Loading...
HomeMy WebLinkAboutEnergy CodeFORM 60OA-2004R EnergyGauge@ 4.5.2 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: Lot 150 Venture Out Saint Lucie County-2008-08-BI&OM Address: Permittin City, State: , FL Permit N b Owner: Jurisdiction Number: Climate Zone: Central 1. New construction or existing New _ 2. Single family or multi -family Single family 3. Number of units, if multi -family 1 _ 4. Number of Bedrooms 2 _ 5. Is this a worst case? No _ 6. Conditioned floor area (ft2) 851 ft2 7. _ Glass type and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a(Sngle Default) 102.0 ftz b. SHGC: (or Clear or Tint DEFAULT) 7b. (Clear) 102.0 ft2 _ 8. Floor types a. Raised Wood, Stem Wall R=22.0, 851.02 b. N/A c. N/A 9. Wall types a. Concrete, Light Weight - hit Insul, Exterior R=25.0, 115.7 ftz b. Concrete, Light Weight.- Int Insul, Exterior R=25.0, 298.2 ft2 _ c. Concrete, Light Weight - Int Insul, Exterior R=25.0, 53.0 ft2 d. Concrete, Light Weight - hit Insul, Exterior R=25.0, 97.1 ft2 _ e. Concrete, Light Weight - hit Insul, Exterior R=25.0, 267.8 ft2 _ 10. Ceiling types (white roof) a. Under Attic R=30.0, 851.0 112 b. N/A c. N/A _ 11. Ducts(white roof) a. Sup: Unc. Ret: Unc. AH: Interior Sup. R=6.0, 232.0 ft b. N/A 12. Cooling systems a. Central Unit/Split b. N/A c. N/A 13. Heating systems a. Electric Heat Pump/Split b. N/A c. N/A 14. Hot water systems a. N/A b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.12 Total as -built points: 10406 PASS Total base points: 12169 I hereby certify thatthe plans and specifications covered by this calculation are in compliance with the Florida Energy Code. % PREPARED BY: DATE: I hereby certify that this buildin as desi ed, is in compliance with the Florida E Code OWNER/AGE DATE: I(! n0 1 Predominant alass tvne. Fhr adtual alas, tvne and nraa, ,aa Summer Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: & Winter Glass output on pages 2&4. EnergyGauge® (Version: FLRCPB v4.5.2) Cap: 24.0 kBtu/hr _ SEER:14.00 _ Cap: 24.0 kBtu/hr HSPF: 8.50 CF, _ 17, FORM 60OA-2004R EnergyGauge@ 4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 851.0 24.35 3730.0 1.Single, Clear SE 1.0 6.4 34.6 61.07 0.97 2054.0 2.Single, Clear NE 0.1 6.4 34.6 47.10 1.00 1626.0 3.Single, Clear NW 1.0 4.0 5.4 40.72 0.92 203.0 4.Single, Clear W 1.0 6.4 17.3 57.68 0.98 972.0 5.Single, Clear SW 1.0 4.2 10.2 56.99 0.90 527.0 As -Built Total: 102.0 5382.0 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 0.0 0.00 0.0 1. Concrete, Lt Wt Int Insul, Exterior 25.0 115.7 0.01 1.7 Exterior 831.8 1.90 1580.3 2. Concrete, Lt Wt Int Insul, Exterior 25.0 298.2 0.01 4.3 3. Concrete, Lt Wt Int Insul, Exterior 25.0 53.0 0.01 0.8 4. Concrete, Lt Wt Int Insul, Exterior 25.0 97.1 0.01 1.4 5. Concrete, Lt Wt Int Insul, Exterior 25.0 267.8 0.01 3.8 Base Total: 831.8 1680.3 As -Built Total: 831.8 11.9 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 1.Exterior Insulated 21.8 4.80 104.4 Exterior 35.4 4.80 169.9 2.Exterior Insulated 13.6 4.80 65.5 Base Total: 36.4 169.9 As -Built Total: 35.4 169.9 CEILING TYPES Area X BSPM = Points Type (White Root) R-Value Area X SPM X SCM = Points Under Attic 851.0 2.13 1812.6 1. Under Attic 30.0 851.0 2.13 X 0.55 996.9 Base Total: 851.0 1812.6 As -Built Total: 851.0 996.9 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 0.0(p) 0.0 0.0 1. Raised Wood, Stem Wall 22.0 851.0 -1.80 -1531.8 Raised 851.0 -3.43 -2918.9 Base Total: -2918.9 As -Built Total: 851.0 -1631.8 INFILTRATION Area X BSPM = Points Area X SPM = Points 851.0 14.31 12177.8 851.0 14.31 12177.8 EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCPB v4.5.2 t FORM 60OA-2004R EnergyGauge@ 4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , FL, PERMIT #: r BASE AS -BUILT Summer Base Points: 16551.8 Summer As -Built Points: 17206.8 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Central Unit 24000btuh ,SEER/EFF(14.0) Ducts:AU(S),Att(R),Int(AH),R6.0(INS) 17207 1.00 (1.05 x 1.150 x 0.90) 0.244 0.950 4314.6 16551.8 0.3250 6379.3 17206.8 1.00 1.084 0.244 0.950 4314.6 EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004R FLRCPB v4.5.2 FORM 60OA-2004R EnergyGauge@ 4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:,, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point .18 851.0 9.11 1395.0 1.Single, Clear SE 1.0 6.4 34.6 10.59 1.02 372.0 2.Single, Clear NE 0.1 6.4 34.6 14.70 1.00 508.0 3.Single, Clear NW 1.0 4.0 5.4 14.97 1.00 80.0 4.Single, Clear W 1.0 6.4 17.3 13.25 1.00 229.0 5.Single, Clear SW 1.0 4.2 10.2 11.59 1.03 122.0 As -Built Total: 102.0 1311.