HomeMy WebLinkAboutInspection ReportDecember 23, 2008 Permit # 0810-0190 ST. LUCIE COUNTY PUBLIC WORKS DEPARTMENT CODE COMPLIANCE DIVISION 2300 Virginia Avenue Fort Pierce, Florida 34982-M2 U. GERLEY A QSSOCUQTES STRUCTURAL ENGONEEGB 3190 N.E. MAPLE AVE JENSEN BEACH, FLORIDA 34957 TEL 772 334-2600 FAX 772 334-2603 INSPECTION REPORT NO.01 PROJECT: Turtle Reef Club Condominium II 2008 Building "C" Concrete Repairs LOCATION: 10800 South Ocean Drive Jensen Beach, Florida 34957 CONTRACTOR: Daniello Construction, Inc., CGC #020612 AREA INSPECTED: Repairs #1 (B&C), 2, 3, 4, 5, 6, 7, 8, 9, 10, & 14B (per Project Drawing S1) • Excavation of unsound concrete limits ven/ied • Exposed reinforcing verified sandblasted to bright metal Exposed reinforcing verified coated with anti-cor►osiorYbonding agent INSPECTION DATE: December 15t', 2008 FINDINGS: Activities are satisfactory (see photographs, page 2) COMMENTS: 1) Additional damage uncovered at #1, upper & lower column, noted as 'IT & 'C' (see photos) 2) Additional damage uncovered at Stucco Repair #47, noted as "14B° (see photos) 3) All repairs this Inspection Report utilized Sika Armatec 110 Epocem anti- corrosion/bonding agent and BASF LA40 Repair Mortar Sincerely, V.J.GERLEY D ASSOCIATES �"La-ter r�^r-�•-` Certified: Victor J.G dey, PE I Field Coordination: Scott A. Lorraine, PE Florida Spec.lnsp. #11, 9, Prof.Engr. #21422 Florida Prof.Engr. #38714 distrib: Charlie Andrews Gen. Mgr., Turtle Reef Club (via email) Victor J. Gedey, PE V.J.Geriey & Assoc. (Project file; via email) Scott A. Lorraine, PE Scott A. Lorraine, PE, LLC (Project file) 1 Note - ...:..os are for representative purposes only as noted h., i ions I }rd "7 Additional upper repair "W at Col. D1 (initial cut-out to bonded reinforcing) Repair#1 as designated Additional lower repair'1C"atCol. D1 (final cut-out, cleaned & coated) (initial cut-out to bonded reinforcing) Non -Structural Stucco Repair #47 upgraded to Structural Column Repairs #8 & #9 with Beam Repair #1 D Repair #"14B" (final cut-out cleaned & coated) (all to final cut-out, cleaned & coated, with #8 being fom►ed) N i December 23, 2008 Pemnit # 0810-0190 ST. LUCIE COUNTY PUBLIC WORKS DEPARTMENT CODE COMPLIANCE DIVISION 2300 Virginia Avenue Fort Pierce, Florida 34982-5632 U. GERLEY'A ASSOCIATES 3190 N.E. MAPLE AVE JENSEN BEACH,FLORIDA 34957 TEL 772 334-2600 FAX 772 334-2603 INSPECTION REPORT NO.02 PROJECT: Turtle Reef Club Condominium 11 2008 Building "C" Concrete Repairs LOCATION: 10800 South Ocean Drive Jensen Beach, Florida 34957 CONTRACTOR: Daniello Construction, Inc., CGC #020612 AREA INSPECTED: Repairs #23, 31(B), 348, 37(B), 39 & 44B (per Project Drawings S1& S2) • Excavation of unsound concrete limits verified • Exposed ninforcing verified sandblasted to bright metal • Exposed n inibming verified coated with anti-corrosion/bonding agent INSPECTION DATE: December 180', 2008 FINDINGS: Activities are satisfactory COMMENTS: 1) Additional damage uncovered at retaining wall (see photos, page 2): • Unit 110 — Repair #31 B • Unit 109 — Repair #34B • Unit 108 — Repair #37B • Unit 105 — Repair#44B 3) All repairs this Inspection Report utilized BASF Emaco P24 anti- corrosion/bonding agent and BASF LA40 or HBA Repair Mortar Sincerely, V.J.GERL Y A D ASSOCIATES Gd-t-1 Certified: Victor J. edey, PE I Field Coordination: Scott A. Lorraine, PE Florida Spec.lnsp. 9, Prof.Engr. #21422 Florida Prof.Engr. #38714 distrib: Charlie Andrews Gen. Mgr., Turtle Reef Club (via email) Victor J. Gedey, PE V.J.Gedey & Assoc. (Project file; via email) Scott A. Lorraine, PE Scott A. Lorraine, PE, LLC (Project file) 1 Note tos are for representative purposes only as noted ii `ions ems`-�'` .