Loading...
HomeMy WebLinkAboutProduct Approval (2) File Cagy MIAMI-D.ADE COUNTY T D>.TcT CaNTRo1,SECTION DEPARTMENT'OF REGULATORY.AND ECO Oi6 WRESOURUs r '�� owl t 105 SW 26 Street,Room 208' i3()ARD A;E�Ti}(tlilE ADMINISTRATION d DINISi 4 �� �i��iT'���� f.ni; leri&6)315-21474 NOTICE OF ACCEPTANCE. 0A UN. miamidade. ov/ecp omv. Gulf coast Supply. `ll &Manufacturing,N C. r, 4020 SW 449`"Street BOCC W Horseshoe Beach;F.L.32648: SCOPE: This NOA is being:issued under the applic tble rules and regulations governing the use of construction materials. The documentation submittedhas been review dd and accepted by Miami-Dade County RER-Product Control Section to be used-in Miami Dade County ah&other are where allowed by Authority Having Jurisdiction(AHJ): This NOA shall not be valid after the expi' tion date stated below.The',Miami-Dade County Product Control Section (In,Miami Dade County)and/or the AHJ( `areas other than,Miami Dade County)reserve the right to,have this product or material tested for quality assurance pu ores.if this product or material fails to,perform in the accepted mantner,.the manufacturer will incur the'expense of suc i testing and the,AHJ may immediately revoke,,modify,or suspend the use of sueh,pmduct or material.within their iui sdiction. RER reserves the,rightto revoke this,acceptance,if t'is determined by Miami-Dade'Cotfnty Produ't Control Section'that this product or material fails to meettlie requireements• of the applicable building code. This product is approved as described her 'n,and has been designed to'comply with the Florida Building Code including the High Velocity F3urricane Zo e:of the,Florida Building Code. DESCRIPT,TON 26 ga.Coastal 5V Ro f Panel LABELING: Each unit shall bear aper anent label with the manufacturer's naive or loge;city,state and following statement: "Miami-Dade County,Product ontrol Approved",unless otherwise noted herein. RENEWAL of.this NOA shall be consi red:after a renewal application has been.filed and there has been no change in the applicable building code negativel affecting the,performance of this product., TERMINATION of this NOA will occ atter the expiration date,or if there has been a:revision or change in the materials,use,and/or manufacture of the 'roduct or process-Misuse of this NOA as an endorsement of any product,for sales,advertising or any outer purposes s all automatically terminate this?�OA.Failure to comply with any section of, this NOA shall be cause for termination d removal ofN©A. ADVERTISEMENT: The NOA numb r precededby the words:Miami-Dade County, Florida,and followed by the. expiration date rnt iy be displayed in adve Using literature, if any portion of'the NOA.is displayed;then it shall be done In its entirety. INSPECTION:'A copy of this,entire N, A shalt be provided to the uset by the manufacturer or its distributors and shall.be available for inspection at.the jo site at the request.ofthe Building Official. This NOA renews NOA# 14-0520.02 an .consists of pates l through°5. The submitted documentation was revie_ ed by Alex'Tigera. NOA No.. 190807.02 tuwtaca�sO caI Expiration Rate 08/21/24 IAPPRApproval.Date:68/15/19 Page 1 of.5. ,ROOFING SYSTEM APPROVAL: Cateaorv: :Roofing Sub-Category: Metal',Pan Is(Non-Structural) Material: Steel Deck.Type: Wood Maximum DesiLyn Pressure 456.5 psf' TRADE NAMES OF-PRODUCTS.MA UFACTURED OR LABFLED.BY APPLICANT: Test Product Product Dimension i Specificati6tis Description 26 ga.Coastal 5V- I—varies TAS 110 Corrosion resistant, galvanized;.pr..eformed.. Crimp R:.00fPanel w=26" Valspar coated,prefinished,metal panels. (24"covera :11.:=3/8" Min.Thickness .0.1.8" (26ga.) Min.Yield,Stren h:67ksi. Trim'.Pieces 1—varies TAS 110 :Standard flashing and.trim°pieces. w=vafiel Manufactured for each panel width. Min.Thickness, ;:018" (26ga.) l!!IANUFACTURING LOCATION: L Horseshoe,Beach,FL: 2. Sebring,FL. 3. Stuart,FL. ]EVIDENCE SUBMITTEW TeKAP-ency Test Identifier Fest Name/Reoort Date PRI Construction Materials: VLS-004-02-01 ASTM G 155 02/22/13 Technologies VLS-005=02-01 A. STM G 23 02/22/13-, Force Engineering,,&Testing Inc. 4.7-0065T-07A-C TAS 125 081021,13: Farabaugh Engineering and '17215-08A. TAS 100 08/13/14 Testing,Inc. NOA No:: 19-({807:112 tyt"+.oaaeouN7Y Expiration'Date;08/21/24 Approval Dater 08115/19 Page 2 of 5 i APPROVED.ASSEMliLIES: System A: 26 ga.Coastal 5 -Crimp Roof Panel' Deck"Type: Wood,Non-ins ated Deck DesCriti p `QiM: , New:C.onstructi n''g.32"orgreater plywood or woad plank,.or for.re-roofing 1�/Por greater plywood. Maximum Uplifit" See Table A be awi Pressure: DeckAttachment: In accordance fth applicable Building Code, but in no case shall.it be less than 8d Wring shank nails spaed 6o.c. In reroofing, where the deck is less than,'�12" thick(IVlinimu►n j t A2'Tthe abov attachment method must be in addition to existing attachment. Underlayment: Minimum undo ayment shall he;an ASTM D 226"Type 11 installed with a minimum 4"side lap and 6"end-t ps. Underlayment shall be fiastened with cotrosion.resistant.tin-caps and.12 gauge.1 'l"ann; lar An nails,spaced 6"ox.at all laps and two staggered rows 12" o.c. in thefield "f the roil.Or,any approved underlayment Having a current NOA. Fire Barriers Any approved.'I re barrier having"a current NOA Refer to a current fire directory listing for firexatings ofti, sxoobng system°assembly as well as the location of the ire harrier within: ! the assembly. ee Limitation#`1. Valleys: Valley construc ion.shall be incoinpliance With Roofing Application Standards RAS 133 and with Gulf Coas Supply&Manufacturing LLC's current published installation;insiructions. Metal Panels and Install the"26 E i,Coastal SV-Crimp Roof Panel" and accessories in compliance.with Gulf Accessories: Coast Supply 8 Manufacturing LLC's-current,published installation instructions and.detai s. Flashing,penet ations,.valley construction and other details:shalLbe constructed.in compliance wi i4fie minimum requirements-provided in Roofing Application"Standards RAS 133. Panel fasteners hall be#9-1.5`x 1-W`self drilling,self tapping;hex bead,Jcrew-s'with sealing" washer of suffi "lent length to penetrate through the sheathing a minimuni:of 3f16:inch. Fasteners shall be,installed at.a maximum spat ng.:as,listed in Table A below parallel to:the slope. Fastene's shall be installe.d.at a maximum of-12"-o.c.at panel edge. See detail,hereiri TABLE A Mt1MMUllt DESIGN PRESSURES' Ronf,Areas. Field _. ... Perimeter and Corners Maximum Design Pressures -108.5 psf 456:5 pit Maximum.FAstener S ricin l,.",Extra olation-shall not be allowed NOA No.: i9"08tl7 u2 ► uu�t aoacotattry Explration.Date 0841/24 Approval Date:08/15/19 LIMITATIONS I., Fire classification.is not part of this a ceptance;refer to:a current Approved.Roofing Materials Directory for fire: ratings.of thisleproduct. 2. The niaxirnutn designed-pressure list d herein shall be applicable to all roof pressure zones(Le.,field, perimeters, And corners):Neither rational analysi ,nor extrapolation shall.be permitted for enhanced fastening at.enhaneed pressure zones(Le,perimeters,erten ed comers and.corners). 3. Panel shall.be roll`formed in.contin ous lengths from eave to ridge.Maximum lengths shalt be described'in the Roofing Application Standard RAS: 33, 4. All panels,shall be permanently lab ed with the manufacturer's name,and/or logo, and the following statement: "Miami-Dade County. Product Cont, 'I Approved"or with the Miami-Dade County Product Control Seal as seen below. All clips shall be permanent) labeled with the,manufacturer'"s:name anWor logo,and/or model. 1•DAD COUt '9( FYI '0 5. All;products listed herein;sha€l have . quality-assurance audit.in accotdanee with the Florida Building Code and .Rule 610.29-3 of the Florida Admin trative Code.. NOA No;: 39-08,07.02 n�rsan�cournry Expiration Date:08/21/24 Approval'Date:,08/15/1:9- Page.4..of S PRo a DRAWINGS 'DETAIL,A; 26 G COASTAL SV CRIMP Road ,,AN '24! Coverage. #9 15 x 1.1/2'`Vtilood ,ip Screw` #9-1.5 x 1!2"Woodgrip•Screw E SV-Onmp.Panel Mo�stuce Barrier;'. , Pty wood'Decking . :(Byoth'ers) =(Bqafhers) SeeTab A. +Herein* r•Maximurn' ' Fasteni Spacing 'E SV Panel: E D OF THtS ACCEPTANCE ' NOA No. 19=0$07 02: Muae�tiottrrrir Exp•raton Date Q$�2112 • Approval Date 0$f.X /1# :Page Sof`.;5