HomeMy WebLinkAboutBuilding PlansPANIC HARDWARE DEVICE NOT REQL IRED 1 1 AT THIS DOOR PER NFPA 13.2.2.2.3 BECAUSE INSTALL PANIC HARDWARE OCCUPANT LOAD EXITING AT THIS LOCATION DEVICE ON EXISTING DOOR IS LESS THAN 100 9 FE 9 FE (STINGe45(360) O EXISTING EQUIPMENT T FREEZER ROOM EXISTING EXISTING 6(180) STORAGE STORAGE 9 O EXISTING EXISTING m EXISTING MEWS MEN'S COOLER RR RR EXISTING W �` C KITCHEN a EXISTING EXISTING - CORRIDOR 2,416 S.F. = 12 OCC. o _ CORRIDOF w I 200 S.FJ000. J 1 1 1 z / o ¢ fb- Ot a a o� ° z ¢ 0 EXISTING EXISTING r WOMEN'S WOMEN'S -------- - -- RR RR O EXISTING N 9 COOLERLn T x 139(360) $14" A.F.F. T.O.PLATFORN NEW FE PLATFORM IL NEW PLATFORM NEW ACCESSIBLE PLATFORM E---139(180) DOOR HAS EXISTING PANIC HARDWARE DEVICE. 1 o —— I I 1 I IJ o IJ o REMODELED BAR AREA 9 9 39(180) 38(180) EXISTING EXISTING DINING ROOM LOBBY 1,154 S.F. - 77 OCC. 15 S.FJ000. FE J z Q INSTALL PANIC HARDWARE ? Z DEVICE ON EXISTING DOOR < 139(360) o EXISTING VESTIBULE t� X ❑❑ n 1 ❑ ❑ w 02 LIFE SAFETY PLAN SCALE: 118" =1'-0" 41" A.F.F TO PLATFORM 33" A.F.F. T.O. PLATFORM -O23" A.F.F. -T.O.PLATFORM �1 ° A.F.F. T�O. PLATFORM N a FE O FE EXISTING EXIST. ELECT. PANELS EXISTING EQUIPMENT FREEZER ROOM 0 0 - - - � LINE OF MEZZANINE ABOVE - - - -- EXISTING EXISTING COOLER KITCHEN L7 � EXIST. STAIR TO Leo• o STORAGE MEZZANINE r--------------- - - - - -- EXISTING WALL, TYP. t 1 'll — 11 11 COOLER EXISTING / / SERVING AIEA BUILDING CODE INFORMATION BASED ON FLORIDA BUILDING CODE 2010 BUILDING TYPE: TYPE IS CONSTRUCTION, SPRINKLERED TENANT AREA:10,382 SF OCCUPANCY: GROUP A-2, ASSEMBLY OCCUPANT LOAD: ASSEMBLY: 6,259 SF115 SF PER OCC = 417 KITCHEN: 2,416 SF/200 SF PER OCC =12 TOTAL = 429 OCCUPANTS LEVEL OF ALTERATION (PER EXISTING BUILDING CODE):LEVEL 2 EXIT REQUIREMENTS: Dead end limit -maximum condition 20 Feet Travel distance to exit -maximum condition 250 Feet SPECIFIC NOTES 1. EVERYTHING IS EXISTING UNLESS NOTED OTHERWISE. SCOPE OF WORK INCLUDES BAR AREA REMODEL, CONSTRUCTION OF PLATFORMS, RE -PAINTING AND NEW TILE FLOORING. 2. EXISTING ROOF STRUCTURE CONSISTS OF METAL DECK OVER STRUCTURAL STEEL JOISTS. 3. EXISTING MEZZANINE SHALL BE USED FOR STORAGE ONLY. AND SHALL NOT EXCEED AN OCCUPANT LOAD OF 5 PEOPLE AT ANY GIVEN TIME. 4. ALL MECHANICAL SYSTEMS ARE EXISTING TO REMAIN. 5, FIRE SPINKLER SYSTEM IS EXISTING TO REMAIN, GENERAL' NOTES 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL LOCAL AND APPLICABLE CODES & FBC 2010. 2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS AND REGULATIONS OF THE BUILDING STANDARDS AND LOCAL JURISDICTIONS. 3. ALL FINISH MATERIALS, HARDWARE, ETC. SHALL MATCH THE BUILDING STANDARDS UNLESS NOTED OTHERWISE, IF THE CONTRACTOR HAS DIF- FICULTY MATCHING BUILDING STANDARDS HE/SHE SHALL OBTAIN THE ARCHI- TECTS APPROVAL PRIOR TO SUBSTITUTING ANY ITEMS. 4. PROPER CARE AND PROTECTION SHALL BE PROVIDED FOR ALL AREAS ADJACENT TO CONSTRUCTION AND ANY DAMAGE THAT MAY OCCUR TO THESE AREAS AS A RESULT OF THIS CONSTRUCTION SHALL BE PROMPTLY REPAIRED BY THE CONTRACTOR TO THE ORIGINAL CONDITION. 5. ANY WORK THAT MUST BE PERFORMED IN OTHER SPACES IN RELATION TO THIS CONSTRUCTION SHALL BE PERFORMED IN A MANNER 50 AS NOT TO DISRUPT THE OCCUPANT, ALL WALLS, SLABS, CEILINGS, ETC. DISTURBED IN OTHER SPACES SHALL BE RESTORED TO ORIGINAL CONDITION ONCE WORK IS COMPLETE. 6. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL REVIEW THE CONTRACT DOCUMENTS AND VERIFY ALL EXISTING CONDITIONS AND THEIR COMPATIBILITY WITH THE NEW CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 7. EXISTING FIRE RATINGS SHALL BE MAINTAINED AT SLAB PENETRATIONS RATED WALLS, RATED CEILING ASSEMBLIES AND FIRE COMPARTMENT ZONES. S. EXISTING FIRE RATINGS SHALL BE MAINTAINED AT SLAB PENETRATIONS RATED WALLS, RATED CEILING ASSEMBLIES AND FIRE COMPARTMENT ZONES. LIFE SAFETY NOTES t OCCUPANCY TYPE SHALL BE ASSEMBLY GROUP "A-2". 0 2. FIRE STOPPING AND DRAFT STOPPING SHALL BE PROVIDED AT ANY NEW STAIRS CONCEALED SPACE IN WHICH EXPOSED MATERIAL HAS A FLAME - SPREAD RATING LESS THAN CLASS -A. RATED ASSEMBLIES 3, FIRE RATED WALL ASSEMBLIES SHALL EXTEND FULLY FROM THE FLOOR TO THE STRUCTURE & DECK ABOVE, ALL PENETRATIONS OF RATED ASSEMBLIES SHALL BE PROTECTED PER NFPA 101, BY FIRE DAMPERS, SLEEVES OR FIRE CAULKING BY A U.L. APPROVED METHOD. - EXISTING 4. PROVIDE UL RATED SYSTEM AT ALL PIPE, DUCTWORK, STRUCTURAL STEEL DINING AREA AND METAL JOIST PENETRATION OF FIRE -RATED WALLS. 