Loading...
HomeMy WebLinkAboutRESPONSE TO COMMENTS,WS 9 - Cover, Arch, WP, Ele, Plu - S&S 9.9.2020K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______THESE PLANS HAVE BEEN PREPARED TO MEET THE REQUIREMENTSOF THE FLORIDA BUILDING CODE, 6th Edition (2017) RESIDENTIALw/ APPLICABLE SUPPLEMENTSOCCUPANCY: R3BUILDING TYPE: VBSPRINKLED: NOFLOOD ZONE: ’X’TERMITE PROBABILITY: VERY HEAVYLOT009ABBREVIATIONSMASMATMAXMCMINM.O.MTLN.I.C.(NTS)OHGDOPEROPNGOPTOSBOZ1/R1/SPCPNLPLYWDPREFABPRPROJPSIPSFP.T.QUADREFREINFREQ’DRNGR.O.RRNDMASONRYMLMATERIALMAXIMUMMEDICINE CABINETMINIMUMMICRO LAMMASONRY OPENINGMETALNOT IN CONTRACTNOT TO SCALEOVERHEAD GARAGE DOOROPERATOROPENINGOPTIONALORIENTED STRAND BOARDOUNCEONE RODONE SHELFPRECASTPANELPLYWOODPREFABRICATEDPAIRPROJECTEDPOUNDS PER SQUARE INCHPOUNDS PRE SQUARE FOOTPRESSURE TREATEDQUADRUPLEREFRIGERATORREINFORCEDREQUIREDRANGEROUGH OPENINGRISERROUNDMECHMECHANICALMIRMIRRORABA.F.F.ADJ.ALUM.ANCH@BD.BLDG.BM.BLKGBRG.BRK.C.J.CMUCOL.CONC.COND.CONT.CANT.CLG.CMCRDdDBL.DIA.DIR.DNDRDWDWGD.S.DTLEA.E.J.ELEC.CLBFANCHOR BOLTABOVE FINISH FLOORADJUSTABLEALUMINUMANCHORANGLEATBOARDBI−FOLDBUILDINGBEAMBLOCKINGBEARINGBRICKCONTROL JOINTCENTER LINECONCRETE MASONRY UNITCOLUMNCONCRETECONDITIONCONTINUOUSCANTILEVERCEILINGCROWN MOLDINGCHAIR RAIL DRYERPENNYDOUBLEDIAMETERDIRECTIONDOWNDOORDISH WASHERDRAWINGDOWNSPOUTDETAILEACHEXPANSION JOINTELECTRICALB.O.BOTTOM OFO.C.ON CENTERPKTPOCKET DOOROBSOBSCUREDB.P.BI−PASS DOORPDSPULL−DOWN STAIRFDFND.FLR.FPFRFRMFTGGA.GALV.GCGENGYP.GLHGT.HDR.HBINSUL.INT.LTFLOOR DRAINFOUNDATIONFLOORFIREPLACEFIRE RATEDFRAMEFOOTINGGAUGEGALVANIZEDGENERAL CONTRACTORGENERALGYPSUMGLUE LAMHEIGHTHEADERHOSE BIBBINSULATIONINTERIORLAUNDRY TUBHCHOLLOW COREHORIZ.HORIZONTALFINISHED FLOORFIN.LAVATORYLAV.ELEVEQ.EQUIP.EXPEXT.EEELEVATIONEQUALEQUIPMENTEXPANSIONEXTERIOREACH ENDFXDFIXEDGLSGLASSHHIGHR&SSCSCHEMSHLFSHTSIMS.S.STLSTRUCTSUSPSGDSQTBT&GTYPTTRTRPLU.N.O.VERTV.L.I.F.WW/WDWWMWDWROD AND SHELFSOLID CORESCHEMATICSHELFSHEETSIMILARSTAINLESS STEELSTEELSTRUCTURALSUSPENSIONSLIDING GLASS DOORSQUARETOWEL BARTONGUE AND GROOVETYPICALTREADTOWEL RODTRIPLEUNLESS NOTED OTHERWISEVERTICALVERIFY LOCATION IN FIELDWASHERWITHWOODWELD WIRE MESHWINDOWWCWATER CLOSETSINGLE HUNGSHSHOWERSHWRTEMPTEMPEREDT.O.TOP OF RELEASE HISTORYTERMITE PROTECTION SHALL BE PROVIDED BY DOMINION2L TERMITICIDE/INSECTICIDE. UPON COMPLETION OF THEAPPLICATION OF THE TERMITE PROTECTIVE TREATMENT,A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THEBUILDING DEPARTMENT BY THE LICENSED PESTCONTROL COMPANY THAT CONTAINS THE FOLLOWINGSTATEMENT: "THE BUILDING HAS RECEIVED A COMPLETETREATMENT FOR THE PREVENTION OF SUBTERRANEANTERMITES. TREATMENT IS IN ACCORDANCE WITH RULESAND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENTOF AGRICULTURE AND CONSUMER SERVICES."90 Matawan RoadMatawan, NJ 07747(732) 383−2200TMFRONT & REAR ELEVATIONSFIRST FLOOR PLANCOVERSHEET & BUILDING DATAA2.1A1.1CS.1CS.2A2.2ROOF PLANA5.1 BUILDING SECTIONSA5.2 TYPICAL WALL SECTIONSGENERAL NOTESDRAWING INDEXFIRST FLOOR ELECTRICAL PLANE1.1SLAB PENETRATION PLANP1.1SIDE ELEVATIONSA3.1STRUCTURAL NOTESS−0.0F−1.0BLOCK PLANS−1.3 ROOF FRAMING PLANSD−1 FOUNDATION DETAILSSTRUCTURAL DETAILSSD−2SLAB PLANF−2.0STRUCTURAL DETAILSPBSB−1WP1WATERPROOFING DETAILS1917 SQ. FT.380 SQ. FT."A"ELEVATION1ST FLR/TOTAL A/CENTRYGARAGETOTAL UR2381 SQ. FT.84 SQ. FT.CS1COVER SHEET &BUILDING DATA16,614 CU. FT.TOTAL VOLUME 1. THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE ANDITS ATTIC AREA BY NOT LESS THAN 1/2 INCH (12.7 mm) GYPSUMBOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATHHABITABLE ROOMS SHALL BE SEPARATED FROM ALL HABITABLEROOMS ABOVE BY NOT LESS THAN 5/8 