- �� •;' � `� a � I•-b ... x �` a fey. Additional damage (#31B) at Unit #110 retaining wall adjacent to repair#31 per Project Drawing S2 Additional damage (#37B) at Unit #108 retaining wall adjacent to repair #37 per Project Drawing S2 Additional damage (#34B) at Unit #109 retaining wall adjacent to repair #34 (wing wall) per Project Drawing S2 #37B eont d (note new #4 horiz bar) columnK41fetaining wall adjacent to repair #37 per Project Drawing S2 Additional damage (#44B) at Unit #105 retaining wall adjacent to repair #44 (wing walq per Project Drawing S2 (column at right is E4). Cut-out is through laundry room at garage level. N December 23, 2008 Permit # 0810-0190 ST. LUCIE COUNTY PUBLIC WORKS DEPARTMENT CODE COMPLIANCE DIVISION 2300 Virginia Avenue Fort Pierce, Florida 34982-5632 W.J. GERLE 11 0 WSSOCHW II ES STRUCTURAL ENGIMEERS 3190 N.E. MAPLE AVE JENSEN BEACH, FLORIDA 34957 TEL 772 334-2600 FAX 772 334-2603 INSPECTION REPORT NO.03 PROJECT: Turtle Reef Club Condominium II 2008 Building "C" Concrete Repairs LOCATION: 10800 South Ocean Drive Jensen Beach, Florida 34957 CONTRACTOR: Daniello Construction, Inc., CGC #020612 AREA INSPECTED: Repair; #1(1B), 2(2B), 3, 4(4B), 5, 6, 7, 8, 9, 10(10B), & 14B (per Project Drawing S1) • Satisfactory formwork to repair limits verified • Satisfactory repair mortar patchinglp/acement after form removal verified • Repair area deemed acceptable for stucco repair (shoring removed) INSPECTION DATE: December 1e, 2008 FINDINGS: Activities are satisfactory COMMENTS: [See photos] 1) Additional repair at #1 (IR#1), upper & lower column, noted as "B" & "C" 2) Additional repair at #2, opposite beam face, noted as "26" 3) Additional repair at #4, mid column / opposite face, noted as W" 4) Additional repair at #10, beam spall continuation at column, noted as "I OW 5) Additional repair at stucco #47, lower column A, noted as "146" 6) All repairs this Inspection Report utilized BASF Emaco P24 anti- corrosion/bonding agent and BASF LA40 Repair Mortar Sincerely, V.J.GERL14\Y AND ASSOCIATES Certified: VctJ.Gefley, PE Florida Spec.l Sp. #89, Prof.Engr. #21422 'CI• ( e"-� J �� Field Coordination: Scott A. Lorraine, PE Florida Prof.Engr. #38714 distrib: Charlie Andrews Gen. Mgr., Turtle Reef Club (via email) Victor J. Gerley, PE V.J.Ge►tey & Assoc. (Project file; via email) Scott A. Lorraine, PE Scott A. Lorraine, PE, LLC (Project file) 1 Note .:tos are for representative purposes only as noted 'i : —;pions Repair#1, #1B, & #iC Repair #10B Repair #4B Repair #2B (small spall to be repaired by cleaning & patching with BASF HBA) Repair #14B .2 r-= A Y.J. GERL Y o ASSOCIATES STRUCTURAL EMONEERS 3190 N.E. MAPLE AVE JENSEN BEACH, FLORIDA 34957 TEL 772 334-2600 FAX 772 334-2603 January 16, 2009 Permit # 0810-0190 ST. LUCIE COUNTY PUBLIC WORKS DEPARTMENT CODE COMPLIANCE DIVISION 2300 Virginia Avenue Fort Pierce, Florida 34982-5632 INSPECTION REPORT NO.04 PROJECT: Turtle Reef Club Condominium II 2008 Building "C" Concrete Repairs LOCATION: 10800 South Ocean Drive Jensen Beach, Florida 34957 CONTRACTOR: Daniello Construction, Inc., CGC #020612 AREA INSPECTED: Repairs #313, 11(B), 12, 14, 16, 17, 18, 21C, 21D, 27, 28, 29, 29B, 34C, 35, 36, 38, 39, 40, 41, 41 B, 42, 43, & 44 (per Project Drawings S1& S2 - Supplemental Repairs denoted w/ suffix'B', 'C', etc.) • Excavation of unsound concrete limits verified • Exposed reinforcing verified sandblasted to bright metal • Exposed reinforcing verified coated with anti-cofrosionlbonding agent INSPECTION DATE: January e, 2008 FINDINGS: Activities are satisfactory COMMENTS: 1) Additional damage uncovered at columns, beam, BJor retaining wall (see photos, page 2) 2) All repairs this Inspection Report utilized BASF Emaco P24 anti- corrosion/bonding agent and BASF LA40 or HBA Repair Mortar 3) Project drawings will be revised at Projects end to reflect "as -repaired" conditions including supplemental repairs as noted herein Sincerely, V.J.GEMEY AND ASSOCIATES V� Certified: Florida Sm J.Gedey, IPE ;p. #89, P of.Engr. #21422 Field Coordination: Scott A. Lorraine, PE Florida Prof.Engr. #38714 distrib: Charlie Andrews Gen.Mgr., Turtle Reef Club (via email) Victor J. Gerley, PE V.J.Gerley & Assoc. (Project file; via email) Scott A. Lorraine, PE Scott A. Lorraine, PE, LLC (Project file) 1 —^F Inspection Report #4 — Photos are for representative purposes only as noted in captions Supplemental Repair #38 — beam at Col.Une 'D' Supplemental Repair #118 — Col H2 Supplemental Repair #298 — Unit 110 I