch ENRGY 3, H-
Shield, Poly ISO 1, Polytherm
Dekfast Galvalume Steel Hex with Dekfast
#12 DP or Mule-Hide 3” Insulation Plate
with Mule-Hide Drill Point Fastener
1 per
1.33 ft2 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -82.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017
Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 7 of 22
TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No. Deck (Note 1) Insulation Layer(s) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Base Fasten Attach Base Ply Cap
TORCH-APPLIED BASE PLY:
W-13 Min. 19/32-
inch plywood
One or more
layers, any
combination
Prelim.
Attached
Nail Base, Polyglass G2 Base,
CertainTeed Glasbase, Firestone MB
Base, JM Perma-Ply 28, Tamko Glass
Base or GAFGLAS #75
OMG Flat Bottom Plates (square)
with Roofgrip #14, Dekfast Hex with
Dekfast #14 or Trufast 3” Metal
Insulation Plate with Trufast HD
12-inch o.c. in 4-inch lap and 12-
inch o.c. in two (2), equally
spaced, staggered center rows
(Optional) APP-TA APP-TA -52.5
W-14 Min. 19/32-
inch plywood
One or more
layers, any
combination
Prelim.
Attached Nail Base OMG Flat Bottom Plates (square)
with Roofgrip #12
12-inch o.c. in 4-inch lap and 12-
inch o.c. in two (2), equally
spaced, staggered center rows
(Optional) APP-TA APP-TA -60.0
W-15 Min. 15/32-
inch plywood
One or more
layers, any
combination
Prelim.
Attached Polyglass G2 Base, Nail Base
Dekfast Hex Plates with Dekfast
#14, OMG 3” Round Metal Plate
with OMG HD, OMG Flat Bottom
Plate (Accutrac) with Roofgrip #14
or Trufast 3” Metal Insulation Plate
with Trufast HD.
10-inch o.c. in 4-inch lap and 10-
inch o.c. in three (3), equally
spaced, staggered center rows
(Optional) APP-TA APP-TA -75.0
W-16 Min. 15/32-
inch plywood
One or more
layers, any
combination
Prelim.
Attached Polyglass G2 Base, Nail Base
Dekfast Hex Plates with Dekfast
#14, OMG 3” Round Metal Plate
with OMG HD, OMG Flat Bottom
Plate (Accutrac) with Roofgrip #14
or Trufast 3” Metal Insulation Plate
with Trufast HD.
9-inch o.c. in 4-inch lap and 9-
inch o.c. in four (4), equally
spaced, staggered center rows
(Optional) APP-TA APP-TA -90.0
SELF-ADHERING BASE PLY:
W-17 Min. 19/32-
inch plywood
One or more
layers, any
combination
Prelim.
Attached Nail Base
Dekfast Hex with Dekfast #14 or
Mule-Hide 3” Insulation Plate with
Mule-Hide HDP Fastener
12-inch o.c. in 4-inch lap and 12-
inch o.c. in two (2), equally
spaced, staggered center rows
SBS-SA
SBS-SA,
APP-SA,
APP-TA
-52.5*
W-18 Min. 19/32-
inch plywood
One or more
layers, any
combination
Prelim.
Attached Nail Base OMG Flat Bottom Plates (square)
with Roofgrip #12
12-inch o.c. in 4-inch lap and 12-
inch o.c. in two (2), equally
spaced, staggered center rows
SBS-SA
SBS-SA,
APP-SA,
APP-TA
-60.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017
Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 8 of 22
TABLE 1E-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILS), BONDED ROOF COVER
System
No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Base Fasten Attach Base Ply Cap
TORCH-APPLIED BASE PLY:
W-19 Min. 15/32-
inch plywood Nail Base Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two (2),
equally spaced, staggered center rows (Optional) APP-TA APP-TA -45.0*
W-20 Min. 15/32-
inch plywood Nail Base Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two (2),
equally spaced, staggered center rows (Optional) APP-TA APP-TA -52.5
W-21 Min. 15/32-
inch plywood APP Torch Base, Nail Base Original Simplex Cap Nails (1-inch metal head diameter,
11 gauge x min. 1.25-inch long annular grooved shank)
6-inch o.c. at 3-inch lap and 6-inch o.c. in four (4),
equally spaced, staggered center rows (Optional) APP-TA APP-TA -52.5
W-22 Min. 19/32-
inch plywood
Nail Base, Polyglass G2 Base,
CertainTeed Glasbase, Firestone
MB Base, JM Perma-Ply 28, Tamko
Glass Base or GAFGLAS #75
32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails
8-inch o.c. in 4-inch lap and 8-inch o.c. in three (3),
equally spaced, staggered center rows (Optional) APP-TA APP-TA -60.0
W-23 Min. 15/32-
inch plywood Polyglass G2 Base, Nail Base 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails
8-inch o.c. in 4-inch lap and 8-inch o.c. in four (4),
equally spaced, staggered center rows (Optional) APP-TA APP-TA -67.5
W-24 Min. 15/32-
inch plywood Polyglass G2 Base, Nail Base Simplex MAXX Cap 10-inch o.c. in 4-inch lap and 10-inch o.c. in three
(3), equally spaced, staggered center rows (Optional) APP-TA APP-TA -75.0
W-25 Min. 15/32-
inch plywood Polyglass G2 Base, Nail Base Simplex MAXX Cap 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4),
equally spaced, staggered center rows (Optional) APP-TA APP-TA -90.0
W-26 Min. 15/32-
inch plywood Nail Base Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two (2),
equally spaced, staggered center rows (Optional) APP-TA APP-TA -90.0
W-27 Min. 15/32-
inch plywood Elastobase Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three (3),
equally spaced, staggered center rows (Optional) APP-TA APP-TA -105.0
W-28 Min. 19/32-
inch plywood Elastobase or Elastobase Poly 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails
6-inch o.c. in 4-inch lap and 6-inch o.c. in four (4),
equally spaced, staggered center rows (Optional) APP-TA APP-TA -112.5
SELF-ADHERING BASE PLY:
W-29 Min. 15/32-
inch plywood Nail Base Original Simplex Cap Nails (1-inch metal head diameter,
11 gauge x min. 1.25-inch long annular grooved shank)
6-inch o.c. at 3-inch lap and 6-inch o.c. in four,
equally spaced, staggered center rows (Optional) SBS-SA SBS-SA, APP-
SA, APP-TA -52.5
W-30 Min. 19/32-
inch plywood Nail Base 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails
8-inch o.c. in 4-inch lap and 8-inch o.c. in three,
equally spaced, staggered center rows (Optional) SBS-SA SBS-SA, APP-
SA, APP-TA -60.0
W-31 Min. 19/32-
inch plywood Nail Base 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails.
