HomeMy WebLinkAboutENGCALCS - ByersFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: HOMECRETE -BYERS
Builder Name: HOMECRETE
Street: 8682 LONESOME PINE TRAIL
Permit Office:
City, State, Zip: FORT PIERCE. FL,
Permit Number:
Owner: BYERS RES.
Jurisoiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1464.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=6.5 1296.00 ft'
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent.
R=11.0 168.00 ft'
c. N/A
R= ft'
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1852.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1852.00 ft2
6. Conditioned floor area above grade (ft2) 1852
b. N/A
R= ft2
Conditioned floor area below grade (ft) 0
0' N/A
R= ft.
7. Windows(189.0 sgft.) Description Area
11, Duds R ft2
a. Sup: Attic, Ret: LAUNDRY, AH: LAUNDRY 6 250
a. U -Factor. Dbl, U=0.29 101.00 ft2
SHGC: SHGC=0.29
b. U -Factor. Dbl, U=0.29 48.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.26
a. Central Unit
33.0 SEER:14.00
c. U -Factor: ON, U=0.32 40.00 ft2
SHGC: SHGC=0.26
13. Heating systems
kBtulhr Efficiency
d. U -Factor: NIA ft2
a. Electric Heat Pump
33.8 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 5.077 ft.
Area Weighted Average SHGC: 0.276
14. Hot water systems
8. Floor Types (1852.0 sgft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1852.00 R2
b. Conservation features
EF: 0.950
b. N/A R= ft2
None
c. N/A R= R2
15. Credits
Pstat
Glass/Floor Area: 0.102 Total Proposed Modified Loads: 54.03
PASS
Total Baseline Loads: 57.85
I hereby certify that the plans and specifications covered by
Review of the plans and
THE ST4I�
this calculation are in compliance with the lorida Energy
specifications covered by this
OF
ti a : , p
Code.
calculation indi tes compliance
y` ,r„"'` -" s
with the Florida Ergy Code.
•yi=�':�';,�`
PREPARED BY:
Before construction is completed
DATE:
this building will be inspected for
y
compliance with Section 553.908
I hereby certify that this ll In sig d, is in compliance
Florida Statutes.
✓� ��
with the Florida Energy
COp WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE-
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
8/31/2020 4:15 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: HOMECRETE - BYERS
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area. 1852
Lot #
Owner Name: BYERS RES.
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name: HOMECRETE
Rotate Angle: 0
Street:
8682 LONESOME PIN
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FORT PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
V/
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location TMY Site
97.5%
2.6%
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name Area
Volume
1 Entire House 1852
14816
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
InfiilID
Finished Cooled
Heated
1 BEDROOM 2 173
1384 No
1
3
1
No
Yes
Yes
2 BATH 2 60
480 No
0
1
No
Yes
Yes
3 BED 2 166
1344 No
1
1
No
Yee
Yes
4 DINING ROOM 324
2592 No
0
1
No
Yes
Yes
5 GREAT ROOM 289
2312 No
2
1
No
Yes
Yes
6 PANTRY 44
352 No
0
1
No
Yes
Yes
7 KITCHEN 150
1200 No
0
1
No
Yes
Yes
8 LAUNDRY 70
560 No
0
1
No
Yes
Yes
9 MASTER TOILET 26
208 No
0
1
No
Yes
Yes
10 MASTER BATH 144
1152 No
0
1
No
Yes
Yes
11 WIC MASTER INT 48
384 No
0
1
No
Yes
Yes
12 WIC MASTER EXT 48
384 No
0
1
No
Yes
Yes
13 MASTER SUITE 308
2466 No
2
1
No
Yes
Yes
FLOORS
# Floor Type Space
Perimeter Perimeter R -Value
Area
Joist R -Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio BEDROOM 2 26 ft
172.8 ft'
___
0 1
0
2 Slab -On -Grade Edge Insulatio BATH
2 Brit
60 ft'
___
1 0
0
3 Slab -On -Grade Edge Insulatio BED
2 26 ft
168 fta
1
0
4 Slab -On -Grade Edge Insulatio DINING ROOM 17 ft
324 fta
0 1
0
8/31/2020 417 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT RI IMMAI7V ruGrlrl Icr oeonor
8/31/2020 4:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
-
- -- .......v. ..ter vr.r
FLOORS
# Floor Type
Space Perimeter Perimeter R -Value
Area
Joist R -Value