5. BUILDING EXIT DOORS REQUIRED BY CODE SHALL HAVE PANIC DEVICES AND SWING IN THE DIRECTION OF EGRESS, TYP. PLATFORM FR6WNG: < REQUIREMENTS %" PLYWOOD ON 2X4WOOD STUD o 6. ALL CORRIDORS AND NORMALLY OCCUPIED ROOMS WALLS @ 16" O.C. W1 STUD SPACING SHALL BE EQUIPPED WITH EMERGENCY LIGHTING. @ 24" O.C. MAX (SEE DETAIL 10IA-2 FOR ADDTL INFO) EXIST. STEEL COLUMN, TYP. 7. FIRE EXTINGUISHERS SHALL BE PLACED AT INTERVAL NOT EXCEEDING A TRAVEL DISTANCE OF 75'. i L/8.PROVIDE A VOICE EVACUATION FIRE ALARM SYSTEM ASUIRED BY THE FLORIDA FIRE PREVENTION CODE & A 101 UNDER SEPARATE PERMIT. 01 & 021A-2 LIFE SAFETY SYMBOLS LEGEND I � I o I o EXISTING TWO HOUR FIRE RATED WALL, ALL REMODELED ( OPENINGS AND MECHANICAL PENETRATIONS Fp BAR AREA I SHALL BE PROTECTED TO MAINTAIN THE INTEGRITY OF THE FIRE RATING FOR THE WALL. 031A-2 - - - - 1 - - P PRIMARY MEANS OF EGRESS NEW RAMP 6'.4' - - 274' e EMERGENCY EXIT LIGHT FE o N WALL HUNG FIR E EXTINGUISHER FE THESE PLANS AND ALL PROPOSED WO 4K — OCCUPANT LOAD ARE SUBJECT TO ANY CORRECTION XXX(XX1 REQUIRED BY FIELD INSPECTORS TH 1 T OPENING EGRESS CAPACITY F I LE MAY BE NECESSARY IN ORDER TO EXISTING COMPLY WITH ALL APPLICABLE CODE EXISTING DINING ROOM LOBBY S'T', LUCIE COL: Y tYltlr, USY-T21C'i- EMERGENCYLIGHTS REVIEWED FO CON, 2LIANCE SUBJECT'TO FI LD INS =DONS SEE ATTAC) S N SAE 01 OVERALL FLOOR PLAN SCALE: 118" = i' 0' UYPLAN NOT TO SCALE REV # DATE 10 11-25-2013 z 0 Q LL w V) z LLJ LJ.J � LLI�� W �Q cY) 0 P v (D U- LLI Z � V z F— On H- 0 Q z = ' g� ~ H- W I- v Z 0 z 0� I.L O V) w M V �+ `O M 0) LO E L W Ln tM CO CD M O Q J (D U -0LL N � N Cn E (3 M M CL U Cn CU 0- DRAWN BY SDC CHECKED BY SDC DATE 9-13-2013 SCALE AS NOTED JOB # 213005 SHEET# A. 5 o BANK VACANT <�+ 7' HIGHx= FD.I.R.& C. <° FD. CONIC, WALL „ p 4„x " S 89'49 00 E 400. Q C.M. CONC.POLE p�-CONC.POLE w per-CONICPOLE FI N.I.S.- 0.M391111.43'N: HYD. P. O.H.W. W ED w P.P. r CONIC 50.44' P.P. ASPHALT DRIVE & PARKING N, BUILDING UNDER CONSTRUCTION 7'HIG $ .. CON A DESCRIPTION:( WARRANTY DEED OFFICIAL RECORDS BOOK 2846, PAGE 775, ST LUCIE COUNTY, FLORIDA) WALL �I 13. 0 3 BEGINNING AT THE SOUTHEAST CORNER OF THE NORTHEAST 1/4 OF THE NORTHWEST 1/4 OF SECTION 22, e( msLAe o a TOWNSHIP 36 SOUTH, RANGE 40 EAST, RUN SOUTH 27 DEGREES 38' EAST, 210 FEET TO THE NORTH LINE `� V °`P o P�' 10.00 m OF RIO MAR DRIVE; THENCE RUN SOUTH 62 DEGREES 22' WEST ALONG RIO MAR DRIVE 30 FEET; THENCE P5v m I� D.H.W. RUN NORTH 27 DEGREES 38' WEST, 225.83 FEET; THENCE RUN NORTH 89 DEGREES 49' WEST, 555.72 FEET o I SET NAIL & TO THE SOUTHWEST CORNER OF THE HEREIN DESCRIBED PARCEL, SAID SOUTHWEST CORNER BEING LOCATED 8 Q FD. NAIL 164 89'(C.) DISK NORTH 89 DEGREES 49' WEST OF AND 589.64 FEET DISTANT FROM THE POINT OF BEGINNING; THENCE FROM �& DISK 164.04'(D.) SAID SOUTHWEST CORNER, RUN NORTH 00 DEGREES 07' EAST, 800.00 FEET; THENCE RUN SOUTH 89 DEGREES 5.99' 49' EAST, 400.00 FEET; THENCE RUN SOUTH 00 DEGREES 07' WEST, 150.00 FEET; THENCE RUN SOUTH 89 S 89'49'00'E-158.90(M.)(C.)I DEGREES 49' EAST, 164.04 FEET TO THE WESTERLY RIGHT OF WAY LINE OF U.S. HIGHWAY NO. 1; THENCE 20.05• S 04'50'08" W RUN SOUTHEASTERLY, ALONG SAID RIGHT OF WAY LINE, BEING A CURVE CONCAVE TO THE NORTHEAST TCHAIN LINK HAVING A RADIUS OF 1952.08 FEET AND AN ARC DISTANT OF 310.62 FEET, THE CHORD OF SAID CURVE FENCE o 27.65' o ASPHALT DRIVE & PARKING ( SET. NAIL BEARS SOUTH 12 DEGREES 00' 05" EAST, SAID CHORD BEING 310.29 FEET; THENCE RUN NORTH 89 CO c z $ & DISgEK� 50 0 50 100 150 DEGREES 49' WEST, 101.01 FEET; THENCE RUN SOUTH 00 DEGREES 07' WEST, 229.94 FEET; THENCE o ADIAL BEARIR� - RUN SOUTH 27 DEGREES 38' EAST, 132.02 FEET TO THE POINT OF BEGINNING. CONIC. TRAFFIC DIVIDER a IN $1'45'24"E it TOGETHER WITH THE RIGHTS ESTABLISHED IN THE INSTRUMENTS RECORDED IN O.R. BOOK 312, PAGE 80.00' I 0 1621; O.R. BOOK 312, PAGE 1611 AND O.R. BOOK 744, PAGE 1010, PUBLIC RECORDS OF ST. LUCIE' 2 88' sD ON °D cuesC' Scale 1 ' - 50' COUNTY, FLORIDA. �B CURBED GRASS SAID LANDS SITUATE IN UNINCORPORATED ST. LUCIE COUNTY, FLORIDA. & ISLAND TRAFFIC OLD R/W LINE OF a DIVIDER U.S. HIGHWAY N0.1 (n oL.P. (TYPICAL) a L. N G a 7 s o -R,/W LINE PER F.D.O.T. R/W Q= A MAP SECTION 94010-2500 O ASPHALT PARKING AND DRIVE 24' z w S1QQ �" ( JULY 2001) ,�� 0. z (PARKING SPACES NOT DELINEATED) �� POLES ICE w 1 Z 0m \\\VVv\\\ HOUSE a o 2.81' Sow > O opy O SB x <z Irn� �� Q ^ a m - RADIUS 1952.08 (f) O ELECTRIC a v Z ARC = 310.62' Z SURVEYOR'S NOTES: O c NC. 25` EOUIP. c POTABLE (n d P P. CONIC � WA1ER DISPENSING n 1 C.B.