Loading...
HomeMy WebLinkAboutProject Informationt Earl A Schuler Load Short Form ob: 2008-06-030-008 PYEy: ate: Jun 30, 2008 Design Calcs Plus Ent/re HouseFW-' C 0 Eari A. Schuler Lam"' ` • • • For: Lot 150 Venture Out, St. Lucie County, Poineer Coolint & Heating, Inc. FL Design Information Htg Clg Infiltration ` Outside db (OF) 42 90 Method Simplified Inside db (OF) 70 75 Construction quality Average Design TD (OF) 28 15 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference (gr/lb) 23 61 HEATING EQUIPMENT COOLING EQUIPMENT Make Trane Make Trane Trade XR14 Weathertron Trade XR14 Weathertron Model 4TWR4024C1 Cond 4TWR4024C1 Coil 4TEH3F30B1 Efficiency 8.5 HSPF Efficiency 14 EER Heating input Sensible cooling 16800 Btuh Heating output 24000 Btuh @ 470F Latent cooling 7200 Btuh Temperature rise 27 OF Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.081 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0.00 in H2O Static pressure 0.00 in H2O Space thermostat Load sensible heat ratio 0.85 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ftz) (Btuh) (Btuh) (cfm) (cfm) Bath 2 98 1045 751 85 35 BedRoom2 138 1367 1812 111 84 Dining Room 70 1325 2018 108 93 Kitchen 147 1230 4853 100 225 Bath 1 51 185 158 15 7 BedRooml 183 1667 3451 135 160 Living Room 164 3032 4245 246 196 Entire House d 851 9851 17288 800 800 Other equip loads 114 61 Equip. @ 0.95 RSM 16482 Latent cooling 3040 TnTAI S ncnn Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 1-Fk wr ightsoft` Right -Suite Residential 6.0.119 RSR43233 2008-Aug-13 15:58:13 ACC& C: y DocumentslWrightsoft HVAC1Projects12008 ProjectslLot 150 Venture Out Saint Lucie-2008-08-013- Page 1 EarlA Schuler Building Analysis Design Calcs Plus Entire House Job: 2008-06-030-008 Date: Jun 30, 2008 By: Earl A. Schuler Project Inf• • . For: Lot 150 Venture Out, St. Lucie County, Poineer Coolint & Heating, Inc. FL Location: Indoor: Heating Cooling Fort Pierce, FL, US Indoor temperature (OF) 70 75 Elevation: 25 ft Desiggn TD CF) 28 15 Latitude: 270N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 23.2 61.5 Dry bulb (OF) 42 90 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (OF) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heating, Component Btuh/ft2 Btuh % of load Walls 0.0 0 0.0 Glazing 35.6 3700 37.1 Doors 16.8 706 7.1 Ceilings 0.9 761 7.6 Floors 0.0 0 0.0 Infiltration 2.2 2130 21.4 Ducts 2555 25.6 Piping 0 0.0 Humidification 0 0.0 Ventilation 114 1.1 Adjustments 0 Total 1 1 9964 100.0 Coolin Component Btuh/ft2 Btuh % of load Walls 0.0 0 0.0 Glazing 71.2 7412 42.7 Doors 17.4 731 4.2 Ceilings 2.3 1970 11.4 Floors 0.0 0 0.0 Infiltration 0.6 599 3.4 Ducts 3718 21.4 Ventilation 61 0.4 Internal gains 2860 16.5 Blower 0 0.0 Adjustments 0 Total 17349 100.0 Overall U-value = 0.069 Btuh/ft2-01= Data entries checked. 