4-inch o.c. in 4-inch lap and 4-inch o.c. in four,
equally spaced, staggered center rows (Optional) SBS-SA SBS-SA, APP-
SA, APP-TA -97.5
W-32 Min. 19/32-
inch plywood Nail Base
32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails. Note: Tin caps are to be primed with
Mule-Hide 121 or ASTM D41 primer.
6-inch o.c. in 4-inch lap and 6-inch o.c. in four,
equally spaced, staggered center rows (Optional) SBS-SA SBS-SA, APP-
SA, APP-TA -112.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017
Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 9 of 22
TABLE 1E-2: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER
System
No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Base Fasten Attach Base Ply Cap
TORCH-APPLIED BASE PLY:
W-33 Min. 19/32-
inch plywood
Nail Base, Polyglass G2 Base,
CertainTeed Glasbase, Firestone
MB Base, JM Perma-Ply 28, Tamko
Glass Base or GAFGLAS #75
OMG Flat Bottom Plates (square) with Roofgrip
#14, Dekfast Hex with Dekfast #14 or Trufast 3”
Metal Insulation Plate with Trufast HD
12-inch o.c. in 4-inch lap and 12-inch o.c. in two
(2), equally spaced, staggered center rows (Optional) APP-TA APP-TA -52.5
W-34 Min. 19/32-
inch plywood Nail Base OMG Flat Bottom Plates (square) with Roofgrip
#12
12-inch o.c. in 4-inch lap and 12-inch o.c. in two
(2), equally spaced, staggered center rows (Optional) APP-TA APP-TA -60.0
W-35 Min. 15/32-
inch plywood Polyglass G2 Base, Nail Base
Dekfast Hex Plates with Dekfast #14, OMG 3”
Round Metal Plate with OMG HD, OMG Flat
Bottom Plate (Accutrac) with Roofgrip #14 or
Trufast 3” Metal Insulation Plate with Trufast HD.
10-inch o.c. in 4-inch lap and 10-inch o.c. in three
(3), equally spaced, staggered center rows (Optional) APP-TA APP-TA -75.0
W-36 Min. 15/32-
inch plywood Polyglass G2 Base, Nail Base
Dekfast Hex Plates with Dekfast #14, OMG 3”
Round Metal Plate with OMG HD, OMG Flat
Bottom Plate (Accutrac) with Roofgrip #14 or
Trufast 3” Metal Insulation Plate with Trufast HD.
9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4),
equally spaced, staggered center rows (Optional) APP-TA APP-TA -90.0
W-37 Min. 15/32-
inch plywood APP Torch Base or Nail Base
OMG #12 Standard Roofgrip or OMG #14 Heavy
Duty (min. 1-5/8-inch long) with OMG 3” Round
Metal Plates or OMG Flat Bottom Metal Plates
6-inch o.c. at 4-inch lap and 6-inch o.c. in three
(3), equally spaced, staggered center rows (Optional) APP-TA APP-TA -90.0
W-38 Min. 15/32-
inch plywood APP Torch Base or Nail Base
OMG #12 Standard Roofgrip or OMG #14 Heavy
Duty (min. 1-5/8-inch long) with OMG 3” Round
Metal Plates or OMG Flat Bottom Metal Plates
6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5),
equally spaced, staggered center rows (Optional) APP-TA APP-TA -120.0
SELF-ADHERING BASE PLY:
W-39 Min. 19/32-
inch plywood Nail Base Dekfast Hex with Dekfast #14 or Mule-Hide 3”
Insulation Plate with Mule-Hide HDP Fastener
12-inch o.c. in 4-inch lap and 12-inch o.c. in two,
equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA,
APP-TA -52.5*
W-40 Min. 19/32-
inch plywood Nail Base OMG Flat Bottom Plates (square) with Roofgrip
#12
12-inch o.c. in 4-inch lap and 12-inch o.c. in two,
equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA,
APP-TA -60.0*
TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
System
No. Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Joint Treatment Base Ply Ply Cap
W-41 Min. 15/32-
inch plywood (Optional) Mule-Hide 121 None SBS-SA (Optional) SBS-SA, APP-
TA
SBS-SA, APP-SA, APP-
TA -90.0
W-42 Min. 15/32-
inch plywood (Optional) Mule-Hide 121 Plywood joints are covered with minimum 4-inch wide strips of SA Base Sheet,
rolled into place to create continuous bond. SBS-SA (Optional) SBS-SA, APP-
TA
SBS-SA, APP-SA, APP-
TA -135.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017
Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 10 of 22
TABLE 2A: STEEL OR CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No. Deck (Note 1) Base Insulation
Layer
Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten Attach Base Ply Ply Cap
SC-1.
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or
more layers, any
combination, loose
laid
Min. 1.5-inch ACFoam II, Poly ISO
2, H-Shield, Poly ISO 1
Dekfast Galvalume Steel Hex with Dekfast
#12 DP (steel only) or Dekfast #14, OMG
AccuTrac Flat Bottom Plate with #12
Roofgrip (steel only) or OMG #14 Heavy
Duty, Trufast 3” Metal Insulation Plate with
Trufast #12 DP (steel only) or Trufast #14 HD
1 per 2.67
ft2 SBS-SA (Optional) SBS-SA,
APP-TA
SBS-SA,
APP-SA,
APP-TA
-30.0
SC-2.
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or
more layers, any
combination, loose
laid
Min. 1.5-inch H-Shield, Poly ISO 1,
Polytherm
OMG AccuTrac Flat Bottom Plate with #12
Roofgrip (steel only) or OMG #14 Heavy Duty
Trufast 3” Metal Insulation Plate with Trufast
#12 DP (steel only) or Trufast #14 HD
1 per 2 ft2 SBS-SA (Optional) SBS-SA,
APP-TA
SBS-SA,
APP-SA,
APP-TA
-45.0*
SC-3.