-S 12'00*05"E 1. ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY OTHER THAN THE SIGNING PARTY IS _ 570014 O N CHORD DISTANCE - 310.29' �..P SLAB Z ul PER DEED) PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE SIGNING PARTY. ( 5J-17 F.A.C. ) IRE ; (/ ` III��� 2.) THIS SURVEY AND RESULTANT DRAWING IS NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL s YD ' SEAL OF THE FLORIDA LICENSED SURVEYOR AND MAPPER. ( 5J-17 F.A.C.) 59.92' Y m 'v 3.) THE BASE OF BEARINGS UTILIZED HEREON IS THE PROPERTY DESCRIPTION PROVIDED, MORE m o \ SPECIFICALLY THE SOUTH BOUNDARY LINE WHICH BEARS NORTH 89 49 00 WEST ALL 7. HIG g coNc. TRAFFIC DIVIDER N OTHER BEARINGS ARE RELATIVE THERETO. C NC. ELECT. (TYPICAL) 1;It711,1r�1`�fft », 4. THIS SURVEY WAS COMPLETED WITHOUT THE BENEFIT OF A FULL SEARCH OF THE PUBLIC RECORDS. V ALL W EOUIP. N _ 5.02' 30' ` L P \ G THERE MAY EASEMENTS, RIGHTS OF WAY AND/OR RESTRICTIONS OF RECORD NOT DELINEATED z I= ^pp�N .ASPHALT ENTRANCE ROAD ON THIS DRAWING o a �5.02 -2d INGRESS/EGRESS RPp\P 0 2 ELECTRONIC DATA IS TRANSMITTED FOR YOUR CONVENIENCE AND IS THE SOLE PROPERTY OF C.A. o I� ns ''� _ - 5.) ELEC o 12 c' FD. EASEMENT - MITCHELL AND ASSOCIATES, INC. BY ACCEPTING DELIVERY HEREOF, THE RECIPIENT HEREBY AGREES `.d 1Qn � Chi TO INDEMNIFY AND HOLD C.A. MITCHELL AND ASSOCIATES, INC., HARMLESS FROM ANY LIABILITY Qo n> 'v 24 DISK N 9� 9'OO"W 12.53' I RESULTING FROM THE USE OF THIS DATA. ELECTRONIC DATA IS SUBJECT TO CHANGE AND Z D D Nm� _ FD. NAIL & COORDINATION OF UPDATES IS THE RESPONSIBILITY OF THE RECIPIENT. INFORMATION CONTAINED 1 89.22'(M.)(C.) ON THE DIGITAL COPY OF ANY DRAWING IS NEITHER CERTIFIED BY C.A. MITCHELL AND ASSOCIATES, INC., n o A DISK no� zs 11.4o I 101.01'(D.) NOR INTENDED TO TAKE THE PLACE OF A CERTIFIED SURVEY, DRAWINGS OR DOCUMENTS. THE ONLY I� W I 101.75'(C.) OFFICIAL DEPICTION OF THIS INFORMATION IS THE ORIGINAL GRAPHIC DRAWING_ ON FILE IN OUR OFFICE _ o OR A VALID SIGNED AND SEALED COPY. UNDER NO CIRCUMSTANCES WILL ANY OTHER GRAPHIC OR 8 01 DIGITAL FORM OF THIS INFORMATION SUPERCEDE IT. m A N o N p 6.) THIS SITE IS LOCATED 1N FLOOD ZONE "X", PER F.E.M.A. FLOOD INSURANCE HATE MAP NUMBER �� 18' � a 12111CO280J, EFFECTIVE DATE OF FEBRUARY 16, 2012, ASPHALY DRIVE PARKING i v 7.) THERE ARE SELECTED EXISTING FEATURES LOCATED ON THIS PROPERTY THAT ARE NOT SHOWN ON THIS SURVEY. THEY INCLUDE SANITARY SEWER MANHOLES, DRAINAGE BASINS, GROUND LEVEL VALVES �� AND UTILITIES. THERE ARE UNDERGROUND WIRES, DUCTS. PIPES, CULVERTS CONDUIT ETC. WHICH ARE g� NOT SHOWN ON THIS SURVEY. f 30' ANCHO 11.5' w 1 71.02' o ' n „1 I SB CONc w a O a 'SLAB o s a t . CONIC j Q dS a _ .... _.. P P. 30 ------ CURBED w 0 Q ISLAND (9. ¢ • Z y �,�• PARKING W x O - ... 1 DIVIDERS. w Q ? ; -i ASPHALT DRIVE --/ (TYPICAL) a N 0] 1 o FD. NAIL &DISK FR lit At (1 AVE C. A. MITCHELL AND ASSOCIATES, INC. °NIPS1I fit` 'PEAR // FIRE HYD. COVERED CONCRETE WALK cn I I �1����� ( CERTIFICATE OF AUTHORIZATION NO. 4276)o. N 23''S' i: 1 i t ESTABLISHED 1985 �ZE W o 28 g 8 0.42 yfSj h,4ty 1 STORY COMMERCIAL BUILDING Lr r ACT&' GRASS 74.87 \ • OD m CHA IN " " LINK � 3g.e5• 8 Off. Va FD. 4 X4 I FENCE ASPHALT DRIVE �0 6g I - CONCRETE MONUMENT 49.77• C� LEGEND: SET pa s'cHAly Nw 72.70' coNc: r FD. = FOUND LINK au w \ a.E CORNER OF THE N.E. 1/4 OF THE FENCE J N N N w cuaBlNc N.W. 1/4 OF SECTION 22, TOWNSHIP 36 I.R.& C. = IRON ROD AND CAP I.R.& C. O.H.W. OD w ASPHALT DRIVE PP. ANCHOR ED 4. i.3 w BST \ z SOUTH, RANGE 40 EAST. (P.) PLAT 33.92' POINT OF BEGINNING FOR DESCRIPTION �, = DCALDCULATED JULY 10, 2013 s'CHAIN LINK 11011RECORDED IN OFFICIAL RECORDS BOOK (C.) ��(M.) MEASURED I� R&; C N 89 49 00 W 555.72 FENGE SET 2 Lit 2846, PAGE 775, ST. LUCIE COUNTY, FLORID, r ^ 0. OHW = OVERHEAD WIRES CLI A. MITCHELLNAIL & 2 ��s a R/W = RIGHT OF WAY .EGEFED LAND SURVEYOR AND MAPPER \-SOUTHWEST CORNER of DESCRIBED PARCEL DISK �� 711 PP .per C/L =CENTERLINE N 89'49' W, 589.64' FROM POINT OF BEGINNING c =-FU*1fA= REGISTRATION N0. 