HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Reside nti I Pe q r2 tttod-i
Project Name: TESTA RESIDENCE
Builder Name:
®� ?19
Street:
Permit Office: ST LUCIE COLINLAUG
City, State, Zip: FORT PIERCE, FL,
Permit Number:
cie County, Permitting
Owner:
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or eAsting
New (From Plans)
9. Wall Types (2800.0 sqft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Polystyrene Bead AggrER=9.0 2800.00 ft2
b. N/A
R= ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
2
d. N/A
R= ft2
5. Is this a worst case?
No
10. Ceiling Types (2625.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 2625.00 ft2
6. Conditioned floor area above grade (ft2)
2625
b. N/A
R= ft2
Conditioned floor area below grade (ft2)
0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows (588.0 sqft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 200
a. U-Factor: Sgl, U=0.65
396.00 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.65
192.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.30
a. Central Unit
46.5 SEER:16.00
c. U-Factor: N/A
ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A
ft2
a. Electric Strip Heat
34.0 COPA.00
SHGC:
Area Weighted Average Overhang Depth:
4.480 ft.
Area Weighted Average SHGC:
0.266
14. Hot water systems
a. Natural Gas Tankless
Cap: 1 gallonsEF:0.800
8. Floor Types (2625.0 sqft.)
Insulation Area
a. Slab -On -Grade Edge Insulation
R=0.0 2625.00 ft2
b. Conservation features
b. N/A
R= ft2
None
c. N/A
R= ft2
15. Credits
None
Glass/Floor Area: 0.224
Total Proposed Modified Loads: 79.05
PASS
Total Baseline Loads: 91.05
I hereby certify that the plans and specifications covered by
Review of the plans and
'10% E
this calculation are in compliance with
the Florida Energy
specifications covered by this
„y� =.� ;�0
Code.
calculation indicates compliance
y, �ii, '' �•��
with the Florida Energy Code.
PREP ED Y:
DATE: -
Before construction is completed
this building will be inspected for,,
compliance with Section 553.908
---��~
I hereby certify that this b 'Iding, as designed, is in compliance
Florida Statutes.;;
y'C
with the Florida Energy C
COb WE
OWNER/ NT.
BUILDING OFFICIAL:
DATE: d°�
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
6/3/2019 2:36 PM EnergyGauge® USA Section R405.4.1 Compliant Software B OGC Page 1 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
TESTA RESIDENCE
Bedrooms:
2
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2625
Lot #
Owner Name:
Total Stories:
1
Block/SubdhAsion:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
Rotate Angle:
0
Street:
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL,
New/Epsting:
New (From Plans)
Comment:
CLIMATE
v
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2625
29286
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
M BATH
234
2340 No
0
1
Yes
Yes
Yes
2
M TOILET
27