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or
more layers, any
combination, loose
laid
Min. 1.5-inch H-Shield, Poly ISO 1,
Polytherm
Dekfast Galvalume Steel Hex with Dekfast
#12 DP (steel only) or Dekfast #14 1 per 2 ft2 SBS-SA (Optional) SBS-SA,
APP-TA
SBS-SA,
APP-SA,
APP-TA
-60.0
SC-4.
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or
more layers, any
combination, loose
laid
Min. 1.5-inch ENRGY 3, H-Shield,
Poly ISO 1, Polytherm
Dekfast Galvalume Steel Hex with Dekfast
#12 (steel only) or #14 or Mule-Hide 3”
Insulation Plate with Mule-Hide Drill Point
Fastener (steel only) or Mule-Hide HDP
Fastener
1 per 1.33
ft2 SBS-SA (Optional) SBS-SA,
APP-TA
SBS-SA,
APP-SA,
APP-TA
-82.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017
Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 11 of 22
TABLE 2B: STEEL OR CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
NOTE: INSULATION IS OPTIONAL FOR RECOVER APPLICATIONS
System
No.
Deck
(Note 1)
Insulation Layer(s) Base Sheet Roof Cover (Note 15) MDP
(psf) Type Attach Base Fasten Attach Base Ply Cap
SC-5.
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached
Nail Base or JM Perma-Ply
28
OMG Flat Bottom Plates (square) with
Roofgrip #14, Dekfast Hex with Dekfast
#14 or Trufast 3” Metal Insulation Plate
with Trufast HD
12-inch o.c. in 4-inch lap and 18-
inch o.c. in two, equally spaced,
staggered center rows
(Optional) APP-TA APP-TA -45.0*
SC-6.
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached
Nail Base, Polyglass G2 Base,
CertainTeed Glasbase,
Firestone MB Base, JM
Perma-Ply 28, Tamko Glass
Base or GAFGLAS #75
OMG Flat Bottom Plates (square) with
Roofgrip #14, Dekfast Hex with Dekfast
#14 or Trufast 3” Metal Insulation Plate
with Trufast HD
12-inch o.c. in 4-inch lap and 12-
inch o.c. in two, equally spaced,
staggered center rows
(Optional) APP-TA APP-TA -52.5
SC-7.
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached Nail Base
OMG Flat Bottom Plates (square) with
Roofgrip #14, Dekfast Hex with Dekfast
#14 or Mule-Hide 3” Insulation Plate
with Mule-Hide HDP Fastener
12-inch o.c. in 4-inch lap and 12-
inch o.c. in two, equally spaced,
staggered center rows
SBS-SA SBS-SA,
APP-SA -52.5*
SC-8.
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached Nail Base OMG Flat Bottom Plates (square) with
Roofgrip #12 (steel only) or #14
12-inch o.c. in 4-inch lap and 12-
inch o.c. in two, equally spaced,
staggered center rows
(Optional) APP-TA APP-TA -60.0
SC-9.
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached Nail Base OMG Flat Bottom Plates (square) with
Roofgrip #12 (steel only) or #14
12-inch o.c. in 4-inch lap and 12-
inch o.c. in two, equally spaced,
staggered center rows
SBS-SA SBS-SA,
APP-SA -60.0*
SC-10.
Min. 22 ga., type B, Grade
80 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached APP Torch S Dekfast isofast IF-2.375-AT Plates with
Dekfast #15 HS
12-inch o.c. withiin the 5-inch wide,
heat-welded side lap (Optional) APP-TA APP-TA -82.5
SC-11.
Min. 22 ga., type B, Grade
80 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached APP Torch S Trufast 2.4 in. Barbed Seam Plates with
Trufast EHD Fasteners
12-inch o.c. within the 6-inch wide,
heat-welded side lap (Optional) APP-TA APP-TA -82.5
SC-12.
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Prelim.
Attached APP Torch S
Dekfast Hex with Dekfast #14 or OMG
Flat Bottom Plates with OMG Roofgrip
#14
12-inch o.c. within the 4-inch lap
and 18-inch o.c. in two, equally
spaced, staggered center rows
(Optional) APP-TA APP-TA -112.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017
Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 12 of 22
TABLE 3A: CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 17
System
No.
Deck
(Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap
SELF-ADHERING BASE PLY WITH BASE INSULATION AND OPTIONAL TOP INSULATION OF THE SAME TYPE:
C-1 Concrete
(Optional)
Mule-Hide
121
Min. 1.5-inch H-Shield, Poly ISO 1, Multi-Max
FA3 D-IS (Optional) additional
layers(s) of base insulation D-IS SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -67.5
C-2 Concrete
(Optional)
Mule-Hide
121
Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3 D-IS (Optional) additional
layers(s) of base insulation D-IS SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -135.0
C-3 Concrete None Min. 1.5-inch, min. 1.5 pcf EPS insulation board D-IS (Optional) additional layers
of base insulation D-IS SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -157.5
C-4 Concrete None Min. 1.5-inch, min. 2.0 pcf EPS insulation board OB500 (Optional) additional layers
of base insulation OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -120.0
C-5 Concrete None Min. 1.5-inch ENRGY 3 OB500 (Optional) additional
layers(s) of base insulation OB500 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -127.5
C-6 Concrete None Min. 1.5-inch ACFoam II, Poly ISO 2, H-Shield,
Poly ISO 1 OB500 (Optional) additional
layers(s) of base insulation OB500 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -150.0
C-7 Concrete None Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3,
H-Shield, Poly ISO 1, Multi-Max FA3 M-OSFA (Optional) additional
layers(s) of base insulation M-OSFA SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -232.5
C-8 Concrete None Min. 1.5-inch, min. 2.0 pcf EPS insulation board CR-20 (Optional) additional layers
of base insulation CR-20 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -240.0
C-9 Concrete None
Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam III,
ENRGY 3, H-Shield, Poly ISO 1, H-Shield CG ,
Multi-Max FA3, ISO 95+ GL
CR-20 (Optional) additional
layers(s) of base insulation CR-20 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -270.0
C-10 Concrete None Min. 2-inch ACFoam II, Poly ISO 2, H-Shield, Poly
ISO 1 OB Classic (Optional) additional
layers(s) of base insulation
OB
Classic SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -270.0
C-11 Concrete Mule-Hide
121
Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam III,
ENRGY 3, H-Shield, Poly ISO 1, H-Shield CG,
Multi-Max FA3
Hot
asphalt
(Optional) additional
layers(s) of base insulation
Hot
asphalt SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -480.0
SELF-ADHERING BASE PLY WITH BASE INSULATION AND COVERBOARD:
C-12 Concrete None Min. 1.5-inch Multi-Max FA3 D-IS Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board D-IS SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -67.5
C-13 Concrete None
Min. 1.5-inch, min. 2.0 pcf ASTM C578
Expanded Polystyrene, ACFoam II, Poly ISO 2,
ENRGY 3 , H-Shield, Poly ISO 1
D-IS Min. 0.25-inch Dens Deck
Prime D-IS SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -72.5
C-14 Concrete None Min. 1.5-inch, min. 2.0 pcf ASTM C578
Expanded Polystyrene D-IS Min. 0.25-inch Dens Deck,
Dens Deck Prime D-IS SBS-SA (Optional) APP-TA APP-TA -120.0
C-15 Concrete None Min. 2-inch ACFoam II, Poly ISO 2, ENRGY-3, H-
Shield, Poly ISO 1 D-IS Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board D-IS SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -247.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017
Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 13 of 22
TABLE 3A: CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 17
System
No.
