Loading...
HomeMy WebLinkAboutAnchor Bolt Summary' /p 6 d S r QZ-Q --- ANCHOR - - - BOLT SUMMARY ---------------------------- TOTAL ONT LDC DIA. PROD LENGTH BEND (IN) (IN) (IN) (IN) 1 30'-0" STEEL LINE TO STEEL LINE 2 --- --- e DJ --- --- ------ ----- 5/8 .RED HEADS >� 0 8 EW 3/4 2.00 14.0 3.00 SHADED PORTION OF EXIST'G SLAB 28'-0" 1 , -0 0 16 RF ----------------------------------------- 3/4 2.50 20.0 3.00 TO BE CUT OFF AND DISCARDED (TYP. AT BOTH SIDEWALLS) FIELD LOCATED 77 ! 9 -01, 2'-0' 91-0' B 1 I`3F F o o B1 a ZD lir -1 I e_„ 1 LF-1 F-2 EXIST'G 20'-0 X 80'-0" LG '_6'� I F o I CONC. SLAB. 60'-0' TO REMAIN / G I N N m Im =RECEVEDn LLI I C' C_ v J / / I FY W / U /Z I' I r OF / O -1 W //Co I I O O I z / 0 I im m I J / /X 2 FW- / W I C .'. ---_M....__..__�.......,._. �....._. �.._____ CUT OUT EXISTING SLAB o / / C m AND POUR NEW FOOTING. HAIRPIN B kS- z 5'-0' L __-_ RS NG EGS . __ __ � _ _ _`O __. O ..__ ._ (TYP. 8 S.V E.V. F-1 I F o N 0 N F-2r f B I � T 0 , �; � NEW 4' CONC .I G B 1 / / F -0' NEW 4' CONC. Q z O SEAL BLOCK WALL o 9'-0' 12'-0' 9'-0' BLOCK WALL F Z-Zzljzl-zlz-A00 U 20 EMAG SLAB I NEW SLAB 2 FOUNDATION LAYOUT PLAN //��' REVISI❑NS DRAWING STATUS CX] FOR CONSTRUCTION BUCK STEEL, INC ENVI❑RMENTA - -DEVELOPMENT -REV. --DESCRIPTIONS DATE DTLR DATE CHKR APPD C ]FOR- PERMIT ONLY PROJECT 60.0' x.30.0_ x 22.01 -FOUNDATIIIN LAYOUT_ PLAN _ C ] FOR APPROVAL ID 5735 C 3 OTHER, EXPLAIN PROJECT 201 Campbell Rd --- --------------- ADDRESS Fart Pierce, Ft 34945 #' 4 BARS @ 32' C/C 8' CONC. BLOCK WALL W/ ALTERNATE CELLS FILLED - # 3 TIES @ 24' 1'-01—' MIN TYR # 4 BARS @ 32' C/C — 8' C❑NC. BLOCK WALL W/ ALTERNATE CELLS. FILLED ANCHOR BOLT— # 3 TIES @ 24' C/C- (2) # 7 REBARS CUNT. 6':X6.'-6/6 WELDED WIRE MESH 6 MIL POLLY MOISTURE BARRIER 4' THICK SAND LAYER iCTED SOIL 2 - - # 6 BARS CONTINOUS SECT, B—B NOT TO SCALE SAW CUT 1/8' X 1 1/2' CONCRETE -SLAB SECT. C-C ( Const. Joint ) NOT TO SCALE HAIRPIN - BAR W/ 90 °HOOK # 5 W/ 5'-0' LONG LEGS 2-#7BARS CONTINOUS 1' 1' # 6 BARS 10' ❑/ BOTH WAYS TOP i BUTT. OTING-. SIZE SEE FOFOUNDATION PLAN SECT, F—F NOT TO SCALE 6'X6'-6/6 WELDED WIRE MESH 6 MIL POLLY MOISTURE BARRIER 4' THICK SAND LAYER :CTED SOIL 19(s-oozy # 4 BARS X 3'-0' LG. 1/2' xl' JT & 6' HOOK @ 32' C/C FILLED W/ ASPHALT COMPOUND 6' SLAB 4' THICK SAND LAYER (2) # 4 6 MILL RE -BARS POLY. CONT. SECT, B2-B2 NOT TO SCALE JAMB