Loading...
HomeMy WebLinkAboutEnergy Code` ~ FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION r, °w`°po�''` ' � Section 9 Compliance Program ~^ Residential Point System Method Version 1"0 Januaryv 1992 Department Of Community Affairs �Printout generated by EP192 and submitted in lieu of Form 900-A-91 THIS COMPLIANCE FORM IS VALID IF SUBMITTED AFTER JANUARY 1, 1992 -_~----_--_-~~__---~--_----~.----__----~--___-__~~-------~---~.--~--~_____~------ PRQJECT NAME: ! PERMITTING OFFICE: ------------------------------ / AND ADDRESS: ^ � | -------------------------------- I CLIMATE ZONE: 4 5 6 ---------~^~^-~------+------^-~-- | -------------- BUILDER: A & P CONSTRUCTION | PERMIT NO.. � ------------------------------ | -------------- OWNER; H8LTZMAN | JURISDICTION NU.; ~---~-------~--~~^-~-~---------~^ | -~--~~^~-~---^~- C8MPO�ENT: DIMENSION: STRUCTURE TYPE: PREDOMINANT EVE OVERHANG Length: p0RC40VERHANG Length: WINDOWS Single Tint Total Area All Vertical Glas0 'Total Area �All Skylight Glass Total Area WALLS . ExtWood Frame Area: DOORS ExtInsulated Area - CEILINGS FLAT Under Attic Area: FLOORS VALUE: RATING: VALUE: OFFICIAL CHECKLIST 3"0@ °~° 179"8,N 179,L40 ,@0 1546"00 R-Val: 20.40 2320.00 R~^Val: � � 19°00_~~~~~~�~� Slab^~on-Grade Perimeteri 194°00 R-Val: "00 DUCTS �Unconditioned Space Length ALL R~Val: 6"00 COOLING Central A/C SEER: 10"00 Multizone: Credit HEHTING Strip Heat STRIP: 1"00 Multizmme: Credit � INFILTRATION Ir RATIQM Conditioned Floor AS BUILT POIN_ n/S m 30,868°� ,1 � Bedrooms: Area: 2320°00 Pr@ct. ~~~~--~~--- BASE POINTS 100 EPI 33,669"@1 91.68 GLASS TO FLOOR AREA RATIO = .0772 I Hereby certify that the plans and 1 Review of the plans and specifications specifications covered by this calcu— 1 covered by this calculation indicates lation are in compliance with the I compliance with the Florida Energy Florida Energy Code. 0Tf"B cll�td 1-k his building will be inspected for f2EPRRED BY I coMpliance in accordance with Section I 553.908 F.S. I I hereby certify that this building is I in compliance with the Florida Energy I Code. OWNER/AGENT: _ I BUILDING OFFICIAL: ___. DATE:' — I DATE:__ SUMMER CALCULATIONS BASE __= I =_= AS -BUILT a.aaaxxxxaxxaaaaYsaasxaxxxxxxxaaaaxaaaax=xaxxxaaasaaaxxxxxaxxaaaaaaaaxxxxxxxxaxa GLASS---------------- I ORIEN AREA x BSPM = POINTS I TYPE SC ORIEN AREA x SPM x SOF POINTS N 81.00 47.8 3871.8 1 SGL TINT N 21.0 51.5 .82 881.9 1 SGL TINT N 12.0 51.5 .78 461.5 1 SGL TINT N 12.0 51.5 .78 481.5 1 SGL TINT N 12.0 51.5 .78 481.5 1 SGL TINT N 12.0 51.5 .78 461.5 1 SGL TINT N 12.0 51.5 .78 481.5 E 22.00 102.0 2244.0 1 SGL TINT E 11.0 107.1 .52 612.6 1 SGL TINT E 11.0 107.1 .52 612.6 S 54.00 90.9 4908.6 1 SGL TINT S 34.0 98.3 .63 2117.7 1 SGL TINT S 9.0 98.3 .43 381.8 1 SGL TINT S 11.0 98.3 .39 421.7 W 22.00 102.0 2244.0 1 SGL TINT W 11.0 107.1 .52 612.6 1 SGL 'TINT W 11.0 107.1 .52 612.6 .15 x;COND. FLUOR / TOTAL GLASS = ADJ. x GLASS' - ------------------------ - ADJ GLASS 1 GLASS AREA AREA FACTOR POINTS POINTS I POINTS .15 2,320.00 179.00 1.944 13, 268. 40 25, 795. 55 1 8,660.96 __=====aasassssmw.