Deck
(Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap
C-16 Concrete None Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3,
H-Shield, Poly ISO 1 or ISO 95+GL OB500 Min. 0.25-inch Dens Deck
Prime OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -72.5
C-17 Concrete None Min. 1.5-inch ENRGY 3 OB500 Min. 0.25-inch Dens Deck,
Dens Deck Prime OB500 SBS-SA (Optional) APP-TA APP-TA -127.5
C-18 Concrete None Min. 1.5-inch ACFoam II, Poly ISO 2, H-Shield,
Poly ISO 1, ISO 95+GL OB500 Min. 0.25-inch Dens Deck,
Dens Deck Prime OB500 SBS-SA (Optional) APP-TA APP-TA -150.0
C-19 Concrete None Min. 2-inch ACFoam II, Poly ISO 2, ENRGY-3, H-
Shield, Poly ISO 1 OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -247.5
C-20 Concrete None Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3,
H-Shield, Poly ISO 1, Multi-Max FA3 M-OSFA Min. 0.25-inch Dens Deck
Prime M-OSFA SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -72.5
C-21 Concrete None Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3,
H-Shield, Poly ISO 1, Multi-Max FA3 M-OSFA Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board M-OSFA SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -232.5
C-22 Concrete None Min. 2-inch ACFoam II, Poly ISO 2, ENRGY-3, H-
Shield, Poly ISO 1 M-OSFA Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board M-OSFA SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -247.5
C-23 Concrete None Min. 1.5-inch, min. 2.0 pcf ASTM C578
Expanded Polystyrene CR-20 Min. 0.25-inch Dens Deck
Prime CR-20 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -72.5
C-24 Concrete None Min. 1.5-inch, min. 2.0 pcf ASTM C578
Expanded Polystyrene CR-20 Min. 0.25-inch Dens Deck,
Dens Deck Prime CR-20 SBS-SA (Optional) APP-TA APP-TA -240.0
C-25 Concrete None
Min. 1.5-inch Ultra-Max, Multi-Max FA-3, min.
1.3-inch ACFoam III or min. 1.0-inch ISO 95+GL,
H-Shield, Poly ISO 1, H-Shield CG, ENRGY 3
CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -240.0
C-26 Concrete None Min. 2-inch ACFoam II, Poly ISO 2, ENRGY-3, H-
Shield, Poly ISO 1 CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -247.5
C-27 Concrete None Min. 2-inch ACFoam II, Poly ISO 2, H-Shield, Poly
ISO 1 OB Classic Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
OB
Classic SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -350.0
C-28 Concrete Mule-Hide
121
Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam III,
ENRGY 3, H-Shield, Poly ISO 1, H-Shield CG,
Multi-Max FA3
Hot
asphalt
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Hot
asphalt SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -350.0
TORCH APPLIED BASE PLY:
C-29 Concrete None Min. 2-inch ACFoam II, Poly ISO 2, H-Shield, Poly
ISO 1 D-IS Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board D-IS APP-TA (Optional) APP-TA APP-TA -232.5
C-30 Concrete None Min. 2-inch ACFoam II, Poly ISO 2, H-Shield, Poly
ISO 1 OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 APP-TA (Optional) APP-TA APP-TA -232.5
C-31 Concrete None Min. 2-inch ACFoam II, Poly ISO 2, H-Shield, Poly
ISO 1 M-OSFA Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board M-OSFA APP-TA (Optional) APP-TA APP-TA -232.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017
Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 14 of 22
TABLE 3A: CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 17
System
No.
Deck
(Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap
C-32 Concrete None
Min. 1.5-inch Ultra-Max or Multi-Max FA-3,
min. 1.3-inch ACFoam III or min. 1.0-inch ISO
95+GL, H-Shield, Poly ISO 1, H-Shield CG or
ENRGY 3
CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 APP-TA (Optional) APP-TA APP-TA -232.5
C-33 Concrete None (Optional) Min. 2-inch ACFoam II, Poly ISO 2, H-
Shield, Poly ISO 1 OB Classic Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
OB
Classic APP-TA (Optional) APP-TA APP-TA -232.5
C-34 Concrete Mule-Hide
121
Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam III,
ENRGY 3, H-Shield, Poly ISO 1, H-Shield CG,
Multi-Max FA3
Hot
asphalt
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Hot
asphalt APP-TA (Optional) APP-TA APP-TA -232.5
TABLE 3B: CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED BASE SHEET, BONDED ROOF COVER
System No. Deck
(Note 1) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap
C-35 Concrete Mule-Hide 121 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -315.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017
Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 15 of 22
TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck (Note 1) Base Insulation Layer Coverboard Roof Cover (Note 15)
MDP (psf) Struct.
Deck LWC Type Attach Type Attach Base Ply Ply Cap
SELF-ADHERING BASE PLY WITH BASE INSULATION AND OPTIONAL TOP INSULATION OF THE SAME TYPE:
LWC-1 Concrete Min. 200 psi, min
2-inch Elastizell
Min. 1.5-inch, min. 2.0 pcf ASTM C578
expanded polystyrene OB500 (Optional) Additional layers
of base insulation OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -120.0
LWC-2 Concrete Min. 200 psi, min
2-inch Elastizell
Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY
3, ISO 95+ GL, H-Shield, Poly ISO 1 OB500 (Optional) Additional layers
of base insulation OB500 SBS-SA (Optional) SBS-SA, APP-
TA
SBS-SA, APP-SA,
APP-TA -225.0
LWC-3 Concrete Min. 200 psi, min.
