Loading...
HomeMy WebLinkAboutOwens Corning Shingle_HighlightedNEMO I etc. Certificate of Authorization ##32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY IIIIATION RFPOF Owens Corning Evaluation Report 037940.02.12-R10 One Owens Corning Parkway FL10674-1115 Toledo, OH 43659 Date of Issuance: 02/06/2012 (740) 404-7829 Revision 10: 08/15/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMC) I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: 4titLtltp„ "` ,.���„,,.rw^'""° ,,,..,rte°""'«. �tya S?•:� s #�y.. The facsimile seal appearing was authorized by Robert Robert J.M. Nieminen, P.E. F ..; :.. Nieminen, P.E. on 08/15/2019. This does not serve as an Florida Registration No. 59166, Florida DCA ANE1983 " „-'��zt..r i� +"' electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO Ietc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO I etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEW I etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02018, NEMC) ETC, LLC IMNEMO I etc. ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 6t' Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Property Standard Year 1507.2.4, R905.2.3 Physical Properties ASTM D1970 2015 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2011 Ent! Examination Reference Date Owens Corning Declaration Equivalency Declaration 08/06/2019 PRI(TST5878) ASTM D1970 OCF-382-02-01 10/24/2017 UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TST9628) Physical Properties Classification letter 10/02/2015 Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs Various PRI (QUA9110) Quality Control Service Confirmation 04/05/2020 4.1 ACCESSORY STARTERS: 4.1.1 Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter are starter strips for asphalt roof shingles. Meets ASTM D3462. 4.1.2 Starter Shingle ROTI is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen starter strip, nominal 7.2 -inch wide x 33 -ft 4 -inch long roll, for use with asphalt shingles. Meets ASTM D1970. 4.2 ASPHALT SHINGLES: 4.2.1 Classic® and Supreme' are fiberglass reinforced, 3 -tab asphalt roof shingles. Meets ASTM D3462 4.2.2 Berkshire' are fiberglass reinforced, 4 -tab asphalt roof shingles. Meets ASTM D3462. 4.2.3 Duration', TruDefinition Duration, Duration' Premium Cool, Tru Definition Duration' Designer Color Collection, Tru Definition Oakridge', Oakridge and WeatherGuards HP are fiberglass reinforced, laminated asphalt roof shingles. Meets ASTM D3462. 4.3 HIP & RIDGE SHINGLES: 4.3.1 Berkshire" Hip & Ridge Shingles with Sealant, DuraRidge® Hip & Ridge Shingles with Sealant, ProEdge° Hip & Ridge Shingles and WeatherGuard' HP Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. Meets ASTM D3462. NEMO ETC, LLC Evaluation Report 037940.02.12-R10 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-RIS Owens Corning Asphalt Roof Shingles Revision 30: 08/15/2019 Page 2 of 10 NEMO I etc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 The Owens Corning asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating acceptable use in all wind zones Up to Vasd = 150 mph (V„it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Note: Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.2 Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter noted in Section 4.1.1 and the Owens Corning hip & ridge shingles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating acceptable use in all wind zones up to Vasd = 150 mph (V,it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. INSTALLATION:6. 6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 611320-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and published installation instructions. 