1M wrightsoTt- Right -Suite Residential 6.0.119 RSR43233 2008-Aug-1315:58:13 ACCA C: y Documents\wrightsoft HVAC\Projects\2008 Projects\Lot 150 Venture Out Saint Lucie-2008-08-013- Page 1 Earl A Schuler Component Constructions Design Calcs Plus Entire House Job: 2008-06-030-008 Date: Jun 30, 2008 By: Earl A. Schuler ^ • ect Information. For: Lot 150 Venture Out, St. Lucie County, Poineer Coolint & Heating, Inc. FL Design Conditions Location: Fort Pierce, FL, US Indoor: Indoor temperature (OF) Heating 70 Cooling 75 - Elevation: 25 ft Latitude: 270N Design TD (OF) Relative humidity (%) 28 50 15 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 23.2 61.5 Dry bulb (OF) 42 90 Infiltration: Daily range (OF) Wet bulb (OF) - 15 ( L - 78 ) Method Simplified Wind speed (mph) 15.0 7.5 Construction quality Fireplaces Average 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Stuh/fR T ft'-°F/Btuh Btuh/W Btuh BtuhRN Btuh Walls 51 B: 2.5'Foam/6"Cmnt/2.5"Foam ne 287 0.000 25.0 0.00 0 0.00 0 se 120 0.000 25.0 0.00 0 0.00 0 sw 250 0.000 25.0 0.00 0 0.00 0 w 98 0.000 25.0 0.00 0 0.00 0 nw 56 0.000 25.0 0.00 0 0.00 0 all 812 0.000 25.0 0.00 0 0.00 0 Partitions (none) Windows 1A-c1om: Operable, metal frame, no break, clear glass, 1 pane; 1 ft ne 35 1.270 0.0 35.6 1239 70.4 2453 overhang (5.5 ft window ht, 1 ft sep.) se 35 1.270 0.0 35.6 1239 65.1 2267 sw 17 1.270 0.0 35.6 603 65.1 1104 w 17 1.270 0.0 35.6 619 91.1 1587 all 104 1.270 0.0 35.6 3700 71.2 7412 Doors 11JO: Metal door, fiberglass core, no storm se 22 0.600 0.0 16.8 372 17.4 386 nw 20 0.600 0.0 16.8 333 17.4 345 all 42 0.600 0.0 16.8 706 17.4 731 Ceilings 16A-30mi: Ceiling under unvented attic, no radiant barrier, light 849 0.032 30.0 0.90 761 2.32 1970 metal, R-30 insul. Floors 91A: Wood Frame R-22 849 0.000 22.0 0.00 0 0.00 0 , �-rig htsoft- Right -Suite Residential 6.0.119 RSR43233 ACCA C: y Document.1 rightsoft HVAC1Projects12008 ProjectslLot 150 Venture Out Saint Lucie-2008-08-013- 2008-Aug-13 15:58:13 Page 1 Earl A Schuler Project Summary Design Caics Plus Entire House Project Information Job: 2008-06-030-008 Date: Jun 30, 2008 By: Earl A. Schuler For: Lot 150 Venture Out, St. Lucie County, Poineer Coolint & Heating, Inc. FL Notes: All computed results are estimates as building use and weather may vary. Data supplied by the customer has been entered according to Manual-J 8th Edition guidelines. Design Information' Weather: Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Summer Design Conditions 42 OF Outside db 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 7296 Btuh Ducts 2555 Btuh Central vent (4 cfm) 114 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 9964 Btuh Infiltration Method Construction quality Fireplaces Area (ft2) Volume (ft3) Air changes/hour Equiv. AVF (cfm) Simplified Average 0 Heatin Cooling 6808 6808 0.6G9 0 36 90 OF 75 OF 15 OF 50 % 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 13570 Btuh Ducts 3718 Btuh Central vent (4 cfm) 61 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier Equipment sensible load 0.95 16482 Btuh Latent Cooling Equipment Load Sizing Structure 1917 Btuh Ducts 969 Btuh Central vent (4 cfm) 154 Btuh Equipment latent load 3040 Btuh Equipment total load 19522 Btuh Req. total capacity at 0.70 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade XR14 Weathertron Trade XR14 Weathertron Model 4TWR4024C1 Cond 4TWR4024C1 Coil 4TEH3F30B1 Efficiency 8.5 HSPF Efficiency 14 EER Heating input Sensible cooling 16800 Btuh Heating output 24000 Btuh @ 47°F Latent cooling 7200 Btuh Temperature rise 27 OF Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.081 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0.00 in H2O Static pressure 0.00 in H2O Space thermostat Load sensible heat ratio 0.85 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. -Ftiwrightsc ft- Right -Suite Residential 6.0.119 RSR43233 2008-Aug-13 15:58:13 , =k CAMy DocumentsUrightsoft HVAC1Projects\2008 Projects1ot 150 Venture Out Saint Lucie-2008-08-013- Page 1 AED Assessment Job: 2008-06-030-008 Earl A Schuler Date: Jun 30, 2008 Design Calcs Plus Entire House By: Earl A. Schuler Pebject lfif&mation' For: Lot 150 Venture Out, St. Lucie County, Poineer Coolint & Heating, Inc. FL Design Co1b'ditions Location: Indoor: Heating Cooling Fort Pierce, FL, US Indoor temperature (OF) 70 75 Elevation: 25 ft Design TD (OF) 28 15 Latitude: 270N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 23.2 61.5 Dry bulb (OF) 42 90 Infiltration: Daily range (OF) - 15 ( L ) Wet bulb (OF) - 78 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity 9 Hourly Glazing Load c y 1U 11 12 13 14 15 16 17 18 19 20 Hour of Day / Hourly / Average / AED limit Maximum hourly glazing load exceeds average by 18.7%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh a -F14- wrightsoft' Right -Suite Residential 6.0.119 RSR43233 2008-Aug-13 15:58:13 C:Wy Documents%Wrightsoft HVAC1Projects12008 ProjectslLot 150 Venture Out Saint Lucie-2008-08-013- Page 1 Earl ASchuler Right-J Worksheet Job: 2008-06-030-008 Design Calcs Phis Entire House Date: Jun 30, 2008 By: Earl A. Schuler 1 Room name Entire House Bath 2 2 Exposed wall 119.7 ft 19.8 ft 3 Ceiling height 8.0 ft d 8.0 ft heat/cool 4 Room dimensions 9'5 x 10.3 ft 5 Room area 851.0 ft2 98.2 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter ft () (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 IWI __, 51,B 0.000 ne 0:00 0.00 83 ^ 83 0 0 !, C _1 ,,clom..._ _ _. 1.270, , ne , 35.56 70.43 : ,.35 _ .0.... 1239 _ 2453: W 51B 0,000 se 0.00 0.00 177 120 0 0 _. 0 0 0 0 1A-clam 1.270 se 35.56 70.95 35 6 1239 2267 0 0 0 0 11 11,10 0.600 -0.000 se 16.80 17.40 22 22 372 386 0 0 0 0 Wj 516 sw 0"00 000 267 250 0 '0 _ _ 0 0 - ' 0 - 0 !—C' 18c1om 35°56. 7-0,95 �i `G 51 B igc1orp 0.000 w 0.00 0.00 115 98 0 0 0 0 0 0 518 w_11J0 1.270 0.000 0:600 w., nw" 3556 OAO 91,12 0.00 17 76 0 56 619 ; 0' 1587 , . 0 0 ° 76 0, 56 0 J 0 0 "0 _i nw._ .16.d0 _ 17.40 20 20 333 345, ._ 20, : 20, 3.45. C _ M 16A_30m1_ _ _,. 2.32 849 849_ 761_ 1970 98 98 _ _333 88 228 F = .w q91 A'_ , a... ,.. __..._. :a0.000'' . ° ... 0:00. , : ' ^ 0.60 : , _ '849 ', :120... , 0 ' . 0 98 . _ 6 c) AED excursion 0 -83 Envelope losstgain 5166 10112 421 490 12 a) Infiltration b) Room ventilation 2130 599 353 99 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances @ 1200 2 2400 0 0 Subtotal (lines 6 to 13) 7296 13570 774 589 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 15 Subtotal Duct loads 7296 13570 774 589 35% 27% M 2555 3718 35% 27% 271 161 Total room load 9851 17288 1045 F 751 Air required (cfm) 800 8001 1 85 35 Printout certified by ACCA to meet all requirements of Manual J 8th Ed ,Q= wr:ghtsoft Right -Suite Residential 6.0.1:13 19 RSR43233 2008-Aug-13 15:58 ACCA. C: y Documents\Wrightsoft HVAC\Projects\2008 Projects\Lot 150 Venture Out Saint Lucie-2008-08-013- Page 1 Earl A Schuler Right-J Worksheet Job: 2008-06-030-008 Design Calcs Plus Entire House Date: Jun 30, 2008 By: Earl A. Schuler 1 Room name BedRoom2 Dining Room 2 Exposed wall 15.2 ft 16.8 ft 3 Ceiling height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 137.8 ft 9.5 x 7.4 ft 5 Room area 137.8 ft' 70.5 ft2 Ty Construction U-value Or HTM Area (W) Load Area (ft� Load number (Btuh/W °F) (Btuh/ft') or perimeter (ft) (Btuh) or . perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 ,W 516 ... _ . 0 000 ne 0 0 0.00 921 104 1' 27.0 ,;ne.. ._35 56. , r. 70:43 ! 17 0 619 ; 1227 .,' 0 , ,0 0 W 51 B 0.000 se 0.00 0.00 0 0 0 0 76 59 0 _0 0 IA-clom 1.270 se 35.56 70.95 0 0 0 0 17 3 619 1134 11 111,10 0.600 se 16.80 17.40 0 0 0 0 0 0 0 0 0;00 0.00 0 _ .. 0 - 0 - - 0 - 59 - 69 _.. _ _. -0 ; 0 1,270.. sw 35.56 70 95 __ . .. _ . 0 ; :0 .0 9 0. 0 0 W, 51 B 1A 0.000 w 0.00 0.00 0 0 0 0 0 0 _ 0 0 c1om 1 270 w 35.56 91.12 .. 0 0 0 0 0 0 0 0 Vi !-D, 51 B 11JQ_ ` 0 000 0 600 nw 0.o0 0.00 0 0 0 0 0 0 0` 0 . nw. 16.80. 17,40 : 0 0. 0 0: 0 . 0 0.... 0 C_,_. 16A-30m1 _ 0032 - 0.90 _ 2.32, 138. 1.38 123, 320 70 70 62 .. 162 F __ ,91A ._ -0.0001 - 000. 0.00..' 138 15. 0 0 70. _ 17. _ 0. 0. 6 c) AED excursion -200 205 Envelope loss/gain 743 1346 682 1500 12 a) Infiltration 270 76 299 84 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 10 0 0 Subtotal (lines 6 to 13) 1013 1422 981 1584 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1013 1422 981 1584 15 Duct loads 35% 27% 355 390 35% 27% 344 434 Total room load 1367 1812 T1325 2018 Air required (cfm) 111 84 108 93 Printout certified by ACCA to meet all requirements of Manual J 8th Ed wrightsoft- Right -Suite Residential 6.0.119 RSR43233 2008-Aug-13 15:58:13 ACCA C: y DocumentsUrightsoft HVACtProjects12008 ProjectsIot 150 Venture Out Saint Lucie-2008-08-013- Page 2 Earl ASchuler Right-J Worksheet Design Calcs Plus Entire House Job: 2008-06-030-008 Date: Jun 30, 2008 By: Earl A. Schuler 1 Room name Kitchen Bath 1 2 Exposed wall 9.9 ft 5.2 ft 3 Ceiling height 8.0 ft heat/cool 8.0 ft heat1cool 4 Room dimensions 1.0 x 146.7 ft 9.8 x 5.3 ft 5 Room area 146.7 ft' 51.2 ftz Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft? °F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 w '- 51 B 0.666 •ne 0.00 0.00 0 0 0 0 0- 0 0 0 1A c1.om; _ _ , _. _ ;1.27.0 ne 3.5:56 . 70.43 , 0 _ 0 0 0; 0 0 0 _ w 51 B 0.000 se 0.00 0.00 0 0 0 0 0 0 0 0 1A-c1om 1.270 se 35.56 70.95 0 0 0 0 0 0 0 0 11 11,10 0.600 se 16.80 17.440 0 0 0 0 0 0 0 0 w UN 51 B 0.000 sw 6.00 0.00 79 62 0 0 41 41 LL 0 V 0 ®_- JA-c1om-____.