Loading...
HomeMy WebLinkAbout204451-1d Compaction - signedHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net September 14, 2020 KSM JOB # :204451-1d/CH/jo CONTRACTOR:JTC Concrete Plus, LLC 280 Germany Canal Road Port St Lucie, Florida JOB LOCATION:13303 Orange Avenue Fort Pierce, Florida PERMIT #:SLC 2007-0652 To Whom it may concern, Should you have any question, please feel free to contact our office. Respectfully, Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 09/14/20 Email to: St Lucie Building Department; jtc.concrete.plus@aol.com Enclosed, please find the nuclear density test results performed on the garage pad at the above referenced project. Proudly Serving Florida since 1990 Headquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB # :204451-1d/CH/jo PERMIT #:SLC 2007-0652 NUC #417 CONTRACTOR:JTC Concrete Plus, LLC Nuc Model:3500 JOB LOCATION:13303 Orange Avenue Nuc Serial #:3417 Fort Pierce, Florida ITEM TESTED:Garage Pad TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F.) PERCENT COMPACTION 1. S.E.0" - 12"39 106.8 110.0 97.1% 2. Center "35 106.1 "96.5% 3. N.W."41 107.1 "97.4% 4. S.W."106.8 "97.1% 5. Center "106.8 "97.1% Soil Description: Brown Sand In Place Moisture: 13.8% Proctor Optimum Moisture: 12.0% Proctor Max. Dry Density: P.C.F. 110.0 @ Test Locations the Density & Penetrometer reading indicate the Degree of Compaction Meets Minimum Requirement for Unstaked Foundation Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 9/14/2020 Proudly Serving Florida since 1990 Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 September 11, 2020 Headquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB # :204451-1d/CH/jo PERMIT #:SLC 2007-0652 CONTRACTOR:JTC Concrete Plus, LLC JOB LOCATION:13303 Orange Avenue Fort Pierce, Florida Soil Description: Brown Sand Proctor Optimum Moisture: 12.0% Proctor Max. Dry Density: P.C.F. 110.0 Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 9/14/2020 SOIL COMPACTION REPORT ASTM D 1557 September 11, 2020 Proudly Serving Florida since 1990 105.0 106.0 107.0 108.0 109.0 110.0 111.0 7 8 9 10 11 12 13 14 15 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight