Loading...
HomeMy WebLinkAboutProduct Approval 11 Florida Building.Code Online 9/9/20,6:37 PM toW.L?�y4 A lae. `5.i a o r BCIS Home I Login I User Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publications Contact Us I BCIS Site Map I Links I Search Florida IMMED -� Product Approval "USER:Public User SEP 1' ,0'' 2020 u;h;rci� e,Grrs Product Approval Menu>Product or Application Search>Application List>Application Detail Permitting Department St. LUcle County FL# FL9487-R5 Application Type Revision Code Version 2017 s^# o Application Status Approved 9' Comments Archived s '` Product Manufacturer Tarco Roofing {, Address/Phone/Email One Information Way Suite 225 Little Rock,AR 72202 (254) 913-7750 r rty'f smohseen@tarcoroofing.com Authorized Signature Shaik Mohseen m iii ,, '"x smohseen@tarcoroofing.cbm' iY r y.�. �� � P ;� , r � kr� CA� rCO Go � . x Technical Representative Shaik Mohseen �1C Address/Phone/Email 2403 Taylors Valley Road Belton,TX 76513- (254) 6513(254) 913-7750- smohseen@tarcoro6f!ng.com ti 1 rk, LIP Quality Assurance Representative CODY 4 fi r9T' Address/Phone/Email -File Category Roofing Subcategory Modified Bitumen Roof System t� meq' '+ t3 Compliance Method Evaluation Report from a-Florida Registered Architect or a Licensed Florida fe Cif �� Professional Engineer, Evaluation Report- Hardcopy Received err Florida Engineer or Architect Name.who developed r '-Robert J.M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date- 04/07/2023 Validated By John W. Knezevich, PE v Validation Checklist- Hardcopy Received Certificate of Independence FL9487 R COI 2017 01 COI Nieminen.pd F�h6 {fr Referenced Standard and Year(of Standard) Standard Year ASTM D226 2009 http://www.fIorid a building.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvn9icO%2fd%2f8N4sjUFFvwylvLPkj3P80CCo%3d Pagel of 2. Florida Building'Code Online 9/9/20,6:37 PM 4 r� " z- ASTM D4601 y; 2012 ins¢` ASTM D6163 2008 1 { Yfi � ASTM D6164 2011 tkii �' F`a FM 4470 2012 y , FM 4474 2011 Equivalence of Product Standards _. Certified By Sections from the Code {� Product Approval Method Method 1 Option D K f �TM Date Submitted 10/03/2017 Date Validated 10/07/2017 Date Pending FBCApproval 10/09/2017 Date Approved 12/12/2017 Summary of Products` FL,*, Model,Number'or Name Description 9487.1 LeakBarrier EasyStick Modified Self-Adhering Modified Bitumen Roof Systems Bitumen Roof Systems "r Limits of Use Installation Instructions < �sj Fr Approved for use in HVHZ: No r FL9487 R5--B 2017 10 FINAL Al FR T_ARCO MODBITSBS FL9487- ��„ roved fbr use outside HVHZ:Yes j_&Wff +_ k Impact'Resistant: N/A Verified By: Robert I.M. Nieminen PE- 59166 a ,Design'Press6r(i:•+N/A/-135 Created by Independent Thir&Party':Yes -Other: 1.)The design pressure in this application" Evaluation Reports relates to one particular assembly over concrete FL9487 R AE 2017 1 FINAL ER TARCO MODBIT SBS_FL9487_ VTI deck. Refer to the ER Appendix for other systems R5.pdf and deck types. 2.) Refer to ER, Section 5 for other Created by Independent Third Party: Yes r` Limits of Use. T � f�vei �; *144 a_ .i•1.��,• W7 WE Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 � ..T a Gayr _ +� K The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement 7" k eM- c A - Under Florida law;email addresses are public records.If you do not:want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a n 'a personal address,please provide the Department with an email address which can be made available to the public.To determine if you'are a licensee under Chapter 455,ES.,please click berg-. Product Approval Accepts: " Credit Card Safe vh 7 fi http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvn9icO%2fd%2f8N4sjUFFvwy1vLPkj3P80CCo%3d Page 2 of 2 EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization.#9503 \-JI TRINITY ERD 353 Christian Street, Unit 13 Oxford,CT 06478 (203)262-9245 EVALUATION REPORT Tarco Roofing. Evaluation Report T39820.12.11-R3 One Information Way,Suite 225' FL9487-R5 'Little Rock,AR 72202 Date of Issuance:'12/09/2011 (254)913-7750 Revision 3:10/02/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 61h Edition(2017)Florida Building Code sections noted herein. DESCRIPTION: LeakBarrier®EasyStick- Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is'valid until such time as the named product(s) changes,the referenced Quality Assurance documentation changes,or'provisions of the Code that relate to the product change.Acceptance of this Evaluation Report by the named client constitutes agreement to notify .Robert Nieminen, P.E. if the product changes or the.referenced Quality Assurance documentation changes. .Trinityl ERD requires a complete.review of this Evaluation Report relative to updated Code requirements with each Code Cycle.