INCH (15.9 mm) TYPE "X"GYPSUM BOARD OR EQUIVALENT. WHERE THE SEPARATION IS AFLOOR-CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THESEPARATION SHALL ALSO BE PROTECTED BY NOT LESS THAN 1/2INCH (12.7 mm) GYPSUM BOARD OR EQUIVALENT.1. SHALL BE 5/8" THICKTEXTURED PER COMMUNITY STANDARDS.2. SHALL BE 7/8"THICK (3) COAT STUCCO OVER (2) LAYERS OF WATER RESISTANTBARRIERS IN ACCORDANCE WITH FLORIDA BUILDING CODE 6THEDITION (2017) RESIDENTIAL, R703 AND ASTM C926. TEXTURE PERCOMMUNITY1. FLASHING SHALL BE INSTALLED AT WALL AND ROOFINTERSECTIONS, DECK AND WALL INTERSECTIONS, AT GUTTERS,AT ALL CHANGES IN ROOF SLOPE OR DIRECTION, AND AROUNDROOF OPENINGS.2. APPROVED CORROSION-RESISTANT FLASHING SHALL BE APPLIEDSHINGLE-FASHION IN A MANNER TO PREVENT ENTRY OF WATERINTO THE WALL CAVITY OR PENETRATION OF WATER TO THEBUILDING STRUCTURAL FRAMING COMPONENTS. SELF-ADHEREDMEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711.THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIORWALL FINISH. APPROVED CORROSION-RESISTANT FLASHINGSSHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS:3. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING ATEXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND TO THESURFACE OF THE EXTERIOR WALL FINISH OR TO THEWATER-RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE.FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL BEINSTALLED IN ACCORDANCE WITH ONE OR MORE OF THEFOLLOWING:THE FENESTRATION MANUFACTURER’S INSTALLATION ANDFLASHING INSTRUCTIONS, OR FOR APPLICATIONS NOTADDRESSED IN THE FENESTRATION MANUFACTURERSINSTRUCTIONS, IN ACCORDANCE WITH THE FLASHINGMANUFACTURERS INSTRUCTIONS. WHERE FLASHINGINSTRUCTIONS OR DETAILS ARE NOT PROVIDED, PAN FLASHINGSHALL BE INSTALLED AT THE SILL OF EXTERIOR WINDOW ANDDOOR OPENINGS. PAN FLASHING SHALL BE SEALED OR SLOPEDIN SUCH A MANNER AS TO DIRECT WATER TO THE SURFACE OFTHE EXTERIOR WALL FINISH OR TO THE WATER−RESISTIVEBARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PANFLASHING SHALL ALSO INCORPORATE FLASHING OR PROTECTIONAT THE HEAD AND SIDES.IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF AREGISTERED DESIGN PROFESSIONAL.IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200. FMA/WDMA250, OR FMA/AAMA/WDMA 3001. WINDOWS SHALL BE INSTALLED AND FLASHED IN ACCORDANCEWITH THE MANUFACTURERS WRITTEN INSTALLATIONINSTRUCTIONS. WRITTEN INSTALLATION INSTRUCTIONS SHALL BEPROVIDED BY THE MANUFACTURER FOR EACH WINDOW.:PLAN MEETS OR EXCEEDS FEMA FLOOD FINISHED GARAGEFLOOR ELEVATION. :1. WIND RESISTANCE OF ASPHALT SHINGLES. - ASPHALTSHINGLES SHALL BE INSTALLED IN ACCORDANCE WITHSECTION R905.2.6 AND R905.2.6.1.:1. WHEN STANDARD OR OPTIONAL FIREPLACE IS TO BE INSTALLEDTHE CHIMNEY MUST EXTEND 3'-0" PAST THE HIGHER POINT WHEREIT EXTENDS THROUGH THE ROOF AND MUST BE 2'-0" HIGHER THANTHE ROOF OR RIDGE THAT IS 10'-0" AWAY OR CLOSER.:1. CEMENT, FIBER-CEMENT, OR GLASS MAT GYPSUM BOARD (NOGREEN BOARD ALLOWED) IN COMPLIANCE WITH ASTM C1288,C1325, OR C1178 AND INSTALLED IN ACCORDANCE WITHMANUFACTURER RECOMMENDATIONS SHALL BE USED ASBACKERS FOR WALL TILE IN TUB AND SHOWER AREAS, AND WALLPANELS IN SHOWER AREAS.:1. ENERGY CALCULATIONS FOR HEATING AND COOLINGCAPACITIES SHALL BE FURNISHED BY THE GENERALCONTRACTOR AS AN ATTACHMENT TO THIS PLAN SET AT THETIME OF APPLICATION FOR PERMIT.2. MECHANICAL APPLIANCES SHALL BE ACCESSIBLE FORINSPECTION, SERVICE, REPAIR, AND REPLACEMENT WITHOUTREMOVING PERMANENT CONSTRUCTION, OTHER APPLIANCES,OR ANY OTHER PIPING OR DUCTS NOT CONNECTED TO THEAPPLIANCE BEING INSPECTED, SERVICED, REPAIRED, ORREPLACED. A LEVEL WORKING SPACE AT LEAST 30 INCHES (762mm) DEEP AND 30 INCHES (762 mm) WIDE SHALL BE PROVIDED INFRONT OF THE CONTROL SIDE TO SERVICE AN APPLIANCE.3. