HomeMy WebLinkAboutField Density Tests of Compacted SoilsFEDERAL R EG ENGINEERING & TESTING 1798 AGORA CIRCLE S.E. SUITE 5 250 S.W. 13TH AVENUE PALM BAY, FLORIDA 32909 MAR 3 12008 POMPANO BEACH, FLORIDA 33069 FIELD DENSITY ',qVIPACTED SOILS DATE: 2/22/08 ORDER NO: 08-664 PERMIT NO.O1OZ — O 1 (9 3 CLIENT: HERITAGE CONTRACTING SERVICES ADDRESS: 1945 22ND AVENUE, VERO BEACH, FLORIDA 32960 PROJECT: PROPOSED RESIDENCE BUILDING PAD ADDRESS: 21220 GLADES CUT OFF ROAD, PORT ST. LUCIE, FLORIDA MATERIAL DESCRIPTION: BROWN SILICA SAND W/TRACES OF CLAY & SHELL FRAGS LOCATION: NE CORNER OF PAD LOCATION: NW CORNER OF PAD LOCATION: SW CORNER OF PAD LOCATION: LOCATION: LOCA FIELD DENSITY METHOD A.S.T.M. D-2922 DRY DENSITY P.C.F. IN THE FIELD 106.1 ' 106.5 106.9 % MOISTURE 9.8 10.0 10.6 % COMPACTION IN THE FIELD 97.2 97.6 97.9 % COMPACTION REQUIREMENT 95% PROCTOR VALUE, P.C.F. 109.2 OPTIMUM MOISTURE, % 12.8 LABORATORY NO. P-337 DEPTH ININCHES 12 PROCTOR A.S.T.M D-1557 METHOD REMARKS: SOIL NOT TESTED BELOW FOOTERS TESTED BY: RD Respectfully submitted, CHECKED BY: KM �N. , � As a mutual protection to clients, the public and ourselves, all reports FEDERAL ENGINEERING & STING are submitted as the confidential property of clients, and authorization FLORIDA REG. #39534 for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. A density test determines the degree of compaction of the tested layer of material only. A density does not replace a soil bearing capacity determination.