Loading...
HomeMy WebLinkAboutMACKEY - PERMIT DOCUMENTSAll APP ICBLE IlhJF0 MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: +i/IW' Permit Number: Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial PERMIT TYPE: Address: Property Tax ID #: Site Plan Name: Project Name: —' Additional work to be performed under this permit— check all that apply: Mechanical XGas Tank X Gas Piping _ Shutters Residential Electric _ Plumbing _ Sprinklers _ Generator Total Sq. Ft of Construction: Sq. Ft. of First Floor: _ Cost of Construction: $ �� C) Utilities: _Sewer _Septic City: -�- Yiecca State: FL -- Zip Code:13u n Fax: Phone No. E-Mail: Fill in fee simple Title Holder on next page ( if different from the Owner listed above) Name: Larry Licastri Lot No.s Block No. -Windows/Doors Roof Pitch Building Height: Company:AmeriGas Address:3301 Oleander Avenue City: Fort Pierce State: FL Zip Code: 34982 Fax: 772-465-8448 Phnna Nn772-633-0740 E-Ma i I AmeriGas-7262@amerigas.com State or County License02707/28579 f value of construction is $2500 or more, a RECORDED Notice of Commencement is required. If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required. DESIGNER/ENGINEER: _ Not Applicable MORTGAGE COMPANY: _ Not Applicable Name: Name: Address: Address: City: State: _ City: State: Zip: Phone Zip: Phone: FEE SIMPLE TITLE HOLDER: _ Not Applicable BONDING COMPANY: _Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as moicatea. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for impr rt�elits t ur property. A Notice of Commencemen t be re and posted on the jobsite bef re the fi t inspec ' n. If you intend to obtain financi , consu lender r an attorney before ature of o /License Holder ee/Contractor as Agent for Owner Signa%EO=R STAIDA S TE OF LORIDA COUNTY OF V.'z31 CO F St�� The forgoing instrum nt was acknowledged before me this t5 day of :�r • 2QM)C) by The forgoing instrument was acknowledged before me this 1.5 day off.. 20 by \ Name of person making statement Name of person making statement Personally Known 74.OR Produced Identification Personally Known _�—OR Produced Identification Type of Identification Type of Identification Produced Produced ofary Pub"0'9tate of Florida FAON Notary Public State of Florida M Boore Angela M BooreAngela My Commission GG 1s000gMy :Z Commission GG 190609 Expires 02127/2022 (Signature of Notary Publi ". F igna Notary Pu c Commission No26j!3c 1 (Seal) Commission Ncga'- (Seal) REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED Rev. 8/2/17 BOARD OF COUNTY COMMISSIONERS PLANNING & DEVELOPMENT SERVICES DEPARTMENT Building and Code Regulation Division GAS PIPING SCHEMATIC TANK SIZE: GALS. APPLI ANCE — TYPE/SIZE Al A2 A3 A4 A5 A6 PIPING LENGTH & SIZE L1 FT.INCH DIA. 1_2 FT. INCH DIA: 1_3 FT. INCH DIA. L4 FT. INCH DIA. L5 FT. INCH DIA. L6 FT. INCH DIA. 0 FT. INCH DIA. L8 FT. INCH DIA. L9 FT. INCH DIA. L10 FT. INCH DIA. L11 FT. INCH DIA. L12 FT. INCH DIA. Revised 7/22114 BTU BTU BTU BTU BTU (PIPE SIZE WAS TAKEN FROM THE2014 FBCFUEL GAS CODE - TABLE 402 (_J) Website: www stlucieco aov 2300 Virginia Avenue - Fort Pierce. FL. 34982-5652 Phone (772) 462-1553 FAX (772) 462-1578 Designed m reduce first singe Pns of 5 to 20 PSIG down to burner pressure, namral(y w.G Ideal for medium commercial installations, multiple cylinder installations and normal domestic loads- reabo Large vent helps -prevent blockage and has w" FNPT for vent piping. With 15 PSIG inlet pressure, regulator is designed to, not pass Mora than 2 PSfG vvM the seat disc removed. Incurporetes