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS ORCEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALLBE CONSTRUCTED OF A MIN. #26 GAUGE (0.48 mm) SHEET STEEL OROTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTOTHE GARAGE.4. FOUNDATIONS AND SUPPORTS FOR OUTDOOR MECHANICALSYSTEMS SHALL BE RAISED AT LEAST 3 INCHES (76 mm) ABOVETHE FINISHED GRADE AND SHALL ALSO CONFORM TO THEMANUFACTURER'S INSTALLATION INSTRUCTIONS.5. AUXILIARY DRAIN PAN. CATEGORY IV CONDENSINGAPPLIANCES SHALL BE PROVIDED WITH AN AUXILIARY DRAINPAN WHERE DAMAGE TO ANY BUILDING COMPONENT WILLOCCUR AS A RESULT OF STOPPAGE IN THE CONDENSATE DRAINPIPING SYSTEM. THESE PANS SHALL BE INSTALLED INACCORDANCE WITH THE APPLICABLE PROVISIONS OF SECTIONSM1411.3.:1. OUTDOOR DISCHARGE. THE AIR REMOVED BY EVERYMECHANICAL EXHAUST SYSTEM SHALL BE DISCHARGED TO THEOUTDOORS. AIR SHALL NOT BE EXHAUSTED INTO AN ATTIC,SOFFIT, RIDGE VENT OR CRAWL SPACE.2. EXHAUST AIR FROM BATH ROOMS AND TOILET ROOMS SHALLNOT BE RECIRCULATED WITHIN A RESIDENCE OR TO ANOTHERDWELLING UNIT AND SHALL BE EXHAUSTED DIRECTLY TO THEOUTDOORS. EXHAUST AIR FROM BATHROOMS AND TOILET ROOMSSHALL NOT DISCHARGE INTO AN ATTIC, CRAWL SPACE, OR OTHERAREAS INSIDE THE BUILDING.3. DUCT LENGTH: THE MAXIMUM LENGTH OF A CLOTHES: DRYEREXHAUST DUCT SHALL NOT EXCEED 35 FEET. THE DRYER LOCATIONTO THE WALL OR ROOF TERMINATION. THE MAXIMUM LENGTH OFTHE DUCT SHALL BE REDUCED 2.5 FEET (762 mm) FOR EACH 45DEGREE (0.79 RAD) BEND AND 5 FEET (1524 mm) FOR EACH 90 DEGREE(1.6 RAD) BEND. THE MAXIMUM LENGTH OF THE EXHAUST DUCTDOES NOT INCLUDE THE TRANSITION DUCT. EXCEPTION - WHERE ACLOTHES DRYER BOOSTER FAN IS INSTALLED AND LISTED ANDLABELED FOR THE APPLICATION, THE MAXIMUM LENGTH OF THEEXHAUST DUCT, INCLUDING ANY TRANSITION DUCT, SHALL BEPERMITTED TO BE IN ACCORDANCE WITH THE BOOSTER FANMANUFACTURER'S INSTALLATION INSTRUCTIONS. WHERE ACLOTHES DRYER BOOSTER FAN IS INSTALLED AND NOT READILYACCESSIBLE FROM THE ROOM IN WHICH THE DRYER IS LOCATED, APERMANENT IDENTIFYING LABEL SHALL BE PLACED ADJACENT TOWHERE THE EXHAUST DUCT ENTERS THE WALL. THE LABEL SHALLBEAR THE WORDS "THIS DRYER EXHAUST SYSTEM IS EQUIPPEDWITH A REMOTELY LOCATED BOOSTER FAN."4. PROVIDE LOUVER DEVICES AT INTAKE ANDEXHAUST LOCATIONS IN ACCORDANCE WITHAMCA STANDARD 550 IN FBC.: ISSUANCE OFPLANS FROM THIS OFFICE SHALL NOT RELIEVE THE BUILDER OFRESPONSIBILITY TO REVIEW AND VERIFY ALL NOTES, DIMENSIONS,AND ADHERENCE TO APPLICABLE BUILDING CODES PRIOR TOCOMMENCEMENT OF ANY CONSTRUCTION. ANY DISCREPANCY OFERROR IN NOTES, DIMENSIONS, OR ADHERENCE TO APPLICABLEBUILDING CODES SHALL BE BROUGHT TO THE ATTENTION OF THEDRAFTER'S OFFICE FOR CORRECTION BEFORE COMMENCEMENT OFANY CONSTRUCTION CORRECTION / REVISIONS. ANY REVISIONS ORCHANGES, NOT RELATED TO THE CORRECTION OF ERRORS THATARE MADE AFTER THE FINAL PLANS HAVE BEEN COMPLETEDSHALL BE SUBJECT TO ADDITIONAL FEES. IF ANY MODIFICATIONSARE MADE TO THESE PLANS BY ANY OTHER PARTY OTHER THANTHE DRAFTER'S OFFICE, THE DRAFTER SHALL NOT BE HELDRESPONSIBLE.:A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OFTHE SURVEY SHALL BE ON SITE FOR THE BUILDING INSPECTOR'SUSE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND ASTRING STRETCHED FROM MARKER TO MARKER TO VERIFYREQUIRED SETBACKS.ALL PLUMBING, ELECTRICAL, AND MECHANICAL ROUGH INSMUST BE COMPLETE, INSPECTED, AND APPROVED BEFOREREQUESTING THE FRAMING INSPECTION (FBC 110.6):MINIMUM SIZE.EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE AMINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET.EXCEPTION:1. ALL GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NETCLEAR OPENING OF 5 SQ FT.MAXIMUM HEIGHT FROM FLOOR:EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE THEBOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44 INCHESMEASURED FROM THE FLOOR.2. OPERATIONAL CONSTRAINTS:EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BEOPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USEOF KEYS OR TOOLS. BARS, GRILLES, GRATES OR SIMILAR DEVICESARE PERMITTED TO BE PLACED OVER EMERGENCY ESCAPE ANDRESCUE OPENINGS PROVIDED THE MINIMUM NET CLEAR OPENINGSIZE COMPLIES WITH SECTION 1030.4 AND SUCH DEVICES SHALLBE RELEASABLE OR REMOVABLE FROM THE INSIDE WITHOUT THEUSE OF A KEY, TOOL OR FORCE GREATER THAN THAT WHICH ISREQUIRED FOR NORMAL OPERATION OF THE ESCAPE AND RESCUEOPENING.3. FALL PROTECTION:WHERE THE OPENING OF THE SILL PORTION OF AN OPERABLEWINDOW IS LOCATED MORE THAN 72 INCHES (1829 MM) ABOVETHE FINISHED GRADE OR OTHER SURFACE BELOW, THE LOWESTPART OF THE CLEAR OPENING OF THE WINDOW SHALL BE AT AHEIGHT NOT LESS THAN 24 INCHES (610 MM) ABOVE THE FINISHEDFLOOR SURFACE OF THE ROOM IN WHICH THE WINDOW ISLOCATED. GLAZING BETWEEN THE FLOOR AND A HEIGHT OF 24INCHES (610 MM) SHALL BE FIXED OR HAVE OPENINGS THROUGHWHICH A 4-INCH (102 MM) DIAMETER SPHERE CANNOT PASS.EXCEPTION: OPENINGS THAT ARE PROVIDED WITH WINDOWGUARDS THAT COMPLY WITH ASTM F 2006 OR F 2090.:PER SECTION R302.5, R302.6, OPENING PROTECTION1. OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOMUSED FOR SLEEPING PURPOSES SHALL NOT BE PERMITTED.OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BEEQUIPPED WITH SOLID OR HONYCOMB CORE STEEL AND NOT LESSTHAN 1 3/8", 20 MINUTE RATED, WITH SELF CLOSER.2. THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE ANDITS ATTIC AREA BY NOT LESS THAN 1/2" GYPSUM BOARD APPLIEDTO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMSABOVE BY NOT LESS THAN 5/8" TYPE "X" GYPSUM BOARD OREQUIVALENT.:THE MAXIMUM RISER HEIGHT SHALL BE 7.75" AND THE MINIMUMTREAD DEPTH SHALL BE 10". THE TREAD DEPTH SHALL BEMEASURED HORIZONTALLY BETWEEN THE VERTICAL PLANES OFTHE FOREMOST PROJECTION OF THE ADJACENT TREADS AND AT ARIGHT ANGLE TO THE TREADS LEADING EDGE. THE MINIMUMWINDER TREAD DEPTH AT THE WALK LINE SHALL BE 10", AND THEMINIMUM WINDER TREAD DEPTH SHALL BE 6". NOSING SHALLNOT BE LESS THAN 3/4" BUT NOT MORE THAN 1 1/4". A NOSINGSHALL NOT BE REQUIRED WHERE THE TREAD DEPTH IS 11".:HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACHCONTINUOUS RUN OF TREADS OR FLIGHTS OF 4 OR MORE RISERS.:HANDRAIL HEIGHT, MEASURED ABOVE STAIR TREAD NOSINGS, ORFINISH SURFACE OF RAMP SLOPE SHALL BE UNIFORM, NOT LESSTHAN 34" AND NOT MORE THAN 38".HANDRAILS WITH A CIRCULAR CROSS-SECTION SHALL HAVE ANOUTSIDE DIAMETER OF AT LEAST 1.25" AND NOT GREATER THAN2" OR SHALL PROVIDE EQUIVALENT GRASPABILITY. IF THEHANDRAIL IS NOT CIRCULAR, IT SHALL HAVE A PERIMETERDIMENSION OF AT LEAST 4" AND NOT GREATER THAN 6.25" WITH AMAXIMUM CROSS-SECTION DIMENSION OF 2.25". EDGES SHALLHAVE A MINIMUM RADIUS OF 0.01".HANDRAIL-GRIPPING SURFACES SHALL BE CONTINUOUS,WITHOUT INTERRUPTION BY NEWEL POSTS OR OTHEROBSTRUCTIONS.EXCEPTIONS:1.HANDRAILS WITHIN DWELLING UNITS ARE PERMITTED TOBE INTERRUPTED BY A NEWEL POST AT A STAIR OR RAMPLANDING.2. WITHIN A DWELLING UNIT, THE USE OF A VOLUTE, TURNOUTOR STARTING EASING IS ALLOWED ON THE LOWEST TREAD.3. HANDRAIL BRACKETS OR BALUSTERS ATTACHED TO THEBOTTOM SURFACE OF THE HANDRAIL SHALL NOT BECONSIDERED OBSTRUCTIONS TO GRASPABILITY, PROVIDEDTHAT THE FOLLOWING CONDITIONS ARE MET:3.1. THEY DO NOT PROJECT HORIZ BEYOND THE SIDES OF THEHANDRAIL WITHIN 1½" OF THE BOTTOM OF THE