3541 ( SINCE 1982) HOUSE FPL - FLORIDA POWER & LIGHT VACANT � �cA. ��ss's �� BST =BELL SOUTH TELEPHONE cs ® 9 O P.P. =POWER POLE 1 2c^ 0s 9P` 00. L.P. = LIGHT POLE CA = CENTRAL ANGLE DRAWN BY: C.A.M. APPROVED BY: M.E DATE: JULY 11, 2013 PRa, NO, 4585 4585 DWG. File name: C: ,EPSA\4585 REVISIONS F � ° C.M. _ CONCRETE MONUMENT ti SB SETBACK TO PROPERTY LINE v CONIC, = CONCRETE CATV CABLE TELEVISION N.I.S. = NOT IN SERVICE as 4'HIGH CONC WALL FD. I.R. SET- NORTH LINE RICE MAR DRIVE NAIL & DISK P.P S 62'22'00"W O.H.W. 30.00' PROJECT _ SHT. NAME Sm. NO. C.A. MITCHELL AND ASSOCIATES, INC. EXISTING SAINT LUCIE PLAZA SHOPPING CENTER ONE a Sys LAND SURVEYOR'S AND MAPPERS GEOMATIC CONSULTANTS BOUNDARY SURVEY KITH IMPROVEMENT LOCATIONS of 7cn c ui CnI ITI.I LAAnC'hn 00111 CAOAIDF) 00PT cT I I ICIG FI Y1RITIA 'iAQRi ONE TENANT IMPROVEMENTS FOR:MINOR TESO.' t NIGf-I�.-,"TC Rt �'� f Gyro 1i . 3J Y 7159 S. US HIGHWAY 1 PORT ST. LUCIE, FL 34952 :ARCHITECT: stephan daren architect 1445 SW Sandpiper Way Palm City, Florida 34990 Tel.: 772-260-3951 MEP ENGINEER: Jones & Conde, LLC - 4440 PGA Boulevard Palm Beach Gardens, Florida 33410 Tel.: 561-309-9017 w.. Nfrintyll4ilo�MIN. a _ F' „ '� }t drifniliYu d dd'd tld i t �[ r I ��1i 1 i5 Vi mw 1 is k r i �tk r't-� lfl l iv dsrY ili7u{1r,�tit^ r* '1"10 f2TWf r r 99�rMT ' Y rr r�i f!f!f! e : RRWE if . tl ; :i; _ to a .� ..'' mn...u.t .ra _ fn . q ifif F jYierp �.. l ,r,� i4"P r'r4i j1 i >+ `k�j�' [(".z-z�-� a - Yufi it YBiii 31TIM fdl e °� id 9 Ik o�r iir@rr P r a, rd er P .. i' '.. r == a Yl,ii Y19Y l fffiHH Yr ':Iii3I�I� .11E(Eilia� I Fl�lj�aii , ii. fi v, „.,�.n +s�^me� a.``- r r r. CO, -STY FIRE DISTRICT S� S6i98 �a 999e ili9P�P��{!v r{ i r P{ i� q n f m� �r CTE CI. 5T. LL p VLPLIAN + pp ,...,t C .............�.,. � N D O VI PE S _ ., ......__. _ .. _.. LD L� �i�i wmr s S s PATE: _hit/.30 e' L ATI N MAP St LUCIE COUNTY oc o PL AN RE VIEW NOT TO SCALE DRAWING INDEX ARCHITECTURAL A-1 OVERALL FLOOR PLAN, LIFE SAFETY PLAN & NOTES A-2 ENLARGED PLANS & DETAILS ELECTRICAL & PLUMBING ME-1 ELECTRICAL & PLUMBING PLANS, NOTES & DETAILS ELEC: DATE: PLUM : 3 DATE: MECH: DATE:_ i 9 FE e I O 4 FE EXISTING 145(360) EXISTING EQUIPMENT FREEZER ROOM EXISTING 6(180) STORAGE 9 -- - 1 6(360) __- — - — -- — EXISTING "� MEWS m EXISTING m RR a COOLER EXISTING w KITCHEN a a EXISTING — CORRIDOR 2,416 S.F. _ 12 OCC. > 200 S.F.1000. - I To o� 0L_ 0 EXISTING RR - - - -� 0 I EXISTING _LLq9 I COOLER NEW 139(360) �E PLATFORM EXISTING DINING AREA NEW PLATFORM w U 5,105 S.F. 15 STJOCC. - 340 OCC. U Q NEW N ACCESSIBLE PLATFORM Unil REMODELED ® BAR AREA m 'it— 139(180) FE rQ-9i e e 39(180) 38(180) EXISTING EXISTING DINING ROOM LOBBY 1,154 S.F. = 77 OCC. 15 S.F./OCC. 9 r _q�14" A.F.F. T.O. PLATFORM 4 N 41' A.F.F. T.O. PLATFORM i M1 �33"A.F.F. T.O. PLATFORM 23' A.F.F. T.O. PLATFORM J ,i.114" A.i .F V T.O. PLATFORM I o N ■ WALL, TYP. I ••r 'I �11 ••II� n • �i �I �FE 74<wz� a_iooi�am o N 02 0 -BUILDING CODE INFORMATION BASED ON FLORIDA BUILDING CODE 2010 I I BUILDING TYPE: FE EXISTING TYPE IIB CONSTRUCTION SPRINKLERED EQUIPMENT ROOM TENANT AREA: 10,382SF .00CUPANCY: GROUP A-2, ASSEMBLY - OCCUPANT LOAD: ASSEMBLY: 6,259 SF115 SF PER OCC = 417 O KITCHEN: 2,416SF/200 SF PER OCC =12 TOTAL = 429 OCCUPANTS - -- -- -- -- — LEVEL OF ALTERATION (PER EXISTING BUILDING CODE): LEVEL 2 EXIT REQUIREMENTS: EXISTING Dead end limit -maximum condition 20 Feet COOLER Travel distance to exit -maximum condition 250 Feet SPECIFIC NOTES 1 EVERYTHING IS EXISTING UNLESS NOTED OTHERWISE. SCOPE OF WORK INCLUDES BAR AREA REMODEL, CONSTRUCTION OF PLATFORMS, RE -PAINTING AND NEW TILE FLOORING. 0 2. EXISTING ROOF STRUCTURE CONSISTS OF METAL DECK OVER STRUCTURAL STEEL JOISTS. - 3. EXISTING MEZZANINE SHALL BE USED FOR STORAGE ONLY. AND SHALL NOT EXCEED AN OCCUPANT LOAD OF 5 PEOPLE REV #_i DATE AI i i F_ L 0 LL co V) H Z w LL0 EXISTING AT ANY GIVEN TIME. W -t COOLER ,,�( Q M 4. ALL MECHANICAL SYSTEMS ARE EXISTING TO REMAIN. W W > J LL 5. FIRE SPINKLER SYSTEM IS EXISTING TO REMAIN. ® m � LLI d NE � —i � J ~ 0 0 NEW STAIRS EXISTING DINING AREA TYP. PLATFORM FRAMING, %" PLYWOOD ON 2X4 WbOD STUD 0 WALLS @ 16" O.C. W1 STUD SPACING @ 24" O.C. MAX (SEE DETAIL 101A-2 FOR ADDTL INFO) EXIST. STEEL COLUMN, TYP LIFE SAFETY NOTES 1, OCCUPANCY TYPE SHALL BE ASSEMBLY GROUP "A-2" 2. FIRE STOPPING AND DRAFT STOPPING SHALL BE PROVIDED ATANY CONCEALED SPACE IN WHICH EXPOSED MATERIAL HAS A FLAME - SPREAD RATING LESS THAN CLASS -A. RATED ASSEMBLIES 3. FIRE RATED WALL ASSEMBLIES SHALL EXTEND FULLY FROM THE FLOOR TO THE STRUCTURE 6 DECK ABOVE. ALL PENETRATIONS OF RATED ASSEMBLIES SHALL BE PROTECTED PER NFPA 101, BY FIRE DAMPERS, SLEEVES OR FIRE CAULKING BY A U.L. APPROVED METHOD. 