6.2 ACCESSORY STARTERS: 6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens Corning current published instructions, using minimum five (5) nails per strip. Felt w.deriepmet” ...._. Deck SWA"ed wva4twriow " umd.isYmeat Drip,_ Drip ad" adw - Nib boated r -J` from errs kttt fhsf S444081atp akeastve Stena Strip , -'' positioned abmp save slrinph with .... _....__....s,. ,. E" osmosed Start. Strip sh$tpie -whimp .oras and ekes Z-`,." Figure 1: Minimum Nailing, Starter Strip Figure 2: Minimum Nailing, btarter zrip rius Evaluation Report 037940.02.12-1110 NEMO ETC, LLC Certificate of Authorization #32455 6T" EDITION (2017) FSC NON-HVHZ EVALUATION F1.10674-1115 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 3 of 10 IMMEMO I etc. 6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions. Drip Deck 6.3 ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: y Berkshire' shingles require minimum five (5) nails per shingle. WeatherGuard` HP shingles require minimum six (6) nails per shingle. Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required Refer to Owens Corning published information on wind resistance and installation limitations. 6.3.1.1 Classic® & Supreme: Normal Mansard or Area pare Wind Areas High Wind deavanes y Area para vientos normales Areas vientos fuertes t' tai rt" 2" (B r2' tt• �r,. 5" Exposure Exposici6n Figure 4: Minimum Nailing, Classic & Supreme (Standard Size) Normal Mansard or Area para Wind Areas High Wind daavenes y Area pare vientos normales Areas vientos /uertas 12 r1. 2., _(el r2. V i • 5 5/8" Exposure Exposici6n Figure 5: Minimum Nailing, Classic & Supreme (Metric Size) NEMO ETC, LLC Evaluation Report 037940.02.12-1110 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F110674-1115 Owens Corning Asphalt Roof Shingles Revision 30: 08/15/2019 Page 4 of 10 Underlayment Drip edge fE i� y ✓9Y' E de s Starter Shingle Rolf adhered directly to underlayment and y primed drip edge Self-sealing adhesive positioned along eaves Figure 3: Starter Shingle Roll 6.3 ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: y Berkshire' shingles require minimum five (5) nails per shingle. WeatherGuard` HP shingles require minimum six (6) nails per shingle. Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required Refer to Owens Corning published information on wind resistance and installation limitations. 6.3.1.1 Classic® & Supreme: Normal Mansard or Area pare Wind Areas High Wind deavanes y Area para vientos normales Areas vientos fuertes t' tai rt" 2" (B r2' tt• �r,. 5" Exposure Exposici6n Figure 4: Minimum Nailing, Classic & Supreme (Standard Size) Normal Mansard or Area para Wind Areas High Wind daavenes y Area pare vientos normales Areas vientos /uertas 12 r1. 2., _(el r2. V i • 5 5/8" Exposure Exposici6n Figure 5: Minimum Nailing, Classic & Supreme (Metric Size) NEMO ETC, LLC Evaluation Report 037940.02.12-1110 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F110674-1115 Owens Corning Asphalt Roof Shingles Revision 30: 08/15/2019 Page 4 of 10 6.3.1.2 Berkshire®: Sealant strip La all da seNadm Figure 6: 5 -Nail Pattern, Berkshire ONEMOjetc. Figure 7: 6 -Nail Pattern, Berkshire Figure 8: Mansard or Steep Slope Pattern, Berkshire Evaluation Report 037940.02.12-1110 NEMO ETC, LLC F1.10674-1315Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 5 of 10 AAL IV) MEMO j etc. 6.3.1.3 Duration® TruDefinition® Duration Duration® Premium Cool & TruDefinition® Duration® Designer Color Collection: 4 -Nail Fastening Pattern sureNaim fastening arra width Nail, Typical 1^, 17, 12" 1" cen sweet i.:' 6-118" 5-518^' Figure 9: Standard 4 -Nail Pattern, Duration Figure 10: 6 -Nail Pattern, Duration Fastening for Slopes Greater Than 21:12 SureflaiW fastening area width Nail, Typical 1., 12,^ 12" �syy!7ah F,cW+ii�9tfrtttir�'.. ! iw �4 gtNaua +*�. __ S�at�rtnE.p &zsrlva� _�;" 6-118" 5-518" eRpos,aa . �2•' Four 1^' Spots of Asphalt Roofing Cement Figure 11: Mansard or Steep Slope Pattern, Duration NEMO ETC, LLC Evaluation Report 037940.02.12-R10 Certificate of Authorization #31455 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R1S Owens Corning Asphalt Roof Shingles Revision 30: 08/15/2019 Page 6 of 10 6.3.1.4 Tru Definition' Oakridge® Oakridge®: 4 Nail Pattern Esquema corn 4 clauos ONEMOjetc. 