2-inch Elastizell
Min. 1.5-inch, min. 2.0 pcf ASTM C578
expanded polystyrene CR-20 (Optional) Additional layers
of base insulation CR-20 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -180.0
LWC-4 Concrete Min. 200 psi, min.
2-inch Elastizell
Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam
III, ENRGY 3, ISO 95+ GL, H-Shield, Poly ISO 1,
H-Shield CG, Multi-Max FA3
CR-20 (Optional) Additional layers
of base insulation CR-20 SBS-SA (Optional) SBS-SA, APP-
TA
SBS-SA, APP-SA,
APP-TA -180.0
LWC-5 Concrete
Min. 200 psi, min.
2-inch Celcore or
Mearlcrete
Min. 1.5-inch, min. 2.0 pcf ASTM C578
expanded polystyrene CR-20 (Optional) Additional layers
of base insulation CR-20 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -222.5
LWC-6 Concrete
Min. 200 psi, min.
2-inch Celcore or
Mearlcrete
Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam
III, ENRGY 3, ISO 95+ GL, H-Shield, Poly ISO 1,
H-Shield CG, Multi-Max FA3
CR-20 (Optional) Additional layers
of base insulation CR-20 SBS-SA (Optional) SBS-SA, APP-
TA
SBS-SA, APP-SA,
APP-TA -222.5
SELF-ADHERING BASE PLY WITH BASE INSULATION AND COVERBOARD:
LWC-7 Concrete Min. 200 psi, min
2-inch Elastizell
Min. 1.5-inch, min. 2.0 pcf ASTM C578
expanded polystyrene OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA, APP-
TA
SBS-SA, APP-SA,
APP-TA -120.0
LWC-8 Concrete Min. 200 psi, min
2-inch Elastizell
Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY
3, ISO 95+ GL, H-Shield, Poly ISO 1 OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA, APP-
TA
SBS-SA, APP-SA,
APP-TA -225.0
LWC-9 Concrete Min. 200 psi, min.
2-inch Elastizell
Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam
III, ENRGY 3, ISO 95+ GL, H-Shield, Poly ISO 1,
H-Shield CG, Multi-Max FA3 or min. 2.0 pcf
ASTM C578 expanded polystyrene
CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, APP-
TA
SBS-SA, APP-SA,
APP-TA -180.0
LWC-10 Concrete
Min. 200 psi, min.
2-inch Celcore or
Mearlcrete
Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam
III, ENRGY 3, ISO 95+ GL, H-Shield, Poly ISO 1,
H-Shield CG, Multi-Max FA3 or min. 2.0 pcf
ASTM C578 expanded polystyrene
CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, APP-
TA
SBS-SA, APP-SA,
APP-TA -222.5
TORCH APPLIED BASE PLY:
LWC-11 Concrete Min. 200 psi, min
2-inch Elastizell
Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY
3, ISO 95+ GL, H-Shield, Poly ISO 1 OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 BP-AA, SBS-
AA, APP-TA
(Optional) BP-AA, SBS-
AA, SBS-TA or APP-TA
SBS-AA, SBS-TA,
APP-TA -225.0
LWC-12 Concrete Min. 200 psi, min.
2-inch Elastizell
Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam
III, ENRGY 3, ISO 95+ GL, H-Shield, Poly ISO 1,
H-Shield CG, Multi-Max FA3 or min. 2.0 pcf
ASTM C578 expanded polystyrene
CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 BP-AA, SBS-
AA, APP-TA
(Optional) BP-AA, SBS-
AA, SBS-TA or APP-TA
SBS-AA, SBS-TA,
APP-TA -180.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017
Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 16 of 22
TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck (Note 1) Base Insulation Layer Coverboard Roof Cover (Note 15)
MDP (psf) Struct.
Deck LWC Type Attach Type Attach Base Ply Ply Cap
LWC-13 Concrete
Min. 200 psi, min.
2-inch Celcore or
Mearlcrete
Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam
III, ENRGY 3, ISO 95+ GL, H-Shield, Poly ISO 1,
H-Shield CG, Multi-Max FA3 or min. 2.0 pcf
ASTM C578 expanded polystyrene
CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board CR-20 BP-AA, SBS-
AA, APP-TA
(Optional) BP-AA, SBS-
AA, SBS-TA or APP-TA
SBS-AA, SBS-TA,
APP-TA -222.5
TABLE 4B: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP
(psf) Struct LWC Type Fasten Attach Type Attach Type Attach Base Ply Ply Cap
LWC-14
Min. 22 ga.,
Type B, vented
steel at max. 5 ft
spans
Min. 300 psi
Approved
cellular LWC
GAFGLAS
#75
OMG CR
BSF
7-inch o.c. at 4-inch lap
and 7-inch o.c. in two,
equally spaced center
rows
Min. 1.5-inch ACFoam
II, Poly ISO 2, H-Shield,
Poly ISO 1, Multi-Max
FA3, Polytherm
Hot
asphalt None N/A SBS-SA (Optional) SBS-SA,
APP-TA
SBS-SA, APP-
SA, APP-TA -45.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017
Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 17 of 22
TABLE 4C: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP
(psf) Structural Deck Lightweight Concrete Type Fasten Attach Base Ply Cap
CELCORE CELLULAR LIGHTWEIGHT INSULATING CONCRETE:
LWC-15 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 225 psi, min. 2-inch thick
Celcore MF Polyglass G2 Base, Nail Base Trufast Twin
Loc-Nail
9-inch o.c. in a 4-inch lap and 18-inch o.c. in two,
