HomeMy WebLinkAboutRevisionOFFICE USE ONLY:
DATE FILED:
REVISION FEE:
PERMIT # �QO 5 a O'S t q
RECEIPT #
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982.5652
(772) 462-1553
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
LOCATION/SITE%i�►'1
ADDRESS: l 1�09
DETAILED DESCRIPTION OF PROJECT
REVISIONS: „ _
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: A
BUSINESS NAME:
QUALIFIERS NAME: _cuo
ADDRESS:
CITY: r• Q•�i� STA
PHONE (DAYTIME): _ 101=
OWNER/BUILDER INFORMATION:
NAME: C/), S C: G; 0
05lq
ST. LUCIE CO CERT. #:
FAX:
ZIP:
ADDRESS:
CITY: STATE: ZIP:
PHONE (DAAYTIME: FAX:
A.RCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE (DAYTIME):
SLCCC: 9123109
Revised 06130117 REVISION
September 1, 2020
To: SLC Building Dept.
Plan Review
Permit 2005-0519
Revision(s)
Cicio residence
1. Please see 2 attached signed and sealed floor pli ns reflecting 3 window changes per
owner's request. Garage and bedroom #3 changed from 2-SH35's to 1-SH35 at each
area.
2. SH25 in rear game room was deleted per owner's request.
3. Attached are new Energy Code forms to reflect these changes, per Inspectors request.
4. Inspector and Gem Builders cannot find approved AC layout'in the permit pack. We are
confident 2 copies were submitted with original permit package. Attached are 2 more
for approval.
Gem Builders, Inc
CRC036620
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* =100
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location AHU CLST
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 4
13. Cooling system: Capacity
58.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 3187
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.577
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.236
14. Heating system: Capacity
34.0
c) Area
7c. 491.4
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f1 Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.98
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2. 5.0
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131. 13.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and Insulation level
a) Ceiling fans
a) Under attic
11 a. 0.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
f) Programmable thermostat
No
*Label requi y Section R303.1. the Florida
Building Code, Energy Conservation, if not DEFAULT.
f
I certify hat this home has complied with th
lorida Building Code, Energy Conservation, through the above energy
saving
features which will be installed (or
eeded) in this home before final inspection. Othe se, a n w EPL
displa ca wi a completed aced on sta ad code compliant features.
Builde lure:
Date:
Address of New Home: 1807 HAZELWOOD DRIVE
City/FL Zip: FORT PIERCE, FL
8/31/2020 3:08:18 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software
Page 1 of 1
REVISION0,2h
r n
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: CICIO RESIDENCE Builder Name. GEM BUILDERS
Street: 1807 HAZELWOOD DRIVE Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Y
U
Owner. CHRISTOPHER AND SHANA CICIO Jurisdiction: ST LUCIE COUNTY
w
x
Design Location: FL, Fort Pierce
v
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA,
General
A continuous air barrier shall be Installed In the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation In any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided Instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on installation
Narrow cavities
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures Installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring an
J
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that Is recommended by the manufacturer. Caulking or other
J
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and wails or ceilln-cis. -
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
8/31/2020 3:09 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: CICIO RESIDENCE
Builder Name: GEM BUILDERS
Street: 1807 HAZELWOOD DRIVE
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner: CHRISTOPHER AND SHANA CICIO
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(3100.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=5.0 2820.00 112
b. Frame - Wood, Adjacent
R=13.0 280.00 1`12
3. Number of units, if multiple family 1
c. N/A
R= fN
4. Number of Bedrooms 4
d. N/A
R= ft2
10. Ceiling Types (3187.0 sgft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 3187.00 ft
6. Conditioned floor area above grade (1`12) 3187
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
11. Ducts
R= ft2
R ft
7. Windows(491.4 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: AHU CLST
6 250
a. U-Factor: Sgl, U=0.58 248.09 ft2
SHGC: SHGC=0.24
b. U-Factor: Sgl, U=0.65 104.56 ft2
12. Cooling systems
k8Efficiency
SHGC: SHGC=0.21
a. Central Unit
58.0 SEER:16.00
c. U-Factor: Sgl, U=OA5 78.77 ft2
SHGC: SHGC=0.26
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 60.00 ft2
a. Electric Strip Heat
34.0 COPA.00
SHGC: other (see details)
Area Weighted Average Overhang Depth: 7.464 ft.
