HomeMy WebLinkAboutBORAL TILE-updated for review 9.11.20RCIS Home Log In User Registration
. Hot Topics ; Submit Surcharge Stats Ig Facts Publications _ Contact Us BCIS Site Map , Links Search
dbpr
Product Approval
� % USER: Public User
Product Approval Menu > Product or Anplication
Search > Application List n Application Detail
FL #
FL28328-PI
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer Boral Roofing LLC
Address/Phone/Email 7575 Irvine Center Drive
Irvine, CA 92618
(801) 380-6091
robinanderson@boral.com
Authorized Signature Robin Anderson
robin anderson@boral.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Roofing Tiles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 11/03/2020
Validated By Locke Bowden P.E.
� Validation Checklist - Hardcopy Received
Certificate of Independence
FL28328 R1 COI BOR18003.1 2017 FBC Eval Boral Tiles final.pdf
Referenced Standard and Year (of Standard) Standard
ASTM C 1492
TAS 100
TAS 101
TAS 102
TAS 102(A)
TAS 112
Equivalence of Product Standards
Certified By
Sections from the Code
Year
2003
1995
1995
1995
1995
1995
https://www.floridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDqujObYx6FhH7... 9/10/2020
Florida Building Code Online
Page 2 of 3
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
5ummary of Products
r
Method 1 Option D
02/22/2019
02/22/2019
03/02/2019
04/16/2019
FL #
Model, Number or Name
Description
28328.1
Barcelona 900 (Lake Wales)
ASTM C 1492/TAS 112 type la, high profile concrete tile
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL28328 Rl II B01118003.1 2017 FBC Eval Boral Tiles
final.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for lim':ts of use.
Evaluation Reports
FL28328 R1 AE B09,18003.1 2017 FBC Eval Boral Tiles
final.pdf
Created by Independent Third Party: Yes
28328.2
Bermuda (Okeechobee)
ASTM C 1492/TAS 112, type 3a, flat concrete tile
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL28328 R1 1I BOR18003.1 2017 FBC Eva[ Boral Tiles
final.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL28328 RI AE BOR18003.1 2017 FBC Evai Boral Tiles
final.pdf
Created by Independent Third Party: Yes
28328.3 Estate "S" (Okeechobee)
ASTM C 1492/TAS 112 type lb, low profile concrete tile
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL28328 RI II BOR18003.1 2017 FBC Evai Boral Tiles
final.pdF
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL28328 R1 AE BOR18003.1 2017 FBC Eval Boral Tiles
final.odf
Created by Independent Third Party: Yes
28328.4
Galena Spanish "S" (Okeechobee)
ASTM C 1492/TAS 112 type 2a, high profile concrete tile
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL28328 R1 It BOR18003.1 2017 FBC Eval Boral Tiles
final.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party; Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL28328 R1 AE BOR18003.1 2017 FBC Eval Boral Tiles
final.pdf
Created by Independent Third Party: Yes
28328.5 I Ptantation (Okeechobee)
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
ASTM C 1492/TAS 112 type 3a, flat concrete tile
Installation Instructions
FL28328 Rl II BOR18003.1 2017 FBC Eva] Boral Tiles
Final.pdf
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FL28328 R1 AE BOR18003.1 2017 FBC Eval Boral Tiles
final.pdf
Created by Independent Third Party: Yes
28328.6 Saxony 900 Slate, Shake and Split ASTM C 1492/TAS 112, type 3a, flat concrete tile
Shake (Lake Wales and
Okeechobee)
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Installation Instructions
FL26328 RI II BOR18003.1 2017 FBC Eval Boral Tiles
final.odF
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FL28328 R1 AE BOR18003.1 2017 FBC Eval Boral Tiles
https://www.floridabuilding.org/pr/pi_app_dtl.aspx?paramwGEVXQwtDquj ObYx6FhH7... 9/ 10/2020
Florida Building Code Online
Page 3 of 3
final.Ddf
Created by Independent Third Party: Yes
28328.7 Spanish "S Nuevo (Lake Wales)
ASTM C 1492/TAS 112 type 2a, high profile concrete tile
Limits of Use
Approved for use In Hvmz: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Installation Instructions
FL28328 Rl 1I BOR18003.1 2017 FBC Eval Soral Tiles
finaLl
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL28328 RI AE BOR18003.1 2017 FBC Eval Boral Tiles