equally spaced, staggered rows in the field of the sheet
(Optional)
APP-TA APP-TA -45.0
LWC-16 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 225 psi, min. 2-inch thick
Celcore MF Nail Base Trufast Twin
Loc-Nail
9-inch o.c. in a 4-inch lap and 18-inch o.c. in two,
equally spaced, staggered rows in the field of the sheet SBS-SA
SBS-SA,
APP-SA,
APP-TA
-45.0
LWC-17 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 300 psi, min. 2-inch thick
Celcore MF Nail Base Trufast FM-90 8-inch o.c. in a 4-inch lap and 8-inch o.c. in three
equally spaced, staggered center rows
(Optional)
APP-TA APP-TA -60.0
LWC-18 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 300 psi, min. 2-inch thick
Celcore MF Nail Base Trufast FM-90 8-inch o.c. in a 4-inch lap and 8-inch o.c. in three
equally spaced, staggered center rows SBS-SA
SBS-SA,
APP-SA,
APP-TA
-60.0
LWC-19 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 300 psi, min. 2-inch thick
Celcore
Polyglass G2 Base, Nail Base,
GAFGLAS #75, GAFGLAS Stratavent
Nailable Venting Base Sheet,
GAFGLAS Ply 4, GAFGLAS FlexPly 6,
JM Perma Ply No. 28, JM
Vensulation, JM GlasPly IV. GlasPly
Premier. Tamko Glass-Base, Tamko
Vapor-Chan
Trufast FM-90
or OMG CR BPF
7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, equally
spaced, staggered rows in the field of the sheet APP-TA APP-TA -75.0
LWC-20 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 300 psi, min. 2-inch thick
Celcore MF Nail Base Trufast FM-290 10-inch o.c. in a 4-inch lap and 10-inch o.c. in three
equally spaced, staggered center rows
(Optional)
APP-TA APP-TA -90.0
ELASTIZELL CELLULAR LIGHTWEIGHT INSULATING CONCRETE:
LWC-21
Min. 0.0179-inch Tensilform S-75
or min. 0.0205-inch Tensilform
75 at max. 5 ft spans or
structural concrete
Min. 200 psi, min. 2-inch thick
Elastizell Range II
Polyglass G2 Base, Nail Base,
GAFGLAS #75, GAFGLAS Stratavent
Nailable Venting Base Sheet,
GAFGLAS Ply 4, GAFGLAS FlexPly 6,
JM Perma Ply No. 28, JM
Vensulation, JM GlasPly IV. GlasPly
Premier. Tamko Glass-Base, Tamko
Vapor-Chan
Trufast FM-90
or OMG CR BPF
7.5-inch o.c. in a 3-inch lap and 7.5-inch o.c. in two,
equally spaced, staggered rows in the field of the sheet APP-TA APP-TA -30.0
LWC-22
Min. 0.0179-inch Tensilform S-75
or min. 0.0205-inch Tensilform
75 at max. 5 ft spans or
structural concrete
Min. 200 psi, min. 2-inch thick
Elastizell Range II Nail Base Trufast FM-90
or OMG CR BPF
7.5-inch o.c. in a 3-inch lap and 7.5-inch o.c. in two,
equally spaced, staggered rows in the field of the sheet SBS-SA
SBS-SA,
APP-SA,
APP-TA
-30.0
LWC-23 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 200 psi, min. 2-inch thick
Elastizell Range II
Polyglass G2 Base, Nail Base,
GAFGLAS #75, GAFGLAS Stratavent
Nailable Venting Base Sheet,
GAFGLAS Ply 4, GAFGLAS FlexPly 6,
JM Perma Ply No. 28, JM
Vensulation, JM GlasPly IV. GlasPly
Premier. Tamko Glass-Base, Tamko
Vapor-Chan
Trufast FM-90
or OMG CR BPF
7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, equally
spaced, staggered rows in the field of the sheet APP-TA APP-TA -45.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017
Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 18 of 22
TABLE 4C: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP
(psf) Structural Deck Lightweight Concrete Type Fasten Attach Base Ply Cap
LWC-24 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 200 psi, min. 2-inch thick
Elastizell Range II Nail Base Trufast FM-90
or OMG CR BPF
7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, equally
spaced, staggered rows in the field of the sheet SBS-SA
SBS-SA,
APP-SA,
APP-TA
-45.0
LWC-25
Min. 22 ga., type B vented steel
at max 5 ft spans or structural
concrete
Min. 350 psi, min. 2-inch thick
Elastizell with Zell-Crete
Fibers, supplemental attached
with Roofgrip #21 and 3-inch
plates at 1 per 8 ft2
Nail Base Trufast FM-290 8-inch o.c. in a 4-inch lap and 8-inch o.c. in three,
equally spaced, staggered rows in the field of the sheet
(Optional)
APP-TA APP-TA -52.5
LWC-26 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 350 psi, min. 2-inch thick
Elastizell with Zell-Crete
Fibers, supplemental attached
with Roofgrip #21 and 3-inch
plates at 1 per 8 ft2
Nail Base
Trufast Twin
Loc-Nails (min.
1.8-inch)
6-inch o.c. in a 4-inch lap and 6-inch o.c. in three,
equally spaced, staggered rows in the field of the sheet APP-TA APP-TA -60.0
LWC-27 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 350 psi, min. 2-inch thick
Elastizell with Zell-Crete
Fibers, supplemental attached
with Roofgrip #21 and 3-inch
plates at 1 per 8 ft2
Nail Base
Trufast Twin
Loc-Nails (min.