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 0.0 0.00 0.0 1. Concrete, Lt Wt Int Insul, Exterior 25.0 115.7 0.54 62.8 Exterior 831.8 2.00 1663.5 2. Concrete, Lt Wt Int Insul, Exterior 25.0 298.2 0.54 161.9 3. Concrete, Lt Wt Int Insul, Exterior 25.0 53.0 0.54 28.7 4. Concrete, Lt Wt Int Insul, Exterior 25.0 97.1 0.54 52.7 5. Concrete, Lt Wt Int Insul, Exterior 25.0 267.8 0.54 145.4 Base Total: 831.8 1663.5 As -Built Total: 831.8 451.5 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 1.Exterior Insulated 21.8 5.10 111.0 Exterior 35.4 5.10 180.5 2.Exterior Insulated 13.6 5.10 69.6 Base Total: 36.4 180.5 As -Built Total: 36.4 180.5 CEILING TYPES Area X BWPM = Points Type (White Root) R-Value Area X WPM X WCM = Points Under Attic 851.0 0.64 544.6 1. Under Attic 30.0 851.0 0.64 X 1.04 568.6 Base Total: 851.0 544.6 As -Built Total: 851.0 568.6 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 0.0(p) 0.0 0.0 1. Raised Wood, Stem Wall 22.0 851.0 0.30 255.3 Raised 851.0 -0.20 -170.2 Base Total: .170.2 As -Built Total: 851.0 265.3 INFILTRATION Area X BWPM = Points Area X WPM = Points 851.0 -0.28 -238.3 851.0 -0.28 -238.3 EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCPB v4.5.2 FORM 60OA-2004R EnergyGaugeO 4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , FL, PERMIT #: BASE AS -BUILT Winter Base Points: 3375.2 Winter As -Built Points: 2528.7 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 24000 btuh ,EFF(8.5) Ducts:Att(S),Att(R),lnt(AH),R6.0 2528.7 1.000 (1.081 x 1.160 x 0.92) 0.402 1.000 1171.3 3375.2 0.5640 1869.9 2528.7 1.00 1.164 0.402 1.000 1171.3 EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCPS v4.5.2 FORM 60OA-2004R EnergyGaugeO 4.5.2 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: , , FL, PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 2 2460.00 4920.0 2 1.00 2460.00 1.00 4920.0 As -Built Total: 4920.0 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points 5379 1870 4920 12169 1 4315 1171 4920 10406 PASS EnergyGauge'rm DCA Form 60OA-2004R EnergyGauge@1FlaRES'2004R FLRCPB v4.5.2 FORM 60OA-2004R EnergyGauge@ 4.5.2 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , , FL, , PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCPB v4.5.2 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 88.8 The higher the score, the more efficient the home. ,,, FL, 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Single family _ a. Central Unit/Split Cap: 24.0 kBtu/hr 3. Number of units, if multi -family 1 _ SEER: 14.00 _ 4. Number of Bedrooms 2 _ b. N/A _ 5. Is this a worst case? No 6. Conditioned floor area (ft2) 851 ftz _ c. N/A 7. Glass type and area: (Label reqd. by 13-104.4.5 if not default) _ a. U-factor: Description Area 13. Heating systems _ (or Single or Double DEFAULT) 7a(Sngle Default) 102.0 ftz _ a. Electric Heat Pump/Split Cap: 24.0 kBtu/hr b. SHGC: HSPF: 8.50 _ (or Clear or Tint DEFAULT) 7b. (Clear) 102.0 ft2 _ b. N/A 8. Floor types a. Raised Wood, Stem Wall R=22.0, 851.0ft2 _ c. N/A _ b. N/A _ c. N/A _ 14. Hot water systems 9. Wall types a. N/A • a. Concrete, Light Weight - Int Insul, Exterior R=25.0, 115.7 ft2 _ b. Concrete, Light Weight - Int Insul, Exterior R=25.0, 298.2 ft2 _ b. N/A c. Concrete, Light Weight - Int Insul, Exterior R=25.0, 53.0 ft2 _ • d. Concrete, Light Weight - Int Insul, Exterior R=25.0, 97.1 ft2 _ c. Conservation credits _ e. Concrete, Light Weight - Int Insul, Exterior R=25.0, 267.8 ft2 _ (HR-Heat recovery, Solar 10. Ceiling types (white roof) DHP-Dedicated heat pump) a. Under Attic R=30.0, 851.0 ft2 _ 15. HVAC credits CF, b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A _ HF-Whole house fan, 11. Ducts(white roof) PT -Programmable Thermostat, a. Sup: Unc. Ret: Unc. AH: Interior Sup. R=6.0, 232.0 ft _ MZ-C-Multizone cooling, b. N/A _ MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded in this home before final ins ction. O rwi e, a new EPL Display Card wi be co pleted based on installed Code c mpl ant a es Builder Signature: Date: Address of New Home: l O 7.1 f' C�C4-J ®4`4 City/FL Zip:r�COD Z-or - U a a1�1 I VU 1 *NOTE. The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStarTmdesignation), your home may qualify for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for information and a list of certified Raters. For information about Florida's Energy Efciency Code For Building Construction, contact the Department of CommunityAffairs at 8501487-1824. 1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on ages 2&4. EnergyGauge® (Version: FLPRCP> v4.5.2)