Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBRI INVESTMENTS SPECS
421 71 6240 05 2/13/19Specifications subject to change without notice. EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R−410A REFRIGERANT 1−1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1−phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Filter−Drier supplied with every unit for field installation Copper tube / aluminum fin coil EASY TO INSTALL AND SERVICE Easy Access service valves on all models External high and low refrigerant service ports Only two screws to access control panel Factory charged with R−410A refrigerant BUILT TO LAST Baked−on powder coat finish over galvanized steel Post−painted (black) coil fins Coated, weather−resistant cabinet screws Coated inlet grille with 3/8” (10mm) grille spacing for extra protection (hail guard) LIMITED WARRANTY* 10 year parts limited warranty (including compressor and coil) with timely registration 5 year parts limited warranty if not registered within 90 days of original installation *For owner occupied, residential applications only. Seewarranty certificate for complete details and restrictions, including warranty coverage for otherapplications. Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org . ModelNumber Size(tons)NominalBTU/hr Min. CircuitAmpacity Max. Fuseor Breaker Operating Dimensionswidth x depth x height in. (mm)Ship / OperatingWeight lbs. (kg) NXA418GKC 1−1/2 18,000 11.7 20 23−1/8 x 23−1/8 x 24−13/16(587 x 587 x 630)134/123 (61/56) NXA424GKC 2 24,000 14.1 20 25−3/4 x 25−3/4 x 25(654 x 654 x 635)140/119 (84/54) NXA430GKC 2−1/2 30,000 16.8 25 31−3/16 x 31−3/16 x 31−13/16(792 x 792 x 808)186/151 (84/68) NXA436GKC 3 36,000 18.1 30 31−3/16 x 31−3/16 x 24−13/16(792 x 792 x 630)151/134 (68/87) NXA442GKC 3−1/2 42,000 22.3 35 31−3/16 x 31−3/16 x 39−1/8(792 x 792 x 994)232/192 (105/87) NXA448GKC 4 48,000 20.9 35 31−3/16 x 31−3/16 x 28−7/16(792 x 792 x 722)200/182 (91/82) NXA460GKC 5 60,000 27.5 40 31−3/16 x 31−3/16 x 31−13/16(792 x 792 x 808)218/197 (99/89) COMMERCIAL™NXA4 Performance Series Product Specifications PRODUCT SPECIFICATIONS Split System Air Conditioner: NXA4 2 421 71 6240 05Specifications subject to change without notice. OUTDOOR UNIT MODEL NUMBER IDENTIFICATION GUIDE Digit Position:1 2 3 4 5, 6 7 8 9 10 11 Example Part Number:N X A 4 18 G K C 1 0 N = Entry BRANDING X = R−410A REFRIGERANT A = Air Conditioner H = Heat Pump TYPE 3 = 13 SEER 4 = 14 SEER NOMINAL EFFICIENCY 18 = 18,000 BTUH = 1−1/2 tons 24 = 24,000 BTUH = 2 tons 30 = 30,000 BTUH = 2−1/2 tons 36 = 36,000 BTUH = 3 tons 42 = 42,000 BTUH = 3−1/2 tons 48 = 48,000 BTUH = 4 tons 60 = 60,000 BTUH = 5 tons NOMINAL CAPACITY G = Coil Guard Grille FEATURES K = 208/230−1−60 VOLTAGE Sales Code Engineering Revision Extra Digit ACCESSORIES PART NUMBER IDENTIFICATION GUIDE Digit Position:1 2 3 4 5 6, 7 8, 9 10, 11 Example Part Number:N A S A 0 0 1 01 C H N = Non−Branded BRANDING A = Accessory PRODUCT GROUP S = Split System (AC & HP)KIT USAGE A = Original B = 2nd Generation MAJOR SERIES 0 = Generic or Not Applicable 2 = R−22 4 = R−410A REFRIGERANT Product Identifier Number Package Quantity Type of Kit (Example: CH = Crankcase Heater) PRODUCT SPECIFICATIONS Split System Air Conditioner: NXA4421 71 6240 053Specifications subject to change without notice.SD5272−4 REV B 1. Allow 24” clearance to service side of unit, 48” above unit, 6“ on one side, 12” on remaining sides. 2. Maintain a distance of 24” between units or 18” if no overhang within 12’. 3. Minimum outdoor operating ambient in cooling mode is 55ºF, max 125ºF. 4. Center of Gravity Model Dimensions Inches (English) A B C D E F G K L M N P Minimum Ground Mounting Pad Size X Minimum Rooftop Mounting Pad Size Y Shipping Dimensions L x W x H NXA418GKC 23−1/8 24−13/16 3−3/4 3/4 4−7/16 18−1/16 7−13/16 2−13/16 1/2 13 11 −1/8 10−1/4 23−1/8 x 23−1/8 17−3/4 x 17−3/4 25−1/4 x 25−1/4 x 27−3/16 NXA424GKC 25−3/4 25 3−3/4 3/4 4−7/16 21−1/4 9−1/8 2−13/16 1/2 13−5/8 12−1/8 9−7/8 25−3/4 x 25−3/4 20−7/16 x 20−7/16 27−7/8 x 27−7/8 x 32−9/16 NXA430GKC 31−3/16 31−13/16 3−3/4 3/4 6−9/16 24−11/16 9−1/8 2−13/16 1/2 16−1/8 15−1/16 12−5/8 31−3/16 x 31−3/16 23 x 23 33−3/8 x 33−3/8 x 34 NXA436GKC 31−3/16 24−13/16 3−7/8 7/8 6−9/16 24−11/16 9−1/8 2−15/16 5/8 15−9/16 16−1/2 10−1/4 31−3/16 x 31−3/16 23 x 23 33−3/8 x 33−3/8 x 27−3/16 NXA442GKC 31−3/16 39−1/8 3−7/8 7/8 6−9/16 24−11/16 9−1/8 2−15/16 5/8 16−1/8 16−11/16 14 31−3/16 x 31−3/16 23 x 23 33−3/8 x 33−3/8 x 40−5/8 NXA448GKC 31−3/16 28−7/16 3−7/8 7/8 6−9/16 24−11/16 9−1/8 2−15/16 5/8 16−3/16 16−1/4 10−1/4 31−3/16 x 31−3/16 