Loading...
HomeMy WebLinkAboutAPPROVED,Design pressure calcsNewSouth W I N DOW SOLUTIONS 9596 Okeechobee Blvd. West Palm Beach, FL 33409 • 561-712-9000 • CRC1330822 Information Owner. Clarke & Beverly Mangan Address: 406 Banana Ln Ft Pierce, FL 34982 Information Wind Zone: 170 MPH. Exposure Category: C Minimum Building Dimension: 25 ft. Mean Roof Height: 15 ft. Risk Category: 11 Desi n Pressure Calculations Opening Number Location Zone Device Width (in) Device Device Height (in) Elevation (ft) Max Positive Pressure (psi) Max Negative Pressure (psf) 1 Int 73 61.75 7 35.0 38.2 2 Int 36 61.75 7 36.7 39.9 3 Int 52 37 7 37.1 40.3 4 Int 110 55 7 34.3 37.5 5 Int 25.50 49.50 7 37.8 41.0 6 Int 25.50 49.50 7 37.8 41.0 7 Int 25.50 37 7 37.8 41.0 8 Int 52 55 7 36.1 39.3 Prgwa in ordmm with: ASCE7-10, awpf 30. WhdLoadt-CamponnKr andCla"ng. 6th Mfion(2017)FlwldaBWMWCode. Page 1 of I