- ADVERTISEMENT: The Evaluation Report number preceded by the words "TRINITY ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done,in,its entirety.,, INSPECTION: Upon request, a,co,py of this entire.,Evaluation Report,shall be provided to the user by the manufacturer or its distributors and,shall be available for inspection.at the job site at the request of the Building Official.. This Evaluation Report consists of pages 1 through 4, plus a 3-page Appendix. ' .Prepared by: r ,QS7,ti::�11ty`�'�asi Robert J.M.Nieminen,P.E. : �; s ar''°` �q��FS�;Q ����_`,•'. The faclmllle seal appearing was authorized by Rohert Nieminen,P.E. Florida Registration No.59166,Florida DCAANE1983 �ry"�ON?� +d•". on10/02/2017.Thlsdoes not serve asanelectronically slgned document. , CERTIFICATION OF INDEPENDENCE: 1, Exterior Research&Design,LLC.d/b/a Trinity l ERD does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. Fy:) TRINI-ry I ER® ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Modified Bitumen Roof Systems Compliance Statement: LeakBarrier® EasyStick'" Modified Bitumen Roof Systems, as produced by:Tarco Roofing, have demonstrated compliance with the following sections of the 6th Edition(2017) Florida Building Code through testing in.accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/.Conditions of Use set forth herein. 2. STANDARDS: Section Prope Standard Year 1504.3.1 Wind TM 4.474 2011 1504.7 Impact FM 4470 2012 1507.10.2 Physical Properties ASTM D226 2009 1507.10.2 Physical Properties ASTM D4601 2012 1507.11.2 Physical Properties ASTM D6163 2008 1507.11.2 Physical Properties ASTM D6164 2011 3. REFERENCES: Entity, Examination Reference Date . PRI(TST5878) Physical Properties_ TOT-041-02-01 05/24/2006 ERD(TST6049) Wind-FM4470/4474 TAR-SC7960.01.16' 01/31/2016 'ERD(TST6049) Wind-FM4470/4474 TAR-SC5670.03.16 03/21/2016 ERD(TST6049)' Wind-FM4470/4474 T6460.06.07-R2 05/26/2017 ' ERD(TST6049) Physical Properties T6470.08.07-R2 06/02/2017 UL(QUA1743) Quality Assurance Service Confirmation Exp.06/28/2020 4. PRODUCT DESCRIPTION: This Evaluation Report covers LeakBarrier® EasyStick'"Modified Bitumen Roof Systems installed in'accordance with Tarco Roofing published installation instructions'and the L'im'itations / Conditions of Use herein. The following products make up the subject systems. . TABLE 1: ROLL-GOODS FOR LEAKBARRIER®EASYSTICKT"MODIFIED BITUMEN ROOF SYSTEMS Type Product Specification Reference Type Grade LeakBarrier®EasyLayT" ASTM D226 II N/A, Base Sheets: ASTM D4601 LeakBarrier®EasyNailBaseT"" II N/A (published) Smooth Surfaced Membranes: LeakBarrier®EasyBaseTM" ASTM D6163 I S, Granule Surfaced Membranes: LeakBarrier®EasyStickTM ASTM D6164 I G Exterior Research and Design,LLC. Evaluation Report T39820.12.11-R3 CertiJlcate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL9487-RS LeakBarrier®EasyStick Modified Bitumen Roof Systems Revision 3:10/02/2017 Page 2 of 4 TRINITY(ER® 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity ERD nor.Robert Nieminen, P.E.'are, in any way, the Designer of Record for any project on which this Evaluation,Report;or previous versions thereof,is/was used for permitting or design.guidance unless retained specifically:for that purpose. 5.2 This Evaluation,Report is not for use in FBC HVHZ jurisdictions: 5.3` Fire classification does not'form part of this Evaluation Report;refer to a current Approved Roofing Materials Directory for fire ratings of this'product. 5.4 For steel deck installations,foam plastic insulation shall be separated from the building interior in accordance with.FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction. of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper, codified And/or FBC Approval documentation. 