HomeMy WebLinkAboutEnergy Code`
~
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
r,
°w`°po�''`
'
�
Section 9 Compliance Program ~^ Residential Point System Method
Version 1"0 Januaryv 1992
Department Of Community Affairs
�Printout generated by EP192 and submitted in lieu of Form 900-A-91
THIS COMPLIANCE FORM IS VALID IF SUBMITTED AFTER JANUARY 1, 1992
-_~----_--_-~~__---~--_----~.----__----~--___-__~~-------~---~.--~--~_____~------
PRQJECT NAME: ! PERMITTING OFFICE:
------------------------------ /
AND ADDRESS: ^ � | --------------------------------
I CLIMATE ZONE: 4 5 6
---------~^~^-~------+------^-~-- | --------------
BUILDER: A & P CONSTRUCTION | PERMIT NO..
� ------------------------------ | --------------
OWNER; H8LTZMAN | JURISDICTION NU.;
~---~-------~--~~^-~-~---------~^ | -~--~~^~-~---^~-
C8MPO�ENT:
DIMENSION:
STRUCTURE TYPE:
PREDOMINANT EVE OVERHANG
Length:
p0RC40VERHANG
Length:
WINDOWS
Single Tint
Total Area
All Vertical Glas0
'Total Area
�All Skylight Glass
Total Area
WALLS .
ExtWood Frame
Area:
DOORS
ExtInsulated
Area -
CEILINGS
FLAT Under Attic
Area:
FLOORS
VALUE: RATING: VALUE: OFFICIAL CHECKLIST
3"0@
°~°
179"8,N
179,L40
,@0
1546"00 R-Val:
20.40
2320.00 R~^Val:
�
�
19°00_~~~~~~�~�
Slab^~on-Grade Perimeteri 194°00 R-Val: "00
DUCTS
�Unconditioned Space Length ALL R~Val: 6"00
COOLING
Central A/C SEER: 10"00
Multizone: Credit
HEHTING
Strip Heat STRIP: 1"00
Multizmme: Credit
�
INFILTRATION
Ir RATIQM
Conditioned
Floor
AS BUILT POIN_
n/S
m
30,868°�
,1
�
Bedrooms:
Area: 2320°00 Pr@ct.
~~~~--~~---
BASE POINTS 100 EPI
33,669"@1
91.68
GLASS TO FLOOR AREA RATIO = .0772
I Hereby certify that the plans and 1 Review of the plans and specifications
specifications covered by this calcu— 1 covered by this calculation indicates
lation are in compliance with the I compliance with the Florida Energy
Florida Energy Code. 0Tf"B cll�td
1-k his building will be inspected for
f2EPRRED BY I coMpliance in accordance with Section
I 553.908 F.S.
I
I hereby certify that this building is I
in compliance with the Florida Energy I
Code.
OWNER/AGENT: _ I BUILDING OFFICIAL: ___.
DATE:' — I DATE:__
SUMMER CALCULATIONS
BASE __= I =_= AS -BUILT
a.aaaxxxxaxxaaaaYsaasxaxxxxxxxaaaaxaaaax=xaxxxaaasaaaxxxxxaxxaaaaaaaaxxxxxxxxaxa
GLASS---------------- I
ORIEN AREA x BSPM = POINTS I TYPE SC ORIEN AREA x SPM x SOF POINTS
N
81.00
47.8
3871.8
1 SGL
TINT
N
21.0
51.5
.82
881.9
1 SGL
TINT
N
12.0
51.5
.78
461.5
1 SGL
TINT
N
12.0
51.5
.78
481.5
1
SGL
TINT
N
12.0
51.5
.78
481.5
1 SGL
TINT
N
12.0
51.5
.78
461.5
1
SGL
TINT
N
12.0
51.5
.78
481.5
E
22.00
102.0
2244.0
1 SGL
TINT
E
11.0
107.1
.52
612.6
1
SGL
TINT
E
11.0
107.1
.52
612.6
S
54.00
90.9
4908.6
1 SGL
TINT
S
34.0
98.3
.63
2117.7
1
SGL
TINT
S
9.0
98.3
.43
381.8
1
SGL
TINT
S
11.0
98.3
.39
421.7
W
22.00
102.0
2244.0 1
SGL
TINT
W
11.0
107.1
.52
612.6
1
SGL
'TINT
W
11.0
107.1
.52
612.6
.15
x;COND. FLUOR /
TOTAL GLASS =
ADJ. x
GLASS'
- ------------------------
- ADJ
GLASS
1
GLASS
AREA
AREA
FACTOR
POINTS
POINTS
I
POINTS
.15 2,320.00 179.00 1.944 13, 268. 40 25, 795. 55 1 8,660.96
__=====aasassssmw.-----------------------------------------------------'
NON GLASS-------W-__-_
AREA x 88PM = POINTS 1
TYPE R-VALUE AREA
x SPM = POINTS
