HomeMy WebLinkAboutHealth Department Septic Approval APPLICATION #:AP1408687
STATE OF FLORIDA PERMIT #:56-SF-1940854
DEPARMONT OF HEALTH DOCUMENT #:FI 1431837
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
'A CONSTRUCTION INSPECTION AND •FINAL APPROVAL DATE PAID:
04/12/2019
- FEE PAID:
515.00
RECEIPT #:56-PID-3901353
APPLICANT: Wade Joumey.Home
AGENT: Wade Jurney Homes,LLC
PROPERTY ADDREss: 5305 Hummingbird Way Fort,Pierce, FL 34951
LOT: 15 BLOCK: 12
SUBDIVISION: Lakewood Park ID#: 1301-602-0041.000-4
'CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND 'MUST BE CORRECTED.
TANK INSTALLATION SETBACKS
[' ] [01] TANK-SIZE [1] 1050.00 [2'] 300.00 [ 1 [27] SURFACE WATER FT
[ ] [02] TANK MATERIAL Concrete [ ] [28] DITCHES FT
[ l [03] 'OUTLET DEVICE [ ] [29] PRIVATE WELLS 100 FT
[ .] [04] MULTI-CHAMBERED [LZJ N ] [ ] [30] PUBLIC WELLS FT
[ 1 [05] OUTLET FILTER• Polylok PL-68 [ ] [31] - IRRIGATION WELLS FT
[ ] [06] LEGEND 1. 28;015-03DC4. 2. 70-156-03SC3 [ 1 [32] POTABLE WATER 21 FT
[ ] [07] WATERTIGHT [ 1 [33] BUILDING' FOUNDATIONS 5 FT
[ ] [081 LEVEL [ 1 [34] PROPERTY LINES 5 FT
[ ] [09] DEPTH TO LID [ ] [35] 'OTHER' FT
DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM
[ ] [10]' AREA [1] 510 '[2] SQFT [ ] [36]. DRAINFIELD COVER
[ ] [11] DISTRIBUTION BOX HEADER X [ 1 [37] SHOULDERS
[ ] [12] NUMBER OF DRAINLINES 1. 5.00 2. [ 1 [38] SLOPES
[ ] [13] DRAINLINE SEPARATION [ ] [39] STABILIZATION 06/05/2020
[ ] [14] DRAINLINE SLOPE
[ ] [15] DEPTH OF COVER ADDITIONAL INFORMATION
[ ] [16] ELEVATION '[ ABOVE / BELOW ]BM 1.00 [ ] [4'0] UNOBSTRUCTED AREA
[ 1 [17] SYSTEM LOCATION [ ] [41] STORMWATER RUNOFF
[ • ] [18] DOSING PUMPS 1.00 [ 1 [42] ALARMS
[ ] [19] AGGREGATE SIZE [ 1 [43] MAINTENANCE AGREEMENT
[ 7 [20] AGGREGATE EXCESSIVE FINES [ 1 [44.] BUILDING AREA
[ 1 [21] AGGREGATE ,DEPTH [ ] [45] LOCATION CONFORMS WITH SITE,PLAN
- FILL / EXCAVATION MATERIAL [' l [46] FINAL SITE GRADING
[ ] [22] FILL AMOUNT [, 1 [4.71 CONTRACTOR Bruce T Mc Cullers(Reliable T
] [23] FILL TEXTURE [ ] [48] OTHER ADS MPS-9(9 pipes-2 tier)
[ ] [24] EXCAVATION DEPTH ABANDONMENT
[ 1 [25] AREA REPLACED [ ] [49] TANK PUMPED
[ 1 [26] REPLACEMENT MATERIAL I ] [50] TANK CRUSHED & FILLED
Comments; Comments are on,page 2.
CONSTRUCTION [ APPROVED / St. Lucie CHD DATE: 04/20/2020
DISAPPROVED l° EnVITni ental Specialist an J Ingram(ENVIRONMENTAL HEALTH)
FINAL SYSTEM ( APPROVED / ,DISAPPROVED' 3: St.Lucie CHD DATE: 06/05/2020
nv ronmental Specialist rian J Ingram(ENVIRONMENTAL HEALTH)
(Explanation of Violations on following page)
DH 4016, 08/09 (Obsoletes all previous editions which,ma not be used)
Incorporated: 64E-.6.003, FAC Page 2 of, 3
EH Database v 1.0.1 AP1408687 EID194o864
APPLICATION #aAP1408687
STATE OF FLORIDA PERMIT #:56—SF-1940854.
DEPARTMENT OF HEALTH DOCUMENT #:F1,1431837,
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAm:04/12/2019
FEE PAID:51'5.00
RECEIPT #:56—PID-3901353
Molation Number. Comment
Comments
The;system is sized for bedrooms with a maximum occupancy of 8 persons(2 per,bedroom),for a total estimated flow of 400
gpd•
New ST,filter,DT;bames 1/3 hp pu'rtlp,and 4x35'+1x30'TRENCH DF installed. No violations,system ok to cover. Contractor
notified by phone. Needs final inspection for mound system,gutter,alarm check,and final site grading. Alarm not completely
installed at construction inspection.Verify that pump/float wires exit DT riser in conduit.Well inspected at construction.inspection.
Final system approved. Contractor and building department emailed final approval..
DH 4016, 08/09 (Obsoletes all previous editions"which may not be used)
Incorporated: 64E-6..003, FAC - Page 2 of' 3'
EH Database v 1.0.1 AP1408687 EID1940854