HomeMy WebLinkAboutComcheck_ElecCOMcheck Software Version 4.1.2.2 Interior Lighting Compliance Certificate Project Title: 90.1 (2016) Standard Project Type:Alteration Construction Site: 200 S Kings Hwy Fort Pierce, FL 34945 Owner/Agent: Loves Designer/Contractor: HFA Project Information Energy Code: Customer Laundry Addition Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 2-Hallway (Common Space Types:Corridor/Transition <8 ft wide)70 0.66 46 1-Customer Laundry (Common Space Types:Laundry/Washing Area)240 0.43 103 149Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Hallway ( Common Space Types:Corridor/Transition <8 ft wide 70 sq.ft.) A1/A1E: Other:1 2 32 64 Customer Laundry ( Common Space Types:Laundry/Washing Area 240 sq.ft.) A1/A1E: Other:1 2 32 64 128Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 90.1 (2016) Standard requirements in COMcheck Version 4.1.2.2 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES Project Title: Data filename: Customer Laundry Addition M:\03\03-19-11467 Loves - Fort Pierce, FL 467\DESIGN\comcheck\comcheck.cck 09/11/20Report date: 61 ofPage COMcheck Software Version 4.1.2.2 Exterior Lighting Compliance Certificate Project Title: 90.1 (2016) Standard Project Type:Alteration Construction Site: 200 S Kings Hwy Fort Pierce, FL 34945 Owner/Agent: Loves Designer/Contractor: HFA Project Information Energy Code: Customer Laundry Addition 3 (Other)Exterior Lighting Zone Allowed Exterior Lighting Power A Area/Surface Category B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts (B X C) Walkway >= 10 feet wide 370 ft2 0.11 Yes 41 Total Tradable Watts (a) = Total Allowed Watts = Total Allowed Supplemental Watts (b) = 41 41 500 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 500 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Walkway >= 10 feet wide (370 ft2): Tradable Wattage HH: Other:1 2 25 50 GGE: Other:1 2 43 86 136Total Tradable Proposed Watts = Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been designed to meet the 90.1 (2016) Standard requirements in COMcheck Version 4.1.2.2 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Exterior Lighting PASSES Project Title: Data filename: Customer Laundry Addition M:\03\03-19-11467 Loves - Fort Pierce, FL 467\DESIGN\comcheck\comcheck.cck 09/11/20Report date: 62 ofPage Inspection Checklist Requirements: 100.0% were addressed directly in the COMcheck software COMcheck Software Version 4.1.2.2 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 90.1 (2016) Standard Section # & Req.ID Plan Review Complies?Comments/Assumptions 4.2.2, 8.4.1.1, 8.4.1.2, 8.7 [PR6]2 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the electrical systems and equipment and document where exceptions are claimed. Feeder connectors sized in accordance with approved plans and branch circuits sized for maximum drop of 3%. Complies Does Not Not Observable Not Applicable Requirement will be met. 4.2.2, 9.4.3, 9.7 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.7 [PR8]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the exterior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Customer Laundry Addition M:\03\03-19-11467 Loves - Fort Pierce, FL 467\DESIGN\comcheck\comcheck.cck 09/11/20Report date: 63 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions 8.4.2 [EL10]2 At least 50% of all 125 volt 15- and 20-Amp receptacles are controlled by an automatic control device. Complies Does Not Not Observable Not Applicable Exception: Space type is not private office, open office, or computer classroom. 8.4.3 [EL11]2 New buildings have electrical energy use measurement devices installed. Where tenant spaces exist, each tenant is monitored separately. In buildings with a digital control system the energy use is transmitted to to control system and displayed graphically. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 9.4.1.1 [EL1]2 Automatic control requirements prescribed in Table 9.6.1, for the appropriate space type, are installed. Mandatory lighting controls (labeled as 'REQ') and optional choice controls (labeled as 'ADD1' and 'ADD2') are implemented. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.1.1 [EL2]2 Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.1.1f [EL13]1 Daylight areas under skylights and roof monitors that have more than 150 W combined input power for general lighting are controlled by photocontrols. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 9.4.1.4 [EL3]2 Automatic lighting controls for exterior lighting installed. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.1.3 [EL4]1 Separate lighting control devices for specific uses installed per approved lighting plans. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.6.2 [EL8]1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Customer Laundry Addition M:\03\03-19-11467 Loves - Fort Pierce, FL 467\DESIGN\comcheck\comcheck.cck 09/11/20Report date: 64 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions 8.7.1 [FI16]3 Furnished as-built drawings for electric power systems within 30 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. 8.7.2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.2.2.3 [FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. 9.4.2 [FI19]1 Exterior lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Exterior Lighting fixture schedule for values. 9.4.4 [FI20]1 At least 75% of all permanently installed lighting fixtures in dwelling units have >= 55 lm/W efficacy or a >= 45 lm/W total luminaire efficacy. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Customer Laundry Addition M:\03\03-19-11467 Loves - Fort Pierce, FL 467\DESIGN\comcheck\comcheck.cck 09/11/20Report date: 65 ofPage Project Title: Data filename: Customer Laundry Addition M:\03\03-19-11467 Loves - Fort Pierce, FL 467\DESIGN\comcheck\comcheck.cck 09/11/20Report date: 66 ofPage