$$GFCIGFCI$GFCILOCATION OF WORK
GENERAL NOTES
PIT - 1ST FLOOR ELECTRICAL
MACHINE ROOM (ROOF) - ELECTRICAL
DRAWINGS ARE PROVIDED TO
REFERENCE LOCATIONS OF WORK
SITES AND SURROUNDING AREAS. ALL
MEASUREMENTS AND DISTANCES
MUST BE VERIFIED AT THE WORK SITE.
#
NOTE
CONSTRUCTION NOTES
KEY PLAN
G E N E R A L E L E C T R I C A L N O T E
PLANS SUBMITTED FOR REVIEW
AFTER DECEMBER 31, 2017 ARE
DESIGNED IN ACCORDANCE WITH
THE 2014 NATIONAL ELECTRICAL
CODE.
DRAWING SCALE
PROJECT NO.
DRAWING NO.
SHEET OF
DATEDRAWN BY
T H I S D O C U M E N T C O N T A I N S
I N F O R M A T I O N T H A T C A N N O T B E
R E P R O D U C E D O R D I V U L G E D , I N
W H O L E O R I N P A R T , W I T H O U T
W R I T T E N A U T H O R I Z A T I O N F R O M
N I C H O L S C O N T R A C T I N G , I N C .
3 0 1 -9 2 4 -5 2 5 8
FREDERICK NICHOLS - CGC1522915
GREGORY JOHN GRESETH - EC13009689
GREGORY JOHN GRESETH - CAC1820514
5 0 8 O L N E Y S A N D Y S P R I N G R O A D
S U I T E #2 0 0
S A N D Y S P R I N G , M D 2 0 8 6 0
PHONE:3 0 1 -9 2 4 -5 2 5 8
FAX:3 0 1 -9 2 4 -5 2 4 5
W W W .N I C H O L S C O N T R A C T I N G .C O M
NJLofrancoCONTRACT LICENSE INFORMA TIONSHEET C O N T E N T
NO.BY REVISION DATE
1
2
3
2 13456
2 13456
C
D
B
A
C
D
B
A
ANSI E[pand C (11.00 X 17.00 Inches)
OCCUPANCY CLASSIFICATION
TYPE OF CONSTRUCTION
NO. OF STORIES
APPLICABLE BUILDING CODES
OCCUPANCY CLASSIFICATION
TYPE OF CONSTRUCTION
NO. OF STORIES
APPLICABLE BUILDING CODES
TYPE I, II
GENERAL NOTES
01-20-20141 7/9/2020
EMPRESS CONDOMINIUMS
1 OF 1
E1.1
1.DIRECT REPLACEMENT OF ELEVATOR
CAB LIGHT POWER DISCONNECTS.
2.DIRECT REPLACEMENT OF ALL
NECESSARY LOAD SIDE CONDUIT
AND WIRE FROM THE MAIN LINE
POWER AND CAB LIGHT
DISCONNECTS TO THE NEW
ELEVATOR CONTROLLERS.
3.DIRECT REPLACEMENT OF LIGHT
FIXTURES IN THE ELEVATOR MACHINE
ROOM.
4.DIRECT REPLACEMENT OF EXISTING
NON-GFCI OUTLET WITH GFCI
RECEPTACLE IN THE ELEVATOR
MACHINE ROOM.
5.DIRECT REPLACEMENT OF LIGHT
FIXTURES IN THE ELEVATOR PITS.
6.DIRECT REPLACEMENT OF EXISTING
NON-GFCI OUTLET WITH GFCI
RECEPTACLE IN THE ELEVATOR PITS.
ML - 3 # 1/0 THHN + 6G in 1 1
2" C
CL - 2 # 12 THHN + 12G in 1/2" C
HOISTWAY
9600 S. Ocean Dr
Jensen Beach, FL 34957
SCALE
E1.2 MACHINE ROOM (ROOF) - ELECTRICAL
3/8" = 1'Feet
0 2 4
Empress Condominiums
9600 S. Ocean Dr
Jensen Beach, FL 34957
ELEVATOR
MACHINE
FBC, NFPA 101, NFPA 70
14 STOREY BLDG.
BUSINESS GROUP
1.NO FIRE ALARM WORK IS PERFORMED UNDER THIS PERMIT.
2.NO STRUCTURAL WORK, DESIGN CHANGES, OR ADDITIONS ARE PERFORMED UNDER THIS
PERMIT THEREFORE ARCHITECTURAL DRAWINGS ARE NOT PROVIDED OR REQUIRED.
a.ALL NEW WORK AND EXISTING CONSTRUCTION ARE CLEARLY IDENTIFY. DRAWINGS
ARE OF SUFFICIENT CLARITY AND QUALITY TO EFFECTIVELY CONVEY THE NATURE AND
SCOPE OF THE PROPOSED WORK.
b.THE CLASS OF REHAB IS “RENOVATION” PER CHAPTER 43, SECTION 43.4… “THE
REPLACEMENT IN KIND, STRENGTHENING OR UPGRADING OF BUILDING ELEMENTS,
MATERIALS, EQUIPMENT OR FIXTURES THAT DOES NOT RESULT IN THE
RECONFIGURATION OF THE BUILDING SPACES WITHIN”.
c.WORK UNDER THIS PERMIT MEETS THE DEFINITION FROM FBC, EXISTING AS
“ALTERATION - LEVEL 1” AND IS COVERED BY THE PROVISIONS OF CHAPTER 7. IAW
CHAPTER 7, THE “ALTERATIONS” MADE BY THIS PERMIT MEET THE STANDARDS OF
CONFORMANCE FOR ALL AREA WORK.
3.NO NEW DESIGN FEATURES OR ENGINEERING CHANGES ARE MADE UNDER THIS PERMIT.
ELECTRICAL DRAWING IS BASED SOLELY ON THE SCOPE OF THE WORK TO BE PERFORMED;
ALL WORK IS DIRECT REPLACEMENT OF EXISTING COMPONENTS.
4.ELECTRICAL CIRCUITS FOR THE ELEVATOR CAB LIGHTING, PIT LIGHTING, MACHINE ROOM
(MR) LIGHTING AND MR GFCI CIRCUITS ARE ALL PRE-EXISTING CIRCUITS VERIFIED TO BE
POWERED FROM SEPARATE SOURCES. REPLACEMENT OF THESE COMPONENTS AND
FIXTURE ARE ALL DIRECT REPLACEMENT OF EXISTING EQUIPMENT; NO NEW CIRCUITS
ADDED IN THIS PROJECT.
MACHINE ROOM
2
2
3/8" = 1'
MLCL
1
SCALE
E1.1 PIT - 1ST FLOOR ELECTRICAL
3/8" = 1'
Feet
0 2 4
2
1
ML CL
ELEV
PANEL
CONTROLLER CONTROLLER
3
3
3
3
3
3
4
4 4 44
5 5
ELEVATOR
MACHINE
MACHINE ROOM (ROOF)
L O B B Y
AC
UNIT
(RETAIN)
(RETAIN)(RETAIN)
PIT PIT