1.8-inch)
6-inch o.c. in a 4-inch lap and 6-inch o.c. in three,
equally spaced, staggered rows in the field of the sheet SBS-SA
SBS-SA,
APP-SA,
APP-TA
-60.0
MEARLCRETE CELLULAR LIGHTWEIGHT INSULATING CONCRETE:
LWC-28 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 300 psi, min. 2-inch thick
Mearlcrete
Polyglass G2 Base, Nail Base,
Tamko Vapor Chan
Trufast FM-90
or OMG CR BPF
7-inch o.c. in a 4-inch lap and 7-inch o.c. in two, equally
spaced, staggered rows in the field of the sheet APP-TA APP-TA -45.0
LWC-29 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 300 psi, min. 2-inch thick
Mearlcrete Nail Base Trufast FM-90
or OMG CR BPF
7-inch o.c. in a 4-inch lap and 7-inch o.c. in two, equally
spaced, staggered rows in the field of the sheet SBS-SA
SBS-SA,
APP-SA,
APP-TA
-45.0
LWC-30 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 300 psi, min. 2-inch thick
Mearlcrete
Polyglass G2 Base, Nail Base,
GAFGLAS #75, JM Perma Ply
No. 28, Tamko Glass-Base
Trufast FM-90
or OMG CR BPF
7-inch o.c. in a 4-inch lap and 7-inch o.c. in two, equally
spaced, staggered rows in the field of the sheet
BP-AA, SBS-
AA, SBS-TA,
or APP-TA
SBS-AA,
SBS-TA, or
APP-TA
-52.5
LWC-31 Min. 22 ga., type B steel at max 5
ft spans or structural concrete
Min. 300 psi, min. 2-inch thick
Mearlcrete Nail Base Trufast FM-90
or OMG CR BPF
7-inch o.c. in a 4-inch lap and 7-inch o.c. in two, equally
spaced, staggered rows in the field of the sheet SBS-SA
SBS-SA,
APP-SA,
APP-TA
-52.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017
Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 19 of 22
TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach Type Attach Base Ply Ply Cap
CWF-1 Min. 2.5-inch Tectum
Plank or Tectum LS Plank
Min. 1.5-inch ACFoam II, Poly ISO
2, ISO 95+GL, H-Shield, Poly ISO 1,
Polytherm, ENRGY-3
D-IS or
OB500
Min. 0.25-inch Dens Deck, Dens Deck Prime,
SECUROCK Gypsum-Fiber Roof Board D-IS or OB500 SBS-SA, APP-TA (Optional) SBS-SA,
APP-TA
SBS-SA,
APP-SA,
APP-TA
-45.0
CWF-2 Min. 2.5-inch Tectum
Plank or Tectum LS Plank
Min. 1.5-inch ACFoam II, Poly ISO
2, ISO 95+GL, H-Shield, Poly ISO 1,
Polytherm, ENRGY-3
CR-20 Min. 0.25-inch Dens Deck, Dens Deck Prime,
SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA, APP-TA (Optional) SBS-SA,
APP-TA
SBS-SA,
APP-SA,
APP-TA
-52.5
TABLE 5B: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten Attach Type Attach Type Attach Base Ply Ply Cap
CWF-3
Min. 2.5-inch
Tectum Plank
or Tectum LS
Plank
Nail Base,
Polyglass G2
Base
Trufast
Inuldek
Loc-Nail
9-inch o.c. in 4-inch
lap and 12-inch o.c.
in two, equally
spaced, staggered
center rows
Min. 1.5-inch ACFoam
II, Poly ISO 2, ACFoam
III, ISO95+GL, H-Shield,
Poly ISO 1, ENRGY 3,
Polytherm or Multi-
Max FA3,
Hot
asphalt
Min. 0.25-inch Dens Deck,
Dens Deck Prime, SECUROCK
Gypsum-Fiber Roof Board
Hot
asphalt
SBS-SA,
APP-TA
(Optional) SBS-
SA, APP-TA
SBS-SA,
APP-SA,
APP-TA
-30.0*
CWF-4
Min. 2.5-inch
Tectum Plank
or Tectum LS
Plank
Nail Base,
Polyglass G2
Base
Trufast
Twin Loc-
Nail
9-inch o.c. in 4-inch
lap and 18-inch o.c.
in two, equally
spaced, staggered
center rows
Min. 1.5-inch ACFoam
II, Poly ISO 2, ACFoam
III, ISO95+GL, H-Shield,
Poly ISO 1, ENRGY 3,
Polytherm or Multi-
Max FA3,
Hot
asphalt
Min. 0.25-inch Dens Deck,
Dens Deck Prime, SECUROCK
Gypsum-Fiber Roof Board
Hot
asphalt
SBS-SA,
APP-TA
(Optional) SBS-
SA, APP-TA
SBS-SA,
APP-SA,
APP-TA
-45.0*
TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Roof Cover (Note 15) MDP (psf) Base Fasten Attach Base Ply Cap
CWF-5
Min. 2.5-inch Tectum
Plank or Tectum LS
Plank
Nail Base, Polyglass G2 Base Trufast Inuldek Loc-Nail 9-inch o.c. in 4-inch lap and 12-inch o.c. in two,
equally spaced, staggered center rows (Optional) APP-TA APP-TA -30.0*
CWF-6
Min. 2.5-inch Tectum
Plank or Tectum LS
Plank
Nail Base, Polyglass G2 Base Trufast Twin Loc-Nails 9-inch o.c. in 4-inch lap and 18-inch o.c. in two,
equally spaced, staggered center rows (Optional) APP-TA APP-TA -45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017
Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 20 of 22
TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap
G-1 Existing, sound poured
gypsum or gypsum plank deck
Min. 1.5-inch ACFoam II, Poly
ISO 2, ENRGY 3, H-Shield, Poly
ISO 1 or min. 2.0 pcf, ASTM
C578 expanded polystyrene
OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -72.5
G-2 Existing, sound poured
gypsum or gypsum plank deck
Min. 1.5-inch min. 2.0 pcf,
ASTM C578 expanded
polystyrene
OB500 (Optional) additional layers(s) of base
insulation OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -112.5
G-3 Existing, sound poured
gypsum or gypsum plank deck
Min. 1.5-inch ACFoam II, Poly
ISO 2, ENRGY 3 or H-Shield,
Poly ISO 1
OB500 (Optional) additional layers(s) of base
insulation OB500 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -112.5
G-4 Existing, sound poured
gypsum or gypsum plank deck
Min. 1.5-inch ACFoam II, Poly
ISO 2, ENRGY 3 or H-Shield,
Poly ISO 1 or min. 2.0 pcf,
ASTM C578 expanded
polystyrene
OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board OB500 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -112.5
G-5 Existing, sound poured
gypsum or gypsum plank deck
Min. 1.5-inch ACFoam II, Poly
ISO 2, ENRGY 3, H-Shield, Poly
ISO 1 or Multi-Max FA3
M-OSFA Min. 0.25-inch Dens Deck Prime M-OSFA SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -72.5
G-6 Existing, sound poured
gypsum or gypsum plank deck
Min. 1.5-inch ACFoam II, Poly
ISO 2, ENRGY 3, H-Shield, Poly
ISO 1 or Multi-Max FA3
M-OSFA
(Optional) additional layers(s) of base
insulation and/or min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
M-OSFA SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -202.5
G-7 Existing, sound poured
gypsum or gypsum plank deck
Min. 1.5-inch, min. 2.0 pcf EPS
insulation board, ACFoam II,
ACFoam III, ENRGY 3, H-Shield,
Poly ISO 1, H-Shield CG or
Multi-Max FA3
CR-20 Min. 0.25-inch Dens Deck Prime CR-20 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -72.5
G-8 Existing, sound poured
gypsum or gypsum plank deck
Min. 1.5-inch, min. 2.0 pcf EPS
insulation board CR-20 (Optional) additional layers of base
insulation CR-20 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -240.0
G-9 Existing, sound poured
gypsum or gypsum plank deck
Min. 1.5-inch, min. 2.0 pcf EPS
insulation board CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board CR-20 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -240.0
G-10 Existing, sound poured
gypsum or gypsum plank deck
Min. 1.5-inch ACFoam II, Poly
