Loading...
HomeMy WebLinkAboutAPPROVED,Product Approval Underlayment, i 1 '41 BCIS Home I Log In I User Registration Hot Topics I Submit Surcharge I Stats & Facts I Publications I ContactlUsI BCIS Site Map I Links I Search FI rida Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL16048-R6 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Tri-Built Materials Group, LLC Address/Phone/Email PO Box 70 Rutherford, NJ 07070 (800)516-1485 david.ruiz@tribuiltmg.com Authorized Signature David Ruiz david.ruiz@tribuiltmg.com Technical Representative David Ruiz Address/Phone/Email 250 Route 17 North East Rutherford, NJ 07073 (201)842-2449 david.ruiz@tribuiltmaterlaisgroup.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 06/29/2023 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Certificate of Independence Referenced Standard and Year (of Standard) Standard ASTM D1970 ASTM G155 FM 4474 FRSA/TRI April 2012 (04-12) UL 1897 Year 2015 2005 2011 2012 2012 Equivalence of Product Standards Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/25/2017 Date Validated 10/01/2017 Date Pending FBC Approval 10/03/2017 Date Approved 12/12/2017 Summary of Products i, FL # Model, Number or Name Description III 16048.1 TRI-BUILT Roof Underlayments Self -adhering, modified bitumen roof underlayments Limits of Use Installation Instructions jl Approved for use in HVHZ: No . FL16048 R6 II 2017 09 FI AL ER TRI- Approved for use outside HVHZ: Yes BUILT UNDERLAYMENTS FLi6048-R6.pdf Impact Resistant: N/A Verified By: Robert Nieminen, PE-59166 Design Pressure: +N/A/-150 Created by Independent Third Party: Yes Other: 1.) The design pressure noted herein pertains to use of Evaluation Reports foam -on tile systems overtop the self -adhering underlayment FL16048 R6 AE 2017 09 FINAL ER TRI- for one particular application. See ER Section 5.6.4 for details. BUILT UNDERLAYMENTS FL16048-116.pdf 2.) Refer to ER Section 5 for other Limits of Use. Created by Independent Thi"rd� Party: Yes FBack Wext Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1& 1 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: AccesslI Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a pi mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 85( Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with a provided may be used for official communication with the licensee. However email addresses are public record. If you do r provide the Department with an email address which can be made available to the public. To determine if you are a license Product Approval Accepts: r r- Credit Card Safe y Statement :: Refund Statement c-records request, do not send electronic 37.1395. *Pursuant to Section 455.275(1), :mail address if they have one. The emails wish to supply a personal address, please ender Chapter 455, F.S., please click here . EXTERIOR RESEARCH & DESIGN, I.I.C. _ Certificate of Authorization #9503 TRINITYERD 353 CHRISTIAOXFORD,�,N STREET�CT 6478 (203)262-9245 EVALUATION REPORT TRI-BUILT Materials Group, LLC PO Box 70 Rutherford, NJ 07070 (800)516-1485 Evaluation Re Date of SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations construction materials in the State of Florida. The documentation submitted has been reviewe( P.E. for use of the product under the Florida Building Code and Florida Building Code, Resi products described herein have been evaluated for compliance with the 6th Edition (2017) 1 sections noted herein. DESCRIPTION: TRI-BUILT Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Ass herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) cl Quality Assurance documentation changes, or provisions of the Code that relate to the product c this Evaluation Report by the named client constitutes agreement to notify Robert Niemine changes or the referenced Quality Assurance documentation changes. Trinity ERD requires a cc Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done ii INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user b its distributors and shall be available for inspection at the job site at the request of the Building ( This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing w P.E. on 09/25/2017. This does document. CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any cc distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it i 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing of which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in th product. 