HomeMy WebLinkAboutNOA; Georgia-Pacific Gypsum Board, Dens Deck4
V
M I A M I-DADE
BUILDING CODE COMPLIANCE OFFICE (BCCO)
PRODUCT CONTROL DIVISION
NOTICE OF ACCEPTANCE (NOA)
Georgia-Pacific Corporation
2861 Miller Road
Decatur, GA 30035-4036
MIAMI-DADE COUNTY, FLORIDA
METRO-DADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130-1563
(305) 375-2901 FAX (305) 375-2908
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building
-- - de and P-ea, et Review Gem e-to-be omriy-and-otherareas-where allowed
by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County)
and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material
tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,
the manufacturer. will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. BCCO reserves the right to revoke
this acceptance, if it is determined by BCCO that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code and the High Velocity I ene-dfi en it ' Code.
DESCRIPTIONS rgia- acific Gypsum Board, Dens Deck®
RENEWAL of this N-be-se8sidered-aftera-reneva-ap�n has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate
this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA Renews NOA No. 04-1223.01 and consists of pages 1 through 5.
The submitted documentation was reviewed by Jo r e L. Acebo.
A No: 07-0124.02
` b � COPYPI;
on Date: 02/14/12
FILE al Date: 03/29/07
. Page 1 of 5
ROOFING COMPONENT APPROVAL
Cateaory• Roofing
Sub -Category: Insulation and Sheathing Panels
Materials: Gypsum
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product Dimensions
Test Product Description
Specifications
Dens -Deck ®, Dens -Deck 4' x 8' x'/4"
TAS 110 A non-structural, glass mat faced gypsum
Prime® & Dens Deck 4' x 4' x'/4"
product with a silicone -treated, water
DuraGuardTM
resistant gypsum core and glass surface
_ Overlavment Roar _.__ .....
Ieng-edges; the
primed board has one side coated with an
acrylic limestone filled binder; for use as
an overlayment, underlayment, bonding
surface or fire barrier.
Dens -Deck®, Dens -Deck 4' x 8' x'/z"
TAS 110 A non-structural, glass mat faced gypsum
Prime® & Dens Deck 4' x 4' x'/z"
product with a silicone -treated, water
DuraGuardTM Roof Board
resistant gypsum core and glass surface
mats front, back and long edges, the
primed board has one side coated with an
acrylic limestone filled binder; for use as
an overlayment, underlayment, bonding
surface or fire barrier.
Dens -Deck®, Dens -Deck 4' x 8' x 5/8"
TAS 110 A non-structural, glass mat faced gypsum
Prime® & Dens Deck 4' x 4' x 5/8"
product with a silicone -treated, water
DuraGuardTM Fireguard®
resistant gypsum core and glass surface
Type X Gypsum Board
mats front, back and long edges, the
primed board has one side coated with an
acrylic limestone filled binder; for use as
an overlayment, underlayment, bonding
surface or fire barrier.
p NOA No: 07-0124.02
Expiration Date: 02/14/12
Approval Date: 03/29/07
Page 2 of 5
TYPICAL PHYSICAL PROPERTIES:
Property
Test
'/a" Dens Deck,
%:" Dens Deck,
5/e"Dens Deck,
Prime &
Prime &
Prime &
DuraGuard
DuraGuard
DuraGuard
Weight, lbs. / M ft2 nom.
1100
1975
2500
�. Flexural Strength:
ASTM C 473
Parallel lbs. min.
40
80
100
Perpendicular, lbs. min.
50
100
140
Flute Spanability
ASTM E 661
2 5/8"
5"
8"
....
Permeance, perms for
............ -- .
ASTM E 96
--- -...._ ......._.
50
35
32
Dens Deck & Prime
Permeance, perms for
ASTM E 96
< 5
< 5
< 5
DuraGuard
"R' Value
ASTM C 518
0.28
0.56
0.67
Coefficient of
10 x 10-6
10 x 10-6
10 x 10-6
Expansion,
inches/inch/°F
w Nail Pull Resistance,
ASTM C 473
40
80
90
lbs. force, min.
Core Hardness, lbs. min
ASTM C 473
15
15
15
Edge Hardness, lbs. min
ASTM C 473
15
15
15
Absorption, % max.
ASTM C 473
10
10
10
Compression, psi, max.