ISO 2, ACFoam III, ENRGY 3, H-
Shield, Poly ISO 1, H-Shield CG
or Multi-Max FA3
CR-20
(Optional) additional layers(s) of base
insulation and/or min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
CR-20 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA,
APP-TA -257.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017
Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 21 of 22
TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Roof Cover (Note 15) MDP (psf) Base Fasten Attach Base Ply Cap
G-11 Existing sound poured gypsum
or gypsum plank deck Nail Base, Polyglass G2 Base Trufast FM-75 or FM-90
or Twin Loc-Nails
9-inch o.c. in 4-inch lap and 18-inch o.c. in
two, equally spaced, staggered center rows (Optional) APP-TA APP-TA -45.0*
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Substrate
(Notes 1 & 11)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap
SELF-ADHERING BASE PLY:
R-1 Existing
asphaltic roof Min. 1.5-inch Multi-Max FA3 D-IS
(Optional) additional layers(s) of base
insulation and/or min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
D-IS SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-
SA, APP-TA -67.5
R-2 Existing
asphaltic roof
Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3 or
Multi-Max FA3 or min. 2.0 pcf EPS insulation
board
D-IS Min. 0.25-inch Dens Deck Prime D-IS SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-
SA, APP-TA -72.5
R-3 Existing
asphaltic roof Min. 1.5-inch min. 2.0 pcf EPS insulation board D-IS (Optional) additional layers(s) of base
insulation D-IS SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -90.0
R-4 Existing
asphaltic roof Min. 1.5-inch min. 2.0 pcf EPS insulation board D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board D-IS SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA -90.0
R-5 Existing
asphaltic roof Min. 1.5-inch ACFoam II, Poly ISO 2 or ENRGY 3 D-IS
(Optional) additional layers(s) of base
insulation and/or min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
D-IS SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-
SA, APP-TA -90.0
R-6 Existing
asphaltic roof
Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3, H-
Shield, Poly ISO 1 or min. 2.0 pcf EPS insulation
board
OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-
SA, APP-TA -72.5
R-7 Existing
asphaltic roof Min. 1.5-inch, min. 2.0 pcf EPS insulation board OB500 (Optional) additional layers of base insulation OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -120.0
R-8 Existing
asphaltic roof Min. 1.5-inch, min. 2.0 pcf EPS insulation board OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board OB500 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-
SA, APP-TA -120.0
R-9 Existing
asphaltic roof
Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3 or
H-Shield, Poly ISO 1 OB500
(Optional) additional layers(s) of base
insulation and/or min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
OB500 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-
SA, APP-TA -127.5
R-10 Existing
asphaltic roof
Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3, H-
Shield, Poly ISO 1 or Multi-Max FA3 M-OSFA Min. 0.25-inch Dens Deck Prime M-OSFA SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-
SA, APP-TA -72.5
R-11 Existing
asphaltic roof
Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3, H-
Shield, Poly ISO 1 or Multi-Max FA3 M-OSFA
(Optional) additional layers(s) of base
insulation and/or min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
M-OSFA SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-
SA, APP-TA -157.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017
Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 22 of 22
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Substrate
(Notes 1 & 11)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap
R-12 Existing
asphaltic roof
Min. 1.5-inch min. 2.0 pcf ASTM C578 expanded
polystyrene, Min. 2-inch ACFoam II, Poly ISO 2,
min. 1.5-inch Ultra-Max or Multi-Max FA-3, min.
1.3-inch ACFoam III or min. 1.0-inch ISO 95+GL,
H-Shield, Poly ISO 1, H-Shield CG or ENRGY 3
CR-20 Min. 0.25-inch Dens Deck Prime CR-20 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-
SA, APP-TA -72.5
R-13 Existing
asphaltic roof
Min. 1.5-inch min. 2.0 pcf ASTM C578 expanded
polystyrene CR-20 (Optional) additional layers(s) of base
insulation CR-20 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -240.0
R-14 Existing
asphaltic roof
Min. 1.5-inch min. 2.0 pcf ASTM C578 expanded
polystyrene CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board CR-20 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-
SA, APP-TA -240.0
R-15 Existing
asphaltic roof
Min. 1.5-inch Ultra-Max or Multi-Max FA-3, min.
1.3-inch ACFoam III or min. 1.0-inch ISO 95+GL,
H-Shield, Poly ISO 1, H-Shield CG or ENRGY 3
CR-20
(Optional) additional layers(s) of base
insulation and/or min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
CR-20 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-
SA, APP-TA -240.0
R-16 Existing
asphaltic roof
Min. 2-inch ACFoam II, Poly ISO 2, ENRGY-3 or H-
Shield, Poly ISO 1 CR-20
(Optional) additional layers(s) of base
insulation and/or min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
CR-20 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-
SA, APP-TA -247.5
TORCH-APPLIED BASE PLY:
R-17 Existing
asphaltic roof Min. 1.5-inch Multi-Max FA3 D-IS Min. 0.25-inch Dens Deck, Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board D-IS APP-TA (Optional) APP-TA APP-TA -67.5
R-18 Existing
asphaltic roof
Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3 or
min. 2.0 pcf EPS insulation board D-IS Min. 0.25-inch Dens Deck, Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board D-IS APP-TA (Optional) APP-TA APP-TA -90.0
R-19 Existing
asphaltic roof
Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3, H-
Shield, Poly ISO 1 or ISO 95+GL OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board OB500 APP-TA (Optional) APP-TA APP-TA -127.5
R-20 Existing
asphaltic roof
Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3, H-
Shield, Poly ISO 1 or Multi-Max FA3 M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board M-OSFA APP-TA (Optional) APP-TA APP-TA -157.5
R-21 Existing
asphaltic roof
Min. 1.5-inch Ultra-Max or Multi-Max FA-3, min.
1.3-inch ACFoam III or min. 1.0-inch ISO 95+GL,
H-Shield, Poly ISO 1, H-Shield CG or ENRGY 3 or
min. 2.0 pcf ASTM C578 expanded polystyrene
CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board CR-20 APP-TA (Optional) APP-TA APP-TA -232.5