HomeMy WebLinkAboutEnergy CodeFORM 60OA-2004R EnergyGauge@ 4.5.2
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: Lot 150 Venture Out Saint Lucie County-2008-08-BI&OM
Address: Permittin
City, State: , FL Permit N b
Owner: Jurisdiction Number:
Climate Zone: Central
1.
New construction or existing
New _
2.
Single family or multi -family
Single family
3.
Number of units, if multi -family
1 _
4.
Number of Bedrooms
2 _
5.
Is this a worst case?
No _
6.
Conditioned floor area (ft2)
851 ft2
7.
_
Glass type and area: (Label reqd. by 13-104.4.5 if not default)
a. U-factor: Description Area
(or Single or Double DEFAULT) 7a(Sngle
Default) 102.0 ftz
b. SHGC:
(or Clear or Tint DEFAULT) 7b.
(Clear) 102.0 ft2 _
8.
Floor types
a. Raised Wood, Stem Wall
R=22.0, 851.02
b. N/A
c. N/A
9.
Wall types
a. Concrete, Light Weight - hit Insul, Exterior
R=25.0, 115.7 ftz
b. Concrete, Light Weight.- Int Insul, Exterior
R=25.0, 298.2 ft2 _
c. Concrete, Light Weight - Int Insul, Exterior
R=25.0, 53.0 ft2
d. Concrete, Light Weight - hit Insul, Exterior
R=25.0, 97.1 ft2 _
e. Concrete, Light Weight - hit Insul, Exterior
R=25.0, 267.8 ft2 _
10. Ceiling types (white roof)
a. Under Attic
R=30.0, 851.0 112
b. N/A
c. N/A
_
11.
Ducts(white roof)
a. Sup: Unc. Ret: Unc. AH: Interior
Sup. R=6.0, 232.0 ft
b. N/A
12. Cooling systems
a. Central Unit/Split
b. N/A
c. N/A
13. Heating systems
a. Electric Heat Pump/Split
b. N/A
c. N/A
14. Hot water systems
a. N/A
b. N/A
c. Conservation credits
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HVAC credits
(CF-Ceiling fan, CV -Cross ventilation,
HF-Whole house fan,
PT -Programmable Thermostat,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.12 Total as -built points: 10406 PASS
Total base points: 12169
I hereby certify thatthe plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code. %
PREPARED BY:
DATE:
I hereby certify that this buildin as desi ed, is in compliance
with the Florida E Code
OWNER/AGE
DATE: I(! n0
1 Predominant alass tvne. Fhr adtual alas, tvne and nraa, ,aa Summer
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
& Winter Glass output on pages 2&4.
EnergyGauge® (Version: FLRCPB v4.5.2)
Cap: 24.0 kBtu/hr _
SEER:14.00 _
Cap: 24.0 kBtu/hr
HSPF: 8.50
CF, _
17,
FORM 60OA-2004R EnergyGauge@ 4.5.2
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , FL, PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned
X BSPM
=
Points
Overhang
Floor Area
Type/SC Ornt
Len Hgt
Area X SPM X SOF
= Points
.18 851.0
24.35
3730.0
1.Single, Clear SE
1.0 6.4
34.6
61.07 0.97
2054.0
2.Single, Clear NE
0.1 6.4
34.6
47.10 1.00
1626.0
3.Single, Clear NW
1.0 4.0
5.4
40.72 0.92
203.0
4.Single, Clear W
1.0 6.4
17.3
57.68 0.98
972.0
5.Single, Clear SW
1.0 4.2
10.2
56.99 0.90
527.0
As -Built Total:
102.0
5382.0
WALL TYPES
Area X
BSPM
= Points
Type
R-Value
Area
X SPM =
Points
Adjacent
0.0
0.00
0.0
1. Concrete, Lt Wt Int Insul, Exterior
25.0
115.7
0.01
1.7
Exterior
831.8
1.90
1580.3
2. Concrete, Lt Wt Int Insul, Exterior
25.0
298.2
0.01
4.3
3. Concrete, Lt Wt Int Insul, Exterior
25.0
53.0
0.01
0.8
4. Concrete, Lt Wt Int Insul, Exterior
25.0
97.1
0.01
1.4
5. Concrete, Lt Wt Int Insul, Exterior
25.0
267.8
0.01
3.8
Base Total:
831.8
1680.3
As -Built Total:
831.8
11.9
DOOR TYPES
Area X
BSPM
= Points
Type
Area
X SPM =
Points
Adjacent
0.0
0.00
0.0
1.Exterior Insulated
21.8
4.80
104.4
Exterior
35.4
4.80
169.9
2.Exterior Insulated
13.6
4.80
65.5
Base Total:
36.4
169.9
As -Built Total:
35.4
169.9
CEILING TYPES
Area X
BSPM
= Points
Type (White Root) R-Value Area X SPM X SCM =
Points
Under Attic
851.0
2.13
1812.6
1. Under Attic
30.0
851.0 2.13 X 0.55
996.9
Base Total:
851.0
1812.6
As -Built Total:
851.0
996.9
FLOOR TYPES
Area X
BSPM
= Points
Type
R-Value
Area
X SPM =
Points
Slab
0.0(p)
0.0
0.0
1. Raised Wood, Stem Wall
22.0
851.0
-1.80
-1531.8
Raised
851.0
-3.43
-2918.9
Base Total:
-2918.9
As -Built Total:
851.0
-1631.8
INFILTRATION
Area X
BSPM
= Points
Area X SPM =
Points
851.0
14.31
12177.8
851.0
14.31
12177.8
EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCPB v4.5.2
t
FORM 60OA-2004R EnergyGauge@ 4.5.2
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , FL, PERMIT #:
r
BASE
AS -BUILT
Summer Base Points:
16551.8
Summer As -Built Points:
17206.8
Total Summer X System
= Cooling
Total X Cap
X Duct X System X
Credit
= Cooling
Points Multiplier
Points
Component Ratio
Multiplier Multiplier
Multiplier
Points
(System - Points)
(DM x DSM x AHU)
(sys 1: Central Unit 24000btuh ,SEER/EFF(14.0) Ducts:AU(S),Att(R),Int(AH),R6.0(INS)
17207 1.00
(1.05 x 1.150 x 0.90) 0.244
0.950
4314.6
16551.8 0.3250
6379.3
17206.8 1.00
1.084 0.244
0.950
4314.6
EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004R FLRCPB v4.5.2
FORM 60OA-2004R
EnergyGauge@ 4.5.2
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS:,, FL,
PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BWPM =
Points
Overhang
Floor Area
Type/SC Ornt
Len Hgt
Area X WPM X WOF = Point
.18 851.0
9.11
1395.0
1.Single, Clear SE
1.0 6.4
34.6
10.59 1.02
372.0
2.Single, Clear NE
0.1 6.4
34.6
14.70 1.00
508.0
3.Single, Clear NW
1.0 4.0
5.4
14.97 1.00
80.0
4.Single, Clear W
1.0 6.4
17.3
13.25 1.00
229.0
5.Single, Clear SW
1.0 4.2
10.2
11.59 1.03
122.0
As -Built Total:
102.0
1311.0
WALL TYPES
Area X
BWPM
= Points
Type
R-Value
Area X
WPM =
Points
Adjacent
0.0
0.00
0.0
1. Concrete, Lt Wt Int Insul, Exterior
25.0
115.7
0.54
62.8
Exterior
831.8
2.00
1663.5
2. Concrete, Lt Wt Int Insul, Exterior
25.0
298.2
0.54
161.9
3. Concrete, Lt Wt Int Insul, Exterior
25.0
53.0
0.54
28.7
4. Concrete, Lt Wt Int Insul, Exterior
25.0
97.1
0.54
52.7
5. Concrete, Lt Wt Int Insul, Exterior
25.0
267.8
0.54
145.4
Base Total:
831.8
1663.5
As -Built Total:
831.8
451.5
DOOR TYPES
Area X
BWPM
= Points
Type
Area X
WPM =
Points
Adjacent
0.0
0.00
0.0
1.Exterior Insulated
21.8
5.10
111.0
Exterior
35.4
5.10
180.5
2.Exterior Insulated
13.6
5.10
69.6
Base Total:
36.4
180.5
As -Built Total:
36.4
180.5
CEILING TYPES Area X
BWPM
= Points
Type (White Root) R-Value Area X WPM X WCM =
Points
Under Attic
851.0
0.64
544.6
1. Under Attic
30.0
851.0 0.64 X 1.04
568.6
Base Total:
851.0
544.6
As -Built Total:
851.0
568.6
FLOOR TYPES
Area X
BWPM
= Points
Type
R-Value
Area X
WPM =
Points
Slab
0.0(p)
0.0
0.0
1. Raised Wood, Stem Wall
22.0
851.0
0.30
255.3
Raised
851.0
-0.20
-170.2
Base Total:
.170.2
As -Built Total:
851.0
265.3
INFILTRATION
Area X
BWPM
= Points
Area X
WPM =
Points
851.0
-0.28
-238.3
851.0
-0.28
-238.3
EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCPB v4.5.2
FORM 60OA-2004R EnergyGaugeO 4.5.2
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , FL, PERMIT #:
BASE
AS -BUILT
Winter Base Points:
3375.2
Winter As -Built Points:
2528.7
Total Winter X System =
Heating
Total X Cap
X Duct X System X
Credit
= Heating
Points Multiplier
Points
Component Ratio
Multiplier Multiplier
Multiplier
Points
(System - Points)
(DM x DSM x AHU)
(sys 1: Electric Heat Pump 24000 btuh ,EFF(8.5) Ducts:Att(S),Att(R),lnt(AH),R6.0
2528.7 1.000
(1.081 x 1.160 x 0.92) 0.402
1.000
1171.3
3375.2 0.5640
1869.9
2528.7 1.00
1.164 0.402
1.000
1171.3
EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCPS v4.5.2
FORM 60OA-2004R EnergyGaugeO 4.5.2
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS: , , FL, PERMIT #:
BASE
AS -BUILT
WATER HEATING
Number of X Multiplier = Total
Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms
Volume Bedrooms Ratio Multiplier
2 2460.00 4920.0
2 1.00 2460.00 1.00 4920.0
As -Built Total: 4920.0
CODE
COMPLIANCE
STATUS
BASE
AS -BUILT
Cooling + Heating +
Points Points
Hot Water
Points
= Total
Points
Cooling
Points
+ Heating + Hot Water = Total
Points Points Points
5379 1870
4920
12169
1 4315
1171 4920 10406
PASS
EnergyGauge'rm DCA Form 60OA-2004R EnergyGauge@1FlaRES'2004R FLRCPB v4.5.2
FORM 60OA-2004R
EnergyGauge@ 4.5.2
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: , , FL, , PERMIT #:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
606.1.ABC.1.1
Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area.