5 519" Exposure Nails Exposition de 5 5/8 pufg ciavos D Deo cxpv,. o Exposition de 5 5/8 pufg. Figure 12: Standard 4 -Nail Pattern, Oakridge 6 Nail Pattern Esquema con 6 clavus 55/8" Exposure Fx;imid6n de 5 5/8 pufg. Moms t+blu txposule Exposition de 55/8 pufg. Figure 13: 6 -Nail Pattern, Oakridge Fastening for Slopes Greater Than 21:12 sumNaiKw fastening area width Nail Typical 12 8-118" 5518' Four 1" Spots of Asphalt Roofing Cement Figure 14: Mansard or Steep -Slope Pattern, Oakridge NEMO ETC, LLC Evaluation Report 037940.02.12-1110 Certificate of Authorizotion #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 30: 08/15/2019 Page 7 of 10 6.3.1.5 WeatherGuard® HP: 5 5ra' E sua Figure 15: 6 -Nail Pattern, WeatherGuard HP 6Mail Petty it 6 8" from bottom Estuerre con 6 clavos of Nail 6 11tte Clave a 6118 tj, de to 5 5T Expnre 6 Fastw ws parte inferior to Is tqa Exposici&n do 5 51109. 6 sa etadores Ftp t" Spots of Ault Rasf C,ernent Guano p altos da Ca rta da tadw de asfatto do 7 ptg#sda Figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HP A&I IMNEMO j etc. 6.4 HIP & RIDGE SHINGLES: 6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions. r Berkshire' Hip and Ridge Shingles with Sealant and Dura Ridge° Hip & Ridge Shingles with Sealant require minimum two (2) nails per shingle. r WeatherGuard HP Hip and Ridge Shingles and ProEdge° Hip & Ridge Shingles require minimum four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations. NEMO ETC, LLC Evaluation Report 037940.02.12-1110 Certificate of Authorization #32455 6'" EDITION (2017) FBC NON-HVH2 EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 8 of 10 6.4.1.1 nt4 NEMO ( etc. Berkshire® Hip & Ridge with Sealant and DuraRidge® Hip & Ridge Shingles with Sealant: Fig. A Prevailing Wind Direction f— Direccion del viento predorninante Figure 17: Isometric View, Berkshire and uuraKlage 6.4.1.2 WeatherGuard® HP Hip & Ridge Shingles: Fig. A 9 q Prevailing Wind r -- Direction_ A A Nails t E f k E>�$ur Figure 19: Isometric View, WeatherGuard HN Hip & Klage Fig. B Tap View Vista superior Nail Clava g +�iiYt( ! QrINlRS CD►RIrY41 `tatl' I I yI v 41i d ul I I Evaluation Report 037940.02.12-1110 NEMO ETC, LLC FL10674-RI5 Certificate of Authorization #32455 6?" EDITION (2017) FBC NON-HVHZ EVALUATION `tatl' I I yI v 41i d ul I I Figure 18: Plan View, Berkshire and uuraKlage Fig. C Hip & Ridge Shingle Fastening Top U Iewi Pails Nails t„ V. Exposure Figure 20: Plan View, WeatherGuard HP Hip & Ridge Owens Corning Asphalt Roof Shingles Revision 30: 08/15/2019 Page 9 of 10 6.4.1.3 ProEdge® Hip & Ridge Shingles: Prevailing Wind Direetion Suhnt 5" Expaw e Fasten 7'/r"' Cover Expa"d Fasteners with Roof Cafrasnt Figure 21: Isometric View, ProEdge ONEMO I etc. Standard rt1"---► F"taning Pattern '�1 (" 4 �!"� �_r t2* 1 — Saalatt ��• (,i`� EJipIIlllf[t Figure 22: Plan View, ProEdge 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. As required by the Building Official or Authority Having jurisdiction in order to properly evaluate the installation of this product. Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA requirements. PRI Construction Materials Technologies, LLC— QUA9110 ; 1513 1621-5777; bwilson@pricmt.com - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 037940.02.12-1130 Certificate of Authorization #32455 6"EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-1115 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 10 of 10