Tile
Wood Carpet
5 Slab -On -Grade Edge Insulatio
GREAT ROOM 16 ft
289 ft'
1
0
0
6 Slab -On -Grade Edge Insulatio
PANTRY 19 ft
44 ft=
____
1
0
0
7 Slab -On -Grade Edge Insulatio
KITCHEN 1 ft
150 ft'
__
1
0
0
8 Slab -On -Grade Edge Insulatio
LAUNDRY 7 ft
70 ft'
___
1
0
0
9 Slab -On -Grade Edge Insulatio
MASTER TOILET 4 ft
26 fP
0
1
0
10SIab-On-Grade Edge Insulatio
MASTER BATH 23.5 ft
144 It'
__
1
0
0
11SIab-On-Grade Edge Insulatio
WIC MASTER IN 1 ft
48 ft'
____
0
1
0
_
12SIab-On-Grade Edge Insulatio
WIC MASTER EX S ft
48 ft'
0
1
0
13SIab-On-Grade Edge Insulatio
MASTER SUITE 30 ft
308.2 ft'
__
0
1
0
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip Composition shingles 2006 ft'
0 ft'
Medium
N
0.9
No 0.9
No 0
22.6
ATTIC
/
V
# Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
1852 ft'
N
N
CEILING
# Ceiling Type
Space
R -Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented)
BEDROOM 2
30
Blown
173 ft'
0.1
Wood
2 Under Attic (Vented)
BATH 2
30
Blown
60 ft'
0.1
Wood
_
3 Under Attic (Vented)
BED 2
30
Blown
168 IF
0.1
Wood
4 Under Attic (Vented)
DINING ROOM
30
Blown
324 ft'
0.1
Wood
5 Under Attic (Vented)
GREAT ROOM
30
Blown
289 ft'
0.1
Wood
6 Under Attic (Vented)
PANTRY
30
Blown
44 ft'
0.1
Wood
7 Under Attic (Vented)
KITCHEN
30
Blown
150 ft'
0.1
Wood
8 Under Attic (Vented)
LAUNDRY
30
Blown
70 ft'
0.1
Wood
9 Under Attic (Vented)
MASTER TOILET
30
Blown
26 ft'
0.1
Wood
10 Under Attic (Vented)
MASTER BATH
30
Blown
144 ft'
0.1
Wood
11 Under Attic (Vented)
WIC MASTER IN
30
Blown
48 ft'
0.1
Wood
_
12 Under Attic (Vented)
WIC MASTER EX
30
Blown
48 ft'
0.1
Wood
13 Under Attic (Vented)
MASTER SUITE
30
Blown
308 ft'
0.1
Wood
8/31/2020 4:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT StIMMORY rFlFrtfl IST l2l=Dn0T
8/31/20204:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
WALLS
Adjacent Space
Cavity Width
Height
Sheathing Framing
Solar
Below
0
1
E
Exterior
Concrete Block - Int InsBEDROOM 2
6.5 12
0 8
0
96.0 ft'
0
0
0.5
0
2
S
Exterior
Concrete Block - int InsBEDROOM 2
6.5 14
0 8
0
112.0 W
0
0
0.5
0
3
E
Exterior
Concrete Block - Int Insul BATH 2
6.5 6
0 8
0
48.0. ft'
0
0
0.5
0
_ 4
N
Exterior
Concrete Block - Int Insul BED 2
6.5 14
0 8
0
112.0 ft'
0
0
0.5
0
5
E
Exterior
Concrete Block - Int Insul BED 2
6.5 12
0 8
0
96.0 ft'
0
0
0.5
0
6
S
Exterior
Concrete Block - Int InSBIINING ROO
6.5 18
0 8
0
144.0 ft'
0
0
0.5
0
7
N
Exterior
Concrete Block - Int In801REAT ROO
6.5 17
0 8
0
136.0 ft'
0
0
0.5
0
8
N
Exterior
Concrete Block - Int Insul PANTRY
6.5 10
0 8
0
80.011'
0
0
0.5
0
9
E
Exterior
Concrete Block - Int Insul PANTRY
6.5 8
0 8
0
64.0 ft-
0
0
0.5
0
10
W
Exterior
Concrete Block - Int InsMASTER BA
6.5 13
0 8
0
104.0 ft'
0
0
0.5
0
_11
W
Exterior
Concrete Block - Int InsWIC MASTE
6.5 8
0 8
0
64.0 ft'
0
0
0.5
0
12
N
Exterior
Concrete Block- Int InsMASTER SUI
6.5 14
0 8
0
112.0 ft'
0
0
0.5
0
13
W
Exterior
Concrete Block - Int InsMASTER SUI
6.5 16
0 8
0
128.0 ft-
0
0
0.5
0
14
S
Garage
Frame - Wood MASTER BA
11 21
8
168.0 ft-
0.23
0.75
0
DOORS
#
Omt
Door Type Space
Storms
U -Value
Width
Height
Area
Ft
In
Ft In
1
S
Insulated DINING ROO
None
.46
3
6 8
20 ft'
2
S
Wood MASTER BA
None
.46
2
8
6 8
17.8 ft'
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC U -Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
S 2
Vinyl Low -E Double Yes
0.29 0.26
N
16.0 ft=
1 ft 6 in
1110 in
None
None
2
E 3
Vinyl Low -E Double Yes
0.29 0.29
N
9.0 ft'
1 ft 6 in
1 It 0 In
None
None
3
E 5
Vinyl Low -E Double Yes
0.29 0.29
N
16.0 ft'
1 It 6 In
1 ft 0 in
None
None
4
S 6
Vinyl Low -E Double Yes
0.29 0.26
N
32.0 fN
7 It 0 In
1 ft 0 in
None
None
5
N 7
Metal Low -E Double Yes
0.32 0.26
N
40.0 ft'
14 ft 0 in
1 ft 0 in
None
None
6
W 10
Vinyl Low -E Double Yes
0.29 0.29
N
12.0 ft'
1 ft 6 in
1 It 0 in
None
None
7
N 12
Vinyl Low•E Double Yes
0.29 0.29
N
32.0 ft'
1 ft 6 in
1 ft 0 In
None
None
8
W 13
Vinyl Low -E Double Yes
0.29 0.29
N
16.0 ft'
1 It 6 in
1 ft 0 in
None
None
_
9
W 13
Vinyl Low -E Double Yes
