GENERAL NOTES:
1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION
2. THE DESIGN & CONSTRUCTION OF THIS STRUCTURE MUST FULLY COMPLY WITH THE 2017 FLORIDA
BUILDING CODE-R (6TH EDITION), LATEST EDITIONS OF ACI 318, NCMA, NATIONAL FOREST
PRODUCT ASSOC., NDS, TPI, AND ANY OTHER NATIONALLY RECOGNIZED ORGANIZATIONS THAT
GOVERN THIS BODY OF WORK.
3. ALL WORK SHALL COMPLY WITH ALL' LOCAL AND REGIONAL ORDINANCES.
DESIGN PARAMETERS FOR WIND LOAD COMPLIANCE
1. RISK CATEGORY: II
2. CODE REFERENCE: 2017 FLORIDA BUILDING CODE-R (6TH EDITION) & ASCE 7-10
2017 EXISTING FLORIDA BUILDING CODE-R (6TH EDITION)
3. BUILDING DESIGN: ENCLOSED
4. MEAN ROOF HEIGHT: <-16
5. GCpl: t 0.18
6. WIDTHOFENDZONE: A=4.0
7. WIND SPEED: 160 MPH (Vult) 3-SECOND GUST
124 MPH (Vasd) 3-SECOND GUST
8. WIND EXPOSURE: C
9. ADJUSTMENT FACTOR: 1.21
10. SHEAR WALLS WERE CONSIDERED
11. A CONTINUOUS LOAD PATH WAS PROVIDED
TIMBER NOTES:
1. EXTERIOR FRAME WALL SHEATHING TO BE MIN.12- APA SHEATHING, SPECIES GROUP 1, SPAN
RATING OF 2410 OR BETTER. UNLESS OTHERWISE NOTED, INSTALL WITH FACE GRAIN HORIZONTAL.
PLYWOOD SHALL BE 4 PLY MINIMUM. NAIL TO STUDS USING 8d NAILS @ 6- O.C. AT PANEL EDGES
AND 10' O.C. IN THE FIELD. DECREASE SPACING PER PLAN. AT SHEAR WALLS, NAIL TO EACH STUD
AT THE END OF THE WALLS FOLLOWING THE EDGE SPACING. BACK OUT AND REMOVE ALL NAILS
THAT DO NOT FULLY PENETRATE/MISS FRAMING MEMBERS..
2. THE MINIMUM LUMBER GRADES SHALL BE AS SUCH:
2.1. INT. & ENT. BEARING WALLS, TOP PLATES, WINDOW BUCKS, & HEADERS:
2.1.1. SOUTHERN YELLOW PINE H2 OR BETTER
2.2. BOTTOM PLATES AGAINST CONCRETE:
2.2.1. PRESSURE TREATED SOUTHERN YELLOW PINE 420R BETTER
3. ALL TIMBER IN CONTACT WITH MASONRYOR CONCRETE SHALL BE PRESSURE TREATED OR HAVE
AN APPROVED SEPARATING MATERIAL.
4. ALL NAILS AND METAL HARDWARE EXPOSED TO THE ELEMENTS SHALL BE GALVANIZED. ALL NAILS
SHALL BE COMMON WIRE NAILS. SPACE NAILS AT STRAPS AS TO NOT SPLIT THE WOOD.
JAMES HARDIE - PLANK SIDING, PER
FLORIDA PRODUCT APPROVAL
(FL- 13192) ATTACHED W/ 2 112" LONG,
0.223" HEAD DIA., 0.092 SHANK DIA.
NAIL. 8 1/4" O.C. VERT. & 16" O.C. HORIZ.
2X WOOD STUD WALL 16" O.C.
W/T-1-11 SHEATHING W/ 8d
NAILS @ 6" O.C. AT THE EDGES
& 10" O.C. IN THE FIELD
IF REPLACEMENT SHEATHING
IS NEEDED REPLACE W 2' X 4'
SECTION OF 1/2" MIN. CDX
SHEATHING W/ 8d NAILS @ 6"
O.C. AT THE EDGES & 10" O.C.
IN THE FIELD
HARDIE PLANK SIDING REPAIR DETAIL
SCALE: 3/4" = T-0"
JJSEAL • •� � �
a U)
o �3
0
LL
U
Cw �
a
jo w ��
0
LL
c=
Nz
w w
tLU
z `1
gcMd
°o w
w
ca p
Z� =�g
PROD. NO. 20-2500
DATE 08262020
SHEET NO.
S-1
SHEET ) OF