4. PROVIDE UL RATED SYSTEM AT ALL PIPE, DUCTWORK, STRUCTURAL STEEL AND METAL JOIST PENETRATION OF FIRE -RATED WALLS. 5. BUILDING EXIT DOORS REQUIRED BY CODE SHALL HAVE PANIC DEVICES AND SWING IN THE DIRECTION OF EGRESS. REQUIREMENTS 6. ALL CORRIDORS AND NORMALLY OCCUPIED ROOMS SHALL BE EQUIPPED WITH EMERGENCY LIGHTING. 7. FIRE EXTINGUISHERS SHALL BE PLACED AT INTERVAL NOT EXCEEDING A TRAVEL DISTANCE OF 75'. — LIFE SAFETY SYMBOLS LEGEND EXISTING TWO HOUR FIRE RATED WALL. ALL OPENINGS AND MECHANICAL PENETRATIONS SHALL BE PROTECTED TO MAINTAIN THE INTEGRITY OF THE FIRE RATING FOR THE WALL. P PRIMARY MEANS OF EGRESS e EMERGENCY EXIT LIGHT WALL HUNG FIRE EXTINGUISHER O 1 OCCUPANTLOAD XXX(XX) T OPENING EGRESS CAPACITY u EMERGENCY LIGHTS FACE COpk _1 UYNAN ilk NOT TO SCALE 4 = LO Z W ,^ v_77 D_ W' L z 0 Lr O F_ I _II 00 >+ O r V Lc0 >M Or)LO 0 ^ � LO > M U W i M V c- 0) : o V 07 N E M LID _CU N U DRAWN BY SDC CHECKED BY SDC DATE 9-13-2013 SCALE AS NOTED JOB # 213005 SHEET# A- I I , o EXIST. CEILING TO REMAIN 11 2'4" 1' 0" + EXIST. WALL TO REMAIN (3)11" TREADS 1%"DIA, 34" H. HANDRAIL MODIFY EXISTING WALL TO ACCOMODATE NEW OPENINGS NEW BAR TOP a4„ HARDWOOD TREAD & RISER 23"AF.F. T.O. PLATFORM 07 INTERIOR ELEVATION ," PLYWOOD GLUED & SCREWED SCALE:1/4" = V-0' 4„ 2x4 WD STUD WALL @ 16" O.C. WI STUD SPACING @ 24" O.C. " + 0'_p" aa: ° ° FIN. FLOOR EXIST. CEILING TO REMAIN EXIST. CONC. SLAB EXIST. WALL TO REMAIN 2X12 WD STRINGER @ ENDS & 16" O.C., MAX I 11 STAIR SECTION - o CUT DOWN PORTION OF EXIST. WALL NEW CAP ON EXIST. WALL Z4 Eo TREADS %" DIA, 34" H. HANDRAIL 08 INTERIOR ELEVATION SCALE:1/4" = V-0" o N "HARDWOOD DEMOLITIONPLAN KEY NOTES — — EXISTING TO BE REMOVED EXISTING TO REMAIN OREMOVE PORTION OF EXISTING WALL TO ACCOMODATE NEW PASS -OPENING PER PROPOSED PLAN. OREMOVE PORTION OF EXISTING WALL AS SHOWN ON INTERIOR ELEVATIONS OREMOVE EXISTING CABINET, COUNTERTOP & SHELVING, REMOVE EXISTING SINK RELOCATE PLUMBING TO OACCOMODATE NEW KITCHEN LAYOUT AS SHOWN ON PROPOSED PLAN. OREMOVE EXISTING FLOOR FINISH & PREP SLAB TO RECEIVE NEW FINISH. OREMOVE EXISTING EQUIPMENT AND TERMINATE UTILITIES AS REQUIRED. ORELOCATE EXISTING VENT PIPE AS SHOWN ON PROPOSED PLANS. 1'4- EQ 1'4EQ P-4„ 3 EXIST. STEEL COLUMN EXIST. FLOOR DRAIN -- 2 1, 4„ EQ V-4" EQ 1'-4„ 01 ENLARGED DEMOLITION PLAN BAR AREA SCALE: 1/4"= V-0" 07 A•2 FURNITURE BY TENANT, TYP. c t22'-9" NEW COUNTERTOP @ 42" A.F.F. EQ V-4- EQ 1,-4" \/ V-6" 4 4 T-O„ OS — EXIST. FLOOR DRAIN EXIST. STEEL COLUMN M p8 A2 Opp 6 FD U EN TREAD & RISER _ . - a - — - - - - a4„PLYWOOD PLYWOOD DECK GLUED & SCREWED - WALL BEYOND ON 2X4 WOOD STUD o a ( 1 ( \ ( 1 ( \ ( ( ( (^ (^ (^ N v 14" A.F.F. WALL @ 16" O.C. o o T.O. PLATFORM SEE DETAIL 101A-2 4„ ' ( ) �, '- � � a NEW COUNTERTOP @ 42" A.F.F. Ev SLOPE 1:12' 2x4 WD STUD WALL @ 16" O.C. 14" A.F.F. 1' 4" EQ 1'-4" EQ 1'-4" W/ STUD SPACING @ 24" O.C. V T.O. LANDING a- 4am 1-01111 low f22'-y,, 0,0" ° a FIN N, FLOOR Q TOP OF PLYWOOD TO ALIGN PLYWOOD DECK 07 EXIST. CONC. SLAB ON 2X4 WOOD STUD 1 1/2" DIAMETER VERTICAL WI TOP OF FLOOR FINISH A 2 EXIST, CONC. SLAB i SUPPORT, TYP WALL O DE16lQ.C. 02 ENLARGED PROPOSED PLAN 2X WD BLOCKING @ ENDS & 16" O.C., MSC - EXIST. CONC. FOOTING WALL @ DETAIL 101A-2) BAR AREA SCALE: 114"= V-0" 12 AIR SECTION. ST AIR E 09 RAMPS CTION SCALE: 1/4" =1'-0" EXIST. WALL -1 1/2" DIAMETER 5'-0' t14'•0' ALUMINUM HANDRAIL MAX SLOPE 1: 12 091A-2 q EXISTING ACOUSTIC LAY -IN CEILING z 14" A.F.F. LANDING RAMP LENGTH T.O. LANDING 4'4' 1,-0,, EQ EQ EQ EQ 1'-0" - — 3000 PSI CONC. TO MATCH EXISTING THICKNESS BUT NOT LESS THAN 4". ° PLYWOOD DECK - — -- — WALL BEYOND —EXISTING MTL STUD PARTITION 5'-0 t14'-0" 1 6' 12„ ON 2X4 WOOD STUD o a LANDING WALL @ 16" O.C. c ' 21' 8„ 2„ (SEE DETAIL 10/A-2) N o o SLOPE 1,12 o NEW MTL STUD TRACK #3 MIN @ 8" O.C. N J,14" A.F.F. �-- '- (WIDTH TO MATCH EXIST.) • .e V T.O. LANDING 03 ENLARGED RAMP PLAN EXIST.CONC.SLAB THICKENED EDGE WI (2) #5 112" EXPANSION JOINT % \ NEW 2X WOOD HEADER SCALE:1/4" = V-0"CONC. SLAB CONCRETE SLAB W/ WWF (WIDTH TO MATCH EXIST.) SX8 THICKENED EDGE \!l 11/2"DIAMETERVERTICAL VAPOR BARRIER #3 MIN @ 16" O.C. STAGGERED x TRENCH WIDTH. REMOVE PORTION OF EXISTING WI (1) 45 REMOVE PORTION OF EXIST. WALL 11IA-2 DRILL & EPDXY 4" INTO EDGE OF EXISTING SLAB SLAB TO ACCOMODATE NEW RAMP SUPPORT, TYP. TO ACCOMODATE NEW OPENING. MID -DEPTH EXIST. CONC. FOOTING GRADED AND (REFINISH OPENING AS REQ'D) 23' A.F.F. OL TYP. SLAB ON GRADE PATCH COMPACTED EARTH v T.O. PLATFORM �' AT MECHANICAL/ELECTRICAL TRENCHES �/�BELOW CONC. SLAB 34" H. HANDRAIL, TYP. 09A ALTERNATE RAMP SECTION � NEW GRANITE COUNTERTOP @ 42" A.F.F. OVER 314" PLYWOOD BACKING 3'-0" 1'-0" 1 " 11" 11" 11" UP I;, (REINFORCE EXIST WALL AS REQ'D) SCALE:1/4' = V-0" 13 TYP. TRENCH DETAIL 4 EQ. ISERS SCALE: 3l4" =1'-0" '/a" PLYWOOD GLUED & SCREWED TO STUD LIVE LOAD =125 PSF NEW 2X WOOD SUPPORT T j WALL WI2%2" LONG WOOD SCREWS@ 12" O.C.