STRUCTURAL EYVGINEERS 3190 N.E. MAPLE AVE JENSEN BEACH, FLORIDA 34957 TEL 772 334-2600 FAX 772 334-2603 January 16, 2009 Permit # 0810-0190 ST. LUCIE COUNTY PUBLIC WORKS DEPARTMENT CODE COMPLIANCE DIVISION 2300 Virginia Avenue Fort Pierce, Florida 34982-5632 INSPECTION REPORT NO.05 PROJECT: Turtle Reef Club Condominium II 2008 Building "C" Concrete Repairs LOCATION: 10800 South Ocean Drive • Jensen Beach, Florida 34957 CONTRACTOR: Daniello Construction, Inc., CGC #020612 AREA INSPECTED: Repairs #1C, 313, 11(B),12,14, 16, 17, 18, 21C, 21D, 23, 27, 28, 30, 31(B), 32, 33, 34(B&C), 35, 36, 37(B), 38, 39, 40, 41(B), 42, 43, & 44B (per Project Drawings S1& S2 - Supplemental Repairs denoted w/ sutiix'B', 'C', etc.) • Satisfactory formwork to repair limits vertfled • Satisfactory repair mortar patching/placement after form removal verified • Repair area deemed acceptable for stucco repair (shoring removed) INSPECTION DATE: January e, 2009 FINDINGS: Activities are satisfactory COMMENTS: 1) Additional damage uncovered at columns, beam, BJor retaining wall (see photos, page 2) 2) All repairs this Inspection Report utilized BASF Emaco P24 anti- corrosion/bonding agent and BASF LA40 or HBA Repair Mortar as applicable 3) Project drawings will be revised at Projects end to reflect "as -repaired" conditions including supplemental repairs as noted herein Sincerely, VA.GERLEMAND ASSOCIATES Certified: Victor Florida Spec.ln: Geriey, PE I . #89, Prof. ngr. #21422 L�•t f I7'�"��` Field Coordination: Scott A. Lorraine, PE Florida Prof.Engr. #38714 distrib: Charlie Andrews Gen.Mgr., Turtle Reef Club (via email) Victor J. Gerley, PE V.J.Gerley & Assoc. (Project file; via email) Scott A. Lorraine, PE Scott A. Lorraine, PE, LLC (Project file) 1 Inspection Report #5 — Photos are for representative purposes only as noted in captions Col. D1 Col. 03 Supplemental Repair #3B Beam at Col line V Supplemental Repair #31 B retaining wall at Unit 110 Col. H2 retaining wall at Unit 109 Col. 03 Col M4, Unit 109 retaining wall at Unit 108 retaining wall at Unit 106 retaining wall at Unit 105 January 16, 2009 Permit # 0810-0190 ST. LUCIE COUNTY PUBLIC WORKS DEPARTMENT CODE COMPLIANCE DIVISION 2300 Virginia Avenue Fort Pierce, Florida 34982-5632 87RUCIIl1UlAL LSIIVOIfUEERS 3190 N.E. MAPLE AVE JENSEN BEACH, FLORIDA 34957 TEL 772 334-2600 FAX 772 334-2603 INSPECTION REPORT NO.06 PROJECT: Turtle Reef Club Condominium II 2008 Building "C" Concrete Repairs LOCATION: 10800 South Ocean Drive Jensen Beach, Florida 34957 CONTRACTOR: Daniello Construction, Inc., CGC #020612 AREA INSPECTED: Repairs # 12B, 14C, 15,16B, 20, 21(B&E), 22, 24, 25, 26, 29C, 44C-G, 53, & 54 (per Project Drawings S1& S2 - Supplemental Repairs denoted w/ suffoc'B', 'C', etc.) Excavation of unsound concrete limits verified Exposed reinforcing verified sandblasted to bright metal Exposed reinforcing verified coated with anti-corrosion/bonding agent INSPECTION DATE: January le, 2009 FINDINGS: Activities are satisfactory COMMENTS: 1) Additional damage uncovered at columns, beam, &/or retaining wall (see photos, page 2) 2) All repairs this Inspection Report utilized BASF Emaco P24 anti- corrosion/bonding agent and BASF LA40 or HBA Repair Mortar as applicable 3) Project drawings will be revised at Project's end to reflect "as -repaired" conditions including supplemental repairs as noted herein Sincerely, V.J.GERLEM AND ASSOCIATES Certified: Victor k4lFlorida Spec.lnsngr. #21422 distrib: Charlie And ws Gen.Mgr., Turtle Reef Club Victor J. Gerley, PE V.J. Gerfey & Assoc. Scott A. Lorraine, PE Scoff A. Lorraine, PE, LLC Field Coordination: Scott A. Lorraine, PE Florida Prof.Engr. #38714 (via email) (Project file; via email) (Project file) 1 Inspection Report #6 — Photos are for representative purposes only as noted in captions Supplemental repairs #44C, 44D, 44E, 44F, & 44G (left to right), retaining wall Unit 105 February 11t', 2009 Permit # 0810-0190 ST. LUCIE COUNTY PUBLIC WORKS DEPARTMENT CODE COMPLIANCE DIVISION 2300 Virginia Avenue Fort Pierce, Florida 34982-5632 Y.J. IYJSEE�yll��pUL �O�r���A 22WMM(SSMO22��WT'EV SIMUCO