270 No
0
1
Yes
Yes
Yes
3
BATH 2
45
450 No
0
1
Yes
Yes
Yes
4
BEDROOM 2
220
2200 No
0
1
1
Yes
Yes
Yes
5
M WIC
128
1280 No
0
1
No
Yes
Yes
6
MASTER BEDROO
378
3780 No
0
1
1
Yes
Yes
Yes
7
HALLWAY
60
600 No
0
1
No
Yes
Yes
8
CLST 2
12
120 No
0
1
No
Yes
Yes
9
HALF BATH
36
360 No
0
1
No
Yes
Yes
10
OFFICE
255
2550 No
0
1
Yes
Yes
Yes
11
FOYER
81
810 No
0
1
Yes
Yes
Yes
12
LINEN CLST
12
120 No
0
1
No
Yes
Yes
13
AHU CLST
8
80 No
0
1
No
Yes
Yes
14
LAUNDRY
90
900 No
0
1
No
Yes
Yes
15
PANTRY
20
200 No
0
1
No
Yes
Yes
16
WINE RM
20
200 No
0
1
Yes
Yes
Yes
17
HALL
30
300 No
0
1
Yes
Yes
Yes
18
DINING ROOM
210
2100 No
0
1
Yes
Yes
Yes
19
KITCHEN
272
3808 Yes
0
1
No
Yes
Yes
20
GREAT ROOM
487
6818 No
0
1
Yes
Yes
Yes
6/3/2019 2:36 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
M BATH
43 ft
0
234 ft2
____
1
0
0
2 Slab -On -Grade Edge Insulation
M TOILET
3 ft
0
27 ftZ
____
1
0
0
3 Slab -On -Grade Edge Insulation
BATH 2
5 ft
0
45 ft2
1
0
0
4 Slab -On -Grade Edge Insulation
BEDROOM 2
22 ft
0
220 ft2
____
1
0
0
5 Slab -On -Grade Edge Insulation
M WIC
1 ft
0
128 ft2
1
0
0
6 Slab -On -Grade Edge Insulation
MASTER BEDRO
39 ft
0
378 ft2
1
0
0
7 Slab -On -Grade Edge Insulation
HALLWAY
1 ft
0
60 ft2
____
1
0
0
8 Slab -On -Grade Edge Insulation
CLST 2
1 ft
0
12 ft2
____
1
0
0
9 Slab -On -Grade Edge Insulation
HALF BATH
1 ft
0
36 ft2
____
1
0
0
10SIab-On-Grade Edge Insulation
OFFICE
23 ft
0
255 ft2
____
1
0
0
11SIab-On-Grade Edge Insulation
FOYER
18 ft
0
81 ft2
1
0
0
12SIab-On-Grade Edge Insulation
LINEN CLST
1 ft
0
12 ft2
1
0
0
13SIab-On-Grade Edge Insulation
AHU CLST
1 ft
0
8 ft2
1
0
0
14SIab-On-Grade Edge Insulation
LAUNDRY
1 ft
0
90 ft2
____
1
0
0
15SIab-On-Grade Edge Insulation
PANTRY
1 ft
0
20 ft2
____
1
0
0
16SIab-On-Grade Edge Insulation
WINE RM
4 ft
0
20 ft2
____
1
0
0
17SIab-On-Grade Edge Insulation
HALL
6 ft
0
30 ft2
___
1
0
0
18SIab-On-Grade Edge Insulation
DINING ROOM
33 ft
0
210 ft2
1
0
0
19SIab-On-Grade Edge Insulation
KITCHEN
1 ft
0
272 ft2
1
0
0
20SIab-On-Grade Edge Insulation
GREAT ROOM
60 ft
0
487 ft2
____
1
0
0
ROOF
v
Roof
Gable
Roof
Solar
SA Emitt
Emitt
Deck
Pitch
# Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Hip
Metal 2936 ft2
0 ft2
Light
0.6
No 0.9
No
20
26.6
ATTIC
/
V # Type
Ventilation
Vent Ratio (1
in)
Area
RBS IRCC
1 Full attic
Unvented
0
2625 ft2
N N
6/3/2019 2:36 PM EnergyGaugeB USA Section R405.4.1 Compliant Software Page 3 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) M BATH
20
Blown
234 ft2
0.1
Wood
2
Under Attic (Unvented) M TOILET
20
Blown
27 ft2
0.1
Wood
3
Under Attic (Unvented) BATH 2
20
Blown
45 ft2
0.1
Wood
4
Under Attic (Unvented) BEDROOM 2
20
Blown
220 ft2
0.1
Wood
5
Under Attic (Unvented) M WIC
20
Blown
128 ft2
0.1
Wood
6
Under Attic (Unvented) MASTER BEDRO 20
Blown
378 ft2
0.1
Wood
7
Under Attic (Unvented) HALLWAY
20
Blown
60 ft2
0.1
Wood
8
Under Attic (Unvented) CLST 2
20
Blown
