Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Reside nti I Pe q r2 tttod-i Project Name: TESTA RESIDENCE Builder Name: ®� ?19 Street: Permit Office: ST LUCIE COLINLAUG City, State, Zip: FORT PIERCE, FL, Permit Number: cie County, Permitting Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or eAsting New (From Plans) 9. Wall Types (2800.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Polystyrene Bead AggrER=9.0 2800.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2625.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 2625.00 ft2 6. Conditioned floor area above grade (ft2) 2625 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows (588.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 200 a. U-Factor: Sgl, U=0.65 396.00 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 192.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 46.5 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 4.480 ft. Area Weighted Average SHGC: 0.266 14. Hot water systems a. Natural Gas Tankless Cap: 1 gallonsEF:0.800 8. Floor Types (2625.0 sqft.) Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 2625.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.224 Total Proposed Modified Loads: 79.05 PASS Total Baseline Loads: 91.05 I hereby certify that the plans and specifications covered by Review of the plans and '10% E this calculation are in compliance with the Florida Energy specifications covered by this „y� =.� ;�0 Code. calculation indicates compliance y, �ii, '' �•�� with the Florida Energy Code. PREP ED Y: DATE: - Before construction is completed this building will be inspected for,, compliance with Section 553.908 ---��~ I hereby certify that this b 'Iding, as designed, is in compliance Florida Statutes.;; y'C with the Florida Energy C COb WE OWNER/ NT. BUILDING OFFICIAL: DATE: d°� DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY 6/3/2019 2:36 PM EnergyGauge® USA Section R405.4.1 Compliant Software B OGC Page 1 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: TESTA RESIDENCE Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 2625 Lot # Owner Name: Total Stories: 1 Block/SubdhAsion: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Epsting: New (From Plans) Comment: CLIMATE v Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2625 29286 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 M BATH 234 2340 No 0 1 Yes Yes Yes 2 M TOILET 27 270 No 0 1 Yes Yes Yes 3 BATH 2 45 450 No 0 1 Yes Yes Yes 4 BEDROOM 2 220 2200 No 0 1 1 Yes Yes Yes 5 M WIC 128 1280 No 0 1 No Yes Yes 6 MASTER BEDROO 378 3780 No 0 1 1 Yes Yes Yes 7 HALLWAY 60 600 No 0 1 No Yes Yes 8 CLST 2 12 120 No 0 1 No Yes Yes 9 HALF BATH 36 360 No 0 1 No Yes Yes 10 OFFICE 255 2550 No 0 1 Yes Yes Yes 11 FOYER 81 810 No 0 1 Yes Yes Yes 12 LINEN CLST 12 120 No 0 1 No Yes Yes 13 AHU CLST 8 80 No 0 1 No Yes Yes 14 LAUNDRY 90 900 No 0 1 No Yes Yes 15 PANTRY 20 200 No 0 1 No Yes Yes 16 WINE RM 20 200 No 0 1 Yes Yes Yes 17 HALL 30 300 No 0 1 Yes Yes Yes 18 DINING ROOM 210 2100 No 0 1 Yes Yes Yes 19 KITCHEN 272 3808 Yes 0 1 No Yes Yes 20 GREAT ROOM 487 6818 No 0 1 Yes Yes Yes 6/3/2019 2:36 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation M BATH 43 ft 0 234 ft2 ____ 1 0 0 2 Slab -On -Grade Edge Insulation M TOILET 3 ft 0 27 ftZ ____ 1 0 0 3 Slab -On -Grade Edge Insulation BATH 2 5 ft 0 45 ft2 1 0 0 4 Slab -On -Grade Edge Insulation BEDROOM 2 22 ft 0 220 ft2 ____ 1 0 0 5 Slab -On -Grade Edge Insulation M WIC 1 ft 0 128 ft2 1 0 0 6 Slab -On -Grade Edge Insulation MASTER BEDRO 39 ft 0 378 ft2 1 0 0 7 Slab -On -Grade Edge Insulation HALLWAY 1 ft 0 60 ft2 ____ 1 0 0 8 Slab -On -Grade Edge Insulation CLST 2 1 ft 0 12 ft2 ____ 1 0 0 9 Slab -On -Grade Edge Insulation HALF BATH 1 ft 0 36 ft2 ____ 1 0 0 10SIab-On-Grade Edge Insulation OFFICE 23 ft 0 255 ft2 ____ 1 0 0 11SIab-On-Grade Edge Insulation FOYER 18 ft 0 81 ft2 1 0 0 12SIab-On-Grade Edge Insulation LINEN CLST 1 ft 0 12 ft2 1 0 0 13SIab-On-Grade Edge Insulation AHU CLST 1 ft 0 8 ft2 1 0 0 14SIab-On-Grade Edge Insulation LAUNDRY 1 ft 0 90 ft2 ____ 1 0 0 