URALS 6N WHEERS 3190 N.E. MAPLE AVE JENSEN BEACH, FLORIDA 34957 TEL 772 334-2600 FAX 772 334-2603 INSPECTION REPORT NO.07 pec��oe� FEB 2 3 2009 D PROJECT: Turtle Reef Club Condominium II 2008 Building "C" Concrete Repairs LOCATION: 10800 South Ocean Drive Jensen Beach, Florida 34957 CONTRACTOR: Daniello Construction, Inc., CGC #020612 AREA INSPECTED: Repairs # 12B, 14C, 15, 16B, 20, 21(B&E), 22, 24, 25, 26, 29(B&C), 44C-G, (per Project Drawings S1 & S2 - Supplemental Repairs denoted w/ suffix 'B', 'C', etc.) • Satisfactory formwork to repair limits verified • Satisfactory repair mortar patching(placement after form removal verified • Repair area deemed acceptable for stun o repair (shoring removed) INSPECTION DATE: January 20t', 2009 FINDINGS: Activities are satisfactory COMMENTS: 1) Additional damage uncovered at columns, beam, retaining wall, Wor walkway slab (see photos, page 2) 2) All repairs this Inspection Report utilized BASF LA40, HBA Repair Mortar, or 3500psi ready -mix as applicable 3) Project drawings will be revised at Projects end to reflect "as -repaired" conditions including supplemental repairs as noted herein Sincerely, V.J.GERLINLAND ASSOCIATES Certified: Victor J. erley, PE Florida SDec.InSp #89. Prof.Enar #21422 distrib: Charlie Andrews Gen. Mgr., Turtle Reef Club Victor J. Gerley, PE V.J.Gerley & Assoc. Scott A. Lorraine, PE Scoff A. Lorraine, PE, LLC Field Coordination: Scott A. Lorraine, PE Florida Prof.Engr. #38714 (via email) (Project file; via email) (Project file) 1 Inspection Report #7 — Photos are for representative purposes only as noted in captions Supplemental Repair#14C (Col 12) Supplemental Repair #218 (slab at Col 01) Supplemental Repair #29C (Col P4) Supplemental Repairs #44C-G (Unit 105 Ret Wall) February 11d', 2009 Permit # 0810-0190 ST. LUCIE COUNTY PUBLIC WORKS DEPARTMENT CODE COMPLIANCE DIVISION 2300 Virginia Avenue Fort Pierce, Florida 34982-5632 l . (`cW�S�Effo��Il��pLL(�L�rSE��ppO�fo� �Ap �f{ASSOrr���ffoo���ATES � 37RUCTUU1AL, EINGIII�IEERS 3190 N.E. MAPLE AVE JENSEN BEACH, FLORIDA 34957 TEL 772 334-2600 FAX 772 334-2603 INSPECTION REPORT NO.08 PROJECT: Turtle Reef Club Condominium II 2008 Building "C" Concrete Repairs LOCATION: 10800 South Ocean Drive Jensen Beach, Florida 34957 CONTRACTOR: Daniello Construction, Inc., CGC #020612 AREA INSPECTED: Repairs # 1D, 3C&D, 12C, 20B, 29D, 46, 47, 48, 52(B), 78, 79,102 (per Project Drawings S1& S2 - Supplemental Repairs denoted w/ suf ix'B', 'C', etc.) • Excavation of unsound concrete limits verified • Exposed reinforcing verified sandblasted to bright metal • Exposed reinforcing venfred coated with anti-corrosionlbonding agent INSPECTION DATE: January 23`d, 2009 FINDINGS: Activities are satisfactory COMMENTS: 1) Additional damage uncovered at columns, beams, retaining wall Wor walkway slab (see photos, page 2) 2) All repairs this Inspection Report utilized BASF Emaco P24 anti- corrosion/bonding agent 3) Project drawings will be revised at Project's end to reflect "as -repaired" conditions including supplemental repairs as noted herein Sincerely, V.J.GEgLEY AND ASSOCIATES Certified: Victor. .Gerley, PE Florida Spec.lns . #89, Prof.En r. #21422 distrib: Charlie Andrews Gen Mgr, Turtle Reef Club Victor J. Gerley, PE V.J. Gerfey & Assoc. Scott A. Lorraine, PE Scott A. Lorraine, PE, LLC rim Field Coordination: Scott A. Lorraine, PE Florida Prof.Engr. #38714 (via email) (Project file; via email) (Project file) 1 Inspection Re , , M — Photos are for representative purposes only a- _. -�d in captions •r-Ur 1 ���.1 Supplemental repair #3C (slab/beam at Supplemental repair #1 Line D) -. I (underside, left & upper surface, right) Supplemental repair#208 (stairwell column) Supplemental repair #528 (stairwell column, 14 floor) February 11 d', 2009 Permit # 0810-0190 ST. LUCIE COUNTY PUBLIC WORKS DEPARTMENT CODE COMPLIANCE DIVISION 2300 Virginia Avenue Fort Pierce, Florida 34982-5632 W.J. GERLEY o ASSOCHAT S STRUCTURAL ENNN ERE 3190 N.E. MAPLE AVE JENSEN BEACH, FLORIDA 34957 TEL 772 334-2600 FAX 772 334-2603 INSPECTION REPORT NO.09 CE 0 FEB 2 3 2009 PROJECT: Turtle Reef Club Condominium II 2008 Building "C" Concrete Repairs LOCATION: 10800 South Ocean Drive Jensen Beach, Florida 34957 CONTRACTOR: Daniello Construction, Inc., CGC #020612 AREA INSPECTED: Repairs # 3C&D,12C, 20B, 29D, 46, 47, 48, 52, 52B, 78, 79, & 102 (per Project Drawings S1 & S2 - Supplemental Repairs denoted w/ suffix '13% 'C', etc.) • Satisfactory formwork to repair limits verified • Satisfactory repair mortar patching/placement after form removal verified • Repair area deemed acceptable for stucco repair (shoring removed) INSPECTION DATE: February 2"d, 2009 FINDINGS: Activities are satisfactory COMMENTS: 1) Additional damage uncovered at columns, beam, retaining wall, &/or walkway slab (see photos, page 2) 2) All repairs this Inspection Report utilized BASF LA40, HBA Repair Mortar, or 3500psi ready -mix as applicable 3) Project drawings will be revised at Project's end to reflect "as -repaired" conditions including supplemental repairs as noted herein Sincerely, V.J.GERL A ASSOCIATES Certified: Victor-J.Ge iey, PE Field Coordination: Scott A. Lorraine, PE Florida Spec.lnsp. 9, Prof.Eng #21422 Florida Prof.Engr. #38714 distrib: Charlie Andrews Gen Mgr, Turtle Reef Club (via email) Victor J. Gerley, PE V.J.Gerley & Assoc. (Project file; via email) Scott A. Lorraine, PE Scott A. Lorraine, PE, LLC (Project file) 1 Inspection Report #9 — Photos are for representative purposes only as noted in captions Supplemental repairs at grade) Supplemental repair # 29D (overhead -Unit 110 balcony underside) r� April 2e, 2009 Permit # 0810-0190 ` ST. LUCIE COUNTY PUBLIC WORKS DEPARTMENT CODE COMPLIANCE DIVISION 2300 Virginia Avenue Fort Pierce, Florida 34982-5632 W.J. lElLSlA WSSOCOATES U7WUCg1RAti ENGINEERS 3190 N.E. MAPLE AVE JENSEN BEACH, FLORIDA 34957 TEL 772 334-2600 FAX 772 334-2603 0810 - G 6q-D INSPECTION REPORT NO.10 PROJECT: Turtle Reef Club Condominium II 2008 Building "C" Concrete Repairs LOCATION: 10800 South Ocean Drive Jensen Beach, Florida 34957 CONTRACTOR: Daniello Construction, Inc., CGC #020612 AREXINSPECTED: Repairs # 1D&E, 13,15,19, 20C, 27B, 281113, 51B, 54, 55, 57, 58, 6013, 60C, 78B, 78D, 84, 85, 90, & 91 (per Project Drawings S1& S2 - Supplemental Repairs denoted w/ suffx'B', 'C', etc.) • Excavation of unsound concrete limits verified • Exposed reinforcing verified sandblasted to bright metal • Exposed reinforcing verified coated with anti-corrosioMbonding agent INSPECTION DATE: February 25t', 2009 FINDINGS: Activities are satisfactory COMMENTS: 1) Additional damage uncovered at columns, beams, retaining wall Wor walkway slab (see photos, page 2) 2) All repairs this Inspection Report utilized BASF Emaco P24 anti- corrosion/bonding agent 3) Vector Galvashield XP+ sacrificial anodes installed (see Project drawings & specifications) 4) Project drawings will be revised at Project's end to reflect "as -repaired" conditions including supplemental repairs as noted herein -Sincerely, V.J.GERLE' AND ASSOCIATES Id., Certified: Victor 4Gerley, PE Field Coordination: Scott A. Lorraine, PE Florida Spec.lns #89, Prof.Engr. #21422 Florida Prof.Engr. #38714 distrib: Charlie Andrews Gen.Mgr., Turtle Reef Club (via email) Victor J. Gerley, PE V.J.Gedey & Assoc. (Project filel) Scott A. Lorraine, PE Scott A. Lorraine, PE, LLC (Project file) 1 Inspection Report #10 — Photos are for representative purposes only as noted in captions Suppl. repair #20C (Beam at Ocean Suppl. repair# 1E (Column at Garage entrance) (Col. at Ocean Stairs) #78B 2 s) Suppl. Rep. #60C (1 Flr Ocean Stairs) April 28", 2009 Permit # 0810-0190 ST. LUCIE COUNTY PUBLIC WORKS DEPARTMENT CODE COMPLIANCE DIVISION 2300 Virginia Avenue Fort Pierce, Florida 34982-5632 37RUC4MRAd EaMMC ERS 3190 N.E. MAPLE AVE JENSEN BEACH, FLORIDA 34957 TEL 772 334-2600 FAX 772 334-2603 INSPECTION REPORT NO.11 PROJECT: Turtle Reef Club Condominium II 2008 Building "C" Concrete Repairs LOCATION: 10800 South Ocean Drive Jensen Beach, Florida 34957 CONTRACTOR: Daniello Construction, Inc., CGC #020612 AREA INSPECTED: Repairs # 1 DBE, 13,15,19, 20C, 271B, 28B, 51 B, 54, 55, 57, 58, 60B, 