Loading...
HomeMy WebLinkAboutPool BackfillHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB # :204448-1pd/CF/jo CONTRACTOR:JM Custom Pools PERMIT #:2006-0895 JOB LOCATION:3411 S. Indian River Drive NUC #234 Fort Pierce, Florida Nuc Model:MC-DR P.O. # : Nuc Serial #:MD60308234 ITEM TESTED :Pool Backfill Compaction TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE PERCENT COMPACTION 1 South 0'-1'45 103.1 106.0 97.3% 2 1'-2'50+-"95.0% + 3 2'-3'50+-"95.0% + 4 3'-4'50+-"95.0% + 5 Northwest 0'-1'45 102.4 106.0 96.6% 6 1'-2'50+."95.0% + 7 2'-3'50+-"95.0% + 8 3'-4'50+-"95.0% + 9 Northeast 0'-1'45 104.1 106.0 98.2% 10 1'-2'50+-"95.0% + 11 2'-3'50+-"95.0% + 12 3'-4'50+-"95.0% + Soil Description: Light Brown Sand In Place Moisture: 6.1% Proctor Optimum Moisture: 12.0% Proctor Max. Dry Density: P.C.F. 106.0 @ Test Locations the Density & Penetrometer reading indicate the Degree of Compaction Meets Minimum Requirement for Plumbed Backfill Respectfully Submitted: Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 9/14/2020 Email to: St Lucie Building Department; jmcustompoolsinc@gmail.com SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 September 11, 2020 Disclaimer:Contractor is responsible to maintain the pool backfill in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the poolbackfill has been altered from the approved inspected condition. Proudly Serving Florida since 1990 103.0 104.0 105.0 106.0 107.0 9 10 11 12 13 14 15 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight