Loading...
HomeMy WebLinkAboutElectrical DrawingsVPVPVPVP $$GFCIGFCI$GFCILOCATION OF WORK GENERAL NOTES PIT - 1ST FLOOR ELECTRICAL MACHINE ROOM (ROOF) - ELECTRICAL DRAWINGS ARE PROVIDED TO REFERENCE LOCATIONS OF WORK SITES AND SURROUNDING AREAS. ALL MEASUREMENTS AND DISTANCES MUST BE VERIFIED AT THE WORK SITE. # NOTE CONSTRUCTION NOTES KEY PLAN G E N E R A L E L E C T R I C A L N O T E PLANS SUBMITTED FOR REVIEW AFTER DECEMBER 31, 2017 ARE DESIGNED IN ACCORDANCE WITH THE 2014 NATIONAL ELECTRICAL CODE. DRAWING SCALE PROJECT NO. DRAWING NO. SHEET OF DATEDRAWN BY T H I S D O C U M E N T C O N T A I N S I N F O R M A T I O N T H A T C A N N O T B E R E P R O D U C E D O R D I V U L G E D , I N W H O L E O R I N P A R T , W I T H O U T W R I T T E N A U T H O R I Z A T I O N F R O M N I C H O L S C O N T R A C T I N G , I N C . 3 0 1 -9 2 4 -5 2 5 8 FREDERICK NICHOLS - CGC1522915 GREGORY JOHN GRESETH - EC13009689 GREGORY JOHN GRESETH - CAC1820514 5 0 8 O L N E Y S A N D Y S P R I N G R O A D S U I T E #2 0 0 S A N D Y S P R I N G , M D 2 0 8 6 0 PHONE:3 0 1 -9 2 4 -5 2 5 8 FAX:3 0 1 -9 2 4 -5 2 4 5 W W W .N I C H O L S C O N T R A C T I N G .C O M NJLofrancoCONTRACT LICENSE INFORMA TIONSHEET C O N T E N T NO.BY REVISION DATE 1 2 3 2 13456 2 13456 C D B A C D B A ANSI E[pand C (11.00 X 17.00 Inches) OCCUPANCY CLASSIFICATION TYPE OF CONSTRUCTION NO. OF STORIES APPLICABLE BUILDING CODES OCCUPANCY CLASSIFICATION TYPE OF CONSTRUCTION NO. OF STORIES APPLICABLE BUILDING CODES TYPE I, II GENERAL NOTES 01-20-20141 7/9/2020 EMPRESS CONDOMINIUMS 1 OF 1 E1.1 1.DIRECT REPLACEMENT OF ELEVATOR CAB LIGHT POWER DISCONNECTS. 2.DIRECT REPLACEMENT OF ALL NECESSARY LOAD SIDE CONDUIT AND WIRE FROM THE MAIN LINE POWER AND CAB LIGHT DISCONNECTS TO THE NEW ELEVATOR CONTROLLERS. 3.DIRECT REPLACEMENT OF LIGHT FIXTURES IN THE ELEVATOR MACHINE ROOM. 4.DIRECT REPLACEMENT OF EXISTING NON-GFCI OUTLET WITH GFCI RECEPTACLE IN THE ELEVATOR MACHINE ROOM. 5.DIRECT REPLACEMENT OF LIGHT FIXTURES IN THE ELEVATOR PITS. 6.DIRECT REPLACEMENT OF EXISTING NON-GFCI OUTLET WITH GFCI RECEPTACLE IN THE ELEVATOR PITS. ML - 3 # 1/0 THHN + 6G in 1 1 2" C CL - 2 # 12 THHN + 12G in 1/2" C HOISTWAY 9600 S. Ocean Dr Jensen Beach, FL 34957 SCALE E1.2 MACHINE ROOM (ROOF) - ELECTRICAL 3/8" = 1'Feet 0 2 4 Empress Condominiums 9600 S. Ocean Dr Jensen Beach, FL 34957 ELEVATOR MACHINE FBC, NFPA 101, NFPA 70 14 STOREY BLDG. BUSINESS GROUP 1.NO FIRE ALARM WORK IS PERFORMED UNDER THIS PERMIT. 2.NO STRUCTURAL WORK, DESIGN CHANGES, OR ADDITIONS ARE PERFORMED UNDER THIS PERMIT THEREFORE ARCHITECTURAL DRAWINGS ARE NOT PROVIDED OR REQUIRED. a.ALL NEW WORK AND EXISTING CONSTRUCTION ARE CLEARLY IDENTIFY. DRAWINGS ARE OF SUFFICIENT CLARITY AND QUALITY TO EFFECTIVELY CONVEY THE NATURE AND SCOPE OF THE PROPOSED WORK. b.THE CLASS OF REHAB IS “RENOVATION” PER CHAPTER 43, SECTION 43.4… “THE REPLACEMENT IN KIND, STRENGTHENING OR UPGRADING OF BUILDING ELEMENTS, MATERIALS, EQUIPMENT OR FIXTURES THAT DOES NOT RESULT IN THE RECONFIGURATION OF THE BUILDING SPACES WITHIN”. c.WORK UNDER THIS PERMIT MEETS THE DEFINITION FROM FBC, EXISTING AS “ALTERATION - LEVEL 1” AND IS COVERED BY THE PROVISIONS OF CHAPTER 7. IAW CHAPTER 7, THE “ALTERATIONS” MADE BY THIS PERMIT MEET THE STANDARDS OF CONFORMANCE FOR ALL AREA WORK. 3.NO NEW DESIGN FEATURES OR ENGINEERING CHANGES ARE MADE UNDER THIS PERMIT. ELECTRICAL DRAWING IS BASED SOLELY ON THE SCOPE OF THE WORK TO BE PERFORMED; ALL WORK IS DIRECT REPLACEMENT OF EXISTING COMPONENTS. 4.ELECTRICAL CIRCUITS FOR THE ELEVATOR CAB LIGHTING, PIT LIGHTING, MACHINE ROOM (MR) LIGHTING AND MR GFCI CIRCUITS ARE ALL PRE-EXISTING CIRCUITS VERIFIED TO BE POWERED FROM SEPARATE SOURCES. REPLACEMENT OF THESE COMPONENTS AND FIXTURE ARE ALL DIRECT REPLACEMENT OF EXISTING EQUIPMENT; NO NEW CIRCUITS ADDED IN THIS PROJECT. MACHINE ROOM 2 2 3/8" = 1' MLCL 1 SCALE E1.1 PIT - 1ST FLOOR ELECTRICAL 3/8" = 1' Feet 0 2 4 2 1 ML CL ELEV PANEL CONTROLLER CONTROLLER 3 3 3 3 3 3 4 4 4 44 5 5 ELEVATOR MACHINE MACHINE ROOM (ROOF) L O B B Y AC UNIT (RETAIN) (RETAIN)(RETAIN) PIT PIT