HomeMy WebLinkAboutNOA; 5-V Crimp Metal Roofing Panel SystemMIAMFI]ADE
BUILDING CODE COMPLIANCE OFFICE (BCCO)
PRODUCT CONTROL DMSION
NOTICE OF ACCEPTANCE (NOA)
Southeastern Metals Manufacturing Co., Inc.
11801 Industry Drive
Jacksonville, FL: 32218
MIAMI-DADE COUNTY, FLORIDA
METRO-DADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130-1563
(305) 375-2901 FAX (305) 375-2908
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted
by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by
the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right
to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane of the,Florida Building Code.
DESCRIPTION: 5 V "Crimp metal Roofingxanel.SysteIn
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively. affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This revises NOA # 06-1012.08 and consists of pages 1 through 5.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 07-0815.06
d y Expiration Date: 11/08/11
Approval Date:11/08/07
Page 1 of 5
ROOFING SYSTEM APPROVAL
Category
Roofing
Sub -Category:
Nan -Structural Metal Roofing
Material:
Steel
Maximum Design Pressure: ' -154.75 psf.
s
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product
Dimensions
Test Specifications
Product Dmili tion
Length: various
Corrosion resistant,
5V Crimp Metal Roof
Height : 7/16"
TAS 125
galvalume or galvanized
Panels
Width: 25-V2"
performed, coated, pre -
(Coverage width: 24")
finished, metal panels.
Thickness: 0.0217
EVIDENCE SUBMITTED:
TestA¢env
Test Identifier
Test Name/Reoort
Date
Farabaugh
T270-07
TAS-100
08/24/07
' Engineering and
Testing, Inc.
Farabaugh
T166-07
TAS-100
04/15/07
Engineering and
Testing, Inc.
Force Engineering &
188-0331T-06A-C
TAS-125
02/26/07
Testing, Inc.
Hurricane Test
0041-0906-07
TAS-125
09/12/07
Laboratory, LLC.
BASF
Accelerated
ASTM G 154
07/12/07
Weathering
BASF
Salt Spray
ASTM B 117
07/12/07
NOA No.: 07-0815.06
.-flm
Expiration Date: 11/08/11
`
Vj
Approval Date: 11/08M
Page 2 of 5
APPROVED ASSEMBLY:
System: "SV-Crimp" Metal Panels
Deck Type:
i Deck Description:
Slope Range:
Maximum Uplift
Pressure:
Wood, Non -insulated
19/32" or greater plywood or wood plank.
2": 12" or greater
See Table A Below
Deck Attachment: In accordance with applicable building code, but in no case it shall be less than 8d
annular ring shank nails spaced at 6" o.c. In re -roofing, where deck is less than
19/32" thick (minimum 15/32") the above attachment method must be in addition to
existing attachment.
Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a
minimum 4" side -lap and 6" end -laps. Underlayment shall be fastened with
contusion resistant tin -caps and 12 gauge IJ/4" annular ring -shank nails, spaced 6"
o.c. at all laps and two staggered rows 12" o.c. in the field of the roll. Or, any
approved underlayment having a current NOA.
Valleys: Valley construction shall be in compliance with Roofing Application Standard
RAS 133 and with current published installation instructions and details in
Southeastern Metal Manufacturing Metal Roofing Installation Manual.
Fire Barrier
Board:
Any approved fire barrier
resistant type X gypsum sheathing with treated core and facer.
Metal Panels and Install the "5V-Crimp Panels" and accessories in compliance with the current
Accessories: published installation instructions and details in Southeastern Metals
Manufacturing Company's Installation Manual. Flashings, penetrations, valley
construction and other details shall be constructed in compliance with Roofing
Application Standard RAS133.
1. At the eave, rake, and ridge, fasteners shall be located not more than 3" away
from the panel end.
2. The leading side edge of the panel should be the side with the anti -siphon
groove; each panel side will overlap this channel to provide a capillary brake.
3. The panels shall be fastened with #9 x 2" metal roofing sealing washer screws
in the crown of the inverted V ribs as shown in the details herein.
4. The panel's width fasteners shall be spaced at 11 W1 to the center rib, Then 12
Y2" to the next, perpendicular to the slope, through the overlapping panel. The
flat area of the panel as shown in the details herein.
5. The panels fastening pattern at the interior of the panel, shall be in rows spaced
as listed in Table A below, running parallel to the slope of the roof.
Table A
Maximum Des Pressure
Field
Perimeter and Cornee
Maximum Design Pressure
-6715psf.
-154.75 psf
Maximum Fastener Fastener S
16' O.C.
8" ox-
1. E=WMon shall not be allowed
NOA No.: 07-0815.06
Expiration Date: 11AWII
Approval Date: 11/ MW
Page 3 of 5
" 5-V CRIMP' METAL ROOF PANELS
251/2"
t • I � � 111/2" 121/2"
7fl6"
FASTENING PATTERN FOR 5V-CRIMP AT INTERIOR OF PANEL
FASTENING PATTERN FOR 5V-CRIMP AT EAVE & RIDGE
SeeTable A
NOA No.: 07-0815.06
o Expiration Date: 11MB/11
Approval Date: 11/08/07
Page 4 of 5
SYSTEM LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofmg Materials
Directory for fire ratings of this product.
2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e.
field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and corners).
3. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following
statement: "Miami -Dade County Product Control Approved.
4. All products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code and Rule 9B-72 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 07-0815.06
Expiration Date: 11AM11
Approval Date:11/08W
Page 5 of 5