Loading...
HomeMy WebLinkAboutREVISION,WS 15 - Rev 1 - Cover & A2.1, 9.10.20K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______THESE PLANS HAVE BEEN PREPARED TO MEET THE REQUIREMENTSOF THE FLORIDA BUILDING CODE, 6th Edition (2017) RESIDENTIALw/ APPLICABLE SUPPLEMENTSOCCUPANCY: R3BUILDING TYPE: VBSPRINKLED: NOFLOOD ZONE: ’X’TERMITE PROBABILITY: VERY HEAVYLOT015ABBREVIATIONSMASMATMAXMCMINM.O.MTLN.I.C.(NTS)OHGDOPEROPNGOPTOSBOZ1/R1/SPCPNLPLYWDPREFABPRPROJPSIPSFP.T.QUADREFREINFREQ’DRNGR.O.RRNDMASONRYMLMATERIALMAXIMUMMEDICINE CABINETMINIMUMMICRO LAMMASONRY OPENINGMETALNOT IN CONTRACTNOT TO SCALEOVERHEAD GARAGE DOOROPERATOROPENINGOPTIONALORIENTED STRAND BOARDOUNCEONE RODONE SHELFPRECASTPANELPLYWOODPREFABRICATEDPAIRPROJECTEDPOUNDS PER SQUARE INCHPOUNDS PRE SQUARE FOOTPRESSURE TREATEDQUADRUPLEREFRIGERATORREINFORCEDREQUIREDRANGEROUGH OPENINGRISERROUNDMECHMECHANICALMIRMIRRORABA.F.F.ADJ.ALUM.ANCH@BD.BLDG.BM.BLKGBRG.BRK.C.J.CMUCOL.CONC.COND.CONT.CANT.CLG.CMCRDdDBL.DIA.DIR.DNDRDWDWGD.S.DTLEA.E.J.ELEC.CLBFANCHOR BOLTABOVE FINISH FLOORADJUSTABLEALUMINUMANCHORANGLEATBOARDBI−FOLDBUILDINGBEAMBLOCKINGBEARINGBRICKCONTROL JOINTCENTER LINECONCRETE MASONRY UNITCOLUMNCONCRETECONDITIONCONTINUOUSCANTILEVERCEILINGCROWN MOLDINGCHAIR RAIL DRYERPENNYDOUBLEDIAMETERDIRECTIONDOWNDOORDISH WASHERDRAWINGDOWNSPOUTDETAILEACHEXPANSION JOINTELECTRICALB.O.BOTTOM OFO.C.ON CENTERPKTPOCKET DOOROBSOBSCUREDB.P.BI−PASS DOORPDSPULL−DOWN STAIRFDFND.FLR.FPFRFRMFTGGA.GALV.GCGENGYP.GLHGT.HDR.HBINSUL.INT.LTFLOOR DRAINFOUNDATIONFLOORFIREPLACEFIRE RATEDFRAMEFOOTINGGAUGEGALVANIZEDGENERAL CONTRACTORGENERALGYPSUMGLUE LAMHEIGHTHEADERHOSE BIBBINSULATIONINTERIORLAUNDRY TUBHCHOLLOW COREHORIZ.HORIZONTALFINISHED FLOORFIN.LAVATORYLAV.ELEVEQ.EQUIP.EXPEXT.EEELEVATIONEQUALEQUIPMENTEXPANSIONEXTERIOREACH ENDFXDFIXEDGLSGLASSHHIGHR&SSCSCHEMSHLFSHTSIMS.S.STLSTRUCTSUSPSGDSQTBT&GTYPTTRTRPLU.N.O.VERTV.L.I.F.WW/WDWWMWDWROD AND SHELFSOLID CORESCHEMATICSHELFSHEETSIMILARSTAINLESS STEELSTEELSTRUCTURALSUSPENSIONSLIDING GLASS DOORSQUARETOWEL BARTONGUE AND GROOVETYPICALTREADTOWEL RODTRIPLEUNLESS NOTED OTHERWISEVERTICALVERIFY LOCATION IN FIELDWASHERWITHWOODWELD WIRE MESHWINDOWWCWATER CLOSETSINGLE HUNGSHSHOWERSHWRTEMPTEMPEREDT.O.TOP OF RELEASE HISTORYTERMITE PROTECTION SHALL BE PROVIDED BY DOMINION2L TERMITICIDE/INSECTICIDE. UPON COMPLETION OF THEAPPLICATION OF THE TERMITE PROTECTIVE TREATMENT,A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THEBUILDING DEPARTMENT BY THE LICENSED PESTCONTROL COMPANY THAT CONTAINS THE FOLLOWINGSTATEMENT: "THE BUILDING HAS RECEIVED A COMPLETETREATMENT FOR THE PREVENTION OF SUBTERRANEANTERMITES. TREATMENT IS IN ACCORDANCE WITH RULESAND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENTOF AGRICULTURE AND CONSUMER SERVICES."90 Matawan RoadMatawan, NJ 07747(732) 383−2200TMFRONT & REAR ELEVATIONSFIRST FLOOR PLANCOVERSHEET & BUILDING DATAA2.1A1.1CS.1CS.2A2.2ROOF PLANA5.1 BUILDING SECTIONSA5.2 TYPICAL WALL SECTIONSGENERAL NOTESDRAWING INDEXFIRST FLOOR ELECTRICAL PLANE1.1SLAB PENETRATION PLANP1.1SIDE ELEVATIONSA3.1STRUCTURAL NOTESS−0.0F−1.0BLOCK PLANS−1.3 ROOF FRAMING PLANSD−1 FOUNDATION DETAILSSTRUCTURAL DETAILSSD−2SLAB PLANF−2.0STRUCTURAL DETAILSPBSB−1WP1WATERPROOFING DETAILSCS1COVER SHEET &BUILDING DATA1,616 SF"A"ELEVATION1ST FLR/TOTAL A/CENTRYTOTAL URLANAI35 SF87 SF2,118 SFGARAGE380 SF14,005 CU. FT.TOTAL VOLUME8/18/20UPDATED GARAGE & FRONT WINDOW TRIMS1 DOOR ENTRYTRIM DETAILSCALE: 3/4"=1’−0"1REAR ELEVATIONSCALE: 1/4"=1’−0"FRONT ELEVATIONSCALE: 1/4"=1’−0"NOTE: WRAP THE SAND FINISH TRIM BAND (WHERE SHOWNAROUND WINDOWS & DOORS) INTO THE JAMB, HEAD & SILLOF THE WINDOW & DOORS. PAINT THE BAND, JAMB, HEAD &SILL THE TRIM COLOR.PAINT COLOR SCHEMEBODY COLORTRIM COLORSAND FINISHMEDIUM TEXTURE /SKIP TROWEL FINISHSURFACE TEXTURE / FINISH KEYSTUCCO AND PORTLAND CEMENT PLASTER SHALLBE INSTALLED PER THE CURRENT ASTM C926 & C1063REQUIREMENTS & PROVISIONS OF THE FLORIDA BUILDING CODECONTROL JOINTS IN 3−COAT STUCCO SHALL BE USED TODELINEATE STUCCO AREAS NOT GREATER THAN 144 SQ. FT. ORAT A MAXIMUM DISTANCE OF 18’ BETWEEN JOINTSPER ASTM C1063 (CURRENT EDITION)WEEP SCREED SHALL BE INSTALLED AT STUCCO TRANSITIONS BETWEEN WOOD AND MASONRYAS REQUIRED BY ASTM C1063 (CURRENT EDITION)STUCCO SHALL NOT BE LESS THAN 3 COATS WHEN APPLIEDOVER METAL OR WIRE LATH AND SHALL NOT BELESS THAN 2 COATS WHEN APPLIED OVER MASONRYA2.1FRONT & REAR ELEVATIONSK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______11UPDATED GARAGE & FRONT108/18/20 WINDOW TRIMS