0.29 0.29
N
16.0 ft'
1 ft 6 in
1 It 0 in
None
None
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
469 ft' 469 ft'
64 ft
8 ft
1
8/31/20204:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPI IT SU IMMARV r wl=r-tei ic-r oconoT
8/31/2020 4:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
INFILTRATION
# Scope Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000356 1728.8 94.91 178.49 .1233 7
HEATING SYSTEM
# System Type
Subtype Efficiency Capacity Block
Ducts
1 Electric Heat Pump/
Split HSPF:8.2 33.8 kBtu/hr 1
sys#1
COOLING SYSTEM
# System Type
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split SEER: 14 33 kStu/hr cfm 0.76 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location EF Cap Use SetPnt Conservation
1 Electric None
Garage 0.95 50 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
V FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft=
DUCTS
/ ---- Supply —
V # Location R -Value Area
-- Return --- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT ON RLF
HVAC #
Heat Cool
1 Attic 6 250 ft'
LAUNDRY 1 ft' Default Leakage LAUNDRY (Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Coolin (]]Jan [[ ]]Feb Mar
Heating EX) Jan [X) Feb Marl
Venting 11 ]] Jan l[ l] Feb X Mar
Ceiling Fans:
jj] A r rr Ma X Jun X] Jul [X Au [[X7] Se �]J Oct ([[tXx]] Nov
Apr [. May Jun 4 ]Jul [ Aug t J SBP txl Oct lxl Nov
lel Jun [) Jul [ Aug ll Sep
fr Dec
[ Dec
8/31/2020 4:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017 INPUT SUMMARY CHFrW ICT RFanOT
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80 80
80
s0
PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68 68
68
ss
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 lbs/sq.ft.
0 ft2
0 ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
BED 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
DINING ROOM
Default(8 lbs/sq.ft.
ft2
ft
0.3
GREAT ROOM
Default(8 lbs/sq.ft.
ft2
ft
0.3
PANTRY
Default(8 lbs/sq.ft.
ft.
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft2
4
0.3
LAUNDRY
Default(8 lbs/sq.ft,
ft2
ft
0.3
MASTER TOILET
Default(6 lbs/sq.ft.
ft2
ft
0.3
MASTER BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC MASTER INT
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC MASTER EXT
Default(8 lbs/sq.ft.
ft2
ft
0.3
MASTER SUITE
8/31/2020 4:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* a 93
The lower the Energy Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location LAUNDRY
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4, 3
13. Cooling system: Capacity
33.0
a) Split system SEER
14.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1852
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.296
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.276
14. Heating system: Capacity33.8
c) Area
7c.-1 89.0
a) Split system heat pump HSPF
8.2
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
Sa. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
Sb. NA
e) Gas furnace, LPG AFUE
0 Other
9. Floor type, insulation level:
a) Slab -on -grade (R -value)
9a. 0.0
b) Wood, raised (R -value)
9b.
15. Water heating system
c) Concrete, raised (R -value)
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R -value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R -value)
10A2. 6.5
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R -value)
10B1. 11.
2. Masonry (Insulation R -value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a. 30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
0 Programmable thermostat
Yes
`Label required by Section R303.1.3 of the Florida Building Code, Energy
Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features wirnwitIl be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card willlet d based on installed code compliant features.
Builder Signature: Date:
Address of New Home: 8682 LONESOME PINE TRAIL City/F!-Zip: FORT PIERCE, FL
8131/2020 4:17:19 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of i