HANDRAILAND PROVIDED THAT, FOR EACH 1/2" OF ADDITIONALHANDRAIL PERIMETER DIMENSION ABOVE 4", THE VERTICALCLEARANCE DIMENSION OF 1½" CAN BE REDUCED BY 1/8".3.2. THEY HAVE EDGES WITH A RADIUS OF NOT LESS THAN .01".3.3. THEY OBSTRUCT NOT IN EXCESS OF 20 PERCENT OF THEHANDRAIL LENGTH.:CLEAR SPACE BETWEEN A HANDRAIL AND A WALL OR OTHERSURFACE SHALL BE A MINIMUM OF 1.5". A HANDRAIL AND A WALLOR OTHER SURFACE ADJACENT TO THE HANDRAIL SHALL BE FREEOF ANY SHARP OR ABRASIVE ELEMENTS.:SHALL BE LOCATED ALONG OPEN-SIDED WALKING SURFACES,PLATFORMS, STAIRWAYS, RAMPS AND LANDINGS THAT ARELOCATED MORE THAN 30" MEASURED VERTICALLY TO THE FLOOROR GRADE BELOW AT ANY POINT WITHIN 36" HORIZONTALLY TOTHE EDGE OF THE OPEN SIDE. INSECT SCREENING SHALL NOT BECONSIDERED AS A GUARD.:REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THEWALKING SURFACE TO THE REQUIRED GUARD HEIGHT WHICHALLOW THE PASSAGE OF A 4" SPHERE.:PORCHES AND DECKS WHICH ARE ENCLOSED WITH INSECTSCREENING SHALL BE PROVIDED WITH GUARDS WHERE THEWALKING SURFACE IS LOCATED MORE THAN 30" ABOVE THEFLOOR OR GRADE BELOW.:FIREBLOCKING SHALL BE PROVIDED TO CUT OFF ALL VERTICALAND HORIZONTAL CONCEALED DRAFT OPENINGS.:1. GLAZING IN DOORS: GLAZING IN ALL FIXED AND OPERABLE PANELSOF SWINGING, SLIDING, AND BIFOLD DOORS SHALL BE CONSIDERED AHAZARDOUS LOCATION.EXCEPTIONS:1. DECORATIVE GLAZING2. WHEN THERE IS AN INTERVENING WALL OR OTHERPERMANENT BARRIER BETWEEN THE DOOR AND THEGLAZING.3. GLAZING IN WALLS ON THE LATCH SIDE OF ANDPERPENDICULAR TO THE PLANE OF THE DOOR IN A CLOSEDPOSITION.4. WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET ORSTORAGE AREA 3 FEET OR LESS IN DEPTH. GLAZING IN THISAPPLICATION SHALL COMPLY WITH SECTION R308.4.3.5. GLAZING THAT IS ADJACENT TO THE FIXED PANEL OF PATIODOORS.2. GLAZING IN WINDOWS:GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETSALL OF THE FOLLOWING CONDITIONS:1. EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9SQUARE FEET.2. BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR.3. TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR.4. ONE OR MORE WALKING SURFACES WITHIN 36 INCHES (914MM) HORIZONTALLY OF THE GLAZING.3. GLAZING AND WET SURFACES:GLAZING IN WALLS, ENCLOSURES OR FENCES CONTAINING OR FACINGSWIMMING POOLS, HOT TUBS AND SPAS WHERE THE BOTTOM EDGE OF THEGLAZING IS LESS THAN 60 INCHES MEASURED VERTICALLY ABOVE ANYWALKING SURFACE SHALL BE CONSIDERED A HAZARDOUS LOCATION. THISSHALL APPLY TO SINGLE GLAZING AND ALL PANES IN MULTIPLE GLAZING.EXCEPTION: GLAZING THAT IS MORE THAN 60" (1,524 mm), MEASUREDHORIZONTALLY AND IN A STRAIGHT LINE, FROM THE WATER’S EDGE OF ABATHTUB, HOT TUB, SPA, WHIRLPOOL, OR SWIMMING POOL OR FROM THEEDGE OF A SHOWER, SAUNA, OR STEAM ROOM.4. GLAZING ADJACENT TO THE BOTTOM OF A STAIR LANDING:GLAZING ADJACENT TO THE LANDING AT THE BOTTOM OF A STAIRWAYWHERE THE GLAZING IS LESS THAN 36" ABOVE THE LANDING AND WITHIN 60"HORIZONTALLY OF THE BOTTOM TREAD SHALL BE CONSIDERED AHAZARDOUS LOCATION.:IN COMBUSTABLE CONSTRUCTION WHERE THERE IS USABLESPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF AFLOOR/CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLEDSO THAT THE AREA OF THE CONCEALED SPACE DOES NOTEXCEED 1,000 SQUARE FEET. DRAFTSOPPING SHALL DIVIDE THETHE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS.WHERE THE ASSEMBLY IS ENCLOSED BY A FLOOR MEMBRANEABOVE AND A CEILING MEMBRANE BELOW, DRAFTSTOPPINGSHALL BE PROVIDED IN FLOOR/CEILING ASSEMBLIES UNDER THEFOLLOWING CIRCUMSTANCES:1. CEILING IS SUSPENDED.2. FLOOR FRAMING IS CONSTRUCTED OF TRUSS-TYP OPEN-WEBPERFORATED MEMBERS.1. MATERIALS:DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN 1/2"GYPSUM BOARD, 3/8" WOOD STRUCTURAL PANELS OR OTHERAPPROVED MATERIALS ADEQUATELY SUPPORTED.DRAFTSTOPPING SHALL BE INSTALLED PARALLELL TO THEFLOOR FRAMING MEMBERS UNLESS OTHERWISE APPROVED BYTHE BUILDING OFFICIAL. :A 6-MIL POLYETHYLENE OR APPROVED VAPOR RETARDER WITHJOINTS LAPPED NOT LESS THAN 6 INCHES (152 MM) SHALL BEPLACED BETWEEN THE CONCRETE FLOOR SLAB AND THE BASECOURSE OR THE PREPARED SUBGRADE WHERE NO BASECOURSE EXISTS. EXCEPTIONS1. GARAGES, UTILITY BUILDINGS AND OTHER UNHEATEDACCESSORY STRUCTURES.2. FOR UNHEATED STORAGE ROOMS HAVING AN AREA OFLESS THAN 70 SQUARE FEET (6.5 M2) AND CARPORTS.3. DRIVEWAYS, WALKS, PATIOS AND OTHER FLATWORK NOTLIKELY TO BE ENCLOSED AND HEATED AT A LATER DATE.4. WHERE APPROVED BY THE BUILDING OFFICIAL, BASED ONLOCAL SITE CONDITIONS.GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLEMATERIAL.THE AREA OF FLOOR USED FOR PARKING OF AUTOMOBILES OR OTHERVEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDSTO A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY DOORWAY.FLAME SPREAD AND SMOKE DEVELOPED INDEXES FOR WALL ANDCEILING FINISHES SHALL BE IN ACCORDANCE WITH SECTIONS R302.9.1THROUGH R302.9.4.FLAME SPREAD AND SMOKE-DEVELOPED INDEX FOR INSULATION SHALLBE IN ACCORDANCE WITH SECTIONS R302.10.1 THROUGH R302.10.5.CS2GENERAL NOTESK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______ FIRST FLOOR PLAN SCALE: 1/4"=1’−0"*ABRKA1.1FIRST FLOOR PLANK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______2’−11"1’−2" MAX.2x6 STUD WALLSEE PLANS FORWALL LAYOUTSUBFLOORBASE CABINET ASPER SHOP DWG.FINISH FLOORTOP PLATE1/2" GYP.BD.WD.BASEMOLDINGFINISHFLOORSOLID SURFACE COUNTERTOP.INSTALLER TO PROVIDEAPPROPRIATE COUNTERTOPSUPPORT IF REQUIRED2x WOOD/STEEL FRAMEDPARTITIONINTERIOR PARTITION w/INSULATIONCMU WALLCMU WALL w/ FURRING &INSULATIONNOTE: INTERIOR WALLS ARE DRAWNTO ROUGH DIMENSIONSDOORS LOCATED ADJACENT TO WALLINTERSECTIONS ARE TO BE PLACED 3"MEASURED FROM INTERSECTION TODOOR JAMB UNLESS DIMENSIONED ORNOTED OTHERWISE.DOORS LOCATED WITHIN ALENGTH OF WALL ARE TO BECENTERED UNLESSDIMENSIONED OR NOTED OTHERWISE.ABNOTE: TYP. WINDOW HEAD HGT.AT 7’−4" U.N.O. REAR ELEVATIONSCALE: 1/4"=1’−0"FRONT ELEVATIONSCALE: 1/4"=1’−0"NOTE: WRAP THE SAND FINISH TRIM BAND (WHERE SHOWNAROUND WINDOWS & DOORS) INTO THE JAMB, HEAD & SILLOF THE WINDOW & DOORS. PAINT THE BAND, JAMB, HEAD &SILL THE TRIM COLOR.PAINT COLOR SCHEMEBODY COLORTRIM COLORSAND FINISHMEDIUM TEXTURE /SKIP TROWEL FINISHSURFACE TEXTURE / FINISH KEYSTUCCO AND PORTLAND CEMENT PLASTER SHALLBE INSTALLED PER THE CURRENT ASTM C926 & C1063REQUIREMENTS & PROVISIONS OF THE FLORIDA BUILDING CODECONTROL JOINTS IN 3−COAT STUCCO SHALL BE USED TODELINEATE STUCCO AREAS NOT GREATER THAN 144 SQ. FT. ORAT A MAXIMUM DISTANCE OF 18’ BETWEEN JOINTSPER ASTM C1063 (CURRENT EDITION)WEEP SCREED SHALL BE INSTALLED AT STUCCO TRANSITIONS BETWEEN WOOD AND MASONRYAS REQUIRED BY ASTM C1063 (CURRENT EDITION)STUCCO SHALL NOT BE LESS THAN 3 COATS WHEN APPLIEDOVER METAL OR WIRE LATH AND SHALL NOT BELESS THAN 2 COATS WHEN APPLIED OVER MASONRYA2.1FRONT & REAR ELEVATIONSK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______ LEFT ELEVATION SCALE: 1/4"=1’−0"NOTE: WRAP THE SAND FINISH TRIM BAND (WHERE SHOWNAROUND WINDOWS & DOORS) INTO THE JAMB, HEAD & SILLOF THE WINDOW & DOORS. PAINT THE BAND, JAMB, HEAD &SILL THE TRIM COLOR.PAINT COLOR SCHEMEBODY COLORTRIM COLORSAND FINISHMEDIUM TEXTURE /SKIP TROWEL FINISHSURFACE TEXTURE / FINISH KEYSTUCCO AND PORTLAND CEMENT PLASTER SHALLBE INSTALLED PER THE CURRENT ASTM C926 & C1063REQUIREMENTS & PROVISIONS OF THE FLORIDA BUILDING CODECONTROL JOINTS IN 3−COAT STUCCO SHALL