Loading...
HomeMy WebLinkAboutStructural Design CalculationsGULF -STATES MANUFACTURERS, INC. RIGID FRAME STRUCTURAL DESIGN CALCULATIONS *JOB30123-0; BLDGOI; FRM01; DTLOO; DES REV00; REV DATE10/23/'95; REV TIME0751.* COMMENT TOP=LEFT COLUMN LINES:2,3,4,8,9,10,11 SYMMETRY FORCED D I M E N S I 0 N S ] L 0 A D I N G D A T A ]' GIRT DEPTH BUILDING WIDTH 70.00 FEET ] ] DEAD LOAD- 2.0 LBS/SQ ] FT J "BAY SPACING 25.00 FEET ] LIVE LOAD 12.0 LBS/SQ FT J ] SNOW LOAD 0.0 LBS/SQ FT J LEFT SIDE RIGHT SIDE ] WIND LOAD 26.8 LBS/SQ FT J ROOF PLANE WIDTH '.COLUMN 35.00 35.00 FEET J AUXI LOAD- 0.0 LBS/SQ FT J ELEVATION 0.00 0.00 FEET ] J EAVE HEIGHT 20.00 20.00 FEET ] J ROOF SLOPE 1.00 1.00 • /12.0 J ] COLUMN OFFSET 8.00 8.00 INCHES ] J RAFTER OFFSET ..:' 8.00 ---------------------------------------------------------------------------- 8.00 INCHES J J 8.00 8 S. E G M E N T D A T A *JOB30123-0; BLDG01; FRM01; DTL00; DES REV00; REV DATE10/23/95; REV TIME0751.* NOMINAL YOUNG'S YIELD COLUMN OUTER OUTER INNER INNER , END CONDITION WEB HEIGHTS MODULUS POINT /RAFTR FLANGE FLANGE WEB FLANGE FLANGE ANALYSIS SEGMENT SEGMENT NEAR FAR NEAR FAR NEAR FAR E FY OFFSET WIDTH THICK. THICK. WIDTH THICK. LENGTH NUMBER TYPE JOINT JOINT JOINT JOINT (IN) (IN) (KSI) (KSI) (IN) (IN) (IN) (IN) (IN) (IN) (FEET) LRFC 1 VARI 1 2 PIN FIX 6.50 27.75 29000.0 50.00 8.00 6.00 0.3125 ,0.1350 6.00 0.3125 18.32 LRFR 1 VARI 2 5 FIX FIX 27.75 9.75.29000.0 50.00• 8.00 5.00 0.3125 '0.1500 5.00 0.3125 14.37 LRFR 2 VARI 5 6 FIX FIX 9.75 27.75 29000.0 50.00 8..00 5.00 0.2500 0.1200 5.00 0.2500 18.93 RRFR 1 VARI 6 7 FIX FIX 27.75 9.75 29000.0 50.00' B.00 5.00 0.2500 0.1200 5.00 0.2500 18.93 :RRFR 2 VARI 7 3 FIX FIX 9.75 27.75 29000.0 50.00 8.00 5.00 0.3125 0.1500 5.00 0.3125 14.37 RRFC 1 VARI 3 4 FIX PIN 27.75 6.50 29000.0 50.00 8.00 6.010 0.3125 0.1350 6.00 0.3125 18.32 P U R L I N, G I R T A N D J O I S T L 0 A D 'P 0 I N T S ** LRFC 0.000OL 4.000OL 7.2917 12.5000* 17.5000L 20.000OL ``LRFR 0.00OOL 2.4531 4.9618* 9.9791* 14.9964* 20.0138* 25.0311* 30.0484* 34.0623* RRFR 1.0590* 5,0729* 10.0902* 15.10751 20.1249* 25.1422* 30.1595* 35.1213 RRFC 0.000OL 2.5000L 7.5000* 12.7083 16.000OL 20.000OL *.:-.FLANGE BRACE AT THIS LOCATION ** LOCATIONS ARE GIVEN AS DISTANCES ALONG THE REFERENCE LINE FROM THE LINE PART ORIGIN. TOTAL WEIGHT OF ONE FRAME ' e 0 3UILDING WIDTH 70.00; BAY SPACING 25.00; EAVE HEIGHT 20.00; ROOF SLOPE 1.00; DEAD LOAD 2 PSF; LIVE LOAD 12 PSF; WIND LOAD 26 PSF F R A M E D I A G R A M LRFR _ RRF,R ----------- ----------------- ---------------- 5-- ---- 7 ------------------ 2/'; ] :l ] ] l ] L ] „ R ] R F ] R ] ] F ] c : ]. C ] ] ] ] � l A 4/ A A ................. ]............... ]................ I ................ ]. .3................I. .l 0 10 20 , 30 40............. 50 60.............. 70 ONE INCH = 6.00 FEET C L E A R A N C E S LEFT END RIGHT END MINIMUM VERTICAL VERTICAL VERTICAL HORIZONTAL LEFT RIGID FRAME RAFTER 17.21 19.88 17.21 63.94 RIGHT RIGID FRAME RAFTER 19.88 17.21 .17.21 63.94 21 •w REACT I O N S F O R I E L E,M-ErN T•AVR Yy� LAOyA D S REACTIONS AT X= 0.00 70.00 VERT 2.92 2.92 DEAD HORI 1.37 -1.37 MOMN 0. 0. VERT 10.50 10.50 LIVE HORI 5.79 -5.79 MOMN 0. 0. VERT -22.82 -15.87 WINDIL-R HORI -14.71 4.67 MOMN 0. 0. VERT -15.87 -22.82 WINDIR-L HORI -4.67- 14.71 MOMN 0. 0. VERT -13.44 -6.49 WIND2L-R HORI -12.17 2.13 MOMN 0. 0. VERT -6.49 -13.44 WIND2R-L HORI -2.13 12.17 , MOMN 0. 0. VERT -23.45 -23.45 WEND HORI -8.33 8.33 MOMN 0. 0. ° ** THE FRAME WEIGHT WAS ADDED TO THE SPECIFIED DEAD LOAD R E A C T I O N S F O R L 0 A D C O M B I N A T I O N S REACTIONS AT X= 0.00 70.00 VERT 13.42 13.42 D+L HORI 7.16 -7.16 ' MOMN 0. 0. VERT -19.90 -12.95 D+W1(LTOR HORI -13.34 3.30 MOMN 0. 0. VERT -12.95 -19.90 D+W1(RTOL HORI -3.30 13.34 MOMN 0. 0. VERT -10.51 -3.57 D+W2(LTOR HORI -10.80 0.76 MOMN 0. 0. VERT -3.57 -10.51 D+W2(RTOL HORI -0.76 10.80 ` MOMN 0. 0. VERT -20.53 -20.53 D+WEND HORI -6.96 6.96 MOMN 0. 0. "THE FRAME WEIGHT WAS ADDED TO THE SPECIFIED DEAD LOAD CONNECTION 1 AT JOINT 1 2 1.000" DIAM XqPmgglgb LONG ASTM A 36 BOLTS WITH NUTS AND OP HOOKS BASE PLATE IS 0.500 INCHES THICK X 8.0 " WIDE X 8.0000 LONG 1N ZJ ^ .CONNECTION 4 AT JOINT 4 2 1.000" DIAM XlNMVWM LONG ASTM A 36 BOLTS WITH NUTS AND #0 HOOKS BASE PLATE IS 0.500 INCHES THICK X 8.0 " WIDE X 8.0000 LONG * * * WARNING !!! *. A PURLIN MAY CAUSE * * PROBLEMS WITH THE KNEE CONNECTION * * ************************************ c GULF STATES MANUFACTURERS, INC. RIGID FRAME STRUCTURAL DESIGN CALCULATIONS *JOB30123-0; BLDG02; FRMO1; DTL00; DES REV00; REV DATE10/23/95; REV TIME0839.* COMMENT TOP=LEFT=LOW SIDE COLUMN LINES:6 SYMMETRY NOT FORCED • D I M E N S I O N S ] L 0 A D I N G D A T A ] GIRT DEPTH 8.00 8 BUILDING WIDTH 2O.00 FEET ] ] DEAD LOAD 2.0 J LBS/SQ FT ] +BAY SPACING 26.00 FEET ] LIVE LOAD 12.0 LBS/SQ FT ] J SNOW LOAD 0.0 LBS/SQ FT ] LEFT SIDE RIGHT SIDE ] WIND LOAD 26.8 LBS/SQ FT ] ROOF PLANE WIDTH 2O.00 0.00 FEET ] AUXI LOAD 0.0 LBS/SQ FT J COLUMN ELEVATION 0.00 0.00 FEET ] ] EAVE HEIGHT 14.33 16.00 FEET ] J ROOF SLOPE 1.00 -1.00 /12.0 ] J COLUMN OFFSET 8.00 8.00 INCHES ] RAFTER OFFSET 8.00 0.00 INCHES --------------------------------------------------------------------------------- ] J J S E G M E N T'.. D A T A *JOB30123-0; BLDG02; FRM01; DTL00; DES REV00; REV DATE10/23/95; REV TIME0839.