final..adf
Created by Independent Third Party: Yes
28328.8
Vilia 900 (Lake Wales)
ASTM C 1492/TAS 112 type 1b, low profile concrete tile
Limits of Use
Approved for use in HVHZ: Yes
Installation Instructions
FL28328 R1 11 BOR18003.1 2017 FBC Eva[ Boral Tiles
Final.odf
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Evaluation Reports
FL28328 Rl AE BOR18003A 2017 FBC Fval Boral Tiles
finai.odf
Created by Independent Third Party: Yes
6ac1c Next
Contaa Us :: 2601 81air Stone Road, Tallahassee FL 32399 Pho e: 850-487-1(124
The State of Florida ;San AAIEEO employer. Copyright 2007-2013 State cf Florida.:: privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a publicrecordsrequest, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official comm umcation with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can he made available to the public. To determine if you are a licensee under Chapter 455, F.S., please
oli.k here .
Product Approval Accepts:
M91 _eCheck
Credit Card
Safe
https://NNww.floridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDqujObYx6FhH7... 9/10/2020
MCREEK
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
Bermuda (Okeechobee)
BORAL ROOFING LLC
Concrete Roof Tiles
Prof ileiDescription: ASTM C 1492, TAS 112 Type 3a, flat profile, interlocking, class III concrete roof tile
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 16' x 10"
1-1/T4'
i
16' At
Figure 1. Bermuda
Plantation (Okeechobee)
0—fi r..1n--�;_+;__- A(I-rrkA � 4Ann TA0 44n
CREEK BORAL ROOFING LLC
Concrete oaf Tiles
TECHNICAL. SERVICES, LLC
Saxony 900 Slate, Shake and Split Shake (Lake Wales and Okeechobee)
Profile/Description: ASTM C 1492, TAS 112 Type 3a, flat profile, interlocking, class III concrete roof tile
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 17" x 13" x 1-5I32" (Slate) or 1-9132" (Shake and Split Shake)
N.JJL HOLES
0
NAIL HOLES
tC
MAIL HOLES
a
LNDERLOCI,:
Figure 3. Saxony 900 Slate
Figure 4. Saxony 900 Shake
y L-
Figure 5. Saxony 900 Split Shake
'2" 45Jate)
COVERLOCK
1-9132- (Shake)
01
BOR18003.1 FL28328-R1 Page 4 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CRFFK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
MM
MCREEK
BORAL ROOFING iLC
Concrete Roof Tiles
TECHNICAL SERVICES, LL.0
Estate "S" (Okeechobee)
ProfilelDescription: ASTM C 1492, TAS 112 Type 1 b, low profile, interlocking, class III concrete roof tile
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 16-112" x 13"
Nail Holes I-�--�
Figure 6. Estate
Villa 900 (Lake Wales)
Profile/Description: ASTM C 1492, TAS 112 Type 1 b, low profile, interlocking, class III concrete roof tile
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 17.0" x 13" x 2--118"
21/8"
1
Figure 7. Villa 900
BOR18003.1 FL28328-R1 Page 5 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
BORAL ROOFING LLC
Concrete Roof Tiles
Barcelona 900 (Lake Wales)
Prof ile/Description: ASTM C 1492, TAS 112 Type la, high profile, interlocking, class III, `S' shaped concrete
roof tile
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 17" x 13" x 3-518"
NAIL
OVERLOCK
Figure 8. Barcelona 900
Galena Spanish "S" (Okeechobee)
Profile/Description: ASTM C 1492, TAS 112 Type 2a, high profile, interlocking, class Ili `S shaped concrete
roof tile
Allowable Applications: For mechanically fastened (direct deck), mortar set or adhesive set applications
Dimensions: 17" x 10" x 2.7"
Fastener
Holes
1
17"
10.1
Figure 9. Galena Spanish "S"
BOR18003.1 FL28328-R1 Page 6 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein
CREEK
TECHNICAL SERVICES, LLC
Spanish "S" Nuevo (Lake Wakes)
BORAL ROOFING LLC
Concrete Roof Tiles
Profile/Description: ASTM C 1492, TAS 112 Type 2a, high profile, interlocking, class III `S' shaped concrete
roof tile
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 17" x 9-3/4" x 2-27132"
Fastener Hole
APPLICATION METHOD
L
17"
9-314"
Figure 10. Spanish "S" Nuevo
Installation
Limited to slopes 3:12 or greater in the HVHZ; Outside the HVHZ, shall be in accordance
Slope:
with the recommendations of the FRSAITRI Florida High Wind Concrete and Clay Roof
Tile Installation Manual, Fifth Edition Revised or RAS 118, RAS 119, or RAS 120, as
applicable.