15SIab-On-Grade Edge Insulation PANTRY 1 ft 0 20 ft2 ____ 1 0 0 16SIab-On-Grade Edge Insulation WINE RM 4 ft 0 20 ft2 ____ 1 0 0 17SIab-On-Grade Edge Insulation HALL 6 ft 0 30 ft2 ___ 1 0 0 18SIab-On-Grade Edge Insulation DINING ROOM 33 ft 0 210 ft2 1 0 0 19SIab-On-Grade Edge Insulation KITCHEN 1 ft 0 272 ft2 1 0 0 20SIab-On-Grade Edge Insulation GREAT ROOM 60 ft 0 487 ft2 ____ 1 0 0 ROOF v Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 2936 ft2 0 ft2 Light 0.6 No 0.9 No 20 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2625 ft2 N N 6/3/2019 2:36 PM EnergyGaugeB USA Section R405.4.1 Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) M BATH 20 Blown 234 ft2 0.1 Wood 2 Under Attic (Unvented) M TOILET 20 Blown 27 ft2 0.1 Wood 3 Under Attic (Unvented) BATH 2 20 Blown 45 ft2 0.1 Wood 4 Under Attic (Unvented) BEDROOM 2 20 Blown 220 ft2 0.1 Wood 5 Under Attic (Unvented) M WIC 20 Blown 128 ft2 0.1 Wood 6 Under Attic (Unvented) MASTER BEDRO 20 Blown 378 ft2 0.1 Wood 7 Under Attic (Unvented) HALLWAY 20 Blown 60 ft2 0.1 Wood 8 Under Attic (Unvented) CLST 2 20 Blown 12 ft2 0.1 Wood 9 Under Attic (Unvented) HALF BATH 20 Blown 36 ft2 0.1 Wood 10 Under Attic (Unvented) OFFICE 20 Blown 255 ft2 0.1 Wood 11 Under Attic (Unvented) FOYER 20 Blown 81 ft2 0.1 Wood 12 Under Attic (Unvented) LINEN CLST 20 Blown 12 ft2 0.1 Wood 13 Under Attic (Unvented) AHU CLST 20 Blown 8 ft2 0.1 Wood 14 Under Attic (Unvented) LAUNDRY 20 Blown 90 ft2 0.1 Wood 15 Under Attic (Unvented) PANTRY 20 Blown 20 ft2 0.1 Wood 16 Under Attic (Unvented) WINE RM 20 Blown 20 ft2 0.1 Wood 17 Under Attic (Unvented) HALL 20 Blown 30 ft2 0.1 Wood 18 Under Attic (Unvented) DINING ROOM 20 Blown 210 ft2 0.1 Wood 19 Under Attic (Unvented) KITCHEN 20 Blown 272 ft2 0.1 Wood 20 Under Attic (Unvented) GREAT ROOM 20 Blown 487 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space R-1/al, le Ft In Ft In Area RA/alue Fraction AhSor r.rarip% 1 N Exterior Concrete Block - Polystyrerfd BATH 9 14 0 1.0 0 140.0 ft2 0 0 0.6 0 2 S Exterior Concrete Block - PolystyrerM BATH 9 8 0 10 0 80.0 ft2 0 0 0.6 0 3 W Exterior Concrete Block - PolystyrerM BATH 9 21 0 10 0 210.0 ft2 0 0 0.6 0 4 N Exterior Concrete Block - PolystyrdhbTOILET 9 3 0 10 0 30.0 ft2 0 0 0.6 0 5 N Exterior Concrete Block - Polystyren®ATH 2 9 5 0 10 0 50.0 ft2 0 0 0.6 0 6 N Exterior Concrete Block - PolystyFffiIDROOM 2 9 14 0 10 0 140.0 ft2 0 0 0.6 0 7 E Exterior Concrete Block - PolystyhMIDROOM 2 9 5 0 10 0 50.0 ft2 0 0 0.6 0 8 W Exterior Concrete Block - PolystyiillilDROOM 2 9 3 0 10 0 30.0 ft2 0 0 0.6 0 9 S Exterior Concrete Block - PolystyTER BE 9 21 0 10 0 210.0 ft2 0 0 0.6 0 10 W Exterior Concrete Block - PolystyTER BE 9 18 0 10 0 180.0 ft2 0 0 0.6 0 11 N Exterior Concrete Block - Polystyrer@FFICE 9 17 0 10 0 170.0 ft2 0 0 0.6 0 12 E Exterior Concrete Block - Polystyrer@FFICE 9 6 0 10 0 60.0 ft2 0 0 0.6 0 13 N Exterior Concrete Block - Polystyren€DYER 9 9 0 10 0 90.0 ft2 0 0 0.6 0 14 E Exterior Concrete Block - PolystyrenEOYER 9 9 0 10 0 90.0 ft2 0 0 0.6 0 15 S Exterior Concrete Block - PolystyreNNE RM 9 4 0 10 0 40.0 ft2 0 0 0.6 0 _ 16 S Exterior Concrete Block - PolystyreneHALL 9 6 0 10 0 60.0 ft2 0 0 0.6 0 17 E Exterior Concrete Block - PolystyMUNG ROO 9 9 0 10 0 90.0 ft2 0 0 0.6 0 18 S Exterior Concrete Block - Polystyfi MNG ROO 9 15 0 10 0 150.0 ft2 0 0 0.6 0 19 W Exterior Concrete Block - PolystyfiMNG ROO 9 9 0 10 0 90.0 ft2 0 0 0.6 0 20 N Exterior Concrete Block - PolystyGREAT ROO 9 15 0 14 0 210.0 ft2 0 0 0.6 0 6/3/2019 2:36 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below # Ornt In Wall lype21 Space E Exterior Concrete Block - PolystyGREAT ROO 9 22 0 14 0 308.0 ft2 0 0 0.6 0 22 S Exterior Concrete Block - Polysty@REAT ROO 9 23 0 14 0 322.0 ft2 0 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated FOYER None .39 3 8 24 ft2 2 S Insulated HALL None .39 3 8 24 ft2 WINDOWS . Orientation shown is the entered, Proposed orientation. / Wall Overhang V/ # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Single Yes 0.65 0.25 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None 