(WIDTH TO MATCH EXIST.) 04 ENLARGED RAMP j` �P PT A N 2x4 WOOD STUD WALL @ 16" O.C. W/ STUD SPACING @ 24" O.C. WOOD VENEER jy jJ \CylVl jJ[�j (FASTEN STUDS TO TOP & BOTTOM PLATE W/ (2)12d NAILS EA SIDE, TYP.) ON EXIST, WALL NEW MTL STUD TRACK SCALE: 1/4" = V-0" (WIDTH TO MATCH EXIST.) E; " " EXISTING MTL STUD PARTITION 14" A.F.F. g " EXISTING BASE a T 0 PLATFORM w " " FINISHED FLOORING c 34" H. HANDRAIL, TYP. . " v a o 121A-2 8' LONG 2X4 WD BRACING @ EACH WALL Y4" X 3' LONG TAPCON EXISTING CONC. SLAB (NAIL TO EACH STUD & TOP & BOTTOM PLATES @ 48' O.C., MAX W/ 12d NAILS AS SHOWN) {2) EQ COT. C R 9LA8 RISE EXIST. N S 10 TYP. PLATFORM FRAMING DTL 06 WALL SECTION 05 ENLARGED DAMP PLAN SCALE: 3/4" = V-0" SCALE: 3/4" = V-0" SCALE: 114" = V-0" EQUIPMENT SCHEDULE ITEM# DESCRIPTION 1 BUILT IN CABINET 2 48" x IQ" ICE BIN 3 3 COMPARTMENT SINK 4 30 x 19" ICE BIN 5 HANO WASH SINK 6 REFRIGERATOR 7 KEG REFRIGERATOR 8 36 x 24" ICE BIN REV # DATE �i r� Z N L^u'LO N 0) Qco ® m Z LL W :D J z J Z V :D U) Q Z M F- , rN (`✓) O n_ ® Z 0 z F_ DRAWN BY SDC CHECKED BY SDC DATE 9-13-2013 SCALE AS NOTED JOB # 213005 SHEET# A d AIR ADMITTANCE VALVE, TYP. ROUTE NEW T VENT TO EXIST. 2" VENT FROM THE SINK THAT IS BEING REMOVED. FIELD VERIFY 1" FROM ICE BIN HAND EXACT LOCATION. SINK r� AAV BAR SINK NEW 1 Y4" IN WALL 1" FROM ICE BIN IN WALL ^ J HUB DRAIN 1" FROM ICE BIN FOR ICE AAV AAV NEW 2" IN WALL HUB DRAIN EXIST. FOR ICE " FIUB DRAIN 1"FROM ICE BIN �� FOR ICE AAV HUB DRAIN NEW 1 Y2" EXIST. 1 — FOR ICE IN WALL V 3" SAN EXIST. \ 3" F.D. NEW T SAN SANITARY ISOMETRIC DIAGRAM NOT TO SCALE HAND SINK i BAR SINK / yH&C Y2'H&C CONNECT TO EXIST. V H & C WATER LINES WATER ISOMETRIC DIAGRAM NOT TO SCALE K, PANELBOARD SCHEDULE 'B' (EXIST) 120/208 VO TS 3 PHASE 4 WIRE 400 AMP BUS 42 BRANCH POLES X FULL NEUTRAL. SURFACE MOUNTING 400 AMP MAIN C.B. SHORT CIRCUIT I= 22,000 AMP-SYM-RMS COND. & WIRE. AMPS LOAD - BKR C K T B U S C K TP BKR LOAD AMPS COND. & WIRE A B C P A A A B C 1/2' #12 14 WALK IN COOLER - EXIST 2 20 1 2 2 20 HOOD EF - EXIST 9 1/2, #12 14I 1 11 3 4 11 1 9 14 WALK IN COOLER - EXIST 2 20 5 6 2 20 HOOD EF -EXIST 9 14 1 11 7 8 11 1 9 17 WALK IN FREEZER - EXIST 2 20 9 10 2 20 HOOD SF - EXIST 8 17 1 1111 12 11 1 a 1/2' #10 26 DW WITH BOOSTER - EXIS 3 30 13 14 2 20 HOOD SF -EXIST 8 26 15 16 1 1 1 8 ?6 17 IS 2 20 GRILL EF - EXIST 6 1/2' #12 10 REF TABLE - EXIST 1 20 19 20 1 1 1 6 10 21 22 2 20 GRILL SF - EXIST 6 10 23 24.. _L 1 1 6 13 REFRIGERATOR - EXIST 25 26 1_ 20 REFRIGERATOR - ITEM #7 5 1/2' #12 112, #10 18 ICE MAKER - EXIST 2 30 27 2B SPACE 18 1 1 _L 29 30 20 ICE CREAM - EXIST 3 30 31 32 20 'I: 33 34 20 35 36 1 20 REFRIGERATOR - ITEM #7 5 1/2' #12 1/2, #12 51 REFRIGERATOR - ITEM #6 1 20 37 38 3 125 EXIST SUB -PANEL 'C' 49 1 1/4' #1 1 4 CASH REG - EXIST 1 1 39 40 47 SPACE 41 a2 39 )K TOTAL AMPS BUS A= 151 BUS H= 149 BUS C= 140 CONNECTED KVA= 3K THE NOTED DIRCUIT IS A NEW CIRCUIT TO THIS PANEL ALL OTHER CIRCUITS ARE SNG TO REMAIN: XE Xc )KW THE TDTAL BUS AMPS ARE BASED ON THE EXISTING AS -BUILT DRAWINGS PLUS THE4NErW LOAD AS SHOWN, ,. NOTE: THERE IS NO INCREASE IN SERVICE LOAD AS THE EQUIPMENT BEING REMOVED FROM THE BAR AREA EXCEEDS THE LOAD OF THE NEW EQUIPMENT. EXIST.120/208V, 3PH, EXIST. 800 AMP CONDUIT w J / E &FEEDER70REMAIN NOTE:PANEL'B'HASA3P, / FROM FPSERVIC r — — — — — — PANEL'C'THAT IS FEEDING r $ 1 w EXIST.125 ONDUIT I I & WI REMAIN [ EXIS � . EXIST 1 ST I M\ f IS7 L -/J i I 400A I I I 400A J i 225A I CAN I 800 3 I MCB I MCB -{ MCB I+— J 800 I PANEL I I PANEL II PANEL L _A. J L _B, _T . -C— J I 4 — — J — — L��— — EXIST. 400 AMP CONDUIT W— — i F_ I & WIRE TO REMAIN Rl�------- — — — — — - "> '' EXIST. WIREWAY TO REMAIN Oft'GiND =1— TO RE N AL CTRICAL RISER DIAGRAM NOT TO SCALE T I NEW 1Ys" IN WALL r - = AAV EXIST EXIST. 