HomeMy WebLinkAboutFulmer LetterArchitectonic Inc
City of Fort Pierce Building Department
100 North US 1
Fort Pierce, FL
September 10, 2020
RE: Fulmer Residence
3820 Delaware Avenue
To Whom It May Concern:
Our office has performed design pressure calculations for the above referenced project and herby certify
that the proposed Single Hung Aluminum Impact Window is incompliance with the 2017 Florida Building
Code, 160 mph wind zone, exposure "C", risk category II.
Exposure "C" Multiplier for 20' mean roof height is 1.21
Wind Zone 4 28 x 1.21 = 33.88
Wind Zone 5 34 x 1.21 = 41.14
Required Design Pressures: +/-41.14
Product: SH 7700A, NOA# 20-0401.11, PGT Industries
Product Pressures: +80/-110
806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com
Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1