___-,.__-_ __-1.27.0 .sw_ _ 35,56 70,95, _-. _.17 .. _, .. A- 603 .. . 1104. 0. -0. W 51 B 0.000 w 0.00 0.00 0 0 0 0 0 _.0 0 0 0 1.270 , w 35.56 0,'. 0. 0. 0 0 0 0 V 51 B 11 J0. 0 000 hw, 00'0 ,91J4 0.00 .01 , 0 _ , , 0 - 0 6 0 6 _ 0 _ 0 �D _ 0.600 0.032. , nw , - 16.80 0.90. 17.40 2..32 0 , 147 0. 14T _ 0. - 131- 0 0 50 0, 50, 0 4.5 0 116. F. :` : 91A _ ..... 0.000 ., - ; . 0.00, . -, 0.00 147, 10 0. ,340 Q 56 5 0- - 0 6 c) AED excursion -85 -17 Envelope loss/gain 735 1360 45 98 12 a) Infiltration 176 50 92 26 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 2 2400 0 0 Subtotal (lines 6 to 13) 911 3809 137 124 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 911 3809 137 124 15 Duct loads 35% 27% 319 1044 35% 27% 48 34 Total room load 1230 4853 185 158 Air required Wm) 100 225 15 7 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr:gr.tsote^ Right -Suite Residential 6.0.119 RSR43233 2608-Aug-13 15:58:13 AMN CAMy Documents\wrightsoft HVAC1Projects12008 Projects\Lot 150 Venture Out Saint Lucie-2008-08-013- Page 3 Earl ASchuler Right-J Worksheet Job: 2008-06-030-008 Design Calcs Plus Entire House Date: Jun 30, 2008 By: Earl A. Schuler 1 Room name BedRooml Living Room 2 Exposed wall 25.3 ft 27.4 ft 3 Ceiling height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 182.6 ft 1.0 x 164.0 ft 5 Room area 182.6 ftZ 164.0 ftZ Ty Construction U-value Or HTM Area (ftZ) Load Area (ftZ) Load number (Btuh/ftZ-*F) (Btuh/ftZ) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 51 B - 0,000 ne 0.00 -_3.5,56„ 0.00 0 0 '0 0' 116 101 0 _ 0 IL ,!A-clom_ . . 1 270 ,,ne , , 7,0.43 : 0 0 0 ` 0 1 ;17. ,. -0 ;_, 619 1227, W ED 51 B 1A-clom 0.000 1.270 se se 0.06 35.56 0.00 70.95 0 0 0 0 0 0 0 0 101 17 62 3 . 0 619 ., . . 0 1134 i 11,10 0.600 se 16.80 17.40 0 0 0 0 22 22 372 386 �-G b 000 'sw 0 00 0.00 ` 88 88 0, `. 0 0 0 0 0 1A-c1om. 1 270 sw. 35 56 70.95 Q . b: 0 . 0' : 0 0 , 0 0, 51 B 1A 0.000 w 0.00 0.00 115 98 0 0 0 0 _ 0 0 c1om _ r , 1,270 w.. 35 56 91.12 _ -17 „ 0, 619 1587 0 0 0 0 �j D 51 B 1110__._ 0 000 • nw 'nw_ 6.00 6.00 0 6 0 0 0' , 0 , 0 _ 0 ----- .. 0 600, 18:80 17:40 . 0 0 .0 0 ;_ 0. 0 0- 0 0.032 , . - 0.90 2.32 183 183 164 424, 164 164, 147 380, F _. 91A_.... :; " 0.000: - 0.00 0.00, 183' 25' 0, 0, 164.. ., 27.' , 0. Q 6 c) AED excursion 341 -161 Envelope loss/gain 783 2352 1758 2965 12 a) Infiltration 452 127 488 137 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 1 230 Appliances @ 1200 0 0 0 0 Subtotal (lines 6 to 13) 1235 2709 2246 3332 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal Duct loads 35% 27% 1235 432 2709 742 35% 27% 2246 786 3332 913 r Total room load 1667 3451 3032 4245 Air required (cfm) 135 160 1 1 246 196 Printout certified by ACCA to meet all requirements of Manual J 8th Ed wr:gr.tsofeW Right -Suite Residential 6.0.119 RSR43233 2008-Aug-13 15:58:13 ACCp, C:\My Documents%Wrightsoft HVAMProjectM2008 ProjectslLot 150 Venture Out Saint Lucie-2008-08-013- Page 4