2 N 1 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft2 2 ft 0 in 1 ft4 in Drapes/blinds Exterior 5 3 S 2 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft2 2 ft 0 in 1 ft4 in Drapes/blinds Exterior 5 4 W 3 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft2 2 ft 0 in 1 ft4 in Drapes/blinds Exterior 5 5 W 3 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 6 N 4 Metal Low-E Single Yes 0.65 0.25 N 8.0 ft2 2 ft 0 in 1 ft 4 in None None 7 N 5 Metal Low-E Single Yes 0.65 0.25 N 8.0 ft2 2 ft 0 in 1 ft 4 in None None 8 N 6 Metal Low-E Single Yes 0.65 0.25 N 45.0 ft2 2 ft 0 in 1 ft4 in None None 9 S 9 Metal Low-E Single Yes 0.65 0.3 N 48.0 ft2 2 ft 0 in 1 ft 4 in None None 10 W 10 Metal Low-E Single Yes 0.65 0.25 N 36.0 ft2 2 ft 0 in 1 ft 4 in None None 11 N 11 Metal Low-E Single Yes 0.65 0.25 N 36.0 ft2 2 ft 0 in 1 ft 4 in None None 12 N 13 Metal Low-E Single Yes 0.65 0.25 N 36.0 ft2 2 ft 0 in 1 ft 4 in None None 13 E 17 Metal Low-E Single Yes 0.65 0.25 N 36.0 ft2 5 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 14 S 18 Metal Low-E Single Yes 0.65 0.25 N 54.0 ft2 5 ft 0 in 1 ft4 in Drapes/blinds Exterior 5 15 W 19 Metal Low-E Single Yes 0.65 0.25 N 36.0 ft2 5 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 16 N 20 Metal Low-E Single Yes 0.65 0.3 N 48.0 ft2 8 ft 0 in 1 ft 4 in Drapes/blinds None 17 E 21 Metal Low-E Single Yes 0.65 0.25 N 36.0 ft2 8 ft 0 in 1 ft 4 in Drapes/blinds None 18 S 22 Metal Low-E Single Yes 0.65 0.3 N 96.0 ft2 8 ft 0 in 1 ft 4 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000496 3416.7 187.57 352.76 .3973 7 6/3/2019 2:36 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 46.5 kBtu/hr 1395 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Exterior 0.8 1 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS -- Supply -- -- Return — Air CFM 25 CFM25 HVAC # \/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 200 ft2 Attic 20 ft2 Default Leakage Attic (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb HeatinJan Feb Mar Mar Apr Apr May X Jun X Jul May Jun f Jul X Aug Aug Se Sep Oct Oct Nov Dec Dec Ventin Jan Feb X Mar X (X] A r [ Ma [ Jun [ Jul [ Au Se [X] Oct XNov X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 6/3/2019 2:36 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8lbs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALF BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 OFFICE Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 LINEN CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 PANTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 WINE RM Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING ROOM Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/s .ft. ft2 ft 0.3 GREAT ROOM Name: Signature: e:s)MQU::Q12;�Q-yV Rating Compant: Date: u — 1 5 6/3/2019 2:36 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 7 of 7 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: TESTA RESIDENCE Builder Name: Street: Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Y U Owner: Jurisdiction: ST LUCIE COUNTY w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA, General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the boftorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind Nning and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. in addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 6/3/2019 2:36 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 87 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 46.5 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2625 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.266 14. Heating system: Capacity 34.0 c) Area 7c. 588.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF b) Gas fired, natural gas EF 0.80 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 9.0 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 20.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: Z (D I h-�1� �)d as City/FL Zip: FORT PIERCE, FL 51�1 W 6/3/2019 2:36:50 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1