-----------------------------------------------------' NON GLASS-------W-__-_ AREA x 88PM = POINTS 1 TYPE R-VALUE AREA x SPM = POINTS ------------------------------ ' WALLS -----------a----- Ext 1546.0 i.LA 1546.0 1 Ext Wood Frame 11.0 1546.0 1.90 2937.4 DOORS---------------- I Ext 20.4 4.8 97.9 1 Ext Insulated 20.4 4.80 97.9 i CEILINGS --------=---- UA 2320.0 .6 1392.0 1 Under Attic 19.0 2320.0 1.10 2552.0 FLOORS ----------_ ---- S1b 194.0 -31.8-6169.2 1 Slab -on -Grade .0 194.0 -31.90-6188.6 1 INFILTRATION--------- 2320.0 10.9 25288.0 I Practice #2 2320.0 10.90 25288.0 TOTAL SUMMER POINTS I 47,950.27 1 33 347.70 TUTAL SUM Pry ..p07N x Cf x SYSTEM x CREDIT = COOLING Ct+#fD --------------- i -------------------� �- MIILi MOLT POINTS 4'7, 9�0 27 3 17, 741. 60 1 -D --------- ----------------------- 33, 347. 70 1.00 1. 100 .340 .900 11 224. 84 "�-"�-"_ - _ _ xa -. -._ r. xxaaxxaaa aCxaaaxaaaxaaax iF�ETF#T4iE•BFit#�tatit�r�r�r�-***********#itit-a��t�tat�tjtit*at*at�r****�**********jt�r****it�t****��*�*stir**xi WINTER CALCULATIONS BASE ___ I =_= AS -BUILT --------------------------------------------------------------- =---aaam GLASS.---------------- rini,Ftu ouco Auom = SC ORIEN AREA .se BPM x WOF POINTS N 81.00 5.6 453.6 I SOL TINT N 21.0 4.6 I SOL TINT N 12.0 9.6 1.14 130.8 1 SOL TINT N 12.0 9.6 1.14 130.8 1 SOL TINT N 12.0 9.6 1.14 130.8 1 SOL TINT N 12.0 9.6 1.14 130.8 I SOL TINT N 12.0 9.6 1.14 130.8 E 22.00 -5.6 -123.2 1 SOL TINT',, E 11.0 -2.0 -2.03 44.7 1 SOL TINT E 11.0 -2.0 -2.03 44.7 S 54.00 -14.0 -756.0 1 SOL TINT' S 34.0 -10.2 .64 -222.6 1 SOL TINT S 9.0 -10.2 .05 -4.6 1 SOL TINT S 11.0 -10.2 -.13 14.6 W 22.00 -5.6 -123. 2 1 SOL TINT W 11.0 -2.0 -2.03 44.1 1 SOL TINT W 11.0 -2.0 -2.03 44.7 ------------------------------------------------------------------------------- .15 x COND. FLOOR / TOTAL GLASS = ADJ. 'x GLASS = ADJ GLASS I GLASS AREA AREA FACTOR', POINTS POINTS I POINTS .15 21320.00 179.00 1.944,-548.80-11066.94 1 844.03 NON GLASS------------ I AREA x BWPM = POINTS I TYPE R-VALUE AREA x WPM = POINTS WALLS ---------------- Ext 1546.0 1.1 1700.6 1 Ext Wood ',Frame 11.0 1546.0 2.00 3092.0 DOORS ---------------- Ext 20.4 5.1 104.0 1 Ext Insulated 20.4 5.10 104.0 CEILINGS------------- 1 UA 2320.0 .6 1392.0 1 Under Attic 19.0 2320.0 1.00 2320.0 FLOORS-------------- 1 I Slb 194.0 -1.9 -368.6 1 Slab -on -grade .0 194.0 2.50 485.0 INFILTRATION---•------ 1 I 2320.0 4.1 9512.0 1 Practice #2 2320.0 4.10 9512.0 TOTAL WINTER POINTS i 11, 273. 10 1 16, 357. 0`7 TOTAL x SYSTEM = HEATING I TOTAL x CAP x DUCT x SYSTEM x CREDIT = HEATING WIN'PTS MULT POINTS I COMPON RATIO MULT MULT MULT POINTS 119273.10 1.10 121400.41 116,357.07 1.00 1.100 1.000 .900 16,193.516 WATER HEATING RASE __= I _-= AS -BUILT NUM OF x MULT = TOTAL I TANK VOLUME EF TANK x MULT x CREDIT = TOTAL REDRMS 1 IRATIO MULT 1 3527.0 3,527.00 1 40 --------------------------- . 90 1.000 3449.7 1.00 3, 449. 6.7 ------------------------ SUMMARY BASE __= I __= AS -BUILT COOLING HEATING HOT WATER TOTAL I COOLING HEATING HOT WATER TOTAL POINTS + POINTS + POINTS = POINTS I POINTS + POINTS + POINTS = POINTS ---------------- 17741. 6 12400.4 3527.0 33, 669. 01 1 11224.8 16193.5 3449.7 30, 868. 01 ################# # EPI = 91.66 # -I'qIND'O'W ANALYSIS CRIRMTXN CC= C[, ATIA EUIMN lqqES I;um V 1p 3 w aore"num, DOOR ANALYSIS SIZE AIM X6 .5 BUILDING ANALYSIS ADD u