Loading...
HomeMy WebLinkAboutCooling Load5/N 930 RIGHT--N ZONE SUMMARY 01/10/96 Four: DRAWDY BROS CONSTRUCTION By: 0 Job #: WAREHOUSE EDWARDS RD ZONE: one C O O L I N G L 0 A D 1. DESIGN CONDITIONS at 3PM Peak .load at 3PM Inside: 75 F Outside: 90 F TD: 15 deg F RHH: 50 p Grains: 62 Mult: 1.0 Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 870 3. TRANSMISSION GAINS Sensible 2096 - Walls: 26 - -- Glass: 468 -- - ;' Doors: 468 - - Partitions: 385 - - Floors: 0 - - Roofs/Ceilings: 150 - - Return Air Ceiling: 600 - - 4. INTERNAL HEAT GAIN Sensible Latent 6223 3000 r Occupants: 3000 3000 -- - Lights: 623 0 - - Motors: 0 0 - - Appliances & Other: 2600 0 - - 5. INFILTRATION: Outside air CFM: 37 605 1546 6. SUBTOTAL: Space load 9795 4546 7. SUPPLY DUCT 294 - 8. SUBTOTAL: Bldg comp"s and supply duct 10089 - Actual CFM: 459 at Supply TD: 20 - - 9. VENTILATION: Make --up air CFM: 0 0 0 10. RETURN AIR LOAD: Lighting & roof (net) --600 -- 11. RETURN DUCT 0 - 12. TOTAL LOADS ON EQUIPMENT 9489 4546 H E A T I N G L 0 A D 13. DESIGN CONDITIONS Mult: 1.0 Inside: 70 F Outside: 42 F TD: 28 deg F 14. TRANSMISSION LOSSES 3610 Walls: 20 - Glass: 924 - Doors: 874 - Partitions: 719 - Floors: 794 -- Roofs/Ceilings: 280 - Return Air Roof: 0 - 15. INFILTRATION: Outside air CFM: 55 1694 16. SUBTOTAL: Building components 5304 17. SUPPLY DUCT 424 18. VENTILATION: Make-up air CFM: 0 0 19. HUMIDIFICATION 299 20. RETURN DUCT 0 21. TOTAL HEATING LOAD ON EQUIPMENT 6026 MQN114.1 N: ALt•h rrl PTAHT-N: `!1 _1S