Area Weighted Average SHGC: 0.236
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (3187.0 sgft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 3187.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Total Proposed Modified Loads: 106.57
PASS
Glass/Floor Area: 0.154
Total Baseline Loads: 106.93
I hereby certify that the plans and specifications covered by
Review of the plans and
F-vBE STgl,
0 -
this calculation are in compliance with the Florida Energy
specifications covered by this
indicates
=
Code.
calculation compliance
"d,,, O
with the Florida Energy Code.
+r
PREPAR
Before construction is completed
DATE -3 -1 2
this building will be inspected for
compliance with Section 553.908
e certify that this b ' d, is in compliance
Florida Statutes,
rl,C
ith t d de.
Od WE
OWNE GENT
-BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certificati n by air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in acc rdance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with;envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
8/31/2020 3:07 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 8
FORM R405-2017
INPUT SUMMAKY GIIEGKLI51 Kt:PUK I
PROJECT
Title:
CICIO RESIDENCE
Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 3187
Lot #
Owner Name:
CHRISTOPHER AND SHANA
Total .Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
GEM BUILDERS
Rotate Angle: 0
Street:
1807 HAZELWOOD DR
Permit Office:
ST LUCIE COUNTY
Cross Ventilation: No
County.
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State,
Zip:
FORT PIERCE,
Family Type:
Single-family
FL ,
New/Fadsting:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
LOW
BLOCKS
Number
Name
Area
Volume
1
Entire House
3187
33630
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
UTILITY RM
120
1200 No
0
1
Yes
Yes
Yes
2
HALLWAY
102
1020 No
0
1
No
Yes
Yes
3
POWDER RM
42
420 No
0
1
Yes
Yes
Yes
4
PANTRY
28
280 No
0
1
No
Yes
Yes
5
M BATH
190
1900 No
0
1
Yes
Yes
Yes
6
M WIC
119
1190 No
0
1
No
Yes
Yes
7
M HALL
35
350 No
0
1
No
Yes
Yes
8
M TOILET
30
300 No
0
1
Yes
Yes
Yes
9
MASTER BEDROO
272
2720 No
0
1
1
Yes
Yes
Yes
10
KITCHEN/DINING
480
4800 Yes
0
1
Yes
Yes
Yes
11
OFFICE
143
1430 No
0
1
Yes
Yes
Yes
12
GREAT ROOM
440
6160 No
0
1
Yes
Yes
Yes
13
FOYER
60
600 No
0
1
Yes
Yes
Yes
14
WIC 2
30
300 No
0
1
No
Yes
Yes
15
BEDROOM 2
168
1680 No
0
1
1
Yes
Yes
Yes
16
BEDROOM 3
165
1650 No
0
1
1
Yes
Yes
Yes
17
HALL 2
69
690 No
0
1
No
Yes
Yes
18
WIC 3
40
400 No
0
1
Yes
Yes
Yes
19
LINEN
12
120 No
0
1
No
Yes
Yes
20
SINKS
36
360 No
0
1
No
Yes
Yes
21
TOILET
36
360 No
0
1
Yes
Yes
Yes
22
BATH 3
78
780 No
0
1
No
Yes
Yes
8/31/2020 3:07 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 8
FORM R405-2017 INPUT SUMMARY GMEGKL15T Kt1'UK I
SPACES
Number
Name Area Volume
Kitchen Occupants
Bedrooms
InfilID Finished
Cooled
Heated
23
WIC 4 30
300
