20/22 kW Specifications
Generator
Model G007038-1,G007039-1 G007042-2,G007043-2 G007038-3,G007039-3 G007042-3,G007043-3
(20 kW) (22 kW) (20 kW) (22 kW)
Rated maximum continuous power capacity(LP) 20,000 Watts' 22,000 Watts. 20,000 Watts' 22,000 Watts'
18,000 Watts" 19,500 Watts" 16,000 Watts' 19.500 Watts"
Rated maximum continuous power capacity(NG) 240
Rated voltage
Rated maximum continuous load current—240 volts(LP/NG) 83.3175.0 91.7/St.3 83.3/75.0 91.7% 1.Less than 5%
Total Harmonic Distortion 90 am 100 amp 90 amp 100 amp
Main line circuit breaker p
1
Phase 2
Number of rotor poles 50 Hz
Rated AC frequency 1.0
Power factor
Battery requirement(not included) 12 Volts,Group 26R 540 GCA minimum or Group 35AGM 650 CCA minimum
448/203 466/211 436/198 445/202
Unit weight(Ib/kg) 48 x 25 x 29/121.9 x 63.5 x 73.7
Dimensions(L x W x H)in/cm
Sound output In 08(A)at 23 It(7 m)with generator operating at normal load" 67 5 57 7 67 7
55 57
Sound output in dB(A)at 231t(7 m)with generator in Quiet-Test"low-speed exercise mode— 55 5 min
Exercise duration
Engine GENERAC G-Force 1000 Series
Engine type 2
Number of cylinders 999 cc
Displacement Aluminum w/cast iron sleeve
Cylinder block Overhead valve
Valve arrangement
Solid-state w/magneto
Ignition system Electronic
Governor system
9.5:1
Compression ratio 12 VDC
Staitei
Approx,1
Oil capacity including titter 0/1.8 L
3.600
Operating rpm
Fuel consumption
Natural gas ft3/hr(m3/hr) 204(5.78) 228(6.46) 164(4.64) 203(5.75)
1/2 Load 301(8.52) 327(9.26) 287(6.13) 306(8.66)
Full Load
Liquid propane ft3/hr(gal/hr)[L/hr1 87(2.37)t8.991 92(2.53)t9.571 86(2,36)t8.951 92(2.53)(9,571
1/2 Load 130(3.56)[13.481 142(3.90)(14.771 136(3.74)[14.15] 142(3.90)[14.771
Full Load
Note.Fuel pipe must be sized for full load.Required luel pressure to generator fuel Inlet at all load ranges-3.5--7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP gas.
For BTU content.multiply fta/hr x 2500(LP)or ft3/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG).
Controls
Two-line plain tent multilingual LCD Simple user Interface for ease of operation.
Mode buttons:AUTO Automatic start on utility failure.Weekly,Bi-weekly,or Monthly selectable exerciser.
MANUAL Start with starter control,unit stays on.v utility falls.transfer to load takes place.
Stops unit.Power is removed.Control and charger still operate.
OFF
Standard
Ready to Run/Maintenance messages
Standard
Engine run hours indication
Standard(programmable by dealer only)
Programmable start delay between 2-1500 seconds
Standard
Utility Voltage Loss/Return to Utility adjustable(brownout setting) From 140 S V/190-216 V
Future Set Capable Exerciser/Exercise Set Error warning Sta
50 events each
RUn/Alarn,VMalntenance logs
Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration)_
Starter lock-out Starter cannot re-engage until 5 sec after engine has stopped.
Standard
Smart Battery Charger
Standard
Charger Fault/Missing AC warning
Low Battery/Battery Problem Protection and Battery Condition indication Standard
Automatic Voltage Regulation with Over and Under Voltage Protection Standard
Standard
Under-Frequency/Overload/Stepper Overcurrent Protection
Safety Fused/Fuse Problem Protection Standard
Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard
Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard
Standard
High Engine Temperature Shutdown
Standard
Internal Faull/Inconect Wiring protection
Standard
Common external fault capability
Standard
Field upgradable firmware
"Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby.Applicable for supplying
emergency power for the duration of the utility power outage.No overload capability is available for this rating.(All ratings in accordance with BS5514,IS03046 and DIN6271).,Maximum kilovolt amps and current are
subject to and limited by such factors as fuel BTU/megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,0001t(304.8 m)above sea
level,and also will decrease approximately 1%for each 10°F(6°C)above 60°F(16°C).