FINISHED FLOOR DEPTH L ELEV. 1 1/2' t F.O. WIDTH t 1 1/2' o a o a O -1O TYP. O.H. DOOR RECESS DETAIL SECT, B1—B1 NOT TO SCALE # 4 BARS @ 32' C/C _ 8' CONC. BLOCK WALL SIDEWALL W/ ALTERNATE CELLS COLUMN MAKE FOOTING FILLED FLUSH WITH TOP �-- A.B. OF EXIST'G SLAB - - a v :e �: EXISTING a _ _ CONCRETE ° SLAB 0i c d 4 ----GENERAL--FOUNDATI❑N--N❑TES- - - -- - - - -- - - -- - - a� .. BOTH w- BARS 8 _ <7) #7 _ EAR - @ ._ ' . C/C- _..._._ . C AYS, T❑P & BOTTOM 1. ALL REINFORCING STEEL SHALL BE GRADE 60 13. PROOF ROLL OF 5' ❑UTSIDE BUILDING F❑❑TPRINT 1'-0' 3'-6' DEFORMED BARS, WITH VIBRATORY COMPACTOR, 2. ALL POURED .IN PLACE SHALL BE F'c 14. FILL TO WITHIN 4' OF FINISHED FLOOR ELEVATI❑N 4'-6' 3000 PSI MIN @ 28 DAYS. WITH CLEAN SAND FILL. 3. WELDED WIRE MESH SHALL MEET ASTM A-185. 15. COMPACT TOP 6' OF FILL MATERIAL TO 95% OF 4. FOUNDATION AND FOOTING SI,ZING BASED ON MODIFIED PROCTOR DENSITY. (MIN) ASSUMED SOIL- - BEARING CAPACITY❑F 2500 PSF. 16, SAW' INDICATED CRACK CONTROL JOINTS WITHIN 5. THE UPPER -12' OF BEARING S❑IL IN F❑❑TING SHALL _ 8 HOURS OF PLACEMENT OF CONCRETE. BE COMPACTED TO.95% OF THE. STANDARD PROCTOR. 17. SDIL`IN FO❑TING TRENCHES SHALL BE FREE OF 6. MIN, REINFORCING STEEL COVER AT EARTH : 3' ORGANIC MATERIAL. ❑R CLAY: IF EITHER IS 7. SLUMP RANGE AT POINT OF DISCHARGE: 3'.-6' ENCOUNTERED IN 'TRENCHES, REMOVE IT .&- 8. OVERLAP ALL WWF A MINIMUM OF 8'. .FOOTING`. REPLACE WITH COMPACTED,, SAND; 9. LAP ALL REINF❑RCING STEEL A MINIMUM OF 48 DIAMETERS. 18. CONTRACTOR TO REVIEW FOUNDATION DRAWINGS 10. REMOVE TOPSOIL & ORGANIC MATERIAL FROM TOP 12' AND CHECK FOR COMPLIANCE WITH ERECTION DRAWINGS OF EXISTING GRADE. BEFORE COMENCMENT ❑F CONSTRUCTI❑N, 11. FDN, IS DESIGNED TO MEET THE 2017 ED. OF THE FBC ANY DISCREPANCY SHOULD; BE BROUGHT TO ENGINEER`S CODE. (IBC 15) W.S. IS 160 MPH, EXP. B ATTENTION: 12. BOTT. OF FTG. MUST BE A MIN. OF 12' BELOW FIN. GRADE 19, TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMICIDES OR OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED FOR USE AS A PREVENTITIVE TREATMENT'TO NEW CONSTRUCTION.. twilPillitlim CX3 FOR CONSTRUCTION C 3 FOR -PERMIT -ONLY 13 FOR APPROVAL 13 OTHER, EXPLAIN x 201 Campbell Rd. Fort P:erce, FL 34945 SECT. G—G NOT TO SCALE CHARLES EMBDEN P.E. 26 HARRIS CIRCLE UXBRIDGE, MA 01569 NORTH CAR❑LINA PE # 22928 PHONE # (508) 826-8772-. SEAL ;VEL❑PMENT Ile CHECK,. FNDWG-2