No
0
1 Yes
Yes
Yes
24
HALL 52
520
No
0
1 Yes
Yes
Yes
25
BEDROOM 4 182 1820
No
0
1
1 Yes
Yes
Yes
26
GAME ROOM 216 2160
No
0
1 Yes
Yes
Yes
27
AHU CLST 12
120
No
0
1 No
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulatio
UTILITY RM
10 ft
0
120 ft2
—
1
0
0
2Slab-On-Grade Edge Insulatio
HALLWAY
1 ft
0
102 ftz
—
1
0
0
3 Slab -On -Grade Edge Insulatio
POWDER RM
2 ft
0
42 ft2
—
1
0
0
4 Slab -On -Grade Edge Insulatio
PANTRY
1 ft
0
28 ft2
—
1
0
0
5 Slab -On -Grade Edge Insulatio
M BATH
16 ft
0
190 ft2
—
1
0
0
6 Slab -On -Grade Edge Insulatio
M WIC
1 ft
0
119 ft2
—
1
0
0
7 Slab -On -Grade Edge Insulatio
M HALL
1 ft
0
35 ft2
—
1
0
0
8 Slab -On -Grade Edge Insulatio
M TOILET
6 ft
0
30 ft2
1
0
0
9 Slab -On -Grade Edge Insulatio MASTER BEDRO 39 ft
0
272 ft2
—
1
0
0
10SIab-On-Grade Edge Insulatio
KITCHEN/DININ
25 ft
0
480 ft2
—
1
0
0
11Slab-On-Grade Edge Insulatio
OFFICE
19 It
0
143 ft2
—
1
0
0
12SIab-On-Grade Edge Insulatio
GREAT ROOM
20 ft
0
440 ft2
—
1
0
0
13SIab-On-Grade Edge Insulatio
FOYER
loft
0
60 ft2
—
1
0
0
14SIab-On-Grade Edge Insulatio
WIC 2
1 ft
0
30 ft2
_
1
0
0
15SIab-On-Grade Edge Insulatio
BEDROOM 2
25 ft
0
168 ft2
—
1
0
0
16SIab-On-Grade Edge Insulatio
BEDROOM 3
27 ft
0
165 fie
—
1
0
0
17SIab-On-Grade Edge Insulatio
HALL 2
1 ft
0
69 ft2
—
1
0
0
18SIab-On-Grade Edge Insulatio
WIC 3
5 ft
0
40 ft2
—
1
0
0
19SIab-On-Grade Edge Insulatio
LINEN
1 ft
0
12 ft2
1
0
0
20SIab-On-Grade Edge Insulatio
SINKS
1 ft
0
36 ft2
—
1
0
0
21SIab-On-Grade Edge Insulatio
TOILET
6 ft
0
36 ft2
—
1
0
0
22SIab-On-Grade Edge Insulatio
BATH 3
1 ft
0
78 ft2
—
1
0
0
23SIab-On-Grade Edge Insulatio
WIC 4
6 ft
0
30 ft2
—
1
0
0
8/31/2020 3:07 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 8
1=nRna Rangy-.qn17 INPUT Sl1MMARY CHECKLIST REPORT
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
24SIab-On-Grade Edge Insulatio
HALL 3 ft
0
52 ft2
-
1 0
0
25SIab-On-Grade Edge Insulatio
BEDROOM 4 13 ft
0
182 ft2
_
1 0
0
26SIab-On-Grade Edge Insulatio
GAME ROOM 42 ft
0
216 ft2
-
1 0
0
278Iab-On-Grade Edge Insulatio
AHU CLST 1 ft
0
12 ft2
-
1 0
0
ROOF
/
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V #
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Composition shingles 3564 ft2
0 ft2
Medium
N
0.4
No 0.9
No 20
26.6
ATTIC
IRCC
V #
Type
Ventilation Vent Ratio (1
in)
Area
RBS
1
Full attic
Unvented
0
3187
ft2
N
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented)
UTILITY RM
0
Blown
120 ft2
0.1
Wood
2
Under Attic (Unvented)
HALLWAY
0
Blown
102 ft2
0.1
Wood
3
Under Attic (Unvented)
POWDER RM
0
Blown
42 ft2
0.1
Wood
4
Under Attic (Unvented)
PANTRY
0
Blown
28 ft2
0.1
Wood
5
Under Attic (Unvented)
M BATH
0
Blown
190 ft2
0.1
Wood
6
Under Attic (Unvented)
M WIC
0
Blown
119 ft2
0.1
Wood
7
Under Attic (Unvented)
M HALL
0
Blown
35 ft2
0.1
Wood
8
Under Attic (Unvented)
M TOILET
0
Blown
30 ft2
0.1
Wood