12 ft2
0.1
Wood
9
Under Attic (Unvented) HALF BATH
20
Blown
36 ft2
0.1
Wood
10
Under Attic (Unvented) OFFICE
20
Blown
255 ft2
0.1
Wood
11
Under Attic (Unvented) FOYER
20
Blown
81 ft2
0.1
Wood
12
Under Attic (Unvented) LINEN CLST
20
Blown
12 ft2
0.1
Wood
13
Under Attic (Unvented) AHU CLST
20
Blown
8 ft2
0.1
Wood
14
Under Attic (Unvented) LAUNDRY
20
Blown
90 ft2
0.1
Wood
15
Under Attic (Unvented) PANTRY
20
Blown
20 ft2
0.1
Wood
16
Under Attic (Unvented) WINE RM
20
Blown
20 ft2
0.1
Wood
17
Under Attic (Unvented) HALL
20
Blown
30 ft2
0.1
Wood
18
Under Attic (Unvented) DINING ROOM
20
Blown
210 ft2
0.1
Wood
19
Under Attic (Unvented) KITCHEN
20
Blown
272 ft2
0.1
Wood
20
Under Attic (Unvented) GREAT ROOM
20
Blown
487 ft2
0.1
Wood
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing Solar
Below
Space
R-1/al, le
Ft In
Ft
In
Area
RA/alue
Fraction
AhSor
r.rarip%
1
N
Exterior Concrete Block - Polystyrerfd BATH
9
14
0 1.0
0
140.0 ft2
0
0
0.6
0
2
S
Exterior Concrete Block - PolystyrerM BATH
9
8
0 10
0
80.0 ft2
0
0
0.6
0
3
W
Exterior Concrete Block - PolystyrerM BATH
9
21
0 10
0
210.0 ft2
0
0
0.6
0
4
N
Exterior Concrete Block - PolystyrdhbTOILET
9
3
0 10
0
30.0 ft2
0
0
0.6
0
5
N
Exterior Concrete Block - Polystyren®ATH 2
9
5
0 10
0
50.0 ft2
0
0
0.6
0
6
N
Exterior Concrete Block - PolystyFffiIDROOM 2
9
14
0 10
0
140.0 ft2
0
0
0.6
0
7
E
Exterior Concrete Block - PolystyhMIDROOM 2
9
5
0 10
0
50.0 ft2
0
0
0.6
0
8
W
Exterior Concrete Block - PolystyiillilDROOM 2
9
3
0 10
0
30.0 ft2
0
0
0.6
0
9
S
Exterior Concrete Block - PolystyTER BE
9
21
0 10
0
210.0 ft2
0
0
0.6
0
10
W
Exterior Concrete Block - PolystyTER BE
9
18
0 10
0
180.0 ft2
0
0
0.6
0
11
N
Exterior Concrete Block - Polystyrer@FFICE
9
17
0 10
0
170.0 ft2
0
0
0.6
0
12
E
Exterior Concrete Block - Polystyrer@FFICE
9
6
0 10
0
60.0 ft2
0
0
0.6
0
13
N
Exterior Concrete Block - Polystyren€DYER
9
9
0 10
0
90.0 ft2
0
0
0.6
0
14
E
Exterior Concrete Block - PolystyrenEOYER
9
9
0 10
0
90.0 ft2
0
0
0.6
0
15
S
Exterior Concrete Block - PolystyreNNE RM
9
4
0 10
0
40.0 ft2
0
0
0.6
0
_ 16
S
Exterior Concrete Block - PolystyreneHALL
9
6
0 10
0
60.0 ft2
0
0
0.6
0
17
E
Exterior Concrete Block - PolystyMUNG ROO
9
9
0 10
0
90.0 ft2
0
0
0.6
0
18
S
Exterior Concrete Block - Polystyfi MNG ROO
9
15
0 10
0
150.0 ft2
0
0
0.6
0
19
W
Exterior Concrete Block - PolystyfiMNG ROO
9
9
0 10
0
90.0 ft2
0
0
0.6
0
20
N
Exterior Concrete Block - PolystyGREAT ROO
9
15
0 14
0
210.0 ft2
0
0
0.6
0
6/3/2019 2:36 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing Solar
Below
# Ornt
In
Wall
lype21
Space
E
Exterior
Concrete Block - PolystyGREAT ROO 9
22
0
14 0
308.0 ft2
0
0 0.6
0
22 S
Exterior
Concrete Block - Polysty@REAT ROO 9
23
0
14 0
322.0 ft2
0
0 0.6
0
DOORS
#
Ornt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
E
Insulated
FOYER
None
.39
3
8
24 ft2
2
S
Insulated
HALL
None
.39
3
8
24 ft2
WINDOWS
.