1500
900
900
load
Humidified Deflection,
ASTM C 473
N/A
'/4"
'/s"
inches
Surface Water
ASTM C 473
< 2.5
2.5
2.5
Resistance, grams
UL Fire Resistance
UL Class A
UL Class A
UL Class A
Classified
UL 1256
UL 1256
UL 1256 &
°
Type DD'
Surface Burning
ASTM E 84
0
0
0
Characteristics:
Flame spread &
Smoke Developed
1 For use in UL "P" designs where either'/2" or 5/8" thick gypsum wallboard is specified.
NOA No: 07-0124.02
Expiration Date: 02/14/12
Approval
Date: 03/29/07
Page 3 of 5
PHYSICAL PROPERTIES OF COMPONENTS:
Tradename: Dens -Deck, Prime & DuraGuard Overlayment
Thickness: Minimum'/4" thick
Board Size(s): 4' x 8' (1.2 x 2.4m) 4' x 4' (1.2 x 1.2m)
Core: Gypsum
Facers: Fiberglass mat
Decks: Concrete, Cementitious Wood Fiber; Steel, Wood, Lightweight Concrete,
Gypsum
Special Application: Dens -Deck, Prime and DuraGuard may be secured with ASTM D 312 type III
asphalt at an application Rate of 25 lbs./sq. + 15%, or by mechanical
attachment. Maximum board size for asphalt securement is 4' x 4'.
Tradename: Dens -Deck, Prime & DuraGuard Roof Board
Thickness: Minimum''/z" thick
Board Size(s): 4' x 8' (1.2 x 2.4m) 4' x 4' (1.2 x 1.2m)
Core: Gypsum
Facers: Fiberglass mat
Decks: Concrete, Cementitious Wood Fiber, Steel, Wood, Lightweight Concrete,
Gypsum
Special Application: Dens -Deck, Prime and DuraGuard may be secured with ASTM D 312 type III
asphalt at an application Rate of 25 lbs./sq. + 15%, or by mechanical
attachment. Maximum board size for asphalt. securement is 4' x 4'.
Tradename: Dens -Deck, Prime & DuraGuard Fireguard Roof Board
Thickness: Minimum 5/8" thick
Board Size(s): 4' x 8' (1.2 x 2.4m) 4' x 4' (1.2 x 1.2m)
• Core: Gypsum
Facers: Fiberglass mat
Decks: Concrete, Cementitious Wood Fiber, Steel, Wood, Lightweight Concrete,
Gypsum
Special Application: Dens -Deck, Prime and DuraGuard may be secured with ASTM D 312 type III
^, asphalt at an application Rate of 25 lbs./sq. + 15%, or by mechanical
attachment. Maximum board size for asphalt securement is 4' x 4'.
Aflts NOA No: 07-0124.02
Expiration Date: 02/14/12
Approval Date: 03/29/07
Page 4 of 5
it.
Is
EVIDENCE SUBMITTED
Test Aiency/Identifier
Factory Mutual
Research Corporation
Underwriters
Laboratories, Inc.
PRI Asphalt
Technologies, Inc
Name
4450
4450
4450
4450
4450
4450
4450
Fire Classification
Fire Classification
Fire Classification
Fire Classification
Static Uplift TAS 101
Report
J.I.# 1N2A6.AM
J.I.# OY8A9.AM
3003782
3004417
3009125
3011494
3018578
R2717
R15206
OONK50350
OINK3902
GPGC-002-02-01
GPGC-002-02-02
GPGC-002-02-03
GPGC-003-02-01
GPGC-003-02-02
GPGC-003-02-03
GPGC-004-02-01
GPGC-004-02-02
GPGC-005-02-01
Date
07/21/87
08/30/94
06/11/99
12/28/99
07/30/01
08/22/01
09/14/04
08/29/89
08/23/06
01/10/94
01/19/04'
04/02/01
04/12/01
04/02/01
04/12/01
05/26/04
05/26/04
05/26/04
06/28/04
06/28/04
06/28/04
06/23/04
06/24/04
07/26/04
COMPONENT APPLICATION:
''/4" '/2" Dens Deck. Prime & DuraGuard Roof Board. '/,,"Dens Deck Prime & DuraGuard Fireguard
l . Refer to specific roof assembly NOA for minimum dimensions and for type and pattern of
mechanical attachment, and/or adhesive.
2. Fastening Patterns shall be a minimum of 16 insulation fasteners and plates per 4' x 8' panel
(1:2 ftz), unless otherwise specified in Roof Assembly NOA.
COMMENTS AND LIMITATIONS:
1. Georgia-Pacific products are components used in approved roof assemblies.
2. Georgia-Pacific products may be used with any approved roof assembly NOA listing a specific
Georgia-Pacific product as a component part of an assembly. If a Georgia-Pacific product is not
listed, a request may be made to the Building Official or the Miami -Dade Office of Building
Code Compliance Product Control Division for approval provided that appropriate
documentation is provided.
END OF THIS ACCEPTANCE
t NOA No: 07-0124.02
Expiration Date: 02/14/12
Approval Date: 03/29/07
Page 5 of 5