9
Under Attic (Unvented)
MASTER BEDRO
0
Blown
272 ft2
0.1
Wood
10
Under Attic (Unvented)
KITCHEN/DININ
0
Blown
480 ft2
0.1
Wood
11
Under Attic (Unvented)
OFFICE
0
Blown
143 ft2
0.1
Wood
12
Under Attic (Unvented)
GREAT ROOM
0
Blown
440 ft2
0.1
Wood
13
Under Attic (Unvented)
FOYER
0
Blown
60 ft2
0.1
Wood
14
Under Attic (Unvented)
WIC 2
0
Blown
30 ft2
0.1
Wood
15
Under Attic (Unvented)
BEDROOM 2
0
Blown
168 ft2
0.1
Wood
16
Under Attic (Unvented)
BEDROOM 3
0
Blown
165 ft2
0.1
Wood
17
Under Attic (Unvented)
HALL 2
0
Blown
69 ft2
0.1
Wood
18
Under Attic (Unvented)
WIC 3
0
Blown
40 ft2
0.1
Wood
19
Under Attic (Unvented)
LINEN
0
Blown
12 ft2
0.1
Wood
20
Under Attic (Unvented)
SINKS
0
Blown
36 ft2
0.1
Wood
21
Under Attic (Unvented)
TOILET
0
Blown
36 ft2
0.1
Wood
22
Under Attic (Unvented)
BATH 3
0
Blown
78 ft2
0.1
Wood
23
Under Attic (Unvented)
WIC
0
Blown
30 ft2
0.1
Wood
24
Under Attic (Unvented)
HALL
0
Blown
52 ft2
0.1
Wood
25
Under Attic (Unvented)
BEDROOM 4
0
Blown
182 ft2
0.1
Wood
26
Under Attic (Unvented)
GAME ROOM
0
Blown
216 ft2
0.1
Wood
27
Under Attic (Unvented)
AHU CLST
0
Blown
12 ft2
0.1
Wood
8/31/2020 3:07 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 8
MRM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
Space
1
E
Exterior
Concrete Block - Int Insf11TILITY RM
5
10
0
10
0
100.0 ft2
0
0
0.4
0
_ 2
N
Garage
Frame - Wood UTILITY RM
13
11
0
10
0
110.0 ft2
0
0.1
0.4
0
_ 3
E
Garage
Frame - Wood HALLWAY
13
4
0
10
0
40.0 ft2
0
0.1
0.4
0
_ 4
N
Garage
Frame - Wood HALLWAY
13
6
0
10
0
60.0 ft2
0
0.1
0.4
0
5
W
Exterior
Concrete Block - Int InstROWDER R
5
2
0
10
0
20.0 ft2
0
0
0.4
0
-6
N
Garage
Frame - Wood POWDER R
13
7
0
10
0
70.0 ft2
0
0.1
0.4
0
7
E
Exterior
Concrete Block - Int Insul M BATH
5
16
0
10
0
160.0 ft2
0
0
0.4
0
8
E
Exterior
Concrete Block - Int InsuM TOILET
5
6
0
.10
0
60.0 ft2
0
0
0.4
0
9
E
Exterior
Concrete Block - Int Ins81ASTER BE
5
16
0
10
0
160.0 ft2
0
0
0.4
0
10
S
Exterior
Concrete Block - Int Ins01ASTER BE
5
17
0
10
0
170.0 ft2
0
0
0.4
0
11
W
Exterior
Concrete Block - Int Ins61ASTER BE
5
6
0
10
0
60.0 ft2
0
0
0.4
0
12
S
Exterior
Concrete Block - Int Ins9ITCHEN/DI
5
15
0
10
0
150.0 ft2
0
0
0.4
0
13
W
Exterior
Concrete Block - Int InsdKITCHEN/DI
5
10
0
10
0
100.0 ft2
0
0
0.4
0
14
N
Exterior
Concrete Block - Int Insul OFFICE
5
13
0
10
0
130.0 ft2
0
0
0.4
0
15
W
Exterior
Concrete Block - Int Insul OFFICE
5
6
0
10
0
60.0 ft2
0
0
0.4
0
16
S
Exterior
Concrete Block - Int Ins(IREAT ROO
5
20
0
14
0
280.0 ft2
0
0
0.4
0
17
N
Exterior
Concrete Block - Int Insul FOYER
5
10
0
10
0
100.0 ft2
0
0
0.4
0
18
N
Exterior
Concrete Block - Int InsBEDROOM 2
5
12
0
10
0
120.0 ft2
0
0
0.4
0
19
E
Exterior
Concrete Block - Int InsBEDROOM 2
5
13
0
10
0
130.0 ft2
0
0
0.4
0
20
N
Exterior
Concrete Block - Int InsBEDROOM 3
5
11
0
10
0
110.0 ft2
0
0
0.4
0
21
E
Exterior