5.6 For recover installations,the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically at#ached insulation or membrane or strip-bonded insulation,the•maAmum design pressure for the selected•assembly shall meet.or exceed the Zone'1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re-roof(tear off)or recover installation,the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1,ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3. Exterior Research and Design,U.C. Evaluation Report 739820.12:11-R3 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL9487-RS LeakBarrier®EasySttck Modified Bitumen Roof Systems. Revision 3:10/02/2017 Page 3 of 4 TRINI-Y f ER® 6. INSTALLATION: 6.1 EasyStick''AModified Bitumen Roof Systems shall be installed in accordance with Tarco Roofing published installation instructions,subject to.the Limitations/Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2,to,1 margin of safety per.FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. S. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: Underwriters Laboratories-QUA1743;(414)248-6409; Karen.buchmann@us.ul.com -THE THREE(3)PAGES THAT FOLLOWS FORMS PART OF THIS EVALUATION REPORT- Exterior EPORT-Exterior Research and Design,I.I.C. Evaluation Report T39820.12.11-R3 Certificate of Authorizat/on#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL9487-RS LeakBarrier®EasyStick Modified Bitumen Roof Systems Revision 3:10/02/2017 Page 4 of 4 F)0 , TRiNrry ER® APPENDIX Z:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description _ Page 1A Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,.Bonded Roof Cover 2 16 Wood New,Reroof(Tear-Off)or Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 2 SC-1 Wood New or Reroof(Tear-OfIl E Non-Insulated,Mech.Attached Base Sheet(nails),Bonded Roof Cover 2 1C-2 Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 3 1D Wood New or Reroof(Tear-Off) F- Non-Insulated,Bonded Roof Cover - 3 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise noted,fasteners and stress plates for insulation attachment shall be as follows.-Fasteners shall be of sufficient length for the following engagements:- Wood beck: OMG#12 or#14 HD with OMG 3 in.Galvalume Steel Plate(non-ribbed)orTru-Fast DP or HD with Trufast 3"Metal Insulation Plates. Minimum Y.-inch plywood penetration or minimum 1-inch wood plank embedment. _ 3. Unless otherwise noted,insulation may be any one layer or combination of polyisocyanurate,polystyrene,wood fiberboard,perlite or gypsum-based roof board that meets the QA requirements of F.A.C.Rule"61G20- 3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. 4. For mechanically attached components or partially bonded insulation,the maximum design pressure for the'selected assembly shall meet or exceed the Zone i design pressure determined in accordance with FBC Chapter 16, and Zones 2 and-3 shall employ an attachment density designed by a qualified design professional to resist the elevatedpressure criteria. -Commonly.usedimethods are ANSI/SPRI WDl, FM Loss Prevention Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carrythe limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 5. For assemblies where all components are fully adhered,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no - -rational analysis is permitted. 6. For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance.•A qualified design professional shall review the data for comparison to the - minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 orTesting Application Stanard TAS 105. 7. For existing substrates in a bonded recover or re-roof installation,the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive,and the existing roof system(for recover)shall be capable of resisting project design pressures on its-own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplifttesting in accordance with ANSI/SPRI IA-1,ASTM E907,FM Loss Prevention Data Sheet 1-52 orTesting Application Standard TAS 124. 8. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609.for.determination of design wind loads. Exterior Research and Design,LLC.d/b/a Trinity ERD Evaluation Report T39820.12.11-R3 for FL9487-RS Certificate of Authorization 119503 6EDITION(2017)FBC NON-HVHZ EVALUATION Revision 3:10/02/2017 Prepared by: Robert Nieminen,PE-59166 LeakBarder®EasyStick—Modified Bitumen Roof Systems;(254)913-7750 Appendix 1,Page 1 of 3 JTRINITY TABLE 1A: WOOD DECKS—NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Top Insulation Layer Roof Cover MDP No Deck(Note 1) Base Insulation Layer Type Fasteners Attach Base Ply Ply Cap (Psf) W-1. Min.15/32"plywood (Optional)One or more layers, Min.3/8-inch SECUROCK Gypsum- Note 2 1 per 1 ftZ EasyBase (Optional)EasyBase EasyStick Plus -525 at max.24"spans any combination,loose laid Fiber Roof Board Min.2-inch ACFoam II,EnergyGuard W-2. Min.15/32"plywood (Optional)One or more layers, Polyiso,ENRGY 3,H-Shield,ISO 95+ Note 2 1 per 1 ftZ EasyBase (Optional)EasyBase EasyStick Plus -82.5 at max.24"spans 'any combination,loose laid GL-or Mufti-Max FA3 TABLE 1B: WOOD DECKS—NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER SYSTEM TYPE D: INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck(Note 1) Insulation Layer Base Sheet Roof Cover MDP No. Type Attach Type Fasteners Attach Base Ply Cap (psf) W 3 Min.15/32"plywood Any.type,thickness or Loose laid EasyLay Note 2 10-inch o.c.in the min.4-inch lap and 10-inch o.c. One or two plies, EasyStick Plus -60.0 at max.24','spans combination in two(2),equally spaced,staggered center rows EasyBase W-4Min.15/32",plywood Any type,thickness or ' Loose laid EasyLay Note 2 8=inch o.c.in the min.4-inch lap and 8-inch o.c.in One or two plies, EasyStick Plus -135.0 at max.24"spans combination four(4),equally spaced,staggered center rows EasyBase W-5. Min.-15/32"plywood. Any type,thickness or Loose laid Easj NailBase Note 2 6-inch o.c.in the min.4-inch lap and 6-inch o.c.in . One ortwo plies, EasyStick Plus -135.0 at max.24"spans combination four(4),equally spaced,staggered center rows EasyBase TABLE IC-1: WOOD DECKS.—NEW CONSTRUCTION or REROOF(Tear-Off) SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(nails),BONDED ROOF COVER System Deck(Note 1)• Base Sheet Roof Cover MDP No. Type Fasteners Attach Base Ply Cap (Psf) Min.,19/32"plywood 12 ga.annular ring shank nails and min.32 ga.,l-5/8" 7-inch o.c.in the 4-inch lap and 7-inch o.c.in three One ortwo plies, W-6' EasyLay at max.24"spans -diameter tin-caps. (Ref: FBC 15175) (3),equally spaced,staggered center rows EasyBase EasyStick Plus -60.0 Min.15/32"plywood 8-inch o.c.in the min.4-inch lap and 8-inch o.c.in- One or two plies, W 7' at max.24"spans EasyLay Simplex MARX Cap Fastener four(4),equally spaced,staggered center rows EasyBase EasyStick Plus -825 Min.15/32"plywood 12 ga.annular ring shank nails and min.32 ga,1-5/8" 4-inch o.c.in the 4-inch lap and 4-inch o.c.in four One ortwo plies, W-8. EasyLay EasyStick Plus -120.0 at max.24"spans diameter tin-caps. (Ref: FBC 1517.5) - (4),equally spaced,staggered center rows EasyBase - Min.15/32"plywood 12 ga.annular ring shank nails and min.32 ga.,1-5/8" 4-inch o.c.in the 4-inch lap and 4-inch o.c.in five One or two plies, W-9. at max.24"spans EasyNailBase diameter tin-ca Ref: FBC 15175 (5),equally spaced,staggered center rows EasyBase EasyStick Plus -120.0 P tin-caps. ( ) ( ) q Y P gg Y Exterior Research and Design,I.I.C.d/b/a Trinity)ERD Evaluation Report T39820.12.11-R3 for FL9487-R5 Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 3.10/02/2017 Prepared by: Robert Nieminen,PE-59166 LeakBarrier®EasyStick'"'Modified Bitumen Roof Systems;(254)913-7750 Appendix 1,Page 2 of 3 QOTRINITYIERD TABLE 1C-2: WOOD DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(screws&plates),BONDED ROOF COVER System Base Sheet Roof Cover MDP No. Deck(Note i) Type Fasteners Attach Base Ply Cap (Pso W-10. Min.15/32"plywood EasyLay Note 2 10-inch o.c.in the min.4-inch lap and 30-inch o.c.in two(2),equally spaced, One or two plies, EasyStick Plus -60.0 at max.24"spans staggered center rows EasyBase W-11. Min.15/32"plywood EasyLay Note 2 8-inch o.c.in the min.4-inch lap and 8-inch o.c.in four(4),equally spaced, One or two plies, EasyStick Plus -135.0 at max.24"spans staggered center rows EasyBase W 12 Min.15/32"plywood EasyNailBase Note 2 6-inch o.c.in the min.4-inch lap and 6-inch o.c.in four(4),equally spaced, One or two plies, EasyStick Plus -135.0 at max.24"spans staggered center rows EasyBase TABLE 1D:"WOOD DECKS—NEW CONSTRUCTION or REROOF(Tear-Off) SYSTEM TYPE F: BONDED ROOF COVER System Deck(Note 1) Roof Cover MDP No. Type Joint Treatment Base Ply Ply Cap (pso W-13. Min.15/32"plywood None (Optional)O EasyBase at max.24"spans { P ) Y Base (Optional)EasyBase EasyStick Plus -75.0 W-14. Min.15/32"plywood Plywood joints are covered with 4-inch wide strips of EasyBase,rolled into O EasyBase (Optional)EasyBase EasyStick Plus -120.0 at max.24"spans place to create continuous bond. (Optional)) y ( ) Y Exterior Research and Design,U.C.d/b/a Trinity IERD Evaluation Report T39820.12.11-R3 for FL9487-RS Certificate of Authorization#9503 , 6'EDITION(2017)FBC NON-HVHZ EVALUATION Revision 3:10/02/2017 Prepared by: Robert Nieminen,PE-59166 LeakBarrier®EasyStick-Modified Bitumen Roof Systems;(254)913-7750 Appendix 1,Page 3 of 3