Solid or closely fitted min. 15132-inch plywood sheathing for new and existing construction
Roof Deck:
at max. 24 in. span; In the HVHZ, new construction shall be min. 19132 in. plywood at max.
24 in. span; Designed by others in accordance with FBC requirements.
Underlayment:
Installed in accordance with FBC requirements. In the HVHZ, the minimum underlayment
shall be installed as described in RAS 118, RAS 119, or RAS 120, as applicable.
BOR18003.1 FL28328-R1 Page 7 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shail notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK BOR ROOFING LLC
Concrete Roof Tiles
TECHNICAL.. SERVICES, LLC
Data for Attachment Calculations for Direct to Deck Applications
Nominal Weight (W) and
Aerodynamic
Restoring Moments due to Gravity - M9 (ft-lbf)
Dimensions (I x w)
Multipliers
Direct Deck
Roof Tile
A (ft')
7W (Ib0
I (ft)
w (ft)
Direct Deck
3":12"
4":12"
5":12"
6":12"
>7":12"
Application
Bermuda
9.7
1.33
0.833
0205
6.97
6.86
6.71
6.54
6.35
Plantation
11.6
1.375
1-08
0.289
7.79
7.67
7.52
7.32
7.04
Saxony 900
10.9
1.417
1.08
0.315
7.62
7.5
7.34
7.16
6.95
Estate "S"
10.0
1 375
1.08
0.289
6.74
6.64
6.50
6.33
6.14
Villa 900
10.9
1 A2
1.08
0.315
7.62
7.50
7.34
7.15
6.95
Barcelona
115
1.417
1.08
0.301
7.00
6.90
6.76
6.60
6.42
900
Galena
8.5
1.42
0.833
0.235
6.13
6.03
5.89
5.74
5.57
Spanish "S"
Spanish "S"
8.95
1.417
0.8125
0.233
5.93
5.83
5.70
5.56
5.39
Nuevo
Data for Attachment Calculations for Batten Applications
Roof Tile
Nominal Weight (W) and
Dimensions (I x w)
Aerodynamic
Multipliers
3
(ft )
Restoring Moments due to Gravity - M9 (ft-lbf)
Direct Deck
W (lbf)
I (ft)
w (ft)
Batten
3":12"
4":12"
5":12"
6":12"
>7":12"
Application
Bermuda
9.7
1 33
0.833
0.189
6.53
643
6.29
6.14
5.97
Piantaticn
11.6
1.375
1.08
7
6.85
6.75
6.61
6.44
6.26
Saxony 900
10.9
1.417
1.08
0.291
-
6.61
6.48
6.31
6.13
Estate "S"
10.0
1-375
1.08
0.267
5.91
5.82
5.70
5.56
5.40
Villa 900
10.9
1.42
1.08
0291
-
6.56
6.42
6.26
6.08
Barcelona
11.5
1.417
1,08
0.286
6.19
6.19
6.06
5.92
5.76
900
Spanish °S"
8.95
1.417
0.8125
0.215
5.30
5.21
5.09
4.96
4.82
Nuevo
BOP18003.1 FL28328-R1 Page 8 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein
CREEK
TECHNICAL. SERVICES, LLC
BORAL ROOFING LLC
Concrete Roof Tiles
Attachment Resistance Expressed as a Moment for Mechanically Fastened Applications
Tile Fastener Mr (ft-lbf}
Roof Tile Direct Deck Direct Deck