23 x 23 33−3/8 x 33−3/8 x 30−5/8 NXA460GKC 31−3/16 31−13/16 3−7/8 7/8 6−9/16 24−11/16 9−1/8 2−15/16 5/8 15−1/2 16 10−7/8 35 x 35 26−3/4 x 26−3/7 33−3/8 x 33−3/8 x 34 PRODUCT SPECIFICATIONS Split System Air Conditioner: NXA44421 71 6240 05Specifications subject to change without notice.SD5272−4 REV B 1. Allow 610 mm clearance to service side of unit, 1219 mm above unit, 152 mm on one side, 305 mm on remaining sides 2. Maintain a distance of 610mm between units or 457mm if no overhang within 3.7m. 3. Minimum outdoor operating ambient in cooling mode is 13ºC, max 52ºC. 4. Center of Gravity Model Dimensions mm (SI Metric) A B C D E F G K L M N P Minimum Ground Mounting Pad Size X Minimum Rooftop Mounting Pad Size Y Shipping Dimensions L x W x H NXA418GKC 587 630 95 19 113 459 198 71 13 330 283 260 587 x 587 451 x 451 642 x 642 x 691 NXA424GKC 654 635 95 19 113 540 232 71 13 346 308 251 654 x 654 518 x 518 708 x 708 x 827 NXA430GKC 792 808 95 19 113 627 232 71 13 410 383 321 792 x 792 583 x 583 847 x 847 x 864 NXA436GKC 792 630 98 22 167 627 232 75 16 395 419 260 792 x 792 583 x 583 847 x 847 x 691 NXA442GKC 792 994 98 22 167 627 232 75 16 410 424 356 792 x 792 583 x 583 847 x 847 x 1031 NXA448GKC 792 722 98 22 167 627 232 75 16 411 413 260 792 x 792 583 x 583 847 x 847 x 778 NXA460GKC 792 808 98 22 167 627 232 75 16 394 406 276 792 x 792 583 x 583 847 x 847 x 864 PRODUCT SPECIFICATIONS Split System Air Conditioner: NXA4 421 71 6240 05 5Specifications subject to change without notice. PHYSICAL DATA (1−phase) Model Size 18 24 30 36 42 48 60 Nominal Cooling Capacity (BTU/hr)18,000 24,000 30,000 36,000 42,000 48,000 60,000 Nominal SEER 14.0 Compressor Type Scroll REFRIGERANT R−410A Factory Charge −lb(kg)3.72(1.69)3.87(1.75)5.67(2.57)5.42(2.46)7.90(3.58)8.31(3.77)9.39(4.26) Required Charge −lb(kg)4.77(2.16)4.20(1.91)5.67(2.57)5.42(2.46)7.90(3.58)8.31(3.77)9.39(4.26) Required Subcooling °F (°C)16 (8.8)10 (5.5)12(6.6)11 (6)9 (5)11 (6)13 (7.2) COND FAN Propeller Type, Direct Drive Air Discharge Vertical Air Qty (CFM)1600 1881 2614 3310 3700 3454 3700 Motor HP 1/12 1/12 1/10 1/5 1/4 1/4 1/4 Motor RPM 1100 1100 1100 1100 1110 1110 1100 COND COIL Face Area (Sq ft)8.4 9.9 17.24 12.9 21.6 15.1 17.25 Fins per In.25 25 25 20 25 20 25 Rows 1 1 1 1 1 2 2 Circuits 3 4 4 5 7 6 8 VALVE CONNECT. (In. ID) Vapor − in. (mm)3/4 (19)3/4 (19)3/4 (19)7/8 (22)7/8 (22)7/8 (22)7/8 (22) Liquid − in. (mm)3/8 (10) REFRIGERANT TUBES* (In. OD) Rated Vapor 3/4 (19)3/4 (19)3/4 (19)7/8 (22)7/8 (22)7/8 (22)1 1/8 (29) Max Liquid Line 3/8 (10) * Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. Note: See unit Installation Instruction for proper installation. A-Weighted Sound Power Level - Without Sound Jacket Model Standard Rating (dBA) TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment) 125 250 500 1000 2000 4000 8000 NXA418GKC 75 45 53 57 62 60 53 48 NXA424GKC 72 46 57 60 64 61 56 50 NXA430GKC 73 50 56 63 64 61 58 54 NXA436GKC 75 51 61 65 67 63 60 53 NXA442GKC 73 49 58 63 64 59 56 50 NXA448GKC 76 53 61 64 66 62 60 51 NXA460GKC 75 54 57 63 64 62 58 51 Note: Tested in accordance with AHRI Standard 270-2008 (not listed in AHRI). A-Weighted Sound Power Level - With Sound Jacket Model Standard Rating (dBA) TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment) 125 250 500 1000 2000 4000 8000 NXA418GKC 75 45 53 58 62 61 55 49 NXA424GKC 73 47 59 61 64 61 55 48 NXA430GKC 72 49 57 62 63 60 57 52 NXA436GKC 75 51 62 65 66 62 60 52 NXA442GKC 72 50 58 62 63 58 55 47 NXA448GKC 73 55 61 64 63 60 57 48 NXA460GKC 73 54 59 63 63 60 56 48 Note: Tested in accordance with AHRI Standard 270-2008 (not listed in AHRI). PRODUCT SPECIFICATIONS Split System Air Conditioner: NXA4 6 421 71 6240 05Specifications subject to change without notice. ELECTRICAL DATA (208/230−1−60, voltage range 197V − 253V) Model Size 18 24 30 36 42 48 60 Minimum Circuit Ampacity − MCA (amps)11.7 14.1 16.8 18.1 22.3 20.9 27.5 Maximum OverCurrent Protective device − MOCP (amps)20 20 25 30 35 35 40 Compressor RLA (Rated Load Amps) LRA (Locked Rotor Amps) 9 47.5 10.9 62.9 12.8 67.8 13.6 79.0 16.7 109.0 15.6 105.7 20.8 127.1 Fan Motor FLA (Full Load Amps).40 .50 .75 1.10 1.40 1.40 1.52 REFRIGERANT CHARGE ADJUSTMENTS Liquid Line Size R-410A Charge oz/ft 3/8 0.60 (Factory charge for lineset = 9 oz) 5/16 0.40 1/4 0.27 Units are factory charged for 15 ft (4.6 m) of 3/8” liquid line. The factory charge for 3/8” lineset 9 oz. When using other length or diameter liquid lines, charge adjustments are required per the chart above. Charging Formula: [(Lineset oz/ft x total length) – (factory