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V/ #
Ornt
ID
Frame
Panes
NFRC
U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N
1
Metal
Low-E Single
Yes
0.65
0.25
N
6.0 ft2
2 ft 0 in
1 ft 4 in
None
None
2
N
1
Metal
Low-E Single
Yes
0.65
0.25
N
12.0 ft2
2 ft 0 in
1 ft4 in
Drapes/blinds
Exterior 5
3
S
2
Metal
Low-E Single
Yes
0.65
0.25
N
12.0 ft2
2 ft 0 in
1 ft4 in
Drapes/blinds
Exterior 5
4
W
3
Metal
Low-E Single
Yes
0.65
0.25
N
20.0 ft2
2 ft 0 in
1 ft4 in
Drapes/blinds
Exterior 5
5
W
3
Metal
Low-E Single
Yes
0.65
0.25
N
15.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
6
N
4
Metal
Low-E Single
Yes
0.65
0.25
N
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
7
N
5
Metal
Low-E Single
Yes
0.65
0.25
N
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
8
N
6
Metal
Low-E Single
Yes
0.65
0.25
N
45.0 ft2
2 ft 0 in
1 ft4 in
None
None
9
S
9
Metal
Low-E Single
Yes
0.65
0.3
N
48.0 ft2
2 ft 0 in
1 ft 4 in
None
None
10
W
10
Metal
Low-E Single
Yes
0.65
0.25
N
36.0 ft2
2 ft 0 in
1 ft 4 in
None
None
11
N
11
Metal
Low-E Single
Yes
0.65
0.25
N
36.0 ft2
2 ft 0 in
1 ft 4 in
None
None
12
N
13
Metal
Low-E Single
Yes
0.65
0.25
N
36.0 ft2
2 ft 0 in
1 ft 4 in
None
None
13
E
17
Metal
Low-E Single
Yes
0.65
0.25
N
36.0 ft2
5 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
14
S
18
Metal
Low-E Single
Yes
0.65
0.25
N
54.0 ft2
5 ft 0 in
1 ft4 in
Drapes/blinds
Exterior 5
15
W
19
Metal
Low-E Single
Yes
0.65
0.25
N
36.0 ft2
5 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
16
N
20
Metal
Low-E Single
Yes
0.65
0.3
N
48.0 ft2
8 ft 0 in
1 ft 4 in
Drapes/blinds
None
17
E
21
Metal
Low-E Single
Yes
0.65
0.25
N
36.0 ft2
8 ft 0 in
1 ft 4 in
Drapes/blinds
None
18
S
22
Metal
Low-E Single
Yes
0.65
0.3
N
96.0 ft2
8 ft 0 in
1 ft 4 in
Drapes/blinds
None
INFILTRATION
# Scope
Method
SLA CFM 50
ELA
EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50)
.000496
3416.7
187.57
352.76
.3973
7
6/3/2019 2:36 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Strip Heat/
None
COPA
34 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
SEER: 16
46.5 kBtu/hr
1395 cfm
0.8
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Natural Gas
Tankless
Exterior
0.8 1 gal 55.1 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector
Model # Area
Volume
FEF
None None
ft2
DUCTS
-- Supply --
-- Return —
Air
CFM 25
CFM25
HVAC #
\/ # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6 200 ft2
Attic
20 ft2 Default Leakage
Attic
(Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
CoolingJan Feb
HeatinJan Feb
Mar
Mar
Apr
Apr
May X Jun X Jul
May Jun f Jul
X Aug
Aug
Se
Sep
Oct
Oct
Nov
Dec
Dec
Ventin Jan Feb
X Mar
X
(X] A r
[ Ma [ Jun [ Jul
[ Au
Se
[X]
Oct
XNov
X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 80
80 78 78
78
78
78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 80
80 78 78
78
78
78
78
78
78
Heating (WD) AM
65
65 65
65 65 65
65
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
68
68
Heating (WEH) AM
65
65 65
65 65 65
65
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
68
68
6/3/2019 2:36 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 6 of 7
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M TOILET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8lbs/sq.ft.
ft2
ft
0.3
M WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALF BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
OFFICE
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LINEN CLST
Default(8 Ibs/sq.ft.
ft2
ft
0.3
AHU CLST
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
PANTRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WINE RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
DINING ROOM
Default(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/s .ft.
ft2
ft
0.3
GREAT ROOM
Name: Signature: e:s)MQU::Q12;�Q-yV
Rating Compant: Date: u — 1 5
6/3/2019 2:36 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 7 of 7
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: TESTA RESIDENCE Builder Name:
Street: Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Y
U
Owner: Jurisdiction: ST LUCIE COUNTY
w
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA,
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the boftorr
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring a
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind Nning and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. in addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
6/3/2019 2:36 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 87
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 2
13. Cooling system: Capacity
46.5
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 2625
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.650
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.266
14. Heating system: Capacity
34.0
c) Area
7c. 588.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
b) Gas fired, natural gas EF
0.80
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2. 9.0
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a. 20.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
f) Programmable thermostat
No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature:
Date:
Address of New Home: Z (D I h-�1�
�)d
as
City/FL Zip: FORT PIERCE, FL
51�1 W
6/3/2019 2:36:50 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software