Loading...
HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Roof, Truss and wall frame repair Project Address: 1137 Percival Street, Fort Pierce, FL Permit #: 2007-0647 Occupancy Type: Residential Construction Type: 1A INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Sixth Edition with 2017 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: I X II III IV Exposure Category: X B C D 4. Design Wind Velocity. 160 mph ASD X LRFD End Zone Width: ft 5. Mean Roof Height ! 1 - 56 ft Roof Pitch: 4' 2 :12 Parapet: 'N (ft ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1:-VA A Zone 2: Zone 3: Zone 4: Zone 5: Garage: 7. Design Loads: Floor: 1 D D PSF Roof/Dead: I PSF Roof/Live: 20 Balcony: N 1A PSF Dock: PJ JA PSF Deck: NIA PSF Stairs: /y1A PSF Fence: >'J/A PSF Railings: IVM PSF 8. Were Shear Walls Considered For Structure? 'Yes XNot Applicable Explain Why Not: -r ,5:x/54c-R S,kLue4on.e does o7al AAve S.Aei;n wc)11S. 9. Is A Continuous Load Path Provided?_ )(_Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure:/PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: \�e �114 A4 ,N� gyp`%CE i y ifs. *.65195 t agGalure, Date,'bnd Seal 0T'•9 / 3 202�= l/ljRl\ Print Name Shahin M. Shafiq, P.E. Cert # & Co. Cert Auth. 7721 NW 16 CT, Pembroke Pines, FL 33024 Company Name & Address