charge for lineset)] = charge adjustment Example 1: System has 15 ft of line set using existing 1/4“ liquid line. What charge adjustment is required? Formula: (.27 oz/ft x 15ft) – (9 oz) = (-4.95) oz. Net result is to remove 4.95 oz of refrigerant from the system Example 2: System has 45 ft of existing 5/16” liquid line. What is the charge adjustment? Formula: (.40 oz/ft. x 45ft) – (9 oz.) = 9 oz. Net result is to add 9 oz of refrigerant to the system LONG LINE APPLICATIONS An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units. For Air Conditioner systems, the charts below shows when an application requires a TXV and long line accessories due to lineset length. AC with R−410A Refrigerant Long Line Description ft (m) Beyond these lengths, a TXV is required Total Length Outdoor Unit Above or Below Indoor Unit TXV required beyond 50 ft. (15.2 m)TXV required beyond 20 ft. (6.1 m) AC with R−410A Refrigerant Long Line Description ft (m) (Beyond these lengths, long line accessories are required) Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor 1/4 + TXV No accessories needed within al lowed lengths No accessories needed within allowed lengths 175 (53.3) 5/16 + TXV 120 (36.6)50 (15.2) vertical or 120 (36.6) total 120 (36.6) 3/8 + TXV 80 (24.4)35 (10.7) vertical or 80 (24.4) total 80 (24.4) Note: See Long Line Guideline for details PRODUCT SPECIFICATIONS Split System Air Conditioner: NXA4 421 71 6240 05 7Specifications subject to change without notice. R−410A COOLING CAPACITY LOSS FOR VARIOUS LINE LENGTHS & TUBE DIAMETERS Model Size Liquid Line in.(mm) Acceptable Vapor Line Sizes in. (mm) Cooling Capacity Loss (%) at Total Equivalent Line Length, feet (m) Refer to Long Line Application Guideline to calculate equivalent length Standard Application Long Line Application (Requires Accessories) 25’ (7.6) 50’ (15.2) 80’ (24.4) 81’ (24.7) 100’ (30.5) 125’ (38.1) 150’ (45.7) 175’ (53.3) 200’ (61) 225’ (68.6) 250’ (76.2) 18 3/8 (10) 1/2 (13)1 2 3 3 4 6 7 8 9 10 12 5/8 (16)0 0 1 1 1 1 2 2 3 3 3 3/4 (19)0 0 0 0 0 1 1 1 1 1 1 24 5/8 (16)0 1 1 1 2 3 3 4 4 5 6 3/4 (19)0 0 0 0 0 1 1 1 1 1 2 7/8 (22)0 0 0 0 0 0 0 0 0 0 1 30 5/8 (16)1 2 3 3 3 4 5 6 7 8 9 3/4 (19)0 0 1 1 1 1 2 2 2 3 3 7/8 (22)0 0 0 0 0 1 1 1 1 1 1 36 5/8 (16)1 2 4 4 5 6 7 9 10 11 13 3/4 (19)0 0 1 1 1 2 2 3 3 4 4 7/8 (22)0 0 0 0 0 1 1 1 1 2 2 42 3/4 (19)0 1 2 2 2 3 4 4 5 6 6 7/8 (22)0 0 1 1 1 1 2 2 2 3 3 1−1/8 (29)0 0 0 0 0 0 0 0 0 0 1 48 3/4 (19)0 1 2 2 3 4 5 5 6 7 8 7/8 (22)0 0 1 1 1 2 2 2 3 3 4 1−1/8 (29)0 0 0 0 0 0 0 0 1 1 1 60 3/4 (19)1 2 4 4 5 6 7 9 10 11 12 7/8 (22)0 1 2 2 2 3 4 4 5 5 6 1−1/8(29)0 0 0 0 1 1 1 1 1 1 2 Consult the Long Line Application Guideline document before purchasing/installing line sets. Applications in shaded area may have height restrictions that limit allowable total equivalent length when outdoor unit is below indoor unit. COOLING PERFORMANCE FOR COMBINATION RATINGS Indoor Models For complete ratings information, use the AHRI website directory search: www.AHRIdirectory.org. New ratings may be listed online before Specification Sheets are updated. Unit Size INDOOR MODEL AHRI STANDARD RATINGS FURNACE MODEL COOLING CAPACITY FACTORY ENHANCE SEER EERSTANDARDTDRTXV NXA418GKC EA*4X19L17A*17,500 TXV 14.00 11.70 NXA424GKC EA*4X25L17A*23,400 TXV 14.00 11.70 NXA430GKC EA*4X37L21A*29,600 TXV 14.50 12.00 NXA436GKC EA*4X37L21A*34,200 TXV 14.00 12.00 NXA442GKC EA*4X43L21A*38,500 TXV 14.00 12.00 NXA448GKC EA*4X61L24A*45,000 TXV 14.50 11.70 NXA460GKC EA*4X60L24A*56,500 TXV 14.00 11.70 PRODUCT SPECIFICATIONS Split System Air Conditioner: NXA4 8 421 71 6240 05Specifications subject to change without notice. EXPANDED COOLING PERFORMANCE RATINGS For Outdoor / Indoor Models # For complete ratings information, use the AHRI website directory search: www.AHRIdirectory.org. New ratings may be listed online before Specification Sheets are updated. EVAPORA- TOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125 (51.7) CFM EWB °F Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW**Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens ‡ NXA418GKC Outdoor Section With EA*4X30L17** Indoor Section 525 72 20.84 11.15 1.18 20.08 10.86 1.33 19.26 10.56 1.49 18.34 10.22 1.67 17.28 9.84 1.89 16.07 9.40 2.13 67 19.05 13.80 1.19 18.30 13.49 1.34 17.50 13.16 1.50 16.60 12.80 1.68 15.58 12.39 1.89 14.40 11.93 2.13 63 17.78 13.32 1.20 17.04 12.99 1.34 16.24 12.64 1.50 15.35 12.25 1.68 14.35 11.82 1.89 13.21 11.33 2.14 62 17.42 16.39 1.20 16.70 16.06 1.34 15.92 15.68 1.50 15.12 15.12 1.68 14.34 14.34 1.89 13.45 13.45 2.13 57 17.00 17.00 1.20 16.41 16.41 