inle9rai relief calves. _ Reptsceable valve oriffee and valve seat disc. Straight line valve closure reduces wear on seat disc. Unique -bonnet vent profile minimizes vent freeze over when property installed. Large molded diaphragm is e,&a sensitive to pressure changes. Built in pressure tap has plugged 1/8" FNPT outlet Plug can be removed with a 3/18" hex allen wrench. Select brown finish. e Mounts directly to house I'Me piping. Eliminates need for union joints, elbows, and mounting brackets. Quick and easy to install. LV4403B 3%" t v4TW4 I ,,, .. Die Ca ,, ...._.__....._..._....,.,..._._..-.. Die Cad Zane at le ......_. Orfice........_-._.._....._.......Brass s ItCisc........ Fabric and Synthefre Rubber. Diaphragm Diapfiragm ._-.._.__------- . Integtaled 0440339eake LV4403BR E 14s %i' FNPTTwcat 10 PSIG.'28DillInlet"Eo3"wcOver Inlet R° %" F NPTfifiR` '6aclonaunt daslgn Maximum Ilnwhesed on 16 PSIG Inlet and 9" w.e tletivery p,sssure. qqCC IDO Rege nr. P.O. Box 24T KC 2T2441150. xm¢regopmduaL,.com Phone Mal Fax(3361 US-M4> dila� Application Materials ideal for use as a *at stage regulator on any domestic size ASME or DOT container in piopane gas installations requiring UP to 1,500,000 BTU's per hour. The regulator is factory set to reduce container pressure to an intermediate pressure of approximately 10 PSIG. Features Compact design can be connected to a service valve using either a POL adapter or a RegO product pigtail. • Large threaded #" P.NPT bonnet vent can easily be piped -away underground installations without the need of glue kits or extra adapters. NonAdjusfsble Large flow orifice resists freeze ups due to water concentration in LPG vapor. Design provides for good flow regulation at both high and law container pressures. Built in relief valve and travel stop comply with NFPA 58 over pressure requirements. incorporates ENPT downstream pressure cap for an easy inline check of the regulator's delivery pressure. Molded diaphragm provides an o-dog type seat between the body and bonnet Body and bonnet are assembled in the USA using the unique, Selected RegWok seal system. Fully painted in brilliant red For complete corrosion protection. Mounting bracket available as an accessory: part number 2302-31. 3.Sfi" Ordering information W' FNPT ...........................................'--._ Body._ ......................_.. .............Zinc .......Steel Seat Disc --- ............�.� .... d_rated Fabric and Resdie c R Rubber ber Diaphragm ............ ........._ teg Lamm,. Ma" %" F.NPT I %a" I 40 PSIG FLOW PROPANE 1,500,000 uaa,aoo LV3403TR40 j 20% ha.., than Ns setting. u Maximm flow based anniet pressure 20 PSIG higher than the regulaar satung and delwen' pressure 2a%ram, thute, regUIROut.Ott amaea nv araeasaU A 94 00 Rego Or. P.O. Be. 24T Elan, NC 27244 USA www.regopmducs.com thee (936) 99-TIo] Fax t336t Lade-6594 y. CABLE W/ ;LAMPS TO (PULLED ANCHOR STRAP (2) LAYERS OF FELT BETWEEN STRAP AND CLAMPS TO (PULLED - UNDERGROUND TANK HOLD DOWN DETAIL SHOWN AELOW. ANCHORS SHALL BE INSTALLED PER GENERAL NOTES: ALLOWABLE PULL-OUT CAPACITY. AS ANCHOR CAPACITY WITH _AL NHOR a H ACHIEVE STATED LOAD CAPACITY- GAPACITY VARIES WITH SOIL TYPE. VERIFY HFJJCAL ANCHORS SHALL HAVE AN IJ )0%,:-4NN 6A�- TANK ,.. 