60C, 78B, 78D, 84, 85, 90, & 91 (per Project Drawings S1 & S2 - Supplemental Repairs denoted w/ suffix 'B', 'C', etc.) • Satisfactory formwork to repair limits verified • Satisfactory repair mortar patching/placement after form removal verified • Repair area deemed acceptable for stucco repair (shoring removed) INSPECTION DATE: March 6, 2009 FINDINGS: Activities are satisfactory COMMENTS: 1) Additional damage uncovered at columns, beam, retaining wall, Wor walkway slab (see photos, page 2) 2) All repairs this Inspection Report utilized BASF LA40, HBA Repair Mortar, or 3500psi ready -mix as applicable 3) Vector Galvashield XP+ sacrificial anodes installed (see Project drawings & specifications) 4) Project drawings will be revised at Project's end to reflect "as -repaired" conditions including supplemental repairs as noted herein Sincerely, V.J.GER E ND ASSOCIATES '`/• Certified: Victor .Gerley, PE Field Coordination: Scott A. Lorraine, PE Florida Spec.lns . #89, Prof.Engr. #21422 Florida Prof.Engr. #38714 distrib: Charlie Andrews Gen.Mgr., Turtle Reef Club (via email) Victor J. Gerley, PE V.J. Gerley & Assoc. (Project filel) Scott A. Lorraine, PE Scott A. Lorraine, PE, LLC (Project file) 1 Inspection Report #11 — Photos are for representative purposes only as noted in captions SuppL repair #518 Y.J. (GLSnpRp(L5Epp11��pA 2W�I�/S�SM2O��(�ATES STRUCTURAL UUl7AL LSOVl91EIfVEERS 3190 N.E. MAPLE AVE m JENSEN BEACH, FLORIDA 34957 TEL 772 334-2600 FAX 772 334-2603 D April 28 ,Zoos MAY — 5 2009 Permit # 0810-0190 ST. LUCIE COUNTY PUBLIC WORKS DEPARTMENT CODE COMPLIANCE DIVISION 2300 Virginia Avenue Fort Pierce, Florida 34982-5632 INSPECTION REPORT NO.12 PROJECT: Turtle Reef Club Condominium II 2008 Building "C" Concrete Repairs f LOCATION: 10800 South Ocean Drive Jensen Beach,;Florida 34957 CONTRACTOR: Daniello Construction, Inc., CGC #020612 AREA INSPECTED: Repairs # 58B, 60D, 83, 86, 92, 104, 105, 106 (per Project Drawings S2 & S3 - Supplemental Repairs denoted w/ suffix'B', 'C', etc.) • Excavation of unsound concrete limits verified • Exposed reinforcing verified sandblasted to bright metal • Exposed reinforcing verified coated with anti-corrosion/bonding agent INSPECTION DATE: March 18u', 2009 FINDINGS: Activities are satisfactory COMMENTS: 1) Additional damage uncovered at columns, beams, retaining wall &/or walkway slab (see photos, page 2) 2) All repairs this Inspection Report utilized BASF Emaco P24 anti- corrosion/bonding agent 3) Vector Galvashield XP+ sacrificial anodes installed (see Project drawings & specifications) 4) Project drawings will be revised at Projects end to reflect "as -repaired" conditions including supplemental repairs as noted herein Sincerely, V.J.G R Y AND ASSOCIATES N CerRed: Vcto J.Gerley, Florida Spec.l sp. #89, PiTEngr. #21422 distrib: Charlie Andrews Gen.Mgr., Turtle Reef Club (via email) Victor J. Gerley, PE V.J.Gerley & Assoc. (Project file) Scott A. Lorraine, PE Scott A. Lorraine, PE, LLC (Project file) 1 Ld-t� Field Coordination: Scott A. Lorraine, PE Florida Prof.Engr. #38714 April 28, 2009 Permit # 0810-0190 ST. LUCIE COUNTY PUBLIC WORKS DEPARTMENT CODE COMPLIANCE DIVISION 2300 Virginia Avenue Fort Pierce, Florida 34982-5632 W.J. WCRdEASSOCIATESSTRUC5RAL ENGOVEERS 3190 N.E. MAPLE AVE JENSEN BEACH, FLORIDA 34957 TEL 772 334-2600 FAX 772 334-2603 INSPECTION REPORT NO.13 DI� MAY - 5 2009 08-6 -at 9z) PROJECT: Turtle Reef Club Condominium II 2008 Building "C" Concrete Repairs LOCATION: 10800 South Ocean Drive Jensen Beach, Florida 34957 CONTRACTOR: Daniello Construction, Inc., CGC #020612 AREA INSPECTED: Repairs # 58B, 60D, 83, 86, 92, 104,105, 106 (per Project Drawings S1& S2 - Supplemental Repairs denoted w/ suffix'B', 'C', etc.) • Satisfactory formwork to repair limits verified • Satisfactory repair mortar patching/placement after form removal verified • Repair area deemed acceptable for stucco repair (shoring removed) INSPECTION DATE: April le, 2009 FINDINGS: Activities are satisfactory COMMENTS: 1) Additional damage uncovered at columns, beam, retaining wall, &/or walkway slab (see photos, page 2) 2) All