1.34 15.79 15.79 1.50 15.10 15.10 1.68 14.32 14.32 1.89 13.43 13.43 2.13 600 72 21.18 11.76 1.21 20.40 11.48 1.35 19.56 11.17 1.52 18.61 10.83 1.70 17.52 10.45 1.92 16.27 10.01 2.16 67 19.36 14.78 1.22 18.61 14.48 1.36 17.78 14.15 1.52 16.86 13.79 1.71 15.81 13.37 1.92 14.62 12.90 2.16 63 18.10 14.24 1.23 17.35 13.91 1.37 16.53 13.56 1.53 15.62 13.17 1.71 14.59 12.73 1.92 13.42 12.24 2.16 62 17.79 17.69 1.23 17.14 17.14 1.37 16.49 16.49 1.53 15.76 15.76 1.71 14.94 14.94 1.92 14.00 14.00 2.16 57 17.72 17.72 1.23 17.11 17.11 1.37 16.46 16.46 1.53 15.74 15.74 1.71 14.92 14.92 1.92 13.98 13.98 2.16 675 72 21.42 12.36 1.23 20.63 12.08 1.38 19.76 11.77 1.55 18.80 11.43 1.73 17.69 11.05 1.94 16.41 10.61 2.19 67 19.60 15.75 1.25 18.83 15.44 1.39 17.99 15.11 1.55 17.05 14.75 1.73 15.99 14.33 1.95 14.77 13.85 2.19 63 18.34 15.14 1.26 17.57 14.81 1.40 16.74 14.45 1.56 15.82 14.06 1.74 14.77 13.61 1.95 13.59 13.10 2.19 62 18.33 18.33 1.25 17.71 17.71 1.40 17.04 17.04 1.55 16.28 16.28 1.74 15.43 15.43 1.95 14.46 14.46 2.19 57 18.31 18.31 1.25 17.68 17.68 1.40 17.01 17.01 1.55 16.26 16.26 1.74 15.41 15.41 1.95 14.44 14.44 2.19 EVAPORA- TOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125 (51.7) CFM EWB °F Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW**Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens ‡ NXA424GKC Outdoor Section With EA*4X25L17* Indoor Section 700 72 27.81 14.89 1.62 26.74 14.49 1.80 25.61 14.07 2.00 24.39 13.62 2.23 23.06 13.14 2.51 21.56 12.60 2.83 67 25.46 18.45 1.62 24.46 18.04 1.80 23.40 17.61 2.00 22.25 17.13 2.23 21.01 16.63 2.51 19.58 16.06 2.83 63 23.79 17.82 1.62 22.84 17.40 1.80 21.83 16.94 2.00 20.74 16.47 2.24 19.53 15.94 2.52 18.16 15.36 2.85 62 23.31 21.92 1.62 22.38 21.48 1.80 21.40 21.01 2.00 20.37 20.37 2.24 19.43 19.43 2.51 18.33 18.33 2.84 57 22.74 22.74 1.62 22.00 22.00 1.80 21.20 21.20 2.00 20.34 20.34 2.24 19.39 19.39 2.51 18.30 18.30 2.84 800 72 28.26 15.70 1.66 27.15 15.30 1.84 25.97 14.87 2.04 24.70 14.42 2.27 23.33 13.94 2.54 21.80 13.40 2.87 67 25.87 19.75 1.66 24.84 19.33 1.84 23.75 18.90 2.04 22.56 18.42 2.27 21.27 17.91 2.55 19.81 17.34 2.87 63 24.22 19.04 1.66 23.25 18.61 1.84 22.19 18.15 2.04 21.05 17.67 2.28 19.82 17.14 2.55 18.40 16.54 2.88 62 23.79 23.64 1.66 22.94 22.94 1.84 22.09 22.09 2.04 21.17 21.17 2.27 20.16 20.16 2.55 19.00 19.00 2.87 57 23.69 23.69 1.66 22.90 22.90 1.84 22.06 22.06 2.04 21.14 21.14 2.27 20.13 20.13 2.55 18.98 18.98 2.87 900 72 28.57 16.50 1.70 27.42 16.10 1.87 26.21 15.67 2.08 24.91 15.21 2.31 23.51 14.73 2.58 21.94 14.19 2.90 67 26.18 21.03 1.70 25.11 20.60 1.88 23.99 20.16 2.08 22.77 19.68 2.31 21.46 19.16 2.58 19.98 18.58 2.91 63 24.53 20.22 1.70 23.52 19.79 1.88 22.44 19.33 2.08 21.28 18.83 2.32 20.02 18.30 2.59 18.58 17.68 2.92 62 24.50 24.50 1.70 23.67 23.67 1.88 22.78 22.78 2.08 21.82 21.82 2.31 20.76 20.76 2.59 19.55 19.55 2.91 57 24.47 24.47 1.70 23.64 23.64 1.88 22.75 22.75 2.08 21.79 21.79 2.31 20.73 20.73 2.59 19.52 19.52 2.91 PRODUCT SPECIFICATIONS Split System Air Conditioner: NXA4 421 71 6240 05 9Specifications subject to change without notice. EVAPORA- TOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125 (51.7) CFM EWB °F Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW**Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens ‡ NXA430GKC Outdoor Section With EA*4X37L21A* Indoor Section 875 72 34.17 17.94 1.96 32.63 17.38 2.16 31.02 16.79 2.40 29.33 16.18 2.66 27.51 15.54 2.98 25.57 14.86 3.35 67 31.02 22.10 1.97 29.61 21.53 2.17 28.14 20.94 2.40 26.58 20.31 2.66 24.91 19.66 2.98 23.13 18.96 3.35 63 28.77 21.25 1.97 27.46 20.67 2.17 26.08 20.08 2.40 24.62 19.45 2.67 23.07 18.79 2.98 21.39 18.09 3.35 62 28.19 26.15 1.97 26.92 25.56 2.17 25.60 25.36 2.40 24.34 24.34 2.66 23.11 23.11 2.98 21.76 21.76 3.35 57 27.51 27.51 1.97 26.51 26.51 2.17 25.45 25.45 2.40 24.30 24.30 2.66 23.07 23.07 2.98 21.73 21.73 3.35 1000 72 34.79 18.95 2.01 33.19 18.37 2.21 31.51 17.78 2.44 29.73 17.16 2.71 27.85 16.51 3.03 25.85 15.82 3.40 67 31.61 23.69 2.01 30.13 23.11 2.21 28.60 22.50 2.44 26.98 21.87 2.71 25.25 21.19 3.03 23.42 20.49 3.40 63 29.34 22.73 2.02 27.97 22.14 2.22 26.53 21.53 2.45 25.01 20.89 2.71 23.40 20.21 3.03 21.68 19.49 3.40 62 28.87 28.71 2.01 27.71 27.71 2.22 26.56 26.56 2.45 25.33 25.33 2.71 24.00 24.00 3.03 22.57 22.57 3.40 57 28.75 28.75 2.01 27.66 27.66 2.22 26.52 26.52 2.45 25.29 25.29 2.71 23.97 23.97 3.03 22.54 22.54 3.40 1125 72 35.24 19.93 2.06 33.57 19.35 2.26 31.84 18.74 2.49 30.02 18.11 2.76 28.08 17.45 3.08 26.02 16.75 3.45 67 32.05 25.24 2.06 30.53 24.64 2.26 28.94 24.02 2.49 27.27 23.37 2.76 25.51 22.69 3.08 23.63 21.95 3.45 63 29.77 24.16 2.06 28.34 23.56 2.26 26.86 22.94 2.49 25.30 22.28 2.76 23.65 21.59 3.08 21.90 20.83 3.45 62 29.83 29.83 2.06 28.67 28.67 2.26 27.45 27.45 2.49 26.15 26.15 2.76 24.74 24.74 3.07 23.23 23.23 3.45 57 29.79 29.79 2.06 28.63 28.63 2.26 27.41 27.41 2.49 26.11 26.11 2.76 24.71 24.71 3.07 23.20 23.20 3.45 EVAPORA- TOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125 (51.7) CFM EWB °F Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW**Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens ‡ NXA436GKC Outdoor Section With EA*4X37L21A* Indoor Section 1050 72 41.01 22.33 2.30 39.34 21.71 2.58 37.16 20.92 2.85 34.76 20.05 3.16 32.31 19.19 3.53 29.95 18.38 4.00 67 38.18 28.11 2.30 36.67 27.49 2.57 34.60 26.64 2.84 32.34 25.73 3.14 30.03 24.81 3.50 27.81 23.93 3.98 63 35.95 27.24 2.31 34.52 26.60 2.58 32.59 25.75 2.84 30.42 24.81 3.13 28.19 23.85 3.50 26.15 22.98 3.98 62 35.34 33.63 2.31 33.97 32.97 2.57 32.13 32.02 2.83 30.31 30.31 3.13 28.47 28.47 3.50 26.72 26.72 3.98 57 34.72 34.72 2.32 33.59 33.59 2.58 32.04 32.04 2.84 30.27 30.27 3.13 28.43 28.43 3.50 26.69 26.69 3.98 1200 72 41.38 23.50 2.36 39.65 22.88 2.64 37.35 22.06 2.91 34.95 21.21 3.22 32.45 20.34 3.59 30.04 19.50 4.06 67 38.62 30.04 2.36 37.06 29.41 2.63 34.94 28.56 2.90 32.63 27.64 3.20 30.27 26.71 3.56 27.99 25.80 4.04 63 36.46 29.05 2.37 34.99 28.41 2.63 32.98 27.54 2.89 30.76 26.59 3.19 28.46 25.61 3.55 26.38 24.71 4.04 62 36.09 35.91 2.37 34.84 34.84 2.63 33.16 33.16 2.89 31.29 31.29 3.19 29.34 29.34 3.56 27.44 27.44 4.04 57 36.00 36.00 2.37 34.79 34.79 2.63 33.12 33.12 2.89 31.24 31.24 3.19 29.30 29.30 3.56 27.42 27.42 4.04 1350 72 41.60 24.63 2.42 39.82 24.00 2.70 37.54 23.20 2.97 35.04 22.33 3.28 32.50 21.46 3.65 30.06 20.63 4.12 67 38.92 31.92 2.41 37.32 31.28 2.68 35.15 30.42 2.95 32.81 29.49 3.26 30.41 28.52 3.62 28.13 27.55 4.10 63 36.82 30.81 2.42 35.31 30.16 2.69 33.26 29.28 2.95 31.00 28.31 3.25 28.69 27.30 3.62 26.56 26.31 4.10 62 37.07 37.07 2.42 35.77 35.77 2.68 33.98 33.98 2.95 32.01 32.01 3.25 29.98 29.98 3.62 27.99 27.99 4.10 57 37.02 37.02 2.42 35.73 35.73 2.68 33.95 33.95 2.95 31.98 31.98 3.25 29.95 29.95 3.62 27.97 27.97 4.10 EVAPORA- TOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125 (51.7) CFM EWB °F Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW**Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens ‡ NXA442GKC Outdoor Section With EB*4X43L21 Indoor Section 1225 72 46.79 25.57 2.60 44.65 24.77 2.86 42.40 23.95 3.15 40.04 23.09 3.47 37.52 22.19 3.84 34.83 21.24 4.26 67 42.38 31.68 2.61 40.45 30.89 2.86 38.42 30.07 3.15 36.27 29.20 3.47 33.99 28.29 3.84 31.54 27.32 4.25 63 39.24 30.38 2.61 37.46 29.59 2.86 35.58 28.77 3.15 33.58 27.91 3.47 31.47 26.99 3.83 29.19 26.02 4.24 62 38.60 37.63 2.61 36.93 36.70 2.86 35.35 35.35 3.14 33.75 33.75 3.47 32.02 32.02 3.83 30.14 30.14 4.24 57 38.17 38.17 2.61 36.78 36.78 2.86 35.29 35.29 3.14 33.70 33.70 3.47 31.98 31.98 3.83 30.10 30.10 4.24 1400 72 47.55 27.01 2.67 45.33 26.20 2.93 42.99 25.37 3.21 40.52 24.49 3.54 37.91 23.57 3.91 35.15 22.61 4.32 67 43.11 33.98 2.67 41.10 33.17 2.93 38.99 32.32 3.21 36.77 31.44 3.54 34.41 30.50 3.90 31.91 29.50 4.32 63 39.94 32.51 2.67 38.08 31.70 2.93 36.14 30.86 3.21 34.06 29.97 3.54 31.88 29.03 3.90 29.56 28.02 4.31 62 39.87 39.87 2.67 38.37 38.37 2.93 36.76 36.76 3.21 35.04 35.04 3.54 33.19 33.19 3.90 31.17 31.17 4.32 57 39.81 39.81 2.67 38.31 38.31 2.93 36.71 36.71 3.21 34.99 34.99 3.54 33.14 33.14 3.90 31.13 31.13 4.31 1575 72 48.11 28.39 2.74 45.80 27.57 2.99 43.39 26.72 3.28 40.85 25.83 3.61 38.17 24.91 3.98 35.33 23.93 4.39 67 43.66 36.19 2.74 41.58 35.36 2.99 39.41 34.49 3.28 37.13 33.57 3.60 34.73 32.60 3.97 32.20 31.50 4.38 63 40.46 34.55 2.74 38.54 33.72 2.99 36.53 32.85 3.28 34.42 31.93 3.60 32.20 30.94 3.97 29.88 29.72 4.38 62 41.18 41.18 2.74 39.58 39.58 2.99 37.88 37.88 3.28 36.06 36.06 3.60 34.10 34.10 3.97 31.98 31.98 4.38 57 41.12 41.12 2.74 39.53 39.53 2.99 37.83 37.83 3.28 36.01 36.01 3.60 34.05 34.05 3.97 31.94 31.94 4.38 PRODUCT SPECIFICATIONS Split System Air Conditioner: NXA4 10 421 71 6240 05Specifications subject to change without notice. EVAPORA- TOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125 (51.7) CFM EWB °F Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW**Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens ‡ NXA448GKC Outdoor Section With EA*4X61L24* Indoor Section 1400 72 53.91 26.70 3.12 51.70 25.95 3.46 49.29 25.14 3.81 46.61 24.25 4.20 43.50 23.23 4.66 39.94 22.07 5.22 67 49.07 33.08 3.15 47.03 32.30 3.47 