Concrete Block - Int InsBEDROOM 3
5
1
0
10
0
10.0 ft2
0
0
0.4
0
22
W
Exterior
Concrete Block - Int InsBEDROOM 3
5
15
0
10
0
150.0 ft2
0
0
0.4
0
23
W
Exterior
Concrete Block - Int Insul WIC 3
5
5
0
10
0
50.0 ft2
0
0
0.4
0
24
W
Exterior
Concrete Block - Int Insul TOILET
5
6
0
10
0
60.0 ft2
0
0
0.4
0
25
W
Exterior
Concrete Block - Int Insul WIC 4
5
6
0
10
0
60.0 ft2
0
0
0.4
0
26
E
Exterior
Concrete Block - Int Insul HALL
5
3
0
10
0
30.0 ft2
0
0
0.4
0
27
W
Exterior
Concrete Block - Int InsBEDROOM 4
5
13
0
10
0
130.0 ft2
0
0
0.4
0
28
E
Exterior
Concrete Block - Int InsdSAME ROO
5
12
0
10
0
120.0 ft2
0
0
0.4
0
29
S
Exterior
Concrete Block - Int InsdSAME ROO
5
18
0
10
0
180.0 ft2
0
0
0.4
0
30
W
Exterior
Concrete Block - Int InsdSAME ROO
5
12
0
10
0
120.0 ft2
0
0
0.4
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Insulated HALLWAY
None
.4
2
8
8
21.3 ft2
2
N
Insulated FOYER
None
.4
3
8
24 ft2
8/31/2020 3:07 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 8
7 INPUT 5UMMAKY GFIEGKLI5l
WINDOWS
V #
Omt
Wall
ID
Frame
Panes
1
E
1
Metal
Low-E Single
2
E
7
Metal
Low-E Single
3
E
7
Metal
Low-E Single
4
E
8
Metal
Low-E Single
5
E
9
Metal
Low-E Single
6
S
10
Metal
Low-E Single
7
S
12
Metal
Low-E Single
8
W
13
Metal
Low-E Single
9
N
14
Metal
Low-E Single
10
S
16
Metal
Low-E Single
11
S
16
Metal
Low-E Single
12
S
16
Metal
Low-E Single
13
N
17
Metal
Low-E Single
14
N
18
Metal
Low-E Single
15
N
20
Metal
Low-E Single
16
W
22
Metal
Low-E Single
17
W
24
Metal
Low-E Single
18
W
27
Metal
Low-E Single
19
S
29
Metal
Low-E Single
20
E
9
Metal
Low-E Single
# Floor Area Ceiling A
1 720 ft2 720 ft2
NFRC
rea
U-Factor SHGC 1
Yes
0.58
0.24
Yes
0.45
0.26
Yes
0.58
0.24
Yes
0.58
0.24
Yes
0.45
0.26
Yes
0.58
0.24
Yes
0.58
0.24
Yes
0.58
0.24
Yes
0.58
0.24
Yes
OA5
0.26
Yes
0.45
0.26
Yes
0.65
0.21
Yes
0.65
0.21
Yes
0.58
0.24
Yes
0.62
0.22
Yes
0.45
0.26
Yes
0.45
0.26
Yes
0.58
0.24
Yes
0.6
0.24
Yes
0.45
0.26
GARAGE
Exposed Wall Perimeter
28 ft
INFILTRATION
mp Area
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Overhang
Depth Separatic
9.0ft2
2ft0in
1ft4in
6.9ft2
2ft0in
1ft4in
12.0ft2
2ft0in
1ft4in
9.0ft2
2ft0In
1ft4in
7.0ft2
2ft01n
1ft4in
45.0ft2
2ft0in
1ft4in
23.1 ft2
8 ft 01n
1 ft 4 in
48.0ft2
8ft0in
1ft4in
36.0ft2
10ft0in
1ft4in
4.7ft2
18ft0in
1ft4in
15.0ft2
18ft0in
1ft4in
96.0ft2
18ft0in
1ft4in
8.6ft2
16ft0In
1ft4in
36.0ft2
2ft0in
1ft4in
20.0ft2
2ft0in
1ft4in
6.0ft2
2ft0in
1ft41n
6.0ft2
2ft0in
1ft4in
30.01`12
2ft0in
1ft4in
40.0ft2
2ft0in
1ft4in
33.1ft2
2ft0in
1ft4in
Wall
loft
Int Shade
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
Wall Insulation
13
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
# Scope
Method
SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse
Proposed ACH(50)
.000469
3923.5 215.39 405.08 .1817
7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/
None