repairs this Inspection Report utilized BASF LA40, HBA Repair Mortar, or 3500psi ready -mix as.applicable 3) Vector Galvashield XP+ sacrificial anodes installed (see Project drawings & specifications) 4) Project drawings will be revised at Projects end to reflect "as -repaired" conditions including supplemental repairs as noted herein Sincerely, V.J.GE Y AND ASSOCIATES Certified: Vict r J.Gerley, PE Field Coordination: Scott A. Lorraine, PE Florida Spec.l sp. #89, Prof. ngr. #21422 Florida Prof.Engr. #38714 distrib: Charlie Andrews Gen.Mgr., Turtle Reef Club (via email) Victor J. Gerley, PE V.J.Gerley & Assoc. (Project file) Scott A. Lorraine, PE Scott A. Lorraine, PE, LLC (Project file) 1 Inspection Report #13 — Photos are for representative purposes only as noted in captions June le, 2009 Permit # 0810-0190 ST. LUCIE COUNTY PUBLIC WORKS DEPARTMENT CODE COMPLIANCE DIVISION 2300 Virginia Avenue Fort Pierce, Florida 34982-5632 STRUCTURAL EHROa[ ERE 3190 N.E. MAPLE AVE JENSEN BEACH, FLORIDA 34957 TEL 772 334-2600 FAX 772 334-2603 INSPECTION REPORT.NO.14 PROJECT: Turtle Reef Club Condominium II 2008 Building "C" Concrete Repairs LOCATION: 10800 South Ocean Drive Jensen Beach, Florida 34957 CONTRACTOR: Daniello Construction, Inc., CGC #020612 AREA INSPECTED: Repairs # 32B, 58C, 106(B&C)i 107C (per Project Drawings S3, S4, & S5 - Supplemental Repairs denoted w/ suffix 'B', 'C', etc.) • Excavation of unsound concrete limits verified • Exposed reinforcing verified sandblasted to bright metal, • Exposed reinforcing verified coated with anti-corrosion/bonding agent INSPECTION DATE: May 5t', 2009 FINDINGS: Activities are satisfactory COMMENTS: 1) Additional damage uncovered at columns, beams, retaining wall &/or walkway slab (see photos, page 2) 2) All repairs this Inspection Report utilized BASF Emaco P24 anti- corrosion/bonding agent 3) Vector Galvashield XP+ sacrificial anodes installed (see Project drawings & specifications) 4) Project drawings will be revised at Project's end to reflect "as -repaired" conditions including supplemental repairs as noted herein Sincerely, V.J.GERLEY AND ASSOCIATES Certified: Victor 4.Gerley, PE Florida Spec.lns . #89, Prof.Engr. #21422 distrib: Charlie Andrews Gen. Mgr., Turtle Reef Club (via email) Victor J. Gerley, PE V.J.Gerley & Assoc. (Project file) SaottA. Lorraine, PE Scott A. Lorraine, PE, LLC (Project file) 1 / Latl Field Coordination: Scott A. Lorraine, PE Florida Prof.Engr. #38714 lip* ► Inspection Report #14 — Photos are for representative purposes only as noted in captions Supp. repair #106C (5" level column P1) Suppleme 2 Supp. repair #107C (roof & stairwell column 9110)) imn P4) W.J. 'V/ 3190 N.E. MAPLE AVE JENSEN BEACH, FLORIDA 34957 TEL 772 334-2600 FAX 772 334-2603 June 15t', 2009 Permit # 0810-0190 ST. LUCIE COUNTY PUBLIC WORKS DEPARTMENT CODE COMPLIANCE DIVISION 2300 Virginia Avenue Fort Pierce, Florida 34982-5632 INSPECTION REPORT NO.15 c��oer� PROJECT: Turtle Reef Club Condominium II 2008 Building "C" Concrete Repairs LOCATION: 10800 South Ocean Drive Jensen Beach, Florida 34957 CONTRACTOR: Daniello Construction, Inc., CGC #020612 AREA INSPECTED: Repairs # 32B, 58C,106(B&C),107C (per Project Drawings S3, S4, & S5 - Supplemental Repairs denoted w/ suffix'B', 'C', etc.) • Satisfactory formwork to repair limits verified • Satisfactory repair mortar patching/placement after form removal venBed • Repair area deemed acceptable for stucco repair (shoring removed) INSPECTION DATE: May Ie, 2009 FINDINGS: Activities are satisfactory COMMENTS: 1) Additional damage uncovered at columns, beam, retaining wall, &/orwalkway slab (see photos, page 2) 2) All repairs this Inspection Report utilized BASF LA40, HBA Repair Mortar, or 3500psi ready -mix as applicable 3) Vector Galvashield XP+ sacrificial anodes installed (see Project drawings & specifications) 4) Project drawings will be revised at Projecrs end to reflect "as -repaired" conditions including supplemental repairs as noted herein Sincerely, V.J.GE L AND ASSOCIATES /% err7—..'' r Certified: Vict r J.Gerleyl PE Field Coordination: Scott