44.83 31.48 3.81 42.36 30.56 4.19 39.52 29.52 4.65 36.26 28.33 5.22 63 45.60 31.80 3.16 43.67 31.02 3.48 41.61 30.19 3.81 39.31 29.27 4.18 36.66 28.22 4.64 33.61 27.02 5.22 62 44.81 39.26 3.16 42.96 38.43 3.48 41.03 40.90 3.80 39.14 39.14 4.18 36.99 36.99 4.64 34.49 34.49 5.22 57 44.02 44.02 3.16 42.51 42.51 3.48 40.91 40.91 3.80 39.08 39.08 4.18 36.94 36.94 4.64 34.44 34.44 5.22 1600 72 54.74 28.18 3.20 52.46 27.42 3.54 49.97 26.60 3.89 47.17 25.68 4.28 43.95 24.64 4.74 40.30 23.48 5.30 67 49.91 35.43 3.22 47.78 34.64 3.55 45.50 33.80 3.89 42.95 32.87 4.27 40.01 31.79 4.73 36.67 30.58 5.30 63 46.41 33.99 3.23 44.41 33.19 3.55 42.28 32.35 3.89 39.89 31.40 4.26 37.15 30.32 4.72 34.04 29.09 5.30 62 45.97 45.97 3.23 44.36 44.36 3.55 42.62 42.62 3.89 40.65 40.65 4.27 38.35 38.35 4.73 35.68 35.68 5.30 57 45.90 45.90 3.23 44.29 44.29 3.55 42.56 42.56 3.89 40.59 40.59 4.27 38.30 38.30 4.73 35.63 35.63 5.30 1800 72 55.35 29.59 3.27 53.00 28.82 3.62 50.43 27.99 3.97 47.55 27.07 4.35 44.26 26.02 4.82 40.51 24.83 5.38 67 50.51 37.70 3.29 48.34 36.90 3.63 45.99 36.05 3.97 43.37 35.09 4.35 40.38 33.98 4.81 37.00 32.68 5.38 63 47.02 36.10 3.31 44.97 35.29 3.63 42.77 34.42 3.97 40.33 33.45 4.34 37.54 32.33 4.81 34.39 30.98 5.38 62 47.51 47.51 3.31 45.80 45.80 3.63 43.96 43.96 3.97 41.87 41.87 4.35 39.44 39.44 4.81 36.63 36.63 5.38 57 47.45 47.45 3.31 45.74 45.74 3.63 43.91 43.91 3.97 41.82 41.82 4.35 39.40 39.40 4.81 36.58 36.58 5.38 EVAPORA- TOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125 (51.7) CFM EWB °F Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW** Capacity MBtuh Total Sys tem KW**Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens‡ NXA460GKC Outdoor Section With EA*4X60L24A* Indoor Section 1750 72 68.41 35.82 4.01 65.35 34.67 4.39 62.15 33.49 4.86 58.70 32.23 5.39 55.01 30.89 5.96 50.87 29.41 6.55 67 62.24 44.04 4.01 59.41 42.88 4.38 56.50 41.69 4.83 53.38 40.43 5.35 50.00 39.08 5.91 46.23 37.59 6.49 63 57.78 42.37 4.02 55.13 41.19 4.37 52.41 39.99 4.81 49.54 38.75 5.32 46.39 37.40 5.87 42.89 35.91 6.45 62 56.92 52.17 4.02 54.40 50.96 4.37 51.84 49.69 4.81 49.16 49.16 5.32 46.64 46.64 5.88 43.73 43.73 6.46 57 55.64 55.64 4.02 53.56 53.56 4.37 51.43 51.43 4.81 49.13 49.13 5.32 46.56 46.56 5.88 43.68 43.68 6.46 2000 72 69.54 37.55 4.10 66.36 36.39 4.49 63.04 35.18 4.96 59.50 33.91 5.49 55.63 32.53 6.06 51.36 31.03 6.66 67 63.30 46.83 4.11 60.35 45.64 4.47 57.34 44.44 4.93 54.11 43.16 5.45 50.61 41.77 6.01 46.74 40.24 6.60 63 58.79 44.95 4.11 56.04 43.76 4.47 53.23 42.55 4.91 50.24 41.27 5.42 47.00 39.89 5.98 43.39 38.33 6.56 62 58.25 55.83 4.11 55.72 55.33 4.47 53.37 53.37 4.91 50.91 50.91 5.43 48.16 48.16 5.99 45.09 45.09 6.58 57 57.80 57.80 4.11 55.59 55.59 4.47 53.30 53.30 4.91 50.84 50.84 5.43 48.11 48.11 5.99 45.03 45.03 6.58 2250 72 70.37 39.17 4.20 67.10 37.99 4.59 63.67 36.77 5.06 60.02 35.48 5.59 56.04 34.08 6.17 51.66 32.55 6.76 67 64.08 49.47 4.20 61.08 48.28 4.57 57.95 47.04 5.03 54.64 45.73 5.55 51.07 44.31 6.12 47.12 42.69 6.70 63 59.56 47.41 4.20 56.73 46.20 4.56 53.82 44.95 5.01 50.77 43.65 5.52 47.44 42.21 6.08 43.78 40.57 6.66 62 59.69 59.69 4.20 57.32 57.32 4.56 54.90 54.90 5.02 52.28 52.28 5.53 49.41 49.41 6.10 46.17 46.17 6.69 57 59.58 59.58 4.20 57.25 57.25 4.56 54.83 54.83 5.02 52.23 52.23 5.53 49.35 49.35 6.10 46.12 46.12 6.69 Sensible capacities shown are based on 80 F (27 C) entering air at the indoor coil. For sensible capacities at other than 80 F (27 C), deduct 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80 F (27 C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80 F (27 C). # Expanded cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240-2008. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. ** System kw is total of indoor and outdoor unit kilowatts. At TVA rating indoor condition (75 F edb/63 F ewb). All other indoor air temperatures are at 80 F edb. NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. EWB — Entering Wet Bulb PRODUCT SPECIFICATIONS Split System Air Conditioner: NXA4 421 71 6240 05 11Specifications subject to change without notice. CONDENSER ONLY RATINGS SST °F (°C) CONDENSER ENTERING AIR TEMPERATURES °F (°C) 55 (12.78)65 (18.33)75 (23.89)85 (29.44)95 (35.0)105 (40.56)115 (46.11)125 (51.67) NXA418GKC 30 (1.11) TCG 16.00 14.90 13.90 12.90 12.00 10.90 9.80 8.60 SDT 73.60 83.20 92.80 102.60 112.40 122.40 132.30 142.40 KW 0.77 0.88 0.99 1.12 1.27 1.44 1.65 1.88 35 (1.67) TCG 17.60 16.50 15.40 14.40 13.40 12.20 11.00 9.80 SDT 75.00 84.60 94.30 104.00 113.80 123.50 133.50 143.50 KW 0.77 0.88 1.00 1.13 1.28 1.46 1.66 1.90 