5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the D, project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design specifically for that purpose. A42960.10.12-116 FL16048-R6 ance: 10/25/2012 )n 6: 09/25/2017 erning the use of Robert Nieminen, tial Volume. The da Building Code rice Agency noted Iges, the referenced nge. Acceptance of P.E. if the product olete review of this iay be displayed in s entirety. he manufacturer or cial. zed by Robert Nieminen, as an electronically signed i manufacturing or tes. buting products for oval process of the r of Record for any nce unless retained ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT N demonstrated compliance with the following sections of the 6th Edition (2017) Florida Bui in accordance with the following Standards. Compliance is subject to the Installation RegL Conditions of Use set forth herein. 2. STANDARDS: Section 1504.3.1 1504.3.1 1504.6 1507.2.4 / 1507.1.1, 1507.2.9.2 1507.3.3 3. REFERENCES: Enti ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD(TST6049) ERD (TST6049) ERD (TST6049) ERD(TST6049) ERD(TST6049) ERD (TST6049) ERD(TST6049) ERD(TST6049) ERD (TST6049) ERD(TST6049) UL, LLC. (QUA9625) UL, LLC. (QUA9625) 4. PRODUCT DESCRIPTION: Property Wind Resistance Wind Uplift Accelerated Weathering Physical Properties Physical Properties Examination Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Accelerated Weathering Wind Resistance Quality Control Quality Control Standard FM 4474 UL 1897 ASTM G155 ASTM D1970 FRSA/TRI April 2012 (04-12) Reference S40540.02.13-1 S40540.11.13 S40540.03.14 S44870.04.14-2 S44870.04.14-3 S44870.04.14-1 S44870.04.14-4 S43530.02.14-1-R1 S43530.05.14 S40540.10.14 SC7645.02.15 SC8520.04.15 SC14045.05.17-R1 Multiple -Listing R16814 Service Confirmation 4.1 Tri-Built Sand-R SA Shingle Underlayment is a self -adhering, glass -mat reinforc modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D1S 4.2 Tri-Built S/A HT TU Underlayment is a self -adhering, non -woven polyester fabric bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012. 4.3 Tri-Built Smooth HT S/A Underlayment is a self -adhering, glass -mat reinforl modified bitumen roof underlayment; meets ASTM D1970. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P. Designer of Record for any project on which this Evaluation Report, or previous used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Apprc Directory for fire ratings of this product. Exterior Research and Design, LLC. Certificate of Authorization #9503 GP EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Roof Underlayments; (800) 516-1485 ERD Group, LLC, have ie through testing ;and Limitations / Year 2011 2012 2005 2015 2012 Date 02/19/2013 11/19/2013 03/26/2014 04/02/2014 04/02/2014 04/10/2014 04/10/2014 05/14/2014 05/28/2014 10/31/2014 02/13/2015 05/27/2015 06/07/2017 12/10/2015 Exp.07/18/2020 sand -surfaced, SBS SBS modified film -surfaced, SBS re, in any way, the ons thereof, is/was Roofing Materials 2eport A42960.10.12-R6 FL16048-R6 Revision 6: 09/25/2017 Page 2 of 6 - T INITY ERD 5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover WY ere the product is specifically referenced within FBC approval documents. If not listed, a request II ay be made to the Authority Having Jurisdiction for approval based on this evaluation combined with suipporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE 1 ,RooF CoaORnols . 9.. _. ood Underlayment h Asphalt Nail-On Tile Foam -On Tile Metal W& Sh Shakes Slate ingles ngles Tri-Built Sand-R SA Shingle Yes No No No eas YYes Underlayment Tri-Built S/A HT TU Yes Yes Yes Yes Yes Yes Underlayment See 5.5.1 Tri-Built Smooth HT S/A Yes No No Yes Yes Yes Underlayment I I 5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. TABLE 1A. Au owaBLETiLE ADHESIVE / UNDERLpYMENT COMBINATIONS) .." . . _L _. _ .. _ ; . Adhesive Florida Product Approval Underla menu Y ICP Adhesives Polyset® AH-160 FL6332 Tri-Built S/A HT TU Underlayment Dow TileBoncl ' FL22525 Tri-Built S/A HT TU Underlayment 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete. While not required over plywood, OSB or Southern Yellow Pine substrates, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT Materials Group, LLC requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering underlayment. 