HomeMy WebLinkAboutCONTE PERMIT APP6 GENERAL 20/22 kW Specifications Generator Model G007038-1,G007039-1 G007042-2,G007043-2 G007038-3,G007039-3 G007042-3,G007043-3 (20 kW) (22 kW) (20 kW) (22 kW) Rated maximum continuous power capacity(LP) 20,000 Watts' 22,000 Watts. 20,000 Watts' 22,000 Watts' 18,000 Watts" 19,500 Watts" 16,000 Watts' 19.500 Watts" Rated maximum continuous power capacity(NG) 240 Rated voltage Rated maximum continuous load current—240 volts(LP/NG) 83.3175.0 91.7/St.3 83.3/75.0 91.7% 1.Less than 5% Total Harmonic Distortion 90 am 100 amp 90 amp 100 amp Main line circuit breaker p 1 Phase 2 Number of rotor poles 50 Hz Rated AC frequency 1.0 Power factor Battery requirement(not included) 12 Volts,Group 26R 540 GCA minimum or Group 35AGM 650 CCA minimum 448/203 466/211 436/198 445/202 Unit weight(Ib/kg) 48 x 25 x 29/121.9 x 63.5 x 73.7 Dimensions(L x W x H)in/cm Sound output In 08(A)at 23 It(7 m)with generator operating at normal load" 67 5 57 7 67 7 55 57 Sound output in dB(A)at 231t(7 m)with generator in Quiet-Test"low-speed exercise mode— 55 5 min Exercise duration Engine GENERAC G-Force 1000 Series Engine type 2 Number of cylinders 999 cc Displacement Aluminum w/cast iron sleeve Cylinder block Overhead valve Valve arrangement Solid-state w/magneto Ignition system Electronic Governor system 9.5:1 Compression ratio 12 VDC Staitei Approx,1 Oil capacity including titter 0/1.8 L 3.600 Operating rpm Fuel consumption Natural gas ft3/hr(m3/hr) 204(5.78) 228(6.46) 164(4.64) 203(5.75) 1/2 Load 301(8.52) 327(9.26) 287(6.13) 306(8.66) Full Load Liquid propane ft3/hr(gal/hr)[L/hr1 87(2.37)t8.991 92(2.53)t9.571 86(2,36)t8.951 92(2.53)(9,571 1/2 Load 130(3.56)[13.481 142(3.90)(14.771 136(3.74)[14.15] 142(3.90)[14.771 Full Load Note.Fuel pipe must be sized for full load.Required luel pressure to generator fuel Inlet at all load ranges-3.5--7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP gas. For BTU content.multiply fta/hr x 2500(LP)or ft3/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls Two-line plain tent multilingual LCD Simple user Interface for ease of operation. Mode buttons:AUTO Automatic start on utility failure.Weekly,Bi-weekly,or Monthly selectable exerciser. MANUAL Start with starter control,unit stays on.v utility falls.transfer to load takes place. Stops unit.Power is removed.Control and charger still operate. OFF Standard Ready to Run/Maintenance messages Standard Engine run hours indication Standard(programmable by dealer only) Programmable start delay between 2-1500 seconds Standard Utility Voltage Loss/Return to Utility adjustable(brownout setting) From 140 S V/190-216 V Future Set Capable Exerciser/Exercise Set Error warning Sta 50 events each RUn/Alarn,VMalntenance logs Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration)_ Starter lock-out Starter cannot re-engage until 5 sec after engine has stopped. Standard Smart Battery Charger Standard Charger Fault/Missing AC warning Low Battery/Battery Problem Protection and Battery Condition indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Standard Under-Frequency/Overload/Stepper Overcurrent Protection Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard Standard High Engine Temperature Shutdown Standard Internal Faull/Inconect Wiring protection Standard Common external fault capability Standard Field upgradable firmware "Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby.Applicable for supplying emergency power for the duration of the utility power outage.No overload capability is available for this rating.(All ratings in accordance with BS5514,IS03046 and DIN6271).,Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,0001t(304.8 m)above sea level,and also will decrease approximately 1%for each 10°F(6°C)above 60°F(16°C).