40 (4.44) TCG 19.40 18.20 17.10 16.00 14.90 13.70 12.40 11.00 SDT 76.50 86.10 95.80 105.40 115.00 124.80 134.60 144.60 KW 0.77 0.88 1.00 1.14 1.29 1.47 1.67 1.91 45 (7.22) TCG 21.20 20.00 18.90 17.70 16.50 15.20 13.80 12.30 SDT 78.00 87.50 97.10 106.70 116.40 126.10 135.90 145.70 KW 0.77 0.88 1.01 1.14 1.30 1.48 1.69 1.93 50 (10.0) TCG 23.20 22.00 20.80 19.50 18.30 16.90 15.40 13.80 SDT 79.30 88.90 98.50 108.10 117.70 127.40 137.10 146.90 KW 0.76 0.88 1.01 1.15 1.30 1.49 1.70 1.94 55 (12.78) TCG 25.30 24.00 22.80 21.50 20.10 18.70 17.10 15.40 SDT 80.80 90.40 100.00 109.50 119.10 128.80 138.40 148.00 KW 0.75 0.87 1.00 1.15 1.31 1.50 1.71 1.95 NXA424GKC 30 (1.11) TCG 21.30 20.10 18.90 17.70 16.60 15.40 14.20 13.00 SDT 69.90 79.40 88.80 98.30 107.80 117.30 126.70 136.10 KW 1.05 1.21 1.37 1.54 1.74 1.96 2.22 2.52 35 (1.67) TCG 23.40 22.10 20.80 19.60 18.30 17.10 15.80 14.40 SDT 71.10 80.60 90.00 99.50 108.90 118.20 127.50 136.90 KW 1.06 1.21 1.37 1.54 1.74 1.96 2.22 2.52 40 (4.44) TCG 25.60 24.20 22.90 21.50 20.20 18.80 17.40 15.90 SDT 72.40 81.80 91.20 100.60 109.80 119.10 128.40 137.70 KW 1.06 1.21 1.37 1.55 1.74 1.97 2.22 2.53 45 (7.22) TCG 28.00 26.50 25.10 23.60 22.10 20.60 19.00 17.40 SDT 73.80 83.20 92.40 101.70 110.90 120.20 129.40 138.60 KW 1.07 1.22 1.37 1.55 1.74 1.97 2.23 2.53 50 (10.0) TCG 30.50 28.90 27.30 25.80 24.10 22.50 20.80 19.00 SDT 75.20 84.40 93.70 102.90 112.10 121.20 130.40 139.60 KW 1.07 1.22 1.37 1.55 1.74 1.97 2.23 2.53 55 (12.78) TCG 33.20 31.50 29.80 28.00 26.20 24.40 22.60 20.70 SDT 76.70 85.80 95.00 104.20 113.30 122.40 131.50 140.60 KW 1.07 1.22 1.38 1.55 1.75 1.97 2.23 2.53 NXA430GKC 30 (1.11) TCG 24.90 23.60 22.30 21.00 19.60 18.30 16.80 15.20 SDT 68.80 78.20 87.70 97.20 106.60 116.00 125.40 134.80 KW 1.22 1.39 1.56 1.74 1.95 2.19 2.47 2.80 35 (1.67) TCG 27.40 26.00 24.60 23.20 21.70 20.20 18.60 16.90 SDT 70.00 79.40 88.80 98.10 107.50 116.90 126.20 135.50 KW 1.23 1.39 1.56 1.75 1.96 2.20 2.48 2.81 40 (4.44) TCG 30.10 28.60 27.00 25.50 23.90 22.20 20.50 18.70 SDT 71.30 80.60 89.90 99.20 108.50 117.80 127.10 136.40 KW 1.24 1.40 1.57 1.76 1.97 2.21 2.49 2.82 45 (7.22) TCG 33.10 31.40 29.70 28.00 26.30 24.50 22.60 20.60 SDT 72.70 81.90 91.10 100.40 109.60 118.90 128.10 137.30 KW 1.24 1.40 1.57 1.76 1.97 2.22 2.50 2.83 50 (10.0) TCG 36.20 34.40 32.50 30.70 28.80 26.80 24.80 22.60 SDT 74.20 83.20 92.40 101.60 110.80 120.00 129.10 138.20 KW 1.25 1.41 1.58 1.77 1.98 2.22 2.51 2.84 55 (12.78) TCG 39.60 37.60 35.60 33.50 31.50 29.30 27.10 24.80 SDT 75.70 84.70 93.80 102.90 112.00 121.10 130.20 139.20 KW 1.25 1.41 1.58 1.77 1.98 2.23 2.52 2.85 NXA436GKC 30 (1.11) TCG 26.10 27.90 27.70 26.40 24.50 22.40 20.20 18.30 SDT 67.10 78.20 88.40 98.00 107.30 116.50 125.70 135.10 KW 1.34 1.73 2.00 2.24 2.48 2.75 3.08 3.51 35 (1.67) TCG 29.80 31.20 30.80 29.30 27.20 24.90 22.60 20.50 SDT 68.60 79.50 89.50 98.90 108.10 117.30 126.50 135.80 KW 1.33 1.71 1.99 2.23 2.47 2.74 3.07 3.51 40 (4.44) TCG 33.60 34.60 33.90 32.20 30.00 27.50 25.10 22.80 SDT 70.00 80.80 90.50 99.80 109.10 118.20 127.30 136.60 KW 1.31 1.69 1.97 2.21 2.46 2.73 3.07 3.50 45 (7.22) TCG 37.30 38.00 37.10 35.20 32.70 30.10 27.50 25.10 SDT 71.40 81.80 91.50 100.80 110.00 119.00 128.10 137.30 KW 1.30 1.67 1.95 2.20 2.45 2.73 3.07 3.50 50 (10.0) TCG 41.00 41.30 40.10 38.00 35.40 32.60 29.80 27.30 SDT 72.60 82.80 92.40 101.70 110.80 119.80 128.90 138.00 KW 1.28 1.65 1.94 2.19 2.45 2.74 3.08 3.51 55 (12.78) TCG 44.50 44.50 43.00 40.70 37.90 34.90 32.00 29.20 SDT 73.70 83.80 93.40 102.60 111.70 120.60 129.60 138.70 KW 1.26 1.64 1.94 2.20 2.46 2.75 3.09 3.53 See notes on page 12 PRODUCT SPECIFICATIONS Split System Air Conditioner: NXA4 12 421 71 6240 05Specifications subject to change without notice. CONDENSER ONLY RATINGS CONTINUED SST °F (°C) CONDENSER ENTERING AIR TEMPERATURES °F (°C) 55 (12.78)65 (18.33)75 (23.89)85 (29.44)95 (35.0)105 (40.56)115 (46.11)125 (51.67) NXA442GKC 30 (1.11) TCG 33.60 32.00 30.40 28.70 26.90 25.00 23.10 21.00 SDT 67.80 77.30 86.90 96.50 106.00 115.50 125.00 134.40 KW 1.73 1.92 2.14 2.39 2.66 2.97 3.31 3.70 35 (1.67) TCG 37.10 35.30 33.50 31.60 29.70 27.60 25.50 23.30 SDT 69.00 78.50 88.00 97.50 107.00 116.40 125.70 135.10 KW 1.73 1.93 2.15 2.40 2.67 2.98 3.33 3.71 40 (4.44) TCG 40.80 38.90 36.90 34.80 32.70 30.50 28.10 25.70 SDT 70.20 79.70 89.10 98.60 108.00 117.30 126.50 135.80 KW 1.74 1.94 2.16 2.41 2.68 2.99 3.34 3.73 45 (7.22) TCG 44.90 42.70 40.50 38.20 35.90 33.50 31.00 28.30 SDT 71.60 80.90 90.30 99.60 108.90 118.20 127.40 136.60 KW 1.74 1.94 2.17 2.41 2.69 3.00 3.35 3.74 50 (10.0) TCG 49.30 46.90 