Type Couanknt Size ShCllp (min.15/32" 1 (min.19/32" Battens
Nail
2
10d
Ring
NIA
30.9
38.1
17.2
Nail
1
10d
Smooth
NIA
7.3
9.8
4.9
or Screw
Nail
2
10d
Smooth
NIA
14.0
18.8
7.4
or Screw
Screw
1
#8
NIA
NIA
30.8
30.8
18.2
Bermuda,
Screw
2
#8
NIA
NIA
51.7
51.7
24.4
Plantation or
Saxony 900
Nail
1
10d
Smooth
S
Field
24.3
24.3
24.2
Screw
Nail
1
10d
Smooth
Eave
19.0
19.0
22.1
or Screw
Nail
2
10d
Smooth
Field
35.5
35.5
34.8
or Screw
Nail
2
10d
Smooth
Eave
31.9
31.9
32.2
or Screw
Nair
2
10d
Ring
NIA
50.3
65.5
48.3
Nail
2
10d
Ring
NIA
2T8
37A
28.8
Nail
1
10d
Smooth
NIA
8 8
11.8
4.1
or Screw
Nail
2
10d
Smooth
NIA
16.4
21.9
7.1
or Screw
Screw
1
#8
NIA
NIA
25.8
25.8
22_9
Estate ,S,,2,
Screw
2
#8
NIA
NIA
47.1
47.1
49.1
Villa 900
Nail
1
10d
Smooth
Field
24.3
24.3
24.2
or Screw
Nail
1
10d
Smooth
Eave
19.0
190
221
or Screw
Nail
2
10d
Smooth
Field
35.5
35.5
34.8
or Screw
Nail
2
10d
Smooth
Eave
31.9
31.9
32.2
or Screw
Estate "S" Nail'
2
10d
Ring
NIA
43.0
67.5
50.9
Continued on following page
BOR18003.1
FL28328-R1
Page 9 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer
shall notify CREEK
Technical Services, LLC of any product
changes or quality
assurance changes throughout the duration
for which this
report is valid.
This evaluation report does not express nor
imply warranty,
installation,
recommended use, or other
product attributes that are not
specifically addressed herein.
0 GREEK
TECHNICAL SERVICES, LLC
BORAL ROOFING LLC
Concrete Roof Tiles
Attachment Resistance Expressed as a Moment for Mechanically Fastened Applications
Tile Fastener
Mr (ft-Ibf)
Roof Tile
Direct Deck
Direct Deck
Type
Count
Size
Shank
Clip
(min.15132"
(min.19/32"
Battens
plywood)
plywood)
Nail
2
10d
Ring
NIA
28.6
41.2
19.4
Smooth
Nail
1
10d
or Screw
NIA
5.1
6.8
2.8
Nail
2
10d
Smooth
NIA
6.9
9.2
7.3
or Screw
Screw
1
#8
NIA
NIA
20.7
20.7
18.1
Barcelona 900,
Galena3 or
Screw
2
98
NIA
NIA
43.2
43.2
29.8
Spanish "S"
Smooth
Nuevo
Nail
1
10d
or Screw
Field
23.1
23.1
19.0
Nail
1
10d
Smooth
Eave
29.3
29.3
24.0
or Screw
Nail
2
10d
Smooth
Field
27.6
27.6
386
or Screw
Nail
2
10d
Smooth
Eave
38.1
38.1
41.8
or Screw
Nail'
2
10d
Ring
NIA
33.1
48.1
45.2
Notes: 1) Not for Saxony 900, Villa 900 or Barcelona 900. Installation with a 4" the headlap and fasteners are located a min. 2-112"
from head of tile.
2) When using only one fastener, use the hole that is approximately 4-3I4" away from interlocking edge.