660# CODES AND Is THE IO CAL TvN _ . - 350k, IES PRIOR STRUCTURES ANCHOR AND FEATURES ARE DEPE90ENT UPON LOCAL CHECK F TANKGROLAATNIV Z0 ADJACENT SE LOCATION 0- C-S�.ONSIBILTTY OF OTHERS. _ �. ', TNErTANK .AS SHOWN HAS- BEEN DESIGNED TO PREVENT FLOTATION, COLLAPSE, �A LATERAL MOVEMENT DURING THE BA L000,.,EVENT CDPYWGHT 2016 — FARLEY ENGINEERING LLC r\LL 1 ` ,— 40115 — CA2B1D8 -_ Cansultin9 En9lneer -- QA Quality Steel Corporation AG/UG Propane Tanks �rec wmrn 1+ �0 i:ry. Able U� PPROXIMATE ABOVEGROUND/UNDEGROUND (AG/UG) VESSEL DIMENSIONS AND SPECIFICATIONS h WATER CAPACITY DIAMETER (OD) HEAD TYPE OVERALL LENGTH OVERALL HEIGHT . LEG* WIDTH LEG** SPACING WEIGHT (lbs.) **QUANTITY FULLLOAD PERSTACK *120w9. 24" Ellip. 5'-8" 3' 1'-11/2° 2'-10W" orY11" 260 108 196 16 112 *250 wg. 30" Hemi. V-10" 3'-8" 1'-5" 4-41" 480 54 9 *320wg. 30" Hemi. 9'-7" 3'-8" 1'-5" 5' 620 45 9 500 wg. 1000wg. 371/2" 41" Hemi. Hemi. 10' 16' 4'-2" 4'-5" 1'-8" 1'-8" S' 10'1" 950 1,800 37 1 30 17115 8 1 6 615 1450wg. 461/2" Ellip. 17'-4" 4'-11" 1'-9" 11'7" 2,650 12 4 1990 wg. 461/2" Ellip, 23'-11" 4'-11" 1'-9" 16' 3,520 8 4 Dimensions and specifications shown are approximate, Individual vessels may vary. °Legspacing+/-2". Leg widths and spacing may vary based on mfg.location. Check with your salespasan for details. 120, 250,320 wg,. standard tanks no holes in legs (one center hole on request). 500 and 1000 wg. standard tanks- 2 holes 16" on center. 145o wg. and up as shown above. «' Full load and stack quantities vary by shipping location. Check with your salesperson for details. General Specifications Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section Vill, Division 1. Complies with NFPA S8. -Rated at Z50 psig from -20" F to 125° F. All vessels registered with National Board. - Two service options available: Option 1: Ready -to -bury underground option, coated with either powder coated phenolic epoxy finish or liquid applied epoxy primer coat followed by urethane top coat, supplied with composite AG/UG dome. Option 2: Aboveground option, coated with either powder coated TGIC polyester finish or liquid applied epoxy primer coat followed by urethane topcoat, supplied with steel AG/UG dome. - All vessels are shipped vacuum pre -purged to enable simplified first fill of the vessel. Updated June 30, 2015 Chapter 15 - Plpe and Tubing SIzing Tables 1� Seen Ffrat Stage m d SeemLd Stage EARLTs 151(0) Polyethylene p1wric Pipe 31 Regulators: Nominal Outside Diameter (IP4 Gas: Und watiPropone lnktPrsaure: IAOpai PnawDrop: I.Opst 1pseifrc Grob. L52 plastid Pipe 4in 'fain 1m 1%in. SDR30,00 Iff/in SDRIL00 2ue. SDRIL00 Length S➢R9.33 S))HILO S➢R194 (1.328) (1,554) (1•943) (g) (0.660) (0.860) (1.071 _ 130 2143 4292 7744 1.1416 11482 20260 17340 36402 31155 40 1835 3673 6628 1Ot16 15�68 27612 50 1626 3256 5874 5322 9220 13924 25019 60 70 1473 1355 2950 2714 4896 8483 12810 23017 80 1261 2525 4555 7891 7404 11918 11182 21413 26091 90 1183 1117 2369 2238 4274 4037 6994 10562 18978 100 125 990 1983 3578 6199 9361 9492 16820 15240 150 897 1797 3242 .5616 175 826 1653 2993 5167 1T9 20 1043 �a--77s---- 1539 --.- 5.. 2603 m n0 4510 6811 _. 2238 11560 225 721 691 144.1 1363 2459 4260 64_14 11560 250 275 646 1294 2336 4046 6111 10979 300 617 s 1235 2228 3860 5830 10474 9636 350 567 1136 2050 I907 3551 3304 5363 4989 8965 400 528 528 1057 992 1789 3100 4681 9411 450 500 468 937 1690 2928 4422 7945 600 424 849 1531 2653 4007 7199 6623 760 390 781 726 1409 1311 2441 2271 3686 3429 6161 363 3 682 1230 2131 3217 5781 90000 1000 322 644 1162 2012 3039 5461 1500 258 517 933 1616 2441 4395 2000 221. 443 799 1383 2089 3753 IYS; Iran pipe size. SDR; Stud rd dimension ratio. - - Notes; (1) CapaeiLies are in 1000 $Ln16C (21 Dimensions in parenL6eses are inside diameter- 2014 LP --Gas Code Handbook Bk 11 M will Kll� Em