COPA 34 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR
Block
Ducts
1
Central Unit/
Split
Singl SEER: 16 58 kBtu/hr 1740 cfm
0.8
1
sys#1
8/31/2020 3:07 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 8
FORM R4n5-9n17 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.98
50 gal
62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System
Model # Collector Model
# Area Volume
FEF
None None
ft2
DUCTS
/ — Supply —
— Return —
Air
CFM 25
CFM25
HVAC #
v # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6 250 ft2
Attic
25 ft2
Default Leakage
AHU CLST
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Fe
HIM
[Xj
Jun [ ]Jul
n
Aug
[�j Sep
L J Sep
Oct Nov
� Oct � Nov
Dec
� Dec
Venting Jan
Mar
Apr
ay
Jun [ ] Jul
Aug
l 1 Sep
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10 11
12
Coding (WD) AM
78
78
78
78
78 78
78
78
80 80 80
80
PM
80
80
80
80
78 78
78
78
78 78 78
78
Cooling (WEH) AM
78
78
76
78
78 78
78
78
80 80 80
80
PM
80
80
80
80
78 78
78
78
78 78 78
78
Heating (WD) AM
65
65
65
65
65 65
65
68
68 68 68
68
PM
68
68
68
68
68 68
68
68
68 68 68
68
Heating (WEH) AM
65
65
65
65
65 65
65
68
68 68 68
68
PM
68
68
68
68
68 68
68
68
68 68 68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Defauft(8 Ibs/sq.fL
0 ft2
Oft
0.3
UTILITY RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
POWDER RM
Default(8 Ibs/sq.fL
ft2
ft
0.3
PANTRY
Default(8 Ibs/sq.fL
ft2
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M TOILET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8lbs/sq.ft.
ft2
ft
0.3
KITCHEN/DINING
Default(8 Ibs/sq.ft.
ft2
ft
0.3
OFFICE
Default(8 Ibs/sq.ft.
ft2
ft
0.3
GREAT ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.fL
ft2
ft
0.3
WIC 2
Default(8 lbs/sq.fL
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.fL
ft2
ft
0.3
BEDROOM 3
8/31/2020 3:07 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 8
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LINEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
SINKS
Default(8 Ibs/sq.ft.
ft2
ft
0.3
TOILET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
GAME ROOM
Default(8 Ibs/s .ft.
ft2
ft
0.3
AHU CLST
8/31/2020 3:07 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 8 of 8
23'
o r
o,
IZA
� i LIO
29 ,Ili1
❑ 7080
ISD
WI
1
N
1
IN
20' -811
29' -411
Front Forth to
Be %Ucco
Colling
N
WI0
rr10l, Knee Wall with Ind post, Shower 61a55 and Shower Water Supply Area With Two Neal And Two Val os
NB 5N23 pum W/ W9 WI O W8 C 3)
�" "'',iU LI L5 ransom �020 L9 SH33 LI 51123 CD Transom 1616
WASHER DRYER 8 ,/a l 7 5' 6 1 1 1\1015e Insulation 2oi
9'-611 41-411 4 LI W6
Lltilitq Loom iLFA5' -I' 51125
91 _2119' 6'' x I I' 11 3 post 2680p 3' -10" 2680p
h2 80 3'-6ii 11,5i1
2l1680 1680 Master Bedroom88POP r�on 6or7 16 ,gii 6+HB '
Master Closet 6' -8" 4' -911
6i-QII ( I C-) 1411 x1 6'-/iII
2880 5 288 16 14 -q i 1 3080
2-480 9
r7r�� Teader