5.6.2 Bond -to -Insulation: Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation ;shall be attached per minimum requirements of the prepared roof covering manufacturer's Product App )oval. For installations under foam -on tile systems (Tri-Built S/A HT TU Underlayment only), insulation ttachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix D or TAS 114, Appendix J. �I 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. Exterior Research and Design, U.C. Evaluation Report A42960.10.12-1116 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION I FL16048-R6 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 3 of 6 T INITY ERD 5.6.3 Bond to Mechanically Attached Base Laver: Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ ASTM D226, Type I or II felt. For installations under mechanically attached prepared roof coverings, base layer lihall be attached per minimum codified requirements. For installations under foam -on tile systems ( ri-Built S/A HT TU a Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04- 12). N 5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam ion the systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are, used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind loads are, based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind pressures. 1I II #1 Maximum Design Pressure = -45.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 or RESISTO EXTERIOR PRIMER Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered. #2 Maximum Design Pressure = -67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Soprema Elastocol 600c Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered. #3 Maximum Design Pressure = -150.0 psf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-si, requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and d adhesion. All sheathing fasteners shall be driven flush with splinters and wood projections shall be removed/sanded. Primer: (Optional) RESISTO EXTERIOR PRIMER Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered, shall be thoi roller and/or weighted roller to ensure there are no voids, ar voids/bridging at side and end -laps. #4 Maximum Design Pressure = -60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to & Having Jurisdiction. Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached ti and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps equally spaced rows in the center of the sheet. Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered. Exterior Research and Design, LLC. Certificate of Autharization #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Roof Underlayments; (800) 516-1485 p) to meet project ; that may inhibit surface. All sharp roll using hand re there are no of Authority nails (FBC 1517.5.1) 6-inch o.c. in three, FL16048-R6 Revision 6: 09/25/2017 Page 4 of 6 '�. TRINITYERD 5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 ariud 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDl, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3]gIphancements. 5.7 Exposure Limitations: Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left exposed for longer than 30-days after installation Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days, after installation. 5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)1: When loading roof tiles on the underlayment in direct -deck tile assemblies, the maxi � lum roof slope shall be as follows. These slope limitations can only be exceeded by using battens duringIII loading of the roof tiles. Underlayment Tri-Built S/A HT TU Underlayment Tile Profile I Staging Method Flat Max.10-tile stack egged Max.10-tile stack Max. 10-tile stack (bottom 2-t shall be inverted, followed by 8 on slope, as shown belo Lugged Exterior Research and Design,LLC. Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Roof Underlayments; (800) 516-1485 Maximum Slope 6:12 5:12 tack high 6:12 Evaluation (Report A42960.10.12-R6 FL16048-R6 Revision 6: 09/25/2017 Page 5 of 6 i TRINITY ERD 6. INSTALLATION: 6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly 111 to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Tri-Built Sand-R SA Shinkrle Underlayment, Tri-Built S/A HT TU Underlayment or Trli (Built Smooth HT S/A Underlayment: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.3.2 Non -Tile applications: While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel -off the release film diagonally while holding the membrane tight. Firmly roll, broom or hand -press the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertic'all seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with TRI-BUILT Materials Group, LLC requirements. When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back -nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys, apply the sheet starting at the lowest point and work upward. I ' I 6.3.3 Tile Applications (Tri-Built S/A HT TU Underlayment only): Reference is made to FRSA/TRI April 2012 (04-12) 4nstallation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012 (04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile staging. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. S. MANUFACTURING PLANTS: Gulfport, MS 9. QUALITY ASSURANCE ENTITY: UL, LLC —QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 6 of 6