3) Direct Deck applications only.
Attachment Resistance Expressed as a Moment for Adhesive or Mortar Set
Roof Tile
Adhesive
Product Approval'
Paddy
Count
Average Paddy
Weight (grams)
Mr (ft-lbf)
Dow Chemical TILE BOND7M
NOA 16-0222.01
2
13.9
31.3
Bermuda,
Planation and
Saxony 900
ICP Adhesives Polyset AH-160
NOA 17-0322.03
2
8
31.3
1
24
40.4
1
45
118.9
Saxony 900
DAP Foam Inc. Touch N' Seal®
Storm BondTm 2 Two -Component
NOA 17-0829.12
2
8
59.0
1
24
45
1
45
93
Premix Marbletite, Inc. TILE-TITE
NOA 17-1016.07
NIA
NIA
43.9
Dow Chemical TILE BOND TM
NOA 16-022201
2
11.4
26.1
Estate " S" or
Villa 900
ICP Adhesives Polyset AH-160
NOA 17-0322.03
2
8
26.1
1
24
45.5
1
54
86.61
Premix Marbletite, Inc. TILE-TITE
NOA 17-1016.07
NIA
NIA
20.6
Villa 900
DAP Foam Inc. Touch N' Seal®
Storm BondTm 2 Two -Component
NOA 17-0829.12
2
8
55
1
30
40
1
CO
1 70
BOR18003.1 FL28328-Rl Page 10 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid_
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL, SERVICES, LLC
BORAL ROOFING LLC
Concrete Roof Tiles
Attachment Resistance Expressed as a Moment for Adhesive or Mortar Set
Roof Tile
Adhesive
Product Approval'
Paddy
Count
Average Paddy
Weight (grams)
Mf (ft-lbo
Dow Chemical TILE BONDT"'
NOA 16-0222.01
2
10.7
29.3
Barcelona 900,
Galena Spanish
"S" or Spanish
"S" Nuevo
ICP Adhesives Polyset AH--160
NOA 17-0322,03
2
8
29.3
1
24
38.7
1
63
66.5
Premix Marbletite, Inc. TILE-TITE
NOA 17-1016.07
NIA
NIA
24.5
Barcelona 900
DAP Foam Inc. Touch N' Seal®
Storm BondTm 2 Two -Component
NOA 17-0829,12
2
8
66.0
1
30
63
1
60
82
Notes: 1) See manufacturer's product approval for installation requirements.
LABELING
1) All tiles shall bear the identifiable marking of the manufacturer's name or logo as follows:
Manufactured in Lake Wales, FL
Manufactured in Okeechobee, FL
OR
7�7 ENTE RA v�7
BOR18003.1 FL28328-RI Pagel 1 of 12
This evaluation report is provided for State of Florida product approval under Rule 6tG20-3. The manufacturer shall. notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
BORAL ROOFING LLC
Concrete Roof Tiles
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Installation of the evaluated products shall comply with FBC Section 1507.3, FRSAITRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Fifth Edition Revised and the manufacturers published
application instructions. Installations in the HVHZ shall comply with RAS 118, RAS119 and RAS 120,
3) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
4) All product listed in this shall tested quarterly in accordance with TAS 112 Appendix A.
5) Installation of the evaluated products shall be limited to projects in areas subjected to weathering indices of
50 or greater as illustrated in ASTM C 1492-03, figure 1 (see below).
5D
50 50
WEATHERING REGIONS
NEGLIGIBLE WEATHERING
MODERATE WEATHERING
7t:
SEVERE WEATHERING
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R Priest P.E have demonstrated compliance with the Florida Building
Code, 61h Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
R.
C'? •� G•E•N S • 7F�' �'
ti ; •� F• I
a �
nz
No 74021
�9 •• STATE OF •:�
S1ONA` �.`.
CERTIFICATION OF INDEPENDENCE
2019.02.1
9 10:10:22
ros'ool
Zachary R. Priest, P E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services; LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
BOR18003-1 FL28328-R1 Page 12 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use. or other product attributes that are not