HomeMy WebLinkAboutAPPROVED, 5V CrimpCompliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61620-3
Compliant Active Qual ity Assurance Program
Product: Min. 26GA SV Crimp Roof Panel FBC Sec.1507.4.2
Yield strength: S0ksi 24" Cov erage (Max.) Rib Height 3/8"
Minimum 15/32" plywood over supports at maximum 24" O.C. Design of plywood
and plywood supports are outside the scope of this evaluation. Must be designed
in accordance w/ Florida Building Code 2017.
¼" penetration thru plywood supports 24" max. o.c.
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener: #10-15 Woodtite fastener spaced @ 12" O.C.
Underlayment: To be compliant with FBC Sec. 1507, Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1S07.
Install Details: Table A Allowable Method 1:
Loads
DESIGN PRESSURE* -116PSF
SPACING 12#0,C.
Reference Data:
lntertek Testing (TST-1527) REPORT# l7226.03-4So-44 RO ULSB0-06
*Design Pressure safety margin of 2:1
**This test is owned by Quality Metal Fabricators, who has given permission to share testing.
Certificate of Independence:
Locke Bowden, P.E. does not have, nor will acquire a financial Interest in any company manufacturing or distributing products
under this evaluation. k: Locke Bowden, P.E. Is not owned, operated, or controlled by any company, manufacturer, or distributing r.fflYfn under tireport. ,,,,,,,, .' �,,,,,, '; f (. -,
,,,l� Q • ,��
�'('� .:-�.· . �
.:-, :: 04 • �. yf t-'O-497 ••.. ;
-. � . .: •"""•er=a �· • C ■4.1:
� .J'\ • t-·a,J( Or • !-iJ .:�-v • ;,11" •� � \�o••• /:LQR\'v!••�,/
... ., �� ...... �� .... ... ... ,,,,,ss,oN�\. ,\,..,.,, ''''•um�,\\\\
Limitations:
1.Underlayment to be compliance with current Florida Building Code (FBC)2017 6TH ed.. see Chart 1507.1.1
2.Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer’s installation reference.
3.Products are compliant with State of Florida product approval per Rule 61G20‐3. Compliance Method: 1‐D
4.Engineering analysis for “project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5.Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6.Support framing in compliance w/FBC 2017 6th ed., Chapter 22 Steel, Chapter 23 Wood and Chapter 16 Structural Loading.
7.This report does not imply warranty, installation, recommended product use outside of this report.
Integrity Metals Min. 26GA 5V Crimp Roof Panel Installation Details
PROFILE
3/8"
FASTENER PATTERN @ 12" O.C.