Exterior & Adjacent Walls
606.1.ABC.1.2.1
Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from and is sealed to the foundation to the top plate.
Floors
606.1.ABC.1.2.2
Penetrations/openings >1/8" sealed unless backed by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter, penetrations and seams.
Ceilings
606.1.ABC.1.2.3
Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures
606.1.ABC.1.2.4
Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Multi -story Houses
606.1.ABC.1.2.5
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
606.1.ABC.1.3
Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
612.1
Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir
breaker electric or cutoff as must be provided. External or built-in heat trap required.
Swimming Pools & Spas
612.1
Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficiency of 78%.
Shower heads
612.1
Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems
610.1
All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
607.1
Separate readily accessible manual or automatic thermostat for each system.
Insulation
604.1, 602.1
Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCPB v4.5.2
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 88.8
The higher the score, the more efficient the home.
,,, FL,
1.
New construction or existing
New _
12. Cooling systems
2.
Single family or multi -family
Single family _
a. Central Unit/Split
Cap: 24.0 kBtu/hr
3.
Number of units, if multi -family
1 _
SEER: 14.00 _
4.
Number of Bedrooms
2 _
b. N/A
_
5.
Is this a worst case?
No
6.
Conditioned floor area (ft2)
851 ftz _
c. N/A
7.
Glass type and area: (Label reqd. by 13-104.4.5 if not default)
_
a. U-factor: Description Area
13. Heating systems
_
(or Single or Double DEFAULT) 7a(Sngle
Default) 102.0 ftz _
a. Electric Heat Pump/Split
Cap: 24.0 kBtu/hr
b. SHGC:
HSPF: 8.50 _
(or Clear or Tint DEFAULT) 7b.
(Clear) 102.0 ft2 _
b. N/A
8.
Floor types
a. Raised Wood, Stem Wall
R=22.0, 851.0ft2 _
c. N/A
_
b. N/A
_
c. N/A
_
14. Hot water systems
9.
Wall types
a. N/A
•
a. Concrete, Light Weight - Int Insul, Exterior
R=25.0, 115.7 ft2
_
b. Concrete, Light Weight - Int Insul, Exterior
R=25.0, 298.2 ft2 _
b. N/A
c. Concrete, Light Weight - Int Insul, Exterior
R=25.0, 53.0 ft2
_
•
d. Concrete, Light Weight - Int Insul, Exterior
R=25.0, 97.1 ft2 _
c. Conservation credits
_
e. Concrete, Light Weight - Int Insul, Exterior
R=25.0, 267.8 ft2 _
(HR-Heat recovery, Solar
10. Ceiling types (white roof)
DHP-Dedicated heat pump)
a. Under Attic
R=30.0, 851.0 ft2 _
15. HVAC credits
CF,
b. N/A
_
(CF-Ceiling fan, CV -Cross ventilation,
c. N/A
_
HF-Whole house fan,
11.
Ducts(white roof)
PT -Programmable Thermostat,
a. Sup: Unc. Ret: Unc. AH: Interior
Sup. R=6.0, 232.0 ft _
MZ-C-Multizone cooling,
b. N/A
_
MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed (or exceeded
in this home before final ins ction. O rwi e, a new EPL Display Card wi be co pleted
based on installed Code c mpl ant a es
Builder Signature: Date:
Address of New Home: l O 7.1 f' C�C4-J ®4`4 City/FL Zip:r�COD
Z-or - U a a1�1 I VU 1
*NOTE. The home's estimated energy performance score is only available through the FLARES computer program.
This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStarTmdesignation),
your home may qualify for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for
information and a list of certified Raters. For information about Florida's Energy Efciency Code For Building
Construction, contact the Department of CommunityAffairs at 8501487-1824.
1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on ages 2&4.
EnergyGauge® (Version: FLPRCP> v4.5.2)