A. Lorraine, PE Florida Spec. nsp. #89, Prof.Engr. #21422 Florida Prof.Engr. #38714 distrib: Charlie Andrews Gen.Mgr., Turtle Reef Club (via email) Victor J. Gerley, PE V.J.Gerley & Assoc. (Project file) Scott A. Lorraine, PE Scott A. Lorraine, PE, LLC (Project file) 1 Inspection Report #15 — Photos are for representative purposes only as noted in captions Su, S Al Supp. repair #107C (underside stairwell roof & column 9110) June 15t', 2009 Permit # 0810-0190 ST. LUCIE COUNTY PUBLIC WORKS DEPARTMENT CODE COMPLIANCE DIVISION 2300 Virginia Avenue Fort Pierce, Florida 34982-5632 W.J. GERLE r A ASSOMATES CE G G D NI STRUCTURAL EMONEERS p JENSEN BEACH,FFLORIDAE34957 J U N 1 9 2009 TEL 772 334-2600 FAX 772 334-2603 INSPECTION REPORT NO.16 PROJECT: Turtle Reef Club Condominium II 2008 Building "C" Concrete Repairs LOCATION: 10800 South Ocean Drive Jensen Beach, Florida 34957 CONTRACTOR: Daniello Construction, Inc., CGC #020612 AREA INSPECTED: Repairs # 32C, 6013, 107B,108,108B (per Project Drawings S4, S5, & S6 - Supplemental Repairs denoted w/ suftbc 'B', 'C', etc.) • Excavation of unsound concrete limits verified • Exposed reinforcing verified sandblasted to bright metal • Exposed ►einfoirang vexed coated with anti-corrosion/bonding agent INSPECTION DATE: May 21s', 2009 FINDINGS: Activities are satisfactory COMMENTS: 1) Additional damage uncovered at columns, beams, retaining wall Wor walkway slab (see photos, page 2) 2) All repairs this Inspection Report utilized BASF Emaco P24 anti- corrosion/bonding agent 3) Vector Galvashield XP+ sacrificial anodes installed (see Project drawings & specifications) 4) Project drawings will be revised at Project's end to reflect "as -repaired" conditions including supplemental repairs as noted herein Sincerely, V.J.GERUEVAND ASSOCIATES Certified: Victor J Gerley, PE Florida Spec.ins . #89, Prof.En r. #21422 distrib: Charlie Andrews Gen.Mgr., Turtle Reef Club (via email) Victor J. Gerley, PE V.J.Gedey & Assoc. (Project file) Scott A. Lorraine, PE Scott A. Loraine, PE, LLC (Project file) 1 ,,- /, �J • , Field Coordination: Scott A. Lorraine, PE Florida Prof.Engr. #38714 F- jw -0 Inspection Report #16 — Photos are for representative purposes only as noted in captions Supp. repair #1078 (roof edge Unit 509) June 15U', 2009 Permit # 0810-0190 ST. LUCIE COUNTY PUBLIC WORKS DEPARTMENT CODE COMPLIANCE DIVISION 2300 Virginia Avenue Fort Pierce, Florida 34982-5632 STRUCTURAL EMOMEERS 3190 N.E. MAPLE AVE JENSEN BEACH, FLORIDA 34957 TEL 772 334-2600 FAX 772 334-2603 INSPECTION REPORT NO.17 PROJECT:' Turtle Reef Club Condominium II 2008 Building "C" Concrete Repairs LOCATION: 10800 South Ocean Drive Jensen Beach, Florida 34957 CONTRACTOR: Daniello Construction, Inc., CGC #020612 AREA INSPECTED: Repairs # 32C, 60D, 107B, 108, 108B (per Project Drawings S4, S5, & S6 - Supplemental Repairs denoted w/ suffix'13% 'C', etc.) • Satisfactory formwork to repair limits verified • Satisfactory repair mortar patching/placement after form removal verified • Repair area deemed acceptable for stucco repair (shoring removed) INSPECTION DATE: June 3`d, 2009 FINDINGS: Activities are satisfactory COMMENTS: 1) Additional damage uncovered at columns, beam, retaining wall, Wor walkway slab (see photos, page 2) 2) All repairs this Inspection Report utilized BASF LA40, HBA Repair Mortar, or 3500psi ready -mix as applicable 3) Vector Galvashield XP+ sacrificial anodes installed (see Project drawings & specifications) 4) Project drawings will be revised at Project's end to reflect "as -repaired" conditions including supplemental repairs as noted herein Sincerely, V.J.GERLE D ASSOCIATES Certified: Victor J.G dey, PE Field Coordination: Scott A. Lorraine, PE Florida Spec.lnsp. 9, Prof.En r. #21422 Florida Prof.Engr. #38714 distrib: Charlie Andrews Gen.Mgr., Turtle Reef Club (via email) Victor J. Gerley, PE V.J.Gerley & Assoc. (Project file) Scott A. Lorraine, PE Scott A. Lorraine, PE, LLC (Project file) 1 Inspection Report #17 — Photos are for representative purposes only as noted in captions Supp. repair #1088 (roof edge & partial overhead Unit 510)