44.40 42.00 39.40 36.70 34.00 31.10 SDT 73.00 82.30 91.50 100.70 110.00 119.20 128.30 137.50 KW 1.75 1.95 2.17 2.42 2.70 3.01 3.36 3.76 55 (12.78) TCG 54.00 51.40 48.70 45.90 43.10 40.20 37.20 34.10 SDT 74.50 83.60 92.80 101.90 111.10 120.20 129.30 138.40 KW 1.75 1.95 2.17 2.42 2.71 3.02 3.38 3.77 NXA448GKC 30 (1.11) TCG 40.80 38.00 35.60 33.50 31.40 29.10 26.60 23.70 SDT 69.00 78.10 87.30 96.60 106.00 115.30 124.50 133.70 KW 2.01 2.38 2.69 2.97 3.28 3.65 4.13 4.75 35 (1.67) TCG 44.70 41.80 39.30 37.10 34.80 32.30 29.50 26.40 SDT 70.30 79.30 88.50 97.70 107.00 116.30 125.40 134.60 KW 1.99 2.37 2.69 2.99 3.30 3.67 4.14 4.75 40 (4.44) TCG 48.90 45.90 43.30 40.90 38.40 35.70 32.60 29.20 SDT 71.70 80.60 89.80 99.00 108.20 117.30 126.50 135.50 KW 1.97 2.36 2.69 3.00 3.32 3.69 4.16 4.76 45 (7.22) TCG 53.30 50.30 47.60 45.00 42.20 39.30 35.90 32.20 SDT 73.10 82.10 91.10 100.30 109.40 118.50 127.50 136.40 KW 1.94 2.35 2.69 3.01 3.34 3.71 4.18 4.76 50 (10.0) TCG 58.10 55.00 52.10 49.30 46.30 43.10 39.40 35.30 SDT 74.70 83.60 92.60 101.70 110.70 119.70 128.60 137.40 KW 1.90 2.32 2.68 3.01 3.35 3.73 4.19 4.77 55 (12.78) TCG 63.30 60.00 57.00 53.90 50.60 47.00 43.00 38.60 SDT 76.40 85.20 94.20 103.20 112.20 121.00 129.80 138.40 KW 1.86 2.30 2.67 3.01 3.36 3.74 4.20 4.77 NXA460GKC 30 (-1.11) TCG 53.80 50.20 47.00 44.00 41.20 38.30 35.20 31.80 SDT 71.80 80.60 89.70 98.90 108.10 117.40 126.50 135.60 KW 3.08 3.18 3.40 3.73 4.14 4.62 5.14 5.69 35 (1.67) TCG 59.10 55.20 51.70 48.60 45.50 42.30 38.80 35.10 SDT 73.20 82.00 91.00 100.10 109.30 118.50 127.60 136.60 KW 3.06 3.17 3.40 3.73 4.15 4.63 5.16 5.71 40 (4.44) TCG 64.70 60.60 56.90 53.50 50.00 46.50 42.80 38.70 SDT 74.70 83.40 92.40 101.40 110.60 119.70 128.70 137.60 KW 3.03 3.16 3.39 3.73 4.16 4.65 5.18 5.74 45 (7.22) TCG 70.70 66.40 62.40 58.70 54.90 51.10 46.90 42.50 SDT 76.30 85.00 93.90 102.90 112.00 121.00 129.90 138.70 KW 3.01 3.14 3.39 3.74 4.17 4.67 5.21 5.77 50 (10.0) TCG 77.20 72.60 68.40 64.30 60.20 55.90 51.40 46.60 SDT 78.20 86.80 95.60 104.50 113.50 122.40 131.20 139.80 KW 2.97 3.12 3.38 3.75 4.20 4.70 5.25 5.81 55 (12.78) TCG 84.20 79.30 74.70 70.30 65.80 61.10 56.10 50.80 SDT 80.20 88.80 97.50 106.30 115.10 123.90 132.50 141.00 KW 2.93 3.10 3.39 3.76 4.22 4.74 5.29 5.86 * AHRI listing applies only to systems shown in Combination Ratings table. KW - Outdoor Unit Kilowatts Only. SDT - Saturated Temperature Leaving Compressor (°F) SST - Saturated Temperature Entering Compressor (°F/°C) TCG - Gross Cooling Capacity (1000 Btuh) PRODUCT SPECIFICATIONS Split System Air Conditioner: NXA4 421 71 6240 05 13Specifications subject to change without notice. ACCESSORY USAGE GUIDELINES Accessory REQUIRED FOR LOW−AMBIENT APPLICATIONS {Below 55°F (13°C)} REQUIRED FOR LONG−LINE APPLICATIONS* Crankcase Heater Yes Yes Evaporator Freeze Thermostat Yes No Winter Start Control Yes**No TXV Yes Yesǂ Hard Start Kit (Capacitor & Relay)Yes Yes Low Ambient Kit (Pressure Switch)Yes No Support Feet, 4” (102mm) tall Recommended No * Refer to the Long Line Application Guideline document. ** Can only be installed in conjunction with the Low Pressure Switch ǂ TXV required beyond 20 ft (6.1m) vertical separation or 50 ft (15.2) total length. ACCESSORIES Accessory Kit Number Description 18 24 30 36 42 48 60 NASA001CH Crankcase Heater for Scroll Compressor X X X NASA003CH Crankcase Heater for Scroll Compressor X X X X NASA001SC Start Component − PTC Device X X X X X X X NASA00201FS Evaporator Freeze Thermostat X X X X X X X NASA404PS High Pressure Switch X X X X X X X NASA403PS Low Pressure Switch, AC, R−410A X X X X X X X NASA401LS Liquid Line Solenoid Valve, R−410A X X X X X X X NASA001TD Time Delay Relay, Indoor Blower X X X X X X X NASA00201WS Winter Start Control X X X X X X X NASA001AC Anti−Cycle Timer (5 minute delay)X X X X X X X NASA404PS High Pressure Switch, AC or HP, R−410A X X X X X X X NASA401LA Low Ambient Kit (Pressure Switch), R−410A X X X X X X X NASA001SJ Sound Jacket, Compressor X X NASA002SJ Sound Jacket, Compressor X X X NASA003SJ Sound Jacket, Compressor X NAEA40501TX TXV Kit for use with copper or tin fan coils X X X NAEA40601TX TXV Kit for use with copper or tin fan coils X X NAEA40701TX TXV Kit for use with copper or tin fan coils X NAEB40501TX TXV Kit for use with aluminum fan coils X X X NAEB40601TX TXV Kit for use with aluminum fan coils X X NAEB40701TX TXV Kit for use with aluminum fan coils X NASA00201SF Support Feet, 4” (102mm) tall (5 blocks)X X X X X X X Copyright 2019 International Comfort Products Lewisburg, Tennessee 37091 USA www.GoICPCommercial.com