3" SAN ' 2" SAN N HUD DRAIN EXI 7 F.D. — � NEW 2" SAN I HU i PLUMBING PL AN CONNECT TO EXIST. 2" DRAIN FROM THE EXIST. SINK THAT IS BEING REMOVED NEW 2" IN WALL NEW 1Y" IN WAIL AAV _ AAV — — — — — — NtW H NEW BAR D HAND SINK SINK N 1Y2' IN WALL SCALE:1/4" = V-0" PLUMBING NOTES ELECTRICAL NOTES: LALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDANCE LELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL ALL NEW WITH APPLICABLE LOCAL CODES, RULES AND ORDINANCES. ELECTRICAL WORK INDICATERCONSTRUCTION SHALL BE IN ACCORDANCE WITH DRAWINGS AND APPLICABLE SPECIFICATll7NS,IF A PROBLEM IS 2.PLUMBING CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY ENCOUNTERED IN COMPLYING WITH THIS REQUIREMENT,CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. NOTIFY THE OWNER OR HIS REPRESENTATIVE AS SOON AS POSSIBLE AFTER DISCOVERY OF THE PROBLEM AND SHALL NOT PROCEED WITH THAT 3,ALL MATERIALS SHALL BE NEW. PORTION OF THE WORK UNTIL OWNER HAS DIRECTED CORRECTIVE ACTION. 4,REQUIRED INSURANCE SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR 2,ELECTRICAL CONTRACTOR SHALL VISIT JOB SITE AND FAMILIARIZE FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR HIMSELF WITH ALL CON➢ITIONS AFFECTING ELECTRICAL AND TELEPHONE THE ➢URATION OF THE WORK. INSTALLATION AND MAKE PROVISIONS AS TO THE COST THEREOF, 5,PLUMBING CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, 3,ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE NATIONAL INSPECTIONS AND TESTS, PLUMBING CONTRACTOR TO OBTAIN PERMIT AND ELECTRIC CODE AND THE FLORIDA BUILDING CODE. APPROVED SUBMITTALS PRIOR TO BEGINNING WORK OR ORDERING EQUIPMENT. PLUMBING CONTRACTOR MUST BE PRESENT FOR ALL 4.DO NOT !SCALE THE ELECTRICAL DRAWINGS,REFER TO ARCHITECTURAL INSPECTIONS OF HIS WORK BY REGULATORY AUTHORITIES. PLANS AND ELEVATIONS FOR EXACT LOCATION OF ALL EQUIPMENT. CONFIRM WITH OWNERS REPRESENTATIVE. 6,DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF FIXTURES, PIPING AND EQUIPMENT. 5.MINIMUM WIRE SIZE SHALL BE #12 A,W,G EXCLUDING CONTROL WIRING. UNLESS OTHERWISE NOTED, ALL CONDUCTORS SHALL BE COPPER WITH THHN 7,ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INSULATION. INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION, REPORT ANY DISCREPANCY TO ENGINEER/ARCHITECT PRIOR TO BEGINNING 6,DUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST CONSTRUCTION. ALLOY WITH THREADED HUBS IN WET OR DAMP LOCATIONS AND SPECIAL ENCLOSURES FOR OTHER CLASSIFIED AREAS. &VERIFY LOCATION, SIZE, DIRECTION OF FLOW AND INVERTS OF ALL EXISTING UTILITIES PRIOR TO BEGINNING OF CONSTRUCTION. ADVISE 7,CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE ENGINEER OF ANY ➢ISCREPANCIES. FROM DEFECTS FROM A PERIOD OF NOT LESS THAN ONE YEAR FROM DATE OF ACCEPTANCE. 9,ABOVE GRADE DOMESTIC WATER PIPE SHALL BE TYPE 'L' HARD DRAWN COPPER WITH CAST BRASS OR WROUGHT COPPER FITTINGS & NO LEAD SOLDER. BELOW &.CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL GRADE DOMESTIC WATER PIPE SHALL BE TYPE 'K' COPPER, PIPES PASSING CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE THRU THE SLAB, BEAMS, OR BLOCK WALLS SHALL BE PROTECTED FROM OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THERE BY. CORROSION PER FPC-305.1. PIPES PASSING THRU FOUNDATION WALLS SHALL BE PROTECTED PER FPC-305,5, 9.ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE lOSOIL, WASTE, & VENT PIPING. SHALL BE CAST IRON OR SOLID WALL SCH 40 PVC IF CODE PERMITS. 1O,CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS AND 1LBELOW GRADE GAS PIPING SHALL BE POLYETHYLENE PLASTIC PIPE INSTALLE➢ PER TESTING. CONTRACTOR TO OBTAIN PERMIT ANR APPROVED SUBMITTALS FBC-FUEL GAS SECTIONS 403 & 404, ABOVE GRADE EXPOSED GAS PIPING SHALL BE PRIOR TO BEGINNING WORK OR ORDERING EQUIPMENT, SCH 40 GALVANIZED PIPE. ABOVE GRADE CONCEALED PIPING SHALL BE SCH 40 GALVANIZED PIPE. ILTHE ELECTRICAL INSTALLATION SHALL MEET ALL REQUIREMENTS OF POWER AND TELEPHONE COMPANIES. 12.DIELECTRIC COUPLINGS ARE REQUIRED BETWEEN ALL DISSIMILAR METAL IN PIPING AND EQUIPMENT CONNECTIONS. 