BE USED TODELINEATE STUCCO AREAS NOT GREATER THAN 144 SQ. FT. ORAT A MAXIMUM DISTANCE OF 18’ BETWEEN JOINTSPER ASTM C1063 (CURRENT EDITION)WEEP SCREED SHALL BE INSTALLED AT STUCCO TRANSITIONS BETWEEN WOOD AND MASONRYAS REQUIRED BY ASTM C1063 (CURRENT EDITION)STUCCO SHALL NOT BE LESS THAN 3 COATS WHEN APPLIEDOVER METAL OR WIRE LATH AND SHALL NOT BELESS THAN 2 COATS WHEN APPLIED OVER MASONRYRIGHT ELEVATIONSCALE: 1/4"=1’−0"A2.2SIDE ELEVATIONSK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______ 1’−0"5:125:121’−0"1’−0"1’−0"5:125:125:125:125:125:121’−0"1’−0"1’−0"1’−0"R806.2:THE MINIMUM NET FREE VENTILATING AREA SHALLNOT BE LESS THAN 1/150 OF THE VENTED SPACE.EXCEPTION: THE MINIMUM NET FREE VENTILATION AREASHALL BE 1/300 OF THE VENTED SPACE PROVIDED NOTLESS THAN 40 PERCENT AND NOT MORE THAN 50PERCENT OF THE REQUIRED VENTILATING AREA ISPROVIDED BY VENTILATORS LOCATED IN THE UPPERPORTION OF THE ATTIC OR RAFTER SPACE. UPPERVENTILATORS SHALL BE LOCATED NOT MORE THAN 3FEET (914 MM) BELOW THE RIDGE OR HIGHEST POINT OFTHE SPACE, MEASURED VERTICALLY, WITH THE BALANCEOF THE REQUIRED VENTILATION PROVIDED BY EAVE ORCORNICE VENTS. WHERE THE LOCATION OF WALL ORROOF FRAMING MEMBERS CONFLICTS WITH THEINSTALLATION OF UPPER VENTILATORS, INSTALLATIONMORE THAN 3 FEET (914 MM) BELOW THE RIDGE ORHIGHEST POINT OF THE SPACE SHALL BE PERMITTED.ATTIC VENTILATION − AT FIRST FLOORSQ. FT. ATTICAREANET FREE AREASOFFIT VENTINGNET FREE AREAUPPER ROOF VENTINGVENTS REQUIRED48" TAMCO OFF−RIDGE VENT (138 SI NET FREE) − NOTE: LOCATE RIDGE VENTS 2'-0" OFF ALL HIPS RIDGES ORVALLEYS, MIN., TYP.TOTAL VENTING REQUIREDROOF PLANSCALE: 1/4"=1’−0"UNDERLAYMENT APPLICATIONS SHALL BE INSTALLED INACCORDANCE WITH SECTION R905, TABLE R905.1.1FOR ASPHALT SHINGLES REFERENCE TO SECTION R905.2FOR TILE ROOFING REFERENCE TO SECTION R905.3A3.1ROOF PLANK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______ CONCRETE FOOTINGSEE STRUCTURAL PLANSFIN. FLR.8’−8"T.O.M.T.O. WDW7’−4"A5.11A5.11125PRE−ENGINEERED ROOF TRUSSESSEE FRAMING SHEET FOR DETL’SROOF SHINGLES PER COMMUNITYSPECS. (TYP.)125R−4.1INSULATIONR−30 INSULATIONR−11INSULATIONFIN. FLR.8’−8"T.O.M.T.O. WDW7’−4"125PRE−ENGINEERED ROOF TRUSSESSEE FRAMING SHEET FOR DETL’SR−30 INSULATION125ROOF SHINGLES PER COMMUNITYSPECS. (TYP.)A5.12A5.12CONCRETE FOOTINGSEE STRUCTURAL PLANSR−4.1INSULATIONR−4.1INSULATIONK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______A5.1BUILDING SECTIONSBUILDING SECTIONSCALE: 1/4"=1’−0"BUILDING SECTIONSCALE: 1/4"=1’−0" PROVIDE 2X4FRAMEDENCLOSURE FORELECTRICALPANEL, FINISH W/12" GYPSUMBOARDELECTRICALPANELCONCRETECURB REFERTO PLANSELECTRICALPANELCONCRETECURB REFERTO PLANSGYPSUMBOARDGYPSUMBOARDGARAGE ELECTRICALPANEL IS TO BEINSTALLED ACCORDINGTO ALL APPLICABLELOCAL, STATE ANDNATIONAL CODES.VERIFY PANELDIMENSIONS PRIOR TOCONSTRUCTION.CONCRETESLAB ONGRADE ATGARAGEFLOORATTIC OR SECONDFLOOR LIVING SPACEREFER TO PLANS12" GYPSUMBOARDNICHE FORELECTRICALPANEL &WIRING2’−4"6’−2"2’−4"3’−2"6’−2"8"PER PLAN3"1’−0"3"1’−6"3 1/2"EXTERIORCMU BLOCKWALLEXTERIORCMU BLOCKWALLSTUCCOFINISHELECTRIC METERLOCATION − SEEPLANS. VERIFYINSTALLATION INFIELD3’−2"8"PER PLANT.O.MGRADEATTIC ORSECOND FLOORLIVING SPACEREFER TO PLANS3/4"4"K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______A5.2TYPICAL WALL SECTIONS FOLDFOLD @ 45°FOLD @ 77°WATERTIGHT SEAL.FOLD. BOTTOM FLANGE78" THICK, 3 COATCEMENT PLASTERWRAP LAYERS OF BUILDINGWRAP OVER NAILING FLANGE, STOPWRB 1−1/2" ABOVE SHINGLES5X5 WALL FLASHINGKICK−OUT FLASHING (SEE DTL. BELOW)SHINGLE ROOFINGFELT UNDERLAYMENTFASCIA WRAPDRIP EDGE: OVERLAP 3", EXTENDBELOW SHEATHING, MECH. FASTEN4" O.C. MAX.60 MIN. GRADE D PAPER BACKED