------------------------------
'
WALLS -----------a-----
Ext 1546.0 i.LA 1546.0 1
Ext Wood Frame 11.0 1546.0
1.90 2937.4
DOORS---------------- I
Ext 20.4 4.8 97.9 1
Ext Insulated 20.4
4.80 97.9
i
CEILINGS --------=----
UA 2320.0 .6 1392.0 1
Under Attic 19.0 2320.0
1.10 2552.0
FLOORS ----------_ ----
S1b 194.0 -31.8-6169.2 1
Slab -on -Grade .0 194.0
-31.90-6188.6
1
INFILTRATION---------
2320.0 10.9 25288.0 I
Practice #2 2320.0
10.90 25288.0
TOTAL SUMMER POINTS I
47,950.27 1
33 347.70
TUTAL
SUM Pry ..p07N
x Cf x SYSTEM x CREDIT = COOLING
Ct+#fD
--------------- i
-------------------�
�- MIILi
MOLT POINTS
4'7, 9�0 27 3 17, 741. 60 1
-D
--------- -----------------------
33, 347. 70 1.00 1. 100 .340
.900 11 224. 84
"�-"�-"_ - _ _ xa -. -._ r. xxaaxxaaa aCxaaaxaaaxaaax
iF�ETF#T4iE•BFit#�tatit�r�r�r�-***********#itit-a��t�tat�tjtit*at*at�r****�**********jt�r****it�t****��*�*stir**xi
WINTER CALCULATIONS
BASE ___ I =_= AS -BUILT
--------------------------------------------------------------- =---aaam
GLASS.----------------
rini,Ftu ouco Auom =
SC ORIEN AREA .se BPM x WOF POINTS
N
81.00
5.6
453.6
I SOL
TINT
N
21.0
4.6
I
SOL
TINT
N
12.0
9.6
1.14
130.8
1 SOL
TINT
N
12.0
9.6
1.14
130.8
1
SOL
TINT
N
12.0
9.6
1.14
130.8
1 SOL
TINT
N
12.0
9.6
1.14
130.8
I SOL
TINT
N
12.0
9.6
1.14
130.8
E
22.00
-5.6
-123.2
1 SOL
TINT',,
E
11.0
-2.0
-2.03
44.7
1 SOL
TINT
E
11.0
-2.0
-2.03
44.7
S
54.00
-14.0
-756.0
1 SOL
TINT'
S
34.0
-10.2
.64
-222.6
1 SOL
TINT
S
9.0
-10.2
.05
-4.6
1 SOL
TINT
S
11.0
-10.2
-.13
14.6
W
22.00
-5.6
-123. 2
1 SOL
TINT
W
11.0
-2.0
-2.03
44.1
1 SOL
TINT
W
11.0
-2.0
-2.03
44.7
-------------------------------------------------------------------------------
.15
x COND. FLOOR /
TOTAL GLASS = ADJ. 'x
GLASS
= ADJ
GLASS
I
GLASS
AREA
AREA
FACTOR',
POINTS
POINTS
I
POINTS
.15 21320.00 179.00 1.944,-548.80-11066.94 1 844.03
NON GLASS------------ I
AREA x BWPM = POINTS I TYPE R-VALUE AREA x WPM = POINTS
WALLS ----------------
Ext 1546.0 1.1 1700.6 1 Ext Wood ',Frame 11.0 1546.0 2.00 3092.0
DOORS ----------------
Ext 20.4 5.1 104.0
1 Ext Insulated
20.4
5.10
104.0
CEILINGS-------------
1
UA 2320.0 .6 1392.0
1 Under Attic
19.0 2320.0
1.00
2320.0
FLOORS--------------
1
I
Slb 194.0 -1.9 -368.6
1 Slab -on -grade
.0 194.0
2.50
485.0
INFILTRATION---•------
1
I
2320.0 4.1 9512.0
1 Practice #2
2320.0
4.10
9512.0
TOTAL WINTER POINTS
i
11, 273. 10
1
16, 357. 0`7
TOTAL x SYSTEM = HEATING
I TOTAL x CAP x
DUCT x SYSTEM x
CREDIT
= HEATING
WIN'PTS MULT POINTS
I COMPON RATIO
MULT MULT
MULT
POINTS
119273.10 1.10 121400.41 116,357.07 1.00 1.100 1.000 .900 16,193.516
WATER HEATING
RASE __= I _-= AS -BUILT
NUM OF x MULT = TOTAL I TANK VOLUME EF TANK x MULT x CREDIT = TOTAL
REDRMS 1 IRATIO MULT
1 3527.0 3,527.00 1 40
---------------------------
. 90 1.000 3449.7 1.00 3, 449. 6.7
------------------------
SUMMARY
BASE __= I __= AS -BUILT
COOLING HEATING HOT WATER TOTAL I COOLING HEATING HOT WATER TOTAL
POINTS + POINTS + POINTS = POINTS I POINTS + POINTS + POINTS = POINTS
----------------
17741. 6 12400.4 3527.0 33, 669. 01 1 11224.8 16193.5 3449.7 30, 868. 01
#################
# EPI = 91.66 #
-I'qIND'O'W ANALYSIS
CRIRMTXN
CC=
C[,
ATIA
EUIMN
lqqES
I;um
V
1p
3
w
aore"num,
DOOR ANALYSIS
SIZE AIM
X6 .5
BUILDING ANALYSIS
ADD
u