12.CONTRAGTOR SHALL COORDINATEWITH MECHANICAL DRAWINGS AND PROVIDE ALL NECESSARY CONTROL WIRING, 131SOLATE COPPER PIPE FROM HANGER OR SUPPORTS WITH ISOLATOR PAD, 14.PLUMBING CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND 13,ALL CIRCUIT BREAKERS FEEDING MECHANICAL EQUIPMENT SHALL BE WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN ONE HACR TYPE CIRCUIT BREAKERS OR FUSED SWITCHES AS INDICATED. (1) YEAR FROM DATE OF ACCEPTANCE BY OWNER. CORRECTION OF ANY ECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL 14.PROVIDE AND INSTALL CONDUIT, CONDUCTORS, PULL WIRES, BOXES, CLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE COVER PLATES, DEVICES FOR ALL OUTLETS AS INDICATED. INSTALLATION WHICH MAY HAVE BEEN DAMAGED, .000 15,CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING 13,ALL CONDENSATE DRAIN PIPING SHALL BE SCH 40 PVC. REQUIRED IOF HIS WORK. 16,TEST DOMESTIC WATER TO HYDROSTATIC PRESSURE OF 100 PSI AND 16,ELECTRICAL CONTRACTOR SHALL LABEL EXTERIOR OF ALL PANELS AND REMAIN LEAK FREE FOR 24 HOURS.PROVIDE ALL NECESSARY TEST PROVIDE COMPLETE TYPEWRITTEN DIRECTORIES. EQUIPMENT, PERFORM TEST IN PRESENCE OF OWNER'S REPRESENTATIVE, ENTER TEST RESULTS IN GENERAL CONTRACTOR JOB LOG,STERILIZE WATER 17.ALL ELECTRICAL AND TELEPHONE/DATA OUTLETS TO BE 113' AFF PIPING WITH SOLUTION CONTAINING NOT LESS THAN 50 PARTS PER UNLESS NOTED OTHERWISE, VERTICALLY MOUNTED. MILLION OF CHLORINE AND ALLOW TO REMAIN IN SYSTEM FOR A PERIOD OF EIGHT (24)HOURS. FLUSH SYSTEM AFTER STERILIZATION, ALL COST FOR 1&,ALL LIGHT SWITCHES TO BE AT 48' AFF, STERILIZATION AND EQUIPMENT SHALL BE PROVIDED BY THE CONTRACTOR. 19,LAY IN LIGHT FIXTURES TO BE SUPPORTED AT ALL FOUR CORNERS AND 17ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE STOPS TO STRUCTURE ABOVE. AND APPROPRIATELY MARKED ACCESS PANELS. COORDINATE LOCATIONS WITH AND GENERAL CONTRACTOR PRIOR TO INSTALLATION. 20.ALL ELECTRICAL WIRING SHALL BE THE RESPONSIBILITY OF THE 18, THE DESIGN & INSTALLATION OF THE PLUMBING SYSTEM & ALL APPURTEN- ELECTRICAL CONTRACTOR, ALL ELECTRICAL WIRING FOR HVAC SYSTEM ANCES SHALL COMPLY STRICTLY WITH THE APPLICABLE PROVISIONS OF THE INCLUDING' CONTROLS, THERMOSTATS, POWER, ETC. SHALL BE THE FLORIDA BUILDING PLUMBING CODE & THE LOCAL AMENDMENTS TO THE FLORIDA RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. BUILDING PLUMBING CODE. 21,PANELBOARDS, ALL CURRENT CARRYING BUSES SHALL BE COPPER, ALL GROUND BUS BARS SHALL BE COPPER PANELBOARD ENCLOSURES SHALL BE FURNISHED WITHOUT PRE -PUNCHED CONCENTRIC HOLES.AIC RATINGS SHALL BE AS INDICATED ON PANELBOARD SCHEDULES', 22,DISCONNECT SWITCHES SHALL BE H,P, RATED,HEAVY DUTY, ENCLOSURES AS REQUIRE➢ BY EXPOSURE. 23.ALL EXPOSED EXTERIOR CONDUITS SHALL BE RIGID METAL. ALL UNDERGROUND CONDUIT SHALL BE SCH 40 PVC. INTERIOR LIGHTING AND RECEPTACLE CONDUIT SHALL BE ,EMT, ELECTRICAL PLAN NOTES 1. THE NOTED CIRCUIT IS AN EXISTING 1P, 20A DEDICATED CIRCUIT THAT IS BEING ABANDONED AS PART OF THIS PROJECT. THIS CIRCUIT WILL BE RE -USED TO FEED THE NEW REFRIGERATOR. THE EXISTING OUTLET LOCATION WILL NEED TO BE RELOACTED TO THE NEW LOCATION SHOWN. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID & INCLUDE ALL ASSOCIATED COSTS TO PROVIDE THE NOTED CIRCUITING FOR THE NEW EQUIPMENT SHOWN. 2. IF THERE ARE ANY RECEPTACLES THAT ARE EXISTING & ARE NOT TO BE RE -USED OR RELOCATED, THEY SHALL BE PROVIDED WITH A BLANK COVER PLATE IF THE WALL IS TO REMAIN. IF THE WALL IS BEING REMOVED, THE RECEPTACLE SHALL BE REMOVED & THE CONDUIT & WIRING TERMINATED ABOVE AN ACCESSIBLE CEILING. CONNECT TO EXISTING BAR AREA OUTLET CIRCUIT THIS IS BEING ABANDONED IN DEMO WORK. 0 u1 EXIST. CKT EXIST. CKT GFI B-36, NOTE 1 B-26, NOTE 1 080 ;FLOC GFI GFI f-di�1■� EXIST. CKT B-37. NOTE 1 LEGEND: EXIST EXISTING OUTLET TO REMAIN. PROVIDE OR EXTEND EXISTING CIRCUITING AS SHOWN. I RELOC EXISTING OUTLET TO BE RELOCATED TO THE LOCATION SHOWN. PROVIDE OR EXTEND EXISTING CIRCUITING AS SHOWN. I NEW NEW OUTLET TO BE PROVIDED IN LOCATION SHOWN. RELOC PROVIDE OR EXTEND EXISTING CIRCUITING AS SHOWN. GFI — — — — NEW EXIST.— — — _LIV — CONNECT TO EXISTING BAR AREA OUTLET CIRCUIT THIS IS BEING ABANDONED IN DEMO WORK. ,RICAL PLAN SCALE: 1(4" = V-0" j JONES & CONDE, LLC ^ 4440 PGA BOULEVARD J`7p PALM BEACH GARDENS, FL 33410 CERTIFICATE OF AUTHORIZATION #29783 DAVID R JONES, PE #41042 TEL (561)309-9017 EMAIL: david-jones-conde®bellsouth.net REV # DATE a a �I 1 ..,, �� 11 fy- f 13 O 4, LL e ZI W ENO a m M Lu LL o ica 2 L1J o c r 07 J a H- Z LLJ�3 0 ;I i {i{ 49�s' rF�a CO A O — r- Ln co 0) Ln U3 "t M o O UQ aLLry cy) L L)@ E W [n CL c L � Q L _� 5 d N cz C -Cl— CID M DRAWN BY SDC CHECKED BV DRJ DATE 9-13-2013 SCALE AS NOTED JOB # 213005 SHEET# M -