LATHBARRICADE PLUS WRB (OR APPROVED EQUAL)6"6"6"EXTERIOR CMU WALL1) PROTECTO WRAP LWM200 ORSIMILAR ON WINDOW SILL, JAMBSAND HEAD. APPLY AROUNDCORNER AND EXTEND 6" ALLAROUND THE EDGES OF THE WALL2) SET P.T. WOOD BUCKOVER CMUWATERPROOFING INURETHANE SEALANT.FASTEN PER PRODUCTAPPROVALS.3) APPLY LIQUIDWATERPROOFINGMEMBRANE OVER THE TOPAND EXTERIOR FACE OFBUCK AND SILL4) INSTALL WINDOWOR DOOR. FASTEN PERPRODUCT APPROVALSAND SEAL WINDOW ORDOOR FRAME TO P.T.WOOD BUCK ANDMASONRYCMU OPENING WATERPROOFINGSCALE: N.T.S.SEAL EDGE OF P.T. WOODBUCK TO MASONRYPRECAST SILLWOOD SHEATHING60 MIN. GRADE D PAPER BACKED LATHOVER BARRICADE PLUS WRB (ORAPPROVED EQUAL)78" THICK, 3 COAT CEMENT PLASTERMETAL LATHLAP WRB & TAPE OVER 5X5 "L" TYPE CONTINUOUS GALV.METAL FLASHING (NAIL TO ROOF DECK,NOT WALL SHEATHING)CAP SHINGLE − DO NOT NAIL, INSTALLWITH ROOF CEMENTSHINGLE ROOFINGROOF CEMENTICE AND WATER SHIELD15" VERTICAL AND 15" DOWN ROOFK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______WP1WATERPROOFINGDETAILS4/16/20PLAN UPDATES 10’−0"P.C.ATTIC LIGHT2’−0"ELECTRICALPANEL ON2X4 WALLMP.B. FORCHIMESA/CDISCONNECT33ADD BLOCKINGAS REQUIREDADD BLOCKINGAS REQUIREDADD BLOCKINGAS REQUIRED3DISCONNECT333−BULBFIXTURE3ADD BLOCKINGAS REQUIREDVP3−BULBFIXTUREADD BLOCKINGAS REQUIREDRANGE3333ADD BLOCKINGAS REQUIRED3PREWIRE FORGARAGE DOOROPENER 3ADDBLOCKINGAS REQUIREDD/WUNDER−SINKSWITCH FORDISPOSALCLIRRIGATION TIMERLOCATION VARIES PERMAIN WATER SERVICECONNECTION 33FIELDVERIFYMETERCAT 5CAT 5STRUCTUREDWIRE PANEL(SWP) VERIFYLOCATION INFIELDW/D SPACEVPCAT 5LOCATE MICRO.OUTLET INUPPER CABS.WHDISCONNECT 33’−0"60" A.F.F. WITHSTRUCTURALBACKING FOR TVREF.DW4’−0"5’−10"ADD BLOCKINGAS REQUIREDWET BARSDSDSDSD33#3/0 AL, 1#6G 1 12" C150 A MLO PANEL42 CIRCUITS N1150 A METERCOMBO 120/240V1ph. N3R 22K AIC150A/2P#4 GROUND WIREBLDG STEEL2 GROUND ROD58"x8’ GALV.2" PVC STUBDOWN FORFLORIDAPOWER &LIGHTLELIALOAD CALCULATIONSPANEL "A"DESCRIPTION LOAD KVAGENERAL LTG. 3Wx1917 S.F.5751SMALL APPLIANCESMALL APPLIANCEREFRIGERATORDISHWASHERDISPOSALMICROWAVERANGEWATER HEATERDRYERWASHERLAUNDRYEXTERIOR GFIIRRIGATIONGDOTOTAL KVAAHU #1 HEATFIRST 10KWBALANCE @ 40%AC LOADTOTAL LOADKVA/240V150015001200240085012008000450050001500150015008009003810110000 KWx.65 65001000011240650027740116AMPSWIRE POLE TRIPDESCRIPTION CKTWIREPOLETRIPDESCRIPTIONCKT15379111315171921232527293135333739264810121614182022262428303236343840#10#6#12#12#12#12#12#12#12#12#12#12#12#6#10#10#12#14#14#14#14#14#142P2P1P1P1P1P1P1P1P1P1P1P1P30A60A20A20A20A20A20A20A20A20A20A20A20A2P50A2P2P25A30A20A 1P1P1P1P1P1P1P15A15A15A15A15A15ASPACE SPACESPACE SPACESPACE SPACESPACE SPACESPACE SPACESPACESPACEAIR COMPRESSORAIR HANDLERDISHWASHER (AF/GFI)DISPOSAL (AF/GFI)WASHER (AF/GFI)REFRIGERATOR (AF)SMALL APPLIANCE (AF/GFI)SMALL APPLIANCE (AF/GFI)BATH (GFI)GARAGE DR. OPENER (GFI)GARAGE (GFCI)SPRINKLER SOLENOIDEXTERIOR (GFI)RANGEWATER HEATERDRYERMICROWAVE (AF)GENERAL LTG. (AF)GENERAL LTG. (AF)GENERAL LTG. (AF)GENERAL LTG. (AF)GENERAL LTG. (AF)GENERAL LTG. (AF)E1.1FIRST FLOORELECTRICAL PLANK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______LOAD CALCULATIONSSCALE: N.T.S.PANEL SCHEDULESCALE: N.T.S.ELECT. RISER DIAGRAMSCALE: N.T.S.FIRST FLOOR ELECTRICAL PLANSCALE: 1/4"=1’−0" RANGEW/D SPACEHB.REF.DWCONDENSATELINE (V.I.F.)52’−8"50’−2"48’−1"51’−312"47’−712"37’−8"2’−334"10’−10"34’−3"32’−3"34’−912"36’−1112"39’−9"11’−1112"25’−1"15’−812"12’−4"7’−212"13’−10"6’−012"9’−512"7’−812"12’−9"53’−912"10’−7"LOCATION VARIESPER MAIN WATERSERVICECONNECTIONK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______SLAB PENETRATION PLANSCALE: 1/4"=1’−0"P1.1SLAB PENETRATION PLANPLUMBING RISER DIAGRAMSCALE: N.T.S.