* NOMINAL YOUNG'S YIELD COLUMN OUTER OUTER INNER INNER ' SEGMENT SEGMENT END CONDITION NEAR FAR NEAR WEB HEIGHTS MODULUS POINT /RAFTR FLANGE FLANGE WEB FLANGE FLANGE ANALYSIS NUMBER TYPE FAR JOINT JOINT JOINT JOINT NEAR (IN) FAR (IN) E (KSI) FY (KSI) OFFSET WIDTH THICK. THICK. WIDTH THICK. LENGTH LRFC 1 VARI 1 2 PIN FIX 6.50 13.75 29000.0 50.00 (IN) 8.00 (IN) (IN) 6.00 0.1875 (IN) 0.1200 (IN) 6.00 (IN) (FEET) 0.1875 13.18 LRFR 1 PRIS RRFC 1 2 3 FIX FIX 13.75 13.75 29000.0 50.00 8.00 5.00 0.1875 0.1200 5.00 0.1875 17.54 VARI 3 4 FIX PIN 13.75 6.50 29000.0 50.00 8.00 6.00 0.2500 '0.1200 6.00 0.1875 14.64 P U R L I N, G I R T A N D J O I S T L 0 A D P O I N T S ** LRFC O.000OL 14.3333L LRFR O.000OL 2.4531* 4.9618 9.9791 14.9964 17.5051* 20.0138L RRFC O.000OL 16.000OL n ` - FLANGE BRACE AT THIS LOCATION ** LOCATIONS ARE GIVEN AS DISTANCES ALONG THE REFERENCE LINE FROM THE LINE PART ORIGIN. .'OTAL WEIGHT OF ONE FRAME l i' BUILDING WIDTH 2O.00; BAY SPACING 26.00; EAVE HEIGHT 14.33; ROOF SLOPE 1.00; DEAD LOAD 2 PSF; LIVE LOAD 12 PSF; WIND LOAD 26 PSF F R A M E D I A G R A M ' LRFR -- - -- - 3 / -- - -- - -- - -- - ] ) ) ] ) ) ] ] ) ) ) ) ] ) ] ] ) ] ] ] R ] L R } F ] R ] C ] F ] ] C ] ] ) ] ] ] ] ] ] ] ) ] ) ) ) ] ] ) ) 1/ 4/ A A ]................................. ]................................. ] 0 10 20 ONE INCH = 3.00 FEET C L E•A R A N C E S LEFT END RIGHT END MINIMUM VERTICAL VERTICAL VERTICAL HORIZONTAL LEFT RIGID FRAME RAFTER 12.64 14.00 12.64 16.31 R E A C T I O N S F O R E L E M E N T A R Y L 0 A D S A REACTIONS AT X= 0.00 20.00 VERT 0.84 0.88 DEAD HORI 0.09 -0.09 MOMN 0. 0. • VERT 3.12 3.12 LIVE HORI 0.39 -0.39 MOMN 0. 0. VERT -9.69 -4.24 WINDIL-R HORI -3.89 -3.57 MOMN 0. 0. VERT -0.49 -8.57 WINDIR-L HORI 4.79 4.25 MOMN 0. 0. VERT -6.91 -1.46 WINDIL-R HORI -5:54 -1.93 MOMN 0.1 0. VERT 2.30 -5.78 WIND2R-L HORI 3.14 5.89 MOMN 0. 0. ** THE FRAME WEIGHT WAS ADDED TO THE SPECIFIED DEAD LOAD R E A C T I O N S F O R L 0 A D C O M B I N A T I O N S REACTIONS AT X= 0.00 20.00 VERT 3.96 4.00 D+L HORI 0.48 -0.48 MOMN 0. 0. VERT -8.85 -3.36 D+W1(LTOR HORI -3.81 -3.66 MOMN 0. 0. VERT 0.35 -7.69 D+W1(RTOL HORI 4.87 4.16 MOMN 0. 0. VERT -6.07 -0.57 D+W2(LTOR HORI -5.45 -2.01 MOMN . 0. 0. VERT 3.14 -4.90 D+W2(RTOL HORI 3.23 5.81 MOMN 0. 0. ** THE FRAME WEIGHT WAS ADDED TO THE SPECIFIED DEAD LOAD CONNECTION 1 AT JOINT 1 2 0.750" DIAM X1§WPPWPLONG ASTM A 36 BOLTS WITH NUTS AND 00 HOOKS BASE PLATE IS 0.500 INCHES THICK X 8.0 " WIDE X 8.0000 " LONG :ONNECTION 4 AT JOINT 4 2 0.750" DIAM X19WY9"- LONG ASTM A 36 BOLTS WITH NUTS AND W HOOKS BASE PLATE IS 0.500 INCHES THICK X 8.0 " WIDE X 8.00001-" LONG