6' -2" '2 OverMap" ,911 B. gamed Wall To
2880 �r Match Kitchen Wall
I 3-II
i9' Header 17 2 8�1 13 -�
5 -q 10-
o% f'efriq 5 nW V�
3' ,
HPwater L ne -� l -
egress t
288 o
W2 12i,511 7''S"
- C 2) 5H26 Office _ 20' -1111
L7 2 6 1 1 XI O' 6" 2 I3 "11 9' Header
n 2880 ------------ --_ _
2' o
L er
f
❑❑ 10 o oa❑❑ o0,0 -
o� �121
\-Y\ 3080 LZ s 9' -21 Grew Room
L3
03
L3
egress
W2
1 ,511 C 2) 5H26
0' 1011x20 CLI
' -8"
M
_12i,811
6,
Bedroom 2680P 20'
II'-9i1 #2 n
2' _ 30809
I ' 8" x 12' 8" 41 g� 1 080 2880 ;311
2880 9 -711 248 _ . 121-611
RI
10' Cc it inq He fight throughout C--5;5
10'811 Bedroom #Vaul d Ceiling In Great Room With i2 Ritch 32boor Ca5inq throughout 10'6i'xI�'"L
Round Corner Bead throughout
266OF
0 41 - 6
268 p
2680P =t
Ff �7*
3 i -211
30 Op
is
268OF Bedroom # 4
611 11 ' 10''xl 2' 6''
Backing For
Barn boor
T -1 O
L16
b3
6080
9'-QII
LII
b2
12080
2880
/ AI
L
L� WI:�,
22505H
WI
22505N
D
5' -211
egress
(D W6
5H25
2' -1111
6' -611
Pear Forth; tongue
& Groove Rine Bq
Owner -
o �
S
6' -211
M
16'-8'1
Game Room
16'6''xlI'6''
so Insulation
L5 +NB L5 W5 egress egress O ,
LI L6
M fransom fransom W6 W6 z
1 i1
2 4016 4020 51125 51125
1,qn
t1-115 POCUMNf 15 PPC)M MY, FOR U51� BY CLIFNf ANn PF516NAt�19 R�CIMNf5 ONLY, OFFICIAL RLAN5 BY JAVER C15NFR05, R,�, MIU5f HAVF 51 A, WITH ORIGINAL 516NATURF,
egress
W7
HFMO} 0
0
0 Lintel 5chedule 0
NO
Lintel focal
Length
Lintel
Capacity{
Max,
Applied
Load
fiesignation
femarks
LI
3' 811
3069
1517
8F8-lf,l[3
1,2
61211
1451
124
8F8-lf,ll3
1,3
6' II"
1011
497
8F840
1,4
4'
II11
1663
1291
8F8-IT,II3
L5
' 811
3090
2176
81`124,10
1,6
31811
611-5
4238
8F164,10
1,7
8400
6778
8F24
5ee betail FApL page A3
1,8
21211
3069
1225
8F840
If fruss Kl lands on Lintel
flue To rield Conditions,
Advise engineer
1,9
51111
1663
496
8F840
1,10
-71811
044
1410
8F1640
1,11
16'8''
300
100
8F8-IT,113
12' 510inq & fransom
1,12
10,011
153
637
8F164,16
1,13
-1411
6153
637
8F16-If,IP
Sized to Match Lintel 12
L14
3' 211
3069
2744
8F8-IT,If3
1,15
16'8"
2500
1860
8F24
5ee Pe -Lail FApL page A3
1,16
7'
1729
909
81124,0
1,17
12'811
471
100
8F8-If,IP
Openinq To 56P
E
c�
� O
o �
Nominal Number Of # 5 Bar5 \s�
Ne fight at Bottom of L intel
Nominal 8F16-0/ If
Width Number Of # 5 Bars 9,
Filled Or At fop Of L Intel O 421
Unfilled O
Beam f%esignation
Composite Reinforced Concrete Beams U5inqco
Pre-Ca5t And Ire-%re55ed Concrete Lintels O
C' Ca5t-Crete" or Fct,) & Standard Ma5onr� Units o o
A o
Full 5ize " - I '
8 �
Christopher & 5hana Cicio
1807 Hazelwood Prive
Fort pierce, Florida 349821 2 s -ems l
Contractor; GemBuildersfOPiNCCoCMLA
T.
F I oor Plan: ! I i . I i ! BOCc
8PILIF -UP,
R2 P: 2020-028 1 n, 03/ 01 / 20 1 A,02 / All
Window pemoved per 1�pI 4C �ngineerinq, I �I �C
Owner Purinq Construction �` ` Javi C 15nero5, h